Skip to content
MouseMouse

No parameter tuning on the floor - a failing config retries once, then it is out; anomalies go back to sim

A lesson the Coach cites as no-field-tuning-protocol.
ReplicatedSim-to-real

Hardware time is for executing and measuring the pre-registered matrix, never for tuning: failing configs get one retry then elimination, anomalies get recorded and reproduced in sim, and contract-check bypass flags stay unused.

Symptom

Hardware sessions create pressure to fix problems live - nudge a gain, tweak a scale - which destroys attribution and risks the robot.

Context

The anomaly-handling section of the acceptance sheet is three fixed plays: (1) falls at start -> retry once at the same settings; falls again -> that configuration is eliminated, "不现场调参" (no on-site parameter tuning); (2) limit cycle or motor screech -> stop immediately, record the gain level and the joint, reproduce in sim before any discussion; (3) systematic disagreement with sim -> record it as a finding (hardware outranks sim) rather than adjusting anything to force agreement. Related guardrails elsewhere in the sheet: never pass --allow-unstamped / --allow-plant-drift to bypass manifest checks - if it errors, something real is wrong, stop and look.

Change

Field sessions restricted to executing the pre-written matrix; every fix path routed through sim reproduction and the normal config/rung process.

Outcome

Sessions stayed interpretable (each run matched a documented config) and safety overrides never became habit; anomalies arrived back in sim as reproducible cases instead of half-remembered floor stories.

Mechanism

Field-tuned values are measured under adrenaline on one floor with no logging or baselines - they contaminate the config lineage and are unattributable afterwards; and every bypass flag that skips a contract check converts a designed safety property into an operator promise.

Applies when

  • a config fails or oscillates during a hardware session
  • someone reaches for a live gain tweak or a bypass flag
  • writing the anomaly-handling section of a deployment runbook
“起步即摔 → 换档重试一次, 仍摔则该档出局, 不现场调参。出现极限环/啸叫 → 立刻停, 记录档位与关节, 回 sim 复现再议。… 不要给 --allow-unstamped / --allow-plant-drift —— 三枚 ONNX 都已盖章 … 真要报错说明有别的问题, 停下来看。”
train/REAL_RUN_S2.md § 4. 异常处置