Training Coach
Doctrine
A report may cite any of these as doctrine-N.
doctrine-1Contract freeze and fingerprint disciplineThe policy I/O contract (observation layout, scales, history semantics, action pipeline) is frozen and fingerprinted; every exported policy is stamped and verified; contract changes ship as new versioned profiles that leave old artifacts bit-identical, and old policies run forever under their era's pinned profile.
Case. The 215-dim omni contract was frozen with a three-machine digest; the one contract-level extension (lateral feed-forward) went in as a new `omni_ff` profile with the old profile provably untouched, and the contract checker caught two real wiring bugs before any training (`contract-freeze-and-checker`). A silently changed gait-clock default would have fed old policies a 25% slower clock - closed by pinned legacy profiles (`legacy-profile-pinning`). A stale derived USD forked plant mass 2.2% until an automated source-vs-derived instrument gated it (`derived-asset-staleness-check`). A gain profile is part of the closed loop a policy was trained in and belongs in its stamp; the recovery line's anchored authority was left out of its manifest and recorded as the gap not to repeat (`gain-profile-belongs-in-the-stamp`), and a second policy behind a deploy-side switch made the handoff state itself a contract (`recovery-two-policies-and-a-state-machine`, `walk-recovery-fsm-handoff`).
Coach application. On any proposal touching obs/action semantics, defaults, or derived assets: demand the version/profile plan, the fingerprint update, and the checker extension in the same change; flag any old artifact that would run under new defaults.
doctrine-2Attribution by resolved training params - never eval-override knobsCapability differences between lineages are explained only by digging each lineage's *resolved* training configuration and eliminating columns; evaluation-side override knobs (kd-scale, power-scale, cycle-time) act on the plant for *every* policy and may serve as deployment mitigations but never as explanations.
Case. Low-friction robustness across 8 lineages x 3840 cells was traced to kd DR *bandwidth* - every lineage had ground friction pinned to (1.0,1.0), so "trained friction" could not be the axis; the parameter axis and the plant axis were explicitly separated after the first attribution conflated them (`kd-bandwidth-mu-law-attribution`). "Weak turning" on hardware was a power-scale plant effect, not a training gap (`deploy-knob-attribution-before-retraining`); slowing the deploy clock was out-of-distribution, not a feature (`cycle-time-override-is-ood`). The ground truth for what a run trained under is the logged per-run config, not the source tree (`resolved-config-is-source-of-truth`).
Coach application. Whenever asked "why is lineage A better", require the resolved-param table first; kill zero-variance columns; refuse explanations phrased in eval-knob terms; when a knob helps, label it deployment mitigation.
doctrine-3PASS gates become constraints; FAIL gates become objectivesOnce a skill passes its gate, that gate converts into a standing regression constraint (budget <= 2/20 against the parent baseline) for all later training; gates currently failing are the only legitimate objectives of the next rung.
Case. The C ladder ran one frozen 13-cell x 20-seed matrix at every rung with promotion = "new skill PASS and old skills within regression budget"; C1 was stopped and re-rooted precisely because it trained away the root's backward PASS (`fixed-acceptance-matrix-per-rung`, `preregistered-stop-criteria-per-rung`). The C4 product shipped only at 260/260 cells with zero regression.
Coach application. Keep the ledger: every PASS adds a constraint row; propose rungs only against FAIL rows; treat any constraint violation as stop-and-attribute, never "the next rung might win it back".
doctrine-4One variable per ladder rung - counted against what the checkpoint sawA rung changes one variable, where "one" is counted against the checkpoint's actual training state, not against the current config's diff; batching is allowed only when each change owns a disjoint symptom space with a pre-registered ablation order.
