Skip to content
MouseMouse

The deploy-side walk/recovery switch - into recovery at tilt > 65 deg held 0.3 s, back at tilt < 15 deg with angular rate < 1 rad/s and straight knees held 1 s, a 15 s timeout, last action cleared both ways - and the handoff steps the design required are only partly implemented

A lesson the Coach cites as walk-recovery-fsm-handoff.
Observed onceSim-to-real

Specify a deploy-time controller switch as hysteretic, time-filtered predicates the robot can measure (proxy what it cannot, e.g. straight knees for height), a timeout that ends in a safe stop, and a complete handoff (history, clock, last action, command ramp) - then test that the code performs every handoff step, because the design document is not the implementation.

Symptom

With a recovery policy and a locomotion policy as separate networks, the robot needs a switch: when is it "fallen", when is it "up", and what state must be reset so the next policy does not act on the previous one's history.

Context

The 08-09 design: enter recovery when fallen (tilt > 55 deg or height < 0.60 x 0.384 m) for 150 ms, leave for a stand-hold when upright (tilt < 12 deg, height > 0.85 x 0.384 m, feet steady, |omega| < 0.8) for 400 ms - wide entry, strict exit, hysteresis - then a mandatory handoff trio before walking resumes (reset the walking policy's observation history, restart its phase clock at 0, clear its previous action and latency buffer) and a command ramp instead of a jump. The 08-14 implementation in deploy_policy (--recovery-policy): each policy under its own manifest contract (walk: nominal + scale; recovery: beta-anchored), the same rl_default gains, the tilt cutoff disabled; RECOVERY at tilt > 65 deg for 0.3 s; LOCO again at tilt < 15 deg and |omega| < 1 and knees straight (< 0.35 rad) for 1 s - the robot's computer has no height estimate, and straight knees stand in for height so a V3.0-style upright kneel cannot pass as standing; RECOVERY longer than 15 s ends in a safe stop; last_action cleared on both switches; command forced to 0 during RECOVERY; power scaling applies to LOCO only.

Change

An open account was written down with it: the recovery end state (0.355 m stance, hip yaw -/+27 deg) is outside the walking policy's training start distribution, so the first test must use stand / zero command as LOCO, and the long-term fix is to widen the walking policy's initial states rather than bend recovery's stance to suit walking.

Outcome

The spec records only a successful compile (py_compile); the hang test was left to be done on site. The operator runbook carries the three-step procedure (hang with stand as LOCO, mat and push, then omni walk as LOCO) but no outcome.

Mechanism

Two policies trained separately each assume their own history, clock and last action; a switch that carries any of them across feeds the next policy a state it never saw - the design called this "the walking policy seeing a ghost history".

Conflicts

The 08-09 design requires resetting history, clock and previous action plus a command ramp; the 08-14 implementation records last_action clearing and a zero command during recovery; the one-leg spec of 2026-09-14 lists the handoff hygiene as specified but not implemented - reset_history() is called by nothing (a 215-dim policy would carry four frames of pre-fall history), the phase clock is not zeroed, and there is no command ramp back to LOCO. No hardware run of the FSM is recorded in either source.

Applies when

  • switching between separately trained policies on hardware
  • a policy with history or phase observations is re-enabled mid-run
  • the robot lacks a sensor the switching criterion was designed around
“**判据**:进 RECOVERY = 倾角 >65°(`--fall-tilt-deg`)持续 0.3 s;回 LOCO = §5 真机可测子集:倾角 <15° ∧ |ω|<1 ∧ **膝直 <0.35 rad(NX 无高度观测, 高度门用膝直代理 —— 防 V3.0 型"跪坐但直立"误判)** 持续 1 s (`--recover-hold`);RECOVERY 单次 >15 s(`--recovery-max-time`)安全停。 … **切换卫生**:两向切换 last_action 清零;RECOVERY 态 cmd 强制 0”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §50 FSM 双策略调度(2026-08-14,用户令):deploy_policy --recovery-policy

Principles that cite it