Skip to content

Training Coach

The coach reads a training run and returns a diagnosis, in-whitelist proposals and an experiment plan — and every claim cites one of the cards below. This is that corpus: 22 methodology rules distilled from a real sim2real programme, and 171 episode cards behind them, each with the sentence in the war history it came from.

Doctrine

A report may cite any of these as doctrine-N.

  1. doctrine-1Contract freeze and fingerprint discipline

    The policy I/O contract (observation layout, scales, history semantics, action pipeline) is frozen and fingerprinted; every exported policy is stamped and verified; contract changes ship as new versioned profiles that leave old artifacts bit-identical, and old policies run forever under their era's pinned profile.

    Case. The 215-dim omni contract was frozen with a three-machine digest; the one contract-level extension (lateral feed-forward) went in as a new `omni_ff` profile with the old profile provably untouched, and the contract checker caught two real wiring bugs before any training (`contract-freeze-and-checker`). A silently changed gait-clock default would have fed old policies a 25% slower clock - closed by pinned legacy profiles (`legacy-profile-pinning`). A stale derived USD forked plant mass 2.2% until an automated source-vs-derived instrument gated it (`derived-asset-staleness-check`). A gain profile is part of the closed loop a policy was trained in and belongs in its stamp; the recovery line's anchored authority was left out of its manifest and recorded as the gap not to repeat (`gain-profile-belongs-in-the-stamp`), and a second policy behind a deploy-side switch made the handoff state itself a contract (`recovery-two-policies-and-a-state-machine`, `walk-recovery-fsm-handoff`).

    Coach application. On any proposal touching obs/action semantics, defaults, or derived assets: demand the version/profile plan, the fingerprint update, and the checker extension in the same change; flag any old artifact that would run under new defaults.

    contract-freeze-and-checkerlegacy-profile-pinningderived-asset-staleness-checkgain-profile-belongs-in-the-stamprecovery-two-policies-and-a-state-machinewalk-recovery-fsm-handoff

  2. doctrine-2Attribution by resolved training params - never eval-override knobs

    Capability differences between lineages are explained only by digging each lineage's *resolved* training configuration and eliminating columns; evaluation-side override knobs (kd-scale, power-scale, cycle-time) act on the plant for *every* policy and may serve as deployment mitigations but never as explanations.

    Case. Low-friction robustness across 8 lineages x 3840 cells was traced to kd DR *bandwidth* - every lineage had ground friction pinned to (1.0,1.0), so "trained friction" could not be the axis; the parameter axis and the plant axis were explicitly separated after the first attribution conflated them (`kd-bandwidth-mu-law-attribution`). "Weak turning" on hardware was a power-scale plant effect, not a training gap (`deploy-knob-attribution-before-retraining`); slowing the deploy clock was out-of-distribution, not a feature (`cycle-time-override-is-ood`). The ground truth for what a run trained under is the logged per-run config, not the source tree (`resolved-config-is-source-of-truth`).

    Coach application. Whenever asked "why is lineage A better", require the resolved-param table first; kill zero-variance columns; refuse explanations phrased in eval-knob terms; when a knob helps, label it deployment mitigation.

    kd-bandwidth-mu-law-attributiondeploy-knob-attribution-before-retrainingcycle-time-override-is-oodresolved-config-is-source-of-truth

  3. doctrine-3PASS gates become constraints; FAIL gates become objectives

    Once a skill passes its gate, that gate converts into a standing regression constraint (budget <= 2/20 against the parent baseline) for all later training; gates currently failing are the only legitimate objectives of the next rung.

    Case. The C ladder ran one frozen 13-cell x 20-seed matrix at every rung with promotion = "new skill PASS and old skills within regression budget"; C1 was stopped and re-rooted precisely because it trained away the root's backward PASS (`fixed-acceptance-matrix-per-rung`, `preregistered-stop-criteria-per-rung`). The C4 product shipped only at 260/260 cells with zero regression.

    Coach application. Keep the ledger: every PASS adds a constraint row; propose rungs only against FAIL rows; treat any constraint violation as stop-and-attribute, never "the next rung might win it back".

    fixed-acceptance-matrix-per-rungpreregistered-stop-criteria-per-rung

  4. doctrine-4One variable per ladder rung - counted against what the checkpoint saw

    A rung changes one variable, where "one" is counted against the checkpoint's actual training state, not against the current config's diff; batching is allowed only when each change owns a disjoint symptom space with a pre-registered ablation order.

    Case. Two rungs failed identically because resuming s1e-500 under the evolved config silently added four plant variables the checkpoint had never seen ("单变量纪律不只看「我改了什么」,还要看「checkpoint 见过什么」" - `resume-state-dr-audit`). v8 legally batched four orthogonal fixes with a written ablation order (`orthogonal-batch-with-ablation-order`); v9 spent one run completing a 2x2 factorial so either outcome convicted a factor (`fill-the-missing-factorial-cell`); v10b's three-way ablation wrongfully convicted the clock and had to be retried fairly.

    Coach application. Before any resume: diff cfg against the checkpoint's logged training state. Before any batch: require the symptom-ownership map and ablation order in writing.

    resume-state-dr-auditorthogonal-batch-with-ablation-orderfill-the-missing-factorial-cell

  5. doctrine-5Pre-register risks, readings, and stop criteria before the ladder

    Before a ladder or risky rung, write down the known risks, the interpretation of every plausible outcome, and hit-any-one stop criteria - frozen before training, tightened when priors say results should come fast.

    Case. The C ladder opened with three numbered risks including the exact falsification condition for its own root choice; A/B arms carried "预注册读法(事后不改)" tables; a level expected to fail was run anyway for its pre-registered diagnostic value (`preregister-risks-and-fork-readings`). Stop criteria caught C4-redo rungs at +200 instead of full caps (`preregistered-stop-criteria-per-rung`); hardware sessions pre-registered per-config expected signatures and the disagreement rule "不改结论改账" (`preregistered-real-expectations`, `feasibility-accounts-lock-design-point`).

    Coach application. Refuse to open a rung without the written risk/reading/ stop block; after results, read conclusions off the pre-registered table and flag any post-hoc reinterpretation.

    preregister-risks-and-fork-readingspreregistered-stop-criteria-per-rungpreregistered-real-expectationsfeasibility-accounts-lock-design-point

  6. doctrine-6Plant parameters are measured, never invented

    Every plant number carries measurement provenance: armature = N^2 x rotor inertia from no-load tests, friction split by rig and by API column, torque limits shaped by per-joint gait peaks, latency traced through the real pipeline, masses weighed - and DR bands are additive around the measured nominal, sized to the measured dispersion.

    Case. Guessed friction was 2.5x low and guessed damping 5x high (`friction-measured-not-guessed`); armature had been 0 with a 9:1 gearbox (81x reflected inertia, `armature-n2-rotor-inertia`); a uniform torque derating was "the wrong shape" vs measured peaks (`torque-limit-shape-by-measured-peaks`); the delay implementation itself was a wrong plant for a whole lineage (`latency-lerp-reverse-extrapolation`); the run design point was locked by three accounts including the tau_limit/kd speed ceiling (`feasibility-accounts-lock-design-point`); identified friction had to land in the right simulator API columns to act at all (`sim-api-friction-columns`). The recovery and one-leg lines opened with the same kind of accounts before any reward existed - a connected static path and the torque along it for an armless get-up, and the gains single support needs to be holdable at all (`get-up-feasibility-accounts-before-training`, `single-support-gain-authority-probe`).

    Coach application. For any plant value in a config review, ask "measured how?"; reject absolute ranges with no nominal; check API column mapping and derived-asset regeneration whenever measured values land.

    friction-measured-not-guessedarmature-n2-rotor-inertiatorque-limit-shape-by-measured-peakslatency-lerp-reverse-extrapolationfeasibility-accounts-lock-design-pointsim-api-friction-columnsget-up-feasibility-accounts-before-trainingsingle-support-gain-authority-probe

  7. doctrine-7Sim2sim gate before sim2real - under deployment conditions

    Every checkpoint passes a second, independently built simulator before hardware, and both the gate and the smoke loop run under the measured deployment conditions (real pipeline delay, honest contact parameters, the deployment gain/power profile).

    Case. The standing order "先sim2sim 再sim2real" (`sim2sim-gate-before-sim2real`); acceptance flipped to match hardware only under measured condim/torsional friction (`eval-plant-honesty-contact-params`); gates moved permanently to `--delay 2` after the kicking incident (`pipeline-latency-is-plant-not-dr`); and the harness itself must be audited - a frame-convention bug in the cross-sim evaluator invalidated a whole line of verdicts (`body-frame-velocity-api-audit`). The recovery line's second simulator caught a torque penalty paid for by bracing the legs together (`torque-penalty-bought-by-leg-bracing`), and a 1.8x torque disagreement between the two plants stayed binding because its one surviving explanation was never tested (`torque-disagreement-between-simulators-unresolved`).

    Coach application. Block any hardware request lacking a second-sim PASS at deployment conditions; when sim2sim and training-side metrics disagree, treat the evaluator as a suspect too.

    sim2sim-gate-before-sim2realeval-plant-honesty-contact-paramspipeline-latency-is-plant-not-drbody-frame-velocity-api-audittorque-penalty-bought-by-leg-bracingtorque-disagreement-between-simulators-unresolved

  8. doctrine-8Observation honesty - the actor's inputs are a hardware contract

    The actor observes only signals the real robot produces with realistic noise; privileged truths go to the critic; history windows are estimators and must train under plant variation; rewards on quantities the actor cannot observe buy only average suppression, never closed-loop correction.

    Case. Ground-truth velocity/forces went critic-only (`observation-honesty-critic-only`); frame_hist under zero DR memorized the trainer's plant fingerprint - 0/20 transfer (`history-obs-needs-plant-variation`); world-frame yaw rewards could not teach pull-back because heading is unobservable to the actor - correction was routed to the deploy outer loop instead of breaking the contract (`reward-observability-limit`, `deploy-heading-loop-and-align-training`).

    Coach application. Audit every actor-obs element for hardware existence; require minimal plant jitter whenever history/recurrence exists; for each reward, ask "can the actor see this error?" and route correction tasks to outer loops.

    observation-honesty-critic-onlyhistory-obs-needs-plant-variationreward-observability-limitdeploy-heading-loop-and-align-training

  9. doctrine-9Reward economics are audited in realized currency

    Reward design decisions are made on realized per-step magnitudes under the actual policy and command distribution: price the do-nothing optimum before adding a mode, compare achieved values to the computed ignore-floor, calibrate thresholds between measured healthy and sick distributions, and ship every new penalty with a withdrawal clause.

    Case. feet_air_time at weight 2.0 realized 0.038 vs tracking 1.2 - drag was rational (`realized-contribution-audit`); ignoring a vy command cost 28-180x less than ignoring vx until a gated tracking term was added (`reward-cost-of-ignoring-audit`, `gate-new-reward-terms-by-command`); achieved-vs-floor separated "never learned" from "priced out" (`ignore-floor-diagnosis`); the foot-distance wall was placed between measured healthy (0.6% tax) and sick (55%) policies (`calibrate-threshold-between-healthy-and-sick`); the landing penalty carried a pre-registered stand-down condition and actually stood down (`calibration-threshold-with-withdrawal-clause`); two clearance terms were inert until zero-points and gate occupancy were checked (`inert-reward-term-audit`). A get-up policy sat because three gated terms paid the seated pose 84% of the return and the one term that could tell sitting from standing was an exp kernel reading 4.6e-5 at the real error (`seated-basin-dead-exp-kernel`); a torque-tail term was weighted by its measured steady value beside a peer term after the estimate proved 12x off (`tail-torque-needs-hinge-on-computed-demand`).

    Coach application. Never discuss weights in the abstract: demand the realized-contribution table, the ignore-floor number, and the healthy-pay calibration before any reward edit is approved.

    realized-contribution-auditreward-cost-of-ignoring-auditgate-new-reward-terms-by-commandignore-floor-diagnosiscalibrate-threshold-between-healthy-and-sickcalibration-threshold-with-withdrawal-clauseinert-reward-term-auditseated-basin-dead-exp-kerneltail-torque-needs-hinge-on-computed-demand

  10. doctrine-10The zero-cost option must be the desired behavior

    For every penalty, name what the zero-cost option is; penalize failure events (slip, saturation excess, contact in flight windows), never the motion or joints that healthy behavior uses; make degenerate strategies fatal via termination where penalties cannot price them out.

    Case. Joint-usage penalties for drift taxed a 1.4%-of-momentum channel 2.7/step and collapsed training; the slip penalty costs a non-slipping gait exactly zero (`penalize-the-slip-not-the-joint`). A frozen-at-clamp joint pays zero action-rate forever - only a pre-clip saturation penalty flips the cheat economics (`saturation-cheating-zero-rate-cost`). Ungated phase shaping made standing 42x more expensive than stepping and cooked the hip motors (`moving-gate-42x-stand-tax`); crouch-shuffling lived until a height termination deleted it (`termination-closes-degenerate-basin`). A gated penalty is an exit: the policy parked just outside an uprightness gate, then just under a height gate, to stop paying a stance tax, and only a positive band plus an always-on guard closed both (`penalty-gate-is-an-escape-hatch`); a soft-limit penalty that charged the standing pose itself bought a 4.1 deg lean (`soft-limit-penalty-charges-nominal-pose`); an unpriced foot attitude was spent on edge-standing (`unpriced-foot-attitude-is-a-free-variable`); and the one-leg line listed its cheapest cheats before training and still met one through a zero-gradient band (`enumerate-cheapest-cheats-before-training`, `binary-band-reward-fake-touchdown`).

    Coach application. Run the "零代价的选项是什么" audit on every proposed term; convert motion taxes into event-conditional penalties; check the termination set against each known degenerate strategy.

    penalize-the-slip-not-the-jointsaturation-cheating-zero-rate-costmoving-gate-42x-stand-taxtermination-closes-degenerate-basinpenalty-gate-is-an-escape-hatchsoft-limit-penalty-charges-nominal-poseunpriced-foot-attitude-is-a-free-variableenumerate-cheapest-cheats-before-trainingbinary-band-reward-fake-touchdown

  11. doctrine-11Measurement discipline: independent referees, signs, distributions

    A disputed measurement is adjudicated only by an independent algorithm from raw state; directional ability requires sign-antisymmetry under command reversal; bimodal metrics are reported as mode shares (never medians, never 3 seeds); ratios are not comparable when totals change; reward values compare only within one command distribution; single chaotic events never cross machines.

    Case. The triple reversal - a good metric was "refuted" by a sibling metric that shared the disease (`independent-referee-for-metric-disputes`, `body-frame-velocity-api-audit`); same-signed +/- responses were bias, not turning (`same-sign-response-is-yaw-bias`); the swing median sat in a bimodal gap (`median-hides-bimodal-distribution`); "v6 is jitterier" died on absolute energies (`ratio-metrics-need-absolute-check`); yaw gain measured 15x wrong in an oscillating frame (`heading-integral-not-body-rate`); a 44% improvement evaporated under same-distribution comparison (`same-distribution-reward-comparison`); drift direction was a limit cycle (`multiseed-sign-test-for-drift`); a cross-machine push cliff was chaos (`single-impulse-recovery-is-chaotic`).

    Coach application. Before accepting any surprising number: ask for the independent recomputation, the sign pair, the distribution shape, and the comparison conditions. Retract in writing when a metric falls.

    independent-referee-for-metric-disputesbody-frame-velocity-api-auditsame-sign-response-is-yaw-biasmedian-hides-bimodal-distributionratio-metrics-need-absolute-checkheading-integral-not-body-ratesame-distribution-reward-comparisonmultiseed-sign-test-for-driftsingle-impulse-recovery-is-chaotic

  12. doctrine-12The deployment pipeline is plant

    Irreducible pipeline properties - action latency, rate limits, power/torque scaling, teleop command mappings - are part of the nominal plant, modeled from day one and reproduced in every gate; deploy-side scalings are crutches that flag unmodeled plant, and they cannot be algebraically folded into training constants.

    Case. Right-leg kicking was over-trained-delay x loop gain; power 0.8 was a gain-reduction crutch that retired when the delay was modeled (`pipeline-latency-is-plant-not-dr`); power derating damages non-forward axes first (`power-scale-hurts-nonforward-axes`); training at 0.4 scale as the "twin" of deploying 0.5 x 0.8 collapsed 0/20 (`deploy-scaling-not-training-equivalent`); one shared teleop speed sent an out-of-band lateral command and the robot clipped its own foot (`teleop-command-band-per-axis`); the latency DR range had not even covered the measured pipeline (`latency-dr-covers-measured-pipeline`). A rate limiter added at deployment only clipped a policy that kept commanding (`deploy-rate-limiter-windup`); moved into training and anchored on the last command it became an integrator in the balance loop (`slew-anchor-is-an-integrator`); anchored on the measured angle it bounded torque and kept the bandwidth (`beta-anchored-action-target`). The walking lines' safe setting, power-scale 0.8, cut the ends of the recovery policy's full-range travel and left its spikes alone; a gain inside the trained band did the job (`power-derating-cuts-full-range-contract`).

    Coach application. Demand the measured pipeline latency/limits in the plant model and in gate conditions; treat every deploy-side derating as a question ("what is this compensating?"); block per-axis command sources that exceed training bands.

    pipeline-latency-is-plant-not-drpower-scale-hurts-nonforward-axesdeploy-scaling-not-training-equivalentteleop-command-band-per-axislatency-dr-covers-measured-pipelinedeploy-rate-limiter-windupslew-anchor-is-an-integratorbeta-anchored-action-targetpower-derating-cuts-full-range-contract

  13. doctrine-13DR budget is finite; its distribution is the measured support

    Robustness is a conserved budget: disturbance training on an already-hardened lineage borrows from existing margins; DR ranges span the measured deployment support - no fictitious tails (they buy degenerate gaits), no single constants (they allow thin-margin specialization); harden the plant only after the task distribution is final.

