Training Coach
Doctrine
A report may cite any of these as doctrine-N.
doctrine-1Contract freeze and fingerprint disciplineThe policy I/O contract (observation layout, scales, history semantics, action pipeline) is frozen and fingerprinted; every exported policy is stamped and verified; contract changes ship as new versioned profiles that leave old artifacts bit-identical, and old policies run forever under their era's pinned profile.
Case. The 215-dim omni contract was frozen with a three-machine digest; the one contract-level extension (lateral feed-forward) went in as a new `omni_ff` profile with the old profile provably untouched, and the contract checker caught two real wiring bugs before any training (`contract-freeze-and-checker`). A silently changed gait-clock default would have fed old policies a 25% slower clock - closed by pinned legacy profiles (`legacy-profile-pinning`). A stale derived USD forked plant mass 2.2% until an automated source-vs-derived instrument gated it (`derived-asset-staleness-check`). A gain profile is part of the closed loop a policy was trained in and belongs in its stamp; the recovery line's anchored authority was left out of its manifest and recorded as the gap not to repeat (`gain-profile-belongs-in-the-stamp`), and a second policy behind a deploy-side switch made the handoff state itself a contract (`recovery-two-policies-and-a-state-machine`, `walk-recovery-fsm-handoff`).
Coach application. On any proposal touching obs/action semantics, defaults, or derived assets: demand the version/profile plan, the fingerprint update, and the checker extension in the same change; flag any old artifact that would run under new defaults.
doctrine-2Attribution by resolved training params - never eval-override knobsCapability differences between lineages are explained only by digging each lineage's *resolved* training configuration and eliminating columns; evaluation-side override knobs (kd-scale, power-scale, cycle-time) act on the plant for *every* policy and may serve as deployment mitigations but never as explanations.
Case. Low-friction robustness across 8 lineages x 3840 cells was traced to kd DR *bandwidth* - every lineage had ground friction pinned to (1.0,1.0), so "trained friction" could not be the axis; the parameter axis and the plant axis were explicitly separated after the first attribution conflated them (`kd-bandwidth-mu-law-attribution`). "Weak turning" on hardware was a power-scale plant effect, not a training gap (`deploy-knob-attribution-before-retraining`); slowing the deploy clock was out-of-distribution, not a feature (`cycle-time-override-is-ood`). The ground truth for what a run trained under is the logged per-run config, not the source tree (`resolved-config-is-source-of-truth`).
Coach application. Whenever asked "why is lineage A better", require the resolved-param table first; kill zero-variance columns; refuse explanations phrased in eval-knob terms; when a knob helps, label it deployment mitigation.
doctrine-3PASS gates become constraints; FAIL gates become objectivesOnce a skill passes its gate, that gate converts into a standing regression constraint (budget <= 2/20 against the parent baseline) for all later training; gates currently failing are the only legitimate objectives of the next rung.
Case. The C ladder ran one frozen 13-cell x 20-seed matrix at every rung with promotion = "new skill PASS and old skills within regression budget"; C1 was stopped and re-rooted precisely because it trained away the root's backward PASS (`fixed-acceptance-matrix-per-rung`, `preregistered-stop-criteria-per-rung`). The C4 product shipped only at 260/260 cells with zero regression.
Coach application. Keep the ledger: every PASS adds a constraint row; propose rungs only against FAIL rows; treat any constraint violation as stop-and-attribute, never "the next rung might win it back".
doctrine-4One variable per ladder rung - counted against what the checkpoint sawA rung changes one variable, where "one" is counted against the checkpoint's actual training state, not against the current config's diff; batching is allowed only when each change owns a disjoint symptom space with a pre-registered ablation order.
Case. Two rungs failed identically because resuming s1e-500 under the evolved config silently added four plant variables the checkpoint had never seen ("单变量纪律不只看「我改了什么」,还要看「checkpoint 见过什么」" - `resume-state-dr-audit`). v8 legally batched four orthogonal fixes with a written ablation order (`orthogonal-batch-with-ablation-order`); v9 spent one run completing a 2x2 factorial so either outcome convicted a factor (`fill-the-missing-factorial-cell`); v10b's three-way ablation wrongfully convicted the clock and had to be retried fairly.
Coach application. Before any resume: diff cfg against the checkpoint's logged training state. Before any batch: require the symptom-ownership map and ablation order in writing.
doctrine-5Pre-register risks, readings, and stop criteria before the ladderBefore a ladder or risky rung, write down the known risks, the interpretation of every plausible outcome, and hit-any-one stop criteria - frozen before training, tightened when priors say results should come fast.
Case. The C ladder opened with three numbered risks including the exact falsification condition for its own root choice; A/B arms carried "预注册读法(事后不改)" tables; a level expected to fail was run anyway for its pre-registered diagnostic value (`preregister-risks-and-fork-readings`). Stop criteria caught C4-redo rungs at +200 instead of full caps (`preregistered-stop-criteria-per-rung`); hardware sessions pre-registered per-config expected signatures and the disagreement rule "不改结论改账" (`preregistered-real-expectations`, `feasibility-accounts-lock-design-point`).
Coach application. Refuse to open a rung without the written risk/reading/ stop block; after results, read conclusions off the pre-registered table and flag any post-hoc reinterpretation.
doctrine-6Plant parameters are measured, never inventedEvery plant number carries measurement provenance: armature = N^2 x rotor inertia from no-load tests, friction split by rig and by API column, torque limits shaped by per-joint gait peaks, latency traced through the real pipeline, masses weighed - and DR bands are additive around the measured nominal, sized to the measured dispersion.
Case. Guessed friction was 2.5x low and guessed damping 5x high (`friction-measured-not-guessed`); armature had been 0 with a 9:1 gearbox (81x reflected inertia, `armature-n2-rotor-inertia`); a uniform torque derating was "the wrong shape" vs measured peaks (`torque-limit-shape-by-measured-peaks`); the delay implementation itself was a wrong plant for a whole lineage (`latency-lerp-reverse-extrapolation`); the run design point was locked by three accounts including the tau_limit/kd speed ceiling (`feasibility-accounts-lock-design-point`); identified friction had to land in the right simulator API columns to act at all (`sim-api-friction-columns`). The recovery and one-leg lines opened with the same kind of accounts before any reward existed - a connected static path and the torque along it for an armless get-up, and the gains single support needs to be holdable at all (`get-up-feasibility-accounts-before-training`, `single-support-gain-authority-probe`).
Coach application. For any plant value in a config review, ask "measured how?"; reject absolute ranges with no nominal; check API column mapping and derived-asset regeneration whenever measured values land.
doctrine-7Sim2sim gate before sim2real - under deployment conditionsEvery checkpoint passes a second, independently built simulator before hardware, and both the gate and the smoke loop run under the measured deployment conditions (real pipeline delay, honest contact parameters, the deployment gain/power profile).
Case. The standing order "先sim2sim 再sim2real" (`sim2sim-gate-before-sim2real`); acceptance flipped to match hardware only under measured condim/torsional friction (`eval-plant-honesty-contact-params`); gates moved permanently to `--delay 2` after the kicking incident (`pipeline-latency-is-plant-not-dr`); and the harness itself must be audited - a frame-convention bug in the cross-sim evaluator invalidated a whole line of verdicts (`body-frame-velocity-api-audit`). The recovery line's second simulator caught a torque penalty paid for by bracing the legs together (`torque-penalty-bought-by-leg-bracing`), and a 1.8x torque disagreement between the two plants stayed binding because its one surviving explanation was never tested (`torque-disagreement-between-simulators-unresolved`).
Coach application. Block any hardware request lacking a second-sim PASS at deployment conditions; when sim2sim and training-side metrics disagree, treat the evaluator as a suspect too.
doctrine-8Observation honesty - the actor's inputs are a hardware contractThe actor observes only signals the real robot produces with realistic noise; privileged truths go to the critic; history windows are estimators and must train under plant variation; rewards on quantities the actor cannot observe buy only average suppression, never closed-loop correction.
Case. Ground-truth velocity/forces went critic-only (`observation-honesty-critic-only`); frame_hist under zero DR memorized the trainer's plant fingerprint - 0/20 transfer (`history-obs-needs-plant-variation`); world-frame yaw rewards could not teach pull-back because heading is unobservable to the actor - correction was routed to the deploy outer loop instead of breaking the contract (`reward-observability-limit`, `deploy-heading-loop-and-align-training`).
Coach application. Audit every actor-obs element for hardware existence; require minimal plant jitter whenever history/recurrence exists; for each reward, ask "can the actor see this error?" and route correction tasks to outer loops.
doctrine-9Reward economics are audited in realized currencyReward design decisions are made on realized per-step magnitudes under the actual policy and command distribution: price the do-nothing optimum before adding a mode, compare achieved values to the computed ignore-floor, calibrate thresholds between measured healthy and sick distributions, and ship every new penalty with a withdrawal clause.
Case. feet_air_time at weight 2.0 realized 0.038 vs tracking 1.2 - drag was rational (`realized-contribution-audit`); ignoring a vy command cost 28-180x less than ignoring vx until a gated tracking term was added (`reward-cost-of-ignoring-audit`, `gate-new-reward-terms-by-command`); achieved-vs-floor separated "never learned" from "priced out" (`ignore-floor-diagnosis`); the foot-distance wall was placed between measured healthy (0.6% tax) and sick (55%) policies (`calibrate-threshold-between-healthy-and-sick`); the landing penalty carried a pre-registered stand-down condition and actually stood down (`calibration-threshold-with-withdrawal-clause`); two clearance terms were inert until zero-points and gate occupancy were checked (`inert-reward-term-audit`). A get-up policy sat because three gated terms paid the seated pose 84% of the return and the one term that could tell sitting from standing was an exp kernel reading 4.6e-5 at the real error (`seated-basin-dead-exp-kernel`); a torque-tail term was weighted by its measured steady value beside a peer term after the estimate proved 12x off (`tail-torque-needs-hinge-on-computed-demand`).
Coach application. Never discuss weights in the abstract: demand the realized-contribution table, the ignore-floor number, and the healthy-pay calibration before any reward edit is approved.
doctrine-10The zero-cost option must be the desired behaviorFor every penalty, name what the zero-cost option is; penalize failure events (slip, saturation excess, contact in flight windows), never the motion or joints that healthy behavior uses; make degenerate strategies fatal via termination where penalties cannot price them out.
Case. Joint-usage penalties for drift taxed a 1.4%-of-momentum channel 2.7/step and collapsed training; the slip penalty costs a non-slipping gait exactly zero (`penalize-the-slip-not-the-joint`). A frozen-at-clamp joint pays zero action-rate forever - only a pre-clip saturation penalty flips the cheat economics (`saturation-cheating-zero-rate-cost`). Ungated phase shaping made standing 42x more expensive than stepping and cooked the hip motors (`moving-gate-42x-stand-tax`); crouch-shuffling lived until a height termination deleted it (`termination-closes-degenerate-basin`). A gated penalty is an exit: the policy parked just outside an uprightness gate, then just under a height gate, to stop paying a stance tax, and only a positive band plus an always-on guard closed both (`penalty-gate-is-an-escape-hatch`); a soft-limit penalty that charged the standing pose itself bought a 4.1 deg lean (`soft-limit-penalty-charges-nominal-pose`); an unpriced foot attitude was spent on edge-standing (`unpriced-foot-attitude-is-a-free-variable`); and the one-leg line listed its cheapest cheats before training and still met one through a zero-gradient band (`enumerate-cheapest-cheats-before-training`, `binary-band-reward-fake-touchdown`).
Coach application. Run the "零代价的选项是什么" audit on every proposed term; convert motion taxes into event-conditional penalties; check the termination set against each known degenerate strategy.
doctrine-11Measurement discipline: independent referees, signs, distributionsA disputed measurement is adjudicated only by an independent algorithm from raw state; directional ability requires sign-antisymmetry under command reversal; bimodal metrics are reported as mode shares (never medians, never 3 seeds); ratios are not comparable when totals change; reward values compare only within one command distribution; single chaotic events never cross machines.
Case. The triple reversal - a good metric was "refuted" by a sibling metric that shared the disease (`independent-referee-for-metric-disputes`, `body-frame-velocity-api-audit`); same-signed +/- responses were bias, not turning (`same-sign-response-is-yaw-bias`); the swing median sat in a bimodal gap (`median-hides-bimodal-distribution`); "v6 is jitterier" died on absolute energies (`ratio-metrics-need-absolute-check`); yaw gain measured 15x wrong in an oscillating frame (`heading-integral-not-body-rate`); a 44% improvement evaporated under same-distribution comparison (`same-distribution-reward-comparison`); drift direction was a limit cycle (`multiseed-sign-test-for-drift`); a cross-machine push cliff was chaos (`single-impulse-recovery-is-chaotic`).
Coach application. Before accepting any surprising number: ask for the independent recomputation, the sign pair, the distribution shape, and the comparison conditions. Retract in writing when a metric falls.
doctrine-12The deployment pipeline is plantIrreducible pipeline properties - action latency, rate limits, power/torque scaling, teleop command mappings - are part of the nominal plant, modeled from day one and reproduced in every gate; deploy-side scalings are crutches that flag unmodeled plant, and they cannot be algebraically folded into training constants.
Case. Right-leg kicking was over-trained-delay x loop gain; power 0.8 was a gain-reduction crutch that retired when the delay was modeled (`pipeline-latency-is-plant-not-dr`); power derating damages non-forward axes first (`power-scale-hurts-nonforward-axes`); training at 0.4 scale as the "twin" of deploying 0.5 x 0.8 collapsed 0/20 (`deploy-scaling-not-training-equivalent`); one shared teleop speed sent an out-of-band lateral command and the robot clipped its own foot (`teleop-command-band-per-axis`); the latency DR range had not even covered the measured pipeline (`latency-dr-covers-measured-pipeline`). A rate limiter added at deployment only clipped a policy that kept commanding (`deploy-rate-limiter-windup`); moved into training and anchored on the last command it became an integrator in the balance loop (`slew-anchor-is-an-integrator`); anchored on the measured angle it bounded torque and kept the bandwidth (`beta-anchored-action-target`). The walking lines' safe setting, power-scale 0.8, cut the ends of the recovery policy's full-range travel and left its spikes alone; a gain inside the trained band did the job (`power-derating-cuts-full-range-contract`).
Coach application. Demand the measured pipeline latency/limits in the plant model and in gate conditions; treat every deploy-side derating as a question ("what is this compensating?"); block per-axis command sources that exceed training bands.
doctrine-13DR budget is finite; its distribution is the measured supportRobustness is a conserved budget: disturbance training on an already-hardened lineage borrows from existing margins; DR ranges span the measured deployment support - no fictitious tails (they buy degenerate gaits), no single constants (they allow thin-margin specialization); harden the plant only after the task distribution is final.
Case. The same push dose helped a narrow lineage and damaged a balanced one - budget conservation (`push-dr-conditional-budget-conservation`); wide latency tails bought drag-glide, constant values shipped 60% thinner tilt margins - the answer is a narrow band on the measured support (`dr-tail-plant-continuation`, `constant-value-dr-overfits-margin`); task-first ordering because hardening a soon-to-change task wastes budget (`task-shaping-before-plant-hardening`); COM randomization used deliberately as a behavior-shaping tool, and rolled back on symptom per its own contract (`com-randomization-forces-leg-spread`, `com-dr-rollback-on-symptom`). DR that is switched on can still be thin: the run policy fell in the frontal plane its gain-and-latency randomization never touched (`thin-dr-judged-by-channel-coverage`), and a friction priority settled under one action contract had to be re-measured under the next (`friction-priority-re-measured-after-plant-change`).
Coach application. Before any DR rung: check the untrained policy against the spec, the lineage's current DR load, and the measured real-world range; after it: audit retained margins, not just the new tolerance.
doctrine-14Gates measure what hardware feels: posture, margins, stripped assistsAcceptance batteries carry posture-class rows (tilt max median, per-joint L/R asymmetry, temperature) beside task rows, graded margin columns beside binary gates, chirality scored per side, at least one condition that removes the environment's free stabilization, and validated predictive scalars promoted into the gate.
