Skip to content

Training Coach

The coach reads a training run and returns a diagnosis, in-whitelist proposals and an experiment plan — and every claim cites one of the cards below. This is that corpus: 22 methodology rules distilled from a real sim2real programme, and 171 episode cards behind them, each with the sentence in the war history it came from.

Doctrine

A report may cite any of these as doctrine-N.

  1. doctrine-1Contract freeze and fingerprint discipline

    The policy I/O contract (observation layout, scales, history semantics, action pipeline) is frozen and fingerprinted; every exported policy is stamped and verified; contract changes ship as new versioned profiles that leave old artifacts bit-identical, and old policies run forever under their era's pinned profile.

    Case. The 215-dim omni contract was frozen with a three-machine digest; the one contract-level extension (lateral feed-forward) went in as a new `omni_ff` profile with the old profile provably untouched, and the contract checker caught two real wiring bugs before any training (`contract-freeze-and-checker`). A silently changed gait-clock default would have fed old policies a 25% slower clock - closed by pinned legacy profiles (`legacy-profile-pinning`). A stale derived USD forked plant mass 2.2% until an automated source-vs-derived instrument gated it (`derived-asset-staleness-check`). A gain profile is part of the closed loop a policy was trained in and belongs in its stamp; the recovery line's anchored authority was left out of its manifest and recorded as the gap not to repeat (`gain-profile-belongs-in-the-stamp`), and a second policy behind a deploy-side switch made the handoff state itself a contract (`recovery-two-policies-and-a-state-machine`, `walk-recovery-fsm-handoff`).

    Coach application. On any proposal touching obs/action semantics, defaults, or derived assets: demand the version/profile plan, the fingerprint update, and the checker extension in the same change; flag any old artifact that would run under new defaults.

    contract-freeze-and-checkerlegacy-profile-pinningderived-asset-staleness-checkgain-profile-belongs-in-the-stamprecovery-two-policies-and-a-state-machinewalk-recovery-fsm-handoff

  2. doctrine-2Attribution by resolved training params - never eval-override knobs

    Capability differences between lineages are explained only by digging each lineage's *resolved* training configuration and eliminating columns; evaluation-side override knobs (kd-scale, power-scale, cycle-time) act on the plant for *every* policy and may serve as deployment mitigations but never as explanations.

    Case. Low-friction robustness across 8 lineages x 3840 cells was traced to kd DR *bandwidth* - every lineage had ground friction pinned to (1.0,1.0), so "trained friction" could not be the axis; the parameter axis and the plant axis were explicitly separated after the first attribution conflated them (`kd-bandwidth-mu-law-attribution`). "Weak turning" on hardware was a power-scale plant effect, not a training gap (`deploy-knob-attribution-before-retraining`); slowing the deploy clock was out-of-distribution, not a feature (`cycle-time-override-is-ood`). The ground truth for what a run trained under is the logged per-run config, not the source tree (`resolved-config-is-source-of-truth`).

    Coach application. Whenever asked "why is lineage A better", require the resolved-param table first; kill zero-variance columns; refuse explanations phrased in eval-knob terms; when a knob helps, label it deployment mitigation.

    kd-bandwidth-mu-law-attributiondeploy-knob-attribution-before-retrainingcycle-time-override-is-oodresolved-config-is-source-of-truth

  3. doctrine-3PASS gates become constraints; FAIL gates become objectives

    Once a skill passes its gate, that gate converts into a standing regression constraint (budget <= 2/20 against the parent baseline) for all later training; gates currently failing are the only legitimate objectives of the next rung.

    Case. The C ladder ran one frozen 13-cell x 20-seed matrix at every rung with promotion = "new skill PASS and old skills within regression budget"; C1 was stopped and re-rooted precisely because it trained away the root's backward PASS (`fixed-acceptance-matrix-per-rung`, `preregistered-stop-criteria-per-rung`). The C4 product shipped only at 260/260 cells with zero regression.

    Coach application. Keep the ledger: every PASS adds a constraint row; propose rungs only against FAIL rows; treat any constraint violation as stop-and-attribute, never "the next rung might win it back".

    fixed-acceptance-matrix-per-rungpreregistered-stop-criteria-per-rung

  4. doctrine-4One variable per ladder rung - counted against what the checkpoint saw

    A rung changes one variable, where "one" is counted against the checkpoint's actual training state, not against the current config's diff; batching is allowed only when each change owns a disjoint symptom space with a pre-registered ablation order.

    Case. Two rungs failed identically because resuming s1e-500 under the evolved config silently added four plant variables the checkpoint had never seen ("单变量纪律不只看「我改了什么」,还要看「checkpoint 见过什么」" - `resume-state-dr-audit`). v8 legally batched four orthogonal fixes with a written ablation order (`orthogonal-batch-with-ablation-order`); v9 spent one run completing a 2x2 factorial so either outcome convicted a factor (`fill-the-missing-factorial-cell`); v10b's three-way ablation wrongfully convicted the clock and had to be retried fairly.

    Coach application. Before any resume: diff cfg against the checkpoint's logged training state. Before any batch: require the symptom-ownership map and ablation order in writing.

    resume-state-dr-auditorthogonal-batch-with-ablation-orderfill-the-missing-factorial-cell

  5. doctrine-5Pre-register risks, readings, and stop criteria before the ladder

    Before a ladder or risky rung, write down the known risks, the interpretation of every plausible outcome, and hit-any-one stop criteria - frozen before training, tightened when priors say results should come fast.

    Case. The C ladder opened with three numbered risks including the exact falsification condition for its own root choice; A/B arms carried "预注册读法(事后不改)" tables; a level expected to fail was run anyway for its pre-registered diagnostic value (`preregister-risks-and-fork-readings`). Stop criteria caught C4-redo rungs at +200 instead of full caps (`preregistered-stop-criteria-per-rung`); hardware sessions pre-registered per-config expected signatures and the disagreement rule "不改结论改账" (`preregistered-real-expectations`, `feasibility-accounts-lock-design-point`).

    Coach application. Refuse to open a rung without the written risk/reading/ stop block; after results, read conclusions off the pre-registered table and flag any post-hoc reinterpretation.

    preregister-risks-and-fork-readingspreregistered-stop-criteria-per-rungpreregistered-real-expectationsfeasibility-accounts-lock-design-point

  6. doctrine-6Plant parameters are measured, never invented

    Every plant number carries measurement provenance: armature = N^2 x rotor inertia from no-load tests, friction split by rig and by API column, torque limits shaped by per-joint gait peaks, latency traced through the real pipeline, masses weighed - and DR bands are additive around the measured nominal, sized to the measured dispersion.

    Case. Guessed friction was 2.5x low and guessed damping 5x high (`friction-measured-not-guessed`); armature had been 0 with a 9:1 gearbox (81x reflected inertia, `armature-n2-rotor-inertia`); a uniform torque derating was "the wrong shape" vs measured peaks (`torque-limit-shape-by-measured-peaks`); the delay implementation itself was a wrong plant for a whole lineage (`latency-lerp-reverse-extrapolation`); the run design point was locked by three accounts including the tau_limit/kd speed ceiling (`feasibility-accounts-lock-design-point`); identified friction had to land in the right simulator API columns to act at all (`sim-api-friction-columns`). The recovery and one-leg lines opened with the same kind of accounts before any reward existed - a connected static path and the torque along it for an armless get-up, and the gains single support needs to be holdable at all (`get-up-feasibility-accounts-before-training`, `single-support-gain-authority-probe`).

    Coach application. For any plant value in a config review, ask "measured how?"; reject absolute ranges with no nominal; check API column mapping and derived-asset regeneration whenever measured values land.

    friction-measured-not-guessedarmature-n2-rotor-inertiatorque-limit-shape-by-measured-peakslatency-lerp-reverse-extrapolationfeasibility-accounts-lock-design-pointsim-api-friction-columnsget-up-feasibility-accounts-before-trainingsingle-support-gain-authority-probe

  7. doctrine-7Sim2sim gate before sim2real - under deployment conditions

    Every checkpoint passes a second, independently built simulator before hardware, and both the gate and the smoke loop run under the measured deployment conditions (real pipeline delay, honest contact parameters, the deployment gain/power profile).

    Case. The standing order "先sim2sim 再sim2real" (`sim2sim-gate-before-sim2real`); acceptance flipped to match hardware only under measured condim/torsional friction (`eval-plant-honesty-contact-params`); gates moved permanently to `--delay 2` after the kicking incident (`pipeline-latency-is-plant-not-dr`); and the harness itself must be audited - a frame-convention bug in the cross-sim evaluator invalidated a whole line of verdicts (`body-frame-velocity-api-audit`). The recovery line's second simulator caught a torque penalty paid for by bracing the legs together (`torque-penalty-bought-by-leg-bracing`), and a 1.8x torque disagreement between the two plants stayed binding because its one surviving explanation was never tested (`torque-disagreement-between-simulators-unresolved`).

    Coach application. Block any hardware request lacking a second-sim PASS at deployment conditions; when sim2sim and training-side metrics disagree, treat the evaluator as a suspect too.

    sim2sim-gate-before-sim2realeval-plant-honesty-contact-paramspipeline-latency-is-plant-not-drbody-frame-velocity-api-audittorque-penalty-bought-by-leg-bracingtorque-disagreement-between-simulators-unresolved

  8. doctrine-8Observation honesty - the actor's inputs are a hardware contract

    The actor observes only signals the real robot produces with realistic noise; privileged truths go to the critic; history windows are estimators and must train under plant variation; rewards on quantities the actor cannot observe buy only average suppression, never closed-loop correction.

    Case. Ground-truth velocity/forces went critic-only (`observation-honesty-critic-only`); frame_hist under zero DR memorized the trainer's plant fingerprint - 0/20 transfer (`history-obs-needs-plant-variation`); world-frame yaw rewards could not teach pull-back because heading is unobservable to the actor - correction was routed to the deploy outer loop instead of breaking the contract (`reward-observability-limit`, `deploy-heading-loop-and-align-training`).

    Coach application. Audit every actor-obs element for hardware existence; require minimal plant jitter whenever history/recurrence exists; for each reward, ask "can the actor see this error?" and route correction tasks to outer loops.

    observation-honesty-critic-onlyhistory-obs-needs-plant-variationreward-observability-limitdeploy-heading-loop-and-align-training

  9. doctrine-9Reward economics are audited in realized currency

    Reward design decisions are made on realized per-step magnitudes under the actual policy and command distribution: price the do-nothing optimum before adding a mode, compare achieved values to the computed ignore-floor, calibrate thresholds between measured healthy and sick distributions, and ship every new penalty with a withdrawal clause.

    Case. feet_air_time at weight 2.0 realized 0.038 vs tracking 1.2 - drag was rational (`realized-contribution-audit`); ignoring a vy command cost 28-180x less than ignoring vx until a gated tracking term was added (`reward-cost-of-ignoring-audit`, `gate-new-reward-terms-by-command`); achieved-vs-floor separated "never learned" from "priced out" (`ignore-floor-diagnosis`); the foot-distance wall was placed between measured healthy (0.6% tax) and sick (55%) policies (`calibrate-threshold-between-healthy-and-sick`); the landing penalty carried a pre-registered stand-down condition and actually stood down (`calibration-threshold-with-withdrawal-clause`); two clearance terms were inert until zero-points and gate occupancy were checked (`inert-reward-term-audit`). A get-up policy sat because three gated terms paid the seated pose 84% of the return and the one term that could tell sitting from standing was an exp kernel reading 4.6e-5 at the real error (`seated-basin-dead-exp-kernel`); a torque-tail term was weighted by its measured steady value beside a peer term after the estimate proved 12x off (`tail-torque-needs-hinge-on-computed-demand`).

    Coach application. Never discuss weights in the abstract: demand the realized-contribution table, the ignore-floor number, and the healthy-pay calibration before any reward edit is approved.

    realized-contribution-auditreward-cost-of-ignoring-auditgate-new-reward-terms-by-commandignore-floor-diagnosiscalibrate-threshold-between-healthy-and-sickcalibration-threshold-with-withdrawal-clauseinert-reward-term-auditseated-basin-dead-exp-kerneltail-torque-needs-hinge-on-computed-demand

  10. doctrine-10The zero-cost option must be the desired behavior

    For every penalty, name what the zero-cost option is; penalize failure events (slip, saturation excess, contact in flight windows), never the motion or joints that healthy behavior uses; make degenerate strategies fatal via termination where penalties cannot price them out.

    Case. Joint-usage penalties for drift taxed a 1.4%-of-momentum channel 2.7/step and collapsed training; the slip penalty costs a non-slipping gait exactly zero (`penalize-the-slip-not-the-joint`). A frozen-at-clamp joint pays zero action-rate forever - only a pre-clip saturation penalty flips the cheat economics (`saturation-cheating-zero-rate-cost`). Ungated phase shaping made standing 42x more expensive than stepping and cooked the hip motors (`moving-gate-42x-stand-tax`); crouch-shuffling lived until a height termination deleted it (`termination-closes-degenerate-basin`). A gated penalty is an exit: the policy parked just outside an uprightness gate, then just under a height gate, to stop paying a stance tax, and only a positive band plus an always-on guard closed both (`penalty-gate-is-an-escape-hatch`); a soft-limit penalty that charged the standing pose itself bought a 4.1 deg lean (`soft-limit-penalty-charges-nominal-pose`); an unpriced foot attitude was spent on edge-standing (`unpriced-foot-attitude-is-a-free-variable`); and the one-leg line listed its cheapest cheats before training and still met one through a zero-gradient band (`enumerate-cheapest-cheats-before-training`, `binary-band-reward-fake-touchdown`).

    Coach application. Run the "零代价的选项是什么" audit on every proposed term; convert motion taxes into event-conditional penalties; check the termination set against each known degenerate strategy.

    penalize-the-slip-not-the-jointsaturation-cheating-zero-rate-costmoving-gate-42x-stand-taxtermination-closes-degenerate-basinpenalty-gate-is-an-escape-hatchsoft-limit-penalty-charges-nominal-poseunpriced-foot-attitude-is-a-free-variableenumerate-cheapest-cheats-before-trainingbinary-band-reward-fake-touchdown

  11. doctrine-11Measurement discipline: independent referees, signs, distributions

    A disputed measurement is adjudicated only by an independent algorithm from raw state; directional ability requires sign-antisymmetry under command reversal; bimodal metrics are reported as mode shares (never medians, never 3 seeds); ratios are not comparable when totals change; reward values compare only within one command distribution; single chaotic events never cross machines.

    Case. The triple reversal - a good metric was "refuted" by a sibling metric that shared the disease (`independent-referee-for-metric-disputes`, `body-frame-velocity-api-audit`); same-signed +/- responses were bias, not turning (`same-sign-response-is-yaw-bias`); the swing median sat in a bimodal gap (`median-hides-bimodal-distribution`); "v6 is jitterier" died on absolute energies (`ratio-metrics-need-absolute-check`); yaw gain measured 15x wrong in an oscillating frame (`heading-integral-not-body-rate`); a 44% improvement evaporated under same-distribution comparison (`same-distribution-reward-comparison`); drift direction was a limit cycle (`multiseed-sign-test-for-drift`); a cross-machine push cliff was chaos (`single-impulse-recovery-is-chaotic`).

    Coach application. Before accepting any surprising number: ask for the independent recomputation, the sign pair, the distribution shape, and the comparison conditions. Retract in writing when a metric falls.

    independent-referee-for-metric-disputesbody-frame-velocity-api-auditsame-sign-response-is-yaw-biasmedian-hides-bimodal-distributionratio-metrics-need-absolute-checkheading-integral-not-body-ratesame-distribution-reward-comparisonmultiseed-sign-test-for-driftsingle-impulse-recovery-is-chaotic

  12. doctrine-12The deployment pipeline is plant

    Irreducible pipeline properties - action latency, rate limits, power/torque scaling, teleop command mappings - are part of the nominal plant, modeled from day one and reproduced in every gate; deploy-side scalings are crutches that flag unmodeled plant, and they cannot be algebraically folded into training constants.

    Case. Right-leg kicking was over-trained-delay x loop gain; power 0.8 was a gain-reduction crutch that retired when the delay was modeled (`pipeline-latency-is-plant-not-dr`); power derating damages non-forward axes first (`power-scale-hurts-nonforward-axes`); training at 0.4 scale as the "twin" of deploying 0.5 x 0.8 collapsed 0/20 (`deploy-scaling-not-training-equivalent`); one shared teleop speed sent an out-of-band lateral command and the robot clipped its own foot (`teleop-command-band-per-axis`); the latency DR range had not even covered the measured pipeline (`latency-dr-covers-measured-pipeline`). A rate limiter added at deployment only clipped a policy that kept commanding (`deploy-rate-limiter-windup`); moved into training and anchored on the last command it became an integrator in the balance loop (`slew-anchor-is-an-integrator`); anchored on the measured angle it bounded torque and kept the bandwidth (`beta-anchored-action-target`). The walking lines' safe setting, power-scale 0.8, cut the ends of the recovery policy's full-range travel and left its spikes alone; a gain inside the trained band did the job (`power-derating-cuts-full-range-contract`).

    Coach application. Demand the measured pipeline latency/limits in the plant model and in gate conditions; treat every deploy-side derating as a question ("what is this compensating?"); block per-axis command sources that exceed training bands.

    pipeline-latency-is-plant-not-drpower-scale-hurts-nonforward-axesdeploy-scaling-not-training-equivalentteleop-command-band-per-axislatency-dr-covers-measured-pipelinedeploy-rate-limiter-windupslew-anchor-is-an-integratorbeta-anchored-action-targetpower-derating-cuts-full-range-contract

  13. doctrine-13DR budget is finite; its distribution is the measured support

    Robustness is a conserved budget: disturbance training on an already-hardened lineage borrows from existing margins; DR ranges span the measured deployment support - no fictitious tails (they buy degenerate gaits), no single constants (they allow thin-margin specialization); harden the plant only after the task distribution is final.

