Knee swing collapsed because it directly trades against the slip penalty - price the conflict explicitly and clamp what reward cannot hold
knee-swing-vs-slip-pricing.When a behavior collapses as another metric improves, look for the term pair trading them and set their price ratio deliberately (with escalation and reverse tripwires pre-registered); where the policy actively spends action budget to undo your target, stop paying more reward and clamp the target space structurally.
Symptom
Knee peak-to-peak swing collapsed across generations - v5 33 deg, v10 26-30, v10b 7-8, v11 6.5-8.6 - and rolling the clock back did not recover it, acquitting the clock; the collapse tracked the gated slip penalty instead: "屈膝与不打滑在当前奖励里直接对抗" - v10b's excellent 93 deg slip was purchased with knee amplitude.
Context
Reward-side flexion fixes had failed three times: raising reference amplitude backfired twice (v9/v11), and v11's deep-squat default was actively fought by the policy - it spent 0.68 of action budget pulling the squat straight ("被策略花 0.68 动作拉直反杀"). v12's design accepted the conflict as real and attacked on two tracks: (1) ECONOMICS - a direct knee_swing_amplitude reward (+0.3, target 0.55 rad, capped at 0.6/step = 55% of tracking), explicitly opposed to the slip penalty by design ("显式对立——这正是设计:v12 就是这场对抗的定价实验"), with an escalation ladder (K +0.3 -> +0.5, then slip -0.5 -> -0.3, one layer at a time) and a reverse tripwire (slip telemetry back at v10 levels -> slip weight to -0.8, accept ~20 deg knee compromise); (2) STRUCTURE - knee target bounds [0.2, 0.9] rad so full straightening is physically impossible (straightest 11.5 deg) and the 0.68 fighting budget is released. A bonus falsifiable prediction was attached: phase-lock strength tracks amplitude (v9_probe 48 deg locked 2.5 Hz; v11 low-amplitude 1.36 Hz unlocked), so if K works, hardware phase-lock should return - one change, two verdicts.
Change
knee_swing_amplitude reward + knee target clamp + pre-registered escalation/reverse levers; the failed reward-side-only approach retired.
Outcome
The lineage was frozen before v12 trained (strategic reset), but the diagnosis stands as the walk line's clearest example of two reward terms trading a behavior between them, with the pricing experiment and structural clamp fully designed and calibrated.
Mechanism
When two terms price opposite aspects of one motion (swing amplitude creates yaw momentum that becomes slip), the optimizer settles wherever the price ratio puts it - patching one side moves the equilibrium, not the conflict. Explicit pricing makes the trade a designed quantity; structural clamps remove the regions where the policy spends budget fighting the designer.
Conflicts
The pricing experiment (K vs slip) was designed and calibrated but never trained - the 2026-08-05 reset suspended v12; the collapse attribution table and the 0.68-action counterattack are measured, the remedy's效果 is untested.
Applies when
- one gait quality degrades in lockstep with another's improvement
- the policy visibly fights a default pose or reference
- repeated reward-side fixes for the same behavior have failed
“膝摆塌在 v10→v10b,头号嫌疑是门控滑移罚(四代实测膝 p2p:v5 33° / v10 26~30° / v10b 7~8° / v11 6.5~8.6°;退时钟没救回 → 非时钟)——"屈膝"与"不打滑"在当前奖励里直接对抗 … 奖励侧修屈膝已三败 … v11 深蹲 default 被策略花 0.68 动作拉直反杀”