Training Coach
Doctrine
A report may cite any of these as doctrine-N.
doctrine-1Contract freeze and fingerprint disciplineThe policy I/O contract (observation layout, scales, history semantics, action pipeline) is frozen and fingerprinted; every exported policy is stamped and verified; contract changes ship as new versioned profiles that leave old artifacts bit-identical, and old policies run forever under their era's pinned profile.
Case. The 215-dim omni contract was frozen with a three-machine digest; the one contract-level extension (lateral feed-forward) went in as a new `omni_ff` profile with the old profile provably untouched, and the contract checker caught two real wiring bugs before any training (`contract-freeze-and-checker`). A silently changed gait-clock default would have fed old policies a 25% slower clock - closed by pinned legacy profiles (`legacy-profile-pinning`). A stale derived USD forked plant mass 2.2% until an automated source-vs-derived instrument gated it (`derived-asset-staleness-check`). A gain profile is part of the closed loop a policy was trained in and belongs in its stamp; the recovery line's anchored authority was left out of its manifest and recorded as the gap not to repeat (`gain-profile-belongs-in-the-stamp`), and a second policy behind a deploy-side switch made the handoff state itself a contract (`recovery-two-policies-and-a-state-machine`, `walk-recovery-fsm-handoff`).
Coach application. On any proposal touching obs/action semantics, defaults, or derived assets: demand the version/profile plan, the fingerprint update, and the checker extension in the same change; flag any old artifact that would run under new defaults.
doctrine-2Attribution by resolved training params - never eval-override knobsCapability differences between lineages are explained only by digging each lineage's *resolved* training configuration and eliminating columns; evaluation-side override knobs (kd-scale, power-scale, cycle-time) act on the plant for *every* policy and may serve as deployment mitigations but never as explanations.
Case. Low-friction robustness across 8 lineages x 3840 cells was traced to kd DR *bandwidth* - every lineage had ground friction pinned to (1.0,1.0), so "trained friction" could not be the axis; the parameter axis and the plant axis were explicitly separated after the first attribution conflated them (`kd-bandwidth-mu-law-attribution`). "Weak turning" on hardware was a power-scale plant effect, not a training gap (`deploy-knob-attribution-before-retraining`); slowing the deploy clock was out-of-distribution, not a feature (`cycle-time-override-is-ood`). The ground truth for what a run trained under is the logged per-run config, not the source tree (`resolved-config-is-source-of-truth`).
Coach application. Whenever asked "why is lineage A better", require the resolved-param table first; kill zero-variance columns; refuse explanations phrased in eval-knob terms; when a knob helps, label it deployment mitigation.
doctrine-3PASS gates become constraints; FAIL gates become objectivesOnce a skill passes its gate, that gate converts into a standing regression constraint (budget <= 2/20 against the parent baseline) for all later training; gates currently failing are the only legitimate objectives of the next rung.
Case. The C ladder ran one frozen 13-cell x 20-seed matrix at every rung with promotion = "new skill PASS and old skills within regression budget"; C1 was stopped and re-rooted precisely because it trained away the root's backward PASS (`fixed-acceptance-matrix-per-rung`, `preregistered-stop-criteria-per-rung`). The C4 product shipped only at 260/260 cells with zero regression.
Coach application. Keep the ledger: every PASS adds a constraint row; propose rungs only against FAIL rows; treat any constraint violation as stop-and-attribute, never "the next rung might win it back".
doctrine-4One variable per ladder rung - counted against what the checkpoint sawA rung changes one variable, where "one" is counted against the checkpoint's actual training state, not against the current config's diff; batching is allowed only when each change owns a disjoint symptom space with a pre-registered ablation order.
Case. Two rungs failed identically because resuming s1e-500 under the evolved config silently added four plant variables the checkpoint had never seen ("单变量纪律不只看「我改了什么」,还要看「checkpoint 见过什么」" - `resume-state-dr-audit`). v8 legally batched four orthogonal fixes with a written ablation order (`orthogonal-batch-with-ablation-order`); v9 spent one run completing a 2x2 factorial so either outcome convicted a factor (`fill-the-missing-factorial-cell`); v10b's three-way ablation wrongfully convicted the clock and had to be retried fairly.
Coach application. Before any resume: diff cfg against the checkpoint's logged training state. Before any batch: require the symptom-ownership map and ablation order in writing.
doctrine-5Pre-register risks, readings, and stop criteria before the ladderBefore a ladder or risky rung, write down the known risks, the interpretation of every plausible outcome, and hit-any-one stop criteria - frozen before training, tightened when priors say results should come fast.
Case. The C ladder opened with three numbered risks including the exact falsification condition for its own root choice; A/B arms carried "预注册读法(事后不改)" tables; a level expected to fail was run anyway for its pre-registered diagnostic value (`preregister-risks-and-fork-readings`). Stop criteria caught C4-redo rungs at +200 instead of full caps (`preregistered-stop-criteria-per-rung`); hardware sessions pre-registered per-config expected signatures and the disagreement rule "不改结论改账" (`preregistered-real-expectations`, `feasibility-accounts-lock-design-point`).
Coach application. Refuse to open a rung without the written risk/reading/ stop block; after results, read conclusions off the pre-registered table and flag any post-hoc reinterpretation.
doctrine-6Plant parameters are measured, never inventedEvery plant number carries measurement provenance: armature = N^2 x rotor inertia from no-load tests, friction split by rig and by API column, torque limits shaped by per-joint gait peaks, latency traced through the real pipeline, masses weighed - and DR bands are additive around the measured nominal, sized to the measured dispersion.
Case. Guessed friction was 2.5x low and guessed damping 5x high (`friction-measured-not-guessed`); armature had been 0 with a 9:1 gearbox (81x reflected inertia, `armature-n2-rotor-inertia`); a uniform torque derating was "the wrong shape" vs measured peaks (`torque-limit-shape-by-measured-peaks`); the delay implementation itself was a wrong plant for a whole lineage (`latency-lerp-reverse-extrapolation`); the run design point was locked by three accounts including the tau_limit/kd speed ceiling (`feasibility-accounts-lock-design-point`); identified friction had to land in the right simulator API columns to act at all (`sim-api-friction-columns`). The recovery and one-leg lines opened with the same kind of accounts before any reward existed - a connected static path and the torque along it for an armless get-up, and the gains single support needs to be holdable at all (`get-up-feasibility-accounts-before-training`, `single-support-gain-authority-probe`).
Coach application. For any plant value in a config review, ask "measured how?"; reject absolute ranges with no nominal; check API column mapping and derived-asset regeneration whenever measured values land.
doctrine-7Sim2sim gate before sim2real - under deployment conditionsEvery checkpoint passes a second, independently built simulator before hardware, and both the gate and the smoke loop run under the measured deployment conditions (real pipeline delay, honest contact parameters, the deployment gain/power profile).
Case. The standing order "先sim2sim 再sim2real" (`sim2sim-gate-before-sim2real`); acceptance flipped to match hardware only under measured condim/torsional friction (`eval-plant-honesty-contact-params`); gates moved permanently to `--delay 2` after the kicking incident (`pipeline-latency-is-plant-not-dr`); and the harness itself must be audited - a frame-convention bug in the cross-sim evaluator invalidated a whole line of verdicts (`body-frame-velocity-api-audit`). The recovery line's second simulator caught a torque penalty paid for by bracing the legs together (`torque-penalty-bought-by-leg-bracing`), and a 1.8x torque disagreement between the two plants stayed binding because its one surviving explanation was never tested (`torque-disagreement-between-simulators-unresolved`).
Coach application. Block any hardware request lacking a second-sim PASS at deployment conditions; when sim2sim and training-side metrics disagree, treat the evaluator as a suspect too.
doctrine-8Observation honesty - the actor's inputs are a hardware contractThe actor observes only signals the real robot produces with realistic noise; privileged truths go to the critic; history windows are estimators and must train under plant variation; rewards on quantities the actor cannot observe buy only average suppression, never closed-loop correction.
Case. Ground-truth velocity/forces went critic-only (`observation-honesty-critic-only`); frame_hist under zero DR memorized the trainer's plant fingerprint - 0/20 transfer (`history-obs-needs-plant-variation`); world-frame yaw rewards could not teach pull-back because heading is unobservable to the actor - correction was routed to the deploy outer loop instead of breaking the contract (`reward-observability-limit`, `deploy-heading-loop-and-align-training`).
Coach application. Audit every actor-obs element for hardware existence; require minimal plant jitter whenever history/recurrence exists; for each reward, ask "can the actor see this error?" and route correction tasks to outer loops.
doctrine-9Reward economics are audited in realized currencyReward design decisions are made on realized per-step magnitudes under the actual policy and command distribution: price the do-nothing optimum before adding a mode, compare achieved values to the computed ignore-floor, calibrate thresholds between measured healthy and sick distributions, and ship every new penalty with a withdrawal clause.
Case. feet_air_time at weight 2.0 realized 0.038 vs tracking 1.2 - drag was rational (`realized-contribution-audit`); ignoring a vy command cost 28-180x less than ignoring vx until a gated tracking term was added (`reward-cost-of-ignoring-audit`, `gate-new-reward-terms-by-command`); achieved-vs-floor separated "never learned" from "priced out" (`ignore-floor-diagnosis`); the foot-distance wall was placed between measured healthy (0.6% tax) and sick (55%) policies (`calibrate-threshold-between-healthy-and-sick`); the landing penalty carried a pre-registered stand-down condition and actually stood down (`calibration-threshold-with-withdrawal-clause`); two clearance terms were inert until zero-points and gate occupancy were checked (`inert-reward-term-audit`). A get-up policy sat because three gated terms paid the seated pose 84% of the return and the one term that could tell sitting from standing was an exp kernel reading 4.6e-5 at the real error (`seated-basin-dead-exp-kernel`); a torque-tail term was weighted by its measured steady value beside a peer term after the estimate proved 12x off (`tail-torque-needs-hinge-on-computed-demand`).
Coach application. Never discuss weights in the abstract: demand the realized-contribution table, the ignore-floor number, and the healthy-pay calibration before any reward edit is approved.
doctrine-10The zero-cost option must be the desired behaviorFor every penalty, name what the zero-cost option is; penalize failure events (slip, saturation excess, contact in flight windows), never the motion or joints that healthy behavior uses; make degenerate strategies fatal via termination where penalties cannot price them out.
Case. Joint-usage penalties for drift taxed a 1.4%-of-momentum channel 2.7/step and collapsed training; the slip penalty costs a non-slipping gait exactly zero (`penalize-the-slip-not-the-joint`). A frozen-at-clamp joint pays zero action-rate forever - only a pre-clip saturation penalty flips the cheat economics (`saturation-cheating-zero-rate-cost`). Ungated phase shaping made standing 42x more expensive than stepping and cooked the hip motors (`moving-gate-42x-stand-tax`); crouch-shuffling lived until a height termination deleted it (`termination-closes-degenerate-basin`). A gated penalty is an exit: the policy parked just outside an uprightness gate, then just under a height gate, to stop paying a stance tax, and only a positive band plus an always-on guard closed both (`penalty-gate-is-an-escape-hatch`); a soft-limit penalty that charged the standing pose itself bought a 4.1 deg lean (`soft-limit-penalty-charges-nominal-pose`); an unpriced foot attitude was spent on edge-standing (`unpriced-foot-attitude-is-a-free-variable`); and the one-leg line listed its cheapest cheats before training and still met one through a zero-gradient band (`enumerate-cheapest-cheats-before-training`, `binary-band-reward-fake-touchdown`).
Coach application. Run the "零代价的选项是什么" audit on every proposed term; convert motion taxes into event-conditional penalties; check the termination set against each known degenerate strategy.
doctrine-11Measurement discipline: independent referees, signs, distributionsA disputed measurement is adjudicated only by an independent algorithm from raw state; directional ability requires sign-antisymmetry under command reversal; bimodal metrics are reported as mode shares (never medians, never 3 seeds); ratios are not comparable when totals change; reward values compare only within one command distribution; single chaotic events never cross machines.
Case. The triple reversal - a good metric was "refuted" by a sibling metric that shared the disease (`independent-referee-for-metric-disputes`, `body-frame-velocity-api-audit`); same-signed +/- responses were bias, not turning (`same-sign-response-is-yaw-bias`); the swing median sat in a bimodal gap (`median-hides-bimodal-distribution`); "v6 is jitterier" died on absolute energies (`ratio-metrics-need-absolute-check`); yaw gain measured 15x wrong in an oscillating frame (`heading-integral-not-body-rate`); a 44% improvement evaporated under same-distribution comparison (`same-distribution-reward-comparison`); drift direction was a limit cycle (`multiseed-sign-test-for-drift`); a cross-machine push cliff was chaos (`single-impulse-recovery-is-chaotic`).
Coach application. Before accepting any surprising number: ask for the independent recomputation, the sign pair, the distribution shape, and the comparison conditions. Retract in writing when a metric falls.
doctrine-12The deployment pipeline is plantIrreducible pipeline properties - action latency, rate limits, power/torque scaling, teleop command mappings - are part of the nominal plant, modeled from day one and reproduced in every gate; deploy-side scalings are crutches that flag unmodeled plant, and they cannot be algebraically folded into training constants.
Case. Right-leg kicking was over-trained-delay x loop gain; power 0.8 was a gain-reduction crutch that retired when the delay was modeled (`pipeline-latency-is-plant-not-dr`); power derating damages non-forward axes first (`power-scale-hurts-nonforward-axes`); training at 0.4 scale as the "twin" of deploying 0.5 x 0.8 collapsed 0/20 (`deploy-scaling-not-training-equivalent`); one shared teleop speed sent an out-of-band lateral command and the robot clipped its own foot (`teleop-command-band-per-axis`); the latency DR range had not even covered the measured pipeline (`latency-dr-covers-measured-pipeline`). A rate limiter added at deployment only clipped a policy that kept commanding (`deploy-rate-limiter-windup`); moved into training and anchored on the last command it became an integrator in the balance loop (`slew-anchor-is-an-integrator`); anchored on the measured angle it bounded torque and kept the bandwidth (`beta-anchored-action-target`). The walking lines' safe setting, power-scale 0.8, cut the ends of the recovery policy's full-range travel and left its spikes alone; a gain inside the trained band did the job (`power-derating-cuts-full-range-contract`).
Coach application. Demand the measured pipeline latency/limits in the plant model and in gate conditions; treat every deploy-side derating as a question ("what is this compensating?"); block per-axis command sources that exceed training bands.
doctrine-13DR budget is finite; its distribution is the measured supportRobustness is a conserved budget: disturbance training on an already-hardened lineage borrows from existing margins; DR ranges span the measured deployment support - no fictitious tails (they buy degenerate gaits), no single constants (they allow thin-margin specialization); harden the plant only after the task distribution is final.
Case. The same push dose helped a narrow lineage and damaged a balanced one - budget conservation (`push-dr-conditional-budget-conservation`); wide latency tails bought drag-glide, constant values shipped 60% thinner tilt margins - the answer is a narrow band on the measured support (`dr-tail-plant-continuation`, `constant-value-dr-overfits-margin`); task-first ordering because hardening a soon-to-change task wastes budget (`task-shaping-before-plant-hardening`); COM randomization used deliberately as a behavior-shaping tool, and rolled back on symptom per its own contract (`com-randomization-forces-leg-spread`, `com-dr-rollback-on-symptom`). DR that is switched on can still be thin: the run policy fell in the frontal plane its gain-and-latency randomization never touched (`thin-dr-judged-by-channel-coverage`), and a friction priority settled under one action contract had to be re-measured under the next (`friction-priority-re-measured-after-plant-change`).
Coach application. Before any DR rung: check the untrained policy against the spec, the lineage's current DR load, and the measured real-world range; after it: audit retained margins, not just the new tolerance.
doctrine-14Gates measure what hardware feels: posture, margins, stripped assistsAcceptance batteries carry posture-class rows (tilt max median, per-joint L/R asymmetry, temperature) beside task rows, graded margin columns beside binary gates, chirality scored per side, at least one condition that removes the environment's free stabilization, and validated predictive scalars promoted into the gate.