    Case. The same push dose helped a narrow lineage and damaged a balanced one - budget conservation (`push-dr-conditional-budget-conservation`); wide latency tails bought drag-glide, constant values shipped 60% thinner tilt margins - the answer is a narrow band on the measured support (`dr-tail-plant-continuation`, `constant-value-dr-overfits-margin`); task-first ordering because hardening a soon-to-change task wastes budget (`task-shaping-before-plant-hardening`); COM randomization used deliberately as a behavior-shaping tool, and rolled back on symptom per its own contract (`com-randomization-forces-leg-spread`, `com-dr-rollback-on-symptom`). DR that is switched on can still be thin: the run policy fell in the frontal plane its gain-and-latency randomization never touched (`thin-dr-judged-by-channel-coverage`), and a friction priority settled under one action contract had to be re-measured under the next (`friction-priority-re-measured-after-plant-change`).

    Coach application. Before any DR rung: check the untrained policy against the spec, the lineage's current DR load, and the measured real-world range; after it: audit retained margins, not just the new tolerance.

    push-dr-conditional-budget-conservationdr-tail-plant-continuationconstant-value-dr-overfits-margintask-shaping-before-plant-hardeningcom-randomization-forces-leg-spreadcom-dr-rollback-on-symptomthin-dr-judged-by-channel-coveragefriction-priority-re-measured-after-plant-change

  14. doctrine-14Gates measure what hardware feels: posture, margins, stripped assists

    Acceptance batteries carry posture-class rows (tilt max median, per-joint L/R asymmetry, temperature) beside task rows, graded margin columns beside binary gates, chirality scored per side, at least one condition that removes the environment's free stabilization, and validated predictive scalars promoted into the gate.

    Case. Three same-shaped judging errors - survival, displacement, wz-difference - all missed what the operator felt; posture metrics had the predictive power (`task-metrics-vs-posture-metrics`, `stand-gate-posture-not-survival`); binary survival saturated and hid a 60% margin gap (`constant-value-dr-overfits-margin`); v5 passed everything on the ground and failed suspended (`suspension-probe-removes-free-stabilizer`); the hip_roll (l+r) scalar predicted real drift direction and ordering and entered the battery (`hip-roll-sum-predicts-lateral-drift`); averages hide chirality (`chirality-scored-separately`); gait-quality gates are judged at speeds that demand a gait (`low-speed-commands-reward-dragging`). The recovery line added the rest of the kit: where failed episodes end, not only where they started (`end-state-confusion-matrix`); a frozen acceptance distribution with a pinned seed (`frozen-acceptance-distribution-and-pinned-seed`); video of the metric rollout itself (`video-as-acceptance-record`); and the admission that a 10 s episode cannot see a stance that fails after a minute (`episode-length-bounds-what-a-gate-sees`). The one-leg line removed a foot-spacing wall that no gate measured, and the feet met on hardware (`removed-wall-returns-on-hardware`).

    Coach application. Review every battery for posture rows, margin columns, per-side scoring, and an assist-stripped condition; when operator feel and gates disagree, suspect the metric class first.

    task-metrics-vs-posture-metricsstand-gate-posture-not-survivalconstant-value-dr-overfits-marginsuspension-probe-removes-free-stabilizerhip-roll-sum-predicts-lateral-driftchirality-scored-separatelylow-speed-commands-reward-draggingend-state-confusion-matrixfrozen-acceptance-distribution-and-pinned-seedvideo-as-acceptance-recordepisode-length-bounds-what-a-gate-seesremoved-wall-returns-on-hardware

  15. doctrine-15Fork and root selection: recoverability, maturity, frozen rewards

    Choose fork roots by which candidate's deficits the coming training can pay back (precision is recoverable; lost plasticity, symmetry, and margins are not); prefer mature checkpoints as roots even when younger ones score better as products; never fine-tune through a reward change - continuation is legal only with the reward frozen and plant/DR widening one rung at a time.

    Case. s1e-500 beat higher-precision candidates because its exclusive strengths were unrecoverable (`fork-root-recoverable-shortfall`); the b300 arm proved maturity is capital against adaptation shock (`root-maturity-vs-product-quality`); the B-arm scatter/half-recover/collapse signature falsified reward-change fine-tuning and drew the legal boundary for S2 continuation (`fine-tune-reward-change-falsified`).

    Coach application. For root debates, build the exclusive-strengths table and ask "which side can be trained back?"; require dual-arm evidence for maturity claims; classify any proposed continuation as reward-frozen or not before approving.

    fork-root-recoverable-shortfallroot-maturity-vs-product-qualityfine-tune-reward-change-falsified

  16. doctrine-16Curricula: verified engagement, lineage counters, disease-phase gating

    Automatic curricula must prove they engage (a saturated ratchet is constant DR wearing a curriculum's name); every ramp counts lineage-cumulative progress, not per-process steps; penalties aimed at late-stage pathologies ramp in after exploration noise decays; difficulty rises on measured per-stratum success, never on schedule.

    Case. The s1f ratchet capped at iter 248 and never engaged (`auto-curriculum-engagement-check`); the saturation ramp re-fired at +600 after every resume and no shipped product ever saw the penalty (`curriculum-counter-lineage-steps`); the same penalty worked once gated to the disease phase and became an untouchable mechanism (`gate-penalties-to-the-disease-phase`); record-high aggregate reward hid a fully-failing delay stratum (`aggregate-metrics-mask-subgroup-failure`); bucket share is not a gradient lever (`bucket-share-is-not-a-gradient-lever`). An assist curriculum keyed to a pooled success share was withdrawn on the strength of the categories that already worked (`curriculum-criterion-conditioned-on-lagging-category`); a pace set by per-step income moved only when that income was time-gated (`per-step-income-drives-speed-time-gate`), and the same gate had to be retired in a lineage without the disease (`time-gate-vs-wide-stance-retire-the-fix`).

    Coach application. Ask every curriculum three questions: does it engage (show the internal state)? what does it count (process or lineage)? when is it present (against the pathology's phase)? Check where shipped checkpoints sit relative to every ramp.

    auto-curriculum-engagement-checkcurriculum-counter-lineage-stepsgate-penalties-to-the-disease-phaseaggregate-metrics-mask-subgroup-failurebucket-share-is-not-a-gradient-levercurriculum-criterion-conditioned-on-lagging-categoryper-step-income-drives-speed-time-gatetime-gate-vs-wide-stance-retire-the-fix

  17. doctrine-17Probe before training: feasibility first, hypotheses in tables

    After two failed training attempts at a skill, stop training: demonstrate the behavior open-loop, enumerate hypotheses in a written table audited against actual configs cheapest-first, race one probe per side of the sim2real boundary for hardware-only pathologies, and use suspended tests to acquit or convict actuators before blaming authority.

    Case. "在黑暗里试钥匙" - four sidewalk rungs failed until an open-loop probe separated exploration/waveform/authority in one experiment (`open-loop-probe-before-reward-tuning`); the foot-drag mystery fell to a seven-hypothesis config audit (`hypothesis-table-code-audit`); the period-doubling was resolved by racing a reward-side and a plant-side evidence line - and both paid off, one per sub-case (`period-doubling-evidence-race`); the suspended test acquitted the roll actuator in one measurement (`suspended-test-isolates-actuator-authority`). A read-only configuration probe told a wall from a slope in the recovery line's seated basin (`configuration-probe-wall-not-slope`), and the fix it pointed to - where the feet are - took prone from 0/159 to 158/159 (`prone-dead-end-is-foot-placement`); a knob that did not move its variable was recorded as no test of the idea (`dof-vel-penalty-is-not-a-pacing-knob`).

    Coach application. When a skill resists training, prescribe the probe before any further reward edits; require verified target trajectories before imitation terms; keep a falsified-fixes list so closed roads stay closed (`amplitude-cut-falsified-yaw-fix`).

    open-loop-probe-before-reward-tuninghypothesis-table-code-auditperiod-doubling-evidence-racesuspended-test-isolates-actuator-authorityconfiguration-probe-wall-not-slopeprone-dead-end-is-foot-placementdof-vel-penalty-is-not-a-pacing-knobamplitude-cut-falsified-yaw-fix

  18. doctrine-18External advice is recomputed locally; values transfer as ratios

    Every external suggestion is classified adopt / already-have / modify / trap by recomputing its claim on the local reward table and probe data; numeric values transfer only as dimensionless ratios (to tracking weight, leg length, sqrt(gL), control rate); citations are verified to exist.

    Case. "Start vy very small" would have destroyed sidewalk learning on this reward table - the gradient scales quadratically (`external-advice-audit-against-own-arithmetic`); swing-height targets and weights transferred correctly only through leg-length and tracking-ratio scaling (`transfer-ratios-not-absolutes`); the "6-step delay" was refused for lacking a control rate (`latency-dr-covers-measured-pipeline`); a borrowed reference's structure was FK-verified and its amplitude re-derived from the division of labor (`reference-structure-fk-amplitude-division`); retrieval agents fabricated verbatim arXiv quotes - only source-verifiable material was used; and one dismissed suggestion later proved right for a different mechanism, and was credited (`cycle-average-tracking-for-gait-quantities`). An advisor's staged state machine turned out to exist in none of the three papers it cited, and reading them changed the plan (`advisor-paraphrase-vs-paper`).

    Coach application. Intercept every "paper X does Y" with the local recomputation; convert absolutes to ratios before comparison; verify quotes; revisit dismissed advice when new mechanisms appear.

    external-advice-audit-against-own-arithmetictransfer-ratios-not-absoluteslatency-dr-covers-measured-pipelinereference-structure-fk-amplitude-divisioncycle-average-tracking-for-gait-quantitiesadvisor-paraphrase-vs-paper

  19. doctrine-19Hardware sessions are scripted experiments, not tuning sessions

    Real-robot time executes a pre-registered matrix: risk-ordered (baseline first, fragile last with a spotter), stage-gated (suspended smoke before ground), A/B sessions bracketed by a repeated reference run, operators briefed on measured zero-command and untrained-axis behavior, chirality-aware disturbance protocols, no field tuning - the only legal field changes are scripted, single-variable, and self-reversing.

    Case. The S2 acceptance sheet (`risk-ordered-real-deployment`, `battery-bracketed-real-ab`, `know-zero-command-behavior`, `push-test-chirality-protocol`, `no-field-tuning-protocol`); the RAM-only torque experiment with automatic power-cycle rollback (`reversible-single-variable-field-experiments`); and the sim-veto rule - even sim's condemnations get one safeguarded hardware check when they judge the purpose-built configuration (`sim-veto-needs-real-confirmation`). The recovery line's first real run went ahead with its preconditions unmet and was stopped as dangerous (`first-real-get-up-violent-stage-one-policy`); after it: a staged hang, mat and floor protocol (`staged-hang-mat-floor-for-get-up`), a fixed power-cycle pre-flight and two-machine discipline (`power-cycle-preflight`, `two-machine-config-discipline`), a fall guard replaced rather than switched off (`fall-guard-becomes-a-state`), and logs that are part of the run (`hardware-log-is-the-attribution-input`).

    Coach application. Turn every hardware request into a runbook with order, gates, brackets, briefing, and anomaly plays; refuse improvised parameter changes on the floor.

    risk-ordered-real-deploymentbattery-bracketed-real-abknow-zero-command-behaviorpush-test-chirality-protocolno-field-tuning-protocolreversible-single-variable-field-experimentssim-veto-needs-real-confirmationfirst-real-get-up-violent-stage-one-policystaged-hang-mat-floor-for-get-uppower-cycle-preflighttwo-machine-config-disciplinefall-guard-becomes-a-statehardware-log-is-the-attribution-input

  20. doctrine-20Close questions in writing; restart when the debt is structural

    Audited questions get frozen verdicts with citable wording and an explicit reopening bar; hardware verdicts are dated by deployment-stack and calibration state and expire when those change; and when successive rungs shuffle symptoms without net progress, freeze the lineage as regression baselines, pay the structural debts, and retrain minimal - carrying laws and instruments, not weights.

    Case. The chirality and COM questions were closed with frozen wording and "no reopening without new hard evidence" (`frozen-verdicts-semantic-boundaries`); v5/v6's condemnations expired with the deploy stack (`stale-verdicts-under-old-stack`); a 2-degree calibration fix moved the whole runnable envelope (`zero-offset-calibration-shifts-envelope`); plant upgrades are era boundaries with paired re-baselining (`plant-swap-invariants-vs-shifts`); and the 2026-08-05 reset froze v5-v11, fixed the latency FIFO / manifest / sampling / reward-table debts, and restarted - producing the lineage that reached hardware SOTA (`freeze-lineage-fix-structure-restart`, `minimal-reward-table-with-provenance`). The recovery line's real-robot verdicts ended up in three places that disagree, one of them an undated note in a command file (`write-hardware-verdicts-back`).

    Coach application. Maintain the closed-questions ledger and quote it when symptoms recur; stamp verdicts with stack/calibration versions; when a team is three rungs into symptom-shuffling, raise the restart question explicitly with the freeze-fix-restart pattern.

    frozen-verdicts-semantic-boundariesstale-verdicts-under-old-stackzero-offset-calibration-shifts-envelopeplant-swap-invariants-vs-shiftsfreeze-lineage-fix-structure-restartminimal-reward-table-with-provenancewrite-hardware-verdicts-back

  21. doctrine-21Name the quantity in the space it lives in

    A goal, reward term or acceptance criterion about the feet, the base or the contact state is computed from the quantity itself - world poses, forces, per-category outcomes - never through a joint-angle, single-signal or pooled stand-in that assumes everything else sits at nominal; and every detector is validated on a behaviour known not to contain the event before it becomes a gate.

    Case. The recovery line was caught three times: |ankle roll| as "flat feet" sold stance width and the real robot slid into the splits, a hip-roll criterion was confounded by 50 deg of yaw, and the joint table said 0.271 m where the feet were 0.159 m apart; task-space terms produced the first flat, wide stance (`joint-space-proxy-for-task-space-quantity`). Flight detection lied in both directions across two lines - foot height flagged 40% false flight on a walking gait, contact force alone flagged slip chatter as hops (`contact-detector-single-signal-lies`). A pooled height average described a robot that did not exist - six in ten standing, four in ten sitting (`zero-partial-credit-is-not-an-iteration-problem`) - and the walking line had learned the same lesson on yaw rate (`heading-integral-not-body-rate`).

    Coach application. For every reward term and gate row, ask what physical quantity it stands for and whether it is measured directly; flag joint-space or single-signal stand-ins for task-space goals, ask for a detector validated on a negative control, and split pooled metrics by category before reading them.

    joint-space-proxy-for-task-space-quantitycontact-detector-single-signal-lieszero-partial-credit-is-not-an-iteration-problemheading-integral-not-body-rate

  22. doctrine-22Continuation needs a live gradient; a release is chosen by a scan

    Continue a converged policy only on a change that creates a live gradient, on a short budget, with every checkpoint scanned on the transfer axis; choose a release by running the full battery over a band of checkpoints and stop on signals, never by taking the last one; and when edits to the terminal phase cannot move a behaviour, roll back and retrain with the constraint present from the start, keeping the order in which the lineage acquired its mechanisms as explicit curriculum phases.

    Case. A continuation with no new gradient drifted MuJoCo transfer from 100/98% to 80/28% while every Isaac gate stayed perfect, and a live-gradient continuation at the same depth kept it (`converged-continuation-is-poison`). One-leg checkpoints 100 iterations apart failed 1 and 38 of 40 cells, and late ones degraded (`checkpoint-choice-is-a-full-gate-scan`). Four in-lineage stance fixes failed because the stance was the end of the get-up path, and from scratch it grew right (`stance-decided-by-get-up-path`); fixes stacked on degraded states were rolled back by the user (`stop-stacking-roll-back-and-audit`); and the lineage's final recipe, trained from scratch in one run, sat at 0% because the order of its curriculum was part of the product (`curriculum-history-is-part-of-the-product`). The omni line's short adaptation budgets and mature roots are the same law seen from the other side (`continuation-budget-not-from-zero`, `root-maturity-vs-product-quality`).

    Coach application. Before approving a continuation, ask for the new gradient, the budget and the transfer axis in the scan; before approving a release, ask for the scan; after three rungs without progress on the target, propose rolling back to the last good checkpoint and a from-scratch phase plan instead of a fourth patch.

    converged-continuation-is-poisoncheckpoint-choice-is-a-full-gate-scanstance-decided-by-get-up-pathstop-stacking-roll-back-and-auditcurriculum-history-is-part-of-the-productcontinuation-budget-not-from-zeroroot-maturity-vs-product-quality

Experience cards

70 cards matching “suspended-test-isolates-actuator-authority”.

  • A suspended (no-load) test acquits or convicts the actuator before you blame authoritysuspended-test-isolates-actuator-authority
    Mechanism understoodomnireal-acceptancehardwarereal-acceptanceattribution

    Before attributing a failure to actuator authority, measure no-load tracking error and steady-state torque fraction; blame authority only if the task fails while the error grows with demanded force - and then fix gains or targets, not training.

    Symptom

    hip_roll sagged 0.21 rad on the ground and saturation questions loomed over the sidewalk plan - was the roll axis physically too weak (authority), or was something else limiting it?

    Context

    Before C4, the roll-authority question was settled by measurement triage: suspended test (--suspend, feet off ground) showed hip_roll tracking error 0.0008 rad - actuator acquitted; the entire 0.21 rad ground sag is load-induced. Steady-state torque was 25% of limit - 75% margin remains. Since sidewalk needs lateral force, not exact angles, authority was ruled "not a hard limit", with a pre-registered criterion for when it WOULD become one: sidewalk fails to track AND roll error keeps growing - then the fix is raising hip_roll kp or lowering the vy target, not more training.

    Change

    Hypothesis "roll authority insufficient" demoted from blocker to a monitored branch with an explicit trigger condition; C4 proceeded.

    Outcome

    Later open-loop probes confirmed the actuator could produce the behavior (sidewalk feed-forward ran at full amplitude, 5/5 survival), and the eventual C4 failure causes were measurement and reward, never authority.

    Mechanism

    Suspended vs loaded comparison separates the actuator's closed-loop competence from the load path: tiny no-load tracking error means the motor/controller is fine and any loaded deviation is statics (gravity / stiffness budget, kp trading error for force). Torque-fraction measurement then bounds how much force headroom actually remains.

