Training Coach
Doctrine
A report may cite any of these as doctrine-N.
doctrine-1Contract freeze and fingerprint disciplineThe policy I/O contract (observation layout, scales, history semantics, action pipeline) is frozen and fingerprinted; every exported policy is stamped and verified; contract changes ship as new versioned profiles that leave old artifacts bit-identical, and old policies run forever under their era's pinned profile.
Case. The 215-dim omni contract was frozen with a three-machine digest; the one contract-level extension (lateral feed-forward) went in as a new `omni_ff` profile with the old profile provably untouched, and the contract checker caught two real wiring bugs before any training (`contract-freeze-and-checker`). A silently changed gait-clock default would have fed old policies a 25% slower clock - closed by pinned legacy profiles (`legacy-profile-pinning`). A stale derived USD forked plant mass 2.2% until an automated source-vs-derived instrument gated it (`derived-asset-staleness-check`). A gain profile is part of the closed loop a policy was trained in and belongs in its stamp; the recovery line's anchored authority was left out of its manifest and recorded as the gap not to repeat (`gain-profile-belongs-in-the-stamp`), and a second policy behind a deploy-side switch made the handoff state itself a contract (`recovery-two-policies-and-a-state-machine`, `walk-recovery-fsm-handoff`).
Coach application. On any proposal touching obs/action semantics, defaults, or derived assets: demand the version/profile plan, the fingerprint update, and the checker extension in the same change; flag any old artifact that would run under new defaults.
doctrine-2Attribution by resolved training params - never eval-override knobsCapability differences between lineages are explained only by digging each lineage's *resolved* training configuration and eliminating columns; evaluation-side override knobs (kd-scale, power-scale, cycle-time) act on the plant for *every* policy and may serve as deployment mitigations but never as explanations.
Case. Low-friction robustness across 8 lineages x 3840 cells was traced to kd DR *bandwidth* - every lineage had ground friction pinned to (1.0,1.0), so "trained friction" could not be the axis; the parameter axis and the plant axis were explicitly separated after the first attribution conflated them (`kd-bandwidth-mu-law-attribution`). "Weak turning" on hardware was a power-scale plant effect, not a training gap (`deploy-knob-attribution-before-retraining`); slowing the deploy clock was out-of-distribution, not a feature (`cycle-time-override-is-ood`). The ground truth for what a run trained under is the logged per-run config, not the source tree (`resolved-config-is-source-of-truth`).
Coach application. Whenever asked "why is lineage A better", require the resolved-param table first; kill zero-variance columns; refuse explanations phrased in eval-knob terms; when a knob helps, label it deployment mitigation.
doctrine-3PASS gates become constraints; FAIL gates become objectivesOnce a skill passes its gate, that gate converts into a standing regression constraint (budget <= 2/20 against the parent baseline) for all later training; gates currently failing are the only legitimate objectives of the next rung.
Case. The C ladder ran one frozen 13-cell x 20-seed matrix at every rung with promotion = "new skill PASS and old skills within regression budget"; C1 was stopped and re-rooted precisely because it trained away the root's backward PASS (`fixed-acceptance-matrix-per-rung`, `preregistered-stop-criteria-per-rung`). The C4 product shipped only at 260/260 cells with zero regression.
Coach application. Keep the ledger: every PASS adds a constraint row; propose rungs only against FAIL rows; treat any constraint violation as stop-and-attribute, never "the next rung might win it back".
doctrine-4One variable per ladder rung - counted against what the checkpoint sawA rung changes one variable, where "one" is counted against the checkpoint's actual training state, not against the current config's diff; batching is allowed only when each change owns a disjoint symptom space with a pre-registered ablation order.
Case. Two rungs failed identically because resuming s1e-500 under the evolved config silently added four plant variables the checkpoint had never seen ("单变量纪律不只看「我改了什么」,还要看「checkpoint 见过什么」" - `resume-state-dr-audit`). v8 legally batched four orthogonal fixes with a written ablation order (`orthogonal-batch-with-ablation-order`); v9 spent one run completing a 2x2 factorial so either outcome convicted a factor (`fill-the-missing-factorial-cell`); v10b's three-way ablation wrongfully convicted the clock and had to be retried fairly.
Coach application. Before any resume: diff cfg against the checkpoint's logged training state. Before any batch: require the symptom-ownership map and ablation order in writing.
doctrine-5Pre-register risks, readings, and stop criteria before the ladderBefore a ladder or risky rung, write down the known risks, the interpretation of every plausible outcome, and hit-any-one stop criteria - frozen before training, tightened when priors say results should come fast.
Case. The C ladder opened with three numbered risks including the exact falsification condition for its own root choice; A/B arms carried "预注册读法(事后不改)" tables; a level expected to fail was run anyway for its pre-registered diagnostic value (`preregister-risks-and-fork-readings`). Stop criteria caught C4-redo rungs at +200 instead of full caps (`preregistered-stop-criteria-per-rung`); hardware sessions pre-registered per-config expected signatures and the disagreement rule "不改结论改账" (`preregistered-real-expectations`, `feasibility-accounts-lock-design-point`).
Coach application. Refuse to open a rung without the written risk/reading/ stop block; after results, read conclusions off the pre-registered table and flag any post-hoc reinterpretation.
doctrine-6Plant parameters are measured, never inventedEvery plant number carries measurement provenance: armature = N^2 x rotor inertia from no-load tests, friction split by rig and by API column, torque limits shaped by per-joint gait peaks, latency traced through the real pipeline, masses weighed - and DR bands are additive around the measured nominal, sized to the measured dispersion.
Case. Guessed friction was 2.5x low and guessed damping 5x high (`friction-measured-not-guessed`); armature had been 0 with a 9:1 gearbox (81x reflected inertia, `armature-n2-rotor-inertia`); a uniform torque derating was "the wrong shape" vs measured peaks (`torque-limit-shape-by-measured-peaks`); the delay implementation itself was a wrong plant for a whole lineage (`latency-lerp-reverse-extrapolation`); the run design point was locked by three accounts including the tau_limit/kd speed ceiling (`feasibility-accounts-lock-design-point`); identified friction had to land in the right simulator API columns to act at all (`sim-api-friction-columns`). The recovery and one-leg lines opened with the same kind of accounts before any reward existed - a connected static path and the torque along it for an armless get-up, and the gains single support needs to be holdable at all (`get-up-feasibility-accounts-before-training`, `single-support-gain-authority-probe`).
Coach application. For any plant value in a config review, ask "measured how?"; reject absolute ranges with no nominal; check API column mapping and derived-asset regeneration whenever measured values land.
doctrine-7Sim2sim gate before sim2real - under deployment conditionsEvery checkpoint passes a second, independently built simulator before hardware, and both the gate and the smoke loop run under the measured deployment conditions (real pipeline delay, honest contact parameters, the deployment gain/power profile).
Case. The standing order "先sim2sim 再sim2real" (`sim2sim-gate-before-sim2real`); acceptance flipped to match hardware only under measured condim/torsional friction (`eval-plant-honesty-contact-params`); gates moved permanently to `--delay 2` after the kicking incident (`pipeline-latency-is-plant-not-dr`); and the harness itself must be audited - a frame-convention bug in the cross-sim evaluator invalidated a whole line of verdicts (`body-frame-velocity-api-audit`). The recovery line's second simulator caught a torque penalty paid for by bracing the legs together (`torque-penalty-bought-by-leg-bracing`), and a 1.8x torque disagreement between the two plants stayed binding because its one surviving explanation was never tested (`torque-disagreement-between-simulators-unresolved`).
Coach application. Block any hardware request lacking a second-sim PASS at deployment conditions; when sim2sim and training-side metrics disagree, treat the evaluator as a suspect too.
doctrine-8Observation honesty - the actor's inputs are a hardware contractThe actor observes only signals the real robot produces with realistic noise; privileged truths go to the critic; history windows are estimators and must train under plant variation; rewards on quantities the actor cannot observe buy only average suppression, never closed-loop correction.
Case. Ground-truth velocity/forces went critic-only (`observation-honesty-critic-only`); frame_hist under zero DR memorized the trainer's plant fingerprint - 0/20 transfer (`history-obs-needs-plant-variation`); world-frame yaw rewards could not teach pull-back because heading is unobservable to the actor - correction was routed to the deploy outer loop instead of breaking the contract (`reward-observability-limit`, `deploy-heading-loop-and-align-training`).
Coach application. Audit every actor-obs element for hardware existence; require minimal plant jitter whenever history/recurrence exists; for each reward, ask "can the actor see this error?" and route correction tasks to outer loops.
doctrine-9Reward economics are audited in realized currencyReward design decisions are made on realized per-step magnitudes under the actual policy and command distribution: price the do-nothing optimum before adding a mode, compare achieved values to the computed ignore-floor, calibrate thresholds between measured healthy and sick distributions, and ship every new penalty with a withdrawal clause.
Case. feet_air_time at weight 2.0 realized 0.038 vs tracking 1.2 - drag was rational (`realized-contribution-audit`); ignoring a vy command cost 28-180x less than ignoring vx until a gated tracking term was added (`reward-cost-of-ignoring-audit`, `gate-new-reward-terms-by-command`); achieved-vs-floor separated "never learned" from "priced out" (`ignore-floor-diagnosis`); the foot-distance wall was placed between measured healthy (0.6% tax) and sick (55%) policies (`calibrate-threshold-between-healthy-and-sick`); the landing penalty carried a pre-registered stand-down condition and actually stood down (`calibration-threshold-with-withdrawal-clause`); two clearance terms were inert until zero-points and gate occupancy were checked (`inert-reward-term-audit`). A get-up policy sat because three gated terms paid the seated pose 84% of the return and the one term that could tell sitting from standing was an exp kernel reading 4.6e-5 at the real error (`seated-basin-dead-exp-kernel`); a torque-tail term was weighted by its measured steady value beside a peer term after the estimate proved 12x off (`tail-torque-needs-hinge-on-computed-demand`).
Coach application. Never discuss weights in the abstract: demand the realized-contribution table, the ignore-floor number, and the healthy-pay calibration before any reward edit is approved.
doctrine-10The zero-cost option must be the desired behaviorFor every penalty, name what the zero-cost option is; penalize failure events (slip, saturation excess, contact in flight windows), never the motion or joints that healthy behavior uses; make degenerate strategies fatal via termination where penalties cannot price them out.
Case. Joint-usage penalties for drift taxed a 1.4%-of-momentum channel 2.7/step and collapsed training; the slip penalty costs a non-slipping gait exactly zero (`penalize-the-slip-not-the-joint`). A frozen-at-clamp joint pays zero action-rate forever - only a pre-clip saturation penalty flips the cheat economics (`saturation-cheating-zero-rate-cost`). Ungated phase shaping made standing 42x more expensive than stepping and cooked the hip motors (`moving-gate-42x-stand-tax`); crouch-shuffling lived until a height termination deleted it (`termination-closes-degenerate-basin`). A gated penalty is an exit: the policy parked just outside an uprightness gate, then just under a height gate, to stop paying a stance tax, and only a positive band plus an always-on guard closed both (`penalty-gate-is-an-escape-hatch`); a soft-limit penalty that charged the standing pose itself bought a 4.1 deg lean (`soft-limit-penalty-charges-nominal-pose`); an unpriced foot attitude was spent on edge-standing (`unpriced-foot-attitude-is-a-free-variable`); and the one-leg line listed its cheapest cheats before training and still met one through a zero-gradient band (`enumerate-cheapest-cheats-before-training`, `binary-band-reward-fake-touchdown`).
Coach application. Run the "零代价的选项是什么" audit on every proposed term; convert motion taxes into event-conditional penalties; check the termination set against each known degenerate strategy.
doctrine-11Measurement discipline: independent referees, signs, distributionsA disputed measurement is adjudicated only by an independent algorithm from raw state; directional ability requires sign-antisymmetry under command reversal; bimodal metrics are reported as mode shares (never medians, never 3 seeds); ratios are not comparable when totals change; reward values compare only within one command distribution; single chaotic events never cross machines.
Case. The triple reversal - a good metric was "refuted" by a sibling metric that shared the disease (`independent-referee-for-metric-disputes`, `body-frame-velocity-api-audit`); same-signed +/- responses were bias, not turning (`same-sign-response-is-yaw-bias`); the swing median sat in a bimodal gap (`median-hides-bimodal-distribution`); "v6 is jitterier" died on absolute energies (`ratio-metrics-need-absolute-check`); yaw gain measured 15x wrong in an oscillating frame (`heading-integral-not-body-rate`); a 44% improvement evaporated under same-distribution comparison (`same-distribution-reward-comparison`); drift direction was a limit cycle (`multiseed-sign-test-for-drift`); a cross-machine push cliff was chaos (`single-impulse-recovery-is-chaotic`).
Coach application. Before accepting any surprising number: ask for the independent recomputation, the sign pair, the distribution shape, and the comparison conditions. Retract in writing when a metric falls.
doctrine-12The deployment pipeline is plantIrreducible pipeline properties - action latency, rate limits, power/torque scaling, teleop command mappings - are part of the nominal plant, modeled from day one and reproduced in every gate; deploy-side scalings are crutches that flag unmodeled plant, and they cannot be algebraically folded into training constants.
Case. Right-leg kicking was over-trained-delay x loop gain; power 0.8 was a gain-reduction crutch that retired when the delay was modeled (`pipeline-latency-is-plant-not-dr`); power derating damages non-forward axes first (`power-scale-hurts-nonforward-axes`); training at 0.4 scale as the "twin" of deploying 0.5 x 0.8 collapsed 0/20 (`deploy-scaling-not-training-equivalent`); one shared teleop speed sent an out-of-band lateral command and the robot clipped its own foot (`teleop-command-band-per-axis`); the latency DR range had not even covered the measured pipeline (`latency-dr-covers-measured-pipeline`). A rate limiter added at deployment only clipped a policy that kept commanding (`deploy-rate-limiter-windup`); moved into training and anchored on the last command it became an integrator in the balance loop (`slew-anchor-is-an-integrator`); anchored on the measured angle it bounded torque and kept the bandwidth (`beta-anchored-action-target`). The walking lines' safe setting, power-scale 0.8, cut the ends of the recovery policy's full-range travel and left its spikes alone; a gain inside the trained band did the job (`power-derating-cuts-full-range-contract`).
Coach application. Demand the measured pipeline latency/limits in the plant model and in gate conditions; treat every deploy-side derating as a question ("what is this compensating?"); block per-axis command sources that exceed training bands.
doctrine-13DR budget is finite; its distribution is the measured supportRobustness is a conserved budget: disturbance training on an already-hardened lineage borrows from existing margins; DR ranges span the measured deployment support - no fictitious tails (they buy degenerate gaits), no single constants (they allow thin-margin specialization); harden the plant only after the task distribution is final.
Case. The same push dose helped a narrow lineage and damaged a balanced one - budget conservation (`push-dr-conditional-budget-conservation`); wide latency tails bought drag-glide, constant values shipped 60% thinner tilt margins - the answer is a narrow band on the measured support (`dr-tail-plant-continuation`, `constant-value-dr-overfits-margin`); task-first ordering because hardening a soon-to-change task wastes budget (`task-shaping-before-plant-hardening`); COM randomization used deliberately as a behavior-shaping tool, and rolled back on symptom per its own contract (`com-randomization-forces-leg-spread`, `com-dr-rollback-on-symptom`). DR that is switched on can still be thin: the run policy fell in the frontal plane its gain-and-latency randomization never touched (`thin-dr-judged-by-channel-coverage`), and a friction priority settled under one action contract had to be re-measured under the next (`friction-priority-re-measured-after-plant-change`).