Case. Three same-shaped judging errors - survival, displacement, wz-difference - all missed what the operator felt; posture metrics had the predictive power (`task-metrics-vs-posture-metrics`, `stand-gate-posture-not-survival`); binary survival saturated and hid a 60% margin gap (`constant-value-dr-overfits-margin`); v5 passed everything on the ground and failed suspended (`suspension-probe-removes-free-stabilizer`); the hip_roll (l+r) scalar predicted real drift direction and ordering and entered the battery (`hip-roll-sum-predicts-lateral-drift`); averages hide chirality (`chirality-scored-separately`); gait-quality gates are judged at speeds that demand a gait (`low-speed-commands-reward-dragging`). The recovery line added the rest of the kit: where failed episodes end, not only where they started (`end-state-confusion-matrix`); a frozen acceptance distribution with a pinned seed (`frozen-acceptance-distribution-and-pinned-seed`); video of the metric rollout itself (`video-as-acceptance-record`); and the admission that a 10 s episode cannot see a stance that fails after a minute (`episode-length-bounds-what-a-gate-sees`). The one-leg line removed a foot-spacing wall that no gate measured, and the feet met on hardware (`removed-wall-returns-on-hardware`).
Coach application. Review every battery for posture rows, margin columns, per-side scoring, and an assist-stripped condition; when operator feel and gates disagree, suspect the metric class first.
doctrine-15Fork and root selection: recoverability, maturity, frozen rewardsChoose fork roots by which candidate's deficits the coming training can pay back (precision is recoverable; lost plasticity, symmetry, and margins are not); prefer mature checkpoints as roots even when younger ones score better as products; never fine-tune through a reward change - continuation is legal only with the reward frozen and plant/DR widening one rung at a time.
Case. s1e-500 beat higher-precision candidates because its exclusive strengths were unrecoverable (`fork-root-recoverable-shortfall`); the b300 arm proved maturity is capital against adaptation shock (`root-maturity-vs-product-quality`); the B-arm scatter/half-recover/collapse signature falsified reward-change fine-tuning and drew the legal boundary for S2 continuation (`fine-tune-reward-change-falsified`).
Coach application. For root debates, build the exclusive-strengths table and ask "which side can be trained back?"; require dual-arm evidence for maturity claims; classify any proposed continuation as reward-frozen or not before approving.
doctrine-16Curricula: verified engagement, lineage counters, disease-phase gatingAutomatic curricula must prove they engage (a saturated ratchet is constant DR wearing a curriculum's name); every ramp counts lineage-cumulative progress, not per-process steps; penalties aimed at late-stage pathologies ramp in after exploration noise decays; difficulty rises on measured per-stratum success, never on schedule.
Case. The s1f ratchet capped at iter 248 and never engaged (`auto-curriculum-engagement-check`); the saturation ramp re-fired at +600 after every resume and no shipped product ever saw the penalty (`curriculum-counter-lineage-steps`); the same penalty worked once gated to the disease phase and became an untouchable mechanism (`gate-penalties-to-the-disease-phase`); record-high aggregate reward hid a fully-failing delay stratum (`aggregate-metrics-mask-subgroup-failure`); bucket share is not a gradient lever (`bucket-share-is-not-a-gradient-lever`). An assist curriculum keyed to a pooled success share was withdrawn on the strength of the categories that already worked (`curriculum-criterion-conditioned-on-lagging-category`); a pace set by per-step income moved only when that income was time-gated (`per-step-income-drives-speed-time-gate`), and the same gate had to be retired in a lineage without the disease (`time-gate-vs-wide-stance-retire-the-fix`).
Coach application. Ask every curriculum three questions: does it engage (show the internal state)? what does it count (process or lineage)? when is it present (against the pathology's phase)? Check where shipped checkpoints sit relative to every ramp.
doctrine-17Probe before training: feasibility first, hypotheses in tablesAfter two failed training attempts at a skill, stop training: demonstrate the behavior open-loop, enumerate hypotheses in a written table audited against actual configs cheapest-first, race one probe per side of the sim2real boundary for hardware-only pathologies, and use suspended tests to acquit or convict actuators before blaming authority.
Case. "在黑暗里试钥匙" - four sidewalk rungs failed until an open-loop probe separated exploration/waveform/authority in one experiment (`open-loop-probe-before-reward-tuning`); the foot-drag mystery fell to a seven-hypothesis config audit (`hypothesis-table-code-audit`); the period-doubling was resolved by racing a reward-side and a plant-side evidence line - and both paid off, one per sub-case (`period-doubling-evidence-race`); the suspended test acquitted the roll actuator in one measurement (`suspended-test-isolates-actuator-authority`). A read-only configuration probe told a wall from a slope in the recovery line's seated basin (`configuration-probe-wall-not-slope`), and the fix it pointed to - where the feet are - took prone from 0/159 to 158/159 (`prone-dead-end-is-foot-placement`); a knob that did not move its variable was recorded as no test of the idea (`dof-vel-penalty-is-not-a-pacing-knob`).
Coach application. When a skill resists training, prescribe the probe before any further reward edits; require verified target trajectories before imitation terms; keep a falsified-fixes list so closed roads stay closed (`amplitude-cut-falsified-yaw-fix`).
doctrine-18External advice is recomputed locally; values transfer as ratiosEvery external suggestion is classified adopt / already-have / modify / trap by recomputing its claim on the local reward table and probe data; numeric values transfer only as dimensionless ratios (to tracking weight, leg length, sqrt(gL), control rate); citations are verified to exist.
Case. "Start vy very small" would have destroyed sidewalk learning on this reward table - the gradient scales quadratically (`external-advice-audit-against-own-arithmetic`); swing-height targets and weights transferred correctly only through leg-length and tracking-ratio scaling (`transfer-ratios-not-absolutes`); the "6-step delay" was refused for lacking a control rate (`latency-dr-covers-measured-pipeline`); a borrowed reference's structure was FK-verified and its amplitude re-derived from the division of labor (`reference-structure-fk-amplitude-division`); retrieval agents fabricated verbatim arXiv quotes - only source-verifiable material was used; and one dismissed suggestion later proved right for a different mechanism, and was credited (`cycle-average-tracking-for-gait-quantities`). An advisor's staged state machine turned out to exist in none of the three papers it cited, and reading them changed the plan (`advisor-paraphrase-vs-paper`).
Coach application. Intercept every "paper X does Y" with the local recomputation; convert absolutes to ratios before comparison; verify quotes; revisit dismissed advice when new mechanisms appear.
doctrine-19Hardware sessions are scripted experiments, not tuning sessionsReal-robot time executes a pre-registered matrix: risk-ordered (baseline first, fragile last with a spotter), stage-gated (suspended smoke before ground), A/B sessions bracketed by a repeated reference run, operators briefed on measured zero-command and untrained-axis behavior, chirality-aware disturbance protocols, no field tuning - the only legal field changes are scripted, single-variable, and self-reversing.
Case. The S2 acceptance sheet (`risk-ordered-real-deployment`, `battery-bracketed-real-ab`, `know-zero-command-behavior`, `push-test-chirality-protocol`, `no-field-tuning-protocol`); the RAM-only torque experiment with automatic power-cycle rollback (`reversible-single-variable-field-experiments`); and the sim-veto rule - even sim's condemnations get one safeguarded hardware check when they judge the purpose-built configuration (`sim-veto-needs-real-confirmation`). The recovery line's first real run went ahead with its preconditions unmet and was stopped as dangerous (`first-real-get-up-violent-stage-one-policy`); after it: a staged hang, mat and floor protocol (`staged-hang-mat-floor-for-get-up`), a fixed power-cycle pre-flight and two-machine discipline (`power-cycle-preflight`, `two-machine-config-discipline`), a fall guard replaced rather than switched off (`fall-guard-becomes-a-state`), and logs that are part of the run (`hardware-log-is-the-attribution-input`).
Coach application. Turn every hardware request into a runbook with order, gates, brackets, briefing, and anomaly plays; refuse improvised parameter changes on the floor.
doctrine-20Close questions in writing; restart when the debt is structuralAudited questions get frozen verdicts with citable wording and an explicit reopening bar; hardware verdicts are dated by deployment-stack and calibration state and expire when those change; and when successive rungs shuffle symptoms without net progress, freeze the lineage as regression baselines, pay the structural debts, and retrain minimal - carrying laws and instruments, not weights.
Case. The chirality and COM questions were closed with frozen wording and "no reopening without new hard evidence" (`frozen-verdicts-semantic-boundaries`); v5/v6's condemnations expired with the deploy stack (`stale-verdicts-under-old-stack`); a 2-degree calibration fix moved the whole runnable envelope (`zero-offset-calibration-shifts-envelope`); plant upgrades are era boundaries with paired re-baselining (`plant-swap-invariants-vs-shifts`); and the 2026-08-05 reset froze v5-v11, fixed the latency FIFO / manifest / sampling / reward-table debts, and restarted - producing the lineage that reached hardware SOTA (`freeze-lineage-fix-structure-restart`, `minimal-reward-table-with-provenance`). The recovery line's real-robot verdicts ended up in three places that disagree, one of them an undated note in a command file (`write-hardware-verdicts-back`).
Coach application. Maintain the closed-questions ledger and quote it when symptoms recur; stamp verdicts with stack/calibration versions; when a team is three rungs into symptom-shuffling, raise the restart question explicitly with the freeze-fix-restart pattern.
doctrine-21Name the quantity in the space it lives inA goal, reward term or acceptance criterion about the feet, the base or the contact state is computed from the quantity itself - world poses, forces, per-category outcomes - never through a joint-angle, single-signal or pooled stand-in that assumes everything else sits at nominal; and every detector is validated on a behaviour known not to contain the event before it becomes a gate.
Case. The recovery line was caught three times: |ankle roll| as "flat feet" sold stance width and the real robot slid into the splits, a hip-roll criterion was confounded by 50 deg of yaw, and the joint table said 0.271 m where the feet were 0.159 m apart; task-space terms produced the first flat, wide stance (`joint-space-proxy-for-task-space-quantity`). Flight detection lied in both directions across two lines - foot height flagged 40% false flight on a walking gait, contact force alone flagged slip chatter as hops (`contact-detector-single-signal-lies`). A pooled height average described a robot that did not exist - six in ten standing, four in ten sitting (`zero-partial-credit-is-not-an-iteration-problem`) - and the walking line had learned the same lesson on yaw rate (`heading-integral-not-body-rate`).
Coach application. For every reward term and gate row, ask what physical quantity it stands for and whether it is measured directly; flag joint-space or single-signal stand-ins for task-space goals, ask for a detector validated on a negative control, and split pooled metrics by category before reading them.
doctrine-22Continuation needs a live gradient; a release is chosen by a scanContinue a converged policy only on a change that creates a live gradient, on a short budget, with every checkpoint scanned on the transfer axis; choose a release by running the full battery over a band of checkpoints and stop on signals, never by taking the last one; and when edits to the terminal phase cannot move a behaviour, roll back and retrain with the constraint present from the start, keeping the order in which the lineage acquired its mechanisms as explicit curriculum phases.
Case. A continuation with no new gradient drifted MuJoCo transfer from 100/98% to 80/28% while every Isaac gate stayed perfect, and a live-gradient continuation at the same depth kept it (`converged-continuation-is-poison`). One-leg checkpoints 100 iterations apart failed 1 and 38 of 40 cells, and late ones degraded (`checkpoint-choice-is-a-full-gate-scan`). Four in-lineage stance fixes failed because the stance was the end of the get-up path, and from scratch it grew right (`stance-decided-by-get-up-path`); fixes stacked on degraded states were rolled back by the user (`stop-stacking-roll-back-and-audit`); and the lineage's final recipe, trained from scratch in one run, sat at 0% because the order of its curriculum was part of the product (`curriculum-history-is-part-of-the-product`). The omni line's short adaptation budgets and mature roots are the same law seen from the other side (`continuation-budget-not-from-zero`, `root-maturity-vs-product-quality`).
Coach application. Before approving a continuation, ask for the new gradient, the budget and the transfer axis in the scan; before approving a release, ask for the scan; after three rungs without progress on the target, propose rolling back to the last good checkpoint and a from-scratch phase plan instead of a fourth patch.
Experience cards
161 cards matching “gate-new-reward-terms-by-command”.
Add a single-point-suspension test to acceptance - the ground is a free stabilizer that hides divergence
suspension-probe-removes-free-stabilizerInclude at least one acceptance condition that strips the environment's free stabilization (suspension, or equivalent) - the sim-passing policy that fails on hardware is often failing a condition the battery never posed.
Symptom
walk_v5 looked healthy in every on-ground sim test yet diverged on the real robot - the acceptance battery had never measured a condition that would have revealed it.
Context
The battery gained a single-point-suspension probe (robot hung, feet free): measure torso tilt while the policy runs without ground contact. v5 scored 45.9 deg mean tilt suspended - wildly unstable - which the file calls "最灵敏的失稳探针(拿掉地面这个免费稳定器)": ground reaction forces passively stabilize a marginal policy, so on-ground metrics saturate long before the policy's internal balance is actually sound. v6 halved it (23.0 deg, target <10 deg) - progress visible on a scale where on-ground numbers showed nothing.
Change
Suspended-tilt added as a standing acceptance row; run under the honest contact parameters battery (accept_v2 with measured condim 4 / torsional friction 0.035), under which v5 correctly FAILS in agreement with the real robot.
Outcome
The sim battery's verdict on v5 flipped from pass to fail, matching hardware; suspended tilt became the discriminating metric between v5 and v6 (45.9 vs 23.0 deg) when ground metrics differed little.
Mechanism
Contact with the ground closes a stabilizing feedback loop the policy gets for free; removing it exposes the policy's own attitude control authority. A metric measured only in the assisted condition cannot rank policies by the unassisted quantity that hardware will actually demand during perturbations and flight phases.
Applies when
- sim acceptance passes but hardware diverges
- designing an acceptance battery for a legged robot
- two candidates tie on ground metrics
“单点吊那条是最灵敏的失稳探针(拿掉地面这个"免费稳定器"), v5 在地上一切正常却在真机发散, 就是因为验收从没测过这个工况。”
train/WALK_V6_MINIMAL.md § 5. 验收 Changing the gait clock silently flipped a hardwired threshold's meaning - write derived constants as expressions
derived-constants-must-track-their-baseBefore changing any base parameter (clock, control rate, scale), enumerate every constant derived from it and every constant that must NOT change; convert derived literals into expressions of the base so the next change cannot silently flip a term's meaning.
Symptom
Slowing the clock 0.40 -> 0.50 s would have silently inverted the feet_air_time threshold's semantics: the 0.25 s threshold was hardwired, so at ct 0.40 the swing window (~0.20 s) sat below it (constant pressure to lengthen strides), while at ct 0.50 the window (~0.25 s) equals it - the term's meaning flips from "push longer" to "neutral" with no code error anywhere.
Context
The clock change audit walked every dependent quantity: most followed automatically (joint_pos_ref / clearance / contact_number cycle_time params, gait_phase observation, deploy/sim2sim/policy_io, export) - wiring confirmed, zero hand edits; the air_time threshold was the one hardwired constant, fixed by preserving the RATIO: 0.25 -> 0.3125 = 0.625 x ct, with the recommendation to commit it as the expression 0.625*ct "一劳永逸" (solved once and forever). The same audit also listed what must NOT follow the clock (50 Hz control rate, physics dt/decimation, 47-dim contract, action_latency absolute seconds, PD/torque limits) - the change's blast radius stated in both directions.
Change
feet_air_time threshold re-expressed as a fraction of cycle_time; auto-following vs must-not-change lists written into the spec for the clock migration.