Case. Two rungs failed identically because resuming s1e-500 under the evolved config silently added four plant variables the checkpoint had never seen ("单变量纪律不只看「我改了什么」,还要看「checkpoint 见过什么」" - `resume-state-dr-audit`). v8 legally batched four orthogonal fixes with a written ablation order (`orthogonal-batch-with-ablation-order`); v9 spent one run completing a 2x2 factorial so either outcome convicted a factor (`fill-the-missing-factorial-cell`); v10b's three-way ablation wrongfully convicted the clock and had to be retried fairly.
Coach application. Before any resume: diff cfg against the checkpoint's logged training state. Before any batch: require the symptom-ownership map and ablation order in writing.
doctrine-5Pre-register risks, readings, and stop criteria before the ladderBefore a ladder or risky rung, write down the known risks, the interpretation of every plausible outcome, and hit-any-one stop criteria - frozen before training, tightened when priors say results should come fast.
Case. The C ladder opened with three numbered risks including the exact falsification condition for its own root choice; A/B arms carried "预注册读法(事后不改)" tables; a level expected to fail was run anyway for its pre-registered diagnostic value (`preregister-risks-and-fork-readings`). Stop criteria caught C4-redo rungs at +200 instead of full caps (`preregistered-stop-criteria-per-rung`); hardware sessions pre-registered per-config expected signatures and the disagreement rule "不改结论改账" (`preregistered-real-expectations`, `feasibility-accounts-lock-design-point`).
Coach application. Refuse to open a rung without the written risk/reading/ stop block; after results, read conclusions off the pre-registered table and flag any post-hoc reinterpretation.
doctrine-6Plant parameters are measured, never inventedEvery plant number carries measurement provenance: armature = N^2 x rotor inertia from no-load tests, friction split by rig and by API column, torque limits shaped by per-joint gait peaks, latency traced through the real pipeline, masses weighed - and DR bands are additive around the measured nominal, sized to the measured dispersion.
Case. Guessed friction was 2.5x low and guessed damping 5x high (`friction-measured-not-guessed`); armature had been 0 with a 9:1 gearbox (81x reflected inertia, `armature-n2-rotor-inertia`); a uniform torque derating was "the wrong shape" vs measured peaks (`torque-limit-shape-by-measured-peaks`); the delay implementation itself was a wrong plant for a whole lineage (`latency-lerp-reverse-extrapolation`); the run design point was locked by three accounts including the tau_limit/kd speed ceiling (`feasibility-accounts-lock-design-point`); identified friction had to land in the right simulator API columns to act at all (`sim-api-friction-columns`). The recovery and one-leg lines opened with the same kind of accounts before any reward existed - a connected static path and the torque along it for an armless get-up, and the gains single support needs to be holdable at all (`get-up-feasibility-accounts-before-training`, `single-support-gain-authority-probe`).
Coach application. For any plant value in a config review, ask "measured how?"; reject absolute ranges with no nominal; check API column mapping and derived-asset regeneration whenever measured values land.
doctrine-7Sim2sim gate before sim2real - under deployment conditionsEvery checkpoint passes a second, independently built simulator before hardware, and both the gate and the smoke loop run under the measured deployment conditions (real pipeline delay, honest contact parameters, the deployment gain/power profile).
Case. The standing order "先sim2sim 再sim2real" (`sim2sim-gate-before-sim2real`); acceptance flipped to match hardware only under measured condim/torsional friction (`eval-plant-honesty-contact-params`); gates moved permanently to `--delay 2` after the kicking incident (`pipeline-latency-is-plant-not-dr`); and the harness itself must be audited - a frame-convention bug in the cross-sim evaluator invalidated a whole line of verdicts (`body-frame-velocity-api-audit`). The recovery line's second simulator caught a torque penalty paid for by bracing the legs together (`torque-penalty-bought-by-leg-bracing`), and a 1.8x torque disagreement between the two plants stayed binding because its one surviving explanation was never tested (`torque-disagreement-between-simulators-unresolved`).