    Case. The same push dose helped a narrow lineage and damaged a balanced one - budget conservation (`push-dr-conditional-budget-conservation`); wide latency tails bought drag-glide, constant values shipped 60% thinner tilt margins - the answer is a narrow band on the measured support (`dr-tail-plant-continuation`, `constant-value-dr-overfits-margin`); task-first ordering because hardening a soon-to-change task wastes budget (`task-shaping-before-plant-hardening`); COM randomization used deliberately as a behavior-shaping tool, and rolled back on symptom per its own contract (`com-randomization-forces-leg-spread`, `com-dr-rollback-on-symptom`). DR that is switched on can still be thin: the run policy fell in the frontal plane its gain-and-latency randomization never touched (`thin-dr-judged-by-channel-coverage`), and a friction priority settled under one action contract had to be re-measured under the next (`friction-priority-re-measured-after-plant-change`).

    Coach application. Before any DR rung: check the untrained policy against the spec, the lineage's current DR load, and the measured real-world range; after it: audit retained margins, not just the new tolerance.

    push-dr-conditional-budget-conservationdr-tail-plant-continuationconstant-value-dr-overfits-margintask-shaping-before-plant-hardeningcom-randomization-forces-leg-spreadcom-dr-rollback-on-symptomthin-dr-judged-by-channel-coveragefriction-priority-re-measured-after-plant-change

  14. doctrine-14Gates measure what hardware feels: posture, margins, stripped assists

    Acceptance batteries carry posture-class rows (tilt max median, per-joint L/R asymmetry, temperature) beside task rows, graded margin columns beside binary gates, chirality scored per side, at least one condition that removes the environment's free stabilization, and validated predictive scalars promoted into the gate.

    Case. Three same-shaped judging errors - survival, displacement, wz-difference - all missed what the operator felt; posture metrics had the predictive power (`task-metrics-vs-posture-metrics`, `stand-gate-posture-not-survival`); binary survival saturated and hid a 60% margin gap (`constant-value-dr-overfits-margin`); v5 passed everything on the ground and failed suspended (`suspension-probe-removes-free-stabilizer`); the hip_roll (l+r) scalar predicted real drift direction and ordering and entered the battery (`hip-roll-sum-predicts-lateral-drift`); averages hide chirality (`chirality-scored-separately`); gait-quality gates are judged at speeds that demand a gait (`low-speed-commands-reward-dragging`). The recovery line added the rest of the kit: where failed episodes end, not only where they started (`end-state-confusion-matrix`); a frozen acceptance distribution with a pinned seed (`frozen-acceptance-distribution-and-pinned-seed`); video of the metric rollout itself (`video-as-acceptance-record`); and the admission that a 10 s episode cannot see a stance that fails after a minute (`episode-length-bounds-what-a-gate-sees`). The one-leg line removed a foot-spacing wall that no gate measured, and the feet met on hardware (`removed-wall-returns-on-hardware`).

    Coach application. Review every battery for posture rows, margin columns, per-side scoring, and an assist-stripped condition; when operator feel and gates disagree, suspect the metric class first.

    task-metrics-vs-posture-metricsstand-gate-posture-not-survivalconstant-value-dr-overfits-marginsuspension-probe-removes-free-stabilizerhip-roll-sum-predicts-lateral-driftchirality-scored-separatelylow-speed-commands-reward-draggingend-state-confusion-matrixfrozen-acceptance-distribution-and-pinned-seedvideo-as-acceptance-recordepisode-length-bounds-what-a-gate-seesremoved-wall-returns-on-hardware

  15. doctrine-15Fork and root selection: recoverability, maturity, frozen rewards

    Choose fork roots by which candidate's deficits the coming training can pay back (precision is recoverable; lost plasticity, symmetry, and margins are not); prefer mature checkpoints as roots even when younger ones score better as products; never fine-tune through a reward change - continuation is legal only with the reward frozen and plant/DR widening one rung at a time.

    Case. s1e-500 beat higher-precision candidates because its exclusive strengths were unrecoverable (`fork-root-recoverable-shortfall`); the b300 arm proved maturity is capital against adaptation shock (`root-maturity-vs-product-quality`); the B-arm scatter/half-recover/collapse signature falsified reward-change fine-tuning and drew the legal boundary for S2 continuation (`fine-tune-reward-change-falsified`).

    Coach application. For root debates, build the exclusive-strengths table and ask "which side can be trained back?"; require dual-arm evidence for maturity claims; classify any proposed continuation as reward-frozen or not before approving.

    fork-root-recoverable-shortfallroot-maturity-vs-product-qualityfine-tune-reward-change-falsified

  16. doctrine-16Curricula: verified engagement, lineage counters, disease-phase gating

    Automatic curricula must prove they engage (a saturated ratchet is constant DR wearing a curriculum's name); every ramp counts lineage-cumulative progress, not per-process steps; penalties aimed at late-stage pathologies ramp in after exploration noise decays; difficulty rises on measured per-stratum success, never on schedule.

    Case. The s1f ratchet capped at iter 248 and never engaged (`auto-curriculum-engagement-check`); the saturation ramp re-fired at +600 after every resume and no shipped product ever saw the penalty (`curriculum-counter-lineage-steps`); the same penalty worked once gated to the disease phase and became an untouchable mechanism (`gate-penalties-to-the-disease-phase`); record-high aggregate reward hid a fully-failing delay stratum (`aggregate-metrics-mask-subgroup-failure`); bucket share is not a gradient lever (`bucket-share-is-not-a-gradient-lever`). An assist curriculum keyed to a pooled success share was withdrawn on the strength of the categories that already worked (`curriculum-criterion-conditioned-on-lagging-category`); a pace set by per-step income moved only when that income was time-gated (`per-step-income-drives-speed-time-gate`), and the same gate had to be retired in a lineage without the disease (`time-gate-vs-wide-stance-retire-the-fix`).

    Coach application. Ask every curriculum three questions: does it engage (show the internal state)? what does it count (process or lineage)? when is it present (against the pathology's phase)? Check where shipped checkpoints sit relative to every ramp.

    auto-curriculum-engagement-checkcurriculum-counter-lineage-stepsgate-penalties-to-the-disease-phaseaggregate-metrics-mask-subgroup-failurebucket-share-is-not-a-gradient-levercurriculum-criterion-conditioned-on-lagging-categoryper-step-income-drives-speed-time-gatetime-gate-vs-wide-stance-retire-the-fix

  17. doctrine-17Probe before training: feasibility first, hypotheses in tables

    After two failed training attempts at a skill, stop training: demonstrate the behavior open-loop, enumerate hypotheses in a written table audited against actual configs cheapest-first, race one probe per side of the sim2real boundary for hardware-only pathologies, and use suspended tests to acquit or convict actuators before blaming authority.

    Case. "在黑暗里试钥匙" - four sidewalk rungs failed until an open-loop probe separated exploration/waveform/authority in one experiment (`open-loop-probe-before-reward-tuning`); the foot-drag mystery fell to a seven-hypothesis config audit (`hypothesis-table-code-audit`); the period-doubling was resolved by racing a reward-side and a plant-side evidence line - and both paid off, one per sub-case (`period-doubling-evidence-race`); the suspended test acquitted the roll actuator in one measurement (`suspended-test-isolates-actuator-authority`). A read-only configuration probe told a wall from a slope in the recovery line's seated basin (`configuration-probe-wall-not-slope`), and the fix it pointed to - where the feet are - took prone from 0/159 to 158/159 (`prone-dead-end-is-foot-placement`); a knob that did not move its variable was recorded as no test of the idea (`dof-vel-penalty-is-not-a-pacing-knob`).

    Coach application. When a skill resists training, prescribe the probe before any further reward edits; require verified target trajectories before imitation terms; keep a falsified-fixes list so closed roads stay closed (`amplitude-cut-falsified-yaw-fix`).

    open-loop-probe-before-reward-tuninghypothesis-table-code-auditperiod-doubling-evidence-racesuspended-test-isolates-actuator-authorityconfiguration-probe-wall-not-slopeprone-dead-end-is-foot-placementdof-vel-penalty-is-not-a-pacing-knobamplitude-cut-falsified-yaw-fix

  18. doctrine-18External advice is recomputed locally; values transfer as ratios

    Every external suggestion is classified adopt / already-have / modify / trap by recomputing its claim on the local reward table and probe data; numeric values transfer only as dimensionless ratios (to tracking weight, leg length, sqrt(gL), control rate); citations are verified to exist.

    Case. "Start vy very small" would have destroyed sidewalk learning on this reward table - the gradient scales quadratically (`external-advice-audit-against-own-arithmetic`); swing-height targets and weights transferred correctly only through leg-length and tracking-ratio scaling (`transfer-ratios-not-absolutes`); the "6-step delay" was refused for lacking a control rate (`latency-dr-covers-measured-pipeline`); a borrowed reference's structure was FK-verified and its amplitude re-derived from the division of labor (`reference-structure-fk-amplitude-division`); retrieval agents fabricated verbatim arXiv quotes - only source-verifiable material was used; and one dismissed suggestion later proved right for a different mechanism, and was credited (`cycle-average-tracking-for-gait-quantities`). An advisor's staged state machine turned out to exist in none of the three papers it cited, and reading them changed the plan (`advisor-paraphrase-vs-paper`).

    Coach application. Intercept every "paper X does Y" with the local recomputation; convert absolutes to ratios before comparison; verify quotes; revisit dismissed advice when new mechanisms appear.

    external-advice-audit-against-own-arithmetictransfer-ratios-not-absoluteslatency-dr-covers-measured-pipelinereference-structure-fk-amplitude-divisioncycle-average-tracking-for-gait-quantitiesadvisor-paraphrase-vs-paper

  19. doctrine-19Hardware sessions are scripted experiments, not tuning sessions

    Real-robot time executes a pre-registered matrix: risk-ordered (baseline first, fragile last with a spotter), stage-gated (suspended smoke before ground), A/B sessions bracketed by a repeated reference run, operators briefed on measured zero-command and untrained-axis behavior, chirality-aware disturbance protocols, no field tuning - the only legal field changes are scripted, single-variable, and self-reversing.

    Case. The S2 acceptance sheet (`risk-ordered-real-deployment`, `battery-bracketed-real-ab`, `know-zero-command-behavior`, `push-test-chirality-protocol`, `no-field-tuning-protocol`); the RAM-only torque experiment with automatic power-cycle rollback (`reversible-single-variable-field-experiments`); and the sim-veto rule - even sim's condemnations get one safeguarded hardware check when they judge the purpose-built configuration (`sim-veto-needs-real-confirmation`). The recovery line's first real run went ahead with its preconditions unmet and was stopped as dangerous (`first-real-get-up-violent-stage-one-policy`); after it: a staged hang, mat and floor protocol (`staged-hang-mat-floor-for-get-up`), a fixed power-cycle pre-flight and two-machine discipline (`power-cycle-preflight`, `two-machine-config-discipline`), a fall guard replaced rather than switched off (`fall-guard-becomes-a-state`), and logs that are part of the run (`hardware-log-is-the-attribution-input`).

    Coach application. Turn every hardware request into a runbook with order, gates, brackets, briefing, and anomaly plays; refuse improvised parameter changes on the floor.

    risk-ordered-real-deploymentbattery-bracketed-real-abknow-zero-command-behaviorpush-test-chirality-protocolno-field-tuning-protocolreversible-single-variable-field-experimentssim-veto-needs-real-confirmationfirst-real-get-up-violent-stage-one-policystaged-hang-mat-floor-for-get-uppower-cycle-preflighttwo-machine-config-disciplinefall-guard-becomes-a-statehardware-log-is-the-attribution-input

  20. doctrine-20Close questions in writing; restart when the debt is structural

    Audited questions get frozen verdicts with citable wording and an explicit reopening bar; hardware verdicts are dated by deployment-stack and calibration state and expire when those change; and when successive rungs shuffle symptoms without net progress, freeze the lineage as regression baselines, pay the structural debts, and retrain minimal - carrying laws and instruments, not weights.

    Case. The chirality and COM questions were closed with frozen wording and "no reopening without new hard evidence" (`frozen-verdicts-semantic-boundaries`); v5/v6's condemnations expired with the deploy stack (`stale-verdicts-under-old-stack`); a 2-degree calibration fix moved the whole runnable envelope (`zero-offset-calibration-shifts-envelope`); plant upgrades are era boundaries with paired re-baselining (`plant-swap-invariants-vs-shifts`); and the 2026-08-05 reset froze v5-v11, fixed the latency FIFO / manifest / sampling / reward-table debts, and restarted - producing the lineage that reached hardware SOTA (`freeze-lineage-fix-structure-restart`, `minimal-reward-table-with-provenance`). The recovery line's real-robot verdicts ended up in three places that disagree, one of them an undated note in a command file (`write-hardware-verdicts-back`).

    Coach application. Maintain the closed-questions ledger and quote it when symptoms recur; stamp verdicts with stack/calibration versions; when a team is three rungs into symptom-shuffling, raise the restart question explicitly with the freeze-fix-restart pattern.

    frozen-verdicts-semantic-boundariesstale-verdicts-under-old-stackzero-offset-calibration-shifts-envelopeplant-swap-invariants-vs-shiftsfreeze-lineage-fix-structure-restartminimal-reward-table-with-provenancewrite-hardware-verdicts-back

  21. doctrine-21Name the quantity in the space it lives in

    A goal, reward term or acceptance criterion about the feet, the base or the contact state is computed from the quantity itself - world poses, forces, per-category outcomes - never through a joint-angle, single-signal or pooled stand-in that assumes everything else sits at nominal; and every detector is validated on a behaviour known not to contain the event before it becomes a gate.

    Case. The recovery line was caught three times: |ankle roll| as "flat feet" sold stance width and the real robot slid into the splits, a hip-roll criterion was confounded by 50 deg of yaw, and the joint table said 0.271 m where the feet were 0.159 m apart; task-space terms produced the first flat, wide stance (`joint-space-proxy-for-task-space-quantity`). Flight detection lied in both directions across two lines - foot height flagged 40% false flight on a walking gait, contact force alone flagged slip chatter as hops (`contact-detector-single-signal-lies`). A pooled height average described a robot that did not exist - six in ten standing, four in ten sitting (`zero-partial-credit-is-not-an-iteration-problem`) - and the walking line had learned the same lesson on yaw rate (`heading-integral-not-body-rate`).

    Coach application. For every reward term and gate row, ask what physical quantity it stands for and whether it is measured directly; flag joint-space or single-signal stand-ins for task-space goals, ask for a detector validated on a negative control, and split pooled metrics by category before reading them.

    joint-space-proxy-for-task-space-quantitycontact-detector-single-signal-lieszero-partial-credit-is-not-an-iteration-problemheading-integral-not-body-rate

  22. doctrine-22Continuation needs a live gradient; a release is chosen by a scan

    Continue a converged policy only on a change that creates a live gradient, on a short budget, with every checkpoint scanned on the transfer axis; choose a release by running the full battery over a band of checkpoints and stop on signals, never by taking the last one; and when edits to the terminal phase cannot move a behaviour, roll back and retrain with the constraint present from the start, keeping the order in which the lineage acquired its mechanisms as explicit curriculum phases.

    Case. A continuation with no new gradient drifted MuJoCo transfer from 100/98% to 80/28% while every Isaac gate stayed perfect, and a live-gradient continuation at the same depth kept it (`converged-continuation-is-poison`). One-leg checkpoints 100 iterations apart failed 1 and 38 of 40 cells, and late ones degraded (`checkpoint-choice-is-a-full-gate-scan`). Four in-lineage stance fixes failed because the stance was the end of the get-up path, and from scratch it grew right (`stance-decided-by-get-up-path`); fixes stacked on degraded states were rolled back by the user (`stop-stacking-roll-back-and-audit`); and the lineage's final recipe, trained from scratch in one run, sat at 0% because the order of its curriculum was part of the product (`curriculum-history-is-part-of-the-product`). The omni line's short adaptation budgets and mature roots are the same law seen from the other side (`continuation-budget-not-from-zero`, `root-maturity-vs-product-quality`).

    Coach application. Before approving a continuation, ask for the new gradient, the budget and the transfer axis in the scan; before approving a release, ask for the scan; after three rungs without progress on the target, propose rolling back to the last good checkpoint and a from-scratch phase plan instead of a fourth patch.

    converged-continuation-is-poisoncheckpoint-choice-is-a-full-gate-scanstance-decided-by-get-up-pathstop-stacking-roll-back-and-auditcurriculum-history-is-part-of-the-productcontinuation-budget-not-from-zeroroot-maturity-vs-product-quality

Experience cards

106 cards matching “write-hardware-verdicts-back”.

  • The recovery line's real-robot verdicts live in three places that disagree - the spec's "fairly stable, first real stand-up" for v2_6, an undated runbook note that only v3_1p1c works, and a first run whose details were never recordedwrite-hardware-verdicts-back
    Observed oncerecoveryreal-deployreal-acceptanceprocessattribution

    A hardware verdict is a dated entry in the authoritative ledger - policy file and stamp, gain profile, floor, battery, tries, log file, what was seen - written back the same day; a note in a command file is a pointer, not a verdict, and a newer verdict that contradicts an older one must say so.

    Symptom

    Asked "which recovery policy works on the real robot", the sources give different answers, and none of them carries the conditions of the test.

    Context

    08-09: the first real run was stopped as violent and dangerous; which ONNX, which gain profile and whether a log existed were marked "to be recorded" and never were. 08-11: v2_6 was "fairly stable", the line's first real get-up, with splits after standing; v2_5b's result and both CSVs were "to be reported". 08-14: v3_1p1c was stamped and pushed, with "the real first test still needs the user present"; the spec records no hardware result for it. The operator runbook (undated) puts above the v2_6 and v2_5b floor commands the note that none of the recovery policies below work, only recovery_v3_1p1c - a verdict never written back into the spec, with no date, floor, battery, number of tries or log attached.

    Change

    None recorded in the sources; this card records the gap.

    Outcome

    The line's authoritative record ends with v3_1p1c as the product awaiting its first real test, while the operator's note implies it is the only one that works and that v2_6 (recorded as a success) does not.

    Mechanism

    Verdicts given at the robot travel by word of mouth and command-file comments; without a record carrying the conditions, a later reader cannot tell a changed verdict from a changed floor, battery or stack.