Outcome
The clock migration (v10, repeated in v11) carried no silent semantic flips; the expression form removed the trap for every future clock change.
Mechanism
Constants derived from a base parameter encode a ratio at their birth; storing the evaluated number severs the dependency, so changing the base leaves stale semantics with no failing test. Expressions preserve the intent; and an explicit both-directions dependency list (follows / must-not-follow) is what makes a base-parameter change reviewable.
Applies when
- changing gait clock, control frequency, or units
- a reward threshold interacts with a phase/window duration
- config audit finds literals that encode ratios
“feet_air_time 阈值 0.25 是写死的,不跟 ct 走——0.40 时摆动窗 ~0.20s<0.25(恒拉长压力),0.50 时摆动窗 ~0.25s≈阈值(语义翻转)。按比例保原压力:0.25 → 0.3125(=0.625×ct;建议直接写成 0.625 * ct 表达式,一劳永逸)。”
train/WALK_V10_SPEC.md § 3. T —— 慢时钟 (训练侧必做一件) The median of a bimodal metric lands in the empty gap - check the distribution, and never judge swing on 3 seeds
median-hides-bimodal-distributionBefore quoting a median or mean, look at the distribution; report suspected-bimodal metrics as mode share plus per-mode ranges, use small-seed smoke runs only to screen trends, and size the seed count for decisions by the share resolution you need (here: 20).
Symptom
Years of "high swing variance" and undecidable 3-seed swing readings turned out to be one fact: the metric was bimodal all along - "历代 swing 高方差与 3-seed 不可判由此定性:一直在测双稳态系统" - and every median reported from it (e.g. 12.1 mm) described a value no seed ever produced.
Context
Concrete instances: s2e_pd-1400's 20 seeds split 2.6-4.9 mm vs 19.3-24.0 mm with zero seeds between; s1e-500 read 3.9 mm on seeds 0-2 but 23.1 mm median over 20 seeds; a 3-seed reading of 19.3 was logged as "double-peak optimism, lesson recurrence #4". The selection re-audit codified the sampling rule: "3-seed 的 swing 读数不可判点, 只能筛带,选点必须 20-seed" - 3 seeds may screen a band, only 20 seeds may pick a point.
Change
Swing (and any suspected multi-modal metric) reported as mode shares plus per-mode ranges instead of a bare median; 3-seed smoke numbers demoted to band-screening; all shipping/selection decisions moved to 20-seed batteries.
Outcome
The "swing debt" bookkeeping was reinterpreted as basin probability (see swing-bistability-damping-switch), and checkpoint selection stopped being whipsawed by which basin the first three seeds happened to fall into.
Mechanism
Central-tendency statistics presuppose unimodality; on a bimodal distribution the median tracks the mode SHARE, not any achievable behavior, and small samples alias the share entirely. Mode-aware reporting (share + per-mode stats) is the only faithful summary, and the needed sample size is set by the share resolution required.
Applies when
- a quality metric shows chronic high variance across seeds
- 3-seed smoke readings contradict 20-seed batteries
- reporting swing height, clearance, or any basin-prone metric
“中位数落在空档里,「swing 债 −11mm」实为「50% 概率掉进拖地吸引子」。历代 swing 高方差与 3-seed 不可判由此定性:一直在测双稳态系统。… swing 跨 seed 双峰 (500 在 seed0~2 只读 3.9mm, 20-seed 中位 23.1) —— 3-seed 的 swing 读数不可判点, 只能筛带, 选点必须 20-seed。”
train/README.md § swing 双稳态定性 / s1e 选点重审 A soft joint-limit penalty charged the standing pose itself - the geometric-zero knee sat on its hard limit, so stand_v1 bent its knees to dodge 0.419 per step and leaned 4.1 deg forward; excluding the knee gave 0.24 deg
soft-limit-penalty-charges-nominal-poseBefore training, evaluate every penalty at the nominal pose; if a joint's soft limit sits inside the pose the task requires (a straight knee on its hard stop), exclude that joint from the soft-limit penalty and let the action clip enforce the hard limit.
Symptom
stand_v1 (retrained after the default pose moved to the CAD geometric zero and mirror augmentation was added) fixed left/right asymmetry (6.8 -> 0.0 deg) but settled at a 4.1 deg forward lean, where pure PD at the same default settled at 0.1 deg - the policy was actively pushing itself forward, which is exactly the real robot's failure direction.
Context
soft_joint_pos_limit_factor = 0.9 shrank the knee's soft limit to -/+0.1047 rad, while the geometric-zero default has the knee at q = 0, exactly on the hard limit. Standing in the nominal pose therefore paid 0.2094 x 2.0 = 0.419 per step in dof_pos_limits (alive earned only 0.5). The policy's way out was to bend the knees to -/+0.1013 rad, and the cost was the forward lean.
Change
stand_v1b: the knees excluded from dof_pos_limits (a straight knee IS the standing pose; the hard limit is still enforced by the action clip). No other change.
Outcome
stand_v1b: max tilt 0.3 deg, steady tilt 0.24 deg, asymmetry 0.1 deg, height 0.384 m - exactly nominal - with knees at -0.0007 / +0.0005 rad. It became the standing release used on the real robot, and later the standing side of the recovery switch. The same exclusion was carried into the recovery contract (knee at the clip in the standing pose) and the one-leg reward table.
Mechanism
A limit penalty whose soft boundary lies inside the nominal pose turns the nominal into a taxed state, and the policy buys its way out with whatever posture change is cheapest - here a knee bend paid for with lean.
Applies when
- a standing or default pose has a joint at or near its hard limit
- a policy settles in a small steady tilt that pure PD does not show
- soft-limit factors shrink limits uniformly across joints
“`soft_joint_pos_limit_factor=0.9` 把膝软限位内缩到 ∓0.1047,而几何零位 default **膝盖 q=0 正好压在硬限位上** ⇒ 站在标称姿态每步白扣 `0.2094 × 2.0 = 0.419` (alive 才 +0.5)。策略只能屈膝到 ∓0.1013 躲罚,代价是躯干前倾 —— 恰好是真机的 失效方向。 … 修掉"软限位罚标称姿态"后重训(`dof_pos_limits` 排除膝盖)。**前倾问题彻底消失** … 不再屈膝躲惩罚,高度正好落回标称 0.3840。”
train/README.md § 三期: 镜像对称增强 + 站立 v1 (2026-07-28) / stand_v1b (2026-07-28): 站立定版 Deployment power derating damages non-forward axes far more than forward - sweep it in sim before deploying
power-scale-hurts-nonforward-axesTreat deployment power/torque scaling as a plant parameter: evaluate the policy in sim at the exact deployment scale, expect non-dominant axes to degrade first under derating, and either deploy at the training power or train with power randomization.
Symptom
Policies deployed at power-scale 0.8 (a safety derating of commanded torque) looked fine walking forward but were weak at backward and turning, inviting the wrong diagnosis "the skill was not trained well".
Context
Measured repeatedly: on s1e, going 1.0 -> 0.8 cost forward 18% but backward 58%; on C4-ff800, turn tracking was +25%/+40% at pw0.8 vs +75%/+58% at pw1.0, backward 51-52% vs 97-103%, while forward stayed 96-98% at both. Sim evaluation numbers in the plan were all pw1.0, but the robot was being run at 0.8.
Change
Pre-deploy protocol added: sweep the exported policy across power in sim (for PW in 0.8 0.9 1.0: eval_c_matrix --power $PW --seeds 20) and deploy at the first level where both turn directions reach >=50%. For C4 the recommendation was raise the robot to pw1.0 - the sweep showed it nearly free (saturation 47%->33%, left foot-clipping danger zone 25%->6%, cost only tilt 6.7->8.3 deg).
Outcome
Turning "weakness" resolved without any retraining; the sim sweep correctly predicted the real-robot signature at both power levels.
Mechanism
Forward walking is the reward-dominant, torque-cheapest skill with the most margin; backward/turn/sidewalk live closer to the torque envelope, so a uniform torque derating consumes their margin first. Training ran at power 1.0 (the trainer does no power scaling), so deploying at 0.8 is a systematic underactuation the policy never experienced.
Applies when
- deploying with any torque/power derating or safety scale
- secondary skills (backward, turn, lateral) underperform on hardware while forward walking looks fine
- choosing the deployment power level for a new policy
“power 衰减对非前进轴的伤害远大于前进轴(s1e:前进 1.0→0.8 掉 18%,后退掉 58%)。转向是非前进轴,0.8 下很可能明显跟不动。”
train/C_LADDER_RUN.md § 3c. A-2 上机前先定部署力度档 / 3p. 二 A hardware run without its log is an anecdote - the first real get-up's policy, gain profile and log were never recorded, two CSVs stayed "to be reported", and runbook commands wrote different policies' logs under one copied filename
hardware-log-is-the-attribution-inputMake the log part of the run: name it from the policy and conditions automatically (never by hand-copied filenames), record the policy digest and gain profile inside it, include what the open questions need (torque, joint positions and targets), and treat a session without a collected log as incomplete.
Symptom
The recovery line's oldest open question - whether Isaac or MuJoCo reads torque demand correctly - was waiting on real-robot logs that never arrived, and the verdicts that did arrive could not be tied to files.
Context
deploy_policy writes a CSV per run (--log); the runbook's own analysis snippet reads its joint-position, target and action columns (q_, tgt_, act_), and the recovery hanging checklist asks for torque and joint logs for the whole run, to be compared with simulation. The first real get-up (08-09): policy, gain profile and log "to be recorded later". The first real A/B (08-11): v2_5b's result and both policies' CSVs "to be reported". In the runbook's walking commands, three runs of two different c4 policies log to real_s1e_pw08_teleop_0808.csv, and s1e and s2e_fric runs log to real_c2_700_pw08_teleop_0808.csv - filenames copied from other commands.
Change
None recorded; the spec kept listing the open-loop comparison as waiting for real logs.
Outcome
No real-robot log appears in the recovery spec through §50, so the simulator disagreement stayed unresolved and hardware verdicts stayed unattached to data.
Mechanism
Attribution needs the run's identity (policy digest, profile, conditions) and its signals in one artifact; a filename copied from another command mislabels the file, and a log not collected at the session is rarely collected later.
Applies when
- planning a hardware session whose result should settle a sim question
- log filenames are typed or pasted by hand
- hardware feedback arrives as prose without files
“python tools/deploy_policy.py --policy train/policies/omni_c4_ff800_pj.onnx … --log train/real_logs/real_s1e_pw08_teleop_0808.csv … q,t,a=d[:,c("q_")],d[:,c("tgt_")],d[:,c("act_")]”
RL系统/FOLLOW THIS copy 2.md § Walk 遥控 / S2 / csv 分析片段 (operator runbook, undated) Multiple changes may share one rung only if their symptom spaces are orthogonal - with the ablation order written in advance
orthogonal-batch-with-ablation-orderBatch changes into one rung only when you can name each change's private symptom space in writing; pre-register the ablation order (numeric before structural) and per-change escalation plans, so a mixed outcome decomposes without new decisions.
Symptom
v8 needed four repairs at once (saturation cheating, landing impact, leg narrowing, heading alignment) - strict one-variable laddering would have cost four training cycles for wounds that were all already diagnosed.
Context
The batch was allowed because each change owns a disjoint symptom space, stated explicitly: "A→形态/饱和, B→落地/步态高度, C→腿距/roll 摇摆, D→偏航/转向" - so a single run can attribute each outcome to its change by which symptom moved. For the failure case, the ablation order was pre-registered (A2 -> A1 -> B -> D -> C, "先撤数 值改动" - retract numeric tweaks before structural ones), and every change carried its own escalation/rollback plan (e.g. A insufficient: joint_pos_ref 1.6->2.0 or widen the exp kernel; B overdone - robot afraid to land: v_ok 0.30->0.45; D unstable: rel 0.5->0.25, not back to 0).
Change
Four-change rung executed as one run with per-change symptom ownership, per-change contingency plans, and a pre-registered global ablation order for unattributable regressions.
Outcome
The rung retained single-run attributability without paying 4x training cost; the contingency table meant no failure mode would require improvising an ablation under pressure.
Mechanism
The one-variable rule exists to keep attribution possible, not as an end in itself; attribution survives batching exactly when the changes' observable effects are separable. Orthogonality is a claim that must be argued per pair in advance - and the pre-registered ablation order is the escape hatch for the case the claim fails.
Applies when
- several diagnosed fixes are queued and ladder time is scarce
- deciding between strict laddering and a combined rung
- a combined rung shows a regression no single change explains
“四个改动症状空间基本正交,可单 run 归因:A→形态/饱和,B→落地/步态高度,C→腿距/roll 摇摆,D→偏航/转向。出现无法归因的整体退化时消融顺序 A2→A1→B→D→C(先撤数值改动)。”
train/WALK_V8_SPEC.md § 8. 风险与归因 A suspended (no-load) test acquits or convicts the actuator before you blame authority
suspended-test-isolates-actuator-authorityBefore attributing a failure to actuator authority, measure no-load tracking error and steady-state torque fraction; blame authority only if the task fails while the error grows with demanded force - and then fix gains or targets, not training.
Symptom
hip_roll sagged 0.21 rad on the ground and saturation questions loomed over the sidewalk plan - was the roll axis physically too weak (authority), or was something else limiting it?
Context
Before C4, the roll-authority question was settled by measurement triage: suspended test (--suspend, feet off ground) showed hip_roll tracking error 0.0008 rad - actuator acquitted; the entire 0.21 rad ground sag is load-induced. Steady-state torque was 25% of limit - 75% margin remains. Since sidewalk needs lateral force, not exact angles, authority was ruled "not a hard limit", with a pre-registered criterion for when it WOULD become one: sidewalk fails to track AND roll error keeps growing - then the fix is raising hip_roll kp or lowering the vy target, not more training.
Change
Hypothesis "roll authority insufficient" demoted from blocker to a monitored branch with an explicit trigger condition; C4 proceeded.
Outcome
Later open-loop probes confirmed the actuator could produce the behavior (sidewalk feed-forward ran at full amplitude, 5/5 survival), and the eventual C4 failure causes were measurement and reward, never authority.
Mechanism
Suspended vs loaded comparison separates the actuator's closed-loop competence from the load path: tiny no-load tracking error means the motor/controller is fine and any loaded deviation is statics (gravity / stiffness budget, kp trading error for force). Torque-fraction measurement then bounds how much force headroom actually remains.
Applies when
- suspecting an axis is "too weak" for a new skill
- large position sag on a loaded joint
- deciding between hardware fix, gain change, and more training
“吊挂(--suspend)实测 hip_roll 跟踪误差 0.0008 rad → 执行器无罪,地面下垂 0.21 rad 全是负载所致;稳态占限扭 25% → 仍有 75% 扭矩余量。… 判据:若 C4 出现「侧走跟不动且 roll 误差继续变大」,那才是权限账 … 解法是提 hip_roll 的 kp 或降 vy 目标,不是硬训。”
train/C_LADDER_RUN.md § 3d. roll 权限:已部分澄清,不是硬上限 Close a question with an audit, then freeze the wording - later symptoms may not reopen it without new hard evidence
frozen-verdicts-semantic-boundariesWhen an audit closes a hardware-vs-policy question, record the closing evidence, freeze a citable wording for future recurrences, and set the reopening bar explicitly; separate robustness perturbations from plant-truth questions so a DR rung's failure can never silently reopen a closed measurement.
Symptom
Recurring directional bias on the robot kept re-suggesting "maybe the hardware/COM/mechanics are asymmetric", threatening to re-litigate questions that audits had already closed - burning attention each time a descendant policy leaned or drifted.