Coach application. Before any DR rung: check the untrained policy against the spec, the lineage's current DR load, and the measured real-world range; after it: audit retained margins, not just the new tolerance.
doctrine-14Gates measure what hardware feels: posture, margins, stripped assistsAcceptance batteries carry posture-class rows (tilt max median, per-joint L/R asymmetry, temperature) beside task rows, graded margin columns beside binary gates, chirality scored per side, at least one condition that removes the environment's free stabilization, and validated predictive scalars promoted into the gate.
Case. Three same-shaped judging errors - survival, displacement, wz-difference - all missed what the operator felt; posture metrics had the predictive power (`task-metrics-vs-posture-metrics`, `stand-gate-posture-not-survival`); binary survival saturated and hid a 60% margin gap (`constant-value-dr-overfits-margin`); v5 passed everything on the ground and failed suspended (`suspension-probe-removes-free-stabilizer`); the hip_roll (l+r) scalar predicted real drift direction and ordering and entered the battery (`hip-roll-sum-predicts-lateral-drift`); averages hide chirality (`chirality-scored-separately`); gait-quality gates are judged at speeds that demand a gait (`low-speed-commands-reward-dragging`). The recovery line added the rest of the kit: where failed episodes end, not only where they started (`end-state-confusion-matrix`); a frozen acceptance distribution with a pinned seed (`frozen-acceptance-distribution-and-pinned-seed`); video of the metric rollout itself (`video-as-acceptance-record`); and the admission that a 10 s episode cannot see a stance that fails after a minute (`episode-length-bounds-what-a-gate-sees`). The one-leg line removed a foot-spacing wall that no gate measured, and the feet met on hardware (`removed-wall-returns-on-hardware`).
Coach application. Review every battery for posture rows, margin columns, per-side scoring, and an assist-stripped condition; when operator feel and gates disagree, suspect the metric class first.
doctrine-15Fork and root selection: recoverability, maturity, frozen rewardsChoose fork roots by which candidate's deficits the coming training can pay back (precision is recoverable; lost plasticity, symmetry, and margins are not); prefer mature checkpoints as roots even when younger ones score better as products; never fine-tune through a reward change - continuation is legal only with the reward frozen and plant/DR widening one rung at a time.
Case. s1e-500 beat higher-precision candidates because its exclusive strengths were unrecoverable (`fork-root-recoverable-shortfall`); the b300 arm proved maturity is capital against adaptation shock (`root-maturity-vs-product-quality`); the B-arm scatter/half-recover/collapse signature falsified reward-change fine-tuning and drew the legal boundary for S2 continuation (`fine-tune-reward-change-falsified`).
Coach application. For root debates, build the exclusive-strengths table and ask "which side can be trained back?"; require dual-arm evidence for maturity claims; classify any proposed continuation as reward-frozen or not before approving.
doctrine-16Curricula: verified engagement, lineage counters, disease-phase gatingAutomatic curricula must prove they engage (a saturated ratchet is constant DR wearing a curriculum's name); every ramp counts lineage-cumulative progress, not per-process steps; penalties aimed at late-stage pathologies ramp in after exploration noise decays; difficulty rises on measured per-stratum success, never on schedule.
Case. The s1f ratchet capped at iter 248 and never engaged (`auto-curriculum-engagement-check`); the saturation ramp re-fired at +600 after every resume and no shipped product ever saw the penalty (`curriculum-counter-lineage-steps`); the same penalty worked once gated to the disease phase and became an untouchable mechanism (`gate-penalties-to-the-disease-phase`); record-high aggregate reward hid a fully-failing delay stratum (`aggregate-metrics-mask-subgroup-failure`); bucket share is not a gradient lever (`bucket-share-is-not-a-gradient-lever`). An assist curriculum keyed to a pooled success share was withdrawn on the strength of the categories that already worked (`curriculum-criterion-conditioned-on-lagging-category`); a pace set by per-step income moved only when that income was time-gated (`per-step-income-drives-speed-time-gate`), and the same gate had to be retired in a lineage without the disease (`time-gate-vs-wide-stance-retire-the-fix`).
Coach application. Ask every curriculum three questions: does it engage (show the internal state)? what does it count (process or lineage)? when is it present (against the pathology's phase)? Check where shipped checkpoints sit relative to every ramp.
doctrine-17Probe before training: feasibility first, hypotheses in tablesAfter two failed training attempts at a skill, stop training: demonstrate the behavior open-loop, enumerate hypotheses in a written table audited against actual configs cheapest-first, race one probe per side of the sim2real boundary for hardware-only pathologies, and use suspended tests to acquit or convict actuators before blaming authority.
Case. "在黑暗里试钥匙" - four sidewalk rungs failed until an open-loop probe separated exploration/waveform/authority in one experiment (`open-loop-probe-before-reward-tuning`); the foot-drag mystery fell to a seven-hypothesis config audit (`hypothesis-table-code-audit`); the period-doubling was resolved by racing a reward-side and a plant-side evidence line - and both paid off, one per sub-case (`period-doubling-evidence-race`); the suspended test acquitted the roll actuator in one measurement (`suspended-test-isolates-actuator-authority`). A read-only configuration probe told a wall from a slope in the recovery line's seated basin (`configuration-probe-wall-not-slope`), and the fix it pointed to - where the feet are - took prone from 0/159 to 158/159 (`prone-dead-end-is-foot-placement`); a knob that did not move its variable was recorded as no test of the idea (`dof-vel-penalty-is-not-a-pacing-knob`).
Coach application. When a skill resists training, prescribe the probe before any further reward edits; require verified target trajectories before imitation terms; keep a falsified-fixes list so closed roads stay closed (`amplitude-cut-falsified-yaw-fix`).
doctrine-18External advice is recomputed locally; values transfer as ratiosEvery external suggestion is classified adopt / already-have / modify / trap by recomputing its claim on the local reward table and probe data; numeric values transfer only as dimensionless ratios (to tracking weight, leg length, sqrt(gL), control rate); citations are verified to exist.
Case. "Start vy very small" would have destroyed sidewalk learning on this reward table - the gradient scales quadratically (`external-advice-audit-against-own-arithmetic`); swing-height targets and weights transferred correctly only through leg-length and tracking-ratio scaling (`transfer-ratios-not-absolutes`); the "6-step delay" was refused for lacking a control rate (`latency-dr-covers-measured-pipeline`); a borrowed reference's structure was FK-verified and its amplitude re-derived from the division of labor (`reference-structure-fk-amplitude-division`); retrieval agents fabricated verbatim arXiv quotes - only source-verifiable material was used; and one dismissed suggestion later proved right for a different mechanism, and was credited (`cycle-average-tracking-for-gait-quantities`). An advisor's staged state machine turned out to exist in none of the three papers it cited, and reading them changed the plan (`advisor-paraphrase-vs-paper`).
Coach application. Intercept every "paper X does Y" with the local recomputation; convert absolutes to ratios before comparison; verify quotes; revisit dismissed advice when new mechanisms appear.
doctrine-19Hardware sessions are scripted experiments, not tuning sessionsReal-robot time executes a pre-registered matrix: risk-ordered (baseline first, fragile last with a spotter), stage-gated (suspended smoke before ground), A/B sessions bracketed by a repeated reference run, operators briefed on measured zero-command and untrained-axis behavior, chirality-aware disturbance protocols, no field tuning - the only legal field changes are scripted, single-variable, and self-reversing.
Case. The S2 acceptance sheet (`risk-ordered-real-deployment`, `battery-bracketed-real-ab`, `know-zero-command-behavior`, `push-test-chirality-protocol`, `no-field-tuning-protocol`); the RAM-only torque experiment with automatic power-cycle rollback (`reversible-single-variable-field-experiments`); and the sim-veto rule - even sim's condemnations get one safeguarded hardware check when they judge the purpose-built configuration (`sim-veto-needs-real-confirmation`). The recovery line's first real run went ahead with its preconditions unmet and was stopped as dangerous (`first-real-get-up-violent-stage-one-policy`); after it: a staged hang, mat and floor protocol (`staged-hang-mat-floor-for-get-up`), a fixed power-cycle pre-flight and two-machine discipline (`power-cycle-preflight`, `two-machine-config-discipline`), a fall guard replaced rather than switched off (`fall-guard-becomes-a-state`), and logs that are part of the run (`hardware-log-is-the-attribution-input`).
Coach application. Turn every hardware request into a runbook with order, gates, brackets, briefing, and anomaly plays; refuse improvised parameter changes on the floor.
doctrine-20Close questions in writing; restart when the debt is structuralAudited questions get frozen verdicts with citable wording and an explicit reopening bar; hardware verdicts are dated by deployment-stack and calibration state and expire when those change; and when successive rungs shuffle symptoms without net progress, freeze the lineage as regression baselines, pay the structural debts, and retrain minimal - carrying laws and instruments, not weights.
Case. The chirality and COM questions were closed with frozen wording and "no reopening without new hard evidence" (`frozen-verdicts-semantic-boundaries`); v5/v6's condemnations expired with the deploy stack (`stale-verdicts-under-old-stack`); a 2-degree calibration fix moved the whole runnable envelope (`zero-offset-calibration-shifts-envelope`); plant upgrades are era boundaries with paired re-baselining (`plant-swap-invariants-vs-shifts`); and the 2026-08-05 reset froze v5-v11, fixed the latency FIFO / manifest / sampling / reward-table debts, and restarted - producing the lineage that reached hardware SOTA (`freeze-lineage-fix-structure-restart`, `minimal-reward-table-with-provenance`). The recovery line's real-robot verdicts ended up in three places that disagree, one of them an undated note in a command file (`write-hardware-verdicts-back`).
Coach application. Maintain the closed-questions ledger and quote it when symptoms recur; stamp verdicts with stack/calibration versions; when a team is three rungs into symptom-shuffling, raise the restart question explicitly with the freeze-fix-restart pattern.
doctrine-21Name the quantity in the space it lives inA goal, reward term or acceptance criterion about the feet, the base or the contact state is computed from the quantity itself - world poses, forces, per-category outcomes - never through a joint-angle, single-signal or pooled stand-in that assumes everything else sits at nominal; and every detector is validated on a behaviour known not to contain the event before it becomes a gate.
Case. The recovery line was caught three times: |ankle roll| as "flat feet" sold stance width and the real robot slid into the splits, a hip-roll criterion was confounded by 50 deg of yaw, and the joint table said 0.271 m where the feet were 0.159 m apart; task-space terms produced the first flat, wide stance (`joint-space-proxy-for-task-space-quantity`). Flight detection lied in both directions across two lines - foot height flagged 40% false flight on a walking gait, contact force alone flagged slip chatter as hops (`contact-detector-single-signal-lies`). A pooled height average described a robot that did not exist - six in ten standing, four in ten sitting (`zero-partial-credit-is-not-an-iteration-problem`) - and the walking line had learned the same lesson on yaw rate (`heading-integral-not-body-rate`).
Coach application. For every reward term and gate row, ask what physical quantity it stands for and whether it is measured directly; flag joint-space or single-signal stand-ins for task-space goals, ask for a detector validated on a negative control, and split pooled metrics by category before reading them.
doctrine-22Continuation needs a live gradient; a release is chosen by a scanContinue a converged policy only on a change that creates a live gradient, on a short budget, with every checkpoint scanned on the transfer axis; choose a release by running the full battery over a band of checkpoints and stop on signals, never by taking the last one; and when edits to the terminal phase cannot move a behaviour, roll back and retrain with the constraint present from the start, keeping the order in which the lineage acquired its mechanisms as explicit curriculum phases.
Case. A continuation with no new gradient drifted MuJoCo transfer from 100/98% to 80/28% while every Isaac gate stayed perfect, and a live-gradient continuation at the same depth kept it (`converged-continuation-is-poison`). One-leg checkpoints 100 iterations apart failed 1 and 38 of 40 cells, and late ones degraded (`checkpoint-choice-is-a-full-gate-scan`). Four in-lineage stance fixes failed because the stance was the end of the get-up path, and from scratch it grew right (`stance-decided-by-get-up-path`); fixes stacked on degraded states were rolled back by the user (`stop-stacking-roll-back-and-audit`); and the lineage's final recipe, trained from scratch in one run, sat at 0% because the order of its curriculum was part of the product (`curriculum-history-is-part-of-the-product`). The omni line's short adaptation budgets and mature roots are the same law seen from the other side (`continuation-budget-not-from-zero`, `root-maturity-vs-product-quality`).
Coach application. Before approving a continuation, ask for the new gradient, the budget and the transfer axis in the scan; before approving a release, ask for the scan; after three rungs without progress on the target, propose rolling back to the last good checkpoint and a from-scratch phase plan instead of a fourth patch.
Experience cards
161 cards matching “reward-cost-of-ignoring-audit”.
Verify changes in the run's resolved config (and checkpoint md5), never in the source you edited
resolved-config-is-source-of-truthAttribution and single-variable claims must be made on the resolved per-run config (and checkpoint hashes), not on source diffs; verify every intended variable landed before burning compute, and verify every rollback byte-level against the historical resolved config.
Symptom
An intended arm-B config change never reached the training run - the run was grid-identical (117/117 cells) to its C2 predecessor - and the burn was only understood afterwards.
Context
The repo's discipline hardened around the logged resolved config (logs/<run>/params/env.yaml) as the only source of truth: (1) the C2 root-cause analysis was performed against the checkpoint's logged env.yaml, not the code ("以真相源 23-19-25/params/env.yaml 核实"); (2) C4 added a pre-flight: grep the landed env.yaml for the new keys, and compare the first checkpoints of the two arms - identical md5 means the variable did not land, stop immediately; (3) the C4 full rollback was accepted only after starting a 1-iter run and byte-comparing its resolved env.yaml against the historical 700-era file (identical except 4 dormant schema fields, each verified to be at its no-op default).
Change
Standing pre-flight and post-change verification: dump/diff the resolved config that the run actually consumed; use checkpoint hash equality as a cheap "variable landed" detector between arms.
Outcome
Caught the not-landed variable class of failure; made the rollback provably equivalent to the historical training state rather than believed-equivalent.
Mechanism
Between edited source and the running experiment sit layered overrides, env-var switches, and registration logic; only the resolved, serialized config reflects their composition. Diffing at that level tests the actual experiment; diffing source tests intent.
Applies when
- launching an A/B pair or any single-variable rung
- rolling back to a historical training state
- a run behaves as if a change was never applied
“开训前先验落盘 cfg(上一轮臂B 的改动没进 run,与 C2 逐格 117/117 相同):grep -E "base_com|joint_friction|push_robot|track_lin_vel_y_exp" logs/<run>/params/env.yaml 另:两臂第一个 checkpoint 的 md5 若相同 = 变量没进去,立刻停。”
train/C_LADDER_RUN.md § 3d. ⚠️ 开训前先验落盘 cfg / 3l. 回退清单(验证) An auto-curriculum ratchet capped out at iter 248 and never engaged - stage difficulty manually or verify engagement
auto-curriculum-engagement-checkPrefer manually staged difficulty with gated transitions; if you use an automatic curriculum, instrument its internal state and alarm when it stops engaging - a saturated curriculum is constant DR wearing a curriculum's name.