Case. Three same-shaped judging errors - survival, displacement, wz-difference - all missed what the operator felt; posture metrics had the predictive power (`task-metrics-vs-posture-metrics`, `stand-gate-posture-not-survival`); binary survival saturated and hid a 60% margin gap (`constant-value-dr-overfits-margin`); v5 passed everything on the ground and failed suspended (`suspension-probe-removes-free-stabilizer`); the hip_roll (l+r) scalar predicted real drift direction and ordering and entered the battery (`hip-roll-sum-predicts-lateral-drift`); averages hide chirality (`chirality-scored-separately`); gait-quality gates are judged at speeds that demand a gait (`low-speed-commands-reward-dragging`). The recovery line added the rest of the kit: where failed episodes end, not only where they started (`end-state-confusion-matrix`); a frozen acceptance distribution with a pinned seed (`frozen-acceptance-distribution-and-pinned-seed`); video of the metric rollout itself (`video-as-acceptance-record`); and the admission that a 10 s episode cannot see a stance that fails after a minute (`episode-length-bounds-what-a-gate-sees`). The one-leg line removed a foot-spacing wall that no gate measured, and the feet met on hardware (`removed-wall-returns-on-hardware`).
Coach application. Review every battery for posture rows, margin columns, per-side scoring, and an assist-stripped condition; when operator feel and gates disagree, suspect the metric class first.
doctrine-15Fork and root selection: recoverability, maturity, frozen rewardsChoose fork roots by which candidate's deficits the coming training can pay back (precision is recoverable; lost plasticity, symmetry, and margins are not); prefer mature checkpoints as roots even when younger ones score better as products; never fine-tune through a reward change - continuation is legal only with the reward frozen and plant/DR widening one rung at a time.
Case. s1e-500 beat higher-precision candidates because its exclusive strengths were unrecoverable (`fork-root-recoverable-shortfall`); the b300 arm proved maturity is capital against adaptation shock (`root-maturity-vs-product-quality`); the B-arm scatter/half-recover/collapse signature falsified reward-change fine-tuning and drew the legal boundary for S2 continuation (`fine-tune-reward-change-falsified`).
Coach application. For root debates, build the exclusive-strengths table and ask "which side can be trained back?"; require dual-arm evidence for maturity claims; classify any proposed continuation as reward-frozen or not before approving.
doctrine-16Curricula: verified engagement, lineage counters, disease-phase gatingAutomatic curricula must prove they engage (a saturated ratchet is constant DR wearing a curriculum's name); every ramp counts lineage-cumulative progress, not per-process steps; penalties aimed at late-stage pathologies ramp in after exploration noise decays; difficulty rises on measured per-stratum success, never on schedule.
Case. The s1f ratchet capped at iter 248 and never engaged (`auto-curriculum-engagement-check`); the saturation ramp re-fired at +600 after every resume and no shipped product ever saw the penalty (`curriculum-counter-lineage-steps`); the same penalty worked once gated to the disease phase and became an untouchable mechanism (`gate-penalties-to-the-disease-phase`); record-high aggregate reward hid a fully-failing delay stratum (`aggregate-metrics-mask-subgroup-failure`); bucket share is not a gradient lever (`bucket-share-is-not-a-gradient-lever`). An assist curriculum keyed to a pooled success share was withdrawn on the strength of the categories that already worked (`curriculum-criterion-conditioned-on-lagging-category`); a pace set by per-step income moved only when that income was time-gated (`per-step-income-drives-speed-time-gate`), and the same gate had to be retired in a lineage without the disease (`time-gate-vs-wide-stance-retire-the-fix`).
Coach application. Ask every curriculum three questions: does it engage (show the internal state)? what does it count (process or lineage)? when is it present (against the pathology's phase)? Check where shipped checkpoints sit relative to every ramp.
doctrine-17Probe before training: feasibility first, hypotheses in tablesAfter two failed training attempts at a skill, stop training: demonstrate the behavior open-loop, enumerate hypotheses in a written table audited against actual configs cheapest-first, race one probe per side of the sim2real boundary for hardware-only pathologies, and use suspended tests to acquit or convict actuators before blaming authority.
Case. "在黑暗里试钥匙" - four sidewalk rungs failed until an open-loop probe separated exploration/waveform/authority in one experiment (`open-loop-probe-before-reward-tuning`); the foot-drag mystery fell to a seven-hypothesis config audit (`hypothesis-table-code-audit`); the period-doubling was resolved by racing a reward-side and a plant-side evidence line - and both paid off, one per sub-case (`period-doubling-evidence-race`); the suspended test acquitted the roll actuator in one measurement (`suspended-test-isolates-actuator-authority`). A read-only configuration probe told a wall from a slope in the recovery line's seated basin (`configuration-probe-wall-not-slope`), and the fix it pointed to - where the feet are - took prone from 0/159 to 158/159 (`prone-dead-end-is-foot-placement`); a knob that did not move its variable was recorded as no test of the idea (`dof-vel-penalty-is-not-a-pacing-knob`).
Coach application. When a skill resists training, prescribe the probe before any further reward edits; require verified target trajectories before imitation terms; keep a falsified-fixes list so closed roads stay closed (`amplitude-cut-falsified-yaw-fix`).
doctrine-18External advice is recomputed locally; values transfer as ratiosEvery external suggestion is classified adopt / already-have / modify / trap by recomputing its claim on the local reward table and probe data; numeric values transfer only as dimensionless ratios (to tracking weight, leg length, sqrt(gL), control rate); citations are verified to exist.
Case. "Start vy very small" would have destroyed sidewalk learning on this reward table - the gradient scales quadratically (`external-advice-audit-against-own-arithmetic`); swing-height targets and weights transferred correctly only through leg-length and tracking-ratio scaling (`transfer-ratios-not-absolutes`); the "6-step delay" was refused for lacking a control rate (`latency-dr-covers-measured-pipeline`); a borrowed reference's structure was FK-verified and its amplitude re-derived from the division of labor (`reference-structure-fk-amplitude-division`); retrieval agents fabricated verbatim arXiv quotes - only source-verifiable material was used; and one dismissed suggestion later proved right for a different mechanism, and was credited (`cycle-average-tracking-for-gait-quantities`). An advisor's staged state machine turned out to exist in none of the three papers it cited, and reading them changed the plan (`advisor-paraphrase-vs-paper`).
Coach application. Intercept every "paper X does Y" with the local recomputation; convert absolutes to ratios before comparison; verify quotes; revisit dismissed advice when new mechanisms appear.
doctrine-19Hardware sessions are scripted experiments, not tuning sessionsReal-robot time executes a pre-registered matrix: risk-ordered (baseline first, fragile last with a spotter), stage-gated (suspended smoke before ground), A/B sessions bracketed by a repeated reference run, operators briefed on measured zero-command and untrained-axis behavior, chirality-aware disturbance protocols, no field tuning - the only legal field changes are scripted, single-variable, and self-reversing.
Case. The S2 acceptance sheet (`risk-ordered-real-deployment`, `battery-bracketed-real-ab`, `know-zero-command-behavior`, `push-test-chirality-protocol`, `no-field-tuning-protocol`); the RAM-only torque experiment with automatic power-cycle rollback (`reversible-single-variable-field-experiments`); and the sim-veto rule - even sim's condemnations get one safeguarded hardware check when they judge the purpose-built configuration (`sim-veto-needs-real-confirmation`). The recovery line's first real run went ahead with its preconditions unmet and was stopped as dangerous (`first-real-get-up-violent-stage-one-policy`); after it: a staged hang, mat and floor protocol (`staged-hang-mat-floor-for-get-up`), a fixed power-cycle pre-flight and two-machine discipline (`power-cycle-preflight`, `two-machine-config-discipline`), a fall guard replaced rather than switched off (`fall-guard-becomes-a-state`), and logs that are part of the run (`hardware-log-is-the-attribution-input`).
Coach application. Turn every hardware request into a runbook with order, gates, brackets, briefing, and anomaly plays; refuse improvised parameter changes on the floor.
doctrine-20Close questions in writing; restart when the debt is structuralAudited questions get frozen verdicts with citable wording and an explicit reopening bar; hardware verdicts are dated by deployment-stack and calibration state and expire when those change; and when successive rungs shuffle symptoms without net progress, freeze the lineage as regression baselines, pay the structural debts, and retrain minimal - carrying laws and instruments, not weights.
Case. The chirality and COM questions were closed with frozen wording and "no reopening without new hard evidence" (`frozen-verdicts-semantic-boundaries`); v5/v6's condemnations expired with the deploy stack (`stale-verdicts-under-old-stack`); a 2-degree calibration fix moved the whole runnable envelope (`zero-offset-calibration-shifts-envelope`); plant upgrades are era boundaries with paired re-baselining (`plant-swap-invariants-vs-shifts`); and the 2026-08-05 reset froze v5-v11, fixed the latency FIFO / manifest / sampling / reward-table debts, and restarted - producing the lineage that reached hardware SOTA (`freeze-lineage-fix-structure-restart`, `minimal-reward-table-with-provenance`). The recovery line's real-robot verdicts ended up in three places that disagree, one of them an undated note in a command file (`write-hardware-verdicts-back`).
Coach application. Maintain the closed-questions ledger and quote it when symptoms recur; stamp verdicts with stack/calibration versions; when a team is three rungs into symptom-shuffling, raise the restart question explicitly with the freeze-fix-restart pattern.
doctrine-21Name the quantity in the space it lives inA goal, reward term or acceptance criterion about the feet, the base or the contact state is computed from the quantity itself - world poses, forces, per-category outcomes - never through a joint-angle, single-signal or pooled stand-in that assumes everything else sits at nominal; and every detector is validated on a behaviour known not to contain the event before it becomes a gate.
Case. The recovery line was caught three times: |ankle roll| as "flat feet" sold stance width and the real robot slid into the splits, a hip-roll criterion was confounded by 50 deg of yaw, and the joint table said 0.271 m where the feet were 0.159 m apart; task-space terms produced the first flat, wide stance (`joint-space-proxy-for-task-space-quantity`). Flight detection lied in both directions across two lines - foot height flagged 40% false flight on a walking gait, contact force alone flagged slip chatter as hops (`contact-detector-single-signal-lies`). A pooled height average described a robot that did not exist - six in ten standing, four in ten sitting (`zero-partial-credit-is-not-an-iteration-problem`) - and the walking line had learned the same lesson on yaw rate (`heading-integral-not-body-rate`).
Coach application. For every reward term and gate row, ask what physical quantity it stands for and whether it is measured directly; flag joint-space or single-signal stand-ins for task-space goals, ask for a detector validated on a negative control, and split pooled metrics by category before reading them.
doctrine-22Continuation needs a live gradient; a release is chosen by a scanContinue a converged policy only on a change that creates a live gradient, on a short budget, with every checkpoint scanned on the transfer axis; choose a release by running the full battery over a band of checkpoints and stop on signals, never by taking the last one; and when edits to the terminal phase cannot move a behaviour, roll back and retrain with the constraint present from the start, keeping the order in which the lineage acquired its mechanisms as explicit curriculum phases.
Case. A continuation with no new gradient drifted MuJoCo transfer from 100/98% to 80/28% while every Isaac gate stayed perfect, and a live-gradient continuation at the same depth kept it (`converged-continuation-is-poison`). One-leg checkpoints 100 iterations apart failed 1 and 38 of 40 cells, and late ones degraded (`checkpoint-choice-is-a-full-gate-scan`). Four in-lineage stance fixes failed because the stance was the end of the get-up path, and from scratch it grew right (`stance-decided-by-get-up-path`); fixes stacked on degraded states were rolled back by the user (`stop-stacking-roll-back-and-audit`); and the lineage's final recipe, trained from scratch in one run, sat at 0% because the order of its curriculum was part of the product (`curriculum-history-is-part-of-the-product`). The omni line's short adaptation budgets and mature roots are the same law seen from the other side (`continuation-budget-not-from-zero`, `root-maturity-vs-product-quality`).
Coach application. Before approving a continuation, ask for the new gradient, the budget and the transfer axis in the scan; before approving a release, ask for the scan; after three rungs without progress on the target, propose rolling back to the last good checkpoint and a from-scratch phase plan instead of a fourth patch.
Experience cards
41 cards matching “stale-verdicts-under-old-stack”.
A real-robot verdict is (policy x deployment stack) - when the stack changes materially, old verdicts expire
stale-verdicts-under-old-stackDate every hardware verdict with the deployment-stack version it was measured under; after any material stack change, re-test before trusting old condemnations or old praises - with the interpretation of each possible result written down first.
Symptom
walk_v5 stood condemned as "kicks wildly" and walk_v6 as "cannot walk unassisted" - but those verdicts were issued under an earlier deployment stack (--heading did not exist yet, several fixes had just landed); only v7 had ever run under the current unified stack.
Context
New sim evidence sharpened the doubt: a same-harness four-version sweep showed v6 was the HEALTHIEST archive at the real operating point (cmd 0.15: dominant frequency locked at 2.50, steps 35:35 perfectly symmetric, foot distance 203/190 mm best of four, mean tilt 4.2 deg, saturation 15%). A full re-test under the unified stack was scheduled with per-version questions and a pre-filled interpretation table ("判读表(预填假设,回来对号)"): e.g. v6 walks + frequency ~2.5 -> old verdict was the stack's fault, v6 becomes the comparison champion; v6 walks but at ~1.25 -> period-doubling on hardware = confirmed plant gap, actuator fitting promoted to mainline; v5 no longer kicks -> the kicking was an old-stack artifact.
Change
All four versions re-queued on hardware under one stack (same torque limits, slew profile, heading loop, logging), with the version-specific legacy profile pinned; verdicts held provisional until re-issued.
Outcome
The re-test design separated policy properties from stack artifacts before any policy was permanently written off - and turned each outcome into a specific conclusion via the pre-filled table.
Mechanism
A deployed behavior is produced by the policy plus everything between it and the motors (heading loop, slew limits, torque caps, clock); verdicts implicitly condition on that whole stack. Fixing the stack invalidates the conditioning, so old failures may be stack artifacts and old successes may not survive either.
Applies when
- deployment tooling (limits, filters, loops) changed since a policy was last judged
- deciding which historical policy is the rightful baseline
- a sim sweep contradicts an old hardware verdict
“只有 v7 在完整的今日部署栈下上过真机 … v5"左右乱踢"、v6"未能自主"的判决全部来自更早的栈(--heading 尚不存在, 部分修复刚落地)——判决已过期。且 2026-08-02 四代同机仿真横测翻出了新证据:v6 在真机工况(cmd 0.15)下是四代里最健康的仿真档案”
train/REAL_SWEEP_V5_V8.md § 0. 为什么重测 After installing the measured plant, re-run all generations paired on old and new plant - identity metrics carry verdicts, physics metrics re-baseline
plant-swap-invariants-vs-shiftsTreat every plant upgrade as an era boundary: re-run the retained policy set paired (same seeds/flags) on both plants, carry forward only verdicts whose metrics proved plant-invariant, re-baseline the rest - and mine the systematic shifts as measurements of the old plant's biases.
Symptom
With the plant finally fully measured (weighed masses 9.792 kg, bench-identified armature, in-situ friction), no historical sim number was comparable to new runs - "历史 sim 数字跨纪元不可比" - and it was unknown which historical verdicts still held.
Context
The era-2c cross-test ran all seven walk generations on the complete plant under one harness (14/14 survived), then re-ran the same 14 configurations on the OLD plant retrieved from git, same flags and seeds, with a self-check (one historical record reproduced digit-for-digit). The split was clean. Policy-identity metrics moved essentially zero across the plant swap - dominant frequency (v7's period-doubling 1.20 -> 1.20), knee amplitude (9.9 -> 10.0), foot distance (+/-2 mm), saturation (100 -> 100, 0 -> 0) - so all seven cross-generation verdicts (freeze signature, saturation-line closure, knee-collapse location, slip-penalty accounting, N2 lineage, v6's balance, v11's triad) were re-confirmed on the honest plant. Plant-physics metrics shifted systematically with ordering preserved: slip down 10-25% (measured friction makes ground-twisting costlier), landing vertical velocity down 15-50% ("旧 plant 高估落地 凶度"第二次独立证实), landing force mixed (mass up 2.2% vs friction braking the swing - two effects fighting). Exactly ONE behavior-level change: v8's low-speed period-doubling vanished (1.30 -> 2.50, lift normalizing) - confirming it had been machine-dependent bifurcation-edge behavior that armature+friction push off the knife edge, while v7's period-doubling stood untouched: saturation-freeze-driven, a policy property, not a numerical accident.