    Applies when

    • suspecting an axis is "too weak" for a new skill
    • large position sag on a loaded joint
    • deciding between hardware fix, gain change, and more training
    “吊挂(--suspend)实测 hip_roll 跟踪误差 0.0008 rad → 执行器无罪,地面下垂 0.21 rad 全是负载所致;稳态占限扭 25% → 仍有 75% 扭矩余量。… 判据:若 C4 出现「侧走跟不动且 roll 误差继续变大」,那才是权限账 … 解法是提 hip_roll 的 kp 或降 vy 目标,不是硬训。”
    train/C_LADDER_RUN.md § 3d. roll 权限:已部分澄清,不是硬上限
  • Size each joint's action authority to its measured working range - lock a channel to zero only when its job is provably elsewhereper-joint-action-scale-lockdown
    Observed oncewalkobservation-designobservation-honestyreward-shapingcontract-freeze

    Set per-joint action scales from measured target ranges and momentum decompositions: full authority for working channels, working-range authority for balance channels, zero for channels whose contribution is measured negligible - and prefer this structural quieting over perpetual reward penalties, keeping the contract dimensions intact.

    Symptom

    "Walks crooked" - roll and yaw channels wandered; hip_yaw peak-to-peak reached 22.3 deg in v11 while contributing essentially nothing to locomotion; a uniform action scale of 0.5 gave every joint the same authority regardless of its actual job.

    Context

    The v12 design replaced the scalar action scale with per-joint scales justified by measurements: pitch-class 0.5 (the gait's entire working channel - untouched); hip_yaw 0.0 - lossless because it carries only 1.4% of yaw momentum (v6 decomposition) and straight-line targets use merely +/-0.006-0.03 ("乱动纯属浪费"); roll 0.2 - NOT zero, because lateral balance and weight transfer are roll's unique job (locking it would degenerate into foot-edge rocking, "比现在更歪"), and 0.2 covers the measured working range +/-0.06-0.19 while "0.5 的另一半全是 '歪歪扭扭'的来源". Costs were accepted consciously: turning demoted to an observation row with a fallback (yaw 0 -> 0.1 in v13). Contract preserved: the 12-dim action interface unchanged, yaw values simply neutralized. The structural lockdown also RETIRED the reward-side hip_yaw_quiet penalty - "A 的 yaw=0 结构性取代,不再付奖励塑形成本".

    Change

    action_scale_joint pitch 0.5 / roll 0.2 / yaw 0.0 wired through robot.yaml -> policy_io (verified: all-ones action gives hip_yaw target exactly 0) -> Isaac action term, guarded by the contract checker ("它就是抓这种双侧不一致的").

    Outcome

    Designed and verified on the shared side before the lineage freeze; stands as the pattern for authority sizing: structure replaces reward shaping wherever a channel should simply not act.

    Mechanism

    Action scale is a per-channel authority budget; uniform budgets give noise channels the same voice as working channels, and reward-side quieting then pays a permanent shaping tax for what a zero scale provides for free. But zeroing is only lossless when decomposition proves the channel's contribution negligible AND no unique function (balance) lives there.

    Conflicts

    Wired and verified on the config/deploy side but never trained - the 2026-08-05 reset suspended v12 before the Isaac-side run.

    Applies when

    • some joints wander without contributing to the task
    • a quieting penalty (deviation/L1) taxes every step forever
    • deciding action-space authority for a new task or robot
    “yaw=0 是无损的:实测它只贡献 1.4% 偏航动量、直行目标只 ±0.006~0.03,乱动纯属浪费。… roll 不能为 0:横向平衡/重心换脚是它的独有职责,锁死会退化成脚缘摇摆(比现在更歪)。0.2 的依据:各代实测 roll 目标只用 ±0.06~0.19,0.5 的另一半全是"歪歪扭扭"的来源。”
    train/WALK_V12_SPEC.md § 3. A —— 逐关节动作幅度(用户"只动 pitch"的安全版)
  • Anchoring the action on the measured joint angle (target = q + beta*a), with a beta curriculum down to tau_limit/kp, bounded torque by construction, removed the re-falls and later stood the robot up on hardwarebeta-anchored-action-target
    Mechanism understoodrecoverytraining-runactuator-modelingcontract-freezecurriculum

    For large-motion skills on position-controlled actuators, bound the action relative to the measured joint angle with a per-joint authority of tau_limit/kp, curriculum the authority down from full range, keep the curriculum state out of the observation and pin acceptance at the deployed authority - and make the deployment code refuse to run the anchored contract without a measured q.

    Symptom

    The V0 full-range absolute action produced violent targets; the V1 command-anchored rate limit made standing oscillate. Both failure modes came from how the action becomes a target.

    Context

    V2.0 (user approved, from scratch): BetaAnchorJointPositionAction, target = q_measured + beta_j(m)*a, memoryless per step. beta_j(m) = floor + m*(beta0 - floor), beta0 = the contract half-range (m = 1 reproduces V0 authority), floor = min(tau_limit/kp, beta0): hip_pitch 1.309 -> 0.40, knee 1.047 -> 0.40, hip_yaw -> 0.917, the other joints unchanged - the tightening lands exactly on the joints the V0 torque account convicted. m drops 0.1 per step when a standing-share EMA exceeds 0.35. beta is NOT in the observation, so the 45-dim contract is untouched; acceptance is pinned at m = 0 because the Python curriculum state is not saved in the checkpoint. The deployment chain got a new profile (recovery_v2: action_anchor current_q, explicit per-joint beta written into the contract, independent of the gain profile), and policy_io raises if q is missing rather than silently falling back to the absolute contract; the old profile's check reproduced its pre-change deviation bit for bit.

    Change

    New action term and beta curriculum; later the RS06 floor was lowered 0.40 -> 0.30 -> 0.25 (kp*beta 7.5 N*m) and the stamped deployment profile was synced to 0.25.

    Outcome

    First acceptance at m = 0 (v2_0b): re-falls 0% in every category, the torque gate passed for the first time on the line (worst 69.9%), knee jitter 0.004; supine 98.8 / side 88.8% with prone and mid still failing (fixed by the conditional pull curriculum). MuJoCo showed demand at or under the limits (hip_pitch 11.7/12 against V0's 26.8). Lowering beta cut impact (hip_pitch demand 9.7 -> 8.5 N*m) but barely slowed the get-up - it had become coordination-limited. Enabling the policy moves the target only +/-beta around the current pose, so there is no homing fling; the 08-11 real get-up and the later v3_1p1c both run on this contract.

    Mechanism

    kp*beta caps the proportional torque in a single step with no build-up delay and no memory, giving both a hard impact bound and full balance bandwidth.

    Applies when

    • a skill needs full joint range but hardware torque limits are low
    • absolute position targets cause impacts or saturation
    • changing the action semantics of a contract that deployed policies share
    “**动作项** `BetaAnchorJointPositionAction`:`target = q_实测 + β_j(m)·a`, 逐步无记忆 … **Play/验收钉 m=0(= floor = 部署档)**:python 课程状态不进 checkpoint, Play cfg 显式 `beta_m_start=0` … 判读:**结构赌注兑现** —— 站姿零再摔 + 力矩账首过(kp·β 封顶按构造)”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §33 V2.0 预注册(2026-08-10,用户点头开工):β 锚定动作空间,从零训
  • Ideal PD is not enough - add a delay buffer and fit armature/friction/delay per jointactuator-delay-buffer-fitting
    Observed oncewalkactuator-modelingactuator-modelingplant-calibration

    Never ship ideal PD to hardware: add a measured delay (in control steps) and per-joint armature/friction fitted from step and sine responses, and treat remaining actuator mismatch as your standing largest sim2real residual.

    Symptom

    Standard ideal PD actuator model transfers poorly; sim assumes targets take effect instantly and joints reach arbitrary acceleration.

    Context

    A developer with a successful on-hardware Isaac Lab biped modified the actuator model in two ways and calibrated it against the real robot: step-response plus sine-sweep tests (positive step, negative step, sine tracking), overlaying sim curves on measured curves and hand-tuning.

    Change

    (1) Delay buffer: action targets take effect after a uniform 6 time-step delay on all joints; (2) acceleration limiting so the actuator cannot reach arbitrary acceleration; (3) per-joint fit of armature / friction / delay - different joints genuinely needed different values.

    Outcome

    Hip joints fit worst, knee best; the developer rated the result "not perfect, the best I could do" and still listed actuator-model improvement as next work - i.e. even the fitted model remained the dominant residual.

    Mechanism

    Real actuation is a lagged, bandwidth-limited system; a delay buffer and acceleration cap are the two cheapest structures that reproduce its phase and magnitude response. Per-joint differences come from differing load, wiring, and friction states, so a single global constant underfits.

    Applies when

    • actuator model in sim is ideal PD with no delay
    • step-response of real joint visibly lags or overshoots the sim's
    • budgeting which sim2real gap to attack first
    “标准 ideal PD actuator 不够用,他改了两处:延迟缓冲:目标不是立即生效,全部关节统一 6 个 time step 延迟 / 加速度曲线:执行器不能瞬间达到任意加速度 … 用 armature / friction / delay 三个参数逐关节拟合,标定方法是阶跃响应 + 正弦扫描 … 髋部关节偏差最大,膝关节最好。”
    Experience.md § 执行器建模 —— 最值得抄的一条 (lines 50-59)
  • The action-delay was implemented as lerp - beyond one step it extrapolated BACKWARD, so a whole lineage trained on a fictitious actuatorlatency-lerp-reverse-extrapolation
    Mechanism understoodinfraactuator-modelingactuator-modelingplant-calibrationsim2sim

    Unit-test plant-model code (delays, filters, randomizers) against hand-computed truth across its FULL configured range, not just the nominal case - a delay must be a queue, and any interpolation used outside [0,1] is a silent plant corruption that training will faithfully absorb.

    Symptom

    Every walk/stand model up to v11 had been trained on a silently wrong plant: the action-latency implementation lerp(cur, prev, lag) is only an interpolation for lag <= 1 - at lag 3 it computes 3*prev - 2*cur, a REVERSE extrapolation. With the configured (0, 0.06) s at 50 Hz (lag in [0,3]), about 2/3 of environments were adapting to actuator dynamics that do not exist.

    Context

    Listed as evidence item #1 for the full restart: "全部旧模型训在错误 plant 上" and the head suspect for the real robot's wild kicking. The fix replaced it with a true FIFO delay line (commit 7f13793) plus its own regression test (tests/test_action_latency.py) - but every exported ONNX predated the fix, which is part of why the lineage was frozen rather than patched.

    Change

    Delay implementation rewritten as an honest FIFO with unit tests; the restart baseline trained on the corrected plant from day one.

    Outcome

    A generation-scale training investment was revealed to have a corrupt plant underneath; the class of bug (plausible-looking math that silently changes meaning outside its valid range) got a permanent test.

    Mechanism

    lerp(a, b, w) leaves the segment for w > 1; used as a delay it fabricates high-gain inverted dynamics precisely in the largest-delay draws, so the policy learns compensation for an actuator that cannot exist - and DR then trains robustness to the artifact rather than to reality. No training metric can catch this: the sim is self-consistent, just wrong.

    Applies when

    • implementing or auditing action delay / filtering in a trainer
    • a lineage behaves as if compensating dynamics nobody modeled
    • deciding whether old checkpoints are salvageable after a plant bug
    “动作延迟旧实现 lerp(cur, prev, lag) 在 lag>1 时是反向外插(w=3 → 3·prev−2·cur),配置 [0,0.06]s@50Hz 即 lag∈[0,3],约 2/3 env 在适应不存在的执行器动态。7f13793 已换真 FIFO,但所有 ONNX 均训于修复之前 —— 真机"乱踢"的头号嫌疑。”
    train/OMNI_V0_SPEC.md § 0. 为什么从零 (1)
  • action_rate weight is the sim2real bandwidth knob - re-tune it whenever a rate limiter is removedaction-rate-weight-vs-bandwidth
    Observed oncewalkreward-shapingaction-ratereward-shapingactuator-modeling

    Set action_rate weight relative to real actuator bandwidth, and re-tune it any time another smoothing/limiting element (filter, slew limiter, gain) changes - reward weights are load-bearing parts of the actuator model.

    Symptom

    With a low action_rate_l2 weight the policy learns fast actions; the unmodeled part of the actuator response is then excited hardest, and sim2real "直接崩" (collapses outright). With too high a weight, actions become so slow the robot cannot maintain balance.

    Context

    The reference developer called action_rate_l2 the single most important reward for transfer, with side-by-side video evidence that the high-penalty, slower policy is clearly better on hardware. Lucen context: the team had just removed the SOFT_SPD=1.0 velocity limiter, which had been an implicit actuator-bandwidth constraint - leaving action_rate as the only remaining constraint on action speed.

    Change

    Decision recorded: after removing SOFT_SPD, re-evaluate the action_rate weight rather than keep the old value, since its effective role changed from "additional smoother" to "sole bandwidth constraint".

    Outcome

    Logged as a priority follow-up ("重新评估 action_rate 权重 - 拆掉 SOFT_SPD 之后这一项的作用变了"); the failure mode it guards against is training high-frequency actions the real actuators cannot track.

    Mechanism

    Slower actions stay inside the frequency band where the ideal-PD sim actuator and the real actuator agree; fast actions probe the band where unmodeled delay, inductance, and bandwidth limits dominate, so model error is amplified in exact proportion to action speed. Any removed external rate limit transfers that constraint's entire job onto the action_rate penalty.

    Conflicts

    The low/high tradeoff evidence is the external developer's report (with video); the Lucen-side entry is a pre-registered risk and decision, not yet an on-robot A/B at the time of writing.

    Applies when

    • removing or adding an action filter, slew limiter, or low-level speed cap
    • real robot shows high-frequency chatter or overheating absent in sim
    • tuning smoothness rewards before a hardware deployment
    “权重低 → 动作快 → 执行器模型不准的部分被放大,sim2real 直接崩 / 权重高 → 动作慢 → 好迁移,但可能慢到无法维持平衡 … 我们刚拆掉 SOFT_SPD=1.0 的限速器,等于把执行器带宽约束整个移除了。action_rate 惩罚现在是唯一还在约束动作速率的东西,需要重新评估权重”
    Experience.md § action_rate_l2 是他认为最关键的 reward (lines 61-70)
  • Add a single-point-suspension test to acceptance - the ground is a free stabilizer that hides divergencesuspension-probe-removes-free-stabilizer
    Mechanism understoodwalkgate-batterygate-batteryreal-acceptancesim2sim

    Include at least one acceptance condition that strips the environment's free stabilization (suspension, or equivalent) - the sim-passing policy that fails on hardware is often failing a condition the battery never posed.

    Symptom

    walk_v5 looked healthy in every on-ground sim test yet diverged on the real robot - the acceptance battery had never measured a condition that would have revealed it.

    Context

    The battery gained a single-point-suspension probe (robot hung, feet free): measure torso tilt while the policy runs without ground contact. v5 scored 45.9 deg mean tilt suspended - wildly unstable - which the file calls "最灵敏的失稳探针(拿掉地面这个免费稳定器)": ground reaction forces passively stabilize a marginal policy, so on-ground metrics saturate long before the policy's internal balance is actually sound. v6 halved it (23.0 deg, target <10 deg) - progress visible on a scale where on-ground numbers showed nothing.

    Change

    Suspended-tilt added as a standing acceptance row; run under the honest contact parameters battery (accept_v2 with measured condim 4 / torsional friction 0.035), under which v5 correctly FAILS in agreement with the real robot.

    Outcome

    The sim battery's verdict on v5 flipped from pass to fail, matching hardware; suspended tilt became the discriminating metric between v5 and v6 (45.9 vs 23.0 deg) when ground metrics differed little.

    Mechanism

    Contact with the ground closes a stabilizing feedback loop the policy gets for free; removing it exposes the policy's own attitude control authority. A metric measured only in the assisted condition cannot rank policies by the unassisted quantity that hardware will actually demand during perturbations and flight phases.

    Applies when

    • sim acceptance passes but hardware diverges
    • designing an acceptance battery for a legged robot
    • two candidates tie on ground metrics
    “单点吊那条是最灵敏的失稳探针(拿掉地面这个"免费稳定器"), v5 在地上一切正常却在真机发散, 就是因为验收从没测过这个工况。”
    train/WALK_V6_MINIMAL.md § 5. 验收
  • Training at scale 0.4 is NOT the twin of deploying 0.5 at power 0.8 - the algebra matches, the learned policy does notdeploy-scaling-not-training-equivalent
    Mechanism understoodomniattributionattributioncontract-freezesim2simcurriculum

    Never assume deploy-side scalings can be folded into training-time constants ("burning the crutch into training"): the learned optimum depends on the training-time authority, so treat such conversions as full experiments with pre-registered expectations and a sim2sim gate before any hardware.

    Symptom

    s1g (S1.6) trained from zero at action_scale 0.4 - meant as the "training twin" of the hardware-proven s1c-at-power-0.8 (0.8 x 0.5 = 0.4) - was all green in Isaac (zero falls, reward 117) yet scored 0/3 across all eight checkpoints and 0/20 at 20 seeds in the MuJoCo gate, falling forward at median 1.57 s with a 2.9x speed overshoot.

    Context

    The pre-registered expectation (survival gate should pass, since the conviction matrix showed s1c@0.8+delay2 all-survive) was cleanly falsified, and the harness was acquitted by controls: --delay 0 fell identically (not a delay fragility), check_contract all green, and s1c through the same harness survived 2/3. The verdict: "「s1c@0.8 = 0.4 训练孪生」的代数等价不成立" - a policy deployed with a derated output still LIVES in the 0.5 internal model it trained under (its value function, its expectations of its own authority), while a policy that starts training with reduced authority learns a different, clip-hugging gait with zero margin for plant differences ("部署端打折的策略活在 0.5 的内模里,训练起点收权限学出的是贴 clip 的 另一套步态,对 plant 差异零余量"). Result: the policy was withdrawn before hardware ("撤回——不上真机"), the lineage root moved back to the 0.5-contract s1c-5500, and this became the C ladder's cited fact-check ("s1g 是 0/20 证伪出局的那一代").

    Change

    The amplitude-surgery route abandoned; contract kept at scale 0.5; the deploy-side 0.8 crutch later retired on its own merits when the delay-complete s1e generation ran at full power.

    Outcome

    One training run bought a clean falsification of a plausible algebraic identity; no hardware time was spent on it because the sim2sim gate caught it.

    Mechanism

    Output scaling commutes with the network arithmetic but not with learning: the training-time scale shapes which gait solutions are reachable and how much clip headroom the optimum keeps. A derated mature policy retains the wide-authority solution executed softly; a from-zero narrow-authority policy finds a different optimum that saturates its smaller envelope - the two are not the same controller in different units.

