Skip to content
MouseMouse

Cutting swing amplitude 40% raised yaw-momentum demand 53% - the falsified fix is recorded so nobody walks that road again

A lesson the Coach cites as amplitude-cut-falsified-yaw-fix.
Mechanism understoodEvaluation

Test gait fixes against the quantity the ground must actually supply (torque/force rates vs friction ceilings), not against kinematic proxies; record falsified fixes with their mechanism so the search space shrinks permanently.

Symptom

Support-foot yaw slip stayed at ~223 deg (vs 225 deg) after walk_v6 cut joint swing amplitudes by ~40% (hip_pitch 20.6->10.4 deg, knee 31.3->18.8 deg) - the change built on the theory "smaller swing = less yaw momentum to dump into the ground".

Context

Direct measurement inverted the theory: yaw-momentum amplitude ROSE 16% (+/-0.1000 -> +/-0.1159) and its rate of change rose 53% (1.86 -> 2.84 N*m demanded from the ground), pinned exactly at the foot's supply ceiling (2.8-3.3 N*m at mu 0.6-0.7) - so slip could not drop. The extra demand lives in higher harmonics: v6's crisper foot placement (better clearance 34 mm, lower landing force) shortens the momentum- exchange window, concentrating the same exchange into less time. The verdict was written as a closed road: "下一轮不要再走这个方向". An honest residue was also booked: WHY amplitude down but momentum up 16% remained unresolved, with the named next step (per-rigid-body decomposition of H_z, since per-joint RMS sensitivity ignores phase correlations).

Change

The "reduce amplitude to reduce yaw momentum" lever was removed from the planning space; future yaw-slip work redirected toward the supply side (friction) and momentum-rate mechanics.

Outcome

Slip unchanged (225 -> 223 deg); the falsification and its mechanism became a permanent constraint on the fix search space.

Mechanism

Ground yaw torque demand scales with the rate of change of angular momentum, not its amplitude; kinematic amplitude cuts that also sharpen contact timing can raise dH/dt while lowering range. When demand exceeds the friction-limited supply ceiling, slip is set by the ceiling, so demand-side changes below the ceiling do nothing visible.

Applies when

  • attacking foot slip or yaw drift via gait shape changes
  • a fix targets an amplitude while the constraint is a rate
  • documenting a failed intervention after a version comparison
“walk_v6 | ±0.1159 (+16%) | 2.50 Hz | 2.84 N·m (+53%) … 脚的供给上限 2.8~3.3 N·m(μ 0.6~0.7)—— v6 正好顶在天花板上, 所以滑移一点没降。… 结论: "减小摆动幅度以降低偏航动量"这条被 v6 证伪 —— 砍 39% 幅度, 需求反升 53%。下一轮不要再走这个方向。”
train/WALK_DIAGNOSIS.md § ② 未生效的机理: 减小摆动幅度反而让偏航需求上升

Principles that cite it