Change
Era re-baselining protocol: after any plant upgrade, one paired same-seed sweep of all retained generations on old and new plant; verdicts keyed to identity metrics carry over, thresholds re-read against the new-plant table, and the differences themselves become plant-physics findings.
Outcome
Seven verdicts survived with evidence rather than assumption; two causes of the period-doubling family were separated with plant-side proof; and the sim's landing-violence overestimate was independently confirmed a second time.
Mechanism
A policy's structural properties (frequencies, amplitudes, frozen joints) are functions of its weights and survive plant changes; contact-mediated quantities are joint properties of policy and plant and shift when the plant becomes honest. Pairing seeds across plants isolates the plant's contribution exactly, so the sweep both validates history and measures what the old plant had been lying about.
Applies when
- installing measured masses/armature/friction into the sim
- historical thresholds are cited across a plant change
- a hardware-only behavior might be bifurcation-edge sensitivity
“策略身份指标逐位不动:主频(v7 1.20→1.20)、膝摆 … 这些是策略属性,plant 换代携带无损,历史定论因此全部成立。… 唯一行为级变化:v8@0.15 的倍周期消失(主频 1.30→2.50…)——印证当时"分岔边缘、机器相关"的判定:armature+摩擦把 v8 推离刀锋;v7 的倍周期纹丝不动(1.20→1.20),它是饱和冻结驱动的深层属性,不是数值巧合。”
train/README.md § 纪元 2c 全代同机横测 (2026-08-04): 完全体 plant 上历史结论全部存活 A 2-degree joint-zero calibration fix moved the whole runnable envelope - re-test old "cannot run" verdicts after recalibration
zero-offset-calibration-shifts-envelopeDate every hardware verdict with the calibration state; after any zero/mount recalibration, re-test previously condemned policy-power combinations and previously "unexplainable" posture offsets before attributing either to training or model.
Symptom
s1d was on record as "only runs at power 0.7" (kicked wildly at 0.8); after a calibration pass, the same policy ran 12 s at 0.8 with no kicking at all.
Context
The calibration had fixed a 2.08 deg zero offset on r_hip_roll - exactly the constant error source on the dominant joint of the kicking oscillation loop ("恰是乱踢振荡环主导关节的常值误差源"). The three-generation post-calibration hardware sweep also closed a second case: the robot's mysterious "backward lean" disappeared after calibration, and the sim-real posture difference collapsed from opposite-sign 5+ deg to same-sign ~2 deg ("后仰案实质了结") - the lean had been a sensing/zero artifact, not a mass-model error. Booked consequence: if the s1d recovery re-verifies, "真机可跑档整体 上移" - every policy's runnable power envelope shifts up, and downstream lineages' hardware expectations get revised.
Change
Joint-zero and mount calibration promoted from setup chore to a variable that dates hardware verdicts: verdicts about which power/scale levels a policy can run are conditioned on the calibration state they were measured under.
Outcome
One policy rehabilitated at a higher power level; one standing sim-real posture discrepancy closed without touching model or training; a pending re-verification booked rather than asserted.
Mechanism
A constant joint-zero error acts as a persistent disturbance injected at the feedback loop's most-loaded joint; near an oscillation threshold, removing a 2-degree bias is the difference between a stable and an unstable loop. Since the error is additive and machine-side, it shifts every policy's stability envelope simultaneously - which is why verdicts must carry their calibration date.
Conflicts
The s1d rehabilitation awaited one confirming re-run at the time of writing ("待复核一跑坐实") - the offset-as-cause reading is the head suspect, not a closed verdict.
Applies when
- a policy oscillates at a power level others tolerate
- sim and real disagree on a constant posture offset
- deciding whether to re-test old hardware verdicts after maintenance/calibration
“发现①:s1d@0.8 能跑了(旧账「只有 0.7 能跑」)——12s 无乱踢。头号嫌疑 = 标定修正:r_hip_roll offset 修 2.08°,恰是乱踢振荡环主导关节的常值误差源。… 发现②:「后仰」标定后消失 … sim-real 姿态差从反号 5°+ 收敛到同号 2°,后仰案实质了结。”
train/README.md § 真机 @0.8 三代横评(2026-08-07 标定后) When a contract default changes, old policies must run under a pinned legacy profile - a silent clock swap is out-of-distribution on hardware
legacy-profile-pinningTreat every trained policy as bound to the contract values of its training era: version the deployment profiles, pin old policies to their era's profile in every command, and never let a changed default silently apply to an old artifact.
Symptom
The walk profile's gait clock moved from 0.40 s to 0.50 s for new training, but versions v5-v9 were all trained at 0.40 s - running them under the updated default would silently feed a 25% slower phase clock to policies that never saw one.
Context
The re-test runbook hard-codes --policy-profile legacy_walk_040 into every command for the old versions, with the warning not to omit the flag: the mismatch is invisible (no error, no crash) but puts the policy out of distribution on hardware, where the same file had already documented that off-clock operation collapses gait quality.
Change
Deployment profiles versioned per training era; historical policies permanently associated with their era's profile; runbooks write the profile flag explicitly rather than relying on defaults.
Outcome
Old policies stayed runnable and comparable after the contract moved on; the silent-mismatch failure mode was closed by convention.
Mechanism
Changing a shared default rebinds every old artifact to a contract it was not trained under; unlike a schema break, a value change produces no error - only degraded, unexplainable behavior. Version-pinned profiles make the binding explicit and permanent.
Applies when
- changing any default in the deployment contract (clock, scales, gains) while old policies remain in use
- writing runbooks that mix policy generations
- a re-tested old policy behaves worse than its era's records
“2026-08-02 起 walk profile 的时钟改为 0.50(WALK_V10_SPEC §3)。v5~v9 全是 0.40 训的,本文件所有命令已改带 --policy-profile legacy_walk_040 ——不要省掉这个 flag,否则是拿慢 25% 的相位时钟静默喂旧策略(分布外,真机危险)。”
train/REAL_SWEEP_V5_V8.md § 1. 预检 ⚠️ 时钟改为 0.50 The recovery line's real-robot verdicts live in three places that disagree - the spec's "fairly stable, first real stand-up" for v2_6, an undated runbook note that only v3_1p1c works, and a first run whose details were never recorded
write-hardware-verdicts-backA hardware verdict is a dated entry in the authoritative ledger - policy file and stamp, gain profile, floor, battery, tries, log file, what was seen - written back the same day; a note in a command file is a pointer, not a verdict, and a newer verdict that contradicts an older one must say so.
Symptom
Asked "which recovery policy works on the real robot", the sources give different answers, and none of them carries the conditions of the test.
Context
08-09: the first real run was stopped as violent and dangerous; which ONNX, which gain profile and whether a log existed were marked "to be recorded" and never were. 08-11: v2_6 was "fairly stable", the line's first real get-up, with splits after standing; v2_5b's result and both CSVs were "to be reported". 08-14: v3_1p1c was stamped and pushed, with "the real first test still needs the user present"; the spec records no hardware result for it. The operator runbook (undated) puts above the v2_6 and v2_5b floor commands the note that none of the recovery policies below work, only recovery_v3_1p1c - a verdict never written back into the spec, with no date, floor, battery, number of tries or log attached.
Change
None recorded in the sources; this card records the gap.
Outcome
The line's authoritative record ends with v3_1p1c as the product awaiting its first real test, while the operator's note implies it is the only one that works and that v2_6 (recorded as a success) does not.
Mechanism
Verdicts given at the robot travel by word of mouth and command-file comments; without a record carrying the conditions, a later reader cannot tell a changed verdict from a changed floor, battery or stack.
Conflicts
§43 (2026-08-11) records v2_6 as the first successful real get-up ("fairly stable"); the undated runbook says every recovery policy except recovery_v3_1p1c does not work; §49 (2026-08-14) says v3_1p1c's first real test was still pending. The runbook's claim has no date and was never written back to the spec, so it cannot be ordered against §43.
Applies when
- choosing which policy to deploy from an operator's notes
- a hardware session ends without a written result
- two documents disagree about what worked on the robot
“下面的recovery都不行 只有recovery_v3_1p1c.onnx”
RL系统/FOLLOW THIS copy 2.md § #### Recovery Policy (operator runbook, undated) The trainer read a stale USD after the URDF mass update - regenerate derived assets and gate on an automated equality instrument
derived-asset-staleness-checkFor every derived plant artifact (USD from URDF, generated value files), pair the generation step with an automated source-vs-derived equality instrument, prove the instrument can fail, gate training on its PASS, and re-run physical audits after every regeneration.
Symptom
Measured link masses had been committed to URDF/MJCF (total 9.58 -> 9.792 kg, weighed values), but Isaac reads the derived USD asset - which still carried the old masses: a silent 2.2% mass fork between the training plant and the evaluation plant.
Context
The v12 checklist made USD regeneration a hard precondition ("硬性 前置") and, crucially, backed it with an instrument: check_usd_mass.py compares USD vs URDF per-link mass AND inertia trace, validated by showing it FAILs the stale asset naming 9 offending links, then PASSes after re-conversion (13/13 links consistent, total 9.7920). The self-collision filter audit was re-run after the regeneration (three poses, 0.00 N) because a regenerated asset invalidates physical audits done on the old one. This milestone was also where the three plants first aligned: "三边 plant 首次对齐(armature+摩擦+ 实称质量)就在这一代".
Change
convert_urdf re-run on the training machine, regenerated asset committed, check_usd_mass.py PASS required as an acceptance gate for the generation; dependent audits repeated post-regeneration.
Outcome
The 2.2% plant fork was closed before it could distort a generation's acceptance numbers; the staleness class of bug now has a permanent detector instead of a memory.
Mechanism
Source-of-truth edits do not propagate to derived binary assets by themselves; any consumer reading the derivative silently trains or evaluates on the old plant. An automated equality check between source and derivative - proven able to fail - turns an invisible staleness into a red gate, and regeneration invalidates every audit performed on the old artifact.
Applies when
- editing masses/inertia/geometry in URDF or MJCF sources
- a trainer or evaluator consumes converted/derived assets
- plant numbers differ between simulators for no visible reason
“25ba997 把连杆质量更新为实称值(总重 9.58→9.792 kg,URDF/MJCF 已改),但 Isaac 读的是 train/assets/laika_v2.usd —— 仍是旧质量。… 否则 Isaac(9.58)与 MuJoCo(9.79)质量分叉 2.2%,v12 验收数字失真。验收门:python tools/check_usd_mass.py 必须 PASS … 对旧资产实测 FAIL/9 连杆点名,仪器已验证”
train/WALK_V12_SPEC.md § 7. 核查单 (⚠️ 先重转 USD) One fixed acceptance matrix for every rung - new skill must PASS while every old skill stays within a regression budget
fixed-acceptance-matrix-per-rungFreeze one acceptance matrix for the whole ladder; every promotion requires the new skill's PASS plus bounded regression on every prior skill, measured against the parent's baseline under the current (bug- fixed) metric code - and include command transitions, not just steady states.
Symptom
Sequential skill training silently trades old skills for new ones (C1 trained away the root's backward ability); without a constant measurement frame, each rung's numbers are incomparable and regressions hide.
Context
The C ladder ran the same 13-cell command matrix at 20 seeds per cell at every rung (stand; vx +0.15/+0.30; vx -0.10/-0.20; vy +/-0.10; wz +/-0.20; two vx&wz combos; two vx&vy combos), with promotion requiring "新技能 PASS 且旧技能不明显退化" - old-skill regression budget <=2/20 against the parent's recorded 20-seed baseline. For the transition-rich final rung, a command-switch block was added (forward->stop, stop->backward, forward->turn, left->right, turn->forward; survival + re-track within 2 s) because "每个 steady command 都会做 ≠ 命令切换不会摔" - steady-state success does not imply switch safety, and the joystick does switches. The C4 product's gate ran 260 cells (13 x 20) all 20/20.
Change
Battery frozen once, reused verbatim per rung; baselines re-measured per parent (and re-measured again after the metric-frame fix, since old baselines were taken with the buggy coordinate reading - "旧基线是坏坐标系的, 不可引用").
Outcome
Regressions were caught at the rung that caused them (C1's backward loss, C2's vx+0.30 decay), and cross-rung comparisons stayed valid for the ladder's whole life.
Mechanism
A constant matrix makes every rung's output a point in the same metric space, so "did we lose anything" is a table diff, not a judgment call; the per-skill regression budget converts previously earned PASSes into standing constraints on all future training.
Applies when
- designing gates for sequential skill addition
- promoting a checkpoint to be the next rung's root
- after any evaluation-code fix (old baselines must be re-measured)
“新技能 PASS 且旧技能不明显退化才晋级。… C5 追加:命令切换验收(steady ≠ transition) forward→stop、stop→backward、forward→turn、left→right、turn→forward,各 20 seed,判存活 + 切换后 2 s 内是否重新跟上。”
train/C_LADDER_RUN.md § 5. 固定验收矩阵(每级跑同一张,每项 20 seed) Model CAN polling skew - joint observations are 6-9 ms stale by read order
can-timing-skew-modelingIf joints are read sequentially over a shared bus, reproduce the per-group observation staleness in sim (or randomize it over the measured range) - synchronous observations are a privileged fiction.
Symptom
Policies trained with synchronous joint observations degrade on hardware where motors are polled sequentially over CAN - hip data is already 6-9 ms old by the time ankle data arrives.
Context
Menlo's core sim2real finding on a leg platform of almost identical mass to Lucen's. CAN is a sequential bus: one poll cycle reads motors in a fixed order, so the observation vector mixes timestamps. Lucen runs 6:6 motors on a dual CAN split, so the problem transfers one-to-one.
Change
Explicitly model CAN timing skew in sim: give the joint groups different observation delays matching physical read order. Menlo went further - running real firmware in the loop with a motor simulator between MuJoCo and firmware injecting 0.4-2 ms uniformly distributed delay.
Outcome
Reported by the reference team as their core sim2real enabler on a same-scale platform; recorded in Lucen's experience log as directly applicable ("这个问题一模一样").
Mechanism
A policy exploits any cross-joint temporal coherence present in training observations; when hardware breaks that coherence per bus position, the learned feedback acts on inconsistent state estimates, injecting phase error exactly at the control bandwidth.
Conflicts
Second-hand episode: outcome numbers are the reference team's report, not a Lucen-run experiment; Lucen adopted the requirement but the corpus has no Lucen A/B of skew-on vs skew-off.
Applies when
- robot polls actuators sequentially over CAN/RS485 or similar shared bus
- sim2real degradation appears as jitter or oscillation not seen in sim
- designing the observation/delay model before a training run
“电机走 CAN 是顺序轮询的,髋部电机的数据到踝部电机上报时已经陈旧了 6-9 ms,他们直接在仿真里显式建模了 CAN 时序偏斜,按读取顺序给三组关节不同的观测延迟。… 注入 0.4–2 ms 的均匀分布延迟。你们是 6:6 双 CAN 分总线,这个问题一模一样”
Experience.md § 执行器 + 时序建模 (line 6) IMU observation age cut 52-68 ms to ~4 ms by moving AHRS onto the MCU - as a single variable
imu-age-move-fusion-downstreamAudit observation age end-to-end and move time-critical fusion as close to the sensor as possible - and when you fix a latency, change only that one variable so the gain is attributable.
Symptom
IMU-derived observations reaching the policy were 52-68 ms old because attitude fusion ran in Python on the loaded host computer - stale attitude is a direct feedback-loop delay the policy was not trained with.