    Applies when

    • proposing to move a deployment derating into a training constant
    • a scaled-down contract policy hugs the action clip
    • Isaac-green / cross-sim-zero results on a re-scaled lineage
    “预注册 a) 证伪——Isaac 全绿(零摔/reward 117)但 MuJoCo --delay 2 八档 checkpoint 扫描全数 0/3、iter6500 20-seed 0/20 … 「s1c@0.8 = 0.4 训练孪生」的代数等价不成立: 部署端打折的策略活在 0.5 的内模里,训练起点收权限学出的是贴 clip 的另一套步态,对 plant 差异零余量。”
    train/OMNI_V0_SPEC.md § 3. S1.6 判决(2026-08-07 验收)
  • A 2-degree joint-zero calibration fix moved the whole runnable envelope - re-test old "cannot run" verdicts after recalibrationzero-offset-calibration-shifts-envelope
    Observed onceomnireal-deployreal-acceptancehardwareplant-calibrationattribution

    Date every hardware verdict with the calibration state; after any zero/mount recalibration, re-test previously condemned policy-power combinations and previously "unexplainable" posture offsets before attributing either to training or model.

    Symptom

    s1d was on record as "only runs at power 0.7" (kicked wildly at 0.8); after a calibration pass, the same policy ran 12 s at 0.8 with no kicking at all.

    Context

    The calibration had fixed a 2.08 deg zero offset on r_hip_roll - exactly the constant error source on the dominant joint of the kicking oscillation loop ("恰是乱踢振荡环主导关节的常值误差源"). The three-generation post-calibration hardware sweep also closed a second case: the robot's mysterious "backward lean" disappeared after calibration, and the sim-real posture difference collapsed from opposite-sign 5+ deg to same-sign ~2 deg ("后仰案实质了结") - the lean had been a sensing/zero artifact, not a mass-model error. Booked consequence: if the s1d recovery re-verifies, "真机可跑档整体 上移" - every policy's runnable power envelope shifts up, and downstream lineages' hardware expectations get revised.

    Change

    Joint-zero and mount calibration promoted from setup chore to a variable that dates hardware verdicts: verdicts about which power/scale levels a policy can run are conditioned on the calibration state they were measured under.

    Outcome

    One policy rehabilitated at a higher power level; one standing sim-real posture discrepancy closed without touching model or training; a pending re-verification booked rather than asserted.

    Mechanism

    A constant joint-zero error acts as a persistent disturbance injected at the feedback loop's most-loaded joint; near an oscillation threshold, removing a 2-degree bias is the difference between a stable and an unstable loop. Since the error is additive and machine-side, it shifts every policy's stability envelope simultaneously - which is why verdicts must carry their calibration date.

    Conflicts

    The s1d rehabilitation awaited one confirming re-run at the time of writing ("待复核一跑坐实") - the offset-as-cause reading is the head suspect, not a closed verdict.

    Applies when

    • a policy oscillates at a power level others tolerate
    • sim and real disagree on a constant posture offset
    • deciding whether to re-test old hardware verdicts after maintenance/calibration
    “发现①:s1d@0.8 能跑了(旧账「只有 0.7 能跑」)——12s 无乱踢。头号嫌疑 = 标定修正:r_hip_roll offset 修 2.08°,恰是乱踢振荡环主导关节的常值误差源。… 发现②:「后仰」标定后消失 … sim-real 姿态差从反号 5°+ 收敛到同号 2°,后仰案实质了结。”
    train/README.md § 真机 @0.8 三代横评(2026-08-07 标定后)
  • Armature must be N^2 x rotor inertia, never 0 - measure it no-loadarmature-n2-rotor-inertia
    Mechanism understoodwalkplant-calibrationplant-calibrationactuator-modeling

    Every geared actuator carries N^2 * I_rotor of reflected inertia at the joint; set armature from a no-load measurement, never leave it 0 and never guess it.

    Symptom

    Sim joints accelerate more easily than real joints; old MJCF had armature = 0 (rotor reflected inertia entirely unmodeled), a systematic sim2real gap on every joint.

    Context

    Original hand-written MJCF plant used armature 0. The team derived and then measured the correct value: torque needed at the rotor is I_rotor * N * alpha; after the N:1 gearbox the output shaft "feels" an extra N^2 * I_rotor of inertia. With a 9:1 reduction that is an 81x amplification of the rotor inertia, far too large to ignore.

    Change

    Set per-motor armature from no-load (motor out of the robot) measurement instead of 0: RS06 = 0.0070 kg*m^2, RS02 = 0.0032 kg*m^2, RS00 = 0.0015 kg*m^2. Landed together with measured friction as the first fully-measured plant parameter set.

    Outcome

    Plant parameters "第一次全部来自实测" (first time all from measurement); became the frozen plant baseline for all subsequent training generations.

    Mechanism

    Reflected inertia scales with the square of the gear ratio: the rotor spins N times faster than the joint, so its kinetic energy (and the torque needed to accelerate it) appears N^2 larger at the output. Omitting it makes simulated joints unrealistically fast/light, so policies learn action rates the real actuator cannot deliver.

    Applies when

    • building or auditing a simulation plant model for a geared/QDD actuator
    • sim policy moves joints faster or snappier than the real robot can
    • MJCF/URDF review shows armature or rotor inertia set to 0 or a default
    “armature 转子反射惯量有问题 在sim里面一定要处理 不能是0,空机测试。转子处需要的力矩 = I_rotor × N × α 经减速箱放大 N 倍后 = N² × I_rotor × α 所以输出轴"感觉到"多了一个 N² × I_rotor 的惯量。 这就是 armature。… 关键是那个平方。减速比 9:1 就放大 81 倍。”
    Experience.md § # armature 转子反射惯量有问题 (line 9)
  • Two simulators disagreed 1.8x on one policy's torque demand - four explanations were eliminated with numbers, the surviving suspect was never tested, and neither reading was allowed to cancel the othertorque-disagreement-between-simulators-unresolved
    Hypothesisrecoverysim2sim-gatesim2simactuator-modelingattribution

    When two simulators disagree on a safety-relevant quantity, eliminate the measurement explanations one at a time with numbers, name the survivor as a hypothesis, keep the pessimistic reading binding, and run the direct test (replay one action sequence open-loop through both plants) before the quantity is used to pass a gate for hardware.

    Symptom

    For R3.0, Isaac read hip_pitch torque demand at 75-80% of the limit (PASS); MuJoCo read the same policy at 148-152% (1.5x over the limit).

    Context

    Candidates were eliminated one by one: PD gains (identical, RS06 kp 30 / kd 1.5), the settle window (both skip the first 0.5 s), the statistic (worse-of-two-legs vs per-joint - explains ~15%), self-collision (the no-contact subset still read 152%), sampling (500 Hz peak vs 50 Hz sample - ~9%). About 1.8x remained. The prime suspect - Isaac's implicit actuator (PD solved inside the PhysX integration, chosen to mimic kHz firmware PD) against MuJoCo's 500 Hz explicit PD - was named but untested.

    Change

    The Isaac PASS was recorded as valid for the Isaac plant only; the prescribed decider was an open-loop replay of one action sequence through both plants, compared step by step, needing no training. It was upgraded to a precondition of R3.1.

    Outcome

    R3.1 ran in parallel with, not after, the replay, and the replay never appears as done. By §40 it was "the oldest open account" on the line, to be fed by real-robot logs - which the spec also never records. Meanwhile the 50 Hz sample under-read the peak by 34% as smoothing narrowed the spikes, so Isaac-side readings grew more optimistic exactly when the comparison mattered more.

    Mechanism

    Each measurement artifact explained a slice of the gap; what remained is a plant difference, and an untested plant hypothesis cannot license discarding the pessimistic simulator on a safety-relevant quantity.

    Conflicts

    The spec prescribes the open-loop replay (§23), upgrades it to an R3.1 precondition, then records that R3.1 ran in parallel without it (§24), and lists it as the oldest open account before hardware (§40); nothing through §50 (2026-08-14) records a result. Every later "torque gate PASS" on this line is an Isaac-plant reading plus a MuJoCo check, never a reconciled one.

    Applies when

    • Isaac and MuJoCo (or sim and hardware) report different torques, contacts or slips
    • implicit vs explicit actuator models are in play
    • a gate passes on one simulator only
    “**同一个策略,一侧判 PASS 一侧判超限 1.5 倍。** … 口径项全部扣掉后仍剩 **~1.8×** 没有解释。 … 但**这条没有验证,不能拿它当结论去抵消 MuJoCo 的读数**。 … (做法:拿同一条 动作序列在两边开环回放,逐拍比 τ —— 不需要重训)”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §23 MuJoCo 复核门:成功率更稳,但 τ 与 Isaac 差 ~1.8× 没收敛
  • Torque caps cannot soften footfalls - impact is falling-mass momentum, only the reward can treat itlanding-impact-not-fixed-by-torque-caps
    Mechanism understoodwalkreward-shapingreward-shapinghardwareactuator-modeling

    Classify each hardware symptom by the physics that sets it: quantities fixed by ballistic momentum at contact must be treated through the policy's trajectory (reward terms on approach velocity/force), never through actuator caps - and size such penalty weights against your own tracking reward, not a lighter robot's.

    Symptom

    Footfalls slammed at 1.78x body weight in sim baseline (human walking: 1.2-1.5x); the tempting hardware-side fix was cutting actuator torque limits.

    Context

    Measured directly: scaling torque limits from x1.0 down to x0.4 left peak landing force essentially unchanged (1.75 -> 1.78x body weight) - the impact force comes from the momentum of the falling mass at touchdown, not from motor effort. The fix has to change the trajectory, i.e. the policy, i.e. the reward: feet_contact_forces penalty above a threshold of 113 N (= 1.2x the 9.58 kg robot's weight), clipped, weight -0.005. The weight was sized locally, not copied: the reference robot's -0.001 would amount to 0.9% of tracking reward on this robot ("策略不会理它" - the policy would ignore it); -0.005 gives 4.4%.

    Change

    Added threshold-type contact-force penalty (-0.005, threshold 1.2x body weight) as one of v6-minimal's three changes; hardware torque cuts explicitly rejected as a footfall treatment.

    Outcome

    Landing force 1.72x -> 1.55x by v6 (target <1.5x, missed by 3% - progress booked honestly); the torque-cap dead end was documented so it would not be retried.

    Mechanism

    At touchdown the ground stops a ballistic mass; the impulse is set by approach velocity and effective inertia, which motors can no longer influence in the final instant. Only earlier trajectory choices (approach velocity, timing) reduce it - and those are selected by the reward, not by actuator limits.

    Applies when

    • footfall impact or landing noise on hardware
    • proposals to derate torque as a softness fix
    • importing contact-force penalty weights from another robot
    “⚠️ 硬件限扭降不了落脚力 —— 砸地力来自下落质量的动量: 实测 tau ×1.0→×0.4, 落脚力 1.75→1.78× 体重纹丝不动。只有这条奖励能治。… ⚠️ 权重不能用 Pi 的 −0.001 —— 实测在我们身上只占跟踪奖励的 0.9%, 策略不会理它 (Pi 6.94 kg 更轻)。−0.005 给到 4.4%。”
    train/WALK_V6_MINIMAL.md § ③ 新增 feet_contact_forces
  • Order hardware runs by sim risk, gate each stage on the last, and put the fragile cell last with a spotterrisk-ordered-real-deployment
    Replicatedomnireal-deployreal-acceptanceprocess

    Script hardware sessions as a risk ladder: baseline first, sim-riskiest last with a spotter, suspended smoke before ground, each stage gated on the previous, environment (floor mu) recorded as a selection input - and stop at the stage that misbehaves.

    Symptom

    Five policy-x-gain combinations had to go on hardware in one session, with sim survival ranging from 20/20 down to 17/20 (and zero-command survival down to 2/20) - an unordered session risks breaking the robot on an avoidable run.

    Context

    The execution sheet fixed the order as sim-risk low to high, control baseline first (current SOTA establishes the floor reference), the fragile cell (fric-2400@kd1.0) last with a person spotting throughout. Stage gating: suspended smoke (feet off ground, 10 s each, all five pass before anything touches down) -> suspended with IMU and forward command (gait forms in the air) -> grounded runs -> speed raise only for combos that survived the previous stage -> zero-command tests only with a spotter, ordered by sim zero-cmd survival, with the 2/20 cell skipped by default. Preconditions include recording the floor material and estimating mu (if mu <~0.6, sim says pick the kd1.2 gain as main), port/CAN self-check, calibration frozen. Any stage failing stops the session at that stage: "任一段出问题就停在那一段, 不要跳到下一段".

    Change

    Session structured as a risk ladder with per-stage gates instead of a flat checklist; per-combo sim survival numbers written into the run table as the ordering key.

    Outcome

    The session design localized any failure to the cheapest stage that could reveal it, kept the robot safe for the informative fragile run, and made the control baseline available before any comparison run.

    Mechanism

    Hardware sessions consume a shared budget (robot integrity, battery, floor time); ordering by predicted risk means information is bought cheapest-first, and stage gates convert an expensive failure into a cheap earlier one. Baselines run first because every later reading is relative to them.

    Applies when

    • taking multiple policies/configs to hardware in one session
    • a candidate is known-fragile in sim but must be measured
    • writing a deployment runbook for a new robot
    “跑序 = sim 风险从低到高, 最险的放最后 (依据 = 存活门/零指令存活) … ⑤ 是 sim 里最脆的一格 … 放最后跑, 全程留人扶, 起步即给 cmd, 零指令不做。… 任一段出问题就停在那一段, 不要跳到下一段。”
    train/REAL_RUN_S2.md § 上机名单 / 全部命令
  • A stronger action_rate penalty cut the median torque demand under the gate and left the p99 at 4x the limit - only a hinge on the pre-clip (computed) torque, weighted by comparison with a peer term, collapsed the tailtail-torque-needs-hinge-on-computed-demand
    Mechanism understoodrecoveryreward-shapingactuator-modelingreward-shapingmeasurement

    Judge actuator demand against the deployed limit, read the pre-clip demand (applied torque is censored and gives no gradient on the excess), use an L2 rate penalty for the median and a thresholded hinge on computed demand for the tail, and set a new term's weight from its measured steady magnitude next to a peer term rather than from a back-of-envelope estimate.

    Symptom

    After R0.5 hip_pitch delivered torque sat at its 12 N*m limit in a typical get-up (demand 119-125% of the limit, p99 4.2x) - zero control margin at exactly the moment modelling error matters.

    Context

    The 12/17/11 N*m limits are deployment limits written into robot.yaml by set_torque (RS06 at 33% of rated), and simulation uses the same effort_limit - so the gate is judged against them, not the 36 N*m rating (an early reading against the rating was retracted). Applied torque is clipped at the limit - censored data - so demand must be read from computed_torque. With the full-range action contract (hip_pitch scale 1.309, kp 30) a single-step action change of 0.306 already saturates hip_pitch, and action_rate penalizes exactly that change.

    Change

    R3.0: action_rate_l2 -0.01 -> -0.03 (child-run). R3.1: new torque_headroom = sum relu(|tau_computed|/limit - 0.9)^2, normalized so three motor types share a scale. Its weight was first estimated at -0.1, measured in a 12-iteration run at an effective -0.019 (12x smaller - the estimate had mixed a per-episode-peak p99 with a per-step p99, and at 1% of upright it would have been numerically absent), and set to -0.5 so its steady value (-0.095) matched action_rate's (-0.097).

    Outcome

    R3.0: sum |da|^2 -64%, success 99.6 -> 100%, delivered median = demand median (the clamp no longer fired in a typical episode), gate PASS at worst 79.9% - but p99 unchanged (hip_pitch 419-432% -> 427-436%). R3.1: p99 hip_pitch -> 148-189% (-57 to -65%), knee 422-439% -> 233-234%, saturation duty -60%, success 100%; the worst joint became hip_roll at 67.7%. Its cost appears in torque-penalty-bought-by-leg-bracing.

    Mechanism

    A squared-rate penalty presses the whole-episode sum and moves the typical step, not rare spikes; the spikes came from the kp term (large targets while a limb is blocked by the ground - velocity alone could not reach them under vel_limit), and a penalty on applied torque cannot see demand above the clip because every excess sample reads as exactly the limit.

    Applies when

    • torque demand saturates actuator limits in high-effort skills
    • a smoothness penalty improves medians but not peaks
    • a new reward term's weight is set by estimate alone
    “**必须用 `computed_torque` 而不是 `applied_torque`**:后者被 `effort_limit` 削平, 是删失数据,超限样本全被压成"恰好等于限",对超限部分梯度恒为 0。 … 改按同侪定标取 **−0.5**(稳态 ≈ −0.095,与 `action_rate_l2` 的 −0.097 等量)。”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §24 R3.1(torque_headroom 力矩需求越限罚)
  • Push-test protocol - positive side first, fragile side spotted, axes aligned in the log, and cross-machine push counts stay qualitativepush-test-chirality-protocol
    Mechanism understoodomnireal-acceptancereal-acceptancegate-batteryprocess

    Order disturbance tests from the robust side to the fragile side with protection scaled to sim-measured asymmetry, align and log frame conventions before testing, and treat cross-domain disturbance counts as qualitative evidence only.

    Symptom

    Hand-push testing on hardware risked falls on a side sim had already flagged as fragile, and push counts invited apples-to-oranges comparison with sim numbers.

    Context

    Sim chirality was explicit: descendants were far more fragile in -y (fric-3000@kd1.2: +6 N*s survived 15/20 vs -6 N*s only 3-9/20) while the s1e control was perfectly symmetric (40/40). The protocol therefore: push the positive direction first, keep a spotter for the negative side; before any push, record which real-robot side corresponds to sim's +y in the log ("上机前对一次坐标"); and - citing the chaos lesson ("混沌课文") - real push results are used only as qualitative corroboration, never compared numerically with sim survival counts across machines.

    Change

    Push testing became a scripted, chirality-aware protocol with frame alignment as a logged precondition and an explicit epistemic limit on cross-domain count comparison.

    Outcome

    The fragile side was tested with protection informed by sim's quantified asymmetry; logs stayed interpretable because the frame correspondence was recorded before the first push.