Symptom
A curriculum mechanism intended to grow difficulty adaptively (s1f's ratchet) hit its cap at iteration 248 and never bit again - for 96% of the run its effect was equivalent to constant DR, i.e. the curriculum existed in name only.
Context
When external advice suggested graded wz bands (start ±0.15, then ±0.30), the team agreed with grading but explicitly rejected automatic curriculum, citing the s1f episode. The same logic had already been paid for with push grading: ±0.6 failed twice, ±0.3 was feasible - grading matters, but the grade transitions were made by hand at verified checkpoints.
Change
Ladder policy: difficulty staged manually, one band per rung, each transition gated by the acceptance battery; automatic ratchets not used unless their engagement is monitored and demonstrated.
Outcome
Every C-ladder band change (wz ±0.12-0.25 first, wider later) was an explicit, attributable rung; no silent constant-DR-in-disguise runs recurred.
Mechanism
Adaptive curricula couple their own state machine to noisy training metrics; a ratchet that saturates early stops adapting but keeps its name, so the operator believes difficulty is progressing when it is frozen. Manual staging costs more decisions but each decision is observable and reversible.
Applies when
- choosing between auto-curriculum and staged bands for a new skill
- a curriculum's difficulty parameter plateaus early in training
- post-hoc attribution of what difficulty a lineage actually saw
“C2 的 wz 分级(±0.15 → ±0.30,不要一上来 ±0.6)—— 与我们付过学费的 push 分级同形(±0.6 两轮 FAIL,±0.3 才可行)。但必须手动分级,不做自动课程 —— s1f 的课程化棘轮 iter 248 封顶未咬合,96% 时长等价常量 DR”
train/C_LADDER_RUN.md § 1. 采纳 3 条 (C2 的 wz 分级) A suspended (no-load) test acquits or convicts the actuator before you blame authority
suspended-test-isolates-actuator-authorityBefore attributing a failure to actuator authority, measure no-load tracking error and steady-state torque fraction; blame authority only if the task fails while the error grows with demanded force - and then fix gains or targets, not training.
Symptom
hip_roll sagged 0.21 rad on the ground and saturation questions loomed over the sidewalk plan - was the roll axis physically too weak (authority), or was something else limiting it?
Context
Before C4, the roll-authority question was settled by measurement triage: suspended test (--suspend, feet off ground) showed hip_roll tracking error 0.0008 rad - actuator acquitted; the entire 0.21 rad ground sag is load-induced. Steady-state torque was 25% of limit - 75% margin remains. Since sidewalk needs lateral force, not exact angles, authority was ruled "not a hard limit", with a pre-registered criterion for when it WOULD become one: sidewalk fails to track AND roll error keeps growing - then the fix is raising hip_roll kp or lowering the vy target, not more training.
Change
Hypothesis "roll authority insufficient" demoted from blocker to a monitored branch with an explicit trigger condition; C4 proceeded.
Outcome
Later open-loop probes confirmed the actuator could produce the behavior (sidewalk feed-forward ran at full amplitude, 5/5 survival), and the eventual C4 failure causes were measurement and reward, never authority.
Mechanism
Suspended vs loaded comparison separates the actuator's closed-loop competence from the load path: tiny no-load tracking error means the motor/controller is fine and any loaded deviation is statics (gravity / stiffness budget, kp trading error for force). Torque-fraction measurement then bounds how much force headroom actually remains.
Applies when
- suspecting an axis is "too weak" for a new skill
- large position sag on a loaded joint
- deciding between hardware fix, gain change, and more training
“吊挂(--suspend)实测 hip_roll 跟踪误差 0.0008 rad → 执行器无罪,地面下垂 0.21 rad 全是负载所致;稳态占限扭 25% → 仍有 75% 扭矩余量。… 判据:若 C4 出现「侧走跟不动且 roll 误差继续变大」,那才是权限账 … 解法是提 hip_roll 的 kp 或降 vy 目标,不是硬训。”
train/C_LADDER_RUN.md § 3d. roll 权限:已部分澄清,不是硬上限 A field experiment is allowed when it is pre-scripted, single-variable, and self-reversing (RAM-only writes)
reversible-single-variable-field-experimentsPermit hardware-side experiments only when scripted in advance with one variable, a log, and automatic reversion (volatile writes, git restore); keep every config mirror (yaml vs firmware) changed and restored as a unit.
Symptom
A hypothesis needed a hardware test - v5's "wild kicking" might trace to the RS00 torque cap being deployed at 11 N*m vs its trained 14 (-21%), on exactly the ankle-roll/hip-yaw joints doing lateral-yaw work - but changing limits in the field is the classic way to lose track of robot state.
Context
The experiment was written to be safe by construction: change exactly one number (robot.yaml RS00 tau_limit 11.0 -> 14.0), write to firmware RAM only (--write without --save, so a power cycle automatically rolls back to the saved 12/17/11), run the single logged trial, then restore both yaml (git checkout) and RAM immediately. The consistency requirement is explicit: the deploy tool's torque self-check compares against robot.yaml, so yaml and firmware must change and restore together; and the hypothesis scoping is itself single-variable - RS06's 67% cut was measured irrelevant (gait uses only 16% of rated) and hip torque was left alone for safety.
Change
Field experimentation policy refined: not "never touch hardware settings" but "only pre-scripted, one-variable, logged, auto-reverting changes with config/firmware kept consistent".
Outcome
The sub-experiment could answer the torque-cap hypothesis without any risk of the robot persisting in an undocumented state - forgetting to restore costs nothing but a git checkout.
Mechanism
The danger of field changes is state divergence (robot config drifting from the repo's record), not the change itself; volatile (RAM-only) writes bound the divergence lifetime to one power cycle, and single-variable scoping preserves attributability even in a field setting.
Applies when
- a hypothesis requires changing firmware limits or gains on the robot
- field debugging tempts persistent config writes
- designing safe escape hatches for deployment tooling
“程序(--write 不带 --save = 只写 RAM,断电自动回滚)… deploy 的限扭自检是对 robot.yaml 比对的,所以 yaml 和固件必须同改同还原;忘了还原也没事,断电重启即回 12/17/11(上次 --save 的值),但 yaml 要 git checkout。”
train/REAL_SWEEP_V5_V8.md § 4. 限扭子实验(可选二期,只对 v5,单变量) Two machines, one configuration - every gain, offset and torque limit changes only in robot.yaml, whoever edits pushes at once, both checkouts show the same commit before the robot moves, and a pulled policy file is size-checked and synced before power-off
two-machine-config-disciplineTreat the robot's configuration as a versioned artifact with one source of truth, push every change immediately, verify identical commits on every machine before a hardware session, keep hardware limits in the repo and the firmware in sync in both directions, and verify transferred model files (size, digest) before running them.
Symptom
The robot's onboard computer runs the bridge and deploy scripts from its own checkout while training and analysis happen on other machines; a hot fix left on one side, or a half-written file, silently makes the robot run something other than what was evaluated.
Context
The operator runbook's "wall version" of the two-machine discipline: configuration changes only in robot.yaml (calibration offset/sign, gains, torque limits), committed and pushed from the Mac, pulled on the robot, bridge restarted; code is not edited on the robot, and if it is, it is committed and pushed on the spot - nothing unpushed overnight; 30 seconds before every real-robot session both checkouts must show a clean status and the same last commit hash; changing tau_max requires writing the motor's limit_torque too (and the reverse); re-zeroed motors require re-measuring offsets. The recovery line added: after pulling on the robot, check the ONNX is not zero bytes (a lesson from a corruption incident on 08-12) and sync before cutting power; the recovery and main lines are separate worktrees, each pulled with --ff-only.
Change
Operating rules, pinned on the wall and repeated in the hanging checklists ("git pull, both machines on the same commit").
Outcome
The sources record the rules and the incident that produced the size check; they do not record a count of sessions the rules caught.
Mechanism
A policy is evaluated against one configuration; any divergence between the machines, or a truncated file, turns a hardware result into a result about an unknown configuration.
Applies when
- a robot's onboard computer and a workstation both hold the configuration
- someone hot-fixes code or gains on the robot
- model files are copied or pulled to the robot before a session
“改配置只改 robot.yaml(标定 offset/sign、增益、限扭全在里面)→ Mac git commit + push → NX git pull → 重启桥。 … 谁改完谁立刻推,永远不留未推送的改动过夜。 … 每次上真机前 30 秒检查:两边 git status 干净、git log -1 哈希一致。 … 铁律不变:改 tau_max 必须同步写电机 limit_torque(反之亦然);电机重新标零后 offset 必须重测回填 yaml。”
RL系统/FOLLOW THIS copy 2.md § ② 双机维护纪律(贴墙版) Measure yaw rate by integrating heading, not by averaging body-frame angular velocity - the two differed 15x
heading-integral-not-body-rateFor any secular rate (turn gain, drift), integrate the world-frame angle over the window; never average instantaneous body-frame rates during oscillatory motion - and when code comments warn about a measurement, believe them before re-measuring.
Symptom
Two measurements of the same turn gain disagreed by a factor of ~15: time-averaged body-frame omega_z gave -0.05 while the sim2sim harness's heading-angle integration gave +0.473.
Context
The harness code comment had already documented and predicted the failure: during gait the torso oscillates (body-frame omega_z std up to 0.7); projecting world angular velocity onto a swaying body axis and then averaging biases the estimate systematically - "实测体系均值 −0.04 而实际在以 +0.15 转" (measured body-frame mean -0.04 while actually turning at +0.15). The author's own -0.05 measurement was declared void and the training machine's 1.58/2.45 turn gains confirmed valid.
Change
Measurement doctrine fixed: yaw rate for evaluation = net heading change by integration over the window; instantaneous body-frame rates are unusable for averaged directional statistics during legged gait.
Outcome
Subsequent friction sweeps and turn-gain accounting were all conducted in the heading-integral currency, making cross-simulator comparisons (MuJoCo vs Isaac 1.04/1.02) meaningful.
Mechanism
Averaging a vector quantity expressed in an oscillating frame couples the frame's oscillation into the mean (a rectification bias); the heading integral is computed in the world frame where the gait oscillation integrates to ~zero, leaving the secular component.
Applies when
- measuring turn gain, heading drift, or any secular angular rate
- a body-frame-averaged statistic disagrees with trajectory-level truth
- writing evaluation code for oscillating platforms
“我用体坐标系 ωz 的时间均值测,得 −0.05;sim2sim 用航向角积分,得 +0.473。差 15 倍。… 步态中躯干摇晃(体系 ωz std 可达 0.7),把世界角速度投到摇摆的体轴上再取均值会系统性偏掉 … 结论:偏航率必须用航向积分,体系瞬时角速度取均值不可用。”
train/WALK_DIAGNOSIS.md § ③ 转向增益 —— 我的测法是错的,训练机的 1.58/2.45 成立 Freeze the deployment contract, stamp every export, and let an automated checker catch wiring bugs
contract-freeze-and-checkerFreeze and fingerprint the policy I/O contract; ship contract changes as new versioned profiles that leave old artifacts bit-identical; and extend the automated contract checker with every pipeline change, forcing the new path to execute in the check.
Symptom
Contract-level changes (observation layout, action pipeline) are where silent sim/real divergence is born; two real wiring bugs appeared the one time the action pipeline was extended.
Context
The 215-dim observation contract was frozen ("纪元 3,三机 digest" - an era number plus a digest agreed across three machines); proposals that would break it (e.g. a GRU memory) were rejected on contract grounds. Every exported ONNX is stamped and verified with a manifest (onnx_manifest --stamp / --verify), and deployment refuses mismatched combinations. When C4 added the lateral feed-forward, it went in as a NEW profile (omni_ff) leaving the existing omni profile's behavior bit-identical; the checker (check_contract) was extended to force the feed-forward path to actually execute (cmd_vy=0.13) and promptly caught two genuine bugs: (1) re-clamping with soft_joint_pos_limits after the feed-forward (0.23 rad deviation) instead of reusing the parent's clip; (2) indexing processed actions by asset.joint_names instead of the action term's own contract-ordered _joint_names, which landed the feed-forward on the wrong joints (l_hip_yaw / r_ankle_pitch).
Change
Contract discipline as implemented: frozen dims + digest; manifest stamping and refusal; contract changes only via new versioned profiles; checker updated in the same commit as any pipeline change, with inputs chosen so new code paths are exercised.
Outcome
Both wiring bugs caught before any training or deployment ("两个都是 check_contract 当场抓出来的 —— 这次它值回票价"); old deployments provably unaffected by the new profile.
Mechanism
The contract is the only interface the policy and robot share; freezing plus fingerprinting makes divergence detectable, and an executable checker turns "the contract holds" from a belief into a test - but only if its inputs actually drive the new code path.
Applies when
- modifying the action or observation pipeline of a deployed policy
- exporting policies for hardware
- proposals that would change observation dims or history structure
“契约校验抓到的两个真错误(记账,别再犯):1. 前馈后误用 soft_joint_pos_limits(URDF 限位 ×0.9)重钳 → 0.23 rad 偏差 … 2. 用 asset.joint_names 索引 _processed_actions → 前馈落到 l_hip_yaw/r_ankle_pitch 上 … 两个都是 check_contract 当场抓出来的 —— 这次它值回票价。”
train/C_LADDER_RUN.md § 3j. 契约级改动 / 契约校验抓到的两个真错误 No parameter tuning on the floor - a failing config retries once, then it is out; anomalies go back to sim
no-field-tuning-protocolHardware time is for executing and measuring the pre-registered matrix, never for tuning: failing configs get one retry then elimination, anomalies get recorded and reproduced in sim, and contract-check bypass flags stay unused.
Symptom
Hardware sessions create pressure to fix problems live - nudge a gain, tweak a scale - which destroys attribution and risks the robot.
Context
The anomaly-handling section of the acceptance sheet is three fixed plays: (1) falls at start -> retry once at the same settings; falls again -> that configuration is eliminated, "不现场调参" (no on-site parameter tuning); (2) limit cycle or motor screech -> stop immediately, record the gain level and the joint, reproduce in sim before any discussion; (3) systematic disagreement with sim -> record it as a finding (hardware outranks sim) rather than adjusting anything to force agreement. Related guardrails elsewhere in the sheet: never pass --allow-unstamped / --allow-plant-drift to bypass manifest checks - if it errors, something real is wrong, stop and look.
Change
Field sessions restricted to executing the pre-written matrix; every fix path routed through sim reproduction and the normal config/rung process.
Outcome
Sessions stayed interpretable (each run matched a documented config) and safety overrides never became habit; anomalies arrived back in sim as reproducible cases instead of half-remembered floor stories.
Mechanism
Field-tuned values are measured under adrenaline on one floor with no logging or baselines - they contaminate the config lineage and are unattributable afterwards; and every bypass flag that skips a contract check converts a designed safety property into an operator promise.
Applies when
- a config fails or oscillates during a hardware session
- someone reaches for a live gain tweak or a bypass flag
- writing the anomaly-handling section of a deployment runbook
“起步即摔 → 换档重试一次, 仍摔则该档出局, 不现场调参。出现极限环/啸叫 → 立刻停, 记录档位与关节, 回 sim 复现再议。… 不要给 --allow-unstamped / --allow-plant-drift —— 三枚 ONNX 都已盖章 … 真要报错说明有别的问题, 停下来看。”
train/REAL_RUN_S2.md § 4. 异常处置 Slowing the gait clock at deployment is out-of-distribution and backfires - lower the commanded speed instead, or train the knob
cycle-time-override-is-oodAny deployment override must correspond to a dimension the policy was trained to handle; to make a parameter field-adjustable, randomize it in training and observe it - otherwise use the levers inside the trained envelope (commands) and leave the knob alone.