Context
The fix was scoped deliberately narrowly: move the AHRS computation from Python to the STM32 H7 (MC02). CAN topology explicitly unchanged, so the change is a clean single variable.
Change
AHRS fusion relocated Python -> H7. Before/after - IMU age: 52-68 ms -> ~4 ms; CAN timing: unchanged; Python load: high -> ~0.
Outcome
IMU age reduced by an order of magnitude with no confound; host CPU headroom recovered ("把计算单元搬在stm32上, 这样imu有剩余").
Mechanism
Sensor age is pipeline latency, not sensor quality: fusing on the MCU next to the sensor removes host scheduling jitter and interpreter overhead from the critical path. Keeping the bus topology fixed makes the improvement attributable to the relocation alone.
Applies when
- measured sensor-to-policy age far exceeds sensor sample period
- attitude fusion or filtering runs on a loaded host CPU in an interpreted runtime
- planning infrastructure changes during a sim2real campaign
“AHRS 搬到 H7——这个不改 CAN 拓扑,只是把一段计算从 Python 挪到 MC02,单变量:IMU age 52–68 ms → ~4 ms / CAN 时序 不变 / Python 负载 高 → ≈0”
Experience.md § AHRS 搬到 H7 (lines 28-35) Gate a new reward term by its command so all old modes score pointwise identical
gate-new-reward-terms-by-commandWhen a reward term must be added mid-lineage, gate it on the condition that defines the new task so every pre-existing situation scores exactly as before - and still watch for value-rescale pathologies inside the new mode.
Symptom
Adding a lateral tracking reward (track_lin_vel_y_exp) ungated would have paid 0-2.0 per step even in modes with cmd_vy = 0 (healthy gait sway of vy ~0.1 already earns 1.28), shifting the whole reward table by a large bias and rescaling the value function - no longer "just adding one mode".
Context
C4 was the C ladder's only true reward surgery. Single-variable discipline required that the change be invisible to every existing mode. The chosen construction: gate_by_cmd=True - the term pays only when |cmd_vy| > 0.02, so for all modes with cmd_vy == 0 the term is pointwise zero, i.e. the reward is pointwise identical to before the change. The same trick appeared earlier in C1: replacing the vy L2 tax with a command-error version that is "对 cmd_vy≡0 逐点同值" (pointwise equal when cmd_vy is 0), explicitly classified as not-a-reward-change.
Change
track_lin_vel_y_exp added with gate_by_cmd=True (weight +2.0, std 0.15); the residual acknowledged honestly - inside the side bucket the values DO change, so the rung still watched the known reward-reshuffle pathology signature (s1c B-arm: scatter -> half-recover -> collapse) as a stop criterion.
Outcome
Old modes provably unaffected (pointwise-equal argument); attribution for any change in old-skill metrics stayed clean through the C4 redo series.
Mechanism
PPO's critic normalizes to the reward scale it sees; an ungated additive term shifts returns in every state and re-scales advantages globally, entangling the new skill with all old ones. Command-gating confines the new term's support to the new mode's state distribution, making "pointwise identical elsewhere" a provable property rather than a hope.
Applies when
- adding a tracking/shaping term for a new command or skill to a lineage that must not regress
- reward change proposed while other skills are still being gated
- reviewing whether a config diff counts as a reward change
“只在 |cmd_vy| > 0.02 时付。不门控的话它对 cmd_vy≡0 的老模式也给 0~2.0 分(健康摇摆 vy≈0.1 → 1.28),等于给整张奖励表加一个大偏置、值函数尺度全变 … 门控后老模式逐点得 0 = 与加项前逐点同值,单变量纪律成立。… 但 side 桶内的值确实变了 —— 这仍是奖励表改版,开级盯 s1c B 臂签名”
train/C_LADDER_RUN.md § 3d. gate_by_cmd=True(重要) Removing a hand trim re-exposed the plant offset it had been silently compensating - and a slope scan told bias from sensitivity
hand-trims-hide-plant-offsetsTreat hand-tuned trims as undocumented plant measurements: before deleting one, find what it compensates and re-house that knowledge in the model or the reward budget; diagnose posture errors with a sensitivity sweep to distinguish constant bias from gain problems.
Symptom
After switching from the old hand-trimmed default to the clean geometric zero, the retrained stand policy's only regression was torso lean: 1.8 deg -> 4.1 deg backward.
Context
The old default's ankle-pitch trim (-0.0489/+0.0628) had been pre-compensating a fore-aft COM mismatch; removing the trim removed the hidden compensation, and the posture reward alone was too weak to win it back. A COM sensitivity scan settled what kind of problem this was: sweeping base COM offset -50 to +50 mm gave nearly identical slopes for old and new policies (~0.026 deg/mm) - "不是质心敏感度问题, 是恒定偏置" (not a sensitivity problem, a constant bias). Fix landed in stand_v1b: posture corrected to +0.24 deg while keeping symmetry (<=0.1 deg) and low effort (0.259), disturbance rejection better than both predecessors. Model credibility was checked the honest way: v0's sim prediction at the real COM position (-22 mm) was -2.31 deg lean vs real measured 2.2-3.1 deg - "预测精准命中" - which is what licensed trusting v1b's -0.52 deg prediction. (Side flag from the same file: a sign convention had been documented wrongly in early comments - gravity_base[0] > 0 is forward lean.)
Change
Trims retired in favor of explicit modeling: symmetric geometric default plus a posture-reward budget sized to carry the real COM offset; the offset itself known (real COM ~22 mm behind model).
Outcome
stand_v1b passed acceptance as the standing lineage's final version; the walk-line requirement "加大躯干姿态惩罚权重" was upgraded from suggestion to mandatory, since walking amplifies what standing tolerates (real walk_v1 hit 26 deg lean vs sim 7.4).
Mechanism
Hand trims are plant knowledge stored in the wrong place - invisible, asymmetric, and stale after recalibration; removing them re-exposes the raw plant error. A sensitivity sweep separates the two possible diagnoses (slope change = control problem; parallel offset = constant plant bias), each with a different fix.
Applies when
- cleaning up hand-tuned offsets/trims in defaults or calibration
- a posture bias appears after a default or calibration change
- deciding whether a lean is a COM-sensitivity or constant-offset issue
“两者斜率几乎相同(≈0.026°/mm),v1 只是整体多后仰约 2.4° —— 不是质心敏感度问题,是恒定偏置。成因:旧 default 的踝俯仰 trim(−0.0489/+0.0628)本就预补偿了前后质心偏差,换成零位 default 后这份补偿没了 … v0 在真机质心处(−22 mm)的 sim 预测为 −2.31° 后仰,真机实测 2.2~3.1° 后仰 —— 预测精准命中。”
train/RETRAIN_v2.md § 4b. stand_v1 独立验证结果 / 4c. stand_v1b 验收结果 Mirror augmentation over an asymmetric default injects systematic error - symmetrize the default first and verify the transform bit-exact
mirror-augmentation-needs-symmetric-defaultBefore enabling any symmetry augmentation, make every constant inside the observation encoding exactly symmetric, and validate the mirror transform against forward kinematics to machine precision - an unverified augmentation is a new error source, not a regularizer.
Symptom
Mirror data augmentation was about to be added while both default poses (standing_pose, walk nominal_pose) were asymmetric - stale hand-tuned compensations from before a ground re-calibration, with hip_yaw differing 2.40 deg between sides and the foot soles actually tilted (pitch 2.88/1.35 deg, roll -2.47/+0.25 deg).
Context
The observation encodes joint_pos_rel = q - default. Under mirroring q_l -> -q_r, the relation (q-default)_l -> -(q-default)_r holds only if default_l = -default_r; with an asymmetric default, augmentation produces observation pairs that are NOT mirror images, i.e. "default 不对称时做镜像增强会引入系统性错误,比不做还糟" (worse than not doing it). The fix: adopt model geometric zero as standing default (MuJoCo FK verified: sole pitch/roll exactly 0, asymmetry 0.00 deg) and a symmetric crouch for walk (hip -0.25/knee -0.5/ankle -0.25 satisfying hip - knee + ankle = 0 to keep soles flat). The mirror transform itself was verified bit-exact before use: pseudovector vs polar-vector sign patterns (ang vel [-1,1,-1], gravity [1,-1,1], cmd [1,-1,-1]), joint swap-and-negate; FK check that left-foot pose under q equals the mirror of right-foot pose under mirror(q), measured error 0.00e+00.
Change
Defaults symmetrized first (with init heights recomputed by FK), stand policy retrained on the new default so both policies share one default; augmentation enabled only after the FK mirror test passed.
Outcome
stand_v1 achieved exact left/right pairing (l_knee -0.1013 / r_knee +0.1013), six-pair asymmetry 0.0 deg, height fluctuation 7 -> 1 mm, 33% less mean |action|.
Mechanism
Augmentation asserts an equivariance of the observation encoding; any asymmetric constant inside the encoding (the default) breaks the asserted symmetry, so the augmented data teaches a false invariance. Verifying the transform against FK geometry tests the assertion end to end, independent of the training stack.
Applies when
- adding mirror/symmetry augmentation to locomotion training
- defaults or trims were hand-tuned per side at any point
- observations are expressed relative to a default pose
“观测里 joint_pos_rel = q − default。镜像下 q_l → −q_r,要让 (q−default)_l → −(q−default)_r 成立,必须 default_l = −default_r。default 不对称时做镜像增强会引入系统性错误,比不做还糟。… 位置误差与姿态矩阵误差实测均为 0.00e+00。”
train/RETRAIN_v2.md § 2. 前提:default 姿态必须先对称化(不是可选项) / 3. 镜像变换 The latency DR range must cover the measured deployment pipeline - 0-20 ms could not even reach the real 1-2 control steps
latency-dr-covers-measured-pipelineMeasure end-to-end action latency in control steps on your own stack (including cross-process queue boundaries), set the DR range to cover it with margin, and never import a delay count without its control frequency.
Symptom
Action latency was randomized over 0-20 ms (0-1 control step at 50 Hz), but the measured deployment path is 1-2 steps: the deploy process writes the target, an independently running BusWorker picks it up on its NEXT cycle, plus CAN round-trip - the training range could not cover the robot's actual latency at all.
Context
Fix: widen action_latency_s to 0-0.06 (0-3 steps). The external reference's "uniform 6 steps" was explicitly NOT copied - that number depends on his unknown control frequency; locally, a sweep at 0/1/2/3 steps showed walk_v5 survives all with insensitive metrics, so 6 steps "在我们这里没有依据" (has no local basis). The range was set from the measured pipeline with margin, not from a foreign constant.
Change
action_latency_s (0, 0.02) -> (0, 0.06), justified by pipeline analysis (writer/worker cycle boundary + bus time) and bounded by the local latency sweep.
Outcome
The DR band now brackets the true deployment latency; the policy trains against the delay it will actually face instead of a fictional sub-step world.
Mechanism
Latency DR only immunizes against delays inside its support; a range below the physical pipeline guarantees an untrained distribution shift at deployment. The correct range comes from tracing the pipeline's worst case (queueing boundaries + transport), and foreign step-counts are meaningless without the control rate they were measured at.
Applies when
- setting or auditing action-delay randomization
- deployment uses a separate bus/worker process from the policy loop
- importing delay-modeling numbers from other projects
“现行 0~20 ms = 0~1 个 50Hz 控制步, 而实测部署链路是 1~2 步(deploy 写 STATE.target 后, 独立跑的 BusWorker 下一轮才取走下发, 再加 CAN 往返)——现在的区间覆盖不到真机的实际延迟。… 不照抄参考来源的"统一 6 步": 那取决于他的控制频率(未知), 而我们扫过 0/1/2/3 步 … 6 步在我们这里没有依据。”
train/WALK_V7_SPEC.md § ⑤ action_latency_s 0~0.02 → 0~0.06 Four consecutive fixes were each continued from the previous fix's degraded state until the user stopped the ladder - "change parameters, don't stack errors" - rolled back to the last good checkpoint and audited the target geometry first
stop-stacking-roll-back-and-auditWhen successive rungs each start from the previous rung's output and the target symptom does not move, stop, roll back to the last good checkpoint and re-derive the next change from an audit; keep the measurements, discard the stacked remedies.
Symptom
After the real-robot splits, the V2.7 ladder tried to widen the stance: a term swap (A), a new stance knife (b), more iterations (甲), a doubled weight (乙). Stance barely moved while hip yaw ratcheted 46.7 -> 49.9 -> 52.5 deg toward its 60 deg limit.
Context
Each rung started from the previous rung's output. The user ruled on 2026-08-11 that things had gone wrong from V2.7-A: go back to v2_6 and rethink which parameters to change instead of stacking errors.
Change
乙 was killed at start and not counted; the product baseline rolled back to v2_6c model_29399; every measurement and law learned on the ladder was kept ("the data is real; what stacked was the treatment"). Before any new training, a zero-training kinematic audit of the stance targets was run.
Outcome
The audit found the stand_pose target itself rewarding the narrow stance (pose-target-geometric-audit) and showed geometrically why the yawed stance could not be widened with flat feet - so 乙 was proven unnecessary without running it. The next in-lineage attempts still failed, which is what established that the stance is set by the get-up path.
Mechanism
A rung continued from a degraded state inherits its compensations, so each new fix answers the previous fix's side effects; the yaw ratchet was the visible trace of that stacking.
Applies when
- three or more corrective rungs in a row without progress on the target metric
- a side-effect metric ratchets in one direction across rungs
- a new rung is being planned from the latest (not the best) checkpoint
“用户裁:"从 V2.7-A 开始就出问题了,应该回到 2.6 再思考如何改变参数而不是 错误叠加。"认账:A 的补丁 → b 的新刀 → 甲的加时 → 乙的加权,每级都从上级 的**退化状态**续(yaw 46.7→52.5° 的棘轮就是叠加痕迹)。 … 数据是真的,叠加的是处置。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §44 方法论裁定(2026-08-11,用户):V2.7 全阶梯叫停,回滚 v2_6 Guessed joint friction was 2.5x low and damping 5x high - measure, then DR around nominal
friction-measured-not-guessedMeasure frictionloss and damping separately (they need different rigs), put the measured value at DR center, and express DR as an additive band around that nominal - a DR range around a guessed value can exclude the real robot entirely.
Symptom
Old MJCF friction values were invented, not measured; when finally measured, every guessed value was wrong by a large factor in some direction.
Context
Joint friction split into Coulomb (frictionloss, tau_c) and viscous (damping b). Measured with the robot hung from a crane (吊机测) while armature was measured no-load; the two measurements are deliberately separated. Old MJCF: frictionloss 0.05, damping 0.1, DR joint_friction range [0, 0.1] "凭空拍的" (made up out of thin air).
Change
Replace guessed values with measured ones - frictionloss: RS06 0.15 / RS02 0.12 / RS00 0.13 N*m (old 0.05, i.e. 2.5x too low); damping: 0.02 N*m*s/rad on all three motor types (old 0.1, i.e. 5x too high). DR reshaped from an absolute made-up range [0, 0.1] to an additive band around measured nominal: joint_friction_add [-0.05, +0.10].
Outcome
"摩擦定稿(与 armature 一起, plant 参数第一次全部来自实测)" - friction frozen as part of the first fully-measured plant; DR now brackets a measured truth instead of spanning an invented interval.
Mechanism
Coulomb friction and viscous damping have opposite behavioral signatures (constant-torque threshold vs velocity-proportional drag); guessing both wrong in opposite directions gives a plant that is simultaneously too easy to start moving and too hard to move fast. DR centered on a wrong nominal makes the policy robust to a family of plants that does not contain the real one.
