Skip to content

It walks sideways, where its parent barely moved, at 120% and 125% of the commanded speed. Both overshoot the test's 115% limit. It passes 5 of 13 sim tests. A reflex policy for Lucen Biped.

for Lucen Biped50 HzIsaac Labiteration 800
Lucen Biped, the robot this policy is for

Runs in your browser · about 11 MB the first time

1 of 1 sim test passes

Every seed stayed upright in all 1.

Measured on this hub in MuJoCo: 1 of 1 test pass · 3 seeds, 20 s each. A test passes when every seed stays upright and tracks 85–115% of the command.

TestResult
Forward 0.25 m/sspeed 93%Pass

Speed, sideways and turn are the share of the command the robot reached.

Published with the policy, tested . Open the sim test

Forward 0.25 m/s, on lucen/laika. Tested . Published with the policy.

How it was trained

Isaac Lab, iteration 800: 100 iterations past laika-omni-c2-700, exported 2026-08-08. Its training run is private, so no curve is published.

README

README.md

laika-omni-c4-ff800

It walks sideways, where its parent barely moved, at 120% and 125% of the commanded speed. Both overshoot the test's 115% limit. It passes 5 of 13 sim tests.

LineWalking in any direction
What changedA new controller contract: a sideways feed-forward term in the joint targets, and a sidestep command.
CheckpointIteration 800, 100 iterations past laika-omni-c2-700.
In simulationPasses 5 of 13 sim tests. Fails on backward speed, sideways speed, turning and forward speed.
On the real robotDeployed
Exported2026-08-08

Plant it was trained against

Full values in the Files tab
Torque limitRS00 11 N·m, RS02 17 N·m, RS06 12 N·m
Velocity limitRS00 33 rad/s, RS02 20 rad/s, RS06 10 rad/s
ArmatureRS00 0.0015, RS02 0.0032, RS06 0.007
Joint frictionRS00 0.13, RS02 0.12, RS06 0.15
Joint damping0.02
Default stiffness and dampingRS00 12 and 0.6, RS02 20 and 1, RS06 30 and 1.5
URDF and USD fingerprintsd6fab96bfc280a4d and 92b141c8dd200483

If the robot's motors differ from these, the simulator warns and the real robot refuses the policy.

Sim tests

Measured in simulation. 13 commands, 20 seeds each.

A command passes when every seed stays upright for the whole run and tracks 85% to 115% of the command. A check passes at 20 of 20 seeds.

TestResultReading
Stand stillPass20 of 20 upright
Forward 0.15 m/sPass20 of 20 upright, 89% of the commanded speed
Forward 0.30 m/sPass20 of 20 upright, 93% of the commanded speed
Backward 0.10 m/sFail20 of 20 upright, 132% of the commanded speed
Backward 0.20 m/sPass20 of 20 upright, 97% of the commanded speed
Sideways left 0.10 m/sFail20 of 20 upright, 120% of the commanded sideways speed
Sideways right 0.10 m/sFail20 of 20 upright, 125% of the commanded sideways speed
Turn left 0.20 rad/sFail20 of 20 upright, 75% of the commanded turn rate
Turn right 0.20 rad/sFail20 of 20 upright, 58% of the commanded turn rate
Forward 0.20 m/s, turn left 0.20 rad/sFail20 of 20 upright, 95% of the commanded speed, 82% of the commanded turn rate
Forward 0.20 m/s, turn right 0.20 rad/sFail20 of 20 upright, 93% of the commanded speed, 16% of the commanded turn rate
Forward 0.15 m/s, sideways left 0.10 m/sPass20 of 20 upright, 95% of the commanded speed, 89% of the commanded sideways speed
Forward 0.15 m/s, sideways right 0.10 m/sFail20 of 20 upright, 78% of the commanded speed, 116% of the commanded sideways speed

Real robot

Deployed. Feedback from the robot was traced to the remote control's speed settings.

Where it comes from

Lucen Robotics trained this policy for Lucen Biped in Isaac Lab. The inputs, outputs and plant come from the ONNX file's own stamp. The sim tests, where there are any, come from the training log's results.