    Conflicts

    §43 (2026-08-11) records v2_6 as the first successful real get-up ("fairly stable"); the undated runbook says every recovery policy except recovery_v3_1p1c does not work; §49 (2026-08-14) says v3_1p1c's first real test was still pending. The runbook's claim has no date and was never written back to the spec, so it cannot be ordered against §43.

    Applies when

    • choosing which policy to deploy from an operator's notes
    • a hardware session ends without a written result
    • two documents disagree about what worked on the robot
    “下面的recovery都不行 只有recovery_v3_1p1c.onnx”
    RL系统/FOLLOW THIS copy 2.md § #### Recovery Policy (operator runbook, undated)
  • Write each config's expected hardware signature before the session - and if reality disagrees, change the books, not the conclusionpreregistered-real-expectations
    Replicatedomnireal-acceptancereal-acceptanceprocesssim2sim

    Before hardware runs, write per-config expected signatures and the disagreement rule (hardware outranks sim; discrepancies get recorded, not reconciled); validate the harness by checking it reproduces at least one known real behavior.

    Symptom

    Hardware impressions are easily narrated after the fact; without written expectations, any real-robot outcome can be made to "match" the sim story.

    Context

    The S2 acceptance sheet carried a section titled "sim 侧预注册预期 (事后核对, 不许事后改)" - per-configuration behavioral signatures written before the session: s1e@0.8 the disturbance king (push 159/160, zero chirality, all-mu 20/20) at the cost of speed gates 0/20 and zero-command wander ~0.98 m with -29.5 deg/20 s rotation; fric-3000 "walks accurately but is easier to push over"; fric-2400 neither. Credibility check included: the sim harness had reproduced the already-recorded real behavior (pace in place + right drift + net rotation -30 deg/20 s), which "提高本单全部预期的可信度". The anomaly clause fixed the epistemics in advance: if results systematically disagree with sim, "不改结论改账" - don't massage the conclusion, write the discrepancy into the books, and per the earlier zero-warning lesson, hardware wins.

    Change

    Every hardware session ships with a pre-registered expectation table (signature per config), a baseline-match credibility check, and a written precedence rule for disagreement.

    Outcome

    The A/B session became falsifiable: agreement confirms the proxy, disagreement is booked as a proxy-bias finding rather than argued away.

    Mechanism

    Pre-registration converts qualitative hardware sessions into tests of the sim-to-real mapping itself; a reproduced known behavior calibrates trust in the remaining predictions; and fixing "who wins on disagreement" beforehand prevents authority from drifting to whichever source flatters the plan.

    Applies when

    • planning any hardware acceptance or A/B session
    • the sim harness's credibility in this regime is unestablished
    • post-session write-ups tempt narrative fitting
    “⚠️ sim 复现了真机已记录的「原地踏步 + 右漂 + 净旋 −30°/20s」—— harness 与真机行为对得上, 提高本单全部预期的可信度。… 结果与 sim 系统性不符 → 不改结论改账: 写进 README 该节, 按 「Isaac 指标三次零预警」的教训, 以真机为准。”
    train/REAL_RUN_S2.md § 2. sim 侧预注册预期 (事后核对, 不许事后改) / 4. 异常处置
  • A real-robot verdict is (policy x deployment stack) - when the stack changes materially, old verdicts expirestale-verdicts-under-old-stack
    Mechanism understoodwalkreal-acceptancereal-acceptanceattributionprocess

    Date every hardware verdict with the deployment-stack version it was measured under; after any material stack change, re-test before trusting old condemnations or old praises - with the interpretation of each possible result written down first.

    Symptom

    walk_v5 stood condemned as "kicks wildly" and walk_v6 as "cannot walk unassisted" - but those verdicts were issued under an earlier deployment stack (--heading did not exist yet, several fixes had just landed); only v7 had ever run under the current unified stack.

    Context

    New sim evidence sharpened the doubt: a same-harness four-version sweep showed v6 was the HEALTHIEST archive at the real operating point (cmd 0.15: dominant frequency locked at 2.50, steps 35:35 perfectly symmetric, foot distance 203/190 mm best of four, mean tilt 4.2 deg, saturation 15%). A full re-test under the unified stack was scheduled with per-version questions and a pre-filled interpretation table ("判读表(预填假设,回来对号)"): e.g. v6 walks + frequency ~2.5 -> old verdict was the stack's fault, v6 becomes the comparison champion; v6 walks but at ~1.25 -> period-doubling on hardware = confirmed plant gap, actuator fitting promoted to mainline; v5 no longer kicks -> the kicking was an old-stack artifact.

    Change

    All four versions re-queued on hardware under one stack (same torque limits, slew profile, heading loop, logging), with the version-specific legacy profile pinned; verdicts held provisional until re-issued.

    Outcome

    The re-test design separated policy properties from stack artifacts before any policy was permanently written off - and turned each outcome into a specific conclusion via the pre-filled table.

    Mechanism

    A deployed behavior is produced by the policy plus everything between it and the motors (heading loop, slew limits, torque caps, clock); verdicts implicitly condition on that whole stack. Fixing the stack invalidates the conditioning, so old failures may be stack artifacts and old successes may not survive either.

    Applies when

    • deployment tooling (limits, filters, loops) changed since a policy was last judged
    • deciding which historical policy is the rightful baseline
    • a sim sweep contradicts an old hardware verdict
    “只有 v7 在完整的今日部署栈下上过真机 … v5"左右乱踢"、v6"未能自主"的判决全部来自更早的栈(--heading 尚不存在, 部分修复刚落地)——判决已过期。且 2026-08-02 四代同机仿真横测翻出了新证据:v6 在真机工况(cmd 0.15)下是四代里最健康的仿真档案”
    train/REAL_SWEEP_V5_V8.md § 0. 为什么重测
  • A 2-degree joint-zero calibration fix moved the whole runnable envelope - re-test old "cannot run" verdicts after recalibrationzero-offset-calibration-shifts-envelope
    Observed onceomnireal-deployreal-acceptancehardwareplant-calibrationattribution

    Date every hardware verdict with the calibration state; after any zero/mount recalibration, re-test previously condemned policy-power combinations and previously "unexplainable" posture offsets before attributing either to training or model.

    Symptom

    s1d was on record as "only runs at power 0.7" (kicked wildly at 0.8); after a calibration pass, the same policy ran 12 s at 0.8 with no kicking at all.

    Context

    The calibration had fixed a 2.08 deg zero offset on r_hip_roll - exactly the constant error source on the dominant joint of the kicking oscillation loop ("恰是乱踢振荡环主导关节的常值误差源"). The three-generation post-calibration hardware sweep also closed a second case: the robot's mysterious "backward lean" disappeared after calibration, and the sim-real posture difference collapsed from opposite-sign 5+ deg to same-sign ~2 deg ("后仰案实质了结") - the lean had been a sensing/zero artifact, not a mass-model error. Booked consequence: if the s1d recovery re-verifies, "真机可跑档整体 上移" - every policy's runnable power envelope shifts up, and downstream lineages' hardware expectations get revised.

    Change

    Joint-zero and mount calibration promoted from setup chore to a variable that dates hardware verdicts: verdicts about which power/scale levels a policy can run are conditioned on the calibration state they were measured under.

    Outcome

    One policy rehabilitated at a higher power level; one standing sim-real posture discrepancy closed without touching model or training; a pending re-verification booked rather than asserted.

    Mechanism

    A constant joint-zero error acts as a persistent disturbance injected at the feedback loop's most-loaded joint; near an oscillation threshold, removing a 2-degree bias is the difference between a stable and an unstable loop. Since the error is additive and machine-side, it shifts every policy's stability envelope simultaneously - which is why verdicts must carry their calibration date.

    Conflicts

    The s1d rehabilitation awaited one confirming re-run at the time of writing ("待复核一跑坐实") - the offset-as-cause reading is the head suspect, not a closed verdict.

    Applies when

    • a policy oscillates at a power level others tolerate
    • sim and real disagree on a constant posture offset
    • deciding whether to re-test old hardware verdicts after maintenance/calibration
    “发现①:s1d@0.8 能跑了(旧账「只有 0.7 能跑」)——12s 无乱踢。头号嫌疑 = 标定修正:r_hip_roll offset 修 2.08°,恰是乱踢振荡环主导关节的常值误差源。… 发现②:「后仰」标定后消失 … sim-real 姿态差从反号 5°+ 收敛到同号 2°,后仰案实质了结。”
    train/README.md § 真机 @0.8 三代横评(2026-08-07 标定后)
  • After installing the measured plant, re-run all generations paired on old and new plant - identity metrics carry verdicts, physics metrics re-baselineplant-swap-invariants-vs-shifts
    Mechanism understoodwalksim2sim-gatesim2simplant-calibrationgate-batteryattribution

    Treat every plant upgrade as an era boundary: re-run the retained policy set paired (same seeds/flags) on both plants, carry forward only verdicts whose metrics proved plant-invariant, re-baseline the rest - and mine the systematic shifts as measurements of the old plant's biases.

    Symptom

    With the plant finally fully measured (weighed masses 9.792 kg, bench-identified armature, in-situ friction), no historical sim number was comparable to new runs - "历史 sim 数字跨纪元不可比" - and it was unknown which historical verdicts still held.

    Context

    The era-2c cross-test ran all seven walk generations on the complete plant under one harness (14/14 survived), then re-ran the same 14 configurations on the OLD plant retrieved from git, same flags and seeds, with a self-check (one historical record reproduced digit-for-digit). The split was clean. Policy-identity metrics moved essentially zero across the plant swap - dominant frequency (v7's period-doubling 1.20 -> 1.20), knee amplitude (9.9 -> 10.0), foot distance (+/-2 mm), saturation (100 -> 100, 0 -> 0) - so all seven cross-generation verdicts (freeze signature, saturation-line closure, knee-collapse location, slip-penalty accounting, N2 lineage, v6's balance, v11's triad) were re-confirmed on the honest plant. Plant-physics metrics shifted systematically with ordering preserved: slip down 10-25% (measured friction makes ground-twisting costlier), landing vertical velocity down 15-50% ("旧 plant 高估落地 凶度"第二次独立证实), landing force mixed (mass up 2.2% vs friction braking the swing - two effects fighting). Exactly ONE behavior-level change: v8's low-speed period-doubling vanished (1.30 -> 2.50, lift normalizing) - confirming it had been machine-dependent bifurcation-edge behavior that armature+friction push off the knife edge, while v7's period-doubling stood untouched: saturation-freeze-driven, a policy property, not a numerical accident.

    Change

    Era re-baselining protocol: after any plant upgrade, one paired same-seed sweep of all retained generations on old and new plant; verdicts keyed to identity metrics carry over, thresholds re-read against the new-plant table, and the differences themselves become plant-physics findings.

    Outcome

    Seven verdicts survived with evidence rather than assumption; two causes of the period-doubling family were separated with plant-side proof; and the sim's landing-violence overestimate was independently confirmed a second time.

    Mechanism

    A policy's structural properties (frequencies, amplitudes, frozen joints) are functions of its weights and survive plant changes; contact-mediated quantities are joint properties of policy and plant and shift when the plant becomes honest. Pairing seeds across plants isolates the plant's contribution exactly, so the sweep both validates history and measures what the old plant had been lying about.

    Applies when

    • installing measured masses/armature/friction into the sim
    • historical thresholds are cited across a plant change
    • a hardware-only behavior might be bifurcation-edge sensitivity
    “策略身份指标逐位不动:主频(v7 1.20→1.20)、膝摆 … 这些是策略属性,plant 换代携带无损,历史定论因此全部成立。… 唯一行为级变化:v8@0.15 的倍周期消失(主频 1.30→2.50…)——印证当时"分岔边缘、机器相关"的判定:armature+摩擦把 v8 推离刀锋;v7 的倍周期纹丝不动(1.20→1.20),它是饱和冻结驱动的深层属性,不是数值巧合。”
    train/README.md § 纪元 2c 全代同机横测 (2026-08-04): 完全体 plant 上历史结论全部存活
  • A proposal in the runbook - torque and action limits as versioned safety tiers (classroom / research / expert) written to motor RAM and read back, separate from the reward's effort penalty - recorded as a proposal, its implementation unrecordedsafety-limits-are-a-layer-not-a-reward
    Hypothesisinfrareal-deployhardwareprocessreal-acceptance

    Keep hardware limits as an explicit, versioned safety layer (tiers written and read back at start, the persisted default the safest one) and the effort penalty as a behaviour layer; when a skill needs more torque, change tier deliberately rather than trading one layer against the other.

    Symptom

    Running and jumping need more torque than the deployed limits allow, and the temptation is to trade the training-side effort penalty against the hardware limit, or to hand a new user a robot "tuned however the last person left it".

    Context

    A message pasted into the operator runbook (undated, citing Berkeley's practice of storing the full motor configuration as JSON with write and read-back scripts) proposes: configuration is a versioned artifact, not a verbal agreement; three safety tiers in robot.yaml beside the gain and policy profiles - classroom (RS06 limited to 10 N*m, lateral joints clamped: "however bad the policy, it only moves awkwardly"), research (14 N*m, clamps at twice the measured need, the default) and expert (the 36 N*m rating, joint limits only, requiring an explicit flag); deploy writes the tier to motor RAM at start and reads it back, while the stored copy stays classroom so a power cut returns to the safest state. It frames limits as the safety layer and the effort penalty as the behaviour layer - more torque for running means switching tier, not weakening the penalty.

    Change

    None recorded: the message ends by asking which to do first, a rollback or the tiers.

    Outcome

    The sources do not record the tiers being implemented; the deployed limits stayed at 12/17/11 N*m through the recovery and one-leg lines (the one-leg spec treats raising the RS06 limit as a separate, unapproved hardware decision). Related and recorded elsewhere: torque limits were written to RAM only in a scripted, self-reversing field experiment.

    Mechanism

    Hardware limits bound the damage any policy can do; reward terms shape what a policy prefers. Mixing them either weakens safety to buy behaviour or distorts behaviour to buy safety.

    Applies when

    • a new skill needs more torque than the deployed limits
    • robots are handed to students or new users
    • motor configuration lives in people's heads or in the firmware only
    “配置是版本化的产物,不是口头约定。 … deploy_policy 启动时按档写进电机 RAM 并读回校验(落盘的那份永远保持 classroom,断电自动回到最安全状态)。 … 限幅是安全层,dof_torques_l2 是行为塑造层,它们在不同的层,不冲突。跑步要更大力矩就换档,而不是去动训练里的省力惩罚。”
    RL系统/FOLLOW THIS copy 2.md § 面向 developer / 教育机构该怎么做 (pasted proposal, undated)
  • The +/-50 mm lateral COM randomization meant to spread the legs coincided with legs pulling IN - rolled back per its own pre-registered contractcom-dr-rollback-on-symptom
    Observed oncewalkdr-tuningdomain-randomizationattributiongate-battery

    When adopting a DR value that covers no local measurement, write its intent and rollback trigger into the config at adoption time; roll it back as the control arm the moment the symptom contradicts the intent, and promote the symptom's metric into the acceptance battery.

    Symptom

    After v7 adopted the reference developer's oversized lateral COM randomization (+/-50 mm) explicitly to force leg spread, the real robot's legs narrowed instead - lateral mean 154 mm / closest 107 mm in sim (nominal 214.5), narrower still on hardware with occasional leg contact.

    Context

    The rollback was clean because the adoption had been honest: the robot.yaml comment recorded the intent AND that the +/-50 value covered no local measurement (only a 16/7 mm measured offset existed; even the prior widening to +/-20 was subjective), plus the reference's own reported side effect (base sway) and the note "这一项要单独跑、 单独归因". When the opposite symptom appeared, v8 returned y to +/-20 mm as the control arm ("要么没起作用、要么帮了倒忙 … 按约定退回做 对照"), kept x/z untouched (a noise-level difference not worth another variable), and named the second suspect: the landing penalty itself, via the reference's own three-link chain (landing penalty -> stance narrows -> spacing penalty needed). A gate lesson was booked in the same table: v7's sim numbers had ALREADY crossed the line (154/107 vs v5's 182/147) - "这个指标本可拦下 v7" - so foot-distance became a standing acceptance row (min >120 mm, zero leg-leg contacts).

    Change

    base_com_offset_m y: 0.050 -> 0.020 (x/z kept), regenerated through the export tool rather than hand-editing derived files; foot-distance acceptance row added.

    Outcome

    A borrowed DR lever with no local measurement basis was retired the moment its symptom contradicted its purpose, at single-variable cost; the metric that would have caught it pre-hardware entered the gate.

    Mechanism

    DR ranges shape behavior through the policy's robustness strategy, which is jointly determined with every reward term; a lever that forces stance width on one robot can be dominated by a stronger narrowing pressure (landing softness) on another. Levers adopted without local measurement must carry their own rollback trigger, because there is no nominal to argue from when they misbehave.

    Conflicts

    Causality is not fully closed in the source: the narrowing may come from the landing penalty rather than the COM lever ("腿距的第二嫌疑人是 ④ 本身"); the rollback is the pre-agreed control experiment, not a verdict that the lever caused the narrowing.

    Applies when

    • importing DR ranges or behavioral-forcing randomizations from references
    • a DR lever's observed effect contradicts its documented purpose
    • a sim metric existed that would have caught a shipped regression
    “⑥ 的本意 … 是逼策略把脚分开;真机结果是脚向内收且偶发相碰——要么没起作用、要么帮了倒忙。… 注释当时就写了"这一项要单独跑、单独归因"。现在症状出现了,按约定退回做对照。”
    train/WALK_V8_SPEC.md § 3. 改动 C — 质心随机化退回(撤销 v7-⑥ 的 y 项)
  • A hardware run without its log is an anecdote - the first real get-up's policy, gain profile and log were never recorded, two CSVs stayed "to be reported", and runbook commands wrote different policies' logs under one copied filenamehardware-log-is-the-attribution-input
    Replicatedinfrareal-deployreal-acceptancemeasurementprocess

    Make the log part of the run: name it from the policy and conditions automatically (never by hand-copied filenames), record the policy digest and gain profile inside it, include what the open questions need (torque, joint positions and targets), and treat a session without a collected log as incomplete.