Coach application. Block any hardware request lacking a second-sim PASS at deployment conditions; when sim2sim and training-side metrics disagree, treat the evaluator as a suspect too.
doctrine-8Observation honesty - the actor's inputs are a hardware contractThe actor observes only signals the real robot produces with realistic noise; privileged truths go to the critic; history windows are estimators and must train under plant variation; rewards on quantities the actor cannot observe buy only average suppression, never closed-loop correction.
Case. Ground-truth velocity/forces went critic-only (`observation-honesty-critic-only`); frame_hist under zero DR memorized the trainer's plant fingerprint - 0/20 transfer (`history-obs-needs-plant-variation`); world-frame yaw rewards could not teach pull-back because heading is unobservable to the actor - correction was routed to the deploy outer loop instead of breaking the contract (`reward-observability-limit`, `deploy-heading-loop-and-align-training`).
Coach application. Audit every actor-obs element for hardware existence; require minimal plant jitter whenever history/recurrence exists; for each reward, ask "can the actor see this error?" and route correction tasks to outer loops.
doctrine-9Reward economics are audited in realized currencyReward design decisions are made on realized per-step magnitudes under the actual policy and command distribution: price the do-nothing optimum before adding a mode, compare achieved values to the computed ignore-floor, calibrate thresholds between measured healthy and sick distributions, and ship every new penalty with a withdrawal clause.
Case. feet_air_time at weight 2.0 realized 0.038 vs tracking 1.2 - drag was rational (`realized-contribution-audit`); ignoring a vy command cost 28-180x less than ignoring vx until a gated tracking term was added (`reward-cost-of-ignoring-audit`, `gate-new-reward-terms-by-command`); achieved-vs-floor separated "never learned" from "priced out" (`ignore-floor-diagnosis`); the foot-distance wall was placed between measured healthy (0.6% tax) and sick (55%) policies (`calibrate-threshold-between-healthy-and-sick`); the landing penalty carried a pre-registered stand-down condition and actually stood down (`calibration-threshold-with-withdrawal-clause`); two clearance terms were inert until zero-points and gate occupancy were checked (`inert-reward-term-audit`). A get-up policy sat because three gated terms paid the seated pose 84% of the return and the one term that could tell sitting from standing was an exp kernel reading 4.6e-5 at the real error (`seated-basin-dead-exp-kernel`); a torque-tail term was weighted by its measured steady value beside a peer term after the estimate proved 12x off (`tail-torque-needs-hinge-on-computed-demand`).
Coach application. Never discuss weights in the abstract: demand the realized-contribution table, the ignore-floor number, and the healthy-pay calibration before any reward edit is approved.
doctrine-10The zero-cost option must be the desired behaviorFor every penalty, name what the zero-cost option is; penalize failure events (slip, saturation excess, contact in flight windows), never the motion or joints that healthy behavior uses; make degenerate strategies fatal via termination where penalties cannot price them out.
Case. Joint-usage penalties for drift taxed a 1.4%-of-momentum channel 2.7/step and collapsed training; the slip penalty costs a non-slipping gait exactly zero (`penalize-the-slip-not-the-joint`). A frozen-at-clamp joint pays zero action-rate forever - only a pre-clip saturation penalty flips the cheat economics (`saturation-cheating-zero-rate-cost`). Ungated phase shaping made standing 42x more expensive than stepping and cooked the hip motors (`moving-gate-42x-stand-tax`); crouch-shuffling lived until a height termination deleted it (`termination-closes-degenerate-basin`). A gated penalty is an exit: the policy parked just outside an uprightness gate, then just under a height gate, to stop paying a stance tax, and only a positive band plus an always-on guard closed both (`penalty-gate-is-an-escape-hatch`); a soft-limit penalty that charged the standing pose itself bought a 4.1 deg lean (`soft-limit-penalty-charges-nominal-pose`); an unpriced foot attitude was spent on edge-standing (`unpriced-foot-attitude-is-a-free-variable`); and the one-leg line listed its cheapest cheats before training and still met one through a zero-gradient band (`enumerate-cheapest-cheats-before-training`, `binary-band-reward-fake-touchdown`).