    Mechanism

    Disturbance-response chirality is a real, quantifiable lineage property, so test order should follow measured fragility; and perturbation outcomes are chaotic in the details (divergent trajectories from tiny differences), so counts do not transfer across domains even when qualitative rankings do.

    Applies when

    • planning push/disturbance tests on hardware
    • sim shows directional asymmetry in disturbance survival
    • someone proposes comparing real push counts to sim counts
    “先正向后负向, 负向留人扶 —— sim 手性明确: 后代在负 y 向显著更脆 (fric-3000 @kd1.2: +6 N·s 15/20 vs −6 N·s 3~9/20), 而 s1e@0.8 两向 40/40 完全对称。上机前对一次坐标 … 跨机不做二值结论 (混沌课文): 真机推力只作定性对照, 不与 sim 计数对比。”
    train/REAL_RUN_S2.md § 3. 抗推 (可选, 人手推; 做则按此协议)
  • Before training a one-leg stand, the accounts and a probe showed the default gains could not hold it at all - kp 20 needs 0.39 rad of error to carry the static roll moment, more than the whole adduction range - so per-joint gains came first, and thermal limits set the session lengthsingle-support-gain-authority-probe
    Mechanism understoodonelegplant-calibrationactuator-modelingplant-calibrationhardware

    Before training a posture that loads one joint statically, compute the steady tracking error load/kp and the series stiffness against m*g*h, and prove with a simple hand-written controller that the posture can be held under the deployment gains - change the gains first if it cannot; then size session length from the thermal account.

    Symptom

    The one-leg line (standing on one foot, the other folded back, no hopping) had to decide whether the existing gain profile could hold single support before any reward was designed.

    Context

    Hardware accounts (9.792 kg, COM 0.234 m high, 170 x 80 mm feet, legs 80% of the mass): moving the COM over one foot needs 107 mm of shift and the 20 deg hip-roll adduction range gives 131 mm - geometrically enough. The static frontal moment is 7.8-9 N*m, within RS02's 17 N*m - torque is enough. But at kp 20 carrying 7.8 N*m needs 0.39 rad of tracking error, more than the entire adduction range, and the real robot had already shown it: commanded +0.17, actual -0.04 (0.21 rad droop) under load, 0.0008 rad hanging - load, not the motor. A probe (probe_oneleg.py) then showed open-loop PD cannot hold single support on physics grounds, so the criterion became "an equilibrium exists and a hand-written 4-gain COM feedback can hold it": single-support roll stiffness is hip and ankle in series and must exceed m*g*h_com = 22.5 N*m/rad; ankle kp 12 in series with hip kp 80 gives only 10.4 (open loop 16/16 fell), ankle 60 with hip 80 gives 34.3 (52% margin).

    Change

    A per-joint gain profile (rl_oneleg: hip_roll kp 80, ankle_roll kp 60, the rest as rl_default) - which needed per-joint gain support in robot.yaml, the bridge, deploy and the trainer's actuator groups - decided before training. Thermal account: single support makes hip_roll the dominant heat load (about 7.8 N*m against a 7 N*m continuous rating), so acceptance and demos run in segments of at most 60 s with a temperature check.

    Outcome

    Under rl_oneleg the hand-written feedback held six cells cleanly for 6 s (hip_roll steady torque 2.1-3.4 N*m, half the thermal budget); under rl_default the same feedback on the same cells fell 0/4. The trained V0 policy then passed its 40-cell acceptance.

    Mechanism

    With PD position control, the steady error needed to carry a static load is load/kp; when that error exceeds the joint's range the posture is unreachable whatever the policy does, and series compliance between joints lowers the effective stiffness below the gravity stiffness that single support demands.

    Applies when

    • single-support, crouched or one-arm-load postures on PD actuators
    • a joint "droops" under load on hardware but tracks well when hanging
    • deciding whether a new skill needs its own gain profile
    “但 kp=20 时撑住 7.8 N·m 需要 **0.39 rad 跟踪误差 > 整个内收行程**。真机已实测: 命令 +0.17 实际 −0.04(droop 0.21 rad),悬挂时 0.0008 rad——是负载不是电机。 … 单支撑滚转是 hip/ankle **串联**刚度,必须 > m·g·h_com = 22.5 N·m/rad;ankle kp12 串 hip80 只有 10.4(开环 16/16 全摔),60 串 80 = 34.3(裕 52%) … **rl_default 同反馈同格 0/4 全摔**(增益档必要性对照)”
    git:Lucen V2@origin/oneleg-line:train/ONELEG_V0_SPEC.md § §1-1 单脚站: 几何可行,卡点是 hip_roll 增益权限 / §2 A 线增益 / §5 probe 定谳
  • The get-up kept getting faster because standing earlier paid more every step - lowering torque authority barely slowed it, and only zeroing the standing income for the first 3 s moved the pace into the design bandper-step-income-drives-speed-time-gate
    Mechanism understoodrecoveryreward-shapingreward-shapingcurriculum

    When a skill is too fast, find the term that pays for finishing early and gate that income by time; keep the "get into position" term ungated so the policy does not learn to wait, use a ramp instead of a cliff, and confirm with a paired same-level experiment that the drift is motivational before changing it.

    Symptom

    The user judged the get-up too fast (Isaac medians about 0.7-1.6 s) and suspected path dependence: the policy seemed to get faster the longer it trained.

    Context

    Lowering the beta authority 0.40 -> 0.30 cut impact but moved supine only 1.70 -> 2.00 s: coordination-limited, not torque-limited. A paired experiment inside one beta level (checkpoint 15,600 vs 18,499, +2,900 iterations, same ruler) measured the drift: get-up medians -7 to -10%. The spec concluded the motive, not the path, was the cause - per-step standing income pays for every early step, and any lineage (even one from scratch) races toward the fastest solution inside its constraints.

    Change

    V2.5: the standing income (base_height, stand_pose, still, feet_on_ground) multiplied by w(t) = clamp(t/3 s, 0, 1); upright deliberately NOT gated, so righting and sitting up early still pay and the policy is not taught to lie flat and wait; a ramp, not a step. V2.5b: zero before t0 = 3 s, then a 1 s ramp.

    Outcome

    V2.5: Isaac 100%, get-up +17-43% slower, MuJoCo 100/100/98/100% (the best cross-simulator reading yet), still short of the 3.5-4.5 s design band - a linear ramp only discounts early income. V2.5b: MuJoCo supine 2.04 -> 4.10 s and prone 3.18 -> 4.04 s, inside the band; the Isaac pace barely moved (a lineage habit on a gradient-free plateau). Later the zero gate proved harmful when trained from scratch (curriculum-history-is-part-of-the-product) and in the V3.1 lineage (time-gate-vs-wide-stance-retire-the-fix).

    Mechanism

    Constraints on authority or velocity change how the fastest solution looks; the time structure of the task income decides how fast the fastest solution is.

    Applies when

    • a policy is faster or more aggressive than wanted and constraints do not slow it
    • progress-style rewards pay every step spent at the goal
    • performance drifts faster with more training at fixed settings
    “**V2.5 机制(唯一)**:站立收入(base_height/stand_pose/still/feet_on_ground) 乘时间斜坡 w(t)=clamp(t/T_gate,0,1),T_gate=3.0 s;**upright 刻意不门控** (翻正/坐直早期照常拿钱,防"躺平等门开" … **用户假设量化 证实:逐步计酬动机在 β 包络内持续压缩时间,约束挡不住动机 —— V2.5 动机层 修法为正解。**”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §39 V2.5 预注册 / §39 补 配对实验
  • The smoke watcher panicked at the wrong operating point and its score goes blind when gates saturate - treat it as a survival sentinel, not a judgesmoke-watcher-operating-point
    Replicatedomnisim-evalmeasurementprocessgate-battery

    Configure every automated evaluator at the lineage's declared deployment operating point, give it graded metrics that cannot saturate, and until then scope its authority to catastrophe-detection - never let a mis-configured watcher stop or rank a rung on its own.

    Symptom

    Two watcher misfires in one ladder: (1) during the friction rung the watcher (evaluating at kd 1.0) reported panic-level 1/3 survival from iter 3300 - falsified by the official kd 1.2 scan, because the lineage's design operating point was kd 1.2 and the watcher lacked the --kd-scale passthrough; (2) during the PD rung the watcher's early-stop score froze at iter 1050 despite ongoing drift improvements, because with all eight gates passing (constant 0/3 failures) the score has no gradient left - "八门全过恒 0/3 时 score 对漂移改善盲, s1f 课文三现".

    Context

    Both are the same category: the in-training smoke loop is an instrument with its own configuration (operating point, score design), and its verdicts are only as aligned as that configuration. The booked doctrine: "冒烟只当存活哨兵" - until the watcher evaluates at the deployment operating point with graded metrics, its role is detecting catastrophes, not ranking checkpoints; ranking belongs to the full battery at the design operating point (and the watcher's scoring was separately patched to weight survival 3x so recoveries during hard phases are not early-stopped away).

    Change

    Watcher debt booked (--kd-scale passthrough); score saturation acknowledged with graded columns planned; selection authority kept with 20-seed batteries at the declared operating point.

    Outcome

    A false panic did not abort a rung that was actually passing at its design point; a frozen score did not hide real drift gains; the instrument's authority was scoped to what its configuration can actually see.

    Mechanism

    An evaluator is itself configured (gain profile, delay, metrics); evaluating a policy away from its design operating point measures a counterfactual robot, and bounded scores saturate once binary gates pass, losing all sensitivity. Instruments need the same operating-point discipline as deployments and graded outputs to retain gradient.

    Applies when

    • an automated smoke loop contradicts the official battery
    • early-stop scores freeze while graded metrics still improve
    • lineages with non-default deployment gain/delay profiles
    “watcher (kd1.0 口径) 3300 起 1/3 恐慌被 kd1.2 正式扫描证伪为考纲外假象 —— 工作点评测口径教训: watch_ckpt 缺 --kd-scale 透传 (待补), 冒烟只当存活哨兵。… watcher score 饱和误停 @1050(八门全过恒 0/3 时 score 对漂移改善盲, s1f 课文三现)”
    train/README.md § omni_s2e_fric (watcher 恐慌被证伪) / omni_s2e_pd (500 臂)
  • A joint-velocity penalty meant to slow the get-up cut joint speed 16% and left the get-up time unchanged - the knob never moved the variable, so the idea it was meant to test stayed untesteddof-vel-penalty-is-not-a-pacing-knob
    Mechanism understoodrecoveryreward-shapingreward-shapingattribution

    Before reading a result as a test of an idea, check that the knob actually moved the independent variable; velocity regularizers smooth a schedule they do not set, and a schedule driven by per-step task income moves only when that income's time structure does.

    Symptom

    The get-up took 0.6-0.9 s in Isaac with large torque demand; the user proposed getting up more slowly so less torque would be needed.

    Context

    The idea had support in the accounts: the acceptance bound is an upper bound of 5 s (5-8x margin), the quasi-static squat path peaks at 25% of the limits, and rolling over needs no momentum. R3.2 raised dof_vel from -1e-3 to -5e-3 as the single variable.

    Change

    dof_vel -1e-3 -> -5e-3 (child-run from R3.1).

    Outcome

    Get-up medians moved +0.02-0.04 s (noise); raw joint velocity -16%; torque demand median got worse (hip_pitch 46-48% -> 63-67%) as the new term competed with torque_headroom on the same joints; MuJoCo 98 -> 96%. Verdict FAIL on the knob, not on the idea, and the rung was not adopted. When pace was later attacked through the income's time structure (V2.5/V2.5b), the MuJoCo get-up moved into the 3.5-4.5 s design band.

    Mechanism

    The pace was set by base_height_progress paying for every step spent high (stand earlier, earn more); a velocity regularizer only smooths motion along the same schedule and does not change when the robot stands up.

    Applies when

    • trying to make a skill slower or gentler with smoothness penalties
    • an experiment's primary metric did not move and a verdict is being written
    • two penalties act on the same joints
    “**关键判读:`dof_vel` 罚只把关节速度压了 16%,而起身用时一点没变。** 也就是说**这一级根本没有把"慢下来"这个自变量推动起来** —— 所以它**不构成对 用户假说的检验** … 起身节奏由 `base_height_progress` 的逐步计酬决定(早站起来就多 拿),速度正则只在同一条时间轨迹上把动作抹匀,不改变何时站起来。”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §25 R3.2(dof_vel −1e-3→−5e-3,慢一点起身)
  • Set torque limits per joint from measured gait peaks - a uniform percentage is the wrong shape, and training must use the deployed numberstorque-limit-shape-by-measured-peaks
    Mechanism understoodwalkactuator-modelingactuator-modelinghardwareplant-calibration

    Measure per-joint torque peaks in the actual gait and set each limit as measured-peak x margin capped at rating; then propagate the same numbers into training and add an automated deploy-time consistency check - never derate by a uniform percentage, never let training assume torque deployment will not grant.

    Symptom

    A uniform 50% torque derating (18/8.5/7) had piled safety margin on the joints that never use it while cutting the busiest joint below half its measured demand.

    Context

    Per-joint gait peaks were measured (walk_v5 at cmd 0.3/0.6): RS06 (hip_pitch/knee) uses 5.5-5.9 N*m = 15-16% of its 36 N*m rating - cutting it to 12 is a free safety win; RS02's ankle_pitch runs at 16.2 N*m = 95% of its 17 N*m rating - "它是速度的硬件瓶颈", no room to cut; RS00 measured 36-44%, capped at 11. The resulting shape 12/17/11 replaced the uniform percentage. Sweeps across several limit sets (rated / 50% / 14-17-11 / 12-17-11) produced identical speed, lift, and landing force - within this range the limits do not shape the gait; what matters is consistency: "关键是训练和硬件必须是同一个数", because the exporter fills effort_limit from tau_limit, and a policy trained at rated 36/17/14 "会假设有三倍力矩可用" while deployed at 12/17/11 (exactly the v5 cross-generation inconsistency later suspected in its wild kicking).

    Change

    robot.yaml tau_limit set to the measured-shape 12/17/11, firmware written to match, and train/isaac_values.py regenerated so training sees the same limits; the deploy tool self-checks limits against robot.yaml on every run.

    Outcome

    Free safety margin captured where demand is low, the real bottleneck joint left at rating, and the train/deploy torque worlds unified with an automated consistency check.

    Mechanism

    Torque demand is grossly unequal across joints in a gait (15% vs 95% of rating here); a uniform percentage misallocates the safety budget by construction. And since the trainer treats effort_limit as a plant truth, any train/deploy mismatch is an invisible plant gap of exactly the mismatch ratio.

    Applies when

    • choosing safety torque limits for a legged platform
    • training-vs-deployment actuator limit audit
    • one joint runs near rating while others idle
    “曾用统一 50%(18/8.5/7)是错的形状: 把余量堆在用不到的 RS06 上, 却把 ankle_pitch 砍到需求的 52%。… RS02 在 0.6 m/s 已用到额定 95%, 它是速度的硬件瓶颈 … 实测多组限幅 … 完全一致 —— 限幅在这个范围对步态零影响, 关键是训练和硬件必须是同一个数。… 若训练仍按额定 36/17/14, 学出的策略会假设有三倍力矩可用。”
    train/WALK_V6_MINIMAL.md § 3. 训练侧必须同步的一件事
  • The walking lines' safety setting, power-scale 0.8, broke the recovery policy's full-range contract - it cut the ends of the joint travel (4/50 could not get up) and left the torque spikes untouched; a kp x 0.9 gain profile inside the trained kp band did the jobpower-derating-cuts-full-range-contract
    Observed oncerecoveryreal-deployreal-acceptanceactuator-modelingcontract-freeze

    A deployment derating knob means something only relative to the action contract: before reusing a line's "safe setting" on a new skill, check what it does to that skill's reachable range and to the term that makes the spikes, prefer a gain change inside the band the policy was randomized over, verify it in simulation, and re-decide when the contract changes.

    Symptom

    After the violent first real get-up (2026-08-09), the recovery policy needed a gentler setting for its next hardware test, and the walking and omni lines' standard derating - deploying at power-scale 0.8 - was the obvious candidate.

    Context

    The V0 recovery contract maps actions to absolute targets over the full joint range: a = +/-1 lands exactly on the URDF limits, and standing puts the knee at the clip. Candidates were compared on R3.1 in MuJoCo (5 categories x 10 seeds) on 2026-08-10 before any hardware time was spent.

    Change

    A new gain profile, rl_kp090 (kp x 0.9, kd unchanged), recorded in robot.yaml as the recovery hardware-test setting, with power-scale 0.8 explicitly banned for recovery.

    Outcome

    kp x 0.9: 48/50 got up; median torque demand on hip_pitch/knee fell from 120-125% to 100-104% of the deployment limit; leg-leg contact frames 2,152 -> 1,095; the change sits inside the +/-10% kp randomization the policy trained with. power-scale 0.8: 4/50 could not get up, because under the full-range contract it removes the ends of the travel (the deep squat's tucked legs, the straight standing knee), and the torque spikes (kp x error) did not fall at all. When the line moved to the beta-anchored contract, rl_kp090 was declared a V0-era choice that does not fit (beta is calibrated at kp 30) and deployment returned to rl_default; the deploy switch applies power scaling to the walking side only.

    Mechanism

    A power scale multiplies the action, which under an absolute full-range mapping shrinks the reachable workspace instead of softening the actuator; the spikes come from the proportional term on large errors, which only a gain change reduces - and a gain change inside the trained randomization band stays in distribution.

    Conflicts

    The undated operator runbook still carries an R3.1 "B comparison" command at power-scale 0.8 beside the rl_default baseline; the sources do not say whether it was written before the ban or was ever run.

    Applies when

    • reusing a power, torque or action scale from one skill on another
    • a policy whose actions map to absolute targets over the full joint range
    • choosing a gentler setting for a first or second hardware trial
    “kp×0.9 / kd 不动 —— recovery_r3_1 成功 48/50, τ 需求中位 hip_pitch/knee 120~125% -> 100~104% 部署限, 腿-腿接触 2152 -> 1095 帧; ±10% 在训练 kp DR 带内. ⚠️ power-scale 0.8 对 recovery **禁用**: 全 ROM 契约下 0.8 砍的是行程 端点 (深蹲收腿/站直够不到), 实测 4/50 起不来, 且尖峰 (kp·err) 一点不降 —— 它是 walk/omni 的安全档, 不是 recovery 的.”
    git:Lucen-recovery@origin/recovery:robot.yaml § gain_profiles 注释: recovery 真机测试安全档 (2026-08-10) / rl_kp090
  • Isaac splits Coulomb friction into static and dynamic columns - wiring only static means zero loss during motion, silently discarding the identified valuesim-api-friction-columns
    Mechanism understoodinfraplant-calibrationplant-calibrationactuator-modelingdomain-randomization

    When installing identified actuator parameters, map each measured quantity to the simulator's exact API column for the operative regime (dynamic for moving loss, viscous for damping), verify per joint after landing, and audit how randomization intervals fall on each column's nominal.