Context
Two boundary decisions were written as permanent: (1) semantic separation - "S2④ COM ±20mm = 纯鲁棒性扰动,不再承担「解释真机后仰」任务" - if the COM-DR rung degrades, the ONLY allowed conclusion is "policy insufficiently robust to COM uncertainty"; reopening "is the CAD COM wrong" is forbidden because the mass audit was completed and closed (@63f9212). (2) a frozen wording for chirality, to be quoted verbatim whenever left/right bias appears in later rungs: observed directional bias = policy-level spontaneous symmetry breaking; plant asymmetry = no supporting evidence after the mass + model symmetry audit; mitigation candidate pi_sym queued, not blocking. The evidential basis was quantitative: the root policy was perfectly symmetric under +/-6 N*s pushes (40/40) while descendants broke (17/40, 13/40) - "手性是 S2 训练中获得的, 根没有; 机械侧已双 PASS 关案, 不重开".
Change
Closed questions carry (a) the audit commit that closed them, (b) a frozen citable wording for recurrences, and (c) an explicit evidence bar for reopening ("无新硬证据不得重开").
Outcome
Later chirality observations (C2's 15 pp turn gap, hip_roll drift bias) were handled as policy-lineage properties with policy-side mitigations, without a single hardware re-audit cycle.
Mechanism
Symptom classes recur under different guises; without a frozen verdict each recurrence re-runs the same expensive investigation and risks a different (worse-informed) conclusion. Freezing verdict plus wording converts recurring symptoms into citations, while the evidence bar keeps the closure honest rather than dogmatic - the root/descendant symmetry comparison is what makes "it's the training, not the machine" checkable at any time.
Applies when
- a recurring symptom keeps suggesting an already-audited hardware cause
- writing conclusions for a completed calibration/audit
- a DR rung's degradation invites re-measuring the plant
“若 S2④ 退化,结论只能是「当前 policy 对 COM 不确定性不够鲁棒」,不得重开「CAD COM 是不是错了」… 手性冻结表述 … Plant asymmetry: no supporting evidence after mass + model symmetry audit … 无新硬证据不得重开机械不对称”
train/OMNI_V0_SPEC.md § 4. 语义分界与手性冻结表述(2026-08-07 用户定,永久) An auto-curriculum ratchet capped out at iter 248 and never engaged - stage difficulty manually or verify engagement
auto-curriculum-engagement-checkPrefer manually staged difficulty with gated transitions; if you use an automatic curriculum, instrument its internal state and alarm when it stops engaging - a saturated curriculum is constant DR wearing a curriculum's name.
Symptom
A curriculum mechanism intended to grow difficulty adaptively (s1f's ratchet) hit its cap at iteration 248 and never bit again - for 96% of the run its effect was equivalent to constant DR, i.e. the curriculum existed in name only.
Context
When external advice suggested graded wz bands (start ±0.15, then ±0.30), the team agreed with grading but explicitly rejected automatic curriculum, citing the s1f episode. The same logic had already been paid for with push grading: ±0.6 failed twice, ±0.3 was feasible - grading matters, but the grade transitions were made by hand at verified checkpoints.
Change
Ladder policy: difficulty staged manually, one band per rung, each transition gated by the acceptance battery; automatic ratchets not used unless their engagement is monitored and demonstrated.
Outcome
Every C-ladder band change (wz ±0.12-0.25 first, wider later) was an explicit, attributable rung; no silent constant-DR-in-disguise runs recurred.
Mechanism
Adaptive curricula couple their own state machine to noisy training metrics; a ratchet that saturates early stops adapting but keeps its name, so the operator believes difficulty is progressing when it is frozen. Manual staging costs more decisions but each decision is observable and reversible.
Applies when
- choosing between auto-curriculum and staged bands for a new skill
- a curriculum's difficulty parameter plateaus early in training
- post-hoc attribution of what difficulty a lineage actually saw
“C2 的 wz 分级(±0.15 → ±0.30,不要一上来 ±0.6)—— 与我们付过学费的 push 分级同形(±0.6 两轮 FAIL,±0.3 才可行)。但必须手动分级,不做自动课程 —— s1f 的课程化棘轮 iter 248 封顶未咬合,96% 时长等价常量 DR”
train/C_LADDER_RUN.md § 1. 采纳 3 条 (C2 的 wz 分级) Measure yaw rate by integrating heading, not by averaging body-frame angular velocity - the two differed 15x
heading-integral-not-body-rateFor any secular rate (turn gain, drift), integrate the world-frame angle over the window; never average instantaneous body-frame rates during oscillatory motion - and when code comments warn about a measurement, believe them before re-measuring.
Symptom
Two measurements of the same turn gain disagreed by a factor of ~15: time-averaged body-frame omega_z gave -0.05 while the sim2sim harness's heading-angle integration gave +0.473.
Context
The harness code comment had already documented and predicted the failure: during gait the torso oscillates (body-frame omega_z std up to 0.7); projecting world angular velocity onto a swaying body axis and then averaging biases the estimate systematically - "实测体系均值 −0.04 而实际在以 +0.15 转" (measured body-frame mean -0.04 while actually turning at +0.15). The author's own -0.05 measurement was declared void and the training machine's 1.58/2.45 turn gains confirmed valid.
Change
Measurement doctrine fixed: yaw rate for evaluation = net heading change by integration over the window; instantaneous body-frame rates are unusable for averaged directional statistics during legged gait.
Outcome
Subsequent friction sweeps and turn-gain accounting were all conducted in the heading-integral currency, making cross-simulator comparisons (MuJoCo vs Isaac 1.04/1.02) meaningful.
Mechanism
Averaging a vector quantity expressed in an oscillating frame couples the frame's oscillation into the mean (a rectification bias); the heading integral is computed in the world frame where the gait oscillation integrates to ~zero, leaving the secular component.
Applies when
- measuring turn gain, heading drift, or any secular angular rate
- a body-frame-averaged statistic disagrees with trajectory-level truth
- writing evaluation code for oscillating platforms
“我用体坐标系 ωz 的时间均值测,得 −0.05;sim2sim 用航向角积分,得 +0.473。差 15 倍。… 步态中躯干摇晃(体系 ωz std 可达 0.7),把世界角速度投到摇摆的体轴上再取均值会系统性偏掉 … 结论:偏航率必须用航向积分,体系瞬时角速度取均值不可用。”
train/WALK_DIAGNOSIS.md § ③ 转向增益 —— 我的测法是错的,训练机的 1.58/2.45 成立 Record where every failed episode ends - an end-state confusion matrix showed all failures finishing seated and overturned a "cannot roll over" diagnosis that per-category success rates hide by construction
end-state-confusion-matrixFor any multi-category acceptance, report where each failed episode ends, not only which category it started in; it costs a few lines and no extra simulation, and it separates "cannot reach the goal" from "reaches the wrong basin".
Symptom
Prone scored 0% for three generations; the working diagnosis was "prone lacks the roll-over skill", and R0.3 spent a run adding prone-to-side roll-arc start states. It bought nothing: the 45-deg roll band itself only moved from 24.2% to 26.6% after 3,000 iterations.
Context
Acceptance reported success per starting category. A final-state table (lying prone / on the side / supine / seated / standing for every failed episode) was added to accept_recovery.py at R0.3.
Change
The confusion matrix became a permanent part of the acceptance output, and the prone diagnosis was rewritten from it.
Outcome
The prone, side and supine columns were all zero - every failure ended seated - and prone had righted its torso in 159/159 episodes (tilt under 30 deg in 100%). The missing ability was standing up from one specific seated configuration, not rolling over, which redirected the next rungs to foot placement and to a configuration probe.
Mechanism
Per-category success rates collapse "reached the wrong basin" and "never reached anything" into the same zero; the end state separates them.
Applies when
- a category sits at 0% and the diagnosis rests on its label
- recovery, manipulation or navigation tasks with distinct terminal states
- an intervention aimed at the presumed cause shows no effect
“**① 末态混淆矩阵 —— 固化(已在 `accept_recovery.py`)。** 它给出的 "趴/侧躺/仰躺三列全 0、所有失败都终于坐姿"是本线最改变决策的一个事实, 而**逐类成功率按构造看不见它**。 … 成本十来行、零额外仿真。 … **② prone 病因更正(旧诊断作废)。** 旧:"缺翻身"。新:**prone 159/159 全部 把躯干翻正**”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §15 R0.3 判决 + 三件事的判断 Low-friction robustness traced to kd DR bandwidth, not friction training - by digging resolved params across 8 lineages, 3840 cells
kd-bandwidth-mu-law-attributionAttribute capability differences by tabulating every lineage's resolved training params and eliminating zero-variance and non-aligned columns first; never let an eval-side override knob serve as the explanation axis, and never write a mechanism into a law before it survives a targeted test.
Symptom
Lineages differed wildly in low-ground-friction survival, and the intuitive explanation - "some trained ground friction, some didn't" - was about to steer the ladder toward a ground-mu training rung.
Context
The attribution ran as a full parameter-vs-result cross: 8 lineages x 4 eval kd levels x 6 mu levels x 20 seeds = 3840 cells, with each lineage's RESOLVED training params dug out and compared item by item. First kill: all 8 lineages had ground mu pinned at (1.0,1.0) - zero variance - so low-mu differences cannot come from friction training at all. The only training parameter aligned with the mu score was kd DR bandwidth: narrow (<=0.24) lineages scored 19.9/19.5/19.5, wide (>=0.40) scored 17.1/15.2/14.6/14.2/12.8 - the two groups completely non-overlapping. Every rival was excluded item by item (kd center no; kp band no; COM small-beneficial non-driving; friction rung a clean double null 19.5->19.5 and 15.2->14.6; iteration count non-monotonic), and the one clean single-variable causal link confirmed it: the s2e-3 kd surgery (0.7,1.3)->(1.08,1.32) moved the score 17.1->19.5. Counter-proof against "each best at its own operating point": the narrow-band lineage evaluated OUT of band (18.2) still beat the wide-band lineage at its own band center (9.2). Two axes were ordered never to be conflated (the first attribution's own error): training kd bandwidth is a parameter axis / lineage property; the eval-side --kd-scale knob is a plant axis (more damping physically helps on slippery floors for ALL policies) - "plant 轴只能当部署缓解,不能当 归因". A tempting mechanism story ("drag vs step attractor") was tested and falsified, and explicitly kept OUT of the law: "机制未定, 不入定律".
Change
The planned ground-mu training rung was recommended closed ("建议 不开") in favor of a kd band-narrowing rung (0.8,1.2)->(0.9,1.1) centered on the deployed value - with a pre-registered risk that the law demands "bandwidth = measured dispersion" and the real robot's kd dispersion was not yet measured; if it exceeds +/-10%, narrowing sacrifices real coverage and the rung must yield.
Outcome
A whole training rung was deleted from the ladder by attribution alone (the second S2 pass dropped mu and push, 5 rungs -> 3); floor material became a deployment-selection input (mu <~0.6 -> deploy the kd1.2 gain profile) rather than a training target.
Mechanism
Cross-lineage performance differences must be attributed over the actual training-parameter table, not over eval knobs or plausible stories: eval knobs act on the plant for every policy (a physical effect), while lineage properties come only from training-time parameters. Zero-variance columns are free eliminations, and one clean single-variable rung is worth more than any correlation.
Applies when
- explaining why lineages differ on a robustness axis
- an eval-side knob (gain scale, power) changes results and invites misattribution
- deciding whether to open a DR rung for an axis never actually varied in training
“8 血统地面 μ 训练带全部钉 (1.0,1.0) 零方差,低 μ 差异与「训没训地面摩擦」无关,是 kd DR 带宽的副产物 … 宽 ≤0.24 → 19.9/19.5/19.5;宽 ≥0.40 → 17.1/15.2/14.6/14.2/12.8, 两组完全不重叠。… 训练 kd 带宽 = 参数轴/血统属性;评测部署 --kd-scale = plant 轴 … plant 轴只能当部署缓解, 不能当归因。… 机制未定, 不入定律。”
train/OMNI_V0_SPEC.md § 4. 地面 μ 鲁棒性 = kd DR 带宽的副产物 (2026-08-08) The smoke watcher panicked at the wrong operating point and its score goes blind when gates saturate - treat it as a survival sentinel, not a judge
smoke-watcher-operating-pointConfigure every automated evaluator at the lineage's declared deployment operating point, give it graded metrics that cannot saturate, and until then scope its authority to catastrophe-detection - never let a mis-configured watcher stop or rank a rung on its own.
Symptom
Two watcher misfires in one ladder: (1) during the friction rung the watcher (evaluating at kd 1.0) reported panic-level 1/3 survival from iter 3300 - falsified by the official kd 1.2 scan, because the lineage's design operating point was kd 1.2 and the watcher lacked the --kd-scale passthrough; (2) during the PD rung the watcher's early-stop score froze at iter 1050 despite ongoing drift improvements, because with all eight gates passing (constant 0/3 failures) the score has no gradient left - "八门全过恒 0/3 时 score 对漂移改善盲, s1f 课文三现".
Context
Both are the same category: the in-training smoke loop is an instrument with its own configuration (operating point, score design), and its verdicts are only as aligned as that configuration. The booked doctrine: "冒烟只当存活哨兵" - until the watcher evaluates at the deployment operating point with graded metrics, its role is detecting catastrophes, not ranking checkpoints; ranking belongs to the full battery at the design operating point (and the watcher's scoring was separately patched to weight survival 3x so recoveries during hard phases are not early-stopped away).
Change
Watcher debt booked (--kd-scale passthrough); score saturation acknowledged with graded columns planned; selection authority kept with 20-seed batteries at the declared operating point.
Outcome
A false panic did not abort a rung that was actually passing at its design point; a frozen score did not hide real drift gains; the instrument's authority was scoped to what its configuration can actually see.
Mechanism
An evaluator is itself configured (gain profile, delay, metrics); evaluating a policy away from its design operating point measures a counterfactual robot, and bounded scores saturate once binary gates pass, losing all sensitivity. Instruments need the same operating-point discipline as deployments and graded outputs to retain gradient.
Applies when
- an automated smoke loop contradicts the official battery
- early-stop scores freeze while graded metrics still improve
- lineages with non-default deployment gain/delay profiles
“watcher (kd1.0 口径) 3300 起 1/3 恐慌被 kd1.2 正式扫描证伪为考纲外假象 —— 工作点评测口径教训: watch_ckpt 缺 --kd-scale 透传 (待补), 冒烟只当存活哨兵。… watcher score 饱和误停 @1050(八门全过恒 0/3 时 score 对漂移改善盲, s1f 课文三现)”
train/README.md § omni_s2e_fric (watcher 恐慌被证伪) / omni_s2e_pd (500 臂) Cutting swing amplitude 40% raised yaw-momentum demand 53% - the falsified fix is recorded so nobody walks that road again
amplitude-cut-falsified-yaw-fixTest gait fixes against the quantity the ground must actually supply (torque/force rates vs friction ceilings), not against kinematic proxies; record falsified fixes with their mechanism so the search space shrinks permanently.
Symptom
Support-foot yaw slip stayed at ~223 deg (vs 225 deg) after walk_v6 cut joint swing amplitudes by ~40% (hip_pitch 20.6->10.4 deg, knee 31.3->18.8 deg) - the change built on the theory "smaller swing = less yaw momentum to dump into the ground".
Context
Direct measurement inverted the theory: yaw-momentum amplitude ROSE 16% (+/-0.1000 -> +/-0.1159) and its rate of change rose 53% (1.86 -> 2.84 N*m demanded from the ground), pinned exactly at the foot's supply ceiling (2.8-3.3 N*m at mu 0.6-0.7) - so slip could not drop. The extra demand lives in higher harmonics: v6's crisper foot placement (better clearance 34 mm, lower landing force) shortens the momentum- exchange window, concentrating the same exchange into less time. The verdict was written as a closed road: "下一轮不要再走这个方向". An honest residue was also booked: WHY amplitude down but momentum up 16% remained unresolved, with the named next step (per-rigid-body decomposition of H_z, since per-joint RMS sensitivity ignores phase correlations).