Coach application. Run the "零代价的选项是什么" audit on every proposed term; convert motion taxes into event-conditional penalties; check the termination set against each known degenerate strategy.
doctrine-11Measurement discipline: independent referees, signs, distributionsA disputed measurement is adjudicated only by an independent algorithm from raw state; directional ability requires sign-antisymmetry under command reversal; bimodal metrics are reported as mode shares (never medians, never 3 seeds); ratios are not comparable when totals change; reward values compare only within one command distribution; single chaotic events never cross machines.
Case. The triple reversal - a good metric was "refuted" by a sibling metric that shared the disease (`independent-referee-for-metric-disputes`, `body-frame-velocity-api-audit`); same-signed +/- responses were bias, not turning (`same-sign-response-is-yaw-bias`); the swing median sat in a bimodal gap (`median-hides-bimodal-distribution`); "v6 is jitterier" died on absolute energies (`ratio-metrics-need-absolute-check`); yaw gain measured 15x wrong in an oscillating frame (`heading-integral-not-body-rate`); a 44% improvement evaporated under same-distribution comparison (`same-distribution-reward-comparison`); drift direction was a limit cycle (`multiseed-sign-test-for-drift`); a cross-machine push cliff was chaos (`single-impulse-recovery-is-chaotic`).
Coach application. Before accepting any surprising number: ask for the independent recomputation, the sign pair, the distribution shape, and the comparison conditions. Retract in writing when a metric falls.
doctrine-12The deployment pipeline is plantIrreducible pipeline properties - action latency, rate limits, power/torque scaling, teleop command mappings - are part of the nominal plant, modeled from day one and reproduced in every gate; deploy-side scalings are crutches that flag unmodeled plant, and they cannot be algebraically folded into training constants.
Case. Right-leg kicking was over-trained-delay x loop gain; power 0.8 was a gain-reduction crutch that retired when the delay was modeled (`pipeline-latency-is-plant-not-dr`); power derating damages non-forward axes first (`power-scale-hurts-nonforward-axes`); training at 0.4 scale as the "twin" of deploying 0.5 x 0.8 collapsed 0/20 (`deploy-scaling-not-training-equivalent`); one shared teleop speed sent an out-of-band lateral command and the robot clipped its own foot (`teleop-command-band-per-axis`); the latency DR range had not even covered the measured pipeline (`latency-dr-covers-measured-pipeline`). A rate limiter added at deployment only clipped a policy that kept commanding (`deploy-rate-limiter-windup`); moved into training and anchored on the last command it became an integrator in the balance loop (`slew-anchor-is-an-integrator`); anchored on the measured angle it bounded torque and kept the bandwidth (`beta-anchored-action-target`). The walking lines' safe setting, power-scale 0.8, cut the ends of the recovery policy's full-range travel and left its spikes alone; a gain inside the trained band did the job (`power-derating-cuts-full-range-contract`).
Coach application. Demand the measured pipeline latency/limits in the plant model and in gate conditions; treat every deploy-side derating as a question ("what is this compensating?"); block per-axis command sources that exceed training bands.
doctrine-13DR budget is finite; its distribution is the measured supportRobustness is a conserved budget: disturbance training on an already-hardened lineage borrows from existing margins; DR ranges span the measured deployment support - no fictitious tails (they buy degenerate gaits), no single constants (they allow thin-margin specialization); harden the plant only after the task distribution is final.
Case. The same push dose helped a narrow lineage and damaged a balanced one - budget conservation (`push-dr-conditional-budget-conservation`); wide latency tails bought drag-glide, constant values shipped 60% thinner tilt margins - the answer is a narrow band on the measured support (`dr-tail-plant-continuation`, `constant-value-dr-overfits-margin`); task-first ordering because hardening a soon-to-change task wastes budget (`task-shaping-before-plant-hardening`); COM randomization used deliberately as a behavior-shaping tool, and rolled back on symptom per its own contract (`com-randomization-forces-leg-spread`, `com-dr-rollback-on-symptom`). DR that is switched on can still be thin: the run policy fell in the frontal plane its gain-and-latency randomization never touched (`thin-dr-judged-by-channel-coverage`), and a friction priority settled under one action contract had to be re-measured under the next (`friction-priority-re-measured-after-plant-change`).