Symptom
Real-robot feedback "walks very fast and unstable" suggested slowing the gait; a deploy-side --cycle-time override existed, making "just slow the clock" a one-flag temptation.
Context
A sim sweep of the override on walk_v6 @cmd 0.3 showed monotone degradation away from the trained 0.40 s cycle: at 0.50 s tilt jumped 7.9 -> 13.2 deg and landing force 1.52x -> 2.24x; at 0.80 s (half speed) clearance collapsed to 3 mm - dragging again - with 20 deg tilt. Meanwhile the legitimate lever, lowering the commanded speed with the clock untouched, improved everything monotonically: cmd 0.1 gave 104% tracking, 6.7 deg tilt, minimum slip - the most stable operating point. The file distinguishes the two "slows" explicitly: lower command = smaller steps at the same 2.5 Hz rhythm; a slower rhythm itself requires retraining - randomize cycle_time (e.g. 0.40-0.65 s) during training and expose it as an observation, and only then does --cycle-time become a field-adjustable knob.
Change
Deployment guidance: never ship a cycle-time override the policy was not trained under; respond to "too fast/unstable" with lower commands; schedule clock variability as a training-time (contract-level) change if a field knob is wanted.
Outcome
The sweep quantified the trap before hardware paid for it (dragging and 2.2x landing force at slowed clocks); cmd 0.1 documented as the stable demo point.
Mechanism
The policy is a function fitted around the training distribution; a deploy-side override moves an input (phase rate) to values never seen, so behavior degrades unpredictably - the knob LOOKS like a capability because it exists in the code, but capability lives in the training distribution, not the interface.
Applies when
- a deploy tool exposes overrides (clock, scale, gains) beyond the training distribution
- hardware feels "too fast/aggressive" and a quick knob exists
- deciding between a deploy-side tweak and a retrain
“0.80s | 1.25Hz | 0.165 | 3mm(拖地) | 20.0° … 慢一半直接崩 … 策略按 0.40 训练, 别的周期属分布外。… 降指令速度才是有效杠杆 … cmd 0.1 是最稳的工作点。… 要节奏本身变慢必须重训 —— 训练期把 cycle_time 随机化(如 0.40~0.65s)并作为观测的一维, 部署时 --cycle-time 就成了现场可调的旋钮。”
train/WALK_DIAGNOSIS.md § 2026-08-01 追加: 调慢步态时钟(--cycle-time)在仿真里是反效果 A hardware run without its log is an anecdote - the first real get-up's policy, gain profile and log were never recorded, two CSVs stayed "to be reported", and runbook commands wrote different policies' logs under one copied filename
hardware-log-is-the-attribution-inputMake the log part of the run: name it from the policy and conditions automatically (never by hand-copied filenames), record the policy digest and gain profile inside it, include what the open questions need (torque, joint positions and targets), and treat a session without a collected log as incomplete.
Symptom
The recovery line's oldest open question - whether Isaac or MuJoCo reads torque demand correctly - was waiting on real-robot logs that never arrived, and the verdicts that did arrive could not be tied to files.
Context
deploy_policy writes a CSV per run (--log); the runbook's own analysis snippet reads its joint-position, target and action columns (q_, tgt_, act_), and the recovery hanging checklist asks for torque and joint logs for the whole run, to be compared with simulation. The first real get-up (08-09): policy, gain profile and log "to be recorded later". The first real A/B (08-11): v2_5b's result and both policies' CSVs "to be reported". In the runbook's walking commands, three runs of two different c4 policies log to real_s1e_pw08_teleop_0808.csv, and s1e and s2e_fric runs log to real_c2_700_pw08_teleop_0808.csv - filenames copied from other commands.
Change
None recorded; the spec kept listing the open-loop comparison as waiting for real logs.
Outcome
No real-robot log appears in the recovery spec through §50, so the simulator disagreement stayed unresolved and hardware verdicts stayed unattached to data.
Mechanism
Attribution needs the run's identity (policy digest, profile, conditions) and its signals in one artifact; a filename copied from another command mislabels the file, and a log not collected at the session is rarely collected later.
Applies when
- planning a hardware session whose result should settle a sim question
- log filenames are typed or pasted by hand
- hardware feedback arrives as prose without files
“python tools/deploy_policy.py --policy train/policies/omni_c4_ff800_pj.onnx … --log train/real_logs/real_s1e_pw08_teleop_0808.csv … q,t,a=d[:,c("q_")],d[:,c("tgt_")],d[:,c("act_")]”
RL系统/FOLLOW THIS copy 2.md § Walk 遥控 / S2 / csv 分析片段 (operator runbook, undated) When the eval proxy has a known systematic bias, gate on within-proxy differences, not absolutes
relative-metrics-survive-proxy-biasWhere the evaluator is known-biased, design gates as within-evaluator contrasts (left vs right, A vs B, pre vs post) that cancel common-mode error; reserve absolute thresholds for quantities whose proxy calibration has been checked.
Symptom
MuJoCo systematically overestimated yaw turn gain (1.58/2.45 where Isaac measured 1.04/1.02), and friction alignment recovered only part of the gap (mu 1.0 -> 0.6 pulled it to 1.43/2.27) - so any absolute turn-gain acceptance threshold in MuJoCo would be judging the proxy's bias, not the policy.
Context
The acceptance criterion was rewritten to use only the left/right difference of the turn gain (standard: <20%): both directions pass through the same biased proxy, so the bias largely cancels in the difference while the policy's chirality - the thing being gated - survives. The absolute-gain row was dropped: "转向只判左右差,不判绝对值". A parallel task was still opened to align MuJoCo contact parameters to Isaac's (mu, restitution), since drift proved highly friction-sensitive (straight-line drift -65 deg at mu 1.0 vs +1 deg at mu 0.4) - bias reduction and bias-robust metrics proceeded together.
Change
Gate metric changed from absolute turn gain to left-right gain difference; proxy-alignment work scheduled separately rather than blocking acceptance.
Outcome
Turn acceptance became meaningful across proxy versions (v5 70% -> v6 19% difference measured the real improvement) while the absolute bias question was pursued without holding the ladder hostage.
Mechanism
A systematic multiplicative or additive proxy bias applies to both arms of a mirrored measurement; differencing (or ratioing) mirrored conditions cancels the common-mode bias to first order, leaving the asymmetry signal. Metrics built this way remain valid while the proxy is imperfect - which it always is somewhere.
Applies when
- a sim proxy disagrees with the trainer or hardware in absolute terms
- writing acceptance thresholds for direction-paired skills
- proxy calibration work would otherwise block a ladder
“转向只判左右差,不判绝对值 —— MuJoCo 的偏航增益系统性高估(实测 1.58/2.45 vs Isaac 1.04/1.02),摩擦只能解释一部分(μ 1.0→0.6 仅拉到 1.43/2.27)。差值是相对量。”
train/WALK_V5_SPEC.md § 6. 验收 A real-robot verdict is (policy x deployment stack) - when the stack changes materially, old verdicts expire
stale-verdicts-under-old-stackDate every hardware verdict with the deployment-stack version it was measured under; after any material stack change, re-test before trusting old condemnations or old praises - with the interpretation of each possible result written down first.
Symptom
walk_v5 stood condemned as "kicks wildly" and walk_v6 as "cannot walk unassisted" - but those verdicts were issued under an earlier deployment stack (--heading did not exist yet, several fixes had just landed); only v7 had ever run under the current unified stack.
Context
New sim evidence sharpened the doubt: a same-harness four-version sweep showed v6 was the HEALTHIEST archive at the real operating point (cmd 0.15: dominant frequency locked at 2.50, steps 35:35 perfectly symmetric, foot distance 203/190 mm best of four, mean tilt 4.2 deg, saturation 15%). A full re-test under the unified stack was scheduled with per-version questions and a pre-filled interpretation table ("判读表(预填假设,回来对号)"): e.g. v6 walks + frequency ~2.5 -> old verdict was the stack's fault, v6 becomes the comparison champion; v6 walks but at ~1.25 -> period-doubling on hardware = confirmed plant gap, actuator fitting promoted to mainline; v5 no longer kicks -> the kicking was an old-stack artifact.
Change
All four versions re-queued on hardware under one stack (same torque limits, slew profile, heading loop, logging), with the version-specific legacy profile pinned; verdicts held provisional until re-issued.
Outcome
The re-test design separated policy properties from stack artifacts before any policy was permanently written off - and turned each outcome into a specific conclusion via the pre-filled table.
Mechanism
A deployed behavior is produced by the policy plus everything between it and the motors (heading loop, slew limits, torque caps, clock); verdicts implicitly condition on that whole stack. Fixing the stack invalidates the conditioning, so old failures may be stack artifacts and old successes may not survive either.
Applies when
- deployment tooling (limits, filters, loops) changed since a policy was last judged
- deciding which historical policy is the rightful baseline
- a sim sweep contradicts an old hardware verdict
“只有 v7 在完整的今日部署栈下上过真机 … v5"左右乱踢"、v6"未能自主"的判决全部来自更早的栈(--heading 尚不存在, 部分修复刚落地)——判决已过期。且 2026-08-02 四代同机仿真横测翻出了新证据:v6 在真机工况(cmd 0.15)下是四代里最健康的仿真档案”
train/REAL_SWEEP_V5_V8.md § 0. 为什么重测 Ideal PD is not enough - add a delay buffer and fit armature/friction/delay per joint
actuator-delay-buffer-fittingNever ship ideal PD to hardware: add a measured delay (in control steps) and per-joint armature/friction fitted from step and sine responses, and treat remaining actuator mismatch as your standing largest sim2real residual.
Symptom
Standard ideal PD actuator model transfers poorly; sim assumes targets take effect instantly and joints reach arbitrary acceleration.
Context
A developer with a successful on-hardware Isaac Lab biped modified the actuator model in two ways and calibrated it against the real robot: step-response plus sine-sweep tests (positive step, negative step, sine tracking), overlaying sim curves on measured curves and hand-tuning.
Change
(1) Delay buffer: action targets take effect after a uniform 6 time-step delay on all joints; (2) acceleration limiting so the actuator cannot reach arbitrary acceleration; (3) per-joint fit of armature / friction / delay - different joints genuinely needed different values.
Outcome
Hip joints fit worst, knee best; the developer rated the result "not perfect, the best I could do" and still listed actuator-model improvement as next work - i.e. even the fitted model remained the dominant residual.
Mechanism
Real actuation is a lagged, bandwidth-limited system; a delay buffer and acceleration cap are the two cheapest structures that reproduce its phase and magnitude response. Per-joint differences come from differing load, wiring, and friction states, so a single global constant underfits.
Applies when
- actuator model in sim is ideal PD with no delay
- step-response of real joint visibly lags or overshoots the sim's
- budgeting which sim2real gap to attack first
“标准 ideal PD actuator 不够用,他改了两处:延迟缓冲:目标不是立即生效,全部关节统一 6 个 time step 延迟 / 加速度曲线:执行器不能瞬间达到任意加速度 … 用 armature / friction / delay 三个参数逐关节拟合,标定方法是阶跃响应 + 正弦扫描 … 髋部关节偏差最大,膝关节最好。”
Experience.md § 执行器建模 —— 最值得抄的一条 (lines 50-59) The action-delay was implemented as lerp - beyond one step it extrapolated BACKWARD, so a whole lineage trained on a fictitious actuator
latency-lerp-reverse-extrapolationUnit-test plant-model code (delays, filters, randomizers) against hand-computed truth across its FULL configured range, not just the nominal case - a delay must be a queue, and any interpolation used outside [0,1] is a silent plant corruption that training will faithfully absorb.
Symptom
Every walk/stand model up to v11 had been trained on a silently wrong plant: the action-latency implementation lerp(cur, prev, lag) is only an interpolation for lag <= 1 - at lag 3 it computes 3*prev - 2*cur, a REVERSE extrapolation. With the configured (0, 0.06) s at 50 Hz (lag in [0,3]), about 2/3 of environments were adapting to actuator dynamics that do not exist.
Context
Listed as evidence item #1 for the full restart: "全部旧模型训在错误 plant 上" and the head suspect for the real robot's wild kicking. The fix replaced it with a true FIFO delay line (commit 7f13793) plus its own regression test (tests/test_action_latency.py) - but every exported ONNX predated the fix, which is part of why the lineage was frozen rather than patched.
Change
Delay implementation rewritten as an honest FIFO with unit tests; the restart baseline trained on the corrected plant from day one.
Outcome
A generation-scale training investment was revealed to have a corrupt plant underneath; the class of bug (plausible-looking math that silently changes meaning outside its valid range) got a permanent test.
Mechanism
lerp(a, b, w) leaves the segment for w > 1; used as a delay it fabricates high-gain inverted dynamics precisely in the largest-delay draws, so the policy learns compensation for an actuator that cannot exist - and DR then trains robustness to the artifact rather than to reality. No training metric can catch this: the sim is self-consistent, just wrong.
Applies when
- implementing or auditing action delay / filtering in a trainer
- a lineage behaves as if compensating dynamics nobody modeled
- deciding whether old checkpoints are salvageable after a plant bug
“动作延迟旧实现 lerp(cur, prev, lag) 在 lag>1 时是反向外插(w=3 → 3·prev−2·cur),配置 [0,0.06]s@50Hz 即 lag∈[0,3],约 2/3 env 在适应不存在的执行器动态。7f13793 已换真 FIFO,但所有 ONNX 均训于修复之前 —— 真机"乱踢"的头号嫌疑。”
train/OMNI_V0_SPEC.md § 0. 为什么从零 (1) Export every CAD part in the whole-machine frame so URDF rotations are zero and inertia is exact
urdf-shared-origin-exportGenerate the model so that correctness is structural: shared-origin STL export, zero rotations, subtraction-only origins, and an explicit 1e-9 g*mm^2 -> kg*m^2 conversion - never hand-rotate inertia tensors.
Symptom
Hand-assembled URDFs accumulate per-link rotation/origin errors and unit-conversion mistakes in inertia tensors - silent plant corruption that no later calibration can cleanly fix.
Context
Documented CAD -> URDF -> USD procedure from a successful Isaac Lab deployment, kept as the recipe if Lucen regenerates its model.
Change
(1) In CAD, align the whole robot to Z-up, X-forward (Isaac Lab convention) and ground the assembly; (2) export each STL with other parts hidden but the machine's shared origin kept, so all parts share one origin, every URDF rotation is 0, and inertia matrices equal CAD values directly; (3) units: Fusion 360 gives g*mm^2, URDF wants kg*m^2 - multiply by 1e-9; (4) link origin = negative of the joint position; link COM = CAD COM minus joint position; joint origin = difference of the two joint positions; (5) after URDF -> USD import, open the USD separately and set it instanceable before saving.
Outcome
A URDF whose rotations are all zero and whose inertia tensors are CAD-exact, eliminating an entire class of hand-transcription plant errors.
Mechanism
Keeping one shared origin turns every frame transform into a pure translation computable by subtraction, and leaves inertia tensors in the frame CAD already computed them in - no rotation of inertia tensors, the most error-prone manual step, is ever needed.
