Skip to content
MouseMouse

The recovery line's real-robot verdicts live in three places that disagree - the spec's "fairly stable, first real stand-up" for v2_6, an undated runbook note that only v3_1p1c works, and a first run whose details were never recorded

A lesson the Coach cites as write-hardware-verdicts-back.
Observed onceSim-to-real

A hardware verdict is a dated entry in the authoritative ledger - policy file and stamp, gain profile, floor, battery, tries, log file, what was seen - written back the same day; a note in a command file is a pointer, not a verdict, and a newer verdict that contradicts an older one must say so.

Symptom

Asked "which recovery policy works on the real robot", the sources give different answers, and none of them carries the conditions of the test.

Context

08-09: the first real run was stopped as violent and dangerous; which ONNX, which gain profile and whether a log existed were marked "to be recorded" and never were. 08-11: v2_6 was "fairly stable", the line's first real get-up, with splits after standing; v2_5b's result and both CSVs were "to be reported". 08-14: v3_1p1c was stamped and pushed, with "the real first test still needs the user present"; the spec records no hardware result for it. The operator runbook (undated) puts above the v2_6 and v2_5b floor commands the note that none of the recovery policies below work, only recovery_v3_1p1c - a verdict never written back into the spec, with no date, floor, battery, number of tries or log attached.

Change

None recorded in the sources; this card records the gap.

Outcome

The line's authoritative record ends with v3_1p1c as the product awaiting its first real test, while the operator's note implies it is the only one that works and that v2_6 (recorded as a success) does not.

Mechanism

Verdicts given at the robot travel by word of mouth and command-file comments; without a record carrying the conditions, a later reader cannot tell a changed verdict from a changed floor, battery or stack.

Conflicts

§43 (2026-08-11) records v2_6 as the first successful real get-up ("fairly stable"); the undated runbook says every recovery policy except recovery_v3_1p1c does not work; §49 (2026-08-14) says v3_1p1c's first real test was still pending. The runbook's claim has no date and was never written back to the spec, so it cannot be ordered against §43.

Applies when

  • choosing which policy to deploy from an operator's notes
  • a hardware session ends without a written result
  • two documents disagree about what worked on the robot
“下面的recovery都不行 只有recovery_v3_1p1c.onnx”
RL系统/FOLLOW THIS copy 2.md § #### Recovery Policy (operator runbook, undated)

Principles that cite it