Skip to content
MouseMouse

A frame-history observation under zero DR memorizes the trainer's plant fingerprint - the estimator must see variation to learn estimation

A lesson the Coach cites as history-obs-needs-plant-variation.
Mechanism understoodSim-to-real

If the observation carries history (stacked frames, RNN), keep at least minimal plant variation (gain/latency jitter) on from the first iteration - "nominal first, robust later" is structurally invalid for estimator-bearing contracts.

Symptom

omni_s1 (fresh 215-dim contract with a 5-frame history window, trained with DR fully off): training all green, yet the MuJoCo gate scored 0/20 on all eight doors - falls within 2 s, seven checkpoints, not one transferred.

Context

The history window exists precisely to let the actor implicitly estimate line velocity and actuator dynamics (the actor is denied base_lin_vel by observation honesty). Under a constant plant that implicit estimator has nothing to estimate - it learns the trainer's exact response fingerprint instead, and any other simulator's micro-differences are out-of-distribution: "5 帧窗按设计就是隐式估计器, plant 恒定时它学到 Isaac 精确响应的指纹". The planned "nominal-first-robust-later" staging was declared STRUCTURALLY incompatible with history observations: "估计器要见过变化才学估计, 否则学背诵" (an estimator must see variation to learn estimation, otherwise it learns recitation). Honest confound note kept: this is mixed with "zero DR does not transfer, period" - but both attributions prescribe the same fix, so no control was run.

Change

S1.1: minimum actuator jitter turned on from day one - kp/kd +/-10%, latency 0-1 frame (friction/COM/mass still nominal, no push - those stay for the S2 ladder).

Outcome

Transfer restored: survival 0/20 -> 20/20, speed 19/20, foot distance 20/20 (remaining failures moved to gait quality, a different disease); the staging doctrine was amended - history-carrying contracts never train under a frozen plant.

Mechanism

A recurrent/history channel fits whatever temporal structure minimizes loss; with a deterministic plant the cheapest structure is the plant's own impulse-response signature, yielding features that are simulator-specific rather than physics-general. Plant variation forces the channel to carry state-estimation features that transfer.

Conflicts

Attribution is explicitly confounded with the simpler "zero DR never transfers" reading ("与「零 DR 本身就不迁移」混杂 … 两种归因处方相同, 不做对照") - the source chose not to spend a control run separating them.

Applies when

  • adding frame stacking or recurrence to an actor observation
  • a nominal-plant policy fails a cross-simulator gate within seconds
  • planning DR staging for a new contract
“frame_hist × 零 DR = plant 指纹过拟合——5 帧窗按设计就是隐式估计器, plant 恒定时它学到 Isaac 精确响应的指纹, MuJoCo 的微小差异即 OOD, 2 s 内摔, 七个 checkpoint 无一迁移。「先标称后鲁棒」的分段与历史观测结构性冲突:估计器要见过变化才学估计,否则学背诵。”
train/OMNI_V0_SPEC.md § 3. S1.1 修订记录 ①

Principles that cite it