Applies when
- plant friction/damping values have no measurement provenance
- DR ranges are absolute intervals rather than bands around a nominal
- policy is over- or under-damped on hardware relative to sim
“测关节摩擦。吊机测,而armature应该空机测试。… frictionloss τ_c (N·m) │ 0.15 │ 0.12 │ 0.13 │ 0.05(低 2.5×) … damping b (N·m·s/rad) │ 0.02 │ 0.02 │ 0.02 │ 0.1(高 5×) … DR │ joint_friction_add: [−0.05, +0.10] 叠标称 │ 旧 [0, 0.1] 凭空拍的”
Experience.md § 摩擦定稿表 (lines 12-25) Close a question with an audit, then freeze the wording - later symptoms may not reopen it without new hard evidence
frozen-verdicts-semantic-boundariesWhen an audit closes a hardware-vs-policy question, record the closing evidence, freeze a citable wording for future recurrences, and set the reopening bar explicitly; separate robustness perturbations from plant-truth questions so a DR rung's failure can never silently reopen a closed measurement.
Symptom
Recurring directional bias on the robot kept re-suggesting "maybe the hardware/COM/mechanics are asymmetric", threatening to re-litigate questions that audits had already closed - burning attention each time a descendant policy leaned or drifted.
Context
Two boundary decisions were written as permanent: (1) semantic separation - "S2④ COM ±20mm = 纯鲁棒性扰动,不再承担「解释真机后仰」任务" - if the COM-DR rung degrades, the ONLY allowed conclusion is "policy insufficiently robust to COM uncertainty"; reopening "is the CAD COM wrong" is forbidden because the mass audit was completed and closed (@63f9212). (2) a frozen wording for chirality, to be quoted verbatim whenever left/right bias appears in later rungs: observed directional bias = policy-level spontaneous symmetry breaking; plant asymmetry = no supporting evidence after the mass + model symmetry audit; mitigation candidate pi_sym queued, not blocking. The evidential basis was quantitative: the root policy was perfectly symmetric under +/-6 N*s pushes (40/40) while descendants broke (17/40, 13/40) - "手性是 S2 训练中获得的, 根没有; 机械侧已双 PASS 关案, 不重开".
Change
Closed questions carry (a) the audit commit that closed them, (b) a frozen citable wording for recurrences, and (c) an explicit evidence bar for reopening ("无新硬证据不得重开").
Outcome
Later chirality observations (C2's 15 pp turn gap, hip_roll drift bias) were handled as policy-lineage properties with policy-side mitigations, without a single hardware re-audit cycle.
Mechanism
Symptom classes recur under different guises; without a frozen verdict each recurrence re-runs the same expensive investigation and risks a different (worse-informed) conclusion. Freezing verdict plus wording converts recurring symptoms into citations, while the evidence bar keeps the closure honest rather than dogmatic - the root/descendant symmetry comparison is what makes "it's the training, not the machine" checkable at any time.
Applies when
- a recurring symptom keeps suggesting an already-audited hardware cause
- writing conclusions for a completed calibration/audit
- a DR rung's degradation invites re-measuring the plant
“若 S2④ 退化,结论只能是「当前 policy 对 COM 不确定性不够鲁棒」,不得重开「CAD COM 是不是错了」… 手性冻结表述 … Plant asymmetry: no supporting evidence after mass + model symmetry audit … 无新硬证据不得重开机械不对称”
train/OMNI_V0_SPEC.md § 4. 语义分界与手性冻结表述(2026-08-07 用户定,永久) Run acceptance under measured contact parameters - honest condim/torsional-friction flipped a false PASS into a real-matching FAIL
eval-plant-honesty-contact-paramsPin the evaluation plant's contact model to measured values (contact dimension, torsional/rolling friction, mu) before trusting any gate that involves slip, impact, or drift - a gate can only fail a policy for physics its simulator contains.
Symptom
walk_v5 passed the old acceptance battery yet failed on the real robot (footfall force, drift, kicking) - the evaluation plant was flattering the policy.
Context
The battery was re-run under "honest contact parameters" - condim 4 (adding torsional contact) with measured torsional friction 0.035 - and v5 then FAILED exactly the rows corresponding to its real problems: heading 185 deg (limit 30), support-foot yaw slip 284 deg (limit 80), landing force 1.72x (limit 1.5x), suspended tilt 45.9 deg (limit 10). The slip physics depends on torsional friction, which the default contact model (condim 3) does not even simulate - a slip problem is invisible to an evaluator that cannot represent yaw friction at the foot. Term-sizing measurements for the new rewards were likewise taken under the same honest parameters (cmd 0.45, skipping the 5 s start transient).
Change
Acceptance harness pinned to condim 4 / torsion 0.035 (measured); verdicts issued under defaults declared non-citable for these rows.
Outcome
Sim acceptance verdicts began agreeing with hardware ("现在失败, 与真机一致"); the v6 fixes could be developed and validated against an evaluator that could actually see the disease.
Mechanism
An evaluator is a plant model too: contact dimensionality and friction values decide which failure modes exist in the simulation at all. Evaluating under default contact parameters tests the policy in a world where its real failure is physically impossible, producing structurally false PASSes.
Applies when
- sim acceptance passes policies that fail on hardware
- slip/drift/impact gates run under default simulator contact settings
- setting up a cross-simulator evaluation harness
“accept_v2.py 已加三条判据, walk_v5 在诚实的接触参数下(--condim 4 --torsion 0.035)现在失败, 与真机一致:直行 15s 航向累计 <30° | 185° ✗ … 落脚力峰值 <1.5× 体重 | 1.72× ✗”
train/WALK_V6_MINIMAL.md § 5. 验收 The walk phase machine structurally cannot express flight - rebuild the representation for duty < 0.5, teach flight with a mask tax, never a cliff bounty
phase-machine-structural-limitsWhen a new gait changes the contact pattern's structure, audit whether the phase/mask representation can express it and rebuild the representation if not; teach the new contact pattern with graded mask-mismatch pressure and count it in acceptance with artifact-proof definitions (minimum segment length), never with cliff bounties.
Symptom
Running requires both feet airborne, but the walk-era phase machine switches legs by the sign of sin(phase) - with duty < 0.5 the two swing windows must OVERLAP during flight, which a sign-switching representation cannot express at all.
Context
The run phase machine was re-architected rather than patched: per-leg phases (left = phi, right = phi+0.5 mod 1) with leg_phase < duty defining stance, aligned to the walk sin convention at duty=0.5 so the machines agree where their domains overlap. Flight is taught by the SAME mechanism that once cured foot-dragging, direction reversed: in the two planned flight windows the contact mask is (0,0) and feet_contact_number_duty charges -0.3 per foot still on the ground - a mild ~0.16/step tax, deliberately NOT a cliff: "悬崖式腾空奖励诱发跳跃 hack,v4-clearance 家族老课文". The reference shape (half-sine bump over swing progress) is zero at window boundaries by construction, eliminating the clearing-window that the C4 probe measured to cost 13-19% on non-sinusoidal references. The shape self-check ("零代价选项是什么") was run on three behaviors: standing pays ref everywhere (known cmd=0 stepping risk, booked), walking pays only the flight-window tax, proper running collects full marks.
Change
New rewards.py run section (leg_phase_duty / stance_mask_duty / ref_run / clearance_run / contact_duty) with the walk versions untouched byte-for-byte; flight acceptance metric defined with a segment-length floor (>=40 ms to count) so numeric contact flicker cannot fake flight.
Outcome
Flight became expressible and taught by a calibrated mild pressure; the walk lineage's phase code stayed frozen as its own contract.
Mechanism
A phase representation defines which contact patterns exist in the reward's vocabulary; duty cycling below 0.5 introduces states (double-flight) outside a half-period sign convention's language, so no weight tuning can teach them. And rare desirable events taught by cliff-shaped bounties invite hacks (jumping in place); the graded mask tax prices the planned pattern without creating a jackpot.
Applies when
- extending a walking stack to running/jumping (duty < 0.5)
- a desired contact pattern never appears despite reward increases
- defining flight/contact acceptance metrics
“duty<0.5 时摆动窗 (1−duty)T > T/2,两腿摆动窗在腾空段重叠 —— sin 符号切腿的机制结构上表达不了"双脚同时在空中"。… feet_contact_number_duty 对"还踩着地"持续 −0.3/脚 —— 与 walk 治拖地同一机制,方向相反。不腾空的税 ~0.16/步 … 梯度温和不构成悬崖(悬崖式腾空奖励诱发跳跃 hack,v4-clearance 家族老课文)。”
train/RUN_V0_SPEC.md § 5. 相位机设计 Freeze the deployment contract, stamp every export, and let an automated checker catch wiring bugs
contract-freeze-and-checkerFreeze and fingerprint the policy I/O contract; ship contract changes as new versioned profiles that leave old artifacts bit-identical; and extend the automated contract checker with every pipeline change, forcing the new path to execute in the check.
Symptom
Contract-level changes (observation layout, action pipeline) are where silent sim/real divergence is born; two real wiring bugs appeared the one time the action pipeline was extended.
Context
The 215-dim observation contract was frozen ("纪元 3,三机 digest" - an era number plus a digest agreed across three machines); proposals that would break it (e.g. a GRU memory) were rejected on contract grounds. Every exported ONNX is stamped and verified with a manifest (onnx_manifest --stamp / --verify), and deployment refuses mismatched combinations. When C4 added the lateral feed-forward, it went in as a NEW profile (omni_ff) leaving the existing omni profile's behavior bit-identical; the checker (check_contract) was extended to force the feed-forward path to actually execute (cmd_vy=0.13) and promptly caught two genuine bugs: (1) re-clamping with soft_joint_pos_limits after the feed-forward (0.23 rad deviation) instead of reusing the parent's clip; (2) indexing processed actions by asset.joint_names instead of the action term's own contract-ordered _joint_names, which landed the feed-forward on the wrong joints (l_hip_yaw / r_ankle_pitch).
Change
Contract discipline as implemented: frozen dims + digest; manifest stamping and refusal; contract changes only via new versioned profiles; checker updated in the same commit as any pipeline change, with inputs chosen so new code paths are exercised.
Outcome
Both wiring bugs caught before any training or deployment ("两个都是 check_contract 当场抓出来的 —— 这次它值回票价"); old deployments provably unaffected by the new profile.
Mechanism
The contract is the only interface the policy and robot share; freezing plus fingerprinting makes divergence detectable, and an executable checker turns "the contract holds" from a belief into a test - but only if its inputs actually drive the new code path.
Applies when
- modifying the action or observation pipeline of a deployed policy
- exporting policies for hardware
- proposals that would change observation dims or history structure
“契约校验抓到的两个真错误(记账,别再犯):1. 前馈后误用 soft_joint_pos_limits(URDF 限位 ×0.9)重钳 → 0.23 rad 偏差 … 2. 用 asset.joint_names 索引 _processed_actions → 前馈落到 l_hip_yaw/r_ankle_pitch 上 … 两个都是 check_contract 当场抓出来的 —— 这次它值回票价。”
train/C_LADDER_RUN.md § 3j. 契约级改动 / 契约校验抓到的两个真错误 A hardware run without its log is an anecdote - the first real get-up's policy, gain profile and log were never recorded, two CSVs stayed "to be reported", and runbook commands wrote different policies' logs under one copied filename
hardware-log-is-the-attribution-inputMake the log part of the run: name it from the policy and conditions automatically (never by hand-copied filenames), record the policy digest and gain profile inside it, include what the open questions need (torque, joint positions and targets), and treat a session without a collected log as incomplete.
Symptom
The recovery line's oldest open question - whether Isaac or MuJoCo reads torque demand correctly - was waiting on real-robot logs that never arrived, and the verdicts that did arrive could not be tied to files.
Context
deploy_policy writes a CSV per run (--log); the runbook's own analysis snippet reads its joint-position, target and action columns (q_, tgt_, act_), and the recovery hanging checklist asks for torque and joint logs for the whole run, to be compared with simulation. The first real get-up (08-09): policy, gain profile and log "to be recorded later". The first real A/B (08-11): v2_5b's result and both policies' CSVs "to be reported". In the runbook's walking commands, three runs of two different c4 policies log to real_s1e_pw08_teleop_0808.csv, and s1e and s2e_fric runs log to real_c2_700_pw08_teleop_0808.csv - filenames copied from other commands.
Change
None recorded; the spec kept listing the open-loop comparison as waiting for real logs.
Outcome
No real-robot log appears in the recovery spec through §50, so the simulator disagreement stayed unresolved and hardware verdicts stayed unattached to data.
Mechanism
Attribution needs the run's identity (policy digest, profile, conditions) and its signals in one artifact; a filename copied from another command mislabels the file, and a log not collected at the session is rarely collected later.
Applies when
- planning a hardware session whose result should settle a sim question
- log filenames are typed or pasted by hand
- hardware feedback arrives as prose without files
“python tools/deploy_policy.py --policy train/policies/omni_c4_ff800_pj.onnx … --log train/real_logs/real_s1e_pw08_teleop_0808.csv … q,t,a=d[:,c("q_")],d[:,c("tgt_")],d[:,c("act_")]”
RL系统/FOLLOW THIS copy 2.md § Walk 遥控 / S2 / csv 分析片段 (operator runbook, undated) A time gate that had cured one lineage's rushing made the from-scratch lineage trade away its stance width twice (0.364 -> 0.235 m, 0.355 -> 0.251 m) - its disease was absent there, so the fix was retired and the pre-gate checkpoint shipped
time-gate-vs-wide-stance-retire-the-fixCarry a fix into a new lineage only if its disease is present there; a mechanism that cured one lineage can be net negative in another, and when doubling a term's weight recovers almost nothing, treat the two objectives as structurally in conflict and remove the one whose purpose is gone.
Symptom
V3.1's phase 2 (the 3 s zero gate on standing income, continued from P1b) kept 100% success on every friction level and slowed the get-up, but the lateral stance drifted 0.364 -> 0.235 m and hip yaw crept to 57 deg against its 60 deg limit. With the width band's weight doubled (P2c, after P1c) it drifted again, 0.355 -> 0.251 m, below the pre-registered 0.30 m failure line.
Context
The zero gate had been introduced in V2.5/V2.5b to slow the old lineage's get-up. In V3.1 the rushing was already absent: P1c got up in 0.90-1.06 s with a worst torque ratio of 73.3%, better than the stamped v2_6c, because the full beta curriculum, second-difference smoothing and pull curriculum had cured the violence inside training.
Change
Recorded as a candidate law with two data points - the zero gate and a wide stance are mutually exclusive here - and the zero gate was removed from the V3.1 recipe. P1c (the pre-gate checkpoint) went through the full stamp-level acceptance instead.
Outcome
P1c passed everything: all six criteria, lateral stance 0.355 m, foot tilt P75 2.0 deg, mu {1.0, 0.8, 0.6, 0.4} x 10 seeds all 100%. recovery_v3_1p1c.onnx was stamped and pushed to the robot channel.
Mechanism
The zero gate moves the income toward "stay stable until the end", and under low-friction DR a wide stance has a slip tail, so survival outbids the width band; doubling the band's price bought back only 0.016 m - an auction that does not converge signals structural conflict, not an under-priced term.
Applies when
- porting reward mechanisms from an old lineage into a fresh recipe
- a width, margin or posture metric erodes during a late training phase
- a weight increase produces a negligible change in its target
“**定律候选(二实证):归零门 × 宽站互斥**。 … 加价翻倍只挽回 0.016,竞拍不收敛)。 … **归零门是 v2_5 血统的历史包袱,对 V3.1 配方是净负资产,P2 阶段除名 —— P1c 即终点形态**。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §49 终验(2026-08-14) Every rung gets written stop criteria - hit any one, stop; tightened when priors say results should come fast
preregistered-stop-criteria-per-rungFreeze per-rung stop criteria (old-skill floors, new-skill deadline, oscillation signature, known pathology signatures) before training, stop on first hit - and shorten the deadline in proportion to how fast your mechanism says results should appear.
Symptom
Continued training past the point of degradation had previously destroyed capabilities (C1 trained away the root's backward skill); without hard stop rules, sunk-cost reasoning keeps runs alive too long.