    Symptom

    The hardware-identified Coulomb friction (tau_c) was about to be installed into the trainer through the friction= field alone - which in Isaac 5 populates only STATIC friction, so during motion the joints would lose no torque at all: "只给 static 则运动中不损耗, 辨识的 τ_c 走路时等于没接" (the identified tau_c would effectively not be connected while walking).

    Context

    The v12 integration wired all three columns deliberately: armature= and friction= from the 2026-08-04 hardware identification, PLUS dynamic_friction= (Isaac 5 splits Coulomb into static/dynamic; the moving-loss column is dynamic) and viscous_friction= (= the measured joint damping 0.02, aligned to MJCF's damping). Each value was re-checked per joint after landing. A DR interaction was audited and booked rather than hidden: randomize_joint_parameters jitters ALL friction columns with ONE interval - the [-0.05, +0.10] band was calibrated against the Coulomb nominal, and landing on the viscous nominal 0.02 it becomes [0, 0.12], "偏宽但保守" (wide but conservative), accepted with the note that pre-viscous behavior was already [0, 0.10] on a base of 0.

    Change

    Measured actuator parameters installed across all applicable API columns (armature, static, dynamic, viscous), with the DR side effect on shared randomization intervals audited and recorded.

    Outcome

    The first generation where the identified plant actually acts during motion in the trainer; the silent-column failure mode documented before it cost a training run.

    Mechanism

    Physics engines decompose "friction" differently (single coefficient vs static/dynamic/viscous columns); a measured parameter is only installed when it reaches the column the solver reads in the regime that matters (motion, not stiction). Randomizers that share one interval across columns rescale the band by each column's nominal - a hidden unit change.

    Applies when

    • installing identified friction/armature into any trainer
    • porting plant parameters between simulators or engine versions
    • joint losses in sim do not match bench measurements during motion
    “并额外传 dynamic_friction=(Isaac 5 把库仑拆 static/dynamic 两列,只给 static 则运动中不损耗,辨识的 τ_c 走路时等于没接)与 viscous_friction=(= joint_damping 0.02,对齐 MJCF damping)。… randomize_joint_parameters 用同一个 friction 区间抖三列, [-0.05,+0.10] 是按库仑标称标的,落到粘滞标称 0.02 上成了 [0,0.12]”
    train/WALK_V12_SPEC.md § 7. 核查单 (Isaac 接 V.ACTUATORS 新字段)
  • The 1.5 Hz step-frequency gate was retracted - the author had misread his own actuator data, and the limit fought pendulum dynamicsgate-threshold-retracted-frequency
    Mechanism understoodwalkgate-batterygate-batteryactuator-modelingprocess

    Every gate threshold must cite its measurement and survive a first-principles sanity check; when a gate keeps failing otherwise healthy behavior, re-derive the threshold from the raw data before enforcing it again - and retract wrong gates in writing.

    Symptom

    An acceptance criterion "step frequency <= 1.5 Hz" kept failing healthy policies (walk_v4 at 2.33 Hz), and an earlier attempt to force slower stepping (v3) had killed stepping altogether.

    Context

    The threshold had been derived from the author's own actuator frequency-response measurements - but re-reading the raw table showed the misread: amplitude ratio at 2.0 Hz is 0.88 (knee) / 0.83 (ankle), acceptable; the genuinely bad point was walk_v2's 3.8 Hz at 0.58. Mechanism check agreed: the leg as a compound pendulum (L ~ 0.30 m) has a natural frequency ~1.1 Hz, swing half-period 0.45 s - the observed 2.1-2.4 Hz sits near where the leg wants to swing, and forcing 1.5 Hz "是跟摆动动力学对着干" (fights the swing dynamics). The frequency definition itself was pinned by two independent methods (contact-event counting 2.39 Hz vs FFT 2.33 Hz, agreeing): reported numbers are cycle frequency = steps per leg per second.

    Change

    Gate retracted in writing: "步频 ≤1.5 Hz 应删除或放宽到 ≤2.5 Hz"; frequency definition standardized before entering any config.

    Outcome

    walk_v4/v6's 2.1-2.4 Hz reclassified from disease to normal; the v3 failure got its probable explanation (suppressing stepping to meet a wrong gate).

    Mechanism

    A gate is only as good as the measurement and the reading behind it; thresholds inherited from a misread plot become invisible design constraints that later training obeys at real cost. Cross-checking a threshold against first-principles dynamics (pendulum frequency) is a cheap way to catch such misreads.

    Applies when

    • an acceptance threshold repeatedly fails policies that look healthy
    • thresholds were set from a single person's reading of raw data
    • a forced compliance with a gate degrades the behavior it guards
    “我当初依据自己测的执行器频响定的,但看错了区间。… 2.0~2.4 Hz 的幅值比 0.83~0.88 是可接受的;真正不行的是 walk_v2 的 3.8 Hz。… 腿按复摆算(L≈0.30 m)自然频率约 1.1 Hz … 把它压到 1.5 Hz 是跟摆动动力学对着干(walk_v3 把迈步压没了,可能正是这个原因)。”
    train/WALK_DIAGNOSIS.md § ② 撤回"步频 ≤1.5 Hz"这条验收标准 —— 是我定错了
  • A real-robot verdict is (policy x deployment stack) - when the stack changes materially, old verdicts expirestale-verdicts-under-old-stack
    Mechanism understoodwalkreal-acceptancereal-acceptanceattributionprocess

    Date every hardware verdict with the deployment-stack version it was measured under; after any material stack change, re-test before trusting old condemnations or old praises - with the interpretation of each possible result written down first.

    Symptom

    walk_v5 stood condemned as "kicks wildly" and walk_v6 as "cannot walk unassisted" - but those verdicts were issued under an earlier deployment stack (--heading did not exist yet, several fixes had just landed); only v7 had ever run under the current unified stack.

    Context

    New sim evidence sharpened the doubt: a same-harness four-version sweep showed v6 was the HEALTHIEST archive at the real operating point (cmd 0.15: dominant frequency locked at 2.50, steps 35:35 perfectly symmetric, foot distance 203/190 mm best of four, mean tilt 4.2 deg, saturation 15%). A full re-test under the unified stack was scheduled with per-version questions and a pre-filled interpretation table ("判读表(预填假设,回来对号)"): e.g. v6 walks + frequency ~2.5 -> old verdict was the stack's fault, v6 becomes the comparison champion; v6 walks but at ~1.25 -> period-doubling on hardware = confirmed plant gap, actuator fitting promoted to mainline; v5 no longer kicks -> the kicking was an old-stack artifact.

    Change

    All four versions re-queued on hardware under one stack (same torque limits, slew profile, heading loop, logging), with the version-specific legacy profile pinned; verdicts held provisional until re-issued.

    Outcome

    The re-test design separated policy properties from stack artifacts before any policy was permanently written off - and turned each outcome into a specific conclusion via the pre-filled table.

    Mechanism

    A deployed behavior is produced by the policy plus everything between it and the motors (heading loop, slew limits, torque caps, clock); verdicts implicitly condition on that whole stack. Fixing the stack invalidates the conditioning, so old failures may be stack artifacts and old successes may not survive either.

    Applies when

    • deployment tooling (limits, filters, loops) changed since a policy was last judged
    • deciding which historical policy is the rightful baseline
    • a sim sweep contradicts an old hardware verdict
    “只有 v7 在完整的今日部署栈下上过真机 … v5"左右乱踢"、v6"未能自主"的判决全部来自更早的栈(--heading 尚不存在, 部分修复刚落地)——判决已过期。且 2026-08-02 四代同机仿真横测翻出了新证据:v6 在真机工况(cmd 0.15)下是四代里最健康的仿真档案”
    train/REAL_SWEEP_V5_V8.md § 0. 为什么重测
  • The deploy-side walk/recovery switch - into recovery at tilt > 65 deg held 0.3 s, back at tilt < 15 deg with angular rate < 1 rad/s and straight knees held 1 s, a 15 s timeout, last action cleared both ways - and the handoff steps the design required are only partly implementedwalk-recovery-fsm-handoff
    Observed oncerecoveryreal-deployreal-acceptancecontract-freezeprocess

    Specify a deploy-time controller switch as hysteretic, time-filtered predicates the robot can measure (proxy what it cannot, e.g. straight knees for height), a timeout that ends in a safe stop, and a complete handoff (history, clock, last action, command ramp) - then test that the code performs every handoff step, because the design document is not the implementation.

    Symptom

    With a recovery policy and a locomotion policy as separate networks, the robot needs a switch: when is it "fallen", when is it "up", and what state must be reset so the next policy does not act on the previous one's history.

    Context

    The 08-09 design: enter recovery when fallen (tilt > 55 deg or height < 0.60 x 0.384 m) for 150 ms, leave for a stand-hold when upright (tilt < 12 deg, height > 0.85 x 0.384 m, feet steady, |omega| < 0.8) for 400 ms - wide entry, strict exit, hysteresis - then a mandatory handoff trio before walking resumes (reset the walking policy's observation history, restart its phase clock at 0, clear its previous action and latency buffer) and a command ramp instead of a jump. The 08-14 implementation in deploy_policy (--recovery-policy): each policy under its own manifest contract (walk: nominal + scale; recovery: beta-anchored), the same rl_default gains, the tilt cutoff disabled; RECOVERY at tilt > 65 deg for 0.3 s; LOCO again at tilt < 15 deg and |omega| < 1 and knees straight (< 0.35 rad) for 1 s - the robot's computer has no height estimate, and straight knees stand in for height so a V3.0-style upright kneel cannot pass as standing; RECOVERY longer than 15 s ends in a safe stop; last_action cleared on both switches; command forced to 0 during RECOVERY; power scaling applies to LOCO only.

    Change

    An open account was written down with it: the recovery end state (0.355 m stance, hip yaw -/+27 deg) is outside the walking policy's training start distribution, so the first test must use stand / zero command as LOCO, and the long-term fix is to widen the walking policy's initial states rather than bend recovery's stance to suit walking.

    Outcome

    The spec records only a successful compile (py_compile); the hang test was left to be done on site. The operator runbook carries the three-step procedure (hang with stand as LOCO, mat and push, then omni walk as LOCO) but no outcome.

    Mechanism

    Two policies trained separately each assume their own history, clock and last action; a switch that carries any of them across feeds the next policy a state it never saw - the design called this "the walking policy seeing a ghost history".

    Conflicts

    The 08-09 design requires resetting history, clock and previous action plus a command ramp; the 08-14 implementation records last_action clearing and a zero command during recovery; the one-leg spec of 2026-09-14 lists the handoff hygiene as specified but not implemented - reset_history() is called by nothing (a 215-dim policy would carry four frames of pre-fall history), the phase clock is not zeroed, and there is no command ramp back to LOCO. No hardware run of the FSM is recorded in either source.

    Applies when

    • switching between separately trained policies on hardware
    • a policy with history or phase observations is re-enabled mid-run
    • the robot lacks a sensor the switching criterion was designed around
    “**判据**:进 RECOVERY = 倾角 >65°(`--fall-tilt-deg`)持续 0.3 s;回 LOCO = §5 真机可测子集:倾角 <15° ∧ |ω|<1 ∧ **膝直 <0.35 rad(NX 无高度观测, 高度门用膝直代理 —— 防 V3.0 型"跪坐但直立"误判)** 持续 1 s (`--recover-hold`);RECOVERY 单次 >15 s(`--recovery-max-time`)安全停。 … **切换卫生**:两向切换 last_action 清零;RECOVERY 态 cmd 强制 0”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §50 FSM 双策略调度(2026-08-14,用户令):deploy_policy --recovery-policy
  • Training the final recipe from scratch in one run - every mechanism the lineage had accumulated - produced 0% and a seated robot; the order in which the lineage acquired those mechanisms was part of why it workedcurriculum-history-is-part-of-the-product
    Observed oncerecoverytraining-runcurriculumprocess

    A recipe that ends a lineage is not a recipe for a from-scratch run: consolidate it as ordered curriculum phases matching how the lineage acquired its mechanisms, check that every curriculum criterion is reachable from the starting policy, and read the run's raw term values, not the total reward, before calling it green.

    Symptom

    V3.0 trained the lineage's whole final recipe from scratch in one 9,000 iteration run - full beta curriculum, prone-conditioned pull assist, friction DR, the 3 s zero gate on standing income, flat_feet - testing the proposition "the product is defined by its configuration, not by its training history". Training looked all green (reward 26.33, episode length 500, 100% time-outs).

    Context

    Read in raw units against v2_6c at the same weights, the green was a seated equilibrium: base_height 0.377 vs 0.640, stand_pose 0.205 vs 0.516, flat_feet 0.0000 (zero because it sits outside its height gate, not because the feet were flat). Acceptance: 0.0% in Isaac at the deployed authority, 0.0% on every MuJoCo friction level, and still 0.0% at the training-time authority (100% seated at 0.222 m, upright and still).

    Change

    The full stdout (316k lines) was read: the beta curriculum's criterion (standing share over 0.35) was met zero times, so beta never left the wide setting and the policy had no experience at the deployed authority; the pull curriculum was stuck on the same criterion. The lineage had escaped the seated basin with immediate income (V2.0-V2.2) and only then added the zero gate to cure rushing (V2.5); from scratch, the zero gate removed the early "stand fast, earn more" gradient needed to escape. Verdict "the curriculum history is part of the product", limited to n = 1. v2_6c stayed the product.

    Outcome

    V3.1 kept the order as explicit phases: P1 from scratch with immediate income (zero gate off) until the curricula advance, P2 adding the zero gate. P1b/P1c escaped the seated basin and passed; P2 was later judged net negative and dropped (time-gate-vs-wide-stance-retire-the-fix).

    Mechanism

    Mechanisms that refine a competent policy (time gates, tight authority) can delete the gradient a naive policy needs, and a curriculum whose advancement criterion the naive policy never meets freezes at its first level.

    Conflicts

    The spec limits the falsification to "this recipe + this curriculum criterion" (n = 1, no seed sweep, no criterion tuning). V3.1's phased run succeeding is consistent with the ordering reading but changed other terms too.

    Applies when

    • consolidating a long lineage of continuation fixes into one clean recipe
    • a from-scratch run with all mechanisms enabled plateaus early
    • curriculum state is not logged or never advances
    “命题:产物由配置定义,而非训练史定义。 … 训练 log(完整 stdout 316k 行)`[beta_anchor]` 仅初始 1 行,**达标 0 次** … V2.0~V2.2 靠**即时计酬**爬出坐姿盆地(§33),站立巩固后 V2.5 才装归零门 治"过快"(§39)。**课程史是产品的一部分。**”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §42 V3.0 判决(2026-08-11):从零单 run 全机制 FAIL 于坐姿盆地
  • A training-side rate limit anchored on the last commanded target is an integrator inside the balance loop - two unrelated lineages converged to the same 34-43% re-fall rate, a soft penalty could not fix it, and the bandwidth arithmetic said safety and standing could not coexistslew-anchor-is-an-integrator
    Mechanism understoodrecoverytraining-runactuator-modelingcontract-freezeattribution

    If you constrain actions in training, anchor the constraint on the measured state, not on the previous command - a limiter with memory adds lag inside the balance loop; and when two different lineages converge to the same failure rate, treat the cause as structural and stop adding soft penalties.

    Symptom

    With the rate limit moved into training (V1), policies either could not stand up or stood up and kept falling again: the stand oscillated, fell and climbed back, 34-43% of the time.

    Context

    V1.0-B (user decision: explore new postures from scratch, hard constraint in training): target <- prev + clip(target - prev, +/-S*dt) at the TIGHT rates, anchored on the last issued target like the bridge. Four runs: v1_0 from scratch 0.8% - every category righted under the limit, then knelt (the limit also damped the exploration that had escaped the seated basin in V0); v1_0c continued from R3.1 99.8% get-up but 36-43% re-fall and knee jitter 0.604 rad/s; v1_0p with a pull-assist curriculum (56 N -> 0, fully withdrawn) 39.1% unassisted, re-fall 34-42%; v1_0w with a windup-gap penalty 25.4%, re-fall 18-43%. Removing the limiter from v1_0p gave 0.0%: the policy had co-adapted with it.

    Change

    The rate-limit route was declared dead after four runs and the line was re-rooted on a beta-anchored action space (V2, user approval required).

    Outcome

    V2.0's first acceptance at full authority already showed re-falls of 0-1% (V1: 34-43%), the structural bet paying off before any tuning.

    Mechanism

    Anchored on the previous command, a saturated policy becomes a rate controller - one more integrator in the loop - and active balance through that lag oscillates, while a kneeling sit needs no active control and is stable. The arithmetic: kp 30 needs 0.4 rad of error for 12 N*m; at 4 rad/s that takes 0.1 s, half the pendulum time constant sqrt(0.38/9.8) ~ 0.2 s; keeping standing bandwidth needs S of at least ~8 rad/s, within 20% of the 10 rad/s velocity limit - no bound at all. Anchoring on the measured angle (q + beta*a) makes the full kp*beta authority available in one step, with no memory, and caps the impact at the same time.

    Applies when

    • adding rate limits, slew limits or target filters to a policy's action path
    • a policy stands but oscillates and re-falls after a constraint was added
    • different lineages or curricula land on the same failure signature
    “v1_0p(拉力课程):会站(prone 79.9%),再摔 34~42% —— **两条完全不同 血统、不同学习路径,收敛到同一失败率**。 … 动作饱和时它退化为 速率控制 = 环内多一个积分器;主动站姿平衡穿过该滞后必振荡(v1_0 的跪坐不需 主动控制,所以稳)。对照:**HoST 的 β 锚在当前实测 q,无记忆、无积分器**”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §31 结构病定案:slew 的目标锚 = 控制环里的积分器
  • Cross-simulator gate (Isaac Lab to MuJoCo) comes before any hardware attemptsim2sim-gate-before-sim2real
    Replicatedwalksim2sim-gatesim2simprocessgate-battery

    Gate every policy through a second simulator with an independently built plant before hardware; treat sim2sim failure as a contract or overfitting bug, and sim2real failure after a sim2sim pass as a plant/actuator gap.