Applies when
- building or regenerating URDF/MJCF from CAD
- inertia or frame bugs suspected in the plant model
- importing URDF into Isaac Lab / USD
“导出 STL 时隐藏其他零件但导出整机——这样所有零件共享同一原点,URDF 里所有 rotation 全是 0,惯量矩阵直接等于 CAD 值 / 单位:Fusion 360 给 g·mm²,URDF 要 kg·m²,乘 1e-9 / link origin = 该关节坐标取负 … URDF → USD 导入后必须单独打开 USD 设成 instanceable 再存”
Experience.md § URDF 制作流程 (lines 87-92) Guessed joint friction was 2.5x low and damping 5x high - measure, then DR around nominal
friction-measured-not-guessedMeasure frictionloss and damping separately (they need different rigs), put the measured value at DR center, and express DR as an additive band around that nominal - a DR range around a guessed value can exclude the real robot entirely.
Symptom
Old MJCF friction values were invented, not measured; when finally measured, every guessed value was wrong by a large factor in some direction.
Context
Joint friction split into Coulomb (frictionloss, tau_c) and viscous (damping b). Measured with the robot hung from a crane (吊机测) while armature was measured no-load; the two measurements are deliberately separated. Old MJCF: frictionloss 0.05, damping 0.1, DR joint_friction range [0, 0.1] "凭空拍的" (made up out of thin air).
Change
Replace guessed values with measured ones - frictionloss: RS06 0.15 / RS02 0.12 / RS00 0.13 N*m (old 0.05, i.e. 2.5x too low); damping: 0.02 N*m*s/rad on all three motor types (old 0.1, i.e. 5x too high). DR reshaped from an absolute made-up range [0, 0.1] to an additive band around measured nominal: joint_friction_add [-0.05, +0.10].
Outcome
"摩擦定稿(与 armature 一起, plant 参数第一次全部来自实测)" - friction frozen as part of the first fully-measured plant; DR now brackets a measured truth instead of spanning an invented interval.
Mechanism
Coulomb friction and viscous damping have opposite behavioral signatures (constant-torque threshold vs velocity-proportional drag); guessing both wrong in opposite directions gives a plant that is simultaneously too easy to start moving and too hard to move fast. DR centered on a wrong nominal makes the policy robust to a family of plants that does not contain the real one.
Applies when
- plant friction/damping values have no measurement provenance
- DR ranges are absolute intervals rather than bands around a nominal
- policy is over- or under-damped on hardware relative to sim
“测关节摩擦。吊机测,而armature应该空机测试。… frictionloss τ_c (N·m) │ 0.15 │ 0.12 │ 0.13 │ 0.05(低 2.5×) … damping b (N·m·s/rad) │ 0.02 │ 0.02 │ 0.02 │ 0.1(高 5×) … DR │ joint_friction_add: [−0.05, +0.10] 叠标称 │ 旧 [0, 0.1] 凭空拍的”
Experience.md § 摩擦定稿表 (lines 12-25) Mirror augmentation over an asymmetric default injects systematic error - symmetrize the default first and verify the transform bit-exact
mirror-augmentation-needs-symmetric-defaultBefore enabling any symmetry augmentation, make every constant inside the observation encoding exactly symmetric, and validate the mirror transform against forward kinematics to machine precision - an unverified augmentation is a new error source, not a regularizer.
Symptom
Mirror data augmentation was about to be added while both default poses (standing_pose, walk nominal_pose) were asymmetric - stale hand-tuned compensations from before a ground re-calibration, with hip_yaw differing 2.40 deg between sides and the foot soles actually tilted (pitch 2.88/1.35 deg, roll -2.47/+0.25 deg).
Context
The observation encodes joint_pos_rel = q - default. Under mirroring q_l -> -q_r, the relation (q-default)_l -> -(q-default)_r holds only if default_l = -default_r; with an asymmetric default, augmentation produces observation pairs that are NOT mirror images, i.e. "default 不对称时做镜像增强会引入系统性错误,比不做还糟" (worse than not doing it). The fix: adopt model geometric zero as standing default (MuJoCo FK verified: sole pitch/roll exactly 0, asymmetry 0.00 deg) and a symmetric crouch for walk (hip -0.25/knee -0.5/ankle -0.25 satisfying hip - knee + ankle = 0 to keep soles flat). The mirror transform itself was verified bit-exact before use: pseudovector vs polar-vector sign patterns (ang vel [-1,1,-1], gravity [1,-1,1], cmd [1,-1,-1]), joint swap-and-negate; FK check that left-foot pose under q equals the mirror of right-foot pose under mirror(q), measured error 0.00e+00.
Change
Defaults symmetrized first (with init heights recomputed by FK), stand policy retrained on the new default so both policies share one default; augmentation enabled only after the FK mirror test passed.
Outcome
stand_v1 achieved exact left/right pairing (l_knee -0.1013 / r_knee +0.1013), six-pair asymmetry 0.0 deg, height fluctuation 7 -> 1 mm, 33% less mean |action|.
Mechanism
Augmentation asserts an equivariance of the observation encoding; any asymmetric constant inside the encoding (the default) breaks the asserted symmetry, so the augmented data teaches a false invariance. Verifying the transform against FK geometry tests the assertion end to end, independent of the training stack.
Applies when
- adding mirror/symmetry augmentation to locomotion training
- defaults or trims were hand-tuned per side at any point
- observations are expressed relative to a default pose
“观测里 joint_pos_rel = q − default。镜像下 q_l → −q_r,要让 (q−default)_l → −(q−default)_r 成立,必须 default_l = −default_r。default 不对称时做镜像增强会引入系统性错误,比不做还糟。… 位置误差与姿态矩阵误差实测均为 0.00e+00。”
train/RETRAIN_v2.md § 2. 前提:default 姿态必须先对称化(不是可选项) / 3. 镜像变换 Friction DR was demoted after a measurement (94% success at mu 0.4 with no friction randomization) and promoted again when the action contract changed and mu 0.4 fell to 76% - DR priorities belong to a plant and contract, not to a task
friction-priority-re-measured-after-plant-changeRe-measure transfer along the friction axis for every new action contract or plant, not once per task; a DR priority settled under one action parameterization does not carry to the next.
Symptom
Getting up is all scraping and pushing against the ground, and training pinned friction at 1.0, so friction looked like the first thing to randomize.
Context
The MuJoCo gate on R0.5 (5 categories x 10 seeds x 4 friction levels) measured 100/100/98/94% at mu 1.0/0.8/0.6/0.4: degradation showed first as time (prone 3.2 -> 5.3 s), not failure, so friction DR was demoted and the DR budget earmarked for mass/COM. After the switch to the beta-anchored action space, V2.2 read 90/94/90/76%: mu 0.4 was now the weak row.
Change
V2.3 (single variable): friction DR static (1.0, 1.0) -> (0.2, 2.0), dynamic (0.15, 1.6), the HiFAR range keeping the base dynamic/static ratio; restitution untouched. Continued from v2_2.
Outcome
Isaac nominal 99.8% (DR did not hurt the nominal plant); MuJoCo 98/98/96/92% - mu 0.4 76 -> 92%, mu 1.0 back to R3.1's 98% with bounded torque.
Mechanism
How much a policy leans on friction depends on how it moves; the spec records that the sensitivity rose after the action contract changed but does not establish why.
Applies when
- changing the action space, gains or authority of an existing skill
- deciding which DR axis to spend the next rung on
- an earlier sweep justified leaving an axis unrandomized
“**μ 砍到 0.4(训练值的 40%)仍有 94%**,退化先体现在**用时**(prone 3.2→5.3 s) 而不是成败。μ≥0.8 完全无损。→ **§17 曾把"摩擦随机化提到 R4 第一项"当作优先 事项,这条实测把它降级了**”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §21 MuJoCo 复核门 ② 摩擦依赖 Pre-register the ladder's risks and how each future result will be read - before training
preregister-risks-and-fork-readingsBefore a training ladder or risky rung, write the risks, the stop rules, and how every plausible outcome will be interpreted - then do not edit them after seeing results.
Symptom
Without pre-registration, ladder results get rationalized after the fact; the team had already seen post-hoc reads go wrong and adopted written pre-commitment.
Context
The C-ladder execution sheet opens with three numbered pre-registered risks: (1) S2 plant robustness will not carry into omni - a full S2 redo is budgeted from the start; (2) the s1e recipe has a collapse valley at iter 1500+ (recorded twice), so every rung runs a watch_ckpt --every 100 smoke loop with stop-on-degradation; (3) the root's OOD survival edge may partly be "it is slower / commits less" - with the reading fixed in advance: if C1 training raises tracking while survival drops, the edge was bought with slowness, and root selection reopens. Later rungs went further, pre-registering a full result-to-conclusion table for the A/B arms ("预注册读法(事后不改)") and even pre-registering the author's own doubt that a level would fail and what its failure would prove.
Change
Standing practice: before each rung, write down (a) known risks with their mitigations, (b) the interpretation of each possible outcome, (c) stop criteria - all frozen before the run starts ("开训前写死,事后不许改").
Outcome
When arm-A/arm-B and redo results arrived, conclusions were read off the pre-registered table instead of argued; a predicted-likely-FAIL level (C4-redo3) was still run because its pre-registered value was eliminating the regularization hypothesis - which it did.
Mechanism
Pre-commitment converts each training run into a decisive experiment: outcomes falsify or confirm named hypotheses instead of being absorbed into a story; it also makes negative results valuable (a FAIL that eliminates a hypothesis advances the search).
Applies when
- launching a multi-rung training ladder
- running an A/B fork whose outcome will drive a fork/root decision
- a rung is expected to fail but is run for its diagnostic value
“三条预注册风险 … 若 C1 训后跟踪提上去而存活掉下来,说明这条优势是速度买的、不是通用性 → 那时重开选根。”
train/C_LADDER_RUN.md § 0. 三条预注册风险 Teleop fed the sidewalk axis a command beyond its training band - feet clipped; give each axis its own speed setting
teleop-command-band-per-axisGive every command axis its own teleop scale, clamped to that axis's training band, and reproduce any hardware incident in sim with the exact deployed command values before touching training.
Symptom
Robot stepped on its own foot when sidewalking left under teleop - and only when going left.
Context
The teleop tool used one speed setting for all axes: --teleop-speed 0.20 applied to A/D sent cmd_vy = 0.20, above the training band's top (0.08-0.18) where foot-spacing margin is thinnest. Sim reproduction of the incident (product policy, pw0.8, 5 seeds x 20 s, true collision threshold = single foot width 104 mm): at vy 0.20 the minimum foot distance was 111-115 mm - 7-11 mm from self-collision - vs 147 mm at vy 0.10. Left was 4x more dangerous than right (25% vs 6% of time inside the 160 mm soft wall at vy 0.10), matching the left-only symptom; the margin did not degrade over time (pressing more just lengthened exposure).
Change
deploy_policy gained --teleop-side (default 0.10), separating the lateral speed from the forward speed so each axis's teleop command sits inside its own trained band.
Outcome
Command now inside the band with 43 mm margin at default; the incident became a quantified, reproduced, closed account rather than a mystery.
Mechanism
The policy's competence envelope is the training command distribution per axis; teleop mappings that share one scalar across axes silently command out-of-band inputs on the weakest axis. Asymmetric risk (left vs right) came from the policy's own chirality bias, so a symmetric command produced an asymmetric hazard.
Applies when
- wiring a joystick/teleop layer over a learned policy
- a hardware incident occurs on one command direction only
- training bands differ across command axes
“A/D 一直与 W/S 共用速度档,所以按 A 下发的是 vy = 0.20 —— 既超训练带(0.08~0.18)上沿 … 0.20(遥控实际值)| 111~115 mm | 7~11 mm … 且左比右危险 4 倍 … 处置:deploy_policy 新增 --teleop-side(默认 0.10),侧移与前进档分开。”
train/C_LADDER_RUN.md § 3p. 一 向左走踩到自己 → --teleop-speed 0.20 同时喂给了 vy A pull-assist curriculum keyed to a global success share was satisfied by the categories that already worked and withdrew before prone learned anything - conditioning the criterion on prone took it from 2.5% to 98.7%
curriculum-criterion-conditioned-on-lagging-categoryMeasure a curriculum's advancement criterion on the population the scaffold is meant to help; a global success share is met by whatever already works, and the help is withdrawn before the lagging case learns.
Symptom
Under the beta-anchored action, supine and side stood reliably while prone still sat (1.3%). A pull-assist curriculum added to help it was withdrawn completely within ~790 iterations and prone moved only to 2.5% (noise).
Context
The pull assist follows HoST: an upward force on the base, active only when the torso is within 30 deg of vertical, scaled by body weight (HoST's 200 N on G1 = 0.583 BW -> 56 N here, steps of 5.6 N, ten levels to zero); the product must pass with no assist. It had already taught sit-to-stand in V1. In V2.1 its advancement criterion was the standing-time share over all envs (threshold raised to 0.55 because the share was already ~0.53).
Change
V2.2: PullAssistForce with gate_category = "prone" - only envs whose first step classifies them as prone count toward the criterion - and the threshold back at 0.35. A feasibility signal was pre-registered: if prone's share stayed near zero under the full 56 N, return to the roll-over path instead of adding force.
Outcome
The prone-conditioned curriculum withdrew level by level only as prone itself passed: prone 98.7%, and the four-category gate passed for the first time on the line (98.6% overall, re-falls 0%, torque gate PASS).
Mechanism
A pooled success share is filled by the categories that already succeed (supine/side ~53%), so the scaffold is removed on their account before the lagging category has used it.
Applies when
- an assist, guide force or easier setting is withdrawn by a success threshold
- one task category lags while the pooled metric looks healthy
- a curriculum ran to completion without changing the lagging category
“**教训:全局站立占比阈会被存量类别(supine/side ~53%)凑够,拉力在 prone 学会前就撤光了 —— metric 设计失误,不是拉力机制失效**(它在 V1 教会过 坐→站)。 … **V2.2(已启动)**:`PullAssistForce` 加 `gate_category="prone"` —— 达标判据 只统计 prone 类 env”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §34 V2.1 判决(2026-08-10) Low-friction robustness traced to kd DR bandwidth, not friction training - by digging resolved params across 8 lineages, 3840 cells
kd-bandwidth-mu-law-attributionAttribute capability differences by tabulating every lineage's resolved training params and eliminating zero-variance and non-aligned columns first; never let an eval-side override knob serve as the explanation axis, and never write a mechanism into a law before it survives a targeted test.
Symptom
Lineages differed wildly in low-ground-friction survival, and the intuitive explanation - "some trained ground friction, some didn't" - was about to steer the ladder toward a ground-mu training rung.
Context
The attribution ran as a full parameter-vs-result cross: 8 lineages x 4 eval kd levels x 6 mu levels x 20 seeds = 3840 cells, with each lineage's RESOLVED training params dug out and compared item by item. First kill: all 8 lineages had ground mu pinned at (1.0,1.0) - zero variance - so low-mu differences cannot come from friction training at all. The only training parameter aligned with the mu score was kd DR bandwidth: narrow (<=0.24) lineages scored 19.9/19.5/19.5, wide (>=0.40) scored 17.1/15.2/14.6/14.2/12.8 - the two groups completely non-overlapping. Every rival was excluded item by item (kd center no; kp band no; COM small-beneficial non-driving; friction rung a clean double null 19.5->19.5 and 15.2->14.6; iteration count non-monotonic), and the one clean single-variable causal link confirmed it: the s2e-3 kd surgery (0.7,1.3)->(1.08,1.32) moved the score 17.1->19.5. Counter-proof against "each best at its own operating point": the narrow-band lineage evaluated OUT of band (18.2) still beat the wide-band lineage at its own band center (9.2). Two axes were ordered never to be conflated (the first attribution's own error): training kd bandwidth is a parameter axis / lineage property; the eval-side --kd-scale knob is a plant axis (more damping physically helps on slippery floors for ALL policies) - "plant 轴只能当部署缓解,不能当 归因". A tempting mechanism story ("drag vs step attractor") was tested and falsified, and explicitly kept OUT of the law: "机制未定, 不入定律".