Change
The "reduce amplitude to reduce yaw momentum" lever was removed from the planning space; future yaw-slip work redirected toward the supply side (friction) and momentum-rate mechanics.
Outcome
Slip unchanged (225 -> 223 deg); the falsification and its mechanism became a permanent constraint on the fix search space.
Mechanism
Ground yaw torque demand scales with the rate of change of angular momentum, not its amplitude; kinematic amplitude cuts that also sharpen contact timing can raise dH/dt while lowering range. When demand exceeds the friction-limited supply ceiling, slip is set by the ceiling, so demand-side changes below the ceiling do nothing visible.
Applies when
- attacking foot slip or yaw drift via gait shape changes
- a fix targets an amplitude while the constraint is a rate
- documenting a failed intervention after a version comparison
“walk_v6 | ±0.1159 (+16%) | 2.50 Hz | 2.84 N·m (+53%) … 脚的供给上限 2.8~3.3 N·m(μ 0.6~0.7)—— v6 正好顶在天花板上, 所以滑移一点没降。… 结论: "减小摆动幅度以降低偏航动量"这条被 v6 证伪 —— 砍 39% 幅度, 需求反升 53%。下一轮不要再走这个方向。”
train/WALK_DIAGNOSIS.md § ② 未生效的机理: 减小摆动幅度反而让偏航需求上升 Push DR helped one lineage and hurt another at the same dose - robustness budget is conserved and gets borrowed, not created
push-dr-conditional-budget-conservationBefore opening a disturbance-DR rung, measure whether the untrained policy already meets the spec; if training it anyway, expect the benefit to be conditional on the lineage's existing DR load, grade the intensity, and audit retained margins - budget spent elsewhere will be borrowed back.
Symptom
The push rung's outcome flipped with the lineage: direct +/-0.6 m/s push failed outright on first attempt (base walking collapsed - kd1.2 scan 0/3 from iter 3300, sim2sim self-falls with pushes OFF - no PASS point existed); staged +/-0.3 then gave the narrow-kd single-working-point lineage real gains (push survival 1/5 -> 4/5) while the SAME dose made the dual-working-point balanced-band lineage WORSE (20-seed survival 18 -> 12/20 plus across-the-board push regression).
Context
The four-ladder verdict ("四梯定案", s2e/s2f at both intensities) named the pattern: "push DR 收益条件性" - the benefit is conditional on how much robustness budget the lineage has already spent. The law candidate: "DR 总预算守恒, 平衡带鲁棒性从抗扰余量借" - total DR budget is conserved; a lineage already covering a wide plant band pays for push tolerance out of its disturbance margin. Both S2 ladders therefore closed at the friction rung, with the decisive numerator: untrained push tolerance already met the 4-6 N*s requirement, so the rung was not needed at all ("⑥ push 不训(收益条件性,免训 ±0.6 已达 标)"). The same accounting later justified the C-before-S2 ordering ("push/μ 两轮已实证 DR 预算有限且会被重分配") and trimmed the second S2 pass to three rungs.
Change
Push removed from the standing ladder; graded intensity retained as the method IF a lineage ever needs push training; "does the untrained policy already meet the disturbance spec" instituted as the first check before opening any disturbance rung.
Outcome
Two rungs (push, ground mu) deleted from the second S2 pass on measured grounds; the ladder's real yield was re-stated honestly as precision, not robustness (speed gate 0 -> 20/20, zero-command drift 0.98 -> 0.06 m, but push 159 -> 125/160).
Mechanism
A fixed-capacity policy allocates representation and margin across the training distribution; adding a disturbance axis to a lineage that already spans a wide plant family forces reallocation - the new tolerance is bought with existing margins. Lineages with narrow plant coverage have free budget, so the identical DR dose lands as gain. Benefit is a property of (dose x lineage state), never of the dose alone.
Applies when
- proposing push/perturbation training on a hardened lineage
- the same DR rung helped one lineage and hurt another
- accounting where a ladder's robustness gains actually came from
“push DR 收益条件性 —— s2e⑥a (单工作点血统 kd 窄带) ±0.3 得抗推 1/5→4/5; s2f⑥ (双工作点平衡带血统) 同档反而 20-seed 存活 18→12/20 且抗推全面倒退。规律候选: DR 总预算守恒, 平衡带鲁棒性从抗扰余量借。两阶梯均以 ⑤ 摩擦级收官 … 抗推 4~6 N·s 免训已达标。”
train/OMNI_V0_SPEC.md § 4. ⑥ push 四梯定案 (2026-08-07) Set torque limits per joint from measured gait peaks - a uniform percentage is the wrong shape, and training must use the deployed numbers
torque-limit-shape-by-measured-peaksMeasure per-joint torque peaks in the actual gait and set each limit as measured-peak x margin capped at rating; then propagate the same numbers into training and add an automated deploy-time consistency check - never derate by a uniform percentage, never let training assume torque deployment will not grant.
Symptom
A uniform 50% torque derating (18/8.5/7) had piled safety margin on the joints that never use it while cutting the busiest joint below half its measured demand.
Context
Per-joint gait peaks were measured (walk_v5 at cmd 0.3/0.6): RS06 (hip_pitch/knee) uses 5.5-5.9 N*m = 15-16% of its 36 N*m rating - cutting it to 12 is a free safety win; RS02's ankle_pitch runs at 16.2 N*m = 95% of its 17 N*m rating - "它是速度的硬件瓶颈", no room to cut; RS00 measured 36-44%, capped at 11. The resulting shape 12/17/11 replaced the uniform percentage. Sweeps across several limit sets (rated / 50% / 14-17-11 / 12-17-11) produced identical speed, lift, and landing force - within this range the limits do not shape the gait; what matters is consistency: "关键是训练和硬件必须是同一个数", because the exporter fills effort_limit from tau_limit, and a policy trained at rated 36/17/14 "会假设有三倍力矩可用" while deployed at 12/17/11 (exactly the v5 cross-generation inconsistency later suspected in its wild kicking).
Change
robot.yaml tau_limit set to the measured-shape 12/17/11, firmware written to match, and train/isaac_values.py regenerated so training sees the same limits; the deploy tool self-checks limits against robot.yaml on every run.
Outcome
Free safety margin captured where demand is low, the real bottleneck joint left at rating, and the train/deploy torque worlds unified with an automated consistency check.
Mechanism
Torque demand is grossly unequal across joints in a gait (15% vs 95% of rating here); a uniform percentage misallocates the safety budget by construction. And since the trainer treats effort_limit as a plant truth, any train/deploy mismatch is an invisible plant gap of exactly the mismatch ratio.
Applies when
- choosing safety torque limits for a legged platform
- training-vs-deployment actuator limit audit
- one joint runs near rating while others idle
“曾用统一 50%(18/8.5/7)是错的形状: 把余量堆在用不到的 RS06 上, 却把 ankle_pitch 砍到需求的 52%。… RS02 在 0.6 m/s 已用到额定 95%, 它是速度的硬件瓶颈 … 实测多组限幅 … 完全一致 —— 限幅在这个范围对步态零影响, 关键是训练和硬件必须是同一个数。… 若训练仍按额定 36/17/14, 学出的策略会假设有三倍力矩可用。”
train/WALK_V6_MINIMAL.md § 3. 训练侧必须同步的一件事 Push-test protocol - positive side first, fragile side spotted, axes aligned in the log, and cross-machine push counts stay qualitative
push-test-chirality-protocolOrder disturbance tests from the robust side to the fragile side with protection scaled to sim-measured asymmetry, align and log frame conventions before testing, and treat cross-domain disturbance counts as qualitative evidence only.
Symptom
Hand-push testing on hardware risked falls on a side sim had already flagged as fragile, and push counts invited apples-to-oranges comparison with sim numbers.
Context
Sim chirality was explicit: descendants were far more fragile in -y (fric-3000@kd1.2: +6 N*s survived 15/20 vs -6 N*s only 3-9/20) while the s1e control was perfectly symmetric (40/40). The protocol therefore: push the positive direction first, keep a spotter for the negative side; before any push, record which real-robot side corresponds to sim's +y in the log ("上机前对一次坐标"); and - citing the chaos lesson ("混沌课文") - real push results are used only as qualitative corroboration, never compared numerically with sim survival counts across machines.
Change
Push testing became a scripted, chirality-aware protocol with frame alignment as a logged precondition and an explicit epistemic limit on cross-domain count comparison.
Outcome
The fragile side was tested with protection informed by sim's quantified asymmetry; logs stayed interpretable because the frame correspondence was recorded before the first push.
Mechanism
Disturbance-response chirality is a real, quantifiable lineage property, so test order should follow measured fragility; and perturbation outcomes are chaotic in the details (divergent trajectories from tiny differences), so counts do not transfer across domains even when qualitative rankings do.
Applies when
- planning push/disturbance tests on hardware
- sim shows directional asymmetry in disturbance survival
- someone proposes comparing real push counts to sim counts
“先正向后负向, 负向留人扶 —— sim 手性明确: 后代在负 y 向显著更脆 (fric-3000 @kd1.2: +6 N·s 15/20 vs −6 N·s 3~9/20), 而 s1e@0.8 两向 40/40 完全对称。上机前对一次坐标 … 跨机不做二值结论 (混沌课文): 真机推力只作定性对照, 不与 sim 计数对比。”
train/REAL_RUN_S2.md § 3. 抗推 (可选, 人手推; 做则按此协议) Model CAN polling skew - joint observations are 6-9 ms stale by read order
can-timing-skew-modelingIf joints are read sequentially over a shared bus, reproduce the per-group observation staleness in sim (or randomize it over the measured range) - synchronous observations are a privileged fiction.
Symptom
Policies trained with synchronous joint observations degrade on hardware where motors are polled sequentially over CAN - hip data is already 6-9 ms old by the time ankle data arrives.
Context
Menlo's core sim2real finding on a leg platform of almost identical mass to Lucen's. CAN is a sequential bus: one poll cycle reads motors in a fixed order, so the observation vector mixes timestamps. Lucen runs 6:6 motors on a dual CAN split, so the problem transfers one-to-one.
Change
Explicitly model CAN timing skew in sim: give the joint groups different observation delays matching physical read order. Menlo went further - running real firmware in the loop with a motor simulator between MuJoCo and firmware injecting 0.4-2 ms uniformly distributed delay.
Outcome
Reported by the reference team as their core sim2real enabler on a same-scale platform; recorded in Lucen's experience log as directly applicable ("这个问题一模一样").
Mechanism
A policy exploits any cross-joint temporal coherence present in training observations; when hardware breaks that coherence per bus position, the learned feedback acts on inconsistent state estimates, injecting phase error exactly at the control bandwidth.
Conflicts
Second-hand episode: outcome numbers are the reference team's report, not a Lucen-run experiment; Lucen adopted the requirement but the corpus has no Lucen A/B of skew-on vs skew-off.
Applies when
- robot polls actuators sequentially over CAN/RS485 or similar shared bus
- sim2real degradation appears as jitter or oscillation not seen in sim
- designing the observation/delay model before a training run
“电机走 CAN 是顺序轮询的,髋部电机的数据到踝部电机上报时已经陈旧了 6-9 ms,他们直接在仿真里显式建模了 CAN 时序偏斜,按读取顺序给三组关节不同的观测延迟。… 注入 0.4–2 ms 的均匀分布延迟。你们是 6:6 双 CAN 分总线,这个问题一模一样”
Experience.md § 执行器 + 时序建模 (line 6) A DR tail the robot never has is pure cost - stage deterministic plant levels instead of one wide uniform
dr-tail-plant-continuationSet every DR range from the measured deployment distribution and cut tails that hardware cannot produce; when an axis changes the controller's character (delay, major gain regimes), prefer staged deterministic levels with gates over one wide uniform.
Symptom
Two consecutive lineages (s1e, s1f) trained under uniform latency DR (0, 0.06 s = 0-3 frames) both converged to drag-glide gaits - buying survival under heavy delay by giving up swing (3.6 mm) - even though the real pipeline never exceeds ~2 frames.
Context
The account: roughly 1/3 of training quality was spent on the >2 frame tail that hardware never presents ("uniform 尾部 ~1/3 训练质量 花在真机不出现的 >2 帧上"). The deeper reading came from the user: uniform 0-3 frames is not merely tail-heavy - it "把性质不同的控制系统 混进同一 PPO batch" (mixes qualitatively different control systems into one PPO batch); a 0-frame and a 3-frame plant demand different controllers, and one policy trained on the mixture serves neither. The S2 v2 ladder therefore redefined latency "从「随机化参数」重新定 义为 actuator/control plant 的一部分": deterministic FIFO levels, staged 1 frame then 2 frames (lo=hi so fractional interpolation degenerates to exact N frames, synonymous with the harness --delay N), each level gated by the fixed acceptance battery - a plant continuation, not a randomization.
Change
Latency DR replaced by staged deterministic levels covering the measured 1-2 tick reality with no tail; each stage a separate continuation rung with the standard gate and rollback.
Outcome
The s2_lag1 rung showed the clean-signal benefit immediately (survival 20/20, heading 6x recovery) with the swing cost booked honestly (21 -> 12 mm, half-pass, ladder paused for adjudication); the drag-glide attractor from uniform tails did not recur.
Mechanism
DR asks one policy to cover a plant family; when part of the family is fictitious, the policy pays real capability for fictitious robustness, and when family members demand structurally different controllers, gradient averaging produces a compromise controller optimal for none. A measured, discrete plant set matches the actual deployment support and keeps each rung's training signal coherent.
Applies when
- policies converge to degenerate gaits that buy worst-case survival
- a DR range extends well past the measured hardware range
- choosing between wide randomization and a staged ladder on an axis
“两轮实证(s1e/s1f)宽尾延迟 DR 逼出拖地滑行 … uniform 0~3 帧不止尾重,而是把性质不同的 控制系统混进同一 PPO batch;1→2 帧确定性分级 = plant continuation,训练信号干净得多—— latency 从「随机化参数」重新定义为 actuator/control plant 的一部分。”
train/OMNI_V0_SPEC.md § 4. v2 阶梯 (2026-08-07 用户定) Write each config's expected hardware signature before the session - and if reality disagrees, change the books, not the conclusion
preregistered-real-expectationsBefore hardware runs, write per-config expected signatures and the disagreement rule (hardware outranks sim; discrepancies get recorded, not reconciled); validate the harness by checking it reproduces at least one known real behavior.
Symptom
Hardware impressions are easily narrated after the fact; without written expectations, any real-robot outcome can be made to "match" the sim story.
Context
The S2 acceptance sheet carried a section titled "sim 侧预注册预期 (事后核对, 不许事后改)" - per-configuration behavioral signatures written before the session: s1e@0.8 the disturbance king (push 159/160, zero chirality, all-mu 20/20) at the cost of speed gates 0/20 and zero-command wander ~0.98 m with -29.5 deg/20 s rotation; fric-3000 "walks accurately but is easier to push over"; fric-2400 neither. Credibility check included: the sim harness had reproduced the already-recorded real behavior (pace in place + right drift + net rotation -30 deg/20 s), which "提高本单全部预期的可信度". The anomaly clause fixed the epistemics in advance: if results systematically disagree with sim, "不改结论改账" - don't massage the conclusion, write the discrepancy into the books, and per the earlier zero-warning lesson, hardware wins.
Change
Every hardware session ships with a pre-registered expectation table (signature per config), a baseline-match credibility check, and a written precedence rule for disagreement.
Outcome
The A/B session became falsifiable: agreement confirms the proxy, disagreement is booked as a proxy-bias finding rather than argued away.
Mechanism
Pre-registration converts qualitative hardware sessions into tests of the sim-to-real mapping itself; a reproduced known behavior calibrates trust in the remaining predictions; and fixing "who wins on disagreement" beforehand prevents authority from drifting to whichever source flatters the plan.