    Symptom

    A policy that only ever ran in its training simulator carries untested dependencies on that simulator's solver, contact model, and defaults; the first place those dependencies surface should not be the real robot.

    Context

    Standing order of operations for the whole Lucen program, recorded as the opening line of the experience log: train in Isaac Lab, gate in MuJoCo, only then go to hardware. The MuJoCo side is the same plant used for evaluation batteries, so a sim2sim pass also validates the exported policy + contract (obs ordering, scales, defaults) outside the training stack.

    Change

    Pipeline rule adopted - every checkpoint must pass the MuJoCo evaluation battery (sim2sim) before it is considered for real deployment (sim2real).

    Outcome

    Used generation after generation as the cheap filter; hardware sessions only ever received policies that had already survived a second simulator.

    Mechanism

    Two simulators disagree exactly where a policy is overfit to simulator-specific artifacts (contact softness, integrator, default parameters, obs conventions); a cross-sim transfer catches contract bugs and solver overfitting at zero hardware risk, so real-robot failures that remain are attributable to genuine plant/actuator gaps.

    Applies when

    • planning the path from training to first hardware trial
    • exported policy behaves differently outside the training framework
    • triaging whether a real-robot failure is contract vs plant
    “先sim2sim - 从isaaclab 到mujoco / 再sim2real”
    Experience.md § opening lines (1-2)
  • The run policy never left the ground and fell in the second simulator from the frontal plane - its DR (gains and latency only) covered the actuator axis, not the frontal-plane contact and inertia disturbances the doubled stride amplified; "is DR on" is the wrong questionthin-dr-judged-by-channel-coverage
    Replicatedrundr-tuningdomain-randomizationsim2simattribution

    Judge a DR recipe by whether its randomized terms cover the channel where the skill can lose stability, not by whether DR is enabled; when a new skill lengthens single support or enlarges motion in one plane, add disturbances in the plane it destabilizes before training.

    Symptom

    run R1 (6,000 iterations, 78 min): no flight phase ever appeared, and every one of 13 checkpoints failed the eight-gate MuJoCo smoke. In Isaac: zero terminations in 6,000 iterations, 4.2 deg tilt. In MuJoCo at delay 2: 1/6 survived, falls within 1.9-6.2 s at 50.8-58.7 deg, the most saturated joints all roll joints.

    Context

    The run contract doubled sagittal travel (knee action scale 0.9, knee swing peak 1.14 rad) with a 0.60 s period and 0.40 duty - long single support - while roll/yaw scales were deliberately left at 0.5. DR copied the s1e recipe: kp/kd (0.9, 1.1) and latency on; mass, COM, joint friction and push all off; ground friction pinned at (1.0, 1.0). Flight was read two independent ways: Isaac's per-foot contact reward stayed 0.845-0.857, never above 0.87 - the arithmetic ceiling of a gait with zero flight - and 30 of 36 MuJoCo seeds had flight fraction exactly 0 (the nonzero six were all tumbling falls). Foot lift itself worked (46-59 mm against a 50 mm design point): the walk-era "not enough travel" failure did not recur.

    Change

    Verdict FAIL, with the pre-registered first knob (exploration noise 1.0 -> 1.2) explicitly rejected as aimed at a different axis. The lesson was generalized and applied at the next line's design review: the one-leg spec made push, body mass, base COM and friction DR mandatory for its permanent single support and banned the thin recipe.

    Outcome

    The run line did not continue past R1 in the sources. The one-leg V0 with the wider DR passed its friction-variant gate (mu 0.4 and 1.2) inside a 40/40 acceptance.

    Mechanism

    Randomizing gains and latency covers the actuator's axis; a skill whose failure lives in frontal-plane contact and inertia needs randomization on that channel (push, mass, COM, friction), or the trainer's exact plant becomes the only one the policy can stand on - the omni_s1 transfer trap a second time, this time with DR switched on.

    Applies when

    • a policy is flawless in the trainer and falls immediately in a second simulator
    • reusing a DR recipe from a skill with a different support pattern
    • failures concentrate on one axis (roll, yaw) the DR does not touch
    “**机理**: 矢状面行程翻倍 (膝摆动峰 1.14 rad) + T 0.60 + duty 0.40 的长单支撑, 把额状面扰动放大了一个量级; 而 roll/yaw 通道按 §3 **刻意没有放大** (仍 0.5), DR 又是 s1e 复刻的薄配方 (mass/COM/关节摩擦/push **四关全关**, 地面摩擦钉死 (1.0, 1.0))。 … 说明**薄 DR 的判据不能只看"有没有开 DR"**, 要看**开的那几项 是否覆盖失稳所在的通道** —— kp/kd 与延迟是执行器轴向的, 对额状面接触/惯性 扰动零覆盖。 … 0.87 正是「零腾空的走路步态」的天花板算术”
    git:Lucen V2@origin/run-line:train/README.md § run R1 FAIL (2026-08-09, run 21-30-30_run_r1): 腾空零, 但病根在额状面不在探索
  • When training fails repeatedly, inject the target behavior open-loop - stop tuning rewards for an unverified behavioropen-loop-probe-before-reward-tuning
    Mechanism understoodomniattributionattributionprocesscurriculum

    After two failed training attempts at a skill, stop training: demonstrate the behavior open-loop on the real plant/sim first, and only resume training once you hold a measured, safe, sign-verified target trajectory.

    Symptom

    Three sidewalk training rounds failed; hypotheses multiplied (exploration failure / wrong reference waveform / insufficient authority) with no way to pick between them by running more training.

    Context

    Instead of a fourth reward guess, the team wrote probe_side_ref.py: the candidate reference is injected open-loop on top of a frozen policy's output (bypassing PPO entirely), directly measuring "what happens if the robot literally does this waveform" - separating all three hypotheses in one experiment (5 seeds x 8 s per condition, several waveform families and gains). The probe immediately eliminated the authority hypothesis (full-amplitude execution, 5/5 survival) and localized the problem to the waveform/measurement side. The closing principle was written down after the saga: without a verified target behavior, tuning rewards is "在黑暗里试钥匙" (trying keys in the dark).

    Change

    Standing method: before opening another training rung on a failing skill, build an open-loop (or task-space) generator of the intended behavior, measure whether the physical system can express it and what it looks like - then train toward a verified, quantified target.

    Outcome

    The probe chain produced the verified waveform (reversed-sign triangle, half gain), quantified safe amplitude (tilt 8.2 deg at band top, foot distance clear of the wall), exposed the metric bug when probe and training disagreed, and ultimately supplied the feed-forward that made C4 pass in +100 iters.

    Mechanism

    Training couples exploration, reward design, and feasibility into one opaque outcome; open-loop injection cuts the loop and tests feasibility and waveform alone. A behavior demonstrated open-loop converts the remaining failure into a pure credit-assignment/reward question - and its measured trajectory becomes the reference itself.

    Applies when

    • repeated training failures on one skill with multiple live hypotheses
    • uncertainty whether the platform can physically express the behavior
    • a reference trajectory's shape/sign/amplitude is guessed, not measured
    “三轮 FAIL 之后不再猜,写 train/probe_side_ref.py 把参考开环注入到策略输出之上(绕过 PPO),直接量「照这个波形做会怎样」,一次分开三个假说:甲 探索 / 乙 波形 / 丙 权限。”
    train/C_LADDER_RUN.md § 3f. C4 真因定谳(开环探针) / 3k. 建议的下一步
  • Friction DR was demoted after a measurement (94% success at mu 0.4 with no friction randomization) and promoted again when the action contract changed and mu 0.4 fell to 76% - DR priorities belong to a plant and contract, not to a taskfriction-priority-re-measured-after-plant-change
    Observed oncerecoverydr-tuningdomain-randomizationsim2sim

    Re-measure transfer along the friction axis for every new action contract or plant, not once per task; a DR priority settled under one action parameterization does not carry to the next.

    Symptom

    Getting up is all scraping and pushing against the ground, and training pinned friction at 1.0, so friction looked like the first thing to randomize.

    Context

    The MuJoCo gate on R0.5 (5 categories x 10 seeds x 4 friction levels) measured 100/100/98/94% at mu 1.0/0.8/0.6/0.4: degradation showed first as time (prone 3.2 -> 5.3 s), not failure, so friction DR was demoted and the DR budget earmarked for mass/COM. After the switch to the beta-anchored action space, V2.2 read 90/94/90/76%: mu 0.4 was now the weak row.

    Change

    V2.3 (single variable): friction DR static (1.0, 1.0) -> (0.2, 2.0), dynamic (0.15, 1.6), the HiFAR range keeping the base dynamic/static ratio; restitution untouched. Continued from v2_2.

    Outcome

    Isaac nominal 99.8% (DR did not hurt the nominal plant); MuJoCo 98/98/96/92% - mu 0.4 76 -> 92%, mu 1.0 back to R3.1's 98% with bounded torque.

    Mechanism

    How much a policy leans on friction depends on how it moves; the spec records that the sensitivity rose after the action contract changed but does not establish why.

    Applies when

    • changing the action space, gains or authority of an existing skill
    • deciding which DR axis to spend the next rung on
    • an earlier sweep justified leaving an axis unrandomized
    “**μ 砍到 0.4(训练值的 40%)仍有 94%**,退化先体现在**用时**(prone 3.2→5.3 s) 而不是成败。μ≥0.8 完全无损。→ **§17 曾把"摩擦随机化提到 R4 第一项"当作优先 事项,这条实测把它降级了**”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §21 MuJoCo 复核门 ② 摩擦依赖
  • Real robot walked at half the sim clock for two generations - resolved by racing a reward-side and a plant-side evidence line, not by guessingperiod-doubling-evidence-race
    Observed oncewalkattributionattributionactuator-modelingplant-calibrationprocess

    For a hardware-only pathology, refuse to guess: pre-register one probe per side of the sim2real boundary (can the reward mechanism change it on hardware? can fitted plant parameters reproduce it in sim?) and let the first positive result direct the next version.

    Symptom

    The number-one sim2real gap: on hardware v6/v7 stepped at 1.23-1.32 Hz - almost exactly half the 2.50 Hz gait clock they were trained and simulated at; sim never reproduced it, two generations running.

    Context

    Instead of committing training budget to a guess, v8 pre-registered two mutually controlled evidence lines and kept the clock OUT of the training variables: (a) reward-side - if the v8 saturation fix revives joint_pos_ref (the term that pins the gait to the clock), re-run hardware and see whether frequency returns to 2.5 Hz (hypothesis: v7's frozen actions meant NO reward was pinning the gait to the clock, and the real plant - with armature and friction making high frequencies expensive - slid down to the leg's pendulum natural frequency ~1.1 Hz); (b) plant-side - record suspended joint data (fit_actuator), fit armature/friction, load the fitted values into sim2sim and see whether the 1.25 Hz reproduces IN SIM. Decision rule fixed in advance: "谁先给出阳性结果谁定 v9 的方向 (奖励侧 vs plant 侧)" - whichever line goes positive first sets the next version's direction.

    Change

    Period-doubling excluded from the v8 change set; both diagnostic lines scheduled in parallel as non-blocking work; frequency reported factually in acceptance with no pass/fail attached ("倍周期是否消失 不设判定,它是 §9 的关键证据").

    Outcome

    The gap was routed into a decisive-experiment structure rather than a speculative retrain; the plant-side line pointed at exactly the unmodeled armature/friction that were later measured and installed as the plant baseline. Resolution (era-2c full-plant retest): the family had TWO causes - v8's low-speed period-doubling vanished once measured armature+friction were installed (1.30 -> 2.50 Hz, bifurcation-edge machine sensitivity), while v7's stood untouched at 1.20 Hz (saturation-freeze-driven policy property) - both evidence lines paid off, one per case.

    Mechanism

    A behavior appearing only on hardware has candidate causes on both sides of the sim2real boundary; changing training to fix it tests only one side per expensive cycle. Two cheap parallel probes - one intervening on the reward mechanism, one making sim reproduce the real behavior - localize the cause to a side before any training money is spent, and sim-reproduction of a real pathology is itself the strongest form of plant validation.

    Applies when

    • a gait pathology appears on hardware but never in any simulator
    • deciding whether a sim2real gap is reward-side or plant-side
    • tempted to change the gait clock/reward to chase a hardware symptom
    “倍周期(真机 1.23~1.32 Hz ≈ 时钟一半,v6/v7 连续两代;sim 从不出现):两条证据线互为对照——(a)… 真机重跑看频率是否回 2.5 Hz(假说:v7 没有任何奖励把步态钉在时钟上,真机 plant 有 armature/摩擦、高频贵,自由滑落到复摆自然频率 ~1.1 Hz);(b)真机吊挂录 fit_actuator.py … 看能否在仿真里复现 1.25 Hz。谁先给出阳性结果谁定 v9 的方向。”
    train/WALK_V8_SPEC.md § 9. 平行线 (倍周期)
  • Model CAN polling skew - joint observations are 6-9 ms stale by read ordercan-timing-skew-modeling
    Observed oncewalkactuator-modelingactuator-modelingsim2simhardware

    If joints are read sequentially over a shared bus, reproduce the per-group observation staleness in sim (or randomize it over the measured range) - synchronous observations are a privileged fiction.

    Symptom

    Policies trained with synchronous joint observations degrade on hardware where motors are polled sequentially over CAN - hip data is already 6-9 ms old by the time ankle data arrives.

    Context

    Menlo's core sim2real finding on a leg platform of almost identical mass to Lucen's. CAN is a sequential bus: one poll cycle reads motors in a fixed order, so the observation vector mixes timestamps. Lucen runs 6:6 motors on a dual CAN split, so the problem transfers one-to-one.

    Change

    Explicitly model CAN timing skew in sim: give the joint groups different observation delays matching physical read order. Menlo went further - running real firmware in the loop with a motor simulator between MuJoCo and firmware injecting 0.4-2 ms uniformly distributed delay.

    Outcome

    Reported by the reference team as their core sim2real enabler on a same-scale platform; recorded in Lucen's experience log as directly applicable ("这个问题一模一样").

    Mechanism

    A policy exploits any cross-joint temporal coherence present in training observations; when hardware breaks that coherence per bus position, the learned feedback acts on inconsistent state estimates, injecting phase error exactly at the control bandwidth.

    Conflicts

    Second-hand episode: outcome numbers are the reference team's report, not a Lucen-run experiment; Lucen adopted the requirement but the corpus has no Lucen A/B of skew-on vs skew-off.

    Applies when

    • robot polls actuators sequentially over CAN/RS485 or similar shared bus
    • sim2real degradation appears as jitter or oscillation not seen in sim
    • designing the observation/delay model before a training run
    “电机走 CAN 是顺序轮询的,髋部电机的数据到踝部电机上报时已经陈旧了 6-9 ms,他们直接在仿真里显式建模了 CAN 时序偏斜,按读取顺序给三组关节不同的观测延迟。… 注入 0.4–2 ms 的均匀分布延迟。你们是 6:6 双 CAN 分总线,这个问题一模一样”
    Experience.md § 执行器 + 时序建模 (line 6)
  • The latency DR range must cover the measured deployment pipeline - 0-20 ms could not even reach the real 1-2 control stepslatency-dr-covers-measured-pipeline
    Mechanism understoodwalkactuator-modelingactuator-modelingdomain-randomizationhardware

    Measure end-to-end action latency in control steps on your own stack (including cross-process queue boundaries), set the DR range to cover it with margin, and never import a delay count without its control frequency.

    Symptom

    Action latency was randomized over 0-20 ms (0-1 control step at 50 Hz), but the measured deployment path is 1-2 steps: the deploy process writes the target, an independently running BusWorker picks it up on its NEXT cycle, plus CAN round-trip - the training range could not cover the robot's actual latency at all.

    Context

    Fix: widen action_latency_s to 0-0.06 (0-3 steps). The external reference's "uniform 6 steps" was explicitly NOT copied - that number depends on his unknown control frequency; locally, a sweep at 0/1/2/3 steps showed walk_v5 survives all with insensitive metrics, so 6 steps "在我们这里没有依据" (has no local basis). The range was set from the measured pipeline with margin, not from a foreign constant.

    Change

    action_latency_s (0, 0.02) -> (0, 0.06), justified by pipeline analysis (writer/worker cycle boundary + bus time) and bounded by the local latency sweep.

    Outcome

    The DR band now brackets the true deployment latency; the policy trains against the delay it will actually face instead of a fictional sub-step world.

    Mechanism

    Latency DR only immunizes against delays inside its support; a range below the physical pipeline guarantees an untrained distribution shift at deployment. The correct range comes from tracing the pipeline's worst case (queueing boundaries + transport), and foreign step-counts are meaningless without the control rate they were measured at.

    Applies when

    • setting or auditing action-delay randomization
    • deployment uses a separate bus/worker process from the policy loop
    • importing delay-modeling numbers from other projects
    “现行 0~20 ms = 0~1 个 50Hz 控制步, 而实测部署链路是 1~2 步(deploy 写 STATE.target 后, 独立跑的 BusWorker 下一轮才取走下发, 再加 CAN 往返)——现在的区间覆盖不到真机的实际延迟。… 不照抄参考来源的"统一 6 步": 那取决于他的控制频率(未知), 而我们扫过 0/1/2/3 步 … 6 步在我们这里没有依据。”
    train/WALK_V7_SPEC.md § ⑤ action_latency_s 0~0.02 → 0~0.06
  • The real robot's right-leg kicking was over-trained-delay times loop gain - irreducible pipeline latency is plant, model it fully from day onepipeline-latency-is-plant-not-dr
    Mechanism understoodomniactuator-modelingactuator-modelingreal-acceptanceattributionsim2sim

    Measure the end-to-end action pipeline delay and build it into the nominal plant and every acceptance gate from day one; treat power/scale deratings that "fix" oscillation as gain-reduction crutches flagging an unmodeled delay, and expect higher-feedback-gain policies to be MORE delay-fragile.