Change
The planned ground-mu training rung was recommended closed ("建议 不开") in favor of a kd band-narrowing rung (0.8,1.2)->(0.9,1.1) centered on the deployed value - with a pre-registered risk that the law demands "bandwidth = measured dispersion" and the real robot's kd dispersion was not yet measured; if it exceeds +/-10%, narrowing sacrifices real coverage and the rung must yield.
Outcome
A whole training rung was deleted from the ladder by attribution alone (the second S2 pass dropped mu and push, 5 rungs -> 3); floor material became a deployment-selection input (mu <~0.6 -> deploy the kd1.2 gain profile) rather than a training target.
Mechanism
Cross-lineage performance differences must be attributed over the actual training-parameter table, not over eval knobs or plausible stories: eval knobs act on the plant for every policy (a physical effect), while lineage properties come only from training-time parameters. Zero-variance columns are free eliminations, and one clean single-variable rung is worth more than any correlation.
Applies when
- explaining why lineages differ on a robustness axis
- an eval-side knob (gain scale, power) changes results and invites misattribution
- deciding whether to open a DR rung for an axis never actually varied in training
“8 血统地面 μ 训练带全部钉 (1.0,1.0) 零方差,低 μ 差异与「训没训地面摩擦」无关,是 kd DR 带宽的副产物 … 宽 ≤0.24 → 19.9/19.5/19.5;宽 ≥0.40 → 17.1/15.2/14.6/14.2/12.8, 两组完全不重叠。… 训练 kd 带宽 = 参数轴/血统属性;评测部署 --kd-scale = plant 轴 … plant 轴只能当部署缓解, 不能当归因。… 机制未定, 不入定律。”
train/OMNI_V0_SPEC.md § 4. 地面 μ 鲁棒性 = kd DR 带宽的副产物 (2026-08-08) The real robot's right-leg kicking was over-trained-delay times loop gain - irreducible pipeline latency is plant, model it fully from day one
pipeline-latency-is-plant-not-drMeasure the end-to-end action pipeline delay and build it into the nominal plant and every acceptance gate from day one; treat power/scale deratings that "fix" oscillation as gain-reduction crutches flagging an unmodeled delay, and expect higher-feedback-gain policies to be MORE delay-fragile.
Symptom
On hardware, s1c/s1d at action scale 1.0 always kicked wildly with the right leg (s1c only ran as SOTA at power 0.8; s1d only at 0.7) - while sim showed nothing under default evaluation.
Context
Sim reproduced the incident item by item once the real pipeline delay was injected: s1d@1.0 with --delay 1 fell at 10.2 s, --delay 2 at 5.2 s; s1c@1.0 stressed (r_hip_roll saturation 5 -> 16%; "右脚" = the policy's chirality makes the right leg its high-gain leg); and the combos that worked on hardware (s1c@0.8+delay2, s1d@0.7+delay2) all survived in sim. Mechanism: the real pipeline is ~1-2 ticks (BusWorker next-cycle pickup + CAN round trip) but S1.1 trained only to 1 tick - "超训延迟 × 全环路增益 = 振荡;衰减 = 压环路增益换稳定" (delay beyond training x full loop gain = oscillation; the power derating had been buying stability by compressing loop gain). s1d was MORE fragile than s1c because its yaw 3-layer stack had learned higher feedback gain - higher gain, lower delay tolerance. Three changes: latency DR widened to cover reality; acceptance gates and smoke runs moved permanently to --delay 2 ("门必须在真机条件下预测 真机"); and the doctrine written twice-paid: "不可约的管线属性(延迟、 限速)不是'随机化选项',是 plant 本体,第一天就该全额建模" - S1's nominal-then-robust staging falsified by hardware for the second time. The later s1e hardware run at power 1.0 (no kicking, normal force) closed the loop: "0.8 = 旧代拐杖" - the derating had been a crutch for the under-modeled delay, not a real requirement.
Change
Latency modeled as plant from day one of any lineage (measured 1-2 ticks covered, bridge-layer rate limits likewise modeled by default); every gate and smoke evaluation issued under --delay 2.
Outcome
Kicking reproduced, explained, and eliminated in the s1e generation at full scale and full power; the deploy-side crutches (0.7/0.8) retired for the new lineage.
Mechanism
Feedback oscillation onset is a product of loop gain and phase lag; a policy trained below the real delay learns gains that sit past the real stability margin, and any output derating masks it by scaling gain down. Since pipeline delay is deterministic hardware property - not an uncertainty - it belongs in the nominal plant, and every evaluation must include it or the gate predicts a robot that does not exist.
Applies when
- hardware oscillation/kicking that sim only reproduces with added delay
- a policy only runs on hardware at reduced power/scale
- defining what belongs in the nominal plant vs the DR list
“真实链路延迟 ~1~2 拍 … S1.1 只训到 1 拍——超训延迟 × 全环路增益 = 振荡;衰减 = 压环路增益换稳定。s1d 比 s1c 更脆 = yaw 三层栈学出更高反馈增益,增益越高延迟容忍越低。… 教训入账:S1「先标称后鲁棒」第二次被真机证伪——不可约的管线属性(延迟、限速)不是"随机化选项",是 plant 本体,第一天就该全额建模。”
train/OMNI_V0_SPEC.md § 3. S1.4(真机右脚乱踢事故强制) A ratio metric flipped the verdict - spectral share rose while absolute high-frequency energy fell 16%
ratio-metrics-need-absolute-checkNever compare share/percentage/centroid metrics across conditions whose totals differ; pair every ratio with its absolute numerator before issuing a verdict, and log retracted judgments so they are not re-derived.
Symptom
walk_v6 was provisionally judged "more jittery" than v5 because the joint-velocity spectral centroid rose 2.91 -> 3.62 Hz and the >4 Hz energy share rose 12.6% -> 17.8%.
Context
Absolute measures said the opposite: first differences of actions fell 1.54 -> 1.31, second differences 2.55 -> 2.19, and absolute high-frequency energy fell 16% (0.490 -> 0.413). The shares and centroid rose only because low-frequency content fell even more - the denominator shrank. The interim judgment was retracted in writing so it would not be reused.
Change
Metric discipline noted: "占比类指标在总量变化时不能直接比较" - share/ratio metrics are not comparable across conditions when the total changes; verdicts about smoothness must cite absolute energies or difference norms.
Outcome
v6 correctly classified as smoother, not jitterier; the retracted judgment logged under "被推翻的一个中间判断(记下来免得复用)".
Mechanism
A ratio confounds numerator and denominator; any intervention that removes low-frequency content raises every high-frequency share without adding a single joule of jitter. Only absolute quantities support cross-condition comparison when totals move.
Applies when
- comparing smoothness/jitter/spectral metrics across versions
- any percentage-based metric moves after an intervention
- writing an eval report that includes normalized quantities
“我一度说"v6 动作更抖" … 错了: 动作一阶差 1.54→1.31、二阶差 2.55→2.19 都在降 … 谱质心升高只是因为低频成分掉得更多, 绝对高频能量实际下降 16%(0.490→0.413)。占比类指标在总量变化时不能直接比较。”
train/WALK_DIAGNOSIS.md § 过程中被推翻的一个中间判断(记下来免得复用) The deploy-side walk/recovery switch - into recovery at tilt > 65 deg held 0.3 s, back at tilt < 15 deg with angular rate < 1 rad/s and straight knees held 1 s, a 15 s timeout, last action cleared both ways - and the handoff steps the design required are only partly implemented
walk-recovery-fsm-handoffSpecify a deploy-time controller switch as hysteretic, time-filtered predicates the robot can measure (proxy what it cannot, e.g. straight knees for height), a timeout that ends in a safe stop, and a complete handoff (history, clock, last action, command ramp) - then test that the code performs every handoff step, because the design document is not the implementation.
Symptom
With a recovery policy and a locomotion policy as separate networks, the robot needs a switch: when is it "fallen", when is it "up", and what state must be reset so the next policy does not act on the previous one's history.
Context
The 08-09 design: enter recovery when fallen (tilt > 55 deg or height < 0.60 x 0.384 m) for 150 ms, leave for a stand-hold when upright (tilt < 12 deg, height > 0.85 x 0.384 m, feet steady, |omega| < 0.8) for 400 ms - wide entry, strict exit, hysteresis - then a mandatory handoff trio before walking resumes (reset the walking policy's observation history, restart its phase clock at 0, clear its previous action and latency buffer) and a command ramp instead of a jump. The 08-14 implementation in deploy_policy (--recovery-policy): each policy under its own manifest contract (walk: nominal + scale; recovery: beta-anchored), the same rl_default gains, the tilt cutoff disabled; RECOVERY at tilt > 65 deg for 0.3 s; LOCO again at tilt < 15 deg and |omega| < 1 and knees straight (< 0.35 rad) for 1 s - the robot's computer has no height estimate, and straight knees stand in for height so a V3.0-style upright kneel cannot pass as standing; RECOVERY longer than 15 s ends in a safe stop; last_action cleared on both switches; command forced to 0 during RECOVERY; power scaling applies to LOCO only.
Change
An open account was written down with it: the recovery end state (0.355 m stance, hip yaw -/+27 deg) is outside the walking policy's training start distribution, so the first test must use stand / zero command as LOCO, and the long-term fix is to widen the walking policy's initial states rather than bend recovery's stance to suit walking.
Outcome
The spec records only a successful compile (py_compile); the hang test was left to be done on site. The operator runbook carries the three-step procedure (hang with stand as LOCO, mat and push, then omni walk as LOCO) but no outcome.
Mechanism
Two policies trained separately each assume their own history, clock and last action; a switch that carries any of them across feeds the next policy a state it never saw - the design called this "the walking policy seeing a ghost history".
Conflicts
The 08-09 design requires resetting history, clock and previous action plus a command ramp; the 08-14 implementation records last_action clearing and a zero command during recovery; the one-leg spec of 2026-09-14 lists the handoff hygiene as specified but not implemented - reset_history() is called by nothing (a 215-dim policy would carry four frames of pre-fall history), the phase clock is not zeroed, and there is no command ramp back to LOCO. No hardware run of the FSM is recorded in either source.
Applies when
- switching between separately trained policies on hardware
- a policy with history or phase observations is re-enabled mid-run
- the robot lacks a sensor the switching criterion was designed around
“**判据**:进 RECOVERY = 倾角 >65°(`--fall-tilt-deg`)持续 0.3 s;回 LOCO = §5 真机可测子集:倾角 <15° ∧ |ω|<1 ∧ **膝直 <0.35 rad(NX 无高度观测, 高度门用膝直代理 —— 防 V3.0 型"跪坐但直立"误判)** 持续 1 s (`--recover-hold`);RECOVERY 单次 >15 s(`--recovery-max-time`)安全停。 … **切换卫生**:两向切换 last_action 清零;RECOVERY 态 cmd 强制 0”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §50 FSM 双策略调度(2026-08-14,用户令):deploy_policy --recovery-policy Cross-simulator gate (Isaac Lab to MuJoCo) comes before any hardware attempt
sim2sim-gate-before-sim2realGate every policy through a second simulator with an independently built plant before hardware; treat sim2sim failure as a contract or overfitting bug, and sim2real failure after a sim2sim pass as a plant/actuator gap.
Symptom
A policy that only ever ran in its training simulator carries untested dependencies on that simulator's solver, contact model, and defaults; the first place those dependencies surface should not be the real robot.
Context
Standing order of operations for the whole Lucen program, recorded as the opening line of the experience log: train in Isaac Lab, gate in MuJoCo, only then go to hardware. The MuJoCo side is the same plant used for evaluation batteries, so a sim2sim pass also validates the exported policy + contract (obs ordering, scales, defaults) outside the training stack.
Change
Pipeline rule adopted - every checkpoint must pass the MuJoCo evaluation battery (sim2sim) before it is considered for real deployment (sim2real).
Outcome
Used generation after generation as the cheap filter; hardware sessions only ever received policies that had already survived a second simulator.
Mechanism
Two simulators disagree exactly where a policy is overfit to simulator-specific artifacts (contact softness, integrator, default parameters, obs conventions); a cross-sim transfer catches contract bugs and solver overfitting at zero hardware risk, so real-robot failures that remain are attributable to genuine plant/actuator gaps.
Applies when
- planning the path from training to first hardware trial
- exported policy behaves differently outside the training framework
- triaging whether a real-robot failure is contract vs plant
“先sim2sim - 从isaaclab 到mujoco / 再sim2real”
Experience.md § opening lines (1-2) Three same-shaped judging errors - task metrics (survival, tracking, displacement) cannot stand in for posture metrics
task-metrics-vs-posture-metricsKeep validated posture-class rows (tilt, per-joint L/R asymmetry, temperature) in every acceptance battery alongside task rows; when operator feel contradicts the gates, suspect the metric class before the operator - and never build a new skill on what is actually an asymmetry defect.
Symptom
The C2 product judged "full pass" on task metrics (A800: turn-gap 7 pp, vx+0.30 19/20) felt WORSE in the operator's hands than the half-pass 700: A800 tilted up to 12.90 deg (700: 6.64), drifted left while standing, showed larger per-joint asymmetries, and ran its hip_rolls 5 degC hotter.
Context
The re-judgment catalogued three same-type metric errors in one campaign: (1) stand judged by SURVIVAL - missed 0.5-1.4 m wandering; (2) stand ranked by DISPLACEMENT - ordering was opposite to real feel (tilt ordering matched); (3) chirality judged by wz-tracking GAP - measured turning symmetry while the robot's actual disease was postural left/right asymmetry, "两个不同的东西,且结论相反". Common pattern named: "我一直用「任务指标」当判据,而真机手感对应的是「姿态 指标」… 任务类指标不能替代它". The fix was already in the data: the per-joint left/right asymmetry table (printed identically by sim2sim and deploy) agreed with hardware in direction on every row - "判据可用、有预测力,我只是没把它写进 PASS 条件". Shipping decision followed the posture read: product reverted to 700 ("又一次「买到 精度、卖掉别的」"), and the C4 root moved to 700 as well, with the sharpest line of the episode: A800's left-drift "like sidewalking" is probably its frontal-plane asymmetry defect, not a capability - "在缺陷上建能力是危险的".
Change
Two posture quantities with demonstrated real-robot predictive power promoted into every PASS battery: tilt-max median and per-joint left/right asymmetry (both sim-computable, deploy-homologous); motor-temperature readout added to session close-out.
Outcome
Deployment flipped to the posture-better checkpoint; the hip_roll temperature table (43-48 degC vs 25-28) confirmed the earlier 90%-of-heat account; the run-line acceptance battery inherited the posture rows from birth ("任务类替代不了姿态类").