Coach application. Before any DR rung: check the untrained policy against the spec, the lineage's current DR load, and the measured real-world range; after it: audit retained margins, not just the new tolerance.
doctrine-14Gates measure what hardware feels: posture, margins, stripped assistsAcceptance batteries carry posture-class rows (tilt max median, per-joint L/R asymmetry, temperature) beside task rows, graded margin columns beside binary gates, chirality scored per side, at least one condition that removes the environment's free stabilization, and validated predictive scalars promoted into the gate.
Case. Three same-shaped judging errors - survival, displacement, wz-difference - all missed what the operator felt; posture metrics had the predictive power (`task-metrics-vs-posture-metrics`, `stand-gate-posture-not-survival`); binary survival saturated and hid a 60% margin gap (`constant-value-dr-overfits-margin`); v5 passed everything on the ground and failed suspended (`suspension-probe-removes-free-stabilizer`); the hip_roll (l+r) scalar predicted real drift direction and ordering and entered the battery (`hip-roll-sum-predicts-lateral-drift`); averages hide chirality (`chirality-scored-separately`); gait-quality gates are judged at speeds that demand a gait (`low-speed-commands-reward-dragging`). The recovery line added the rest of the kit: where failed episodes end, not only where they started (`end-state-confusion-matrix`); a frozen acceptance distribution with a pinned seed (`frozen-acceptance-distribution-and-pinned-seed`); video of the metric rollout itself (`video-as-acceptance-record`); and the admission that a 10 s episode cannot see a stance that fails after a minute (`episode-length-bounds-what-a-gate-sees`). The one-leg line removed a foot-spacing wall that no gate measured, and the feet met on hardware (`removed-wall-returns-on-hardware`).
Coach application. Review every battery for posture rows, margin columns, per-side scoring, and an assist-stripped condition; when operator feel and gates disagree, suspect the metric class first.
doctrine-15Fork and root selection: recoverability, maturity, frozen rewardsChoose fork roots by which candidate's deficits the coming training can pay back (precision is recoverable; lost plasticity, symmetry, and margins are not); prefer mature checkpoints as roots even when younger ones score better as products; never fine-tune through a reward change - continuation is legal only with the reward frozen and plant/DR widening one rung at a time.
Case. s1e-500 beat higher-precision candidates because its exclusive strengths were unrecoverable (`fork-root-recoverable-shortfall`); the b300 arm proved maturity is capital against adaptation shock (`root-maturity-vs-product-quality`); the B-arm scatter/half-recover/collapse signature falsified reward-change fine-tuning and drew the legal boundary for S2 continuation (`fine-tune-reward-change-falsified`).
Coach application. For root debates, build the exclusive-strengths table and ask "which side can be trained back?"; require dual-arm evidence for maturity claims; classify any proposed continuation as reward-frozen or not before approving.
doctrine-16Curricula: verified engagement, lineage counters, disease-phase gatingAutomatic curricula must prove they engage (a saturated ratchet is constant DR wearing a curriculum's name); every ramp counts lineage-cumulative progress, not per-process steps; penalties aimed at late-stage pathologies ramp in after exploration noise decays; difficulty rises on measured per-stratum success, never on schedule.
