The smoke watcher panicked at the wrong operating point and its score goes blind when gates saturate - treat it as a survival sentinel, not a judge
smoke-watcher-operating-point.Configure every automated evaluator at the lineage's declared deployment operating point, give it graded metrics that cannot saturate, and until then scope its authority to catastrophe-detection - never let a mis-configured watcher stop or rank a rung on its own.
Symptom
Two watcher misfires in one ladder: (1) during the friction rung the watcher (evaluating at kd 1.0) reported panic-level 1/3 survival from iter 3300 - falsified by the official kd 1.2 scan, because the lineage's design operating point was kd 1.2 and the watcher lacked the --kd-scale passthrough; (2) during the PD rung the watcher's early-stop score froze at iter 1050 despite ongoing drift improvements, because with all eight gates passing (constant 0/3 failures) the score has no gradient left - "八门全过恒 0/3 时 score 对漂移改善盲, s1f 课文三现".
Context
Both are the same category: the in-training smoke loop is an instrument with its own configuration (operating point, score design), and its verdicts are only as aligned as that configuration. The booked doctrine: "冒烟只当存活哨兵" - until the watcher evaluates at the deployment operating point with graded metrics, its role is detecting catastrophes, not ranking checkpoints; ranking belongs to the full battery at the design operating point (and the watcher's scoring was separately patched to weight survival 3x so recoveries during hard phases are not early-stopped away).
Change
Watcher debt booked (--kd-scale passthrough); score saturation acknowledged with graded columns planned; selection authority kept with 20-seed batteries at the declared operating point.
Outcome
A false panic did not abort a rung that was actually passing at its design point; a frozen score did not hide real drift gains; the instrument's authority was scoped to what its configuration can actually see.
Mechanism
An evaluator is itself configured (gain profile, delay, metrics); evaluating a policy away from its design operating point measures a counterfactual robot, and bounded scores saturate once binary gates pass, losing all sensitivity. Instruments need the same operating-point discipline as deployments and graded outputs to retain gradient.
Applies when
- an automated smoke loop contradicts the official battery
- early-stop scores freeze while graded metrics still improve
- lineages with non-default deployment gain/delay profiles
“watcher (kd1.0 口径) 3300 起 1/3 恐慌被 kd1.2 正式扫描证伪为考纲外假象 —— 工作点评测口径教训: watch_ckpt 缺 --kd-scale 透传 (待补), 冒烟只当存活哨兵。… watcher score 饱和误停 @1050(八门全过恒 0/3 时 score 对漂移改善盲, s1f 课文三现)”