    Symptom

    On hardware, s1c/s1d at action scale 1.0 always kicked wildly with the right leg (s1c only ran as SOTA at power 0.8; s1d only at 0.7) - while sim showed nothing under default evaluation.

    Context

    Sim reproduced the incident item by item once the real pipeline delay was injected: s1d@1.0 with --delay 1 fell at 10.2 s, --delay 2 at 5.2 s; s1c@1.0 stressed (r_hip_roll saturation 5 -> 16%; "右脚" = the policy's chirality makes the right leg its high-gain leg); and the combos that worked on hardware (s1c@0.8+delay2, s1d@0.7+delay2) all survived in sim. Mechanism: the real pipeline is ~1-2 ticks (BusWorker next-cycle pickup + CAN round trip) but S1.1 trained only to 1 tick - "超训延迟 × 全环路增益 = 振荡;衰减 = 压环路增益换稳定" (delay beyond training x full loop gain = oscillation; the power derating had been buying stability by compressing loop gain). s1d was MORE fragile than s1c because its yaw 3-layer stack had learned higher feedback gain - higher gain, lower delay tolerance. Three changes: latency DR widened to cover reality; acceptance gates and smoke runs moved permanently to --delay 2 ("门必须在真机条件下预测 真机"); and the doctrine written twice-paid: "不可约的管线属性(延迟、 限速)不是'随机化选项',是 plant 本体,第一天就该全额建模" - S1's nominal-then-robust staging falsified by hardware for the second time. The later s1e hardware run at power 1.0 (no kicking, normal force) closed the loop: "0.8 = 旧代拐杖" - the derating had been a crutch for the under-modeled delay, not a real requirement.

    Change

    Latency modeled as plant from day one of any lineage (measured 1-2 ticks covered, bridge-layer rate limits likewise modeled by default); every gate and smoke evaluation issued under --delay 2.

    Outcome

    Kicking reproduced, explained, and eliminated in the s1e generation at full scale and full power; the deploy-side crutches (0.7/0.8) retired for the new lineage.

    Mechanism

    Feedback oscillation onset is a product of loop gain and phase lag; a policy trained below the real delay learns gains that sit past the real stability margin, and any output derating masks it by scaling gain down. Since pipeline delay is deterministic hardware property - not an uncertainty - it belongs in the nominal plant, and every evaluation must include it or the gate predicts a robot that does not exist.

    Applies when

    • hardware oscillation/kicking that sim only reproduces with added delay
    • a policy only runs on hardware at reduced power/scale
    • defining what belongs in the nominal plant vs the DR list
    “真实链路延迟 ~1~2 拍 … S1.1 只训到 1 拍——超训延迟 × 全环路增益 = 振荡;衰减 = 压环路增益换稳定。s1d 比 s1c 更脆 = yaw 三层栈学出更高反馈增益,增益越高延迟容忍越低。… 教训入账:S1「先标称后鲁棒」第二次被真机证伪——不可约的管线属性(延迟、限速)不是"随机化选项",是 plant 本体,第一天就该全额建模。”
    train/OMNI_V0_SPEC.md § 3. S1.4(真机右脚乱踢事故强制)
  • The recovery line's real-robot verdicts live in three places that disagree - the spec's "fairly stable, first real stand-up" for v2_6, an undated runbook note that only v3_1p1c works, and a first run whose details were never recordedwrite-hardware-verdicts-back
    Observed oncerecoveryreal-deployreal-acceptanceprocessattribution

    A hardware verdict is a dated entry in the authoritative ledger - policy file and stamp, gain profile, floor, battery, tries, log file, what was seen - written back the same day; a note in a command file is a pointer, not a verdict, and a newer verdict that contradicts an older one must say so.

    Symptom

    Asked "which recovery policy works on the real robot", the sources give different answers, and none of them carries the conditions of the test.

    Context

    08-09: the first real run was stopped as violent and dangerous; which ONNX, which gain profile and whether a log existed were marked "to be recorded" and never were. 08-11: v2_6 was "fairly stable", the line's first real get-up, with splits after standing; v2_5b's result and both CSVs were "to be reported". 08-14: v3_1p1c was stamped and pushed, with "the real first test still needs the user present"; the spec records no hardware result for it. The operator runbook (undated) puts above the v2_6 and v2_5b floor commands the note that none of the recovery policies below work, only recovery_v3_1p1c - a verdict never written back into the spec, with no date, floor, battery, number of tries or log attached.

    Change

    None recorded in the sources; this card records the gap.

    Outcome

    The line's authoritative record ends with v3_1p1c as the product awaiting its first real test, while the operator's note implies it is the only one that works and that v2_6 (recorded as a success) does not.

    Mechanism

    Verdicts given at the robot travel by word of mouth and command-file comments; without a record carrying the conditions, a later reader cannot tell a changed verdict from a changed floor, battery or stack.

    Conflicts

    §43 (2026-08-11) records v2_6 as the first successful real get-up ("fairly stable"); the undated runbook says every recovery policy except recovery_v3_1p1c does not work; §49 (2026-08-14) says v3_1p1c's first real test was still pending. The runbook's claim has no date and was never written back to the spec, so it cannot be ordered against §43.

    Applies when

    • choosing which policy to deploy from an operator's notes
    • a hardware session ends without a written result
    • two documents disagree about what worked on the robot
    “下面的recovery都不行 只有recovery_v3_1p1c.onnx”
    RL系统/FOLLOW THIS copy 2.md § #### Recovery Policy (operator runbook, undated)
  • Foot dragging is an attractor, not a low amplitude - and joint damping is the mode switch, adjustable at deploy timeswing-bistability-damping-switch
    Mechanism understoodomniattributionattributiondomain-randomizationactuator-modelingreal-acceptance

    When a quality metric is bimodal, stop treating it as an amplitude to be trained up: map the modes against initial conditions and plant parameters, find the parameter that switches basins, apply it first as a deployment lever, and only then bake it into the training distribution (as a plant-family shift, never as an execution-mapping change).

    Symptom

    s2e_pd-1400's swing height "median 12.1 mm" hid a perfect bimodal distribution: 20 seeds split into a drag mode (2.6-4.9 mm) and a step mode (19.3-24.0 mm) with NOT ONE seed in between - the median sat in the empty gap, and "swing debt -11 mm" really meant "50% probability of falling into the drag attractor".

    Context

    Two designed experiments closed the mechanism. Test A (nominal plant, 40 seeds): step 42% / drag 58% / middle 0 - at nominal gains, initial conditions alone pick the mode, both modes 100% survivable. Test B (fixed init, kp x kd grid): kd is the mode SWITCH - at kd 1.3 all surviving cells step (13-22 mm), at kd 0.7 nearly all drag (2.7-4.3), only at kd 1.0 does init get a vote; kp >= 1.2 is dangerous (5/6 falls). Global verification at kd x1.3 (20-seed, delay 2): survival 20/20 at ZERO cost, step share 42 -> 80%, swing median 12.1 -> 18.4 mm, slip record low 334, thicker tilt margin - costs: vx 85 -> 78%, saturation +5 pp. A Pareto sweep then priced the knob: step share 42/72/75/88/82/90 across kd 1.00-1.30 with a linear vx tax of -2.3 pp per 0.1 kd - the basin gain is fully collected at kd 1.20 ("1.30 是 over-damping 纯多付税"). Mechanism: low damping leaves a landing micro-oscillation / ground-slide channel the policy can exploit to drag; damping plugs the channel.

    Change

    Deployment lever adopted: kd-scale 1.20 (conservative 1.15) as the legitimate successor to the power-0.8 crutch ("前者削幅度保稳,后者堵 拖地通道换步态,且不牺牲存活"); training-side prescription: move the DR band to nominal-1.2 x (0.9,1.1) = [1.08,1.32], deleting the [0.7,1.0) drag-teaching zone - a contract-level change requiring digest re-baselining, gated on measuring the real robot's actual kd dispersion first.

    Outcome

    The kd surgery rung (s2e_kd) delivered basin 8 -> 11/20, slip 405 -> 331, vx 81 -> 85% with no out-of-band fragility (below-band check 20/20) - "拐杖烧进分布的正确姿势", explicitly contrasted with the failed s1g amplitude version: this one changes the plant family the policy has seen, that one changed the execution mapping the policy would have to relearn.

    Mechanism

    The gait's swing behavior is a bistable dynamical system whose basin boundaries are set by plant parameters; a policy trained across a kd band that includes the drag basin has learned to inhabit it. Shifting the deployed (and then trained) damping moves the system into the step basin without touching the policy - a plant-side fix for what looked like a training deficiency.

    Applies when

    • a gait quality metric splits into distinct modes across seeds
    • deciding between more training and a gain/damping change
    • converting a deployment crutch into a training-distribution change
    “20-seed 里拖地模式 2.6~4.9mm 与迈步模式 19.3~24.0mm 各半,中间一个不落 … kd 是模式开关——kd1.3 下 6/6 存活格全迈步 … kd0.7 下几乎全拖地 … swing 债的解(至少大半)在部署端阻尼档,不在训练端 … 机理:低阻尼下落脚微振荡/贴地滑给了策略顺势拖行的通道,加阻尼堵之。”
    train/README.md § swing 双稳态定性 + kd 部署杠杆 (2026-08-07, 用户设计 Test A/B)
  • After installing the measured plant, re-run all generations paired on old and new plant - identity metrics carry verdicts, physics metrics re-baselineplant-swap-invariants-vs-shifts
    Mechanism understoodwalksim2sim-gatesim2simplant-calibrationgate-batteryattribution

    Treat every plant upgrade as an era boundary: re-run the retained policy set paired (same seeds/flags) on both plants, carry forward only verdicts whose metrics proved plant-invariant, re-baseline the rest - and mine the systematic shifts as measurements of the old plant's biases.

    Symptom

    With the plant finally fully measured (weighed masses 9.792 kg, bench-identified armature, in-situ friction), no historical sim number was comparable to new runs - "历史 sim 数字跨纪元不可比" - and it was unknown which historical verdicts still held.

    Context

    The era-2c cross-test ran all seven walk generations on the complete plant under one harness (14/14 survived), then re-ran the same 14 configurations on the OLD plant retrieved from git, same flags and seeds, with a self-check (one historical record reproduced digit-for-digit). The split was clean. Policy-identity metrics moved essentially zero across the plant swap - dominant frequency (v7's period-doubling 1.20 -> 1.20), knee amplitude (9.9 -> 10.0), foot distance (+/-2 mm), saturation (100 -> 100, 0 -> 0) - so all seven cross-generation verdicts (freeze signature, saturation-line closure, knee-collapse location, slip-penalty accounting, N2 lineage, v6's balance, v11's triad) were re-confirmed on the honest plant. Plant-physics metrics shifted systematically with ordering preserved: slip down 10-25% (measured friction makes ground-twisting costlier), landing vertical velocity down 15-50% ("旧 plant 高估落地 凶度"第二次独立证实), landing force mixed (mass up 2.2% vs friction braking the swing - two effects fighting). Exactly ONE behavior-level change: v8's low-speed period-doubling vanished (1.30 -> 2.50, lift normalizing) - confirming it had been machine-dependent bifurcation-edge behavior that armature+friction push off the knife edge, while v7's period-doubling stood untouched: saturation-freeze-driven, a policy property, not a numerical accident.

    Change

    Era re-baselining protocol: after any plant upgrade, one paired same-seed sweep of all retained generations on old and new plant; verdicts keyed to identity metrics carry over, thresholds re-read against the new-plant table, and the differences themselves become plant-physics findings.

    Outcome

    Seven verdicts survived with evidence rather than assumption; two causes of the period-doubling family were separated with plant-side proof; and the sim's landing-violence overestimate was independently confirmed a second time.

    Mechanism

    A policy's structural properties (frequencies, amplitudes, frozen joints) are functions of its weights and survive plant changes; contact-mediated quantities are joint properties of policy and plant and shift when the plant becomes honest. Pairing seeds across plants isolates the plant's contribution exactly, so the sweep both validates history and measures what the old plant had been lying about.

    Applies when

    • installing measured masses/armature/friction into the sim
    • historical thresholds are cited across a plant change
    • a hardware-only behavior might be bifurcation-edge sensitivity
    “策略身份指标逐位不动:主频(v7 1.20→1.20)、膝摆 … 这些是策略属性,plant 换代携带无损,历史定论因此全部成立。… 唯一行为级变化:v8@0.15 的倍周期消失(主频 1.30→2.50…)——印证当时"分岔边缘、机器相关"的判定:armature+摩擦把 v8 推离刀锋;v7 的倍周期纹丝不动(1.20→1.20),它是饱和冻结驱动的深层属性,不是数值巧合。”
    train/README.md § 纪元 2c 全代同机横测 (2026-08-04): 完全体 plant 上历史结论全部存活
  • Record-high training reward hid a fully-failing DR subgroup - aggregate metrics average over draws, gates must test per conditionaggregate-metrics-mask-subgroup-failure
    Mechanism understoodomnitraining-rundomain-randomizationgate-batterycurriculum

    Never gate on metrics aggregated across DR draws: evaluate at fixed representative conditions (especially the deployment-critical stratum), and if a difficulty axis matters, ramp it on measured per-stratum success rather than sampling the full range from iteration zero.

    Symptom

    omni_s1e trained under constant-wide latency DR (0, 0.06 s) posted the lineage's highest-ever Isaac reward (129) - while the --delay 2 smoke evaluation showed 3/3 falls from iter 1500 onward, persisting to early stop; the usable checkpoint window shrank to iters 500-1000.

    Context

    Diagnosis written plainly: "聚合奖励掩盖重延迟尾部子群体失败" - the aggregated reward averages over latency draws, so the majority of light-delay environments can mask the total failure of the heavy-delay tail. The remedy for the training side was a survival-gated ratchet curriculum (survival_gated_latency): the sampling cap starts at 0.02 s and rises +0.01 only when a 4096-reset window's survival (time_out share) reaches >=90%, capped at 0.06, ratchet up-only - "增益与延迟耐受一起长,不升到策略撑不住的 地方" (gain and delay tolerance grow together; never raise past what the policy can hold). The detection side was already in place from the noise-crutch episode: the per-condition smoke curve, not the training reward, is the health readout.

    Change

    Latency exposure made curriculum-gated on measured subgroup survival instead of uniform-from-zero; per-condition (--delay 2) smoke evaluation kept as the authoritative curve; watcher scoring adjusted (survival weighted 3x) so recovery during hard phases is not early-stopped away.

    Outcome

    The failure mode was caught by the smoke curve within one generation; the follow-up redesign (deterministic staged latency) superseded the ratchet, but the aggregate-masking lesson held through both.

    Mechanism

    Expected-return training weights each DR draw by probability, so a subgroup can contribute bounded loss while being catastrophically failed; any scalar averaged over the randomization cannot distinguish "uniformly decent" from "great on easy draws, dead on hard ones". Only conditioning the evaluation on the stratum reveals the split, and curricula should raise difficulty on measured stratum success, not on schedule.

    Applies when

    • training reward hits records while a fixed-condition eval degrades
    • wide DR on an axis where deployment sits at one known value
    • designing curricula for difficulty axes (delay, push, terrain)
    “常量 latency DR (0,0.06) 从零训被证伪——Isaac reward 129 历代最高,但 --delay 2 冒烟 iter1500 起 3/3 全摔持续到早停(聚合奖励掩盖重延迟尾部子群体失败,可用窗口只剩 500/1000)。… 采样上限 0.02 起步 … ≥90% 才 +0.01s,0.06 封顶,棘轮只升不降。”
    train/OMNI_V0_SPEC.md § 3. S1.5(s1e 训练塌方复盘)
  • Cutting swing amplitude 40% raised yaw-momentum demand 53% - the falsified fix is recorded so nobody walks that road againamplitude-cut-falsified-yaw-fix
    Mechanism understoodwalksim-evalmeasurementattributionreward-shaping

    Test gait fixes against the quantity the ground must actually supply (torque/force rates vs friction ceilings), not against kinematic proxies; record falsified fixes with their mechanism so the search space shrinks permanently.

    Symptom

    Support-foot yaw slip stayed at ~223 deg (vs 225 deg) after walk_v6 cut joint swing amplitudes by ~40% (hip_pitch 20.6->10.4 deg, knee 31.3->18.8 deg) - the change built on the theory "smaller swing = less yaw momentum to dump into the ground".

    Context

    Direct measurement inverted the theory: yaw-momentum amplitude ROSE 16% (+/-0.1000 -> +/-0.1159) and its rate of change rose 53% (1.86 -> 2.84 N*m demanded from the ground), pinned exactly at the foot's supply ceiling (2.8-3.3 N*m at mu 0.6-0.7) - so slip could not drop. The extra demand lives in higher harmonics: v6's crisper foot placement (better clearance 34 mm, lower landing force) shortens the momentum- exchange window, concentrating the same exchange into less time. The verdict was written as a closed road: "下一轮不要再走这个方向". An honest residue was also booked: WHY amplitude down but momentum up 16% remained unresolved, with the named next step (per-rigid-body decomposition of H_z, since per-joint RMS sensitivity ignores phase correlations).

    Change

    The "reduce amplitude to reduce yaw momentum" lever was removed from the planning space; future yaw-slip work redirected toward the supply side (friction) and momentum-rate mechanics.

    Outcome

    Slip unchanged (225 -> 223 deg); the falsification and its mechanism became a permanent constraint on the fix search space.

    Mechanism

    Ground yaw torque demand scales with the rate of change of angular momentum, not its amplitude; kinematic amplitude cuts that also sharpen contact timing can raise dH/dt while lowering range. When demand exceeds the friction-limited supply ceiling, slip is set by the ceiling, so demand-side changes below the ceiling do nothing visible.

    Applies when

    • attacking foot slip or yaw drift via gait shape changes
    • a fix targets an amplitude while the constraint is a rate
    • documenting a failed intervention after a version comparison
    “walk_v6 | ±0.1159 (+16%) | 2.50 Hz | 2.84 N·m (+53%) … 脚的供给上限 2.8~3.3 N·m(μ 0.6~0.7)—— v6 正好顶在天花板上, 所以滑移一点没降。… 结论: "减小摆动幅度以降低偏航动量"这条被 v6 证伪 —— 砍 39% 幅度, 需求反升 53%。下一轮不要再走这个方向。”
    train/WALK_DIAGNOSIS.md § ② 未生效的机理: 减小摆动幅度反而让偏航需求上升

Next page