Applies when
- planning any hardware acceptance or A/B session
- the sim harness's credibility in this regime is unestablished
- post-session write-ups tempt narrative fitting
“⚠️ sim 复现了真机已记录的「原地踏步 + 右漂 + 净旋 −30°/20s」—— harness 与真机行为对得上, 提高本单全部预期的可信度。… 结果与 sim 系统性不符 → 不改结论改账: 写进 README 该节, 按 「Isaac 指标三次零预警」的教训, 以真机为准。”
train/REAL_RUN_S2.md § 2. sim 侧预注册预期 (事后核对, 不许事后改) / 4. 异常处置 A plateau in a training curve was a population mix, not a half-learned skill - 60% standing at 0.372 m and 40% sitting at 0.19 m - and a category at hard zero stayed at zero through 3,000 more iterations
zero-partial-credit-is-not-an-iteration-problemBefore buying iterations for a plateau, split the metric by category and check whether it is bimodal; a category at hard zero with no partial credit is missing a capability or a reachable state, and more iterations under an unchanged config will only polish the categories that already work.
Symptom
After R0.1 the training-side base_height sat near 0.29 m and the curve was still climbing at the iteration cap, which read as "train it longer".
Context
Candidate A (user decision) was a child-run from R0.1's last checkpoint with zero config change - the logged env.yaml files differ only in log_dir - for 3,000 more iterations (R0.2). The per-category acceptance split was already available: prone had scored 0/156 with no partial credit.
Change
Continue training unchanged, then read the result by category rather than by the pooled curve.
Outcome
supine 91.5 -> 96.4%, side 82.2 -> 87.9%, get-up 0.96 -> 0.84 s, pose error 0.91 -> 0.54 - all improvements to categories that already stood. Prone stayed 0/153; mid 55.9 -> 41.2% was within noise (n=34). Height by category was binary - standing groups 0.372/0.373 m, seated groups 0.187/0.194 m, nothing between - so the pooled 0.29 was 0.61 x 0.372 + 0.39 x 0.19 = 0.30 (measured 0.307): six in ten standing, four in ten sitting. The rendered prone episode was still kneel-sitting at t = 8 s.
Mechanism
The pooled mean of a binary outcome only moves when the mix moves; PPO kept polishing the subpopulation that already succeeded while the failing one produced no advantage signal to follow.
Conflicts
R0.2 recorded the missing capability as "prone lacks rolling over"; R0.3's end-state confusion matrix retracted that - prone had righted its torso in 159/159 episodes and was failing to stand from the W-sit. The lesson that iterations could not fix it holds; the named cause was wrong.
Applies when
- a training curve plateaus while acceptance shows one category at zero
- deciding between "train longer" and "change something"
- pooled training metrics are read as the typical episode
“**分类别 h 中位把"平台 = 人口混合"钉死了**:数值是**二值**的 —— 站立组 0.372/0.373,坐姿组 0.187/0.194,**中间没有过渡态**。 … **这也是本仓此后读该指标的通用告诫:全体混合的期望会把 双峰分布平均成一个不存在的中间值,必须分类别看。** … **结论:A 不能过门,原因确定为 prone 缺"翻身"这一技能,不是迭代不够。**”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §13 R0.2(recovery_r0_2,child-run 续训):A 走完了 —— 推不动 prone Drop the frozen policy into chosen configurations - a squat 2.7 cm lower than the stuck pose stood 52% of the time, the stuck W-sit 0%, and the interpolation between them showed a wall, not a slope
configuration-probe-wall-not-slopeWhen a policy is stuck, probe the frozen policy from a grid of hand-placed start configurations, including interpolations between the stuck state and a nearby state it escapes from; one read-only experiment separates height, torque, sampling and configuration and tells you whether to prevent entry or train the exit.
Symptom
After R0.3 the policy stood from 62% of starts and never from the W-sit it fell into; height, torque, missing samples and reward were all plausible suspects.
Context
A read-only probe placed the R0.3 policy directly into specified configurations. Squats (hip, knee, ankle) = (-.65,-1.3,-.65) stood 100%, (-1.0,-2.0,-1.0) 89.8%, (-1.2,-2.4,-1.2) at 0.176 m 52.3%; the measured W-sit at 0.203 m 0.0%; the account-(3) hand-over state (146 deg tilt) 34.4%; linear interpolations from the W-sit toward the squat at 25/50/75% stood 0.0/0.0/3.1%. The squat family's quasi-static torque is 16% of the limits, and the W-sit was visited ~9 s per episode in training. FK showed the squat family (-a,-2a,-a) keeps the torso vertical, the feet flat and the COM over the feet all the way from 0.146 m to 0.384 m.
Change
Height, torque and sampling were eliminated in one experiment; the next rungs targeted entering the W-sit (foot placement) instead of escaping it, and seeding the dead point itself was ruled out because it was already visited every episode.
Outcome
Pure configuration: the W-sit (hips externally rotated +/-47 deg, knees folded 110 deg, shins flat, feet beside the body) is a different place from the sagittal squat (feet flat under the COM). The policy's standing skill was bound to a narrow sagittal family, and the wall was confirmed by the interpolation. The foot-placement rungs that followed took prone from 0/159 to 158/159.
Mechanism
A learned skill covers the neighbourhood of the states it succeeded from; a start state outside that neighbourhood fails regardless of height or torque, and an interpolation that stays at zero until close to a working state shows the boundary is sharp.
Applies when
- a policy stalls in a specific posture and several causes are plausible
- deciding between reverse-curriculum seeding and entry-prevention shaping
- a feasibility account says a path exists but the policy does not take it
“**决定性对比:比死点矮 2.7 cm 的蹲姿站立 52.3%,死点 0.0%。** 所以不是高度、 不是力矩(蹲姿族准静态力矩膝 1.96/12、踝 1.24/17,只占 16%)、也不是训练采样 (死点每局被访问 ~9 s)。**是纯位形问题** … 插值实验进一步显示这**不是坡是墙** —— 走到 75% 仍只有 3.1%”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §15 死点位形实验(只读探针,同一个 R0.3 策略放进指定位形) The first real-robot get-up was "very violent, kicking on the floor, dangerous" - a sim-perfect policy with no reason to be slow, unbounded absolute targets, no domain randomization and a rate limiter that filtered nothing; the task was restated as "safe, slow, transferable"
first-real-get-up-violent-stage-one-policyDo not put a get-up policy on hardware until its action is bounded (hard bound or state-anchored targets), smoothed, randomized and tested at the real pipeline's latency, and say explicitly that the task is "safe, slow and transferable" - a simulation-perfect policy optimizes only "gets up".
Symptom
On 2026-08-09 the user ran a V0-lineage recovery policy on the real robot and stopped it: very violent, kicking on the floor, dangerous. The planned next rung (a heavier torque_headroom) was never started.
Context
The spec had pre-registered that R0/R1 products stay in simulation and that the real-robot precondition was the R3 smoothing rungs plus a bridge-slew check plus a hanging protocol; the robustness (DR) rungs had not run. In simulation the policy passed 100% with a get-up of about a second. Which ONNX, which gain profile and whether a torque/joint log existed were left "to be recorded later" and never were.
Change
The V0 ladder was stopped at its best product (R3.1, sim only) and a re-rooting proposal was put to the user. The spec's four-layer account: style (the reward pays for standing early and nothing pays for slowness - HumanUP's "Stage I" get-up, "fast but unsafe ... infeasible for real-world deployment"); impact (full-range absolute targets with no hard bound, raw |a| up to 4.77, action saturation 100%, a single-step change of 0.306 saturating hip_pitch); transfer (zero DR, friction pinned at 1.0, the learned leg bracing); link (the bridge's RL slew equals vel_limit, 0.2-0.66 rad per step, while the real pipeline has 1-2 steps of time-varying latency and acceptance ran at delay 0).
Outcome
The line was re-rooted twice (training-side rate limit, then the beta-anchored action space) and gained a hang protocol before the next real attempt; on 08-11 a beta-anchored policy produced the line's first real get-up.
Mechanism
A task reward that pays for standing early selects the fastest feasible get-up; with absolute full-range targets every large target jump is a torque impulse bounded only by the clip; zero DR and braced-leg solutions do not transfer; and a limiter set at the velocity limit does nothing at 50 Hz.
Conflicts
The four layers are the spec's reconstruction from simulation probes and the literature; the real run's policy file, gain profile and log were never recorded, so no layer was confirmed against hardware data.
Applies when
- a first hardware trial of a high-effort skill is being scheduled
- sim success is high but the policy saturates actions or torques
- pre-registered hardware preconditions are not all met
“用户真机反馈:**非常猛、地上乱踢、危险**,叫停(R3.3 torque_headroom 加档已选型 weight −0.5→−1.5,未启动)。真机细节(哪个 onnx、什么档、有无 τ/q log)**待补记** … 任务从"能起来"变成 **"安全、慢、可迁移"** … **链路层**:桥层 slew RL 档 = vel_limit(10/20/33 rad/s ≈ 每拍 0.2~0.66 rad), 对 recovery 形同虚设;真机 1~2 拍时变延迟,验收默认 delay 0。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §26 真机叫停与换根判决(2026-08-09) When hardware underperforms, audit deployment knobs before prescribing retraining
deploy-knob-attribution-before-retrainingBefore any "retrain it" decision, reproduce the symptom in sim under the exact deployment configuration; if the symptom follows the deployment knob rather than the checkpoint, fix the knob or randomize it in training - never top-up-train the skill.
Symptom
Real-robot feedback after the C4 deployment - "turning is weak" - with two retraining options on the table: top up turn training, or restart from the s1e root.
Context
The sim account showed the policy turned well (75-81% at pw1.0); the robot was deployed at power-scale 0.8. The 3-6 pp difference between C2 and C4 policies at the same power was noise; the 40-50 pp difference between power levels was the entire effect. Both proposed retraining paths would have burned budget on a non-existent training gap, and restarting from s1e would additionally have discarded the sidewalk skill that took four rungs and a coordinate-bug hunt to obtain.
Change
Decision: retrain nothing. (1) Try pw1.0 on hardware first - sim says net gain; (2) only if 1.0 is unacceptable (heat/feel), the correct training fix is power/torque randomization in the S2 plant line (one variable, fixes turn and backward together) - not skill top-up; (3) restart-from-root explicitly ranked worst.
Outcome
The "weakness" was fully explained by the deployment knob; the sim/real signatures matched the earlier power-derating law verbatim ("与 C2 时代 power 衰减主要伤非前进轴 逐字吻合").
Mechanism
The policy's competence is defined under its training plant; deployment knobs (power scale, teleop mapping, command bands) silently define a different plant. Attributing a deploy-plant effect to a training gap produces exactly the wrong fix - more training on the wrong variable.
Applies when
- real robot underperforms a skill that sim says is fine
- proposals on the table include retraining or re-rooting
- deployment uses any override the trainer never saw (power scale, remapped commands, different control rate)
“正确的训练修法不是补训转向,而是训练时加 power/力矩随机化让策略在 0.8 下自己补偿 —— 单变量,属 S2 plant 线,一次同时修好转向与后退;从 s1e 重训是最差选项:丢掉四轮 + 一个指标 bug 才换来的侧走,而 C2 的转向本来就没问题。”
train/C_LADDER_RUN.md § 3p. 三 处置顺序(回答「补训转向 还是 回 s1e 重训」:都不该) Design the next run to complete the 2x2 - either outcome then convicts or acquits a factor cleanly
fill-the-missing-factorial-cellWhen two config factors are jointly suspected, lay out the factorial of existing evidence, spend one run on the missing cell with both interpretations and an early-abort tripwire written in advance - and treat either outcome as a verdict, not a disappointment.
Symptom
Hip joints froze at the action clamp in v7, but the history could not say whether the culprit was the raised action_rate (-0.2) or the halved reference amplitude (scale 0.15): existing versions covered only three corners of the (rate x scale) space - v5 (-0.03, 0.30) healthy, v6 (-0.03, 0.15) healthy, v7 (-0.2, 0.15) frozen.
Context
v9 was designed explicitly as the missing cell (-0.2, 0.30), with the readings pre-registered: v9 not frozen -> the real anti-freeze force was always the reference amplitude and -0.2 may stay; v9 frozen -> -0.2 is convicted beyond appeal (freezes at both amplitudes) and the next version goes straight to a structural fix. "两个结局都是干净的信息" - both endings are clean information.
Change
One training run allocated purely to complete the factorial, with freeze tripwires (joint_pos_ref telemetry <0.1 at iter 1000-1500 -> abort, do not run to 6000) so a conviction costs the minimum compute.
Outcome
v9 froze - the rate weight was convicted at both amplitudes ("−0.2 铁案定罪"), and v10 moved to the structural saturation fix with the weight question closed instead of re-litigated.
Mechanism
Three corners of a 2x2 leave the two factors confounded in the failure corner; the fourth observation makes each factor's marginal effect identifiable. Pre-registering both readings turns the run into a guaranteed-informative experiment regardless of outcome.
Applies when
- two config changes are confounded in a failure
- version history already covers some corners of a factor grid
- deciding what single experiment buys the most attribution
“这恰好补齐一个 2×2 实验矩阵的缺格 … v9 不冻 → 真正的抗冻结主力一直是参考摆幅,−0.2 可以留;v9 仍冻 → −0.2 铁案定罪(两种摆幅下都冻),v10 直接上结构修复 … 两个结局都是干净的信息。”
train/WALK_V9_SPEC.md § 0. 设计原则 (2×2 实验矩阵) Never referee a suspect metric with another metric from the same code - they can share the disease
independent-referee-for-metric-disputesTo adjudicate a disputed measurement, compute the quantity by an independent method from raw state; never accept a sibling column from the same pipeline as the tiebreaker.
Symptom
A triple reversal on one question: sidewalk sign diagnosis (correct) was retracted using a second metric from the same script, then the retraction itself had to be retracted when that second metric turned out to be the buggy one - two opposite-direction errors on the same problem in one day, both written into the execution sheet.
Context
The probe's net-displacement metric suggested the sidewalk reference sign was inverted. Worried about yaw-drift pollution of net displacement, the author checked the same table's body-frame vy_mean column (~0.003 everywhere, 20-50x smaller) and retracted the sign diagnosis. But vy_mean came from mj_objectVelocity, which was silently reporting vertical velocity due to a frame bug - the "referee" was the diseased measurement. Re-measured with a truly independent computation (xmat.T @ qvel, world trajectory), the original diagnosis was confirmed: saw -0.5 gave vy +0.058/-0.130 (76%/106%), consistent with the net-displacement values all along (yaw pollution was real but only 10-21 deg, nowhere near reversal-sized).
Change
Lesson written twice, verbatim, as a hard rule: when questioning a measurement, the referee must be an independent algorithm (different code path, different physical derivation), e.g. rotate qvel by the body matrix directly, or inspect the raw world trajectory.
Outcome
With the independent referee in place the frame bug was confirmed, fixed, and the whole C4 line re-scored - revealing sidewalk had been working (see body-frame-velocity-api-audit).
Mechanism
Metrics sharing a code path (or an upstream API) share failure modes; agreement between them is evidence about the code, not the world. Only a measurement with an independent derivation can break the tie, because its errors are uncorrelated with the suspect's.
Applies when
- two metrics of the same quantity disagree
- about to retract a conclusion based on a second readout
- auditing evaluation code after a surprising result
“我用一个坏指标去质疑一个好指标,并把撤回写进了执行单。教训(写死):质疑一个测量时,不能用同一份代码里的另一个测量当裁判 —— 它们可能同源同病。裁判必须是独立算法(这次的裁判应该一开始就是 xmat.T · qvel[:3],或直接看世界轨迹)。”
train/C_LADDER_RUN.md § 3m. 二 我今天犯了两个方向相反的错 / 3n. 五 元教训 IMU observation age cut 52-68 ms to ~4 ms by moving AHRS onto the MCU - as a single variable
imu-age-move-fusion-downstreamAudit observation age end-to-end and move time-critical fusion as close to the sensor as possible - and when you fix a latency, change only that one variable so the gain is attributable.