Mechanism
Task metrics measure goal attainment under the evaluator's episode definition; posture metrics measure the body state trajectory that operators, motors, and downstream skills actually experience. The two can rank candidates oppositely because task success tolerates postural pathology - so a battery without posture rows is blind to exactly what hardware feel reports first.
Applies when
- hardware feel disagrees with a green acceptance table
- choosing between checkpoints that split task vs posture metrics
- selecting the root for a skill that resembles an existing defect
“共同模式:我一直用「任务指标」(存活 / 跟踪率 / 位移)当判据,而真机手感对应的是「姿态指标」(倾角、逐关节左右不对称)。→ 验收判据里必须有姿态类指标,任务类指标不能替代它。… A800 的「左飘像 side walk」很可能 … 是它更大的额平面不对称的表现 —— 在缺陷上建能力是危险的。”
train/README.md § C2 选点改判 (2026-08-09): 手性判据第三次选错指标 A constant-value plant rung passed every binary gate with record scores - and shipped 60% thinner posture margins that hardware exposed
constant-value-dr-overfits-marginRandomize deployment-critical axes over a narrow band spanning the measured real support - never a single value, never a fictitious tail - and report graded margin quantities (tilt margin) next to binary gates, because saturated gates rank thin-margin and thick-margin policies identically.
Symptom
s2_lag1 (trained at constant 1-frame latency) posted the strongest sim gate sheet in history (20/20 everywhere) yet was unstable on hardware, while s1e (trained across the full 0-3 frame band) was the every-run-stable SOTA at the same power.
Context
The sim autopsy (new --delay-jitter harness modeling the BusWorker's time-varying phase drift): 18 runs across constant and time-varying delays ALL survived - time variation alone does not kill - but the tilt-margin ordering reproduced hardware exactly: s1e 7.7-9.1 deg (thickest) < s2_lag1 10.7-15.0 < s1c 16.2-18.2. Attribution: constant-value training permits precise specialization to that one value; s1e's band diversity forced cross-value robustness - "恒定 1 帧训练 vs s1e 的 0~3 帧全带——分布多样性逼出跨值鲁棒,恒定值允许精确 特化" - so the constant-rung policy's margins were ~60% thinner, fine in sim's clean world, pushed over the line by real-world disturbances. Tool lesson booked: "存活门二值饱和后掩盖裕度差" - binary survival gates saturate and hide margin differences; graded margin columns (tilt-max) belong in the report. The synthesis with the opposite failure (wide tails cause drag-glide): the proposed resolution was a NARROW uniform band (0.02, 0.04) covering exactly the real 1-2 ticks - diversity inside the measured support, no tail, no single point. s1e's root selection later leaned on the same property: its full-band latency training "预装" the delay rungs and delivered "全工况稳定裕度" that survived power derating.
Change
DR-on-an-axis design refined to a three-way distinction: no wide fictitious tails (drag), no single constant values (thin margins), but a narrow band spanning the measured real support; acceptance reports gained graded margin columns alongside binary gates.
Outcome
The tilt-margin column entered the standard report; the s1e root (band-trained) carried the C ladder while the constant-value branch was archived with its three contributions credited.
Mechanism
Robustness margins are shaped by the diversity of the training distribution, not just its support: a point-mass distribution lets the optimizer trade margin for on-point performance, while a band forces solutions that keep margin across the band - and binary survival metrics cannot see the difference until the margin is spent on hardware.
Conflicts
The narrow-band (0.02,0.04) resolution was a pending recommendation ("裁决建议(待用户)") at the time of writing; the lineage instead moved root to s1e whose full-band training predated the staged ladder - the deterministic-staging card and this card record the two failure modes the final design must avoid simultaneously.
Applies when
- a rung trained at a fixed plant value aces sim but wobbles on hardware
- binary acceptance gates are all saturated across candidates
- choosing between constant, banded, and wide DR on one axis
“18 跑全活,时变性单独不足以击杀;但 tilt_max 裕度排序完整复现真机:s1e 7.7~9.1°(最厚)< s2_lag1 10.7~15.0 … 恒定 1 帧训练 vs s1e 的 0~3 帧全带——分布多样性逼出跨值鲁棒,恒定值允许精确特化 … 存活门二值饱和后掩盖裕度差(s2_lag1 sim 门 20/20 史上最强却真机不稳)”
train/README.md § s2_lag1 真机不稳 × s1e 稳的 sim 对拍(2026-08-07,时变延迟实验) A plateau in a training curve was a population mix, not a half-learned skill - 60% standing at 0.372 m and 40% sitting at 0.19 m - and a category at hard zero stayed at zero through 3,000 more iterations
zero-partial-credit-is-not-an-iteration-problemBefore buying iterations for a plateau, split the metric by category and check whether it is bimodal; a category at hard zero with no partial credit is missing a capability or a reachable state, and more iterations under an unchanged config will only polish the categories that already work.
Symptom
After R0.1 the training-side base_height sat near 0.29 m and the curve was still climbing at the iteration cap, which read as "train it longer".
Context
Candidate A (user decision) was a child-run from R0.1's last checkpoint with zero config change - the logged env.yaml files differ only in log_dir - for 3,000 more iterations (R0.2). The per-category acceptance split was already available: prone had scored 0/156 with no partial credit.
Change
Continue training unchanged, then read the result by category rather than by the pooled curve.
Outcome
supine 91.5 -> 96.4%, side 82.2 -> 87.9%, get-up 0.96 -> 0.84 s, pose error 0.91 -> 0.54 - all improvements to categories that already stood. Prone stayed 0/153; mid 55.9 -> 41.2% was within noise (n=34). Height by category was binary - standing groups 0.372/0.373 m, seated groups 0.187/0.194 m, nothing between - so the pooled 0.29 was 0.61 x 0.372 + 0.39 x 0.19 = 0.30 (measured 0.307): six in ten standing, four in ten sitting. The rendered prone episode was still kneel-sitting at t = 8 s.
Mechanism
The pooled mean of a binary outcome only moves when the mix moves; PPO kept polishing the subpopulation that already succeeded while the failing one produced no advantage signal to follow.
Conflicts
R0.2 recorded the missing capability as "prone lacks rolling over"; R0.3's end-state confusion matrix retracted that - prone had righted its torso in 159/159 episodes and was failing to stand from the W-sit. The lesson that iterations could not fix it holds; the named cause was wrong.
Applies when
- a training curve plateaus while acceptance shows one category at zero
- deciding between "train longer" and "change something"
- pooled training metrics are read as the typical episode
“**分类别 h 中位把"平台 = 人口混合"钉死了**:数值是**二值**的 —— 站立组 0.372/0.373,坐姿组 0.187/0.194,**中间没有过渡态**。 … **这也是本仓此后读该指标的通用告诫:全体混合的期望会把 双峰分布平均成一个不存在的中间值,必须分类别看。** … **结论:A 不能过门,原因确定为 prone 缺"翻身"这一技能,不是迭代不够。**”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §13 R0.2(recovery_r0_2,child-run 续训):A 走完了 —— 推不动 prone Score left and right separately - averages hide chirality breaking that mirror augmentation does not prevent
chirality-scored-separatelyReport every mirrored skill as two numbers with an explicit gap budget; never accept an average, and never assume augmentation guarantees symmetry - measure it per lineage and treat breakage as hard to reverse.
Symptom
Policies developed quantified left/right asymmetry (e.g. C2-700 turned right at 82% but left at 67% - a 15 pp gap; push tolerance 40/40 symmetric on the root vs 17/40 on a deep-trained descendant), and averaged metrics would have reported healthy midpoints.
Context
The repo had policy-level symmetry-breaking evidence strong enough to make separate scoring a battery rule: "左右必须分开打分 … 平均 vy 跟踪会把它掩盖". Notably, chirality broke and never recovered even though mirror augmentation (command-level mirror_prob 0.5) was on the whole time - augmentation reduced but did not prevent asymmetry, and once broken it stayed broken through subsequent rungs. PASS conditions therefore carried explicit symmetry budgets (left/right tracking gap <=10 pp), and sim's predicted asymmetry (700: right faster than left) was flagged for direct real-robot timing confirmation.
Change
Battery rule: every directional skill reports left and right (CW/CCW) as separate rows with a max-gap budget; mirror augmentation treated as mitigation, not proof of symmetry.
Outcome
The 700-vs-A800 asymmetry gap (15 pp vs 7 pp) became a first-class selection criterion; C4 product shipped with a measured 5 pp gap.
Mechanism
Averaging over mirrored conditions cancels antisymmetric error exactly where it matters; and symmetry lost during training is a lineage injury (like plasticity loss) that later rungs do not spontaneously heal, so it must be gated, not assumed.
Applies when
- evaluating turn/sidewalk/push-recovery or any mirrored skill
- relying on mirror/symmetry augmentation
- selecting between checkpoints with similar average scores
“左右必须分开打分(left/right lateral、CW/CCW turn 各自一行)—— 本仓已有 policy-level symmetry breaking 的量化证据,平均 vy 跟踪会把它掩盖。”
train/C_LADDER_RUN.md § 5. 固定验收矩阵 (左右分开打分) Tightening the bridge's rate limiter under an unchanged policy cut torque peaks 30-50% and made other things worse - the policy cannot see the limiter, keeps commanding and winds up; a deploy-side limiter is a safety net, not a cure
deploy-rate-limiter-windupA rate or torque limiter added at deployment lowers peaks but the policy still commands as if unconstrained (saturation, windup, new contacts); use it as a safety net mirrored in evaluation, and put the constraint where the policy can learn around it.
Symptom
After the violent first real-robot get-up, the cheapest candidate fix was to tighten the bridge's slew (rate) limit for the recovery policy without retraining.
Context
Probe on R3.1 in MuJoCo (5 categories x 3 seeds, mu 1.0), monkeypatching the limiter with no repository change: TIGHT = RS06 4.0 / RS02 3.0 / RS00 2.0 rad/s (about 0.08/0.06/0.04 rad per policy step) against the current vel_limit setting.
Change
The probe decided the role of the limiter rather than a deployment.
Outcome
Success 14/15 -> 12/15; get-up median 2.35 -> 3.53 s (max 9.30); torque demand peak median hip_pitch 164% -> 111%, knee 166% -> 86%; action saturation still 100%; leg-leg contact 558 -> 860 frames. The limiter was kept only as a real-robot safety net (mirrored into sim2sim evaluation); the cure moved into training - where the next lesson was that a limiter anchored on the last command is itself an integrator (slew-anchor-is-an-integrator).
Mechanism
A policy that never trained with the limiter keeps issuing the targets it learned; the limiter clips them, the target window runs ahead (windup), and the robot follows a trajectory the policy never evaluated.
Applies when
- a trained policy is too violent on hardware and a quick deploy-side fix is tempting
- adding slew, torque or velocity limits in a bridge or firmware
- evaluation and deployment use different limiter settings
“判读:**链路侧收紧立等可取地把 τ 峰值砍 30~50%,但成功率掉、饱和率仍 100%、 腿-腿接触反升** —— 策略感知不到限速器,目标窗口继续狂奔。⇒ 收紧 slew 只配当 **真机侧安全网**(必须同步进 sim2sim 口径,基础设施现成),**不配当治法; 治法必须进训练**。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §26 探针:收紧桥层 slew,r3_1 不重训直接测 Record where every failed episode ends - an end-state confusion matrix showed all failures finishing seated and overturned a "cannot roll over" diagnosis that per-category success rates hide by construction
end-state-confusion-matrixFor any multi-category acceptance, report where each failed episode ends, not only which category it started in; it costs a few lines and no extra simulation, and it separates "cannot reach the goal" from "reaches the wrong basin".
Symptom
Prone scored 0% for three generations; the working diagnosis was "prone lacks the roll-over skill", and R0.3 spent a run adding prone-to-side roll-arc start states. It bought nothing: the 45-deg roll band itself only moved from 24.2% to 26.6% after 3,000 iterations.
Context
Acceptance reported success per starting category. A final-state table (lying prone / on the side / supine / seated / standing for every failed episode) was added to accept_recovery.py at R0.3.
Change
The confusion matrix became a permanent part of the acceptance output, and the prone diagnosis was rewritten from it.
Outcome
The prone, side and supine columns were all zero - every failure ended seated - and prone had righted its torso in 159/159 episodes (tilt under 30 deg in 100%). The missing ability was standing up from one specific seated configuration, not rolling over, which redirected the next rungs to foot placement and to a configuration probe.
Mechanism
Per-category success rates collapse "reached the wrong basin" and "never reached anything" into the same zero; the end state separates them.
Applies when
- a category sits at 0% and the diagnosis rests on its label
- recovery, manipulation or navigation tasks with distinct terminal states
- an intervention aimed at the presumed cause shows no effect
“**① 末态混淆矩阵 —— 固化(已在 `accept_recovery.py`)。** 它给出的 "趴/侧躺/仰躺三列全 0、所有失败都终于坐姿"是本线最改变决策的一个事实, 而**逐类成功率按构造看不见它**。 … 成本十来行、零额外仿真。 … **② prone 病因更正(旧诊断作废)。** 旧:"缺翻身"。新:**prone 159/159 全部 把躯干翻正**”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §15 R0.3 判决 + 三件事的判断 Brief the operator on the lineage's measured zero-command and untrained-axis behavior before handing over the joystick
know-zero-command-behaviorBefore any teleop/demo, measure and write down the policy's zero-command behavior and per-axis competence, label untrained axes explicitly as not-bugs, and set the floor/procedure to accommodate the known drift.
Symptom
A teleop session was about to start on a policy that does not stand still at zero command and has never been trained on lateral commands - behaviors an unbriefed operator would report as bugs or emergencies.
Context
Three measured facts were written into the teleop instructions ("都有 实测依据, 不是猜"): (1) A/D (lateral) keys will get essentially no response - probe-measured sidewalk tracking ~3%, an untrained axis: "这正是 C4 要解决的事, 不是 bug"; (2) no keypress = cmd 0, and this lineage does not stand still at zero command - a three-generation lineage property: paces in place, drifts right ~5 cm/s, net rotation -30 deg/20 s; sim survival is 20/20 (it will not fall) but it walks away slowly, so leave floor margin especially on the right; (3) S (backward) WILL respond - probe-measured 20/20 survival, 67% tracking untrained, which is also why this root was chosen for the C ladder. Plus a keybinding dry-run while suspended before touching down.
Change
Operator briefing became part of the deployment artifact: expected response per key, expected idle behavior with magnitudes and directions, and the distinction between untrained (expected, not a bug) and abnormal.
Outcome
The session proceeded with correct interpretations available in advance; the known zero-command wander was handled by floor margin and start-with-command procedure rather than misdiagnosed on the spot.
Mechanism
A learned policy's off-nominal behaviors (idle drift, untrained axes) are lineage properties, stable and measurable in sim beforehand; operator surprise converts known properties into false incident reports and unsafe reactions. A briefing transfers the measured behavior model to the person holding the controller.
Applies when
- handing a learned policy to an operator or demo audience
- the policy idles in a non-stationary way at zero command
- some command axes are untrained in the current lineage
“A/D 基本不会有反应 —— s1e 从未训过非零 vy, 选根探针实测侧走跟踪率 ~3% … 这正是 C4 要解决的事, 不是 bug。… 不按键 = cmd 0, 而 s1e 在零指令下不站定 —— 血统属性, 三代实录: 原地踏步 + 右漂 ~5 cm/s + 净旋 −30°/20s。”
train/REAL_RUN_S2.md § 附: WSAD 遥控 上机前必须知道的三条 Order hardware runs by sim risk, gate each stage on the last, and put the fragile cell last with a spotter
risk-ordered-real-deploymentScript hardware sessions as a risk ladder: baseline first, sim-riskiest last with a spotter, suspended smoke before ground, each stage gated on the previous, environment (floor mu) recorded as a selection input - and stop at the stage that misbehaves.