Context
Standard rung protocol - eval_c_matrix every 100 iters at 5 seeds with a fixed criteria list, frozen before training ("开训前写死,事后不许改"): (1) stand or vx+0.15 at <=3/5 for two consecutive points; (2) vx+0.15 tracking <70% for two consecutive points (vs recorded root baseline); (3) oscillation signature - survival repeatedly crossing zero between adjacent checkpoints, stop on first occurrence, do not wait for confirmation; (4) new-skill-no-progress deadline (e.g. wz tracking <30% or still same-signed after iter 400); (5) a known lineage pathology signature (s1c arm-B: scatter -> half-recover -> collapse).
Change
Stop budgets scale with prior knowledge: when C4-redo4's feed-forward was already proven open-loop, the no-progress deadline was tightened from +500 to +100 iters ("前馈是开环就给 71~96% 的 … 若 +100 还没有 … 不值得再烧").
Outcome
Multiple rungs were stopped exactly on criterion (C4-redo criterion 4 at iter 1200; redo2/redo3 at absolute 900), converting each into a clean hypothesis test instead of a drifting run; no rung burned its full cap on a dead hypothesis.
Mechanism
Degradation of retained skills is a lineage-level injury that later training often cannot undo, so detection latency is capital loss; and a stop rule written before the run cannot be bent by hope. Tightening deadlines when priors predict immediate results converts "no result yet" into evidence against the mechanism.
Applies when
- starting any resumed/curriculum training rung
- deciding whether to keep training a run that shows early regression
- a mechanism-backed change should produce results immediately
“每 100 iter eval_c_matrix.py --seeds 5,命中任一即停 … 存活在相邻 checkpoint 间反复跨越 0(出现即停)… 收紧版:绝对 iter 900(= +200)时 vy±0.10 跟踪仍 <30% 即停”
train/C_LADDER_RUN.md § 3h. 预注册停梯判据(开训前写死,事后不许改) mj_objectVelocity returns inertial-principal-axis frame - one API assumption poisoned eval and observations for a whole line
body-frame-velocity-api-auditVerify every frame-sensitive API against a hand-computed truth (rotate raw qvel yourself, or command a known world velocity and check where it lands) before trusting any evaluation or observation built on it - especially when a model's inertial frame is rotated from its body frame.
Symptom
Sidewalk vy read ~0 under every condition; separately, whole-policy performance was mysteriously mediocre in sim2sim while training-side numbers looked fine. Four training rungs were declared FAIL partly on these readings.
Context
base_link's URDF inertial frame is rotated 90 deg about x relative to the body frame (iquat = [0.7071, 0.7071, 0, 0]). mj_objectVelocity(flg_local=1) rotates into ximat - the inertial principal-axis frame - not the body frame, and returns center-of-mass point velocity, not body-origin velocity. Consequences measured: the "vy" column was actually vertical velocity vz (walking at cmd 0.25: old reading +0.0093 vs true -0.0424); the angular velocity fed to the policy in sim2sim was [wx, wz, -wy] - a different quantity than Isaac and the real IMU provide. RMS check over 8 s of walking: y/z axes swapped between v6[:3] and the qvel truth.
Change
Fixed sim2sim and both probes to compute ang_b = qvel[3:6] and lin_b = xmat.T @ qvel[0:3] (identical quantity to Isaac's root_ang_vel_b / root_lin_vel_b), with a standalone reproduction script (frame_bug_repro_0809.py).
Outcome
Re-scoring the "failed" C4 lineage under correct coordinates reversed the verdicts: c4r4 checkpoints showed vy 80-126% tracking (old reading: +/-2%) and vx+0.30 at 91-95% where the old metric said 0/5 - the bad frame both mis-measured vy and, via corrupted policy observations, systematically depressed all measured performance. Final product passed 260/260 cells.
Mechanism
A simulator API's frame convention is part of the observation contract; when the model's inertial frame is rotated relative to the body frame, frame-agnostic use of a "local" velocity silently permutes axes. Feeding a policy an axis-permuted angular velocity is an observation corruption that degrades behavior everywhere, not just on the axis being studied.
Applies when
- building or auditing a cross-simulator evaluation harness
- one measured axis reads near-zero under all conditions
- sim2sim scores are inexplicably worse than training-side metrics
- URDF/MJCF inertial frames are rotated relative to body frames
“base_link 的 iquat = [0.7071, 0.7071, 0, 0] … mj_objectVelocity 用的是这个 … 喂给策略的 base_ang_vel 是 [wx, wz, −wy] —— MuJoCo 侧观测与 Isaac / 真机 IMU 不是同一个量;vy_mean 报的是竖直速度 vz —— 前进 cmd 0.25 时旧读数 +0.0093,真值 −0.0424。”
train/C_LADDER_RUN.md § 3l. ⚠️ mj_objectVelocity 读的是惯性主轴系 / 3m. 一 bug 坐实 The action-delay was implemented as lerp - beyond one step it extrapolated BACKWARD, so a whole lineage trained on a fictitious actuator
latency-lerp-reverse-extrapolationUnit-test plant-model code (delays, filters, randomizers) against hand-computed truth across its FULL configured range, not just the nominal case - a delay must be a queue, and any interpolation used outside [0,1] is a silent plant corruption that training will faithfully absorb.
Symptom
Every walk/stand model up to v11 had been trained on a silently wrong plant: the action-latency implementation lerp(cur, prev, lag) is only an interpolation for lag <= 1 - at lag 3 it computes 3*prev - 2*cur, a REVERSE extrapolation. With the configured (0, 0.06) s at 50 Hz (lag in [0,3]), about 2/3 of environments were adapting to actuator dynamics that do not exist.
Context
Listed as evidence item #1 for the full restart: "全部旧模型训在错误 plant 上" and the head suspect for the real robot's wild kicking. The fix replaced it with a true FIFO delay line (commit 7f13793) plus its own regression test (tests/test_action_latency.py) - but every exported ONNX predated the fix, which is part of why the lineage was frozen rather than patched.
Change
Delay implementation rewritten as an honest FIFO with unit tests; the restart baseline trained on the corrected plant from day one.
Outcome
A generation-scale training investment was revealed to have a corrupt plant underneath; the class of bug (plausible-looking math that silently changes meaning outside its valid range) got a permanent test.
Mechanism
lerp(a, b, w) leaves the segment for w > 1; used as a delay it fabricates high-gain inverted dynamics precisely in the largest-delay draws, so the policy learns compensation for an actuator that cannot exist - and DR then trains robustness to the artifact rather than to reality. No training metric can catch this: the sim is self-consistent, just wrong.
Applies when
- implementing or auditing action delay / filtering in a trainer
- a lineage behaves as if compensating dynamics nobody modeled
- deciding whether old checkpoints are salvageable after a plant bug
“动作延迟旧实现 lerp(cur, prev, lag) 在 lag>1 时是反向外插(w=3 → 3·prev−2·cur),配置 [0,0.06]s@50Hz 即 lag∈[0,3],约 2/3 env 在适应不存在的执行器动态。7f13793 已换真 FIFO,但所有 ONNX 均训于修复之前 —— 真机"乱踢"的头号嫌疑。”
train/OMNI_V0_SPEC.md § 0. 为什么从零 (1) A reward on a quantity the actor cannot observe teaches "produce less of it", never "correct it" - closed-loop correction needs an outer loop
reward-observability-limitBefore adding a reward, check the actor can observe (or infer) the quantity: unobservable-error rewards buy only average suppression - route correction tasks to an outer loop whose commands stay in distribution, and do not break a frozen contract to add an observation a deploy-side loop can supply.
Symptom
Heading kept drifting despite world-frame yaw rewards, and a reviewer proposed heading-error rewards - raising the question of what yaw shaping can even teach this actor.
Context
The adopted architectural verdict: the actor's 45-dim base observation cannot see accumulated heading at all - projected_gravity is invariant to rotation about the gravity axis, and omega_z is a rate, not an angle. World-frame yaw-rate rewards are therefore privileged shaping that can only teach "少产生旋转" (generate less rotation), never "偏了以后拉回原线" (pull back to the line after drifting) - the policy cannot represent the error it would need to correct. The S1 gate (<=5 deg / 10 s) demands exactly the former, so the stack is right for its gate; active heading correction is assigned to the deployment outer loop (--heading P-loop converting heading error into in-distribution wz commands) plus small-wz training - and the 215-dim contract is explicitly NOT extended with a heading observation ("契约不加 heading 观测,冻结不动"). The reviewer's companion bias hypothesis was adjudicated with data: drift is bimodal - a basin mechanism decides whether you leave (seeds vary +/-16-46 deg vs -385 to -391 deg), and once out, rotation direction is constant (weight chirality; candidate root: the phase clock always swings left first).
Change
Yaw shaping kept as rate-tracking (three-layer stack); heading correction owned by the deploy outer loop; contract frozen; the "which behaviors need an outer loop" question settled by observability analysis rather than reward tuning.
Outcome
Stopped a contract change and a futile reward direction; drift work split correctly into rate-suppression (trainable) and error correction (outer loop), consistent with the earlier measured 10x drift reduction from the deploy-side loop.
Mechanism
A policy can only condition on its observation sigma-algebra; rewards on functions outside it shift the marginal action distribution (open-loop average effects) but cannot create feedback on the unobserved variable. Whether to add an observation, an outer loop, or accept average-shaping is decided by the task's gate: suppression gates need shaping, correction gates need the variable in some loop's view.
Applies when
- adding rewards on accumulated/世界-frame quantities (heading, position)
- deciding between a new observation, an outer loop, and shaping
- a drift symptom persists across reward-weight changes
“actor 的 45 维基座观测不到累计航向(projected_gravity 对绕重力轴旋转不变,ωz 是速率不是角度)——世界系 yaw 奖励是特权塑形,只能教「少产生旋转」,不能教「偏了以后拉回原线」。… 主动纠偏闭环 = S3 把小 wz 进分布 + deploy --heading 外环 … 215 契约不加 heading 观测,冻结不动。”
train/OMNI_V0_SPEC.md § 3. 评审④判决(2026-08-06,S1.3 开训前) Armature must be N^2 x rotor inertia, never 0 - measure it no-load
armature-n2-rotor-inertiaEvery geared actuator carries N^2 * I_rotor of reflected inertia at the joint; set armature from a no-load measurement, never leave it 0 and never guess it.
Symptom
Sim joints accelerate more easily than real joints; old MJCF had armature = 0 (rotor reflected inertia entirely unmodeled), a systematic sim2real gap on every joint.
Context
Original hand-written MJCF plant used armature 0. The team derived and then measured the correct value: torque needed at the rotor is I_rotor * N * alpha; after the N:1 gearbox the output shaft "feels" an extra N^2 * I_rotor of inertia. With a 9:1 reduction that is an 81x amplification of the rotor inertia, far too large to ignore.
Change
Set per-motor armature from no-load (motor out of the robot) measurement instead of 0: RS06 = 0.0070 kg*m^2, RS02 = 0.0032 kg*m^2, RS00 = 0.0015 kg*m^2. Landed together with measured friction as the first fully-measured plant parameter set.
Outcome
Plant parameters "第一次全部来自实测" (first time all from measurement); became the frozen plant baseline for all subsequent training generations.
Mechanism
Reflected inertia scales with the square of the gear ratio: the rotor spins N times faster than the joint, so its kinetic energy (and the torque needed to accelerate it) appears N^2 larger at the output. Omitting it makes simulated joints unrealistically fast/light, so policies learn action rates the real actuator cannot deliver.
Applies when
- building or auditing a simulation plant model for a geared/QDD actuator
- sim policy moves joints faster or snappier than the real robot can
- MJCF/URDF review shows armature or rotor inertia set to 0 or a default
“armature 转子反射惯量有问题 在sim里面一定要处理 不能是0,空机测试。转子处需要的力矩 = I_rotor × N × α 经减速箱放大 N 倍后 = N² × I_rotor × α 所以输出轴"感觉到"多了一个 N² × I_rotor 的惯量。 这就是 armature。… 关键是那个平方。减速比 9:1 就放大 81 倍。”
Experience.md § # armature 转子反射惯量有问题 (line 9) Fine-tuning through a reward-table change was falsified (scatter, half-recover, collapse) - continuation training is legal only with the reward frozen
fine-tune-reward-change-falsifiedNever fine-tune through a reward-table change - retrain from zero; reserve checkpoint continuation for frozen-reward plant/DR widening, reset noise_std when branching, and watch for the scatter/half-recover/collapse signature as the abort trigger.
Symptom
The s1c A/B experiment: arm B fine-tuned from an existing checkpoint under the revised reward (same contract, same network, changed reward + small DR) and failed with a characteristic signature - scatter, half-recover, fall back ("打散→半恢复→摔回"); arm A trained from zero under the same config won decisively (full shaping lifted swing to 21.6 mm within 500 iters; shipped at 5500).
Context
Verdict recorded: "从零 + 强塑形是本机唯一验证过的发育路径" (from-zero plus strong shaping is this machine's only validated development path). The signature became a standing stop criterion in every later rung that touched a reward ("s1c B 臂签名,出现即停"). Crucially the boundary of the law was drawn explicitly when S2 continuation training was proposed: "当年证伪的是「奖励表中途改版的 fine-tune」… S2 续训奖励表全程冻结、只逐级加宽 plant/DR,属另一类" - continuing a checkpoint with the reward FROZEN while widening plant/DR one rung at a time is a different class and was allowed (and then worked, powering the whole S2/C lineage) - with the honest fallback that if frozen-reward continuation ever collapses, that rung retrains from zero and the doctrine gets re-examined with data. Fine-tune arms also need mechanical care: reset the checkpoint's collapsed noise_std (terminal 0.033 "会杀死探索") and account for iteration counters re-zeroing (curriculum gates fire immediately).
Change
Reward changes and lineage continuation permanently separated: reward revisions -> from-zero retrain; plant/DR widening -> frozen-reward continuation with per-rung gates; the B-arm signature promoted to a universal tripwire.
Outcome
No later reward revision was attempted by fine-tune; frozen-reward continuation carried S2 (PD/COM/friction rungs) and the C command ladder successfully from the s1e root.
Mechanism
A trained policy sits in an optimum of its reward's geometry; changing the reward moves the optimum but leaves the policy's exploration noise near-zero and its value function calibrated to the old returns - it disassembles the old solution faster than it can assemble the new one. Widening DR under a frozen reward instead keeps the optimum's identity and asks only for local robustification.
Applies when
- proposing to fine-tune an existing policy under a revised reward
- planning a robustification ladder from a validated checkpoint
- a continued run scatters then partially recovers then collapses
“B 臂 fine-tune 证伪(打散→半恢复→摔回——从零 + 强塑形是本机唯一验证过的发育路径)。… 当年证伪的是「奖励表中途改版的 fine-tune」(B 臂,塑形突变致终盘摔回);S2 续训奖励表全程冻结、只逐级加宽 plant/DR,属另一类;若 s2_lag1 续训本身塌方,回退方案 = 该级从零重训,续训教义再议(拿数据说话)。”
train/OMNI_V0_SPEC.md § 3. S1.3 / 4. 与 s1c fine-tune 证伪的关系 Changing the gait clock silently flipped a hardwired threshold's meaning - write derived constants as expressions
derived-constants-must-track-their-baseBefore changing any base parameter (clock, control rate, scale), enumerate every constant derived from it and every constant that must NOT change; convert derived literals into expressions of the base so the next change cannot silently flip a term's meaning.
Symptom
Slowing the clock 0.40 -> 0.50 s would have silently inverted the feet_air_time threshold's semantics: the 0.25 s threshold was hardwired, so at ct 0.40 the swing window (~0.20 s) sat below it (constant pressure to lengthen strides), while at ct 0.50 the window (~0.25 s) equals it - the term's meaning flips from "push longer" to "neutral" with no code error anywhere.
Context
The clock change audit walked every dependent quantity: most followed automatically (joint_pos_ref / clearance / contact_number cycle_time params, gait_phase observation, deploy/sim2sim/policy_io, export) - wiring confirmed, zero hand edits; the air_time threshold was the one hardwired constant, fixed by preserving the RATIO: 0.25 -> 0.3125 = 0.625 x ct, with the recommendation to commit it as the expression 0.625*ct "一劳永逸" (solved once and forever). The same audit also listed what must NOT follow the clock (50 Hz control rate, physics dt/decimation, 47-dim contract, action_latency absolute seconds, PD/torque limits) - the change's blast radius stated in both directions.