    Symptom

    The recovery line's oldest open question - whether Isaac or MuJoCo reads torque demand correctly - was waiting on real-robot logs that never arrived, and the verdicts that did arrive could not be tied to files.

    Context

    deploy_policy writes a CSV per run (--log); the runbook's own analysis snippet reads its joint-position, target and action columns (q_, tgt_, act_), and the recovery hanging checklist asks for torque and joint logs for the whole run, to be compared with simulation. The first real get-up (08-09): policy, gain profile and log "to be recorded later". The first real A/B (08-11): v2_5b's result and both policies' CSVs "to be reported". In the runbook's walking commands, three runs of two different c4 policies log to real_s1e_pw08_teleop_0808.csv, and s1e and s2e_fric runs log to real_c2_700_pw08_teleop_0808.csv - filenames copied from other commands.

    Change

    None recorded; the spec kept listing the open-loop comparison as waiting for real logs.

    Outcome

    No real-robot log appears in the recovery spec through §50, so the simulator disagreement stayed unresolved and hardware verdicts stayed unattached to data.

    Mechanism

    Attribution needs the run's identity (policy digest, profile, conditions) and its signals in one artifact; a filename copied from another command mislabels the file, and a log not collected at the session is rarely collected later.

    Applies when

    • planning a hardware session whose result should settle a sim question
    • log filenames are typed or pasted by hand
    • hardware feedback arrives as prose without files
    “python tools/deploy_policy.py --policy train/policies/omni_c4_ff800_pj.onnx … --log train/real_logs/real_s1e_pw08_teleop_0808.csv … q,t,a=d[:,c("q_")],d[:,c("tgt_")],d[:,c("act_")]”
    RL系统/FOLLOW THIS copy 2.md § Walk 遥控 / S2 / csv 分析片段 (operator runbook, undated)
  • Four consecutive fixes were each continued from the previous fix's degraded state until the user stopped the ladder - "change parameters, don't stack errors" - rolled back to the last good checkpoint and audited the target geometry firststop-stacking-roll-back-and-audit
    Observed oncerecoveryprocessprocessfork-selectionattribution

    When successive rungs each start from the previous rung's output and the target symptom does not move, stop, roll back to the last good checkpoint and re-derive the next change from an audit; keep the measurements, discard the stacked remedies.

    Symptom

    After the real-robot splits, the V2.7 ladder tried to widen the stance: a term swap (A), a new stance knife (b), more iterations (甲), a doubled weight (乙). Stance barely moved while hip yaw ratcheted 46.7 -> 49.9 -> 52.5 deg toward its 60 deg limit.

    Context

    Each rung started from the previous rung's output. The user ruled on 2026-08-11 that things had gone wrong from V2.7-A: go back to v2_6 and rethink which parameters to change instead of stacking errors.

    Change

    乙 was killed at start and not counted; the product baseline rolled back to v2_6c model_29399; every measurement and law learned on the ladder was kept ("the data is real; what stacked was the treatment"). Before any new training, a zero-training kinematic audit of the stance targets was run.

    Outcome

    The audit found the stand_pose target itself rewarding the narrow stance (pose-target-geometric-audit) and showed geometrically why the yawed stance could not be widened with flat feet - so 乙 was proven unnecessary without running it. The next in-lineage attempts still failed, which is what established that the stance is set by the get-up path.

    Mechanism

    A rung continued from a degraded state inherits its compensations, so each new fix answers the previous fix's side effects; the yaw ratchet was the visible trace of that stacking.

    Applies when

    • three or more corrective rungs in a row without progress on the target metric
    • a side-effect metric ratchets in one direction across rungs
    • a new rung is being planned from the latest (not the best) checkpoint
    “用户裁:"从 V2.7-A 开始就出问题了,应该回到 2.6 再思考如何改变参数而不是 错误叠加。"认账:A 的补丁 → b 的新刀 → 甲的加时 → 乙的加权,每级都从上级 的**退化状态**续(yaw 46.7→52.5° 的棘轮就是叠加痕迹)。 … 数据是真的,叠加的是处置。”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §44 方法论裁定(2026-08-11,用户):V2.7 全阶梯叫停,回滚 v2_6
  • Close a question with an audit, then freeze the wording - later symptoms may not reopen it without new hard evidencefrozen-verdicts-semantic-boundaries
    Mechanism understoodomniprocessprocessattributionplant-calibration

    When an audit closes a hardware-vs-policy question, record the closing evidence, freeze a citable wording for future recurrences, and set the reopening bar explicitly; separate robustness perturbations from plant-truth questions so a DR rung's failure can never silently reopen a closed measurement.

    Symptom

    Recurring directional bias on the robot kept re-suggesting "maybe the hardware/COM/mechanics are asymmetric", threatening to re-litigate questions that audits had already closed - burning attention each time a descendant policy leaned or drifted.

    Context

    Two boundary decisions were written as permanent: (1) semantic separation - "S2④ COM ±20mm = 纯鲁棒性扰动,不再承担「解释真机后仰」任务" - if the COM-DR rung degrades, the ONLY allowed conclusion is "policy insufficiently robust to COM uncertainty"; reopening "is the CAD COM wrong" is forbidden because the mass audit was completed and closed (@63f9212). (2) a frozen wording for chirality, to be quoted verbatim whenever left/right bias appears in later rungs: observed directional bias = policy-level spontaneous symmetry breaking; plant asymmetry = no supporting evidence after the mass + model symmetry audit; mitigation candidate pi_sym queued, not blocking. The evidential basis was quantitative: the root policy was perfectly symmetric under +/-6 N*s pushes (40/40) while descendants broke (17/40, 13/40) - "手性是 S2 训练中获得的, 根没有; 机械侧已双 PASS 关案, 不重开".

    Change

    Closed questions carry (a) the audit commit that closed them, (b) a frozen citable wording for recurrences, and (c) an explicit evidence bar for reopening ("无新硬证据不得重开").

    Outcome

    Later chirality observations (C2's 15 pp turn gap, hip_roll drift bias) were handled as policy-lineage properties with policy-side mitigations, without a single hardware re-audit cycle.

    Mechanism

    Symptom classes recur under different guises; without a frozen verdict each recurrence re-runs the same expensive investigation and risks a different (worse-informed) conclusion. Freezing verdict plus wording converts recurring symptoms into citations, while the evidence bar keeps the closure honest rather than dogmatic - the root/descendant symmetry comparison is what makes "it's the training, not the machine" checkable at any time.

    Applies when

    • a recurring symptom keeps suggesting an already-audited hardware cause
    • writing conclusions for a completed calibration/audit
    • a DR rung's degradation invites re-measuring the plant
    “若 S2④ 退化,结论只能是「当前 policy 对 COM 不确定性不够鲁棒」,不得重开「CAD COM 是不是错了」… 手性冻结表述 … Plant asymmetry: no supporting evidence after mass + model symmetry audit … 无新硬证据不得重开机械不对称”
    train/OMNI_V0_SPEC.md § 4. 语义分界与手性冻结表述(2026-08-07 用户定,永久)
  • No parameter tuning on the floor - a failing config retries once, then it is out; anomalies go back to simno-field-tuning-protocol
    Replicatedomnireal-deployreal-acceptanceprocesscontract-freeze

    Hardware time is for executing and measuring the pre-registered matrix, never for tuning: failing configs get one retry then elimination, anomalies get recorded and reproduced in sim, and contract-check bypass flags stay unused.

    Symptom

    Hardware sessions create pressure to fix problems live - nudge a gain, tweak a scale - which destroys attribution and risks the robot.

    Context

    The anomaly-handling section of the acceptance sheet is three fixed plays: (1) falls at start -> retry once at the same settings; falls again -> that configuration is eliminated, "不现场调参" (no on-site parameter tuning); (2) limit cycle or motor screech -> stop immediately, record the gain level and the joint, reproduce in sim before any discussion; (3) systematic disagreement with sim -> record it as a finding (hardware outranks sim) rather than adjusting anything to force agreement. Related guardrails elsewhere in the sheet: never pass --allow-unstamped / --allow-plant-drift to bypass manifest checks - if it errors, something real is wrong, stop and look.

    Change

    Field sessions restricted to executing the pre-written matrix; every fix path routed through sim reproduction and the normal config/rung process.

    Outcome

    Sessions stayed interpretable (each run matched a documented config) and safety overrides never became habit; anomalies arrived back in sim as reproducible cases instead of half-remembered floor stories.

    Mechanism

    Field-tuned values are measured under adrenaline on one floor with no logging or baselines - they contaminate the config lineage and are unattributable afterwards; and every bypass flag that skips a contract check converts a designed safety property into an operator promise.

    Applies when

    • a config fails or oscillates during a hardware session
    • someone reaches for a live gain tweak or a bypass flag
    • writing the anomaly-handling section of a deployment runbook
    “起步即摔 → 换档重试一次, 仍摔则该档出局, 不现场调参。出现极限环/啸叫 → 立刻停, 记录档位与关节, 回 sim 复现再议。… 不要给 --allow-unstamped / --allow-plant-drift —— 三枚 ONNX 都已盖章 … 真要报错说明有别的问题, 停下来看。”
    train/REAL_RUN_S2.md § 4. 异常处置
  • Real robot walked at half the sim clock for two generations - resolved by racing a reward-side and a plant-side evidence line, not by guessingperiod-doubling-evidence-race
    Observed oncewalkattributionattributionactuator-modelingplant-calibrationprocess

    For a hardware-only pathology, refuse to guess: pre-register one probe per side of the sim2real boundary (can the reward mechanism change it on hardware? can fitted plant parameters reproduce it in sim?) and let the first positive result direct the next version.

    Symptom

    The number-one sim2real gap: on hardware v6/v7 stepped at 1.23-1.32 Hz - almost exactly half the 2.50 Hz gait clock they were trained and simulated at; sim never reproduced it, two generations running.

    Context

    Instead of committing training budget to a guess, v8 pre-registered two mutually controlled evidence lines and kept the clock OUT of the training variables: (a) reward-side - if the v8 saturation fix revives joint_pos_ref (the term that pins the gait to the clock), re-run hardware and see whether frequency returns to 2.5 Hz (hypothesis: v7's frozen actions meant NO reward was pinning the gait to the clock, and the real plant - with armature and friction making high frequencies expensive - slid down to the leg's pendulum natural frequency ~1.1 Hz); (b) plant-side - record suspended joint data (fit_actuator), fit armature/friction, load the fitted values into sim2sim and see whether the 1.25 Hz reproduces IN SIM. Decision rule fixed in advance: "谁先给出阳性结果谁定 v9 的方向 (奖励侧 vs plant 侧)" - whichever line goes positive first sets the next version's direction.

    Change

    Period-doubling excluded from the v8 change set; both diagnostic lines scheduled in parallel as non-blocking work; frequency reported factually in acceptance with no pass/fail attached ("倍周期是否消失 不设判定,它是 §9 的关键证据").

    Outcome

    The gap was routed into a decisive-experiment structure rather than a speculative retrain; the plant-side line pointed at exactly the unmodeled armature/friction that were later measured and installed as the plant baseline. Resolution (era-2c full-plant retest): the family had TWO causes - v8's low-speed period-doubling vanished once measured armature+friction were installed (1.30 -> 2.50 Hz, bifurcation-edge machine sensitivity), while v7's stood untouched at 1.20 Hz (saturation-freeze-driven policy property) - both evidence lines paid off, one per case.

    Mechanism

    A behavior appearing only on hardware has candidate causes on both sides of the sim2real boundary; changing training to fix it tests only one side per expensive cycle. Two cheap parallel probes - one intervening on the reward mechanism, one making sim reproduce the real behavior - localize the cause to a side before any training money is spent, and sim-reproduction of a real pathology is itself the strongest form of plant validation.

    Applies when

    • a gait pathology appears on hardware but never in any simulator
    • deciding whether a sim2real gap is reward-side or plant-side
    • tempted to change the gait clock/reward to chase a hardware symptom
    “倍周期(真机 1.23~1.32 Hz ≈ 时钟一半,v6/v7 连续两代;sim 从不出现):两条证据线互为对照——(a)… 真机重跑看频率是否回 2.5 Hz(假说:v7 没有任何奖励把步态钉在时钟上,真机 plant 有 armature/摩擦、高频贵,自由滑落到复摆自然频率 ~1.1 Hz);(b)真机吊挂录 fit_actuator.py … 看能否在仿真里复现 1.25 Hz。谁先给出阳性结果谁定 v9 的方向。”
    train/WALK_V8_SPEC.md § 9. 平行线 (倍周期)
  • Fall recovery was defined as the whole chain - any fallen pose, a stable stand, a clean hand-back to walking - and built as a second policy behind a deploy-side switch, not folded into the walking PPOrecovery-two-policies-and-a-state-machine
    Observed oncerecoveryprocessprocesscontract-freezereal-acceptance

    Define a recovery skill by the whole chain it must complete, including the hand-back to the next controller; if it is built as a separate policy, make the switching logic and its handoff contract a deliverable of their own, and keep the recovery observation contract a subset of the locomotion one so a unified policy stays possible later.

    Symptom

    A walking robot that falls needs a human to stand it back up. The design question on 2026-08-09 was whether to teach getting up inside the existing omni walking policy or beside it.

    Context

    The user set the goal as "any fallen pose -> stand up alone -> stand stably", and the spec named the real difficulty as the full chain fall -> recovery -> stable stand -> correctly initialised walking history and clock -> walking, making the deploy state machine a first-class deliverable. A unified single policy had a real-robot precedent (arXiv:2605.18611, a state-dependent gate near 37 deg tilt) but was deferred until a recovery policy and an omni policy were each reliable. The line ran on its own branch and worktree with every walk/stand/omni/run config path untouched. The development path copied the G1 learned get-up logic (arXiv:2502.12152): first find any feasible get-up (ugly accepted), then add smoothing, torque and real-robot constraints. The recovery contract kept the base 45-dim observation (command slice held at 0, no gait phase, no frame history - their reasons do not apply to a skill without a clock or a velocity task), so it stays a prefix of the 215-dim omni contract and a later merge is not foreclosed.

    Change

    Two policies and a deploy-side switch instead of one retrained walking policy; recovery got its own minimal contract (45 dims, full-range action, later the beta-anchored profile) and its own acceptance battery.

    Outcome

    The split held for the whole line: on 08-14 deploy_policy gained a second (PolicyIO, ONNX) pair behind --recovery-policy, each loaded under its own manifest contract, and the runbook runs stand_v1b or omni_c4_ff800 as the locomotion side with recovery_v3_1p1c. The literature scan of 08-10 found that every verified get-up implementation deploys one end-to-end policy (or softly gated experts) and stages only on the training side - so the runtime state machine here is the walk/recovery switch, not a staged get-up.

    Mechanism

    A separate policy keeps each reward table single-purpose and lets a proven walking lineage stay byte-frozen; the cost moves to the handoff, where every piece of state one policy leaves behind (history, clock, last action, command) must be reset for the other.

    Applies when

    • adding fall recovery or get-up to a robot that already walks
    • choosing between one unified policy and a switched pair of policies
    • designing the observation/action contract of a secondary skill
    “先做 recovery policy + omni policy 两个策略,部署侧状态机切换;不把 recovery 硬塞进现有 omni PPO。 … 任务定义:**任意跌倒姿态 → 自己站起来 → 稳定站立**。真正的难点不只是"起身", … omni walk**(§6 部署状态机是本 spec 的一等公民,不是附录)”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §0 目标口径与架构判决(用户 2026-08-09 定)
  • A walking policy's tilt cutoff is a legal state for a recovery policy - the default 45 deg fall guard had to be raised for recovery tests and is disabled once the switch owns falls, so the abort chain becomes the recovery timeout, the operator's cut, and the firmware torque limitsfall-guard-becomes-a-state
    Observed oncerecoveryreal-deployreal-acceptancehardwareprocess

    When a new skill makes a safety cutoff's trigger a legal state, replace the cutoff with a bound of the skill's own (a timeout ending in a safe stop) instead of just switching it off; keep the operator's cut and the firmware limits as independent layers, and write every flag change into the run sheet.

    Symptom

    deploy_policy's default protection stops the robot beyond 45 deg of tilt. A recovery policy starts lying at roughly 90-97 deg, so under the default it is refused on the spot - a flag the first hanging checklist forgot.

    Context

    The layers in the sources: deploy_policy's tilt cutoff (default 45 deg, a line in the safety chain); for standalone recovery tests the cutoff was raised (110 deg in the spec's A/B sheet; 181 deg, effectively off, in some runbook commands); with --recovery-policy the cutoff is disabled because a fall is now a state, not an exception, and RECOVERY lasting over 15 s ends in a safe stop (the runbook calls it the line where the spotter steps in). Independent of the policy: firmware torque limits checked at start (12/17/11 N*m, set_torque --check), the operator cutting enable at any kicking or oscillation, and in the one-leg teleop a space-bar stop that puts the foot down.

    Change

    The flag was added to the run sheets, and the FSM replaced the removed cutoff with its own bound (the timeout).

    Outcome

    The spec records the flag omission and its fix; it does not record the FSM's timeout being exercised on hardware.

    Mechanism

    A safety cutoff encodes one policy's notion of "abnormal"; a new skill whose normal operation lies beyond it either cannot run or runs with the cutoff off, and only a replacement bound keeps the chain closed.

    Applies when

    • deploying recovery, fall-damage or acrobatic skills behind existing safety checks
    • a run sheet disables a protection flag
    • listing the abort chain for a hardware session
    “--max-tilt-deg(默认 45°,安全链第 13 行写的那个)。recovery 的合法状态覆盖整个倾角域,把它抬到 181 = 实效关闭 … RECOVERY 超时 15s 会自动安全停(看护介入线)”
    RL系统/FOLLOW THIS copy 2.md § FSM 吊挂首测 ② 落地测 / #### Recovery Policy (operator runbook, undated)
  • A field experiment is allowed when it is pre-scripted, single-variable, and self-reversing (RAM-only writes)reversible-single-variable-field-experiments
    Observed oncewalkreal-deployhardwarereal-acceptanceprocessattribution

    Permit hardware-side experiments only when scripted in advance with one variable, a log, and automatic reversion (volatile writes, git restore); keep every config mirror (yaml vs firmware) changed and restored as a unit.