Symptom
Five policy-x-gain combinations had to go on hardware in one session, with sim survival ranging from 20/20 down to 17/20 (and zero-command survival down to 2/20) - an unordered session risks breaking the robot on an avoidable run.
Context
The execution sheet fixed the order as sim-risk low to high, control baseline first (current SOTA establishes the floor reference), the fragile cell (fric-2400@kd1.0) last with a person spotting throughout. Stage gating: suspended smoke (feet off ground, 10 s each, all five pass before anything touches down) -> suspended with IMU and forward command (gait forms in the air) -> grounded runs -> speed raise only for combos that survived the previous stage -> zero-command tests only with a spotter, ordered by sim zero-cmd survival, with the 2/20 cell skipped by default. Preconditions include recording the floor material and estimating mu (if mu <~0.6, sim says pick the kd1.2 gain as main), port/CAN self-check, calibration frozen. Any stage failing stops the session at that stage: "任一段出问题就停在那一段, 不要跳到下一段".
Change
Session structured as a risk ladder with per-stage gates instead of a flat checklist; per-combo sim survival numbers written into the run table as the ordering key.
Outcome
The session design localized any failure to the cheapest stage that could reveal it, kept the robot safe for the informative fragile run, and made the control baseline available before any comparison run.
Mechanism
Hardware sessions consume a shared budget (robot integrity, battery, floor time); ordering by predicted risk means information is bought cheapest-first, and stage gates convert an expensive failure into a cheap earlier one. Baselines run first because every later reading is relative to them.
Applies when
- taking multiple policies/configs to hardware in one session
- a candidate is known-fragile in sim but must be measured
- writing a deployment runbook for a new robot
“跑序 = sim 风险从低到高, 最险的放最后 (依据 = 存活门/零指令存活) … ⑤ 是 sim 里最脆的一格 … 放最后跑, 全程留人扶, 起步即给 cmd, 零指令不做。… 任一段出问题就停在那一段, 不要跳到下一段。”
train/REAL_RUN_S2.md § 上机名单 / 全部命令 Model CAN polling skew - joint observations are 6-9 ms stale by read order
can-timing-skew-modelingIf joints are read sequentially over a shared bus, reproduce the per-group observation staleness in sim (or randomize it over the measured range) - synchronous observations are a privileged fiction.
Symptom
Policies trained with synchronous joint observations degrade on hardware where motors are polled sequentially over CAN - hip data is already 6-9 ms old by the time ankle data arrives.
Context
Menlo's core sim2real finding on a leg platform of almost identical mass to Lucen's. CAN is a sequential bus: one poll cycle reads motors in a fixed order, so the observation vector mixes timestamps. Lucen runs 6:6 motors on a dual CAN split, so the problem transfers one-to-one.
Change
Explicitly model CAN timing skew in sim: give the joint groups different observation delays matching physical read order. Menlo went further - running real firmware in the loop with a motor simulator between MuJoCo and firmware injecting 0.4-2 ms uniformly distributed delay.
Outcome
Reported by the reference team as their core sim2real enabler on a same-scale platform; recorded in Lucen's experience log as directly applicable ("这个问题一模一样").
Mechanism
A policy exploits any cross-joint temporal coherence present in training observations; when hardware breaks that coherence per bus position, the learned feedback acts on inconsistent state estimates, injecting phase error exactly at the control bandwidth.
Conflicts
Second-hand episode: outcome numbers are the reference team's report, not a Lucen-run experiment; Lucen adopted the requirement but the corpus has no Lucen A/B of skew-on vs skew-off.
Applies when
- robot polls actuators sequentially over CAN/RS485 or similar shared bus
- sim2real degradation appears as jitter or oscillation not seen in sim
- designing the observation/delay model before a training run
“电机走 CAN 是顺序轮询的,髋部电机的数据到踝部电机上报时已经陈旧了 6-9 ms,他们直接在仿真里显式建模了 CAN 时序偏斜,按读取顺序给三组关节不同的观测延迟。… 注入 0.4–2 ms 的均匀分布延迟。你们是 6:6 双 CAN 分总线,这个问题一模一样”
Experience.md § 执行器 + 时序建模 (line 6) A frame-history observation under zero DR memorizes the trainer's plant fingerprint - the estimator must see variation to learn estimation
history-obs-needs-plant-variationIf the observation carries history (stacked frames, RNN), keep at least minimal plant variation (gain/latency jitter) on from the first iteration - "nominal first, robust later" is structurally invalid for estimator-bearing contracts.
Symptom
omni_s1 (fresh 215-dim contract with a 5-frame history window, trained with DR fully off): training all green, yet the MuJoCo gate scored 0/20 on all eight doors - falls within 2 s, seven checkpoints, not one transferred.
Context
The history window exists precisely to let the actor implicitly estimate line velocity and actuator dynamics (the actor is denied base_lin_vel by observation honesty). Under a constant plant that implicit estimator has nothing to estimate - it learns the trainer's exact response fingerprint instead, and any other simulator's micro-differences are out-of-distribution: "5 帧窗按设计就是隐式估计器, plant 恒定时它学到 Isaac 精确响应的指纹". The planned "nominal-first-robust-later" staging was declared STRUCTURALLY incompatible with history observations: "估计器要见过变化才学估计, 否则学背诵" (an estimator must see variation to learn estimation, otherwise it learns recitation). Honest confound note kept: this is mixed with "zero DR does not transfer, period" - but both attributions prescribe the same fix, so no control was run.
Change
S1.1: minimum actuator jitter turned on from day one - kp/kd +/-10%, latency 0-1 frame (friction/COM/mass still nominal, no push - those stay for the S2 ladder).
Outcome
Transfer restored: survival 0/20 -> 20/20, speed 19/20, foot distance 20/20 (remaining failures moved to gait quality, a different disease); the staging doctrine was amended - history-carrying contracts never train under a frozen plant.
Mechanism
A recurrent/history channel fits whatever temporal structure minimizes loss; with a deterministic plant the cheapest structure is the plant's own impulse-response signature, yielding features that are simulator-specific rather than physics-general. Plant variation forces the channel to carry state-estimation features that transfer.
Conflicts
Attribution is explicitly confounded with the simpler "zero DR never transfers" reading ("与「零 DR 本身就不迁移」混杂 … 两种归因处方相同, 不做对照") - the source chose not to spend a control run separating them.
Applies when
- adding frame stacking or recurrence to an actor observation
- a nominal-plant policy fails a cross-simulator gate within seconds
- planning DR staging for a new contract
“frame_hist × 零 DR = plant 指纹过拟合——5 帧窗按设计就是隐式估计器, plant 恒定时它学到 Isaac 精确响应的指纹, MuJoCo 的微小差异即 OOD, 2 s 内摔, 七个 checkpoint 无一迁移。「先标称后鲁棒」的分段与历史观测结构性冲突:估计器要见过变化才学估计,否则学背诵。”
train/OMNI_V0_SPEC.md § 3. S1.1 修订记录 ① The latency DR range must cover the measured deployment pipeline - 0-20 ms could not even reach the real 1-2 control steps
latency-dr-covers-measured-pipelineMeasure end-to-end action latency in control steps on your own stack (including cross-process queue boundaries), set the DR range to cover it with margin, and never import a delay count without its control frequency.
Symptom
Action latency was randomized over 0-20 ms (0-1 control step at 50 Hz), but the measured deployment path is 1-2 steps: the deploy process writes the target, an independently running BusWorker picks it up on its NEXT cycle, plus CAN round-trip - the training range could not cover the robot's actual latency at all.
Context
Fix: widen action_latency_s to 0-0.06 (0-3 steps). The external reference's "uniform 6 steps" was explicitly NOT copied - that number depends on his unknown control frequency; locally, a sweep at 0/1/2/3 steps showed walk_v5 survives all with insensitive metrics, so 6 steps "在我们这里没有依据" (has no local basis). The range was set from the measured pipeline with margin, not from a foreign constant.
Change
action_latency_s (0, 0.02) -> (0, 0.06), justified by pipeline analysis (writer/worker cycle boundary + bus time) and bounded by the local latency sweep.
Outcome
The DR band now brackets the true deployment latency; the policy trains against the delay it will actually face instead of a fictional sub-step world.
Mechanism
Latency DR only immunizes against delays inside its support; a range below the physical pipeline guarantees an untrained distribution shift at deployment. The correct range comes from tracing the pipeline's worst case (queueing boundaries + transport), and foreign step-counts are meaningless without the control rate they were measured at.
Applies when
- setting or auditing action-delay randomization
- deployment uses a separate bus/worker process from the policy loop
- importing delay-modeling numbers from other projects
“现行 0~20 ms = 0~1 个 50Hz 控制步, 而实测部署链路是 1~2 步(deploy 写 STATE.target 后, 独立跑的 BusWorker 下一轮才取走下发, 再加 CAN 往返)——现在的区间覆盖不到真机的实际延迟。… 不照抄参考来源的"统一 6 步": 那取决于他的控制频率(未知), 而我们扫过 0/1/2/3 步 … 6 步在我们这里没有依据。”
train/WALK_V7_SPEC.md § ⑤ action_latency_s 0~0.02 → 0~0.06 Privileged signals (true velocity, foot force, foot height) go to the critic only
observation-honesty-critic-onlyTreat the actor observation vector as a hardware contract: every element must exist on the real robot with realistic noise; privileged simulator truths belong in the critic only.
Symptom
Policies trained on ground-truth base linear velocity work in sim and fail on hardware, where only a drifting IMU and encoders exist - the policy has learned to depend on a signal that does not survive deployment.
Context
Many open-source locomotion stacks feed simulator ground-truth linear velocity to the actor. The reference team refused: the real robot has no ground-truth velocity. Asymmetric actor-critic keeps the training benefit of privileged information without deploying the dependency.
Change
Route ground-truth velocity, foot contact forces, and foot heights to the critic only; the actor observes exclusively signals that exist on hardware (IMU-derived quantities, encoders, commands, previous actions).
Outcome
Recorded as adopted doctrine in Lucen's experience log; the trained actor's input contract matches what the real robot can actually produce.
Mechanism
The critic is discarded at deployment, so it may consume any privileged state to reduce value-estimation variance; the actor's observation set is a deployment contract - anything in it that hardware cannot supply (or supplies with different noise/drift) becomes a train/deploy distribution shift the policy was never trained to handle.
Applies when
- designing actor/critic observation spaces
- reviewing a config where the actor sees base_lin_vel or contact forces
- sim policy is strong but real robot drifts, oscillates, or falls without obvious actuator cause
“很多开源代码库把真值线速度喂给策略,Asimov 团队没有,因为真机上没有真值速度,只有会漂的 IMU 和编码器;用完美速度训练出来的策略会依赖它,然后在硬件上失效。真值速度、足底力、足高统统只给 critic”
Experience.md § 观测空间的诚实性 (line 7) A nonzero response with the same sign for + and - commands is bias, not ability
same-sign-response-is-yaw-biasBefore crediting any directional skill, test both command signs: response must flip sign with the command; a same-signed pair is a bias to subtract, not an ability to report.
Symptom
Root-selection probe showed nonzero wz "tracking percentages" on turn commands, tempting the read that candidates could partially turn.
Context
During C-ladder root selection, s1e-500's measured yaw rate was +0.084 rad/s for cmd +0.3 and +0.093 rad/s for cmd -0.3 - same sign both ways. The same check on the C2 baseline gave wz+0.20 -> -0.13 and wz-0.20 -> +0.12 (again same sign), while the alternative root s2e_pd-1400 gave +0.16 / -0.16 - opposite signs, i.e. a genuine 16% command response.
Change
Reading corrected and written into the execution sheet: percentages on directional commands are meaningless unless the +cmd and -cmd responses have opposite signs; all three candidates were re-classified as "cannot turn, cannot sidewalk - C2/C3/C4 learn from zero". Acceptance criteria thereafter required "tracking >=50% AND left/right opposite-signed".
Outcome
Prevented crediting turn/sidewalk ability that did not exist; the antisymmetry clause became a standing part of every turn and sidewalk PASS condition (C2, C4, C4-redo levels all carry "且左右反号").
Mechanism
A constant yaw (or lateral) bias projects onto any command's sign convention and shows up as fake fractional tracking; only sign-antisymmetry under command reversal distinguishes a feedback response to the command from an open-loop offset.
Applies when
- evaluating turn/sidewalk/any signed-command tracking percentages
- a candidate shows partial tracking on an axis it was never trained on
- writing PASS criteria for a new directional skill
“C2/C3 那些非零的 wz 百分比不是转向能力 —— 转向+ 与 转向− 的实测同号(s1e:cmd +0.3 → +0.084,cmd −0.3 → +0.093 rad/s),那是恒定偏航偏置。… 三个候选都不会转、都不会侧走。”
train/C_LADDER_RUN.md § 0. 读数纠正(重要,别引错) A stand gate judged by survival passes a robot that wanders a meter - judge posture instead
stand-gate-posture-not-survivalFor every gate, ask what behavior the metric is a proxy for and validate its ordering against real observations; replace metrics whose ordering disagrees with reality, and demote them explicitly rather than silently.
Symptom
Real robot "standing" drifted 0.5-1.4 m across the floor while the sim stand gate scored a clean 20/20 - because the gate's metric was episode survival, which wandering does not violate.
Context
C2's stand condition was originally written as "survival regression <=2/20". A real-robot counter-example on 2026-08-08 forced the re-judgment: wandering robots survive. Cross-checking candidate sim metrics against real-robot feel showed max-tilt median ordering agreed with hands-on ranking, while displacement ordering was actually OPPOSITE to real impressions - so displacement was demoted to a reference quantity, not a gate.
Change
Stand PASS criterion rewritten from survival to posture: "stand tilt max median <= root baseline +1.5 deg"; displacement kept only as reference. Applied to all subsequent rungs (C4 and redo levels inherit it).
Outcome
Later rungs gated stand on tilt (e.g. C4 product: 7.7 deg vs parent 7.1 deg, +0.6 deg PASS); the wandering failure mode became visible to the battery instead of hidden by survival.
Mechanism
A gate metric is a proxy for an intended behavior; survival is a proxy for "did not fall", not "stood still". Metric choice must be validated against ground truth (real-robot feel/measurement), and a proxy whose ordering disagrees with reality on real data is worse than no metric - it steers selection backwards.
Applies when
- writing PASS conditions for stand/idle/hold behaviors
- a gate passes policies that visibly misbehave on hardware
- choosing between candidate metrics for an acceptance battery
“stand 必须用位姿判,不能用存活判(2026-08-08 真机反证改判):站着乱走 0.5~1.4 m 时存活照样 20/20 —— C2 的 stand 条件原写「存活退化 ≤2/20」,选错了指标。改为: stand 倾角 max 中位 ≤ 根基线 +1.5°(倾角与真机手感排序一致;位移排序与真机相反,降为参考量)”
train/C_LADDER_RUN.md § 3b. PASS 条件 ⚠️ stand 必须用位姿判