Change
feet_air_time threshold re-expressed as a fraction of cycle_time; auto-following vs must-not-change lists written into the spec for the clock migration.
Outcome
The clock migration (v10, repeated in v11) carried no silent semantic flips; the expression form removed the trap for every future clock change.
Mechanism
Constants derived from a base parameter encode a ratio at their birth; storing the evaluated number severs the dependency, so changing the base leaves stale semantics with no failing test. Expressions preserve the intent; and an explicit both-directions dependency list (follows / must-not-follow) is what makes a base-parameter change reviewable.
Applies when
- changing gait clock, control frequency, or units
- a reward threshold interacts with a phase/window duration
- config audit finds literals that encode ratios
“feet_air_time 阈值 0.25 是写死的,不跟 ct 走——0.40 时摆动窗 ~0.20s<0.25(恒拉长压力),0.50 时摆动窗 ~0.25s≈阈值(语义翻转)。按比例保原压力:0.25 → 0.3125(=0.625×ct;建议直接写成 0.625 * ct 表达式,一劳永逸)。”
train/WALK_V10_SPEC.md § 3. T —— 慢时钟 (训练侧必做一件) A ratio metric flipped the verdict - spectral share rose while absolute high-frequency energy fell 16%
ratio-metrics-need-absolute-checkNever compare share/percentage/centroid metrics across conditions whose totals differ; pair every ratio with its absolute numerator before issuing a verdict, and log retracted judgments so they are not re-derived.
Symptom
walk_v6 was provisionally judged "more jittery" than v5 because the joint-velocity spectral centroid rose 2.91 -> 3.62 Hz and the >4 Hz energy share rose 12.6% -> 17.8%.
Context
Absolute measures said the opposite: first differences of actions fell 1.54 -> 1.31, second differences 2.55 -> 2.19, and absolute high-frequency energy fell 16% (0.490 -> 0.413). The shares and centroid rose only because low-frequency content fell even more - the denominator shrank. The interim judgment was retracted in writing so it would not be reused.
Change
Metric discipline noted: "占比类指标在总量变化时不能直接比较" - share/ratio metrics are not comparable across conditions when the total changes; verdicts about smoothness must cite absolute energies or difference norms.
Outcome
v6 correctly classified as smoother, not jitterier; the retracted judgment logged under "被推翻的一个中间判断(记下来免得复用)".
Mechanism
A ratio confounds numerator and denominator; any intervention that removes low-frequency content raises every high-frequency share without adding a single joule of jitter. Only absolute quantities support cross-condition comparison when totals move.
Applies when
- comparing smoothness/jitter/spectral metrics across versions
- any percentage-based metric moves after an intervention
- writing an eval report that includes normalized quantities
“我一度说"v6 动作更抖" … 错了: 动作一阶差 1.54→1.31、二阶差 2.55→2.19 都在降 … 谱质心升高只是因为低频成分掉得更多, 绝对高频能量实际下降 16%(0.490→0.413)。占比类指标在总量变化时不能直接比较。”
train/WALK_DIAGNOSIS.md § 过程中被推翻的一个中间判断(记下来免得复用) Fix the task first, harden the plant second - DR budget spent on a dying task is wasted
task-shaping-before-plant-hardeningFreeze the task/command distribution before spending DR budget on plant robustness; if the task will still change, schedule plant hardening as a final pass and book the interim robustness gap explicitly.
Symptom
Tempting default ordering was to keep the plant-hardened (S2) lineage and teach it new commands; but the S2 plant adaptation had been earned on the straight-walk task, and the new omni tasks (sidewalk, in-place turn) use completely different contact patterns.
Context
The team had direct evidence that DR robustness is a budget that gets reallocated when the data distribution changes ("push/μ 两轮已实证 DR 预算有限且会被重分配") - robustness trained under one task/command distribution does not persist when training continues under another.
Change
Ladder order set to: first C (task shaping - add command modes until the task family is final), then a second S2 pass (plant hardening) on the C product. The plant-robustness gap this creates mid-ladder is accepted and booked explicitly ("此处不欠账" - the debt is assigned to the second S2 pass, not denied).
Outcome
The first S2 pass was not wasted: its laws (kd bandwidth <-> low mu, push need not be trained, ground mu need not be trained, bistability) let the second pass drop from five rungs to three. The C ladder itself ran on the softer plant band without incident.
Mechanism
DR robustness is carried by the policy's visited-state distribution; changing the task changes that distribution, so robustness bought under the old task partially dissolves. Hardening before the task is final means paying for robustness on states that will no longer be visited - "给一个即将不存在的任务花预算" (spending budget on a soon-to-not-exist task).
Applies when
- deciding ordering between skill/command expansion and DR hardening
- a hardened lineage is proposed as the root for a task change
- robustness regressions appear after adding new command modes
“S2 的 plant 适应是为直行步态调的,C4 侧走/C3 原地转是完全不同的接触模式,先硬化再改任务 = 给一个即将不存在的任务花预算(push/μ 两轮已实证 DR 预算有限且会被重分配)。故顺序改为 先 C(任务定型)→ 再 S2(plant 硬化)。”
train/C_LADDER_RUN.md § 0. 决策逻辑 = 短板可不可恢复 (末段) An outer heading P-loop at deploy cut drift 10x because its output stays inside the trained command band - then training was aligned to it
deploy-heading-loop-and-align-trainingFix drift-class problems first with an outer loop whose output provably stays inside the trained command band; when adopting it permanently, align the training command generator to the deployment's actual command mixture (feedback-driven AND constant), matching law, gain, and clip exactly.
Symptom
Persistent heading drift on straight-line walking (v6 net yaw 60.3 deg over 15 s) that reward-side fixes had only partially tamed.
Context
The deploy stack added --heading: an external P loop wz = clip(0.5 * wrap_to_pi(theta0 - theta), +/-0.6), recomputed each frame and fed into the policy's ordinary wz command slot. Measured: net yaw walk_v6 60.3 -> 5.8 deg, walk_v5 17.4 -> 4.2 deg. A run-level audit later corrected the mechanism story: training had heading_command=False since v1 - the policy had NEVER seen heading-error feedback, so the loop works purely because its output lands inside the trained command distribution wz ~ U(+/-0.6): "收益真实,当时的机理解释写错了" (the benefit is real; the mechanism explanation had been wrong). v8 then closed the loop properly: training-side heading command enabled with rel_heading_envs=0.5 - half the envs get heading-error-driven wz, half get explicit constant wz, because deployment feeds wz BOTH ways (straight-line = heading feedback, turning = constant command) and rel=1.0 would have made constant-wz turning out-of-distribution. The law, gain, and clip were aligned item-by-item between trainer and deploy tool.
Change
Deploy-side outer loop first (no retrain needed); then v8-D enabled the matching training-side heading command at rel=0.5 with identical gain (0.5) and clip (+/-0.6), contract unchanged (wz slot carries the computed value).
Outcome
Drift handled at deploy (5.8 deg) generations before training caught up; the alignment removed the residual train/deploy distribution mismatch, with the accepted cost booked (open-loop straight walking becomes more OOD for heading-envs - irrelevant since acceptance and deployment always run the loop).
Mechanism
A learned velocity-tracking policy is a valid inner loop for any outer controller whose commands stay within the trained command distribution - the policy needs no knowledge of the outer objective. Full alignment then requires training on the same mixture of command sources the deployment actually uses, in the observed proportions.
Applies when
- heading/position drift on a velocity-tracking policy
- designing outer loops over learned locomotion controllers
- training command distribution differs from how deployment feeds commands
“审计更正(2026-08-02,run 级 env.yaml):训练侧自 v1 复盘起就是 heading_command=False … 策略从未见过航向误差反馈。--heading 是评估/部署侧外加的航向 P 环(wz=clip(0.5·err,±0.6), 落在训练分布 wz~U(±0.6) 内)。实测净偏航 walk_v6 60.3° → 5.8° … 收益真实,当时的机理解释写错了”
train/WALK_V7_SPEC.md § 0. 本轮之前已经改掉 (航向闭环, 含审计更正) The real robot's right-leg kicking was over-trained-delay times loop gain - irreducible pipeline latency is plant, model it fully from day one
pipeline-latency-is-plant-not-drMeasure the end-to-end action pipeline delay and build it into the nominal plant and every acceptance gate from day one; treat power/scale deratings that "fix" oscillation as gain-reduction crutches flagging an unmodeled delay, and expect higher-feedback-gain policies to be MORE delay-fragile.
Symptom
On hardware, s1c/s1d at action scale 1.0 always kicked wildly with the right leg (s1c only ran as SOTA at power 0.8; s1d only at 0.7) - while sim showed nothing under default evaluation.
Context
Sim reproduced the incident item by item once the real pipeline delay was injected: s1d@1.0 with --delay 1 fell at 10.2 s, --delay 2 at 5.2 s; s1c@1.0 stressed (r_hip_roll saturation 5 -> 16%; "右脚" = the policy's chirality makes the right leg its high-gain leg); and the combos that worked on hardware (s1c@0.8+delay2, s1d@0.7+delay2) all survived in sim. Mechanism: the real pipeline is ~1-2 ticks (BusWorker next-cycle pickup + CAN round trip) but S1.1 trained only to 1 tick - "超训延迟 × 全环路增益 = 振荡;衰减 = 压环路增益换稳定" (delay beyond training x full loop gain = oscillation; the power derating had been buying stability by compressing loop gain). s1d was MORE fragile than s1c because its yaw 3-layer stack had learned higher feedback gain - higher gain, lower delay tolerance. Three changes: latency DR widened to cover reality; acceptance gates and smoke runs moved permanently to --delay 2 ("门必须在真机条件下预测 真机"); and the doctrine written twice-paid: "不可约的管线属性(延迟、 限速)不是'随机化选项',是 plant 本体,第一天就该全额建模" - S1's nominal-then-robust staging falsified by hardware for the second time. The later s1e hardware run at power 1.0 (no kicking, normal force) closed the loop: "0.8 = 旧代拐杖" - the derating had been a crutch for the under-modeled delay, not a real requirement.
Change
Latency modeled as plant from day one of any lineage (measured 1-2 ticks covered, bridge-layer rate limits likewise modeled by default); every gate and smoke evaluation issued under --delay 2.
Outcome
Kicking reproduced, explained, and eliminated in the s1e generation at full scale and full power; the deploy-side crutches (0.7/0.8) retired for the new lineage.
Mechanism
Feedback oscillation onset is a product of loop gain and phase lag; a policy trained below the real delay learns gains that sit past the real stability margin, and any output derating masks it by scaling gain down. Since pipeline delay is deterministic hardware property - not an uncertainty - it belongs in the nominal plant, and every evaluation must include it or the gate predicts a robot that does not exist.
Applies when
- hardware oscillation/kicking that sim only reproduces with added delay
- a policy only runs on hardware at reduced power/scale
- defining what belongs in the nominal plant vs the DR list
“真实链路延迟 ~1~2 拍 … S1.1 只训到 1 拍——超训延迟 × 全环路增益 = 振荡;衰减 = 压环路增益换稳定。s1d 比 s1c 更脆 = yaw 三层栈学出更高反馈增益,增益越高延迟容忍越低。… 教训入账:S1「先标称后鲁棒」第二次被真机证伪——不可约的管线属性(延迟、限速)不是"随机化选项",是 plant 本体,第一天就该全额建模。”
train/OMNI_V0_SPEC.md § 3. S1.4(真机右脚乱踢事故强制) Cross-simulator gate (Isaac Lab to MuJoCo) comes before any hardware attempt
sim2sim-gate-before-sim2realGate every policy through a second simulator with an independently built plant before hardware; treat sim2sim failure as a contract or overfitting bug, and sim2real failure after a sim2sim pass as a plant/actuator gap.
Symptom
A policy that only ever ran in its training simulator carries untested dependencies on that simulator's solver, contact model, and defaults; the first place those dependencies surface should not be the real robot.
Context
Standing order of operations for the whole Lucen program, recorded as the opening line of the experience log: train in Isaac Lab, gate in MuJoCo, only then go to hardware. The MuJoCo side is the same plant used for evaluation batteries, so a sim2sim pass also validates the exported policy + contract (obs ordering, scales, defaults) outside the training stack.
Change
Pipeline rule adopted - every checkpoint must pass the MuJoCo evaluation battery (sim2sim) before it is considered for real deployment (sim2real).
Outcome
Used generation after generation as the cheap filter; hardware sessions only ever received policies that had already survived a second simulator.
Mechanism
Two simulators disagree exactly where a policy is overfit to simulator-specific artifacts (contact softness, integrator, default parameters, obs conventions); a cross-sim transfer catches contract bugs and solver overfitting at zero hardware risk, so real-robot failures that remain are attributable to genuine plant/actuator gaps.
Applies when
- planning the path from training to first hardware trial
- exported policy behaves differently outside the training framework
- triaging whether a real-robot failure is contract vs plant
“先sim2sim - 从isaaclab 到mujoco / 再sim2real”
Experience.md § opening lines (1-2) Knee swing collapsed because it directly trades against the slip penalty - price the conflict explicitly and clamp what reward cannot hold
knee-swing-vs-slip-pricingWhen a behavior collapses as another metric improves, look for the term pair trading them and set their price ratio deliberately (with escalation and reverse tripwires pre-registered); where the policy actively spends action budget to undo your target, stop paying more reward and clamp the target space structurally.
Symptom
Knee peak-to-peak swing collapsed across generations - v5 33 deg, v10 26-30, v10b 7-8, v11 6.5-8.6 - and rolling the clock back did not recover it, acquitting the clock; the collapse tracked the gated slip penalty instead: "屈膝与不打滑在当前奖励里直接对抗" - v10b's excellent 93 deg slip was purchased with knee amplitude.
Context
Reward-side flexion fixes had failed three times: raising reference amplitude backfired twice (v9/v11), and v11's deep-squat default was actively fought by the policy - it spent 0.68 of action budget pulling the squat straight ("被策略花 0.68 动作拉直反杀"). v12's design accepted the conflict as real and attacked on two tracks: (1) ECONOMICS - a direct knee_swing_amplitude reward (+0.3, target 0.55 rad, capped at 0.6/step = 55% of tracking), explicitly opposed to the slip penalty by design ("显式对立——这正是设计:v12 就是这场对抗的定价实验"), with an escalation ladder (K +0.3 -> +0.5, then slip -0.5 -> -0.3, one layer at a time) and a reverse tripwire (slip telemetry back at v10 levels -> slip weight to -0.8, accept ~20 deg knee compromise); (2) STRUCTURE - knee target bounds [0.2, 0.9] rad so full straightening is physically impossible (straightest 11.5 deg) and the 0.68 fighting budget is released. A bonus falsifiable prediction was attached: phase-lock strength tracks amplitude (v9_probe 48 deg locked 2.5 Hz; v11 low-amplitude 1.36 Hz unlocked), so if K works, hardware phase-lock should return - one change, two verdicts.
Change
knee_swing_amplitude reward + knee target clamp + pre-registered escalation/reverse levers; the failed reward-side-only approach retired.
Outcome
The lineage was frozen before v12 trained (strategic reset), but the diagnosis stands as the walk line's clearest example of two reward terms trading a behavior between them, with the pricing experiment and structural clamp fully designed and calibrated.
Mechanism
When two terms price opposite aspects of one motion (swing amplitude creates yaw momentum that becomes slip), the optimizer settles wherever the price ratio puts it - patching one side moves the equilibrium, not the conflict. Explicit pricing makes the trade a designed quantity; structural clamps remove the regions where the policy spends budget fighting the designer.
Conflicts
The pricing experiment (K vs slip) was designed and calibrated but never trained - the 2026-08-05 reset suspended v12; the collapse attribution table and the 0.68-action counterattack are measured, the remedy's效果 is untested.