    Symptom

    A hypothesis needed a hardware test - v5's "wild kicking" might trace to the RS00 torque cap being deployed at 11 N*m vs its trained 14 (-21%), on exactly the ankle-roll/hip-yaw joints doing lateral-yaw work - but changing limits in the field is the classic way to lose track of robot state.

    Context

    The experiment was written to be safe by construction: change exactly one number (robot.yaml RS00 tau_limit 11.0 -> 14.0), write to firmware RAM only (--write without --save, so a power cycle automatically rolls back to the saved 12/17/11), run the single logged trial, then restore both yaml (git checkout) and RAM immediately. The consistency requirement is explicit: the deploy tool's torque self-check compares against robot.yaml, so yaml and firmware must change and restore together; and the hypothesis scoping is itself single-variable - RS06's 67% cut was measured irrelevant (gait uses only 16% of rated) and hip torque was left alone for safety.

    Change

    Field experimentation policy refined: not "never touch hardware settings" but "only pre-scripted, one-variable, logged, auto-reverting changes with config/firmware kept consistent".

    Outcome

    The sub-experiment could answer the torque-cap hypothesis without any risk of the robot persisting in an undocumented state - forgetting to restore costs nothing but a git checkout.

    Mechanism

    The danger of field changes is state divergence (robot config drifting from the repo's record), not the change itself; volatile (RAM-only) writes bound the divergence lifetime to one power cycle, and single-variable scoping preserves attributability even in a field setting.

    Applies when

    • a hypothesis requires changing firmware limits or gains on the robot
    • field debugging tempts persistent config writes
    • designing safe escape hatches for deployment tooling
    “程序(--write 不带 --save = 只写 RAM,断电自动回滚)… deploy 的限扭自检是对 robot.yaml 比对的,所以 yaml 和固件必须同改同还原;忘了还原也没事,断电重启即回 12/17/11(上次 --save 的值),但 yaml 要 git checkout。”
    train/REAL_SWEEP_V5_V8.md § 4. 限扭子实验(可选二期,只对 v5,单变量)
  • Removing a foot-spacing wall passed every simulated gate and made the feet collide on the real robot - nothing priced stance width in the two-foot phase, the policy narrowed to the simulator's self-collision floor, and real calibration offsets closed the last millimetres; the wall came back with a gateremoved-wall-returns-on-hardware
    Observed onceonelegreal-deployreward-shapinggate-batteryreal-acceptance

    When a constraint is removed, name what will govern that quantity instead and add a gate for it; never let a simulator's collision floor be the margin, and when a gate is exceeded by a hair, record the exact numbers and hand the release decision to a person instead of quietly passing it.

    Symptom

    On the first real-robot try of oneleg_v0 (2026-09-16) the two feet collided; the user also judged the folded foot not high enough.

    Context

    The V0 reward table had dropped the feet_lateral_distance wall because it seemed to conflict with the hip adduction single support needs. In the two-foot command bucket no remaining term governed stance width, so the policy drifted narrower until the simulator's self-collision stopped it; the sim acceptance had no foot-spacing gate, so 40/40 said nothing about it. On the robot, calibration offsets consumed the margin.

    Change

    V0.1: the wall restored (-10, minimum 0.16 m), re-checked against measured numbers (a swing-phase lateral spacing of ~148 mm costs 0.12 per step, acceptable); fold weight 0.8 -> 2.0; a ninth gate: minimum foot spacing >= 100 mm and zero leg-contact frames. The removal was kept on record.

    Outcome

    oneleg_v0_1 (V0r2 model_2200) passed 39/40 with the spacing gate 40/40. The single miss (a 15.4 deg tilt transient against a < 15 deg limit during a side switch, steady 6.9 deg, everything else green) was recorded with its numbers and released for the user to overrule.

    Mechanism

    An unpriced degree of freedom drifts to wherever the simulator stops it; if that stop is the simulator's own collision model, the policy's margin on hardware is whatever the calibration error leaves.

    Applies when

    • dropping a reward term that looked redundant or conflicting
    • hardware shows a failure no simulated gate measures
    • a release candidate misses one gate row by a small amount
    “V0 撤墙被真机证伪(2026-09-16):双脚桶没有任何项管站宽,策略贴 sim 自碰撞底线收窄,真机标定偏差一吃**双脚相碰**。 … min ≥ 100 mm 且腿碰 0 帧(eval_straight 同判据)—— … V0 真机双脚相碰暴露 sim 门未看脚距的缺口 … L s2 标称 tilt 瞬态 15.4°(门限 <15, 超 0.4°, 稳态 6.9°, 该跑其余全绿)——换侧瞬态蹭线, 判定放行留档, 用户可否决。”
    git:Lucen V2@origin/oneleg-line:train/ONELEG_V0_SPEC.md § §4 feet_lateral_distance 行 / §6 验收门 ⑨ / §8 核查单 7
  • A sim veto needs real confirmation too - the worst sim cell was scheduled as the most informative hardware runsim-veto-needs-real-confirmation
    Mechanism understoodomnireal-acceptancereal-acceptancesim2simattributionprocess

    Never let sim alone both condemn a purpose-built configuration and escape audit: spend one cheap, safeguarded hardware run on the condemned cell, pre-registering what agreement and disagreement would each imply about the proxy.

    Symptom

    The fric-2400@kd1.0 combination was sim's worst cell across the board (survival 17/20 - the only miss, mu0.4 1/20, push 103/160, zero-cmd 2/20), yet it was the only product specifically trained for the kd1.0 deployment gain - discarding it on sim evidence alone would leave the sim's own validity untested exactly where it mattered.

    Context

    The team had been burned in the other direction before ("Isaac 指标三次 零预警" - training-side metrics gave zero warning three times), so the symmetric rule was written: sim's rejection also needs hardware confirmation ("sim 判被支配 ≠ 真机被支配 … sim 的否决也要真机确认"). The run was pre-registered with a dual reading: real matches sim -> the S2f ladder closes and the fork root is settled; real clearly better than sim -> the MuJoCo proxy has a systematic bias in the kd1.0/low-margin region, "那比选型本身重要得多" - and every S2f sim acceptance would need re-scoring.

    Change

    The condemned configuration was kept on the hardware roster (last, spotted, minimal exposure) explicitly as a proxy-validation probe, not as a deployment candidate.

    Outcome

    Session design captured either result as progress: selection confirmed, or a proxy bias discovered that would re-price the whole ladder's verdicts.

    Mechanism

    Every sim verdict is a joint statement about the policy AND the proxy; cells where a policy was purpose-trained for the exact condition sim condemns are where proxy error is most likely and most costly. Testing the veto converts a selection decision into a calibration measurement of the evaluator itself.

    Applies when

    • sim rejects the configuration that targets the actual deployment condition
    • the eval proxy's calibration has never been checked in that regime
    • deciding which hardware runs are worth their risk
    “但它也是唯一为 kd1.0 部署档专门训的产物 —— sim 判被支配 ≠ 真机被支配, 「Isaac 指标三次零预警」的教训反过来同样成立: sim 的否决也要真机确认。… 若真机明显好于 sim → MuJoCo 代理在 kd1.0/低裕度区有系统性偏差, 那比选型本身重要得多。”
    train/REAL_RUN_S2.md § 上机名单 note / 2. sim 侧预注册预期 ⑤
  • Order hardware runs by sim risk, gate each stage on the last, and put the fragile cell last with a spotterrisk-ordered-real-deployment
    Replicatedomnireal-deployreal-acceptanceprocess

    Script hardware sessions as a risk ladder: baseline first, sim-riskiest last with a spotter, suspended smoke before ground, each stage gated on the previous, environment (floor mu) recorded as a selection input - and stop at the stage that misbehaves.

    Symptom

    Five policy-x-gain combinations had to go on hardware in one session, with sim survival ranging from 20/20 down to 17/20 (and zero-command survival down to 2/20) - an unordered session risks breaking the robot on an avoidable run.

    Context

    The execution sheet fixed the order as sim-risk low to high, control baseline first (current SOTA establishes the floor reference), the fragile cell (fric-2400@kd1.0) last with a person spotting throughout. Stage gating: suspended smoke (feet off ground, 10 s each, all five pass before anything touches down) -> suspended with IMU and forward command (gait forms in the air) -> grounded runs -> speed raise only for combos that survived the previous stage -> zero-command tests only with a spotter, ordered by sim zero-cmd survival, with the 2/20 cell skipped by default. Preconditions include recording the floor material and estimating mu (if mu <~0.6, sim says pick the kd1.2 gain as main), port/CAN self-check, calibration frozen. Any stage failing stops the session at that stage: "任一段出问题就停在那一段, 不要跳到下一段".

    Change

    Session structured as a risk ladder with per-stage gates instead of a flat checklist; per-combo sim survival numbers written into the run table as the ordering key.

    Outcome

    The session design localized any failure to the cheapest stage that could reveal it, kept the robot safe for the informative fragile run, and made the control baseline available before any comparison run.

    Mechanism

    Hardware sessions consume a shared budget (robot integrity, battery, floor time); ordering by predicted risk means information is bought cheapest-first, and stage gates convert an expensive failure into a cheap earlier one. Baselines run first because every later reading is relative to them.

    Applies when

    • taking multiple policies/configs to hardware in one session
    • a candidate is known-fragile in sim but must be measured
    • writing a deployment runbook for a new robot
    “跑序 = sim 风险从低到高, 最险的放最后 (依据 = 存活门/零指令存活) … ⑤ 是 sim 里最脆的一格 … 放最后跑, 全程留人扶, 起步即给 cmd, 零指令不做。… 任一段出问题就停在那一段, 不要跳到下一段。”
    train/REAL_RUN_S2.md § 上机名单 / 全部命令
  • Pre-register the ladder's risks and how each future result will be read - before trainingpreregister-risks-and-fork-readings
    Replicatedomniprocessprocess

    Before a training ladder or risky rung, write the risks, the stop rules, and how every plausible outcome will be interpreted - then do not edit them after seeing results.

    Symptom

    Without pre-registration, ladder results get rationalized after the fact; the team had already seen post-hoc reads go wrong and adopted written pre-commitment.

    Context

    The C-ladder execution sheet opens with three numbered pre-registered risks: (1) S2 plant robustness will not carry into omni - a full S2 redo is budgeted from the start; (2) the s1e recipe has a collapse valley at iter 1500+ (recorded twice), so every rung runs a watch_ckpt --every 100 smoke loop with stop-on-degradation; (3) the root's OOD survival edge may partly be "it is slower / commits less" - with the reading fixed in advance: if C1 training raises tracking while survival drops, the edge was bought with slowness, and root selection reopens. Later rungs went further, pre-registering a full result-to-conclusion table for the A/B arms ("预注册读法(事后不改)") and even pre-registering the author's own doubt that a level would fail and what its failure would prove.

    Change

    Standing practice: before each rung, write down (a) known risks with their mitigations, (b) the interpretation of each possible outcome, (c) stop criteria - all frozen before the run starts ("开训前写死,事后不许改").

    Outcome

    When arm-A/arm-B and redo results arrived, conclusions were read off the pre-registered table instead of argued; a predicted-likely-FAIL level (C4-redo3) was still run because its pre-registered value was eliminating the regularization hypothesis - which it did.

    Mechanism

    Pre-commitment converts each training run into a decisive experiment: outcomes falsify or confirm named hypotheses instead of being absorbed into a story; it also makes negative results valuable (a FAIL that eliminates a hypothesis advances the search).

    Applies when

    • launching a multi-rung training ladder
    • running an A/B fork whose outcome will drive a fork/root decision
    • a rung is expected to fail but is run for its diagnostic value
    “三条预注册风险 … 若 C1 训后跟踪提上去而存活掉下来,说明这条优势是速度买的、不是通用性 → 那时重开选根。”
    train/C_LADDER_RUN.md § 0. 三条预注册风险
  • Prove an armless get-up exists before training it - a connected static domain, 25% torque on the cheapest path, an 8 mm hand-over gap, a static roll-over - and write down what each scan cannot representget-up-feasibility-accounts-before-training
    Mechanism understoodrecoveryplant-calibrationplant-calibrationhardwareprocess

    Before training a get-up or any multi-contact skill, compute the quasi-static accounts - connectivity of the static domain, torque along the cheapest path, hand-over gaps, COM shift available for rolling - and state which configurations each scan cannot represent; when a policy gets stuck in one of those, extend the scan before blaming the reward.

    Symptom

    A torso-and-legs robot has no arms to push off the ground; whether it can get up from the floor at all was unknown when the line opened.

    Context

    recovery_feasibility.py ran three accounts before any training (the run line's "hard accounts first" discipline): a sagittal quasi-static scan (0.05 rad grid, 44,520 configurations, MuJoCo FK, flat-foot assumption). (1) The static standing domain (COM over the feet, torques in limit) has 29,586 cells, flood-fill connected with no islands, from a 0.097 m deepest squat to the 0.384 m stand. (2) The minimum-torque path peaks at 25% of the limits (knee 2.9/12, ankle 3.7/17 N*m) - a 4x margin. (3) All 508 ground-contact configurations have the contact behind the COM; the smallest gap to pure foot support is 8 mm. A roll-over account: swinging both straight legs to one side shifts the COM 96 mm against a 62 mm torso half-width - 1.6x, so rolling needs no momentum. Three conclusions were written down for later attribution: the legs are 80% of the mass (swinging them moves the COM), prone has no flat-foot hand-over face (merge into a supine/side sit first), and supine needs no sit-up (hip flexion is limited to 75 deg).

    Change

    The accounts gated opening the line and were cited in every later argument about what the robot can physically do.

    Outcome

    They held where they applied: in V1.0 every fall category was righted under a hard rate limit, which the spec records as the quasi-static roll-over account verified by training, and the 25% torque path was the basis for pursuing a slow get-up. They also misled once: account (3) is sagittal, and on 08-09 the spec corrected its scope - it cannot represent the splayed W-sit where the policy actually stalled. A follow-up prone hip-ROM scan (471,625 cells) found 3,912 two-foot-contact cells and none with both soles within 25 deg of level (best 40.2 deg): a flat-footed push-up from prone is infeasible on this robot, so the fix became where the feet go after sitting up.

    Mechanism

    A get-up needs a connected path through statically feasible configurations and enough torque along it; quasi-static accounts bound both cheaply, and momentum can only make the real problem easier. A reduced-dimensional scan, though, only speaks for the configurations it can express.

    Conflicts

    In R0.1-R0.2 the spec read account (3)'s "prone has no front hand-over" as "prone lacks the roll-over skill"; R0.3's confusion matrix showed prone had righted its torso 159/159, and the spec then restricted account (3) to the sagittal configurations it models.

    Applies when

    • opening a get-up, recovery or climbing skill on a new robot
    • a robot lacks arms or other obvious contact options
    • a policy stalls in a configuration a feasibility scan never modelled
    “本机 **torso + legs、无手臂可撑地**,开训前先证明存在不依赖手臂的物理解 … 双腿同侧直腿摆最大横移 **96 mm = 1.6×** … **静态摆腿即可翻身,无需动量**”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §1 机械可行性判决(2026-08-09,recovery_feasibility.py 三笔账)
  • Cross-simulator gate (Isaac Lab to MuJoCo) comes before any hardware attemptsim2sim-gate-before-sim2real
    Replicatedwalksim2sim-gatesim2simprocessgate-battery

    Gate every policy through a second simulator with an independently built plant before hardware; treat sim2sim failure as a contract or overfitting bug, and sim2real failure after a sim2sim pass as a plant/actuator gap.

    Symptom

    A policy that only ever ran in its training simulator carries untested dependencies on that simulator's solver, contact model, and defaults; the first place those dependencies surface should not be the real robot.

    Context

    Standing order of operations for the whole Lucen program, recorded as the opening line of the experience log: train in Isaac Lab, gate in MuJoCo, only then go to hardware. The MuJoCo side is the same plant used for evaluation batteries, so a sim2sim pass also validates the exported policy + contract (obs ordering, scales, defaults) outside the training stack.

    Change

    Pipeline rule adopted - every checkpoint must pass the MuJoCo evaluation battery (sim2sim) before it is considered for real deployment (sim2real).

    Outcome

    Used generation after generation as the cheap filter; hardware sessions only ever received policies that had already survived a second simulator.

    Mechanism

    Two simulators disagree exactly where a policy is overfit to simulator-specific artifacts (contact softness, integrator, default parameters, obs conventions); a cross-sim transfer catches contract bugs and solver overfitting at zero hardware risk, so real-robot failures that remain are attributable to genuine plant/actuator gaps.

    Applies when

    • planning the path from training to first hardware trial
    • exported policy behaves differently outside the training framework
    • triaging whether a real-robot failure is contract vs plant
    “先sim2sim - 从isaaclab 到mujoco / 再sim2real”
    Experience.md § opening lines (1-2)
  • Torque caps cannot soften footfalls - impact is falling-mass momentum, only the reward can treat itlanding-impact-not-fixed-by-torque-caps
    Mechanism understoodwalkreward-shapingreward-shapinghardwareactuator-modeling

    Classify each hardware symptom by the physics that sets it: quantities fixed by ballistic momentum at contact must be treated through the policy's trajectory (reward terms on approach velocity/force), never through actuator caps - and size such penalty weights against your own tracking reward, not a lighter robot's.

    Symptom

    Footfalls slammed at 1.78x body weight in sim baseline (human walking: 1.2-1.5x); the tempting hardware-side fix was cutting actuator torque limits.

    Context

    Measured directly: scaling torque limits from x1.0 down to x0.4 left peak landing force essentially unchanged (1.75 -> 1.78x body weight) - the impact force comes from the momentum of the falling mass at touchdown, not from motor effort. The fix has to change the trajectory, i.e. the policy, i.e. the reward: feet_contact_forces penalty above a threshold of 113 N (= 1.2x the 9.58 kg robot's weight), clipped, weight -0.005. The weight was sized locally, not copied: the reference robot's -0.001 would amount to 0.9% of tracking reward on this robot ("策略不会理它" - the policy would ignore it); -0.005 gives 4.4%.

    Change

    Added threshold-type contact-force penalty (-0.005, threshold 1.2x body weight) as one of v6-minimal's three changes; hardware torque cuts explicitly rejected as a footfall treatment.