Symptom
IMU-derived observations reaching the policy were 52-68 ms old because attitude fusion ran in Python on the loaded host computer - stale attitude is a direct feedback-loop delay the policy was not trained with.
Context
The fix was scoped deliberately narrowly: move the AHRS computation from Python to the STM32 H7 (MC02). CAN topology explicitly unchanged, so the change is a clean single variable.
Change
AHRS fusion relocated Python -> H7. Before/after - IMU age: 52-68 ms -> ~4 ms; CAN timing: unchanged; Python load: high -> ~0.
Outcome
IMU age reduced by an order of magnitude with no confound; host CPU headroom recovered ("把计算单元搬在stm32上, 这样imu有剩余").
Mechanism
Sensor age is pipeline latency, not sensor quality: fusing on the MCU next to the sensor removes host scheduling jitter and interpreter overhead from the critical path. Keeping the bus topology fixed makes the improvement attributable to the relocation alone.
Applies when
- measured sensor-to-policy age far exceeds sensor sample period
- attitude fusion or filtering runs on a loaded host CPU in an interpreted runtime
- planning infrastructure changes during a sim2real campaign
“AHRS 搬到 H7——这个不改 CAN 拓扑,只是把一段计算从 Python 挪到 MC02,单变量:IMU age 52–68 ms → ~4 ms / CAN 时序 不变 / Python 负载 高 → ≈0”
Experience.md § AHRS 搬到 H7 (lines 28-35) Bracket a real-robot A/B with a repeated reference run - battery drain is the confound
battery-bracketed-real-abOrder hardware A/B sessions as A-B-A: repeat the first condition at the end, and void the comparison if the bracket runs disagree - never let battery or venue drift ride on the second condition.
Symptom
In a two-policy teleop A/B on hardware, the second policy is measured on a lower battery voltage than the first - a systematic bias that would be read as a policy difference.
Context
C2 real A/B (checkpoint 700 vs A800, same floor, same day) was scripted as 700 -> A800 -> 700-rerun, with the explicit note that a teleop session drains the pack and the trailing policy "naturally suffers".
Change
Protocol: run the reference policy first AND last; if the two reference runs differ noticeably, declare the whole session battery/floor-polluted and void the A/B ("结论作废重来"). Also log electricity per run.
Outcome
Called out as the round's only systematic confound, closed by one extra command ("这是本轮唯一的系统性混淆源,一条命令就能堵掉").
Mechanism
Battery voltage scales available torque, and torque loss hits behavior asymmetrically (see power-scale-hurts-nonforward-axes), so drain masquerades as policy regression; a head/tail reference pair converts the unobserved drift into a measured control.
Applies when
- comparing two policies or settings on hardware in one session
- any sequential hardware evaluation where the plant drifts (battery, temperature, floor wear)
“为什么要 700 复跑:一次遥控 session 下来电池会掉压,第二枚天然吃亏。头尾各跑一次 700,若两次 700 明显不同,说明这轮 A/B 被电量污染,结论作废重来。这是本轮唯一的系统性混淆源,一条命令就能堵掉。”
train/C_LADDER_RUN.md § 3c. A-3 真机 A/B(同一段地板、同一天、电量记账) A real-robot verdict is (policy x deployment stack) - when the stack changes materially, old verdicts expire
stale-verdicts-under-old-stackDate every hardware verdict with the deployment-stack version it was measured under; after any material stack change, re-test before trusting old condemnations or old praises - with the interpretation of each possible result written down first.
Symptom
walk_v5 stood condemned as "kicks wildly" and walk_v6 as "cannot walk unassisted" - but those verdicts were issued under an earlier deployment stack (--heading did not exist yet, several fixes had just landed); only v7 had ever run under the current unified stack.
Context
New sim evidence sharpened the doubt: a same-harness four-version sweep showed v6 was the HEALTHIEST archive at the real operating point (cmd 0.15: dominant frequency locked at 2.50, steps 35:35 perfectly symmetric, foot distance 203/190 mm best of four, mean tilt 4.2 deg, saturation 15%). A full re-test under the unified stack was scheduled with per-version questions and a pre-filled interpretation table ("判读表(预填假设,回来对号)"): e.g. v6 walks + frequency ~2.5 -> old verdict was the stack's fault, v6 becomes the comparison champion; v6 walks but at ~1.25 -> period-doubling on hardware = confirmed plant gap, actuator fitting promoted to mainline; v5 no longer kicks -> the kicking was an old-stack artifact.
Change
All four versions re-queued on hardware under one stack (same torque limits, slew profile, heading loop, logging), with the version-specific legacy profile pinned; verdicts held provisional until re-issued.
Outcome
The re-test design separated policy properties from stack artifacts before any policy was permanently written off - and turned each outcome into a specific conclusion via the pre-filled table.
Mechanism
A deployed behavior is produced by the policy plus everything between it and the motors (heading loop, slew limits, torque caps, clock); verdicts implicitly condition on that whole stack. Fixing the stack invalidates the conditioning, so old failures may be stack artifacts and old successes may not survive either.
Applies when
- deployment tooling (limits, filters, loops) changed since a policy was last judged
- deciding which historical policy is the rightful baseline
- a sim sweep contradicts an old hardware verdict
“只有 v7 在完整的今日部署栈下上过真机 … v5"左右乱踢"、v6"未能自主"的判决全部来自更早的栈(--heading 尚不存在, 部分修复刚落地)——判决已过期。且 2026-08-02 四代同机仿真横测翻出了新证据:v6 在真机工况(cmd 0.15)下是四代里最健康的仿真档案”
train/REAL_SWEEP_V5_V8.md § 0. 为什么重测 Slowing the gait clock at deployment is out-of-distribution and backfires - lower the commanded speed instead, or train the knob
cycle-time-override-is-oodAny deployment override must correspond to a dimension the policy was trained to handle; to make a parameter field-adjustable, randomize it in training and observe it - otherwise use the levers inside the trained envelope (commands) and leave the knob alone.
Symptom
Real-robot feedback "walks very fast and unstable" suggested slowing the gait; a deploy-side --cycle-time override existed, making "just slow the clock" a one-flag temptation.
Context
A sim sweep of the override on walk_v6 @cmd 0.3 showed monotone degradation away from the trained 0.40 s cycle: at 0.50 s tilt jumped 7.9 -> 13.2 deg and landing force 1.52x -> 2.24x; at 0.80 s (half speed) clearance collapsed to 3 mm - dragging again - with 20 deg tilt. Meanwhile the legitimate lever, lowering the commanded speed with the clock untouched, improved everything monotonically: cmd 0.1 gave 104% tracking, 6.7 deg tilt, minimum slip - the most stable operating point. The file distinguishes the two "slows" explicitly: lower command = smaller steps at the same 2.5 Hz rhythm; a slower rhythm itself requires retraining - randomize cycle_time (e.g. 0.40-0.65 s) during training and expose it as an observation, and only then does --cycle-time become a field-adjustable knob.
Change
Deployment guidance: never ship a cycle-time override the policy was not trained under; respond to "too fast/unstable" with lower commands; schedule clock variability as a training-time (contract-level) change if a field knob is wanted.
Outcome
The sweep quantified the trap before hardware paid for it (dragging and 2.2x landing force at slowed clocks); cmd 0.1 documented as the stable demo point.
Mechanism
The policy is a function fitted around the training distribution; a deploy-side override moves an input (phase rate) to values never seen, so behavior degrades unpredictably - the knob LOOKS like a capability because it exists in the code, but capability lives in the training distribution, not the interface.
Applies when
- a deploy tool exposes overrides (clock, scale, gains) beyond the training distribution
- hardware feels "too fast/aggressive" and a quick knob exists
- deciding between a deploy-side tweak and a retrain
“0.80s | 1.25Hz | 0.165 | 3mm(拖地) | 20.0° … 慢一半直接崩 … 策略按 0.40 训练, 别的周期属分布外。… 降指令速度才是有效杠杆 … cmd 0.1 是最稳的工作点。… 要节奏本身变慢必须重训 —— 训练期把 cycle_time 随机化(如 0.40~0.65s)并作为观测的一维, 部署时 --cycle-time 就成了现场可调的旋钮。”
train/WALK_DIAGNOSIS.md § 2026-08-01 追加: 调慢步态时钟(--cycle-time)在仿真里是反效果 Guessed joint friction was 2.5x low and damping 5x high - measure, then DR around nominal
friction-measured-not-guessedMeasure frictionloss and damping separately (they need different rigs), put the measured value at DR center, and express DR as an additive band around that nominal - a DR range around a guessed value can exclude the real robot entirely.
Symptom
Old MJCF friction values were invented, not measured; when finally measured, every guessed value was wrong by a large factor in some direction.
Context
Joint friction split into Coulomb (frictionloss, tau_c) and viscous (damping b). Measured with the robot hung from a crane (吊机测) while armature was measured no-load; the two measurements are deliberately separated. Old MJCF: frictionloss 0.05, damping 0.1, DR joint_friction range [0, 0.1] "凭空拍的" (made up out of thin air).
Change
Replace guessed values with measured ones - frictionloss: RS06 0.15 / RS02 0.12 / RS00 0.13 N*m (old 0.05, i.e. 2.5x too low); damping: 0.02 N*m*s/rad on all three motor types (old 0.1, i.e. 5x too high). DR reshaped from an absolute made-up range [0, 0.1] to an additive band around measured nominal: joint_friction_add [-0.05, +0.10].
Outcome
"摩擦定稿(与 armature 一起, plant 参数第一次全部来自实测)" - friction frozen as part of the first fully-measured plant; DR now brackets a measured truth instead of spanning an invented interval.
Mechanism
Coulomb friction and viscous damping have opposite behavioral signatures (constant-torque threshold vs velocity-proportional drag); guessing both wrong in opposite directions gives a plant that is simultaneously too easy to start moving and too hard to move fast. DR centered on a wrong nominal makes the policy robust to a family of plants that does not contain the real one.
Applies when
- plant friction/damping values have no measurement provenance
- DR ranges are absolute intervals rather than bands around a nominal
- policy is over- or under-damped on hardware relative to sim
“测关节摩擦。吊机测,而armature应该空机测试。… frictionloss τ_c (N·m) │ 0.15 │ 0.12 │ 0.13 │ 0.05(低 2.5×) … damping b (N·m·s/rad) │ 0.02 │ 0.02 │ 0.02 │ 0.1(高 5×) … DR │ joint_friction_add: [−0.05, +0.10] 叠标称 │ 旧 [0, 0.1] 凭空拍的”
Experience.md § 摩擦定稿表 (lines 12-25) The fallen-state reset was designed, not sampled from SO(3) - fixed category shares with jitter, a low drop that settles physically, equal left/right shares for mirror augmentation, and a numeric check before training
fallen-pose-reset-distributionBuild a fallen-start distribution from named, physically plausible categories with jitter and a settle phase, keep mirrored categories at equal probability, and check the realized shares and penetration numerically before spending a training run on it.
Symptom
A get-up policy can only learn from the fallen states its resets produce; uniformly random orientations produce ground-penetrating and limit-jammed states the robot can never be in.
Context
R0 reset_root_fallen: supine 30%, prone 30%, side_l 15%, side_r 15%, mid (random axis 50-125 deg) 10%, +/-15 deg jitter, full yaw, dropped from 0.28-0.40 m and left to settle under physics, joints uniform inside the soft limits with a 5% margin plus small random velocities. Random SO(3) was rejected (the advisor agreed). side_l and side_r must have equal probability because mirror augmentation turns a left fall into a right fall. The advisor had proposed supine and prone only for R0; the spec included side and mid because the feasibility accounts showed physical solutions for all of them, and wrote "narrow back to supine+prone" down as the first fallback. With no display on the training box the reset was checked numerically instead of by eye.
Change
Category mix as above; realized shares, settle height and penetration measured over 512 envs before the first run. A fallen-state bank (real falls, settled and stored) was pre-registered for R2.
Outcome
Realized shares 29.3/31.6/16.4/17.8% against the config, settle +0.262 m, final penetration 0/512 (a 0.10 m peak at the write instant, ankle links only, pushed out within 80 ms because the 0.28 m drop floor is shorter than a fully extended leg). R0's failure was a reward basin, not a reset artifact. The fallen-state bank stayed unbuilt through V3.1 (checklist item open); R0.3 later re-sliced the prone share into roll_l/roll_r bands, which is what forced the acceptance distribution to be frozen separately.
Mechanism
A category-structured, physically settled start distribution keeps training on states the robot can actually occupy, and equal mirrored shares keep mirror augmentation a pure doubling of data rather than a bias.
Applies when
- designing reset distributions for get-up, recovery or multi-contact skills
- mirror/symmetry augmentation is on and the task has chiral start states
- no viewport is available to inspect resets on the training machine
“角度 jitter ±15°、yaw 全域、0.28~0.40 m 低空放下由物理沉降,关节软限位内 均匀(留 5% 余量)+ 小随机速度。**不用 random SO(3)**(会采出穿地/极限卡死 等现实不可能状态,顾问同判) … side_l/side_r **概率必须相等**(镜像增强的样本同分布前提)”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §3 R0 任务定义 / §9 核查单 Export every CAD part in the whole-machine frame so URDF rotations are zero and inertia is exact
urdf-shared-origin-exportGenerate the model so that correctness is structural: shared-origin STL export, zero rotations, subtraction-only origins, and an explicit 1e-9 g*mm^2 -> kg*m^2 conversion - never hand-rotate inertia tensors.
Symptom
Hand-assembled URDFs accumulate per-link rotation/origin errors and unit-conversion mistakes in inertia tensors - silent plant corruption that no later calibration can cleanly fix.
Context
Documented CAD -> URDF -> USD procedure from a successful Isaac Lab deployment, kept as the recipe if Lucen regenerates its model.
Change
(1) In CAD, align the whole robot to Z-up, X-forward (Isaac Lab convention) and ground the assembly; (2) export each STL with other parts hidden but the machine's shared origin kept, so all parts share one origin, every URDF rotation is 0, and inertia matrices equal CAD values directly; (3) units: Fusion 360 gives g*mm^2, URDF wants kg*m^2 - multiply by 1e-9; (4) link origin = negative of the joint position; link COM = CAD COM minus joint position; joint origin = difference of the two joint positions; (5) after URDF -> USD import, open the USD separately and set it instanceable before saving.
Outcome
A URDF whose rotations are all zero and whose inertia tensors are CAD-exact, eliminating an entire class of hand-transcription plant errors.
Mechanism
Keeping one shared origin turns every frame transform into a pure translation computable by subtraction, and leaves inertia tensors in the frame CAD already computed them in - no rotation of inertia tensors, the most error-prone manual step, is ever needed.
Applies when
- building or regenerating URDF/MJCF from CAD
- inertia or frame bugs suspected in the plant model
- importing URDF into Isaac Lab / USD
“导出 STL 时隐藏其他零件但导出整机——这样所有零件共享同一原点,URDF 里所有 rotation 全是 0,惯量矩阵直接等于 CAD 值 / 单位:Fusion 360 给 g·mm²,URDF 要 kg·m²,乘 1e-9 / link origin = 该关节坐标取负 … URDF → USD 导入后必须单独打开 USD 设成 instanceable 再存”
Experience.md § URDF 制作流程 (lines 87-92) Verify changes in the run's resolved config (and checkpoint md5), never in the source you edited
resolved-config-is-source-of-truthAttribution and single-variable claims must be made on the resolved per-run config (and checkpoint hashes), not on source diffs; verify every intended variable landed before burning compute, and verify every rollback byte-level against the historical resolved config.
Symptom
An intended arm-B config change never reached the training run - the run was grid-identical (117/117 cells) to its C2 predecessor - and the burn was only understood afterwards.