Applies when
- one gait quality degrades in lockstep with another's improvement
- the policy visibly fights a default pose or reference
- repeated reward-side fixes for the same behavior have failed
“膝摆塌在 v10→v10b,头号嫌疑是门控滑移罚(四代实测膝 p2p:v5 33° / v10 26~30° / v10b 7~8° / v11 6.5~8.6°;退时钟没救回 → 非时钟)——"屈膝"与"不打滑"在当前奖励里直接对抗 … 奖励侧修屈膝已三败 … v11 深蹲 default 被策略花 0.68 动作拉直反杀”
train/WALK_V12_SPEC.md § 0. 定位 / 2. K —— 膝摆经济(与滑移罚的对偶) A sim veto needs real confirmation too - the worst sim cell was scheduled as the most informative hardware run
sim-veto-needs-real-confirmationNever let sim alone both condemn a purpose-built configuration and escape audit: spend one cheap, safeguarded hardware run on the condemned cell, pre-registering what agreement and disagreement would each imply about the proxy.
Symptom
The fric-2400@kd1.0 combination was sim's worst cell across the board (survival 17/20 - the only miss, mu0.4 1/20, push 103/160, zero-cmd 2/20), yet it was the only product specifically trained for the kd1.0 deployment gain - discarding it on sim evidence alone would leave the sim's own validity untested exactly where it mattered.
Context
The team had been burned in the other direction before ("Isaac 指标三次 零预警" - training-side metrics gave zero warning three times), so the symmetric rule was written: sim's rejection also needs hardware confirmation ("sim 判被支配 ≠ 真机被支配 … sim 的否决也要真机确认"). The run was pre-registered with a dual reading: real matches sim -> the S2f ladder closes and the fork root is settled; real clearly better than sim -> the MuJoCo proxy has a systematic bias in the kd1.0/low-margin region, "那比选型本身重要得多" - and every S2f sim acceptance would need re-scoring.
Change
The condemned configuration was kept on the hardware roster (last, spotted, minimal exposure) explicitly as a proxy-validation probe, not as a deployment candidate.
Outcome
Session design captured either result as progress: selection confirmed, or a proxy bias discovered that would re-price the whole ladder's verdicts.
Mechanism
Every sim verdict is a joint statement about the policy AND the proxy; cells where a policy was purpose-trained for the exact condition sim condemns are where proxy error is most likely and most costly. Testing the veto converts a selection decision into a calibration measurement of the evaluator itself.
Applies when
- sim rejects the configuration that targets the actual deployment condition
- the eval proxy's calibration has never been checked in that regime
- deciding which hardware runs are worth their risk
“但它也是唯一为 kd1.0 部署档专门训的产物 —— sim 判被支配 ≠ 真机被支配, 「Isaac 指标三次零预警」的教训反过来同样成立: sim 的否决也要真机确认。… 若真机明显好于 sim → MuJoCo 代理在 kd1.0/低裕度区有系统性偏差, 那比选型本身重要得多。”
train/REAL_RUN_S2.md § 上机名单 note / 2. sim 侧预注册预期 ⑤ The smoke watcher panicked at the wrong operating point and its score goes blind when gates saturate - treat it as a survival sentinel, not a judge
smoke-watcher-operating-pointConfigure every automated evaluator at the lineage's declared deployment operating point, give it graded metrics that cannot saturate, and until then scope its authority to catastrophe-detection - never let a mis-configured watcher stop or rank a rung on its own.
Symptom
Two watcher misfires in one ladder: (1) during the friction rung the watcher (evaluating at kd 1.0) reported panic-level 1/3 survival from iter 3300 - falsified by the official kd 1.2 scan, because the lineage's design operating point was kd 1.2 and the watcher lacked the --kd-scale passthrough; (2) during the PD rung the watcher's early-stop score froze at iter 1050 despite ongoing drift improvements, because with all eight gates passing (constant 0/3 failures) the score has no gradient left - "八门全过恒 0/3 时 score 对漂移改善盲, s1f 课文三现".
Context
Both are the same category: the in-training smoke loop is an instrument with its own configuration (operating point, score design), and its verdicts are only as aligned as that configuration. The booked doctrine: "冒烟只当存活哨兵" - until the watcher evaluates at the deployment operating point with graded metrics, its role is detecting catastrophes, not ranking checkpoints; ranking belongs to the full battery at the design operating point (and the watcher's scoring was separately patched to weight survival 3x so recoveries during hard phases are not early-stopped away).
Change
Watcher debt booked (--kd-scale passthrough); score saturation acknowledged with graded columns planned; selection authority kept with 20-seed batteries at the declared operating point.
Outcome
A false panic did not abort a rung that was actually passing at its design point; a frozen score did not hide real drift gains; the instrument's authority was scoped to what its configuration can actually see.
Mechanism
An evaluator is itself configured (gain profile, delay, metrics); evaluating a policy away from its design operating point measures a counterfactual robot, and bounded scores saturate once binary gates pass, losing all sensitivity. Instruments need the same operating-point discipline as deployments and graded outputs to retain gradient.
Applies when
- an automated smoke loop contradicts the official battery
- early-stop scores freeze while graded metrics still improve
- lineages with non-default deployment gain/delay profiles
“watcher (kd1.0 口径) 3300 起 1/3 恐慌被 kd1.2 正式扫描证伪为考纲外假象 —— 工作点评测口径教训: watch_ckpt 缺 --kd-scale 透传 (待补), 冒烟只当存活哨兵。… watcher score 饱和误停 @1050(八门全过恒 0/3 时 score 对漂移改善盲, s1f 课文三现)”
train/README.md § omni_s2e_fric (watcher 恐慌被证伪) / omni_s2e_pd (500 臂) action_rate weight is the sim2real bandwidth knob - re-tune it whenever a rate limiter is removed
action-rate-weight-vs-bandwidthSet action_rate weight relative to real actuator bandwidth, and re-tune it any time another smoothing/limiting element (filter, slew limiter, gain) changes - reward weights are load-bearing parts of the actuator model.
Symptom
With a low action_rate_l2 weight the policy learns fast actions; the unmodeled part of the actuator response is then excited hardest, and sim2real "直接崩" (collapses outright). With too high a weight, actions become so slow the robot cannot maintain balance.
Context
The reference developer called action_rate_l2 the single most important reward for transfer, with side-by-side video evidence that the high-penalty, slower policy is clearly better on hardware. Lucen context: the team had just removed the SOFT_SPD=1.0 velocity limiter, which had been an implicit actuator-bandwidth constraint - leaving action_rate as the only remaining constraint on action speed.
Change
Decision recorded: after removing SOFT_SPD, re-evaluate the action_rate weight rather than keep the old value, since its effective role changed from "additional smoother" to "sole bandwidth constraint".
Outcome
Logged as a priority follow-up ("重新评估 action_rate 权重 - 拆掉 SOFT_SPD 之后这一项的作用变了"); the failure mode it guards against is training high-frequency actions the real actuators cannot track.
Mechanism
Slower actions stay inside the frequency band where the ideal-PD sim actuator and the real actuator agree; fast actions probe the band where unmodeled delay, inductance, and bandwidth limits dominate, so model error is amplified in exact proportion to action speed. Any removed external rate limit transfers that constraint's entire job onto the action_rate penalty.
Conflicts
The low/high tradeoff evidence is the external developer's report (with video); the Lucen-side entry is a pre-registered risk and decision, not yet an on-robot A/B at the time of writing.
Applies when
- removing or adding an action filter, slew limiter, or low-level speed cap
- real robot shows high-frequency chatter or overheating absent in sim
- tuning smoothness rewards before a hardware deployment
“权重低 → 动作快 → 执行器模型不准的部分被放大,sim2real 直接崩 / 权重高 → 动作慢 → 好迁移,但可能慢到无法维持平衡 … 我们刚拆掉 SOFT_SPD=1.0 的限速器,等于把执行器带宽约束整个移除了。action_rate 惩罚现在是唯一还在约束动作速率的东西,需要重新评估权重”
Experience.md § action_rate_l2 是他认为最关键的 reward (lines 61-70) Anchoring the action on the measured joint angle (target = q + beta*a), with a beta curriculum down to tau_limit/kp, bounded torque by construction, removed the re-falls and later stood the robot up on hardware
beta-anchored-action-targetFor large-motion skills on position-controlled actuators, bound the action relative to the measured joint angle with a per-joint authority of tau_limit/kp, curriculum the authority down from full range, keep the curriculum state out of the observation and pin acceptance at the deployed authority - and make the deployment code refuse to run the anchored contract without a measured q.
Symptom
The V0 full-range absolute action produced violent targets; the V1 command-anchored rate limit made standing oscillate. Both failure modes came from how the action becomes a target.
Context
V2.0 (user approved, from scratch): BetaAnchorJointPositionAction, target = q_measured + beta_j(m)*a, memoryless per step. beta_j(m) = floor + m*(beta0 - floor), beta0 = the contract half-range (m = 1 reproduces V0 authority), floor = min(tau_limit/kp, beta0): hip_pitch 1.309 -> 0.40, knee 1.047 -> 0.40, hip_yaw -> 0.917, the other joints unchanged - the tightening lands exactly on the joints the V0 torque account convicted. m drops 0.1 per step when a standing-share EMA exceeds 0.35. beta is NOT in the observation, so the 45-dim contract is untouched; acceptance is pinned at m = 0 because the Python curriculum state is not saved in the checkpoint. The deployment chain got a new profile (recovery_v2: action_anchor current_q, explicit per-joint beta written into the contract, independent of the gain profile), and policy_io raises if q is missing rather than silently falling back to the absolute contract; the old profile's check reproduced its pre-change deviation bit for bit.
Change
New action term and beta curriculum; later the RS06 floor was lowered 0.40 -> 0.30 -> 0.25 (kp*beta 7.5 N*m) and the stamped deployment profile was synced to 0.25.
Outcome
First acceptance at m = 0 (v2_0b): re-falls 0% in every category, the torque gate passed for the first time on the line (worst 69.9%), knee jitter 0.004; supine 98.8 / side 88.8% with prone and mid still failing (fixed by the conditional pull curriculum). MuJoCo showed demand at or under the limits (hip_pitch 11.7/12 against V0's 26.8). Lowering beta cut impact (hip_pitch demand 9.7 -> 8.5 N*m) but barely slowed the get-up - it had become coordination-limited. Enabling the policy moves the target only +/-beta around the current pose, so there is no homing fling; the 08-11 real get-up and the later v3_1p1c both run on this contract.
Mechanism
kp*beta caps the proportional torque in a single step with no build-up delay and no memory, giving both a hard impact bound and full balance bandwidth.
Applies when
- a skill needs full joint range but hardware torque limits are low
- absolute position targets cause impacts or saturation
- changing the action semantics of a contract that deployed policies share
“**动作项** `BetaAnchorJointPositionAction`:`target = q_实测 + β_j(m)·a`, 逐步无记忆 … **Play/验收钉 m=0(= floor = 部署档)**:python 课程状态不进 checkpoint, Play cfg 显式 `beta_m_start=0` … 判读:**结构赌注兑现** —— 站姿零再摔 + 力矩账首过(kp·β 封顶按构造)”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §33 V2.0 预注册(2026-08-10,用户点头开工):β 锚定动作空间,从零训 PPO's Gaussian noise cannot compose phase-locked oscillations - deliver them as feed-forward and let the policy learn the residual
feedforward-for-phase-locked-skillsIf a skill needs a temporally coherent (phase-locked) action component, do not expect step-wise exploration to find it: inject a verified feed-forward and train the policy as a residual stabilizer, keeping the feed-forward inside the deployment contract.
Symptom
Four different reward arrangements (no reference / wrong-sign reference / correct-sign reference / cage released) all failed to elicit sidewalk, while open-loop probes proved the behavior existed and was safe on the same platform with the same policy as base.
Context
Producing lateral velocity requires a phase-locked hip_roll oscillation synchronized to the gait clock. PPO's exploration is per-step, zero-mean, uncorrelated Gaussian noise - it can never compose a sustained phase-locked component, so the behavior is unreachable by exploration regardless of how it is rewarded. The fix changed the delivery channel: target = default + scale*action + lat_ff(cmd_vy, phi). The policy's action becomes a residual on top of the feed-forward, retaining full balance authority (it can even cancel the feed-forward); the feed-forward supplies exactly the component exploration cannot. This mirrors why the sagittal joint_pos_ref worked (it also delivered phase structure), just via a different channel.
Change
Contract-level change, done cleanly: new profile omni_ff (= omni + lat_ff_gain -0.5), existing omni profile bit-identical; feed-forward applied after the action delay stage; missing cmd/phase raises instead of silently dropping; deployment must use the same phi as build_obs (recomputing gives a one-tick phase misalignment).
Outcome
From C2-700, +100 iterations sufficed: product omni_c4_ff800 scored vy +120%/+125% (from +4%/-1%), 260/260 cells at 20/20 survival, zero old-skill regression, left/right gap 5 pp - the entire C4 saga resolved by changing the delivery mechanism, not the reward.
Mechanism
Exploration noise spans only the subspace its correlation structure can express; skills requiring coherent oscillation lie outside the span of i.i.d. per-step noise. Feed-forward moves the required structure into the action pipeline where it needs zero probability mass to appear, reducing the learning problem to stabilizing around a demonstrated behavior - which PPO does well.
Applies when
- a periodic/oscillatory skill trains flat under every reward variant
- open-loop injection of the behavior already works
- considering GRU/curriculum/exploration tricks for a rhythmic skill
“病因不在奖励,在探索形式:产生侧向速度需要相位锁定的 hip_roll 振荡,PPO 的逐步高斯噪声零均值无相关,合不出相位锁定分量。… target = default + scale·a + lat_ff(cmd_vy, φ)。策略动作因此是前馈之上的残差,保留全部平衡权限”
train/C_LADDER_RUN.md § 3j. C4-redo4:唯一变量 = 侧步参考改为前馈注入(契约级) Audit rewards by realized contribution (weight x achieved value) - a weight of 2.0 was really paying 0.04
realized-contribution-auditEvaluate a reward table by each term's realized per-step contribution under the current policy, never by its weight column; if a term's realized value is ~0, escalating its weight is a no-op - change the term's structure instead.
Symptom
Foot dragging persisted through repeated weight escalation: feet_air_time had been raised 0.25 -> 1.0 -> 2.0 across versions with no behavioral change, and the training-side comment even recorded the fact ("几乎没有 单支撑相, 是拖着脚蹭") without the fix changing form.
Context
Computing realized per-term contributions in the trained state exposed the economy: feet_air_time contributed weight 2.0 x achieved 0.019 = 0.038 per step, against tracking's +1.20 - lifting the leg earned 3% of what tracking earned, so dragging was the rational optimum no matter the weight escalation. The same table acquitted the energy penalties (total -0.30 negative vs +1.74 positive) that a naive read of weights (-5.0 orientation!) would have blamed.
Change
Fix redirected from "raise the weight again" to "add a term whose realized contribution changes the optimum": a clearance penalty sized so its realized magnitude (~0.018/foot when dragging) is comparable to feet_air_time's, enough to flip the optimum without drowning tracking.
Outcome
With the term economy corrected (plus posture/range fixes), swing height reached 34 mm and tracking 87% by v6; weight escalation of the old term was abandoned.
Mechanism
A reward weight is only a multiplier on whatever the policy currently achieves on that term; when the achieved value is near zero (behavior absent), escalating the weight multiplies near-zero. Optimizer behavior is governed by realized per-step magnitudes, so audits must be conducted in that currency.
Applies when
- a behavior persists despite repeated weight increases
- auditing whether penalties are "too strong" or rewards "too weak"
- sizing a new reward term against existing ones
“把 feet_air_time 权重从 0.25 → 1.0 → 2.0 一路加,但没有加高度项。量级算下来:feet_air_time 权重 2.0 × 实得 0.019 = 0.038,而跟踪奖励是 1.2。抬腿的边际收益只有跟踪的 3%,拖地当然是最优解。… 正项 +1.74,负项 −0.30。能量惩罚不是瓶颈,抬腿没收益才是。”
train/WALK_DIAGNOSIS.md § 决定性证据(#1) / 各项奖励的实际量级