    Outcome

    Landing force 1.72x -> 1.55x by v6 (target <1.5x, missed by 3% - progress booked honestly); the torque-cap dead end was documented so it would not be retried.

    Mechanism

    At touchdown the ground stops a ballistic mass; the impulse is set by approach velocity and effective inertia, which motors can no longer influence in the final instant. Only earlier trajectory choices (approach velocity, timing) reduce it - and those are selected by the reward, not by actuator limits.

    Applies when

    • footfall impact or landing noise on hardware
    • proposals to derate torque as a softness fix
    • importing contact-force penalty weights from another robot
    “⚠️ 硬件限扭降不了落脚力 —— 砸地力来自下落质量的动量: 实测 tau ×1.0→×0.4, 落脚力 1.75→1.78× 体重纹丝不动。只有这条奖励能治。… ⚠️ 权重不能用 Pi 的 −0.001 —— 实测在我们身上只占跟踪奖励的 0.9%, 策略不会理它 (Pi 6.94 kg 更轻)。−0.005 给到 4.4%。”
    train/WALK_V6_MINIMAL.md § ③ 新增 feet_contact_forces
  • Bracket a real-robot A/B with a repeated reference run - battery drain is the confoundbattery-bracketed-real-ab
    Observed onceomnireal-acceptancereal-acceptanceattributionprocess

    Order hardware A/B sessions as A-B-A: repeat the first condition at the end, and void the comparison if the bracket runs disagree - never let battery or venue drift ride on the second condition.

    Symptom

    In a two-policy teleop A/B on hardware, the second policy is measured on a lower battery voltage than the first - a systematic bias that would be read as a policy difference.

    Context

    C2 real A/B (checkpoint 700 vs A800, same floor, same day) was scripted as 700 -> A800 -> 700-rerun, with the explicit note that a teleop session drains the pack and the trailing policy "naturally suffers".

    Change

    Protocol: run the reference policy first AND last; if the two reference runs differ noticeably, declare the whole session battery/floor-polluted and void the A/B ("结论作废重来"). Also log electricity per run.

    Outcome

    Called out as the round's only systematic confound, closed by one extra command ("这是本轮唯一的系统性混淆源,一条命令就能堵掉").

    Mechanism

    Battery voltage scales available torque, and torque loss hits behavior asymmetrically (see power-scale-hurts-nonforward-axes), so drain masquerades as policy regression; a head/tail reference pair converts the unobserved drift into a measured control.

    Applies when

    • comparing two policies or settings on hardware in one session
    • any sequential hardware evaluation where the plant drifts (battery, temperature, floor wear)
    “为什么要 700 复跑:一次遥控 session 下来电池会掉压,第二枚天然吃亏。头尾各跑一次 700,若两次 700 明显不同,说明这轮 A/B 被电量污染,结论作废重来。这是本轮唯一的系统性混淆源,一条命令就能堵掉。”
    train/C_LADDER_RUN.md § 3c. A-3 真机 A/B(同一段地板、同一天、电量记账)
  • The real robot's right-leg kicking was over-trained-delay times loop gain - irreducible pipeline latency is plant, model it fully from day onepipeline-latency-is-plant-not-dr
    Mechanism understoodomniactuator-modelingactuator-modelingreal-acceptanceattributionsim2sim

    Measure the end-to-end action pipeline delay and build it into the nominal plant and every acceptance gate from day one; treat power/scale deratings that "fix" oscillation as gain-reduction crutches flagging an unmodeled delay, and expect higher-feedback-gain policies to be MORE delay-fragile.

    Symptom

    On hardware, s1c/s1d at action scale 1.0 always kicked wildly with the right leg (s1c only ran as SOTA at power 0.8; s1d only at 0.7) - while sim showed nothing under default evaluation.

    Context

    Sim reproduced the incident item by item once the real pipeline delay was injected: s1d@1.0 with --delay 1 fell at 10.2 s, --delay 2 at 5.2 s; s1c@1.0 stressed (r_hip_roll saturation 5 -> 16%; "右脚" = the policy's chirality makes the right leg its high-gain leg); and the combos that worked on hardware (s1c@0.8+delay2, s1d@0.7+delay2) all survived in sim. Mechanism: the real pipeline is ~1-2 ticks (BusWorker next-cycle pickup + CAN round trip) but S1.1 trained only to 1 tick - "超训延迟 × 全环路增益 = 振荡;衰减 = 压环路增益换稳定" (delay beyond training x full loop gain = oscillation; the power derating had been buying stability by compressing loop gain). s1d was MORE fragile than s1c because its yaw 3-layer stack had learned higher feedback gain - higher gain, lower delay tolerance. Three changes: latency DR widened to cover reality; acceptance gates and smoke runs moved permanently to --delay 2 ("门必须在真机条件下预测 真机"); and the doctrine written twice-paid: "不可约的管线属性(延迟、 限速)不是'随机化选项',是 plant 本体,第一天就该全额建模" - S1's nominal-then-robust staging falsified by hardware for the second time. The later s1e hardware run at power 1.0 (no kicking, normal force) closed the loop: "0.8 = 旧代拐杖" - the derating had been a crutch for the under-modeled delay, not a real requirement.

    Change

    Latency modeled as plant from day one of any lineage (measured 1-2 ticks covered, bridge-layer rate limits likewise modeled by default); every gate and smoke evaluation issued under --delay 2.

    Outcome

    Kicking reproduced, explained, and eliminated in the s1e generation at full scale and full power; the deploy-side crutches (0.7/0.8) retired for the new lineage.

    Mechanism

    Feedback oscillation onset is a product of loop gain and phase lag; a policy trained below the real delay learns gains that sit past the real stability margin, and any output derating masks it by scaling gain down. Since pipeline delay is deterministic hardware property - not an uncertainty - it belongs in the nominal plant, and every evaluation must include it or the gate predicts a robot that does not exist.

    Applies when

    • hardware oscillation/kicking that sim only reproduces with added delay
    • a policy only runs on hardware at reduced power/scale
    • defining what belongs in the nominal plant vs the DR list
    “真实链路延迟 ~1~2 拍 … S1.1 只训到 1 拍——超训延迟 × 全环路增益 = 振荡;衰减 = 压环路增益换稳定。s1d 比 s1c 更脆 = yaw 三层栈学出更高反馈增益,增益越高延迟容忍越低。… 教训入账:S1「先标称后鲁棒」第二次被真机证伪——不可约的管线属性(延迟、限速)不是"随机化选项",是 plant 本体,第一天就该全额建模。”
    train/OMNI_V0_SPEC.md § 3. S1.4(真机右脚乱踢事故强制)
  • A constant-value plant rung passed every binary gate with record scores - and shipped 60% thinner posture margins that hardware exposedconstant-value-dr-overfits-margin
    Mechanism understoodomnidr-tuningdomain-randomizationreal-acceptancegate-battery

    Randomize deployment-critical axes over a narrow band spanning the measured real support - never a single value, never a fictitious tail - and report graded margin quantities (tilt margin) next to binary gates, because saturated gates rank thin-margin and thick-margin policies identically.

    Symptom

    s2_lag1 (trained at constant 1-frame latency) posted the strongest sim gate sheet in history (20/20 everywhere) yet was unstable on hardware, while s1e (trained across the full 0-3 frame band) was the every-run-stable SOTA at the same power.

    Context

    The sim autopsy (new --delay-jitter harness modeling the BusWorker's time-varying phase drift): 18 runs across constant and time-varying delays ALL survived - time variation alone does not kill - but the tilt-margin ordering reproduced hardware exactly: s1e 7.7-9.1 deg (thickest) < s2_lag1 10.7-15.0 < s1c 16.2-18.2. Attribution: constant-value training permits precise specialization to that one value; s1e's band diversity forced cross-value robustness - "恒定 1 帧训练 vs s1e 的 0~3 帧全带——分布多样性逼出跨值鲁棒,恒定值允许精确 特化" - so the constant-rung policy's margins were ~60% thinner, fine in sim's clean world, pushed over the line by real-world disturbances. Tool lesson booked: "存活门二值饱和后掩盖裕度差" - binary survival gates saturate and hide margin differences; graded margin columns (tilt-max) belong in the report. The synthesis with the opposite failure (wide tails cause drag-glide): the proposed resolution was a NARROW uniform band (0.02, 0.04) covering exactly the real 1-2 ticks - diversity inside the measured support, no tail, no single point. s1e's root selection later leaned on the same property: its full-band latency training "预装" the delay rungs and delivered "全工况稳定裕度" that survived power derating.

    Change

    DR-on-an-axis design refined to a three-way distinction: no wide fictitious tails (drag), no single constant values (thin margins), but a narrow band spanning the measured real support; acceptance reports gained graded margin columns alongside binary gates.

    Outcome

    The tilt-margin column entered the standard report; the s1e root (band-trained) carried the C ladder while the constant-value branch was archived with its three contributions credited.

    Mechanism

    Robustness margins are shaped by the diversity of the training distribution, not just its support: a point-mass distribution lets the optimizer trade margin for on-point performance, while a band forces solutions that keep margin across the band - and binary survival metrics cannot see the difference until the margin is spent on hardware.

    Conflicts

    The narrow-band (0.02,0.04) resolution was a pending recommendation ("裁决建议(待用户)") at the time of writing; the lineage instead moved root to s1e whose full-band training predated the staged ladder - the deterministic-staging card and this card record the two failure modes the final design must avoid simultaneously.

    Applies when

    • a rung trained at a fixed plant value aces sim but wobbles on hardware
    • binary acceptance gates are all saturated across candidates
    • choosing between constant, banded, and wide DR on one axis
    “18 跑全活,时变性单独不足以击杀;但 tilt_max 裕度排序完整复现真机:s1e 7.7~9.1°(最厚)< s2_lag1 10.7~15.0 … 恒定 1 帧训练 vs s1e 的 0~3 帧全带——分布多样性逼出跨值鲁棒,恒定值允许精确特化 … 存活门二值饱和后掩盖裕度差(s2_lag1 sim 门 20/20 史上最强却真机不稳)”
    train/README.md § s2_lag1 真机不稳 × s1e 稳的 sim 对拍(2026-08-07,时变延迟实验)
  • Two machines, one configuration - every gain, offset and torque limit changes only in robot.yaml, whoever edits pushes at once, both checkouts show the same commit before the robot moves, and a pulled policy file is size-checked and synced before power-offtwo-machine-config-discipline
    Observed onceinfrareal-deployprocesshardwarecontract-freeze

    Treat the robot's configuration as a versioned artifact with one source of truth, push every change immediately, verify identical commits on every machine before a hardware session, keep hardware limits in the repo and the firmware in sync in both directions, and verify transferred model files (size, digest) before running them.

    Symptom

    The robot's onboard computer runs the bridge and deploy scripts from its own checkout while training and analysis happen on other machines; a hot fix left on one side, or a half-written file, silently makes the robot run something other than what was evaluated.

    Context

    The operator runbook's "wall version" of the two-machine discipline: configuration changes only in robot.yaml (calibration offset/sign, gains, torque limits), committed and pushed from the Mac, pulled on the robot, bridge restarted; code is not edited on the robot, and if it is, it is committed and pushed on the spot - nothing unpushed overnight; 30 seconds before every real-robot session both checkouts must show a clean status and the same last commit hash; changing tau_max requires writing the motor's limit_torque too (and the reverse); re-zeroed motors require re-measuring offsets. The recovery line added: after pulling on the robot, check the ONNX is not zero bytes (a lesson from a corruption incident on 08-12) and sync before cutting power; the recovery and main lines are separate worktrees, each pulled with --ff-only.

    Change

    Operating rules, pinned on the wall and repeated in the hanging checklists ("git pull, both machines on the same commit").

    Outcome

    The sources record the rules and the incident that produced the size check; they do not record a count of sessions the rules caught.

    Mechanism

    A policy is evaluated against one configuration; any divergence between the machines, or a truncated file, turns a hardware result into a result about an unknown configuration.

    Applies when

    • a robot's onboard computer and a workstation both hold the configuration
    • someone hot-fixes code or gains on the robot
    • model files are copied or pulled to the robot before a session
    “改配置只改 robot.yaml(标定 offset/sign、增益、限扭全在里面)→ Mac git commit + push → NX git pull → 重启桥。 … 谁改完谁立刻推,永远不留未推送的改动过夜。 … 每次上真机前 30 秒检查:两边 git status 干净、git log -1 哈希一致。 … 铁律不变:改 tau_max 必须同步写电机 limit_torque(反之亦然);电机重新标零后 offset 必须重测回填 yaml。”
    RL系统/FOLLOW THIS copy 2.md § ② 双机维护纪律(贴墙版)
  • Changing the gait clock silently flipped a hardwired threshold's meaning - write derived constants as expressionsderived-constants-must-track-their-base
    Mechanism understoodwalkprocessprocessreward-shapingcontract-freeze

    Before changing any base parameter (clock, control rate, scale), enumerate every constant derived from it and every constant that must NOT change; convert derived literals into expressions of the base so the next change cannot silently flip a term's meaning.

    Symptom

    Slowing the clock 0.40 -> 0.50 s would have silently inverted the feet_air_time threshold's semantics: the 0.25 s threshold was hardwired, so at ct 0.40 the swing window (~0.20 s) sat below it (constant pressure to lengthen strides), while at ct 0.50 the window (~0.25 s) equals it - the term's meaning flips from "push longer" to "neutral" with no code error anywhere.

    Context

    The clock change audit walked every dependent quantity: most followed automatically (joint_pos_ref / clearance / contact_number cycle_time params, gait_phase observation, deploy/sim2sim/policy_io, export) - wiring confirmed, zero hand edits; the air_time threshold was the one hardwired constant, fixed by preserving the RATIO: 0.25 -> 0.3125 = 0.625 x ct, with the recommendation to commit it as the expression 0.625*ct "一劳永逸" (solved once and forever). The same audit also listed what must NOT follow the clock (50 Hz control rate, physics dt/decimation, 47-dim contract, action_latency absolute seconds, PD/torque limits) - the change's blast radius stated in both directions.

    Change

    feet_air_time threshold re-expressed as a fraction of cycle_time; auto-following vs must-not-change lists written into the spec for the clock migration.

    Outcome

    The clock migration (v10, repeated in v11) carried no silent semantic flips; the expression form removed the trap for every future clock change.

    Mechanism

    Constants derived from a base parameter encode a ratio at their birth; storing the evaluated number severs the dependency, so changing the base leaves stale semantics with no failing test. Expressions preserve the intent; and an explicit both-directions dependency list (follows / must-not-follow) is what makes a base-parameter change reviewable.

    Applies when

    • changing gait clock, control frequency, or units
    • a reward threshold interacts with a phase/window duration
    • config audit finds literals that encode ratios
    “feet_air_time 阈值 0.25 是写死的,不跟 ct 走——0.40 时摆动窗 ~0.20s<0.25(恒拉长压力),0.50 时摆动窗 ~0.25s≈阈值(语义翻转)。按比例保原压力:0.25 → 0.3125(=0.625×ct;建议直接写成 0.625 * ct 表达式,一劳永逸)。”
    train/WALK_V10_SPEC.md § 3. T —— 慢时钟 (训练侧必做一件)
  • Diagnose a behavior failure by enumerating hypotheses and auditing each against the actual config, cheapest firsthypothesis-table-code-audit
    Replicatedwalkattributionattributionprocessreward-shaping

    Before changing anything, write the full hypothesis list for the symptom and audit each against the resolved config and measured magnitudes, cheapest check first; train only on the survivors.

    Symptom

    Real robot leaned forward "wanting to walk" but dragged its feet instead of lifting them - a symptom with many plausible causes and no obvious single fix.

    Context

    Seven hypotheses were listed and each checked against the actual training config files (velocity_env_cfg.py, isaac_values.py), ordered by check cost: missing foot clearance term (CONFIRMED, primary - feet_air_time existed but no swing-height term at all); energy penalties dominating (REJECTED - energy terms total -0.19 vs tracking +1.2, 16%); command range too narrow (CONFIRMED - (0.15,0.35)); nominal pose too crouched / action scale too small (HALF - knee 0.5 rad = 28.6 deg deep, scale fine); mixed PD across motor types (REJECTED - already grouped); missing base-height reward (REJECTED - present at -5.0); height-drop termination (REJECTED - none exists, which itself became finding #4 of the fix list).

    Change

    The audit produced a ranked fix list (add clearance penalty; widen speed range; reduce nominal crouch) with each rejected hypothesis documented so it would not be re-litigated.

    Outcome

    Three confirmed causes fixed over v5/v6: swing height went 22-23 mm -> 34 mm, tracking 81% -> 87%; the rejected hypotheses stayed rejected (no wasted rungs on energy weights or PD grouping).

    Mechanism

    Multi-cause symptoms invite guess-and-train loops; a written hypothesis table forces each candidate to be confirmed or rejected against actual values (not impressions), and cost-ordering the checks means most hypotheses die for the price of reading a config.

    Applies when

    • a real or sim behavior failure has multiple plausible causes
    • the team is about to "try a fix" without an audit
    • post-mortems keep re-proposing already-rejected causes
    “真机现象:躯干前倾像要走,脚抬不起来(拖着蹭)。按成本从低到高逐条核查 … | 1 | 缺 foot clearance | ✅ 成立,首要 | 有 feet_air_time,无任何摆动足高度项 | | 2 | 能量惩罚压过跟踪 | ❌ 不成立 | 能量类合计 −0.19,跟踪 +1.2,只占 16% |”
    train/WALK_DIAGNOSIS.md § walk 拖地问题 — 七条假设的代码核查结果
  • Low-friction robustness traced to kd DR bandwidth, not friction training - by digging resolved params across 8 lineages, 3840 cellskd-bandwidth-mu-law-attribution
    Mechanism understoodomniattributionattributiondomain-randomizationprocess

    Attribute capability differences by tabulating every lineage's resolved training params and eliminating zero-variance and non-aligned columns first; never let an eval-side override knob serve as the explanation axis, and never write a mechanism into a law before it survives a targeted test.

    Symptom

    Lineages differed wildly in low-ground-friction survival, and the intuitive explanation - "some trained ground friction, some didn't" - was about to steer the ladder toward a ground-mu training rung.

