Bracket a real-robot A/B with a repeated reference run - battery drain is the confound
battery-bracketed-real-ab.Order hardware A/B sessions as A-B-A: repeat the first condition at the end, and void the comparison if the bracket runs disagree - never let battery or venue drift ride on the second condition.
Symptom
In a two-policy teleop A/B on hardware, the second policy is measured on a lower battery voltage than the first - a systematic bias that would be read as a policy difference.
Context
C2 real A/B (checkpoint 700 vs A800, same floor, same day) was scripted as 700 -> A800 -> 700-rerun, with the explicit note that a teleop session drains the pack and the trailing policy "naturally suffers".
Change
Protocol: run the reference policy first AND last; if the two reference runs differ noticeably, declare the whole session battery/floor-polluted and void the A/B ("结论作废重来"). Also log electricity per run.
Outcome
Called out as the round's only systematic confound, closed by one extra command ("这是本轮唯一的系统性混淆源,一条命令就能堵掉").
Mechanism
Battery voltage scales available torque, and torque loss hits behavior asymmetrically (see power-scale-hurts-nonforward-axes), so drain masquerades as policy regression; a head/tail reference pair converts the unobserved drift into a measured control.
Applies when
- comparing two policies or settings on hardware in one session
- any sequential hardware evaluation where the plant drifts (battery, temperature, floor wear)
“为什么要 700 复跑:一次遥控 session 下来电池会掉压,第二枚天然吃亏。头尾各跑一次 700,若两次 700 明显不同,说明这轮 A/B 被电量污染,结论作废重来。这是本轮唯一的系统性混淆源,一条命令就能堵掉。”