Context
The repo's discipline hardened around the logged resolved config (logs/<run>/params/env.yaml) as the only source of truth: (1) the C2 root-cause analysis was performed against the checkpoint's logged env.yaml, not the code ("以真相源 23-19-25/params/env.yaml 核实"); (2) C4 added a pre-flight: grep the landed env.yaml for the new keys, and compare the first checkpoints of the two arms - identical md5 means the variable did not land, stop immediately; (3) the C4 full rollback was accepted only after starting a 1-iter run and byte-comparing its resolved env.yaml against the historical 700-era file (identical except 4 dormant schema fields, each verified to be at its no-op default).
Change
Standing pre-flight and post-change verification: dump/diff the resolved config that the run actually consumed; use checkpoint hash equality as a cheap "variable landed" detector between arms.
Outcome
Caught the not-landed variable class of failure; made the rollback provably equivalent to the historical training state rather than believed-equivalent.
Mechanism
Between edited source and the running experiment sit layered overrides, env-var switches, and registration logic; only the resolved, serialized config reflects their composition. Diffing at that level tests the actual experiment; diffing source tests intent.
Applies when
- launching an A/B pair or any single-variable rung
- rolling back to a historical training state
- a run behaves as if a change was never applied
“开训前先验落盘 cfg(上一轮臂B 的改动没进 run,与 C2 逐格 117/117 相同):grep -E "base_com|joint_friction|push_robot|track_lin_vel_y_exp" logs/<run>/params/env.yaml 另:两臂第一个 checkpoint 的 md5 若相同 = 变量没进去,立刻停。”
train/C_LADDER_RUN.md § 3d. ⚠️ 开训前先验落盘 cfg / 3l. 回退清单(验证) The advisor's "runtime five-stage state machine + per-stage reference poses + RL residual" appeared in none of the three papers it cited - reading the originals changed the plan and downgraded two widely repeated industry claims
advisor-paraphrase-vs-paperRead the primary source behind any piece of advice before adopting its architecture; record where the paraphrase and the original differ, downgrade claims the originals do not support to speculation, and adopt what the verified sources actually share.
Symptom
After the violent first real run, an advisor proposed re-architecting recovery as a runtime staged state machine with reference poses and an RL residual, citing HoST, HumanUP and StableMimic.
Context
The three papers were read in full on 2026-08-09 and tabulated (deployment form, what the "stages" really are, hard constraints, references). HoST: one end-to-end policy, height-gated rewards in training, action anchored as q + beta*a with a beta curriculum. HumanUP: two training stages with the same observation/action; the vendor's three-stage state machine is the baseline it beats (41.7% vs 78.3%); Stage II tracks an 8x slowed Stage I trajectory (4x too violent, 10x does not converge). StableMimic: a learned soft gate. On 08-10 more sources were checked the same way: the Agility page does not say Digit's self-righting was learned in simulation (only step recovery is stated as RL), so the claim was downgraded to speculation; HoST's support for the 12-DoF armless Mini Pi exists in its code repository, not in the paper text.
Change
Adopted only what the originals share: a hard action bound or anchored action space, strong smoothing including a second-difference term, a slowed hidden reference, heavy DR and real fallen states. The staged runtime state machine was not adopted.
Outcome
The next re-rooting candidates came straight from the verified material, and the beta-anchored action space (HoST, with the Mini Pi configuration as the nearest real-robot precedent) became V2, the lineage that later stood up on hardware.
Mechanism
A paraphrase compresses a paper into the advisor's own architecture; only the original shows what was actually deployed, what was a baseline, and which numbers came with which ablation.
Applies when
- an advisor, agent or summary proposes an architecture with citations
- an industry claim ("X learned it in sim") is about to justify a design
- several papers are cited for one combined recipe
“⇒ **顾问的核心形态"runtime 五阶段状态机 + 每阶段参考姿态 + RL residual"在三篇引文 里均不存在**,其中 HumanUP 还点名 state machine 是局限。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §26 三篇引文精读判决(2026-08-09 全文核对;顾问转述与原文有出入) Three hardware accounts locked the run design point - and the knee's real speed ceiling is tau_limit/kd, not the firmware limit
feasibility-accounts-lock-design-pointBefore opening a dynamic-gait training line, compute the full account set - tau_limit/kd effective speed ceilings, joint ROM under the intended reference geometry, and thermal RMS at the duty cycle - and let the accounts lock the design point; move only to pre-registered in-table alternates, re-running the accounts first.
Symptom
The run line was believed to require a firmware raise of the RS06 speed limit (10 rad/s) as a hard precondition, and the feasibility script's motor-envelope scan had marked 80/100 mm foot-lift cells "physically feasible".
Context
Three added accounts re-decided everything. (1) Damping tax: in MIT mode tau = kp*(q_des-q) - kd*qd, so sustained rotation is capped at tau_limit/kd = 12/1.5 = 8 rad/s - below the firmware's 10; at peak speeds 6.7-7.9 rad/s the damping term alone eats 10.1-11.9 N*m (84-99% of the torque limit). "提固件 limit_spd 越不过这道税 —— 它是 kd 与限扭的比,不是固件旋钮." (2) Joint ROM: the feasibility script had checked motor envelopes but NOT joint range - the ankle-pitch ROM caps 1:2:1 leg-shortening lift at 62 mm (soft) / 77 mm (hard), so the 80/100 mm "feasible" cells were voided; also firmware-independent. (3) Ankle thermal: duty 0.40 puts ankle RMS at 87% of continuous rating (0.35 -> 93%); long-period big-stride cells hit both ankle torque peak and heat. Verdict: firmware raise DEQUEUED (50 mm design point needs knee 6.7-7.3 < the 8 rad/s effective ceiling < firmware 10); vel_limit stays 10 so sim == robot. The three accounts uniquely lock the design point - 50 mm lift / T 0.60 s / duty 0.40 - "三笔账 唯一锁定,不是调参空间", with pre-registered alternates allowed only inside the table and only after re-running the accounts.
Change
Design point frozen from accounts; hardware precondition reversed by arithmetic rather than by test; reference amplitude (0.84 rad = FK inverse of 50 mm) derived, per-joint action scales sized to the required travel (knee 0.9, hip_pitch 0.6, ankle deliberately NOT amplified - hard limit is adjacent).
Outcome
A firmware work item left the critical path; an infeasible region of the design space was closed before any training; the remaining risk (knee tracking lag from the damping tax) was pre-registered with its own criterion and in-table fallback (duty 0.35) - "这不是'奖励没调好', 是 plant 账".
Mechanism
PD actuators in MIT mode pay kd*velocity out of the same torque budget that tracks position, so the effective speed ceiling is a ratio of configuration constants, invisible to firmware settings; and feasibility is the intersection of ALL constraint families (torque envelope, joint ROM, thermal RMS) - a scan that omits one family certifies impossible cells.
Applies when
- planning running/jumping or any high-rate gait on PD actuators
- a firmware or hardware upgrade is assumed as a training precondition
- a feasibility scan covers motor limits but not ROM or heat
“膝的有效速度顶 = τ_limit/kd = 12/1.5 = 8 rad/s,不是固件的 10。… 提固件 limit_spd 越不过这道税 —— 它是 kd 与限扭的比,不是固件旋钮。… 可行性脚本只查了电机包络没查关节 ROM —— 其 80/100mm 的"物理可行"格作废。… 判决:RS06 提固件对 run v0 不是前置,出队”
train/RUN_V0_SPEC.md § 1. 硬件账判决 / 2. 步态设计点 The latency DR range must cover the measured deployment pipeline - 0-20 ms could not even reach the real 1-2 control steps
latency-dr-covers-measured-pipelineMeasure end-to-end action latency in control steps on your own stack (including cross-process queue boundaries), set the DR range to cover it with margin, and never import a delay count without its control frequency.
Symptom
Action latency was randomized over 0-20 ms (0-1 control step at 50 Hz), but the measured deployment path is 1-2 steps: the deploy process writes the target, an independently running BusWorker picks it up on its NEXT cycle, plus CAN round-trip - the training range could not cover the robot's actual latency at all.
Context
Fix: widen action_latency_s to 0-0.06 (0-3 steps). The external reference's "uniform 6 steps" was explicitly NOT copied - that number depends on his unknown control frequency; locally, a sweep at 0/1/2/3 steps showed walk_v5 survives all with insensitive metrics, so 6 steps "在我们这里没有依据" (has no local basis). The range was set from the measured pipeline with margin, not from a foreign constant.
Change
action_latency_s (0, 0.02) -> (0, 0.06), justified by pipeline analysis (writer/worker cycle boundary + bus time) and bounded by the local latency sweep.
Outcome
The DR band now brackets the true deployment latency; the policy trains against the delay it will actually face instead of a fictional sub-step world.
Mechanism
Latency DR only immunizes against delays inside its support; a range below the physical pipeline guarantees an untrained distribution shift at deployment. The correct range comes from tracing the pipeline's worst case (queueing boundaries + transport), and foreign step-counts are meaningless without the control rate they were measured at.
Applies when
- setting or auditing action-delay randomization
- deployment uses a separate bus/worker process from the policy loop
- importing delay-modeling numbers from other projects
“现行 0~20 ms = 0~1 个 50Hz 控制步, 而实测部署链路是 1~2 步(deploy 写 STATE.target 后, 独立跑的 BusWorker 下一轮才取走下发, 再加 CAN 往返)——现在的区间覆盖不到真机的实际延迟。… 不照抄参考来源的"统一 6 步": 那取决于他的控制频率(未知), 而我们扫过 0/1/2/3 步 … 6 步在我们这里没有依据。”
train/WALK_V7_SPEC.md § ⑤ action_latency_s 0~0.02 → 0~0.06 Isaac splits Coulomb friction into static and dynamic columns - wiring only static means zero loss during motion, silently discarding the identified value
sim-api-friction-columnsWhen installing identified actuator parameters, map each measured quantity to the simulator's exact API column for the operative regime (dynamic for moving loss, viscous for damping), verify per joint after landing, and audit how randomization intervals fall on each column's nominal.
Symptom
The hardware-identified Coulomb friction (tau_c) was about to be installed into the trainer through the friction= field alone - which in Isaac 5 populates only STATIC friction, so during motion the joints would lose no torque at all: "只给 static 则运动中不损耗, 辨识的 τ_c 走路时等于没接" (the identified tau_c would effectively not be connected while walking).
Context
The v12 integration wired all three columns deliberately: armature= and friction= from the 2026-08-04 hardware identification, PLUS dynamic_friction= (Isaac 5 splits Coulomb into static/dynamic; the moving-loss column is dynamic) and viscous_friction= (= the measured joint damping 0.02, aligned to MJCF's damping). Each value was re-checked per joint after landing. A DR interaction was audited and booked rather than hidden: randomize_joint_parameters jitters ALL friction columns with ONE interval - the [-0.05, +0.10] band was calibrated against the Coulomb nominal, and landing on the viscous nominal 0.02 it becomes [0, 0.12], "偏宽但保守" (wide but conservative), accepted with the note that pre-viscous behavior was already [0, 0.10] on a base of 0.
Change
Measured actuator parameters installed across all applicable API columns (armature, static, dynamic, viscous), with the DR side effect on shared randomization intervals audited and recorded.
Outcome
The first generation where the identified plant actually acts during motion in the trainer; the silent-column failure mode documented before it cost a training run.
Mechanism
Physics engines decompose "friction" differently (single coefficient vs static/dynamic/viscous columns); a measured parameter is only installed when it reaches the column the solver reads in the regime that matters (motion, not stiction). Randomizers that share one interval across columns rescale the band by each column's nominal - a hidden unit change.
Applies when
- installing identified friction/armature into any trainer
- porting plant parameters between simulators or engine versions
- joint losses in sim do not match bench measurements during motion
“并额外传 dynamic_friction=(Isaac 5 把库仑拆 static/dynamic 两列,只给 static 则运动中不损耗,辨识的 τ_c 走路时等于没接)与 viscous_friction=(= joint_damping 0.02,对齐 MJCF damping)。… randomize_joint_parameters 用同一个 friction 区间抖三列, [-0.05,+0.10] 是按库仑标称标的,落到粘滞标称 0.02 上成了 [0,0.12]”
train/WALK_V12_SPEC.md § 7. 核查单 (Isaac 接 V.ACTUATORS 新字段) Foot dragging is an attractor, not a low amplitude - and joint damping is the mode switch, adjustable at deploy time
swing-bistability-damping-switchWhen a quality metric is bimodal, stop treating it as an amplitude to be trained up: map the modes against initial conditions and plant parameters, find the parameter that switches basins, apply it first as a deployment lever, and only then bake it into the training distribution (as a plant-family shift, never as an execution-mapping change).
Symptom
s2e_pd-1400's swing height "median 12.1 mm" hid a perfect bimodal distribution: 20 seeds split into a drag mode (2.6-4.9 mm) and a step mode (19.3-24.0 mm) with NOT ONE seed in between - the median sat in the empty gap, and "swing debt -11 mm" really meant "50% probability of falling into the drag attractor".
Context
Two designed experiments closed the mechanism. Test A (nominal plant, 40 seeds): step 42% / drag 58% / middle 0 - at nominal gains, initial conditions alone pick the mode, both modes 100% survivable. Test B (fixed init, kp x kd grid): kd is the mode SWITCH - at kd 1.3 all surviving cells step (13-22 mm), at kd 0.7 nearly all drag (2.7-4.3), only at kd 1.0 does init get a vote; kp >= 1.2 is dangerous (5/6 falls). Global verification at kd x1.3 (20-seed, delay 2): survival 20/20 at ZERO cost, step share 42 -> 80%, swing median 12.1 -> 18.4 mm, slip record low 334, thicker tilt margin - costs: vx 85 -> 78%, saturation +5 pp. A Pareto sweep then priced the knob: step share 42/72/75/88/82/90 across kd 1.00-1.30 with a linear vx tax of -2.3 pp per 0.1 kd - the basin gain is fully collected at kd 1.20 ("1.30 是 over-damping 纯多付税"). Mechanism: low damping leaves a landing micro-oscillation / ground-slide channel the policy can exploit to drag; damping plugs the channel.
Change
Deployment lever adopted: kd-scale 1.20 (conservative 1.15) as the legitimate successor to the power-0.8 crutch ("前者削幅度保稳,后者堵 拖地通道换步态,且不牺牲存活"); training-side prescription: move the DR band to nominal-1.2 x (0.9,1.1) = [1.08,1.32], deleting the [0.7,1.0) drag-teaching zone - a contract-level change requiring digest re-baselining, gated on measuring the real robot's actual kd dispersion first.
Outcome
The kd surgery rung (s2e_kd) delivered basin 8 -> 11/20, slip 405 -> 331, vx 81 -> 85% with no out-of-band fragility (below-band check 20/20) - "拐杖烧进分布的正确姿势", explicitly contrasted with the failed s1g amplitude version: this one changes the plant family the policy has seen, that one changed the execution mapping the policy would have to relearn.
Mechanism
The gait's swing behavior is a bistable dynamical system whose basin boundaries are set by plant parameters; a policy trained across a kd band that includes the drag basin has learned to inhabit it. Shifting the deployed (and then trained) damping moves the system into the step basin without touching the policy - a plant-side fix for what looked like a training deficiency.
Applies when
- a gait quality metric splits into distinct modes across seeds
- deciding between more training and a gain/damping change
- converting a deployment crutch into a training-distribution change
“20-seed 里拖地模式 2.6~4.9mm 与迈步模式 19.3~24.0mm 各半,中间一个不落 … kd 是模式开关——kd1.3 下 6/6 存活格全迈步 … kd0.7 下几乎全拖地 … swing 债的解(至少大半)在部署端阻尼档,不在训练端 … 机理:低阻尼下落脚微振荡/贴地滑给了策略顺势拖行的通道,加阻尼堵之。”
train/README.md § swing 双稳态定性 + kd 部署杠杆 (2026-08-07, 用户设计 Test A/B)