    Context

    The attribution ran as a full parameter-vs-result cross: 8 lineages x 4 eval kd levels x 6 mu levels x 20 seeds = 3840 cells, with each lineage's RESOLVED training params dug out and compared item by item. First kill: all 8 lineages had ground mu pinned at (1.0,1.0) - zero variance - so low-mu differences cannot come from friction training at all. The only training parameter aligned with the mu score was kd DR bandwidth: narrow (<=0.24) lineages scored 19.9/19.5/19.5, wide (>=0.40) scored 17.1/15.2/14.6/14.2/12.8 - the two groups completely non-overlapping. Every rival was excluded item by item (kd center no; kp band no; COM small-beneficial non-driving; friction rung a clean double null 19.5->19.5 and 15.2->14.6; iteration count non-monotonic), and the one clean single-variable causal link confirmed it: the s2e-3 kd surgery (0.7,1.3)->(1.08,1.32) moved the score 17.1->19.5. Counter-proof against "each best at its own operating point": the narrow-band lineage evaluated OUT of band (18.2) still beat the wide-band lineage at its own band center (9.2). Two axes were ordered never to be conflated (the first attribution's own error): training kd bandwidth is a parameter axis / lineage property; the eval-side --kd-scale knob is a plant axis (more damping physically helps on slippery floors for ALL policies) - "plant 轴只能当部署缓解,不能当 归因". A tempting mechanism story ("drag vs step attractor") was tested and falsified, and explicitly kept OUT of the law: "机制未定, 不入定律".

    Change

    The planned ground-mu training rung was recommended closed ("建议 不开") in favor of a kd band-narrowing rung (0.8,1.2)->(0.9,1.1) centered on the deployed value - with a pre-registered risk that the law demands "bandwidth = measured dispersion" and the real robot's kd dispersion was not yet measured; if it exceeds +/-10%, narrowing sacrifices real coverage and the rung must yield.

    Outcome

    A whole training rung was deleted from the ladder by attribution alone (the second S2 pass dropped mu and push, 5 rungs -> 3); floor material became a deployment-selection input (mu <~0.6 -> deploy the kd1.2 gain profile) rather than a training target.

    Mechanism

    Cross-lineage performance differences must be attributed over the actual training-parameter table, not over eval knobs or plausible stories: eval knobs act on the plant for every policy (a physical effect), while lineage properties come only from training-time parameters. Zero-variance columns are free eliminations, and one clean single-variable rung is worth more than any correlation.

    Applies when

    • explaining why lineages differ on a robustness axis
    • an eval-side knob (gain scale, power) changes results and invites misattribution
    • deciding whether to open a DR rung for an axis never actually varied in training
    “8 血统地面 μ 训练带全部钉 (1.0,1.0) 零方差,低 μ 差异与「训没训地面摩擦」无关,是 kd DR 带宽的副产物 … 宽 ≤0.24 → 19.9/19.5/19.5;宽 ≥0.40 → 17.1/15.2/14.6/14.2/12.8, 两组完全不重叠。… 训练 kd 带宽 = 参数轴/血统属性;评测部署 --kd-scale = plant 轴 … plant 轴只能当部署缓解, 不能当归因。… 机制未定, 不入定律。”
    train/OMNI_V0_SPEC.md § 4. 地面 μ 鲁棒性 = kd DR 带宽的副产物 (2026-08-08)
  • Brief the operator on the lineage's measured zero-command and untrained-axis behavior before handing over the joystickknow-zero-command-behavior
    Replicatedomnireal-deployreal-acceptanceprocess

    Before any teleop/demo, measure and write down the policy's zero-command behavior and per-axis competence, label untrained axes explicitly as not-bugs, and set the floor/procedure to accommodate the known drift.

    Symptom

    A teleop session was about to start on a policy that does not stand still at zero command and has never been trained on lateral commands - behaviors an unbriefed operator would report as bugs or emergencies.

    Context

    Three measured facts were written into the teleop instructions ("都有 实测依据, 不是猜"): (1) A/D (lateral) keys will get essentially no response - probe-measured sidewalk tracking ~3%, an untrained axis: "这正是 C4 要解决的事, 不是 bug"; (2) no keypress = cmd 0, and this lineage does not stand still at zero command - a three-generation lineage property: paces in place, drifts right ~5 cm/s, net rotation -30 deg/20 s; sim survival is 20/20 (it will not fall) but it walks away slowly, so leave floor margin especially on the right; (3) S (backward) WILL respond - probe-measured 20/20 survival, 67% tracking untrained, which is also why this root was chosen for the C ladder. Plus a keybinding dry-run while suspended before touching down.

    Change

    Operator briefing became part of the deployment artifact: expected response per key, expected idle behavior with magnitudes and directions, and the distinction between untrained (expected, not a bug) and abnormal.

    Outcome

    The session proceeded with correct interpretations available in advance; the known zero-command wander was handled by floor margin and start-with-command procedure rather than misdiagnosed on the spot.

    Mechanism

    A learned policy's off-nominal behaviors (idle drift, untrained axes) are lineage properties, stable and measurable in sim beforehand; operator surprise converts known properties into false incident reports and unsafe reactions. A briefing transfers the measured behavior model to the person holding the controller.

    Applies when

    • handing a learned policy to an operator or demo audience
    • the policy idles in a non-stationary way at zero command
    • some command axes are untrained in the current lineage
    “A/D 基本不会有反应 —— s1e 从未训过非零 vy, 选根探针实测侧走跟踪率 ~3% … 这正是 C4 要解决的事, 不是 bug。… 不按键 = cmd 0, 而 s1e 在零指令下不站定 —— 血统属性, 三代实录: 原地踏步 + 右漂 ~5 cm/s + 净旋 −30°/20s。”
    train/REAL_RUN_S2.md § 附: WSAD 遥控 上机前必须知道的三条
  • Before training a one-leg stand, the accounts and a probe showed the default gains could not hold it at all - kp 20 needs 0.39 rad of error to carry the static roll moment, more than the whole adduction range - so per-joint gains came first, and thermal limits set the session lengthsingle-support-gain-authority-probe
    Mechanism understoodonelegplant-calibrationactuator-modelingplant-calibrationhardware

    Before training a posture that loads one joint statically, compute the steady tracking error load/kp and the series stiffness against m*g*h, and prove with a simple hand-written controller that the posture can be held under the deployment gains - change the gains first if it cannot; then size session length from the thermal account.

    Symptom

    The one-leg line (standing on one foot, the other folded back, no hopping) had to decide whether the existing gain profile could hold single support before any reward was designed.

    Context

    Hardware accounts (9.792 kg, COM 0.234 m high, 170 x 80 mm feet, legs 80% of the mass): moving the COM over one foot needs 107 mm of shift and the 20 deg hip-roll adduction range gives 131 mm - geometrically enough. The static frontal moment is 7.8-9 N*m, within RS02's 17 N*m - torque is enough. But at kp 20 carrying 7.8 N*m needs 0.39 rad of tracking error, more than the entire adduction range, and the real robot had already shown it: commanded +0.17, actual -0.04 (0.21 rad droop) under load, 0.0008 rad hanging - load, not the motor. A probe (probe_oneleg.py) then showed open-loop PD cannot hold single support on physics grounds, so the criterion became "an equilibrium exists and a hand-written 4-gain COM feedback can hold it": single-support roll stiffness is hip and ankle in series and must exceed m*g*h_com = 22.5 N*m/rad; ankle kp 12 in series with hip kp 80 gives only 10.4 (open loop 16/16 fell), ankle 60 with hip 80 gives 34.3 (52% margin).

    Change

    A per-joint gain profile (rl_oneleg: hip_roll kp 80, ankle_roll kp 60, the rest as rl_default) - which needed per-joint gain support in robot.yaml, the bridge, deploy and the trainer's actuator groups - decided before training. Thermal account: single support makes hip_roll the dominant heat load (about 7.8 N*m against a 7 N*m continuous rating), so acceptance and demos run in segments of at most 60 s with a temperature check.

    Outcome

    Under rl_oneleg the hand-written feedback held six cells cleanly for 6 s (hip_roll steady torque 2.1-3.4 N*m, half the thermal budget); under rl_default the same feedback on the same cells fell 0/4. The trained V0 policy then passed its 40-cell acceptance.

    Mechanism

    With PD position control, the steady error needed to carry a static load is load/kp; when that error exceeds the joint's range the posture is unreachable whatever the policy does, and series compliance between joints lowers the effective stiffness below the gravity stiffness that single support demands.

    Applies when

    • single-support, crouched or one-arm-load postures on PD actuators
    • a joint "droops" under load on hardware but tracks well when hanging
    • deciding whether a new skill needs its own gain profile
    “但 kp=20 时撑住 7.8 N·m 需要 **0.39 rad 跟踪误差 > 整个内收行程**。真机已实测: 命令 +0.17 实际 −0.04(droop 0.21 rad),悬挂时 0.0008 rad——是负载不是电机。 … 单支撑滚转是 hip/ankle **串联**刚度,必须 > m·g·h_com = 22.5 N·m/rad;ankle kp12 串 hip80 只有 10.4(开环 16/16 全摔),60 串 80 = 34.3(裕 52%) … **rl_default 同反馈同格 0/4 全摔**(增益档必要性对照)”
    git:Lucen V2@origin/oneleg-line:train/ONELEG_V0_SPEC.md § §1-1 单脚站: 几何可行,卡点是 hip_roll 增益权限 / §2 A 线增益 / §5 probe 定谳
  • Real-robot trials of a new skill were staged by risk - a hanging dry run with the robot posed by hand, then one short try per category on a mat with the hardest last, then the composed behaviour (switch + walking) last - with the user present and a log every timestaged-hang-mat-floor-for-get-up
    Replicatedrecoveryreal-deployreal-acceptanceprocess

    Stage a new skill's hardware trials by risk - hanging dry run posed by hand, one short try on a mat per start category with the hardest last, the composed behaviour last - with an operator ready to cut enable and a log for every try; relax a safety ban only for short, attended runs and say so in writing.

    Symptom

    A get-up policy acts violently near the ground by design, and the first unstaged real run of the line was stopped as dangerous.

    Context

    The hanging checklist written with the first stamped recovery product (v2_5, 2026-08-11), to be ticked item by item with the user present: both machines on the same commit and firmware torque limits checked; the robot hung from a single point about 0.1 m off the ground; a dry run with the robot posed by hand into supine and prone to watch that the target stream is gentle (the beta contract keeps targets within +/-0.25 rad of the measured pose, so enabling causes no homing fling); the first floor try is supine only, on a mat, once, with torque and joint logs; categories are added one at a time, prone last; any kicking or oscillation cuts enable immediately. For the switch (08-14) the runbook orders: hang with the standing policy as the locomotion side, then on a mat push the robot over and let it recover, and only last swap in the walking policy. An exemption was also written: edge-standing policies stay banned from long or unattended runs, but a short single A/B with the user present, hung or on a mat, is allowed. The one-leg line reused the same order (hang, then floor with a spotter, 60 s segments with a temperature check).

    Change

    Real trials as a checklist of stages, each gated on the previous one, with the composed behaviour last.

    Outcome

    The line's first real get-up (v2_6, 08-11) came through this protocol and was reported "fairly stable"; no further hardware outcomes of the switch are recorded in the spec.

    Mechanism

    Each stage exposes one new risk (commanded targets without contact, a single category with contact, harder categories, then the interaction of two policies), so a failure is attributable and cheap.

    Applies when

    • first hardware trial of a recovery, jumping or other high-impact skill
    • switching between two policies on hardware for the first time
    • a policy with a known posture defect needs a comparison run
    “吊挂空跑: 手动摆到 supine/prone 姿态, 看目标流是否温和 (β 帽 7.5 N·m, 目标永远贴着当前 q ±0.25 rad —— 使能瞬间无归位甩动, 这是 β 契约附带保证) … 落地首试: supine 一类, 垫子, 单次; τ/q --log 全程记录 … 逐类别扩展 (prone 最后), 每类先单次”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §40 吊挂执行单(真机首试;需用户在场,逐项打勾)
  • Three hardware accounts locked the run design point - and the knee's real speed ceiling is tau_limit/kd, not the firmware limitfeasibility-accounts-lock-design-point
    Mechanism understoodrunplant-calibrationplant-calibrationactuator-modelinghardwareprocess

    Before opening a dynamic-gait training line, compute the full account set - tau_limit/kd effective speed ceilings, joint ROM under the intended reference geometry, and thermal RMS at the duty cycle - and let the accounts lock the design point; move only to pre-registered in-table alternates, re-running the accounts first.

    Symptom

    The run line was believed to require a firmware raise of the RS06 speed limit (10 rad/s) as a hard precondition, and the feasibility script's motor-envelope scan had marked 80/100 mm foot-lift cells "physically feasible".

    Context

    Three added accounts re-decided everything. (1) Damping tax: in MIT mode tau = kp*(q_des-q) - kd*qd, so sustained rotation is capped at tau_limit/kd = 12/1.5 = 8 rad/s - below the firmware's 10; at peak speeds 6.7-7.9 rad/s the damping term alone eats 10.1-11.9 N*m (84-99% of the torque limit). "提固件 limit_spd 越不过这道税 —— 它是 kd 与限扭的比,不是固件旋钮." (2) Joint ROM: the feasibility script had checked motor envelopes but NOT joint range - the ankle-pitch ROM caps 1:2:1 leg-shortening lift at 62 mm (soft) / 77 mm (hard), so the 80/100 mm "feasible" cells were voided; also firmware-independent. (3) Ankle thermal: duty 0.40 puts ankle RMS at 87% of continuous rating (0.35 -> 93%); long-period big-stride cells hit both ankle torque peak and heat. Verdict: firmware raise DEQUEUED (50 mm design point needs knee 6.7-7.3 < the 8 rad/s effective ceiling < firmware 10); vel_limit stays 10 so sim == robot. The three accounts uniquely lock the design point - 50 mm lift / T 0.60 s / duty 0.40 - "三笔账 唯一锁定,不是调参空间", with pre-registered alternates allowed only inside the table and only after re-running the accounts.

    Change

    Design point frozen from accounts; hardware precondition reversed by arithmetic rather than by test; reference amplitude (0.84 rad = FK inverse of 50 mm) derived, per-joint action scales sized to the required travel (knee 0.9, hip_pitch 0.6, ankle deliberately NOT amplified - hard limit is adjacent).

    Outcome

    A firmware work item left the critical path; an infeasible region of the design space was closed before any training; the remaining risk (knee tracking lag from the damping tax) was pre-registered with its own criterion and in-table fallback (duty 0.35) - "这不是'奖励没调好', 是 plant 账".

    Mechanism

    PD actuators in MIT mode pay kd*velocity out of the same torque budget that tracks position, so the effective speed ceiling is a ratio of configuration constants, invisible to firmware settings; and feasibility is the intersection of ALL constraint families (torque envelope, joint ROM, thermal RMS) - a scan that omits one family certifies impossible cells.

    Applies when

    • planning running/jumping or any high-rate gait on PD actuators
    • a firmware or hardware upgrade is assumed as a training precondition
    • a feasibility scan covers motor limits but not ROM or heat
    “膝的有效速度顶 = τ_limit/kd = 12/1.5 = 8 rad/s,不是固件的 10。… 提固件 limit_spd 越不过这道税 —— 它是 kd 与限扭的比,不是固件旋钮。… 可行性脚本只查了电机包络没查关节 ROM —— 其 80/100mm 的"物理可行"格作废。… 判决:RS06 提固件对 run v0 不是前置,出队”
    train/RUN_V0_SPEC.md § 1. 硬件账判决 / 2. 步态设计点
  • The first real-robot get-up was "very violent, kicking on the floor, dangerous" - a sim-perfect policy with no reason to be slow, unbounded absolute targets, no domain randomization and a rate limiter that filtered nothing; the task was restated as "safe, slow, transferable"first-real-get-up-violent-stage-one-policy
    Observed oncerecoveryreal-deployreal-acceptanceactuator-modelingattribution

    Do not put a get-up policy on hardware until its action is bounded (hard bound or state-anchored targets), smoothed, randomized and tested at the real pipeline's latency, and say explicitly that the task is "safe, slow and transferable" - a simulation-perfect policy optimizes only "gets up".

    Symptom

    On 2026-08-09 the user ran a V0-lineage recovery policy on the real robot and stopped it: very violent, kicking on the floor, dangerous. The planned next rung (a heavier torque_headroom) was never started.

    Context

    The spec had pre-registered that R0/R1 products stay in simulation and that the real-robot precondition was the R3 smoothing rungs plus a bridge-slew check plus a hanging protocol; the robustness (DR) rungs had not run. In simulation the policy passed 100% with a get-up of about a second. Which ONNX, which gain profile and whether a torque/joint log existed were left "to be recorded later" and never were.

    Change

    The V0 ladder was stopped at its best product (R3.1, sim only) and a re-rooting proposal was put to the user. The spec's four-layer account: style (the reward pays for standing early and nothing pays for slowness - HumanUP's "Stage I" get-up, "fast but unsafe ... infeasible for real-world deployment"); impact (full-range absolute targets with no hard bound, raw |a| up to 4.77, action saturation 100%, a single-step change of 0.306 saturating hip_pitch); transfer (zero DR, friction pinned at 1.0, the learned leg bracing); link (the bridge's RL slew equals vel_limit, 0.2-0.66 rad per step, while the real pipeline has 1-2 steps of time-varying latency and acceptance ran at delay 0).

    Outcome

    The line was re-rooted twice (training-side rate limit, then the beta-anchored action space) and gained a hang protocol before the next real attempt; on 08-11 a beta-anchored policy produced the line's first real get-up.

    Mechanism

    A task reward that pays for standing early selects the fastest feasible get-up; with absolute full-range targets every large target jump is a torque impulse bounded only by the clip; zero DR and braced-leg solutions do not transfer; and a limiter set at the velocity limit does nothing at 50 Hz.

    Conflicts

    The four layers are the spec's reconstruction from simulation probes and the literature; the real run's policy file, gain profile and log were never recorded, so no layer was confirmed against hardware data.

    Applies when

    • a first hardware trial of a high-effort skill is being scheduled
    • sim success is high but the policy saturates actions or torques
    • pre-registered hardware preconditions are not all met
    “用户真机反馈:**非常猛、地上乱踢、危险**,叫停(R3.3 torque_headroom 加档已选型 weight −0.5→−1.5,未启动)。真机细节(哪个 onnx、什么档、有无 τ/q log)**待补记** … 任务从"能起来"变成 **"安全、慢、可迁移"** … **链路层**:桥层 slew RL 档 = vel_limit(10/20/33 rad/s ≈ 每拍 0.2~0.66 rad), 对 recovery 形同虚设;真机 1~2 拍时变延迟,验收默认 delay 0。”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §26 真机叫停与换根判决(2026-08-09)
  • The deploy-side walk/recovery switch - into recovery at tilt > 65 deg held 0.3 s, back at tilt < 15 deg with angular rate < 1 rad/s and straight knees held 1 s, a 15 s timeout, last action cleared both ways - and the handoff steps the design required are only partly implementedwalk-recovery-fsm-handoff
    Observed oncerecoveryreal-deployreal-acceptancecontract-freezeprocess

    Specify a deploy-time controller switch as hysteretic, time-filtered predicates the robot can measure (proxy what it cannot, e.g. straight knees for height), a timeout that ends in a safe stop, and a complete handoff (history, clock, last action, command ramp) - then test that the code performs every handoff step, because the design document is not the implementation.

    Symptom

    With a recovery policy and a locomotion policy as separate networks, the robot needs a switch: when is it "fallen", when is it "up", and what state must be reset so the next policy does not act on the previous one's history.

    Context

    The 08-09 design: enter recovery when fallen (tilt > 55 deg or height < 0.60 x 0.384 m) for 150 ms, leave for a stand-hold when upright (tilt < 12 deg, height > 0.85 x 0.384 m, feet steady, |omega| < 0.8) for 400 ms - wide entry, strict exit, hysteresis - then a mandatory handoff trio before walking resumes (reset the walking policy's observation history, restart its phase clock at 0, clear its previous action and latency buffer) and a command ramp instead of a jump. The 08-14 implementation in deploy_policy (--recovery-policy): each policy under its own manifest contract (walk: nominal + scale; recovery: beta-anchored), the same rl_default gains, the tilt cutoff disabled; RECOVERY at tilt > 65 deg for 0.3 s; LOCO again at tilt < 15 deg and |omega| < 1 and knees straight (< 0.35 rad) for 1 s - the robot's computer has no height estimate, and straight knees stand in for height so a V3.0-style upright kneel cannot pass as standing; RECOVERY longer than 15 s ends in a safe stop; last_action cleared on both switches; command forced to 0 during RECOVERY; power scaling applies to LOCO only.

    Change

    An open account was written down with it: the recovery end state (0.355 m stance, hip yaw -/+27 deg) is outside the walking policy's training start distribution, so the first test must use stand / zero command as LOCO, and the long-term fix is to widen the walking policy's initial states rather than bend recovery's stance to suit walking.

    Outcome

    The spec records only a successful compile (py_compile); the hang test was left to be done on site. The operator runbook carries the three-step procedure (hang with stand as LOCO, mat and push, then omni walk as LOCO) but no outcome.

    Mechanism

    Two policies trained separately each assume their own history, clock and last action; a switch that carries any of them across feeds the next policy a state it never saw - the design called this "the walking policy seeing a ghost history".

    Conflicts

    The 08-09 design requires resetting history, clock and previous action plus a command ramp; the 08-14 implementation records last_action clearing and a zero command during recovery; the one-leg spec of 2026-09-14 lists the handoff hygiene as specified but not implemented - reset_history() is called by nothing (a 215-dim policy would carry four frames of pre-fall history), the phase clock is not zeroed, and there is no command ramp back to LOCO. No hardware run of the FSM is recorded in either source.

    Applies when

    • switching between separately trained policies on hardware
    • a policy with history or phase observations is re-enabled mid-run
    • the robot lacks a sensor the switching criterion was designed around
    “**判据**:进 RECOVERY = 倾角 >65°(`--fall-tilt-deg`)持续 0.3 s;回 LOCO = §5 真机可测子集:倾角 <15° ∧ |ω|<1 ∧ **膝直 <0.35 rad(NX 无高度观测, 高度门用膝直代理 —— 防 V3.0 型"跪坐但直立"误判)** 持续 1 s (`--recover-hold`);RECOVERY 单次 >15 s(`--recovery-max-time`)安全停。 … **切换卫生**:两向切换 last_action 清零;RECOVERY 态 cmd 强制 0”
    git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §50 FSM 双策略调度(2026-08-14,用户令):deploy_policy --recovery-policy
  • Every power cycle starts with the same read-only pre-flight - read the buses, check the torque limits against 12/17/11, verify the IMU axes, check the ports after any new USB device - and any reassembly re-measures the joint zerospower-cycle-preflight
    Observed onceinfrareal-deployreal-acceptancehardwareprocess

    Start every powered session with a fixed, read-only pre-flight - bus responses, torque limits equal to the simulated ones, IMU axes, device identities - and re-measure joint zeros after any mechanical reassembly before running a policy.

    Symptom

    Hardware state drifts between sessions in ways no policy can see: a motor that stops answering after a power cycle, a torque limit that differs from the one simulated, an IMU axis flipped, two USB devices swapping identities, a joint zero moved by reassembly.

    Context

    The runbook's session order before any policy runs: read every motor on both CAN buses without enabling them (the first command after every power cycle); set_torque --check, all twelve motors must read 12/17/11 N*m, and any difference is written back; imu_reader --verify-axes, where the operator tilts the robot forward and to the right and every check must pass before continuing; check_ports after plugging in any new USB device (the IMU and a CAN adapter once collided on USB identity). After re-mounting motors: read the buses, then re-measure the calibration offsets (three repeats, written back) - "skipping it means running everything on the wrong zero". Hanging checklists repeat the torque-limit check (the deploy script also self-checks at start).

    Change

    A fixed, read-only pre-flight run in the same order every session.

    Outcome

    The runbook records one earlier hardware check in the same spirit: all 12 motors' implied kp fell within 18.4-22.0 for a commanded 20, inside the kp randomization range used in training.

    Mechanism

    A policy transfers only if the plant matches the one it was evaluated on; the pre-flight turns silent hardware drift into a failed check before the robot moves.

    Applies when

    • the first command after powering a robot on
    • after swapping adapters, cables or motors
    • a policy that worked last session suddenly behaves differently
    “python tools/set_torque.py --check # 12 颗应全对 12/17/11, 有 diff 就 --write … 插任何新 USB 设备后都先跑一次 check_ports.py(IMU 和 CANable 的 USB 身份撞过车) … python tools/calib_stance.py --repeat 3 --write # 重标 offset —— 8/9/10 重新装, 机械零位变了”
    RL系统/FOLLOW THIS copy 2.md § WALK / STAND 每次开始前 / 换CAN / 装回后必做两件
  • Teleop fed the sidewalk axis a command beyond its training band - feet clipped; give each axis its own speed settingteleop-command-band-per-axis
    Mechanism understoodomnireal-deployreal-acceptancehardwareattribution

    Give every command axis its own teleop scale, clamped to that axis's training band, and reproduce any hardware incident in sim with the exact deployed command values before touching training.

    Symptom

    Robot stepped on its own foot when sidewalking left under teleop - and only when going left.

    Context

    The teleop tool used one speed setting for all axes: --teleop-speed 0.20 applied to A/D sent cmd_vy = 0.20, above the training band's top (0.08-0.18) where foot-spacing margin is thinnest. Sim reproduction of the incident (product policy, pw0.8, 5 seeds x 20 s, true collision threshold = single foot width 104 mm): at vy 0.20 the minimum foot distance was 111-115 mm - 7-11 mm from self-collision - vs 147 mm at vy 0.10. Left was 4x more dangerous than right (25% vs 6% of time inside the 160 mm soft wall at vy 0.10), matching the left-only symptom; the margin did not degrade over time (pressing more just lengthened exposure).

    Change

    deploy_policy gained --teleop-side (default 0.10), separating the lateral speed from the forward speed so each axis's teleop command sits inside its own trained band.

    Outcome

    Command now inside the band with 43 mm margin at default; the incident became a quantified, reproduced, closed account rather than a mystery.

    Mechanism

    The policy's competence envelope is the training command distribution per axis; teleop mappings that share one scalar across axes silently command out-of-band inputs on the weakest axis. Asymmetric risk (left vs right) came from the policy's own chirality bias, so a symmetric command produced an asymmetric hazard.

    Applies when

    • wiring a joystick/teleop layer over a learned policy
    • a hardware incident occurs on one command direction only
    • training bands differ across command axes
    “A/D 一直与 W/S 共用速度档,所以按 A 下发的是 vy = 0.20 —— 既超训练带(0.08~0.18)上沿 … 0.20(遥控实际值)| 111~115 mm | 7~11 mm … 且左比右危险 4 倍 … 处置:deploy_policy 新增 --teleop-side(默认 0.10),侧移与前进档分开。”
    train/C_LADDER_RUN.md § 3p. 一 向左走踩到自己 → --teleop-speed 0.20 同时喂给了 vy
  • Run acceptance under measured contact parameters - honest condim/torsional-friction flipped a false PASS into a real-matching FAILeval-plant-honesty-contact-params
    Mechanism understoodwalksim2sim-gatesim2simplant-calibrationgate-battery

    Pin the evaluation plant's contact model to measured values (contact dimension, torsional/rolling friction, mu) before trusting any gate that involves slip, impact, or drift - a gate can only fail a policy for physics its simulator contains.

    Symptom

    walk_v5 passed the old acceptance battery yet failed on the real robot (footfall force, drift, kicking) - the evaluation plant was flattering the policy.

    Context

    The battery was re-run under "honest contact parameters" - condim 4 (adding torsional contact) with measured torsional friction 0.035 - and v5 then FAILED exactly the rows corresponding to its real problems: heading 185 deg (limit 30), support-foot yaw slip 284 deg (limit 80), landing force 1.72x (limit 1.5x), suspended tilt 45.9 deg (limit 10). The slip physics depends on torsional friction, which the default contact model (condim 3) does not even simulate - a slip problem is invisible to an evaluator that cannot represent yaw friction at the foot. Term-sizing measurements for the new rewards were likewise taken under the same honest parameters (cmd 0.45, skipping the 5 s start transient).

    Change

    Acceptance harness pinned to condim 4 / torsion 0.035 (measured); verdicts issued under defaults declared non-citable for these rows.

    Outcome

    Sim acceptance verdicts began agreeing with hardware ("现在失败, 与真机一致"); the v6 fixes could be developed and validated against an evaluator that could actually see the disease.

    Mechanism

    An evaluator is a plant model too: contact dimensionality and friction values decide which failure modes exist in the simulation at all. Evaluating under default contact parameters tests the policy in a world where its real failure is physically impossible, producing structurally false PASSes.

    Applies when

    • sim acceptance passes policies that fail on hardware
    • slip/drift/impact gates run under default simulator contact settings
    • setting up a cross-simulator evaluation harness
    “accept_v2.py 已加三条判据, walk_v5 在诚实的接触参数下(--condim 4 --torsion 0.035)现在失败, 与真机一致:直行 15s 航向累计 <30° | 185° ✗ … 落脚力峰值 <1.5× 体重 | 1.72× ✗”
    train/WALK_V6_MINIMAL.md § 5. 验收
  • Training at scale 0.4 is NOT the twin of deploying 0.5 at power 0.8 - the algebra matches, the learned policy does notdeploy-scaling-not-training-equivalent
    Mechanism understoodomniattributionattributioncontract-freezesim2simcurriculum

    Never assume deploy-side scalings can be folded into training-time constants ("burning the crutch into training"): the learned optimum depends on the training-time authority, so treat such conversions as full experiments with pre-registered expectations and a sim2sim gate before any hardware.

    Symptom

    s1g (S1.6) trained from zero at action_scale 0.4 - meant as the "training twin" of the hardware-proven s1c-at-power-0.8 (0.8 x 0.5 = 0.4) - was all green in Isaac (zero falls, reward 117) yet scored 0/3 across all eight checkpoints and 0/20 at 20 seeds in the MuJoCo gate, falling forward at median 1.57 s with a 2.9x speed overshoot.

    Context

    The pre-registered expectation (survival gate should pass, since the conviction matrix showed s1c@0.8+delay2 all-survive) was cleanly falsified, and the harness was acquitted by controls: --delay 0 fell identically (not a delay fragility), check_contract all green, and s1c through the same harness survived 2/3. The verdict: "「s1c@0.8 = 0.4 训练孪生」的代数等价不成立" - a policy deployed with a derated output still LIVES in the 0.5 internal model it trained under (its value function, its expectations of its own authority), while a policy that starts training with reduced authority learns a different, clip-hugging gait with zero margin for plant differences ("部署端打折的策略活在 0.5 的内模里,训练起点收权限学出的是贴 clip 的 另一套步态,对 plant 差异零余量"). Result: the policy was withdrawn before hardware ("撤回——不上真机"), the lineage root moved back to the 0.5-contract s1c-5500, and this became the C ladder's cited fact-check ("s1g 是 0/20 证伪出局的那一代").

    Change

    The amplitude-surgery route abandoned; contract kept at scale 0.5; the deploy-side 0.8 crutch later retired on its own merits when the delay-complete s1e generation ran at full power.

    Outcome

    One training run bought a clean falsification of a plausible algebraic identity; no hardware time was spent on it because the sim2sim gate caught it.

    Mechanism

    Output scaling commutes with the network arithmetic but not with learning: the training-time scale shapes which gait solutions are reachable and how much clip headroom the optimum keeps. A derated mature policy retains the wide-authority solution executed softly; a from-zero narrow-authority policy finds a different optimum that saturates its smaller envelope - the two are not the same controller in different units.

    Applies when

    • proposing to move a deployment derating into a training constant
    • a scaled-down contract policy hugs the action clip
    • Isaac-green / cross-sim-zero results on a re-scaled lineage
    “预注册 a) 证伪——Isaac 全绿(零摔/reward 117)但 MuJoCo --delay 2 八档 checkpoint 扫描全数 0/3、iter6500 20-seed 0/20 … 「s1c@0.8 = 0.4 训练孪生」的代数等价不成立: 部署端打折的策略活在 0.5 的内模里,训练起点收权限学出的是贴 clip 的另一套步态,对 plant 差异零余量。”
    train/OMNI_V0_SPEC.md § 3. S1.6 判决(2026-08-07 验收)
  • Knee swing collapsed because it directly trades against the slip penalty - price the conflict explicitly and clamp what reward cannot holdknee-swing-vs-slip-pricing
    Mechanism understoodwalkreward-shapingreward-shapingattribution

    When a behavior collapses as another metric improves, look for the term pair trading them and set their price ratio deliberately (with escalation and reverse tripwires pre-registered); where the policy actively spends action budget to undo your target, stop paying more reward and clamp the target space structurally.

    Symptom

    Knee peak-to-peak swing collapsed across generations - v5 33 deg, v10 26-30, v10b 7-8, v11 6.5-8.6 - and rolling the clock back did not recover it, acquitting the clock; the collapse tracked the gated slip penalty instead: "屈膝与不打滑在当前奖励里直接对抗" - v10b's excellent 93 deg slip was purchased with knee amplitude.

    Context

    Reward-side flexion fixes had failed three times: raising reference amplitude backfired twice (v9/v11), and v11's deep-squat default was actively fought by the policy - it spent 0.68 of action budget pulling the squat straight ("被策略花 0.68 动作拉直反杀"). v12's design accepted the conflict as real and attacked on two tracks: (1) ECONOMICS - a direct knee_swing_amplitude reward (+0.3, target 0.55 rad, capped at 0.6/step = 55% of tracking), explicitly opposed to the slip penalty by design ("显式对立——这正是设计:v12 就是这场对抗的定价实验"), with an escalation ladder (K +0.3 -> +0.5, then slip -0.5 -> -0.3, one layer at a time) and a reverse tripwire (slip telemetry back at v10 levels -> slip weight to -0.8, accept ~20 deg knee compromise); (2) STRUCTURE - knee target bounds [0.2, 0.9] rad so full straightening is physically impossible (straightest 11.5 deg) and the 0.68 fighting budget is released. A bonus falsifiable prediction was attached: phase-lock strength tracks amplitude (v9_probe 48 deg locked 2.5 Hz; v11 low-amplitude 1.36 Hz unlocked), so if K works, hardware phase-lock should return - one change, two verdicts.

    Change

    knee_swing_amplitude reward + knee target clamp + pre-registered escalation/reverse levers; the failed reward-side-only approach retired.

    Outcome

    The lineage was frozen before v12 trained (strategic reset), but the diagnosis stands as the walk line's clearest example of two reward terms trading a behavior between them, with the pricing experiment and structural clamp fully designed and calibrated.

    Mechanism

    When two terms price opposite aspects of one motion (swing amplitude creates yaw momentum that becomes slip), the optimizer settles wherever the price ratio puts it - patching one side moves the equilibrium, not the conflict. Explicit pricing makes the trade a designed quantity; structural clamps remove the regions where the policy spends budget fighting the designer.

    Conflicts

    The pricing experiment (K vs slip) was designed and calibrated but never trained - the 2026-08-05 reset suspended v12; the collapse attribution table and the 0.68-action counterattack are measured, the remedy's效果 is untested.

    Applies when

    • one gait quality degrades in lockstep with another's improvement
    • the policy visibly fights a default pose or reference
    • repeated reward-side fixes for the same behavior have failed
    “膝摆塌在 v10→v10b,头号嫌疑是门控滑移罚(四代实测膝 p2p:v5 33° / v10 26~30° / v10b 7~8° / v11 6.5~8.6°;退时钟没救回 → 非时钟)——"屈膝"与"不打滑"在当前奖励里直接对抗 … 奖励侧修屈膝已三败 … v11 深蹲 default 被策略花 0.68 动作拉直反杀”
    train/WALK_V12_SPEC.md § 0. 定位 / 2. K —— 膝摆经济(与滑移罚的对偶)

Next page