Case. The s1f ratchet capped at iter 248 and never engaged (`auto-curriculum-engagement-check`); the saturation ramp re-fired at +600 after every resume and no shipped product ever saw the penalty (`curriculum-counter-lineage-steps`); the same penalty worked once gated to the disease phase and became an untouchable mechanism (`gate-penalties-to-the-disease-phase`); record-high aggregate reward hid a fully-failing delay stratum (`aggregate-metrics-mask-subgroup-failure`); bucket share is not a gradient lever (`bucket-share-is-not-a-gradient-lever`). An assist curriculum keyed to a pooled success share was withdrawn on the strength of the categories that already worked (`curriculum-criterion-conditioned-on-lagging-category`); a pace set by per-step income moved only when that income was time-gated (`per-step-income-drives-speed-time-gate`), and the same gate had to be retired in a lineage without the disease (`time-gate-vs-wide-stance-retire-the-fix`).
Coach application. Ask every curriculum three questions: does it engage (show the internal state)? what does it count (process or lineage)? when is it present (against the pathology's phase)? Check where shipped checkpoints sit relative to every ramp.
doctrine-17Probe before training: feasibility first, hypotheses in tablesAfter two failed training attempts at a skill, stop training: demonstrate the behavior open-loop, enumerate hypotheses in a written table audited against actual configs cheapest-first, race one probe per side of the sim2real boundary for hardware-only pathologies, and use suspended tests to acquit or convict actuators before blaming authority.
Case. "在黑暗里试钥匙" - four sidewalk rungs failed until an open-loop probe separated exploration/waveform/authority in one experiment (`open-loop-probe-before-reward-tuning`); the foot-drag mystery fell to a seven-hypothesis config audit (`hypothesis-table-code-audit`); the period-doubling was resolved by racing a reward-side and a plant-side evidence line - and both paid off, one per sub-case (`period-doubling-evidence-race`); the suspended test acquitted the roll actuator in one measurement (`suspended-test-isolates-actuator-authority`). A read-only configuration probe told a wall from a slope in the recovery line's seated basin (`configuration-probe-wall-not-slope`), and the fix it pointed to - where the feet are - took prone from 0/159 to 158/159 (`prone-dead-end-is-foot-placement`); a knob that did not move its variable was recorded as no test of the idea (`dof-vel-penalty-is-not-a-pacing-knob`).
Coach application. When a skill resists training, prescribe the probe before any further reward edits; require verified target trajectories before imitation terms; keep a falsified-fixes list so closed roads stay closed (`amplitude-cut-falsified-yaw-fix`).
doctrine-18External advice is recomputed locally; values transfer as ratiosEvery external suggestion is classified adopt / already-have / modify / trap by recomputing its claim on the local reward table and probe data; numeric values transfer only as dimensionless ratios (to tracking weight, leg length, sqrt(gL), control rate); citations are verified to exist.
Case. "Start vy very small" would have destroyed sidewalk learning on this reward table - the gradient scales quadratically (`external-advice-audit-against-own-arithmetic`); swing-height targets and weights transferred correctly only through leg-length and tracking-ratio scaling (`transfer-ratios-not-absolutes`); the "6-step delay" was refused for lacking a control rate (`latency-dr-covers-measured-pipeline`); a borrowed reference's structure was FK-verified and its amplitude re-derived from the division of labor (`reference-structure-fk-amplitude-division`); retrieval agents fabricated verbatim arXiv quotes - only source-verifiable material was used; and one dismissed suggestion later proved right for a different mechanism, and was credited (`cycle-average-tracking-for-gait-quantities`). An advisor's staged state machine turned out to exist in none of the three papers it cited, and reading them changed the plan (`advisor-paraphrase-vs-paper`).
Coach application. Intercept every "paper X does Y" with the local recomputation; convert absolutes to ratios before comparison; verify quotes; revisit dismissed advice when new mechanisms appear.
doctrine-19Hardware sessions are scripted experiments, not tuning sessionsReal-robot time executes a pre-registered matrix: risk-ordered (baseline first, fragile last with a spotter), stage-gated (suspended smoke before ground), A/B sessions bracketed by a repeated reference run, operators briefed on measured zero-command and untrained-axis behavior, chirality-aware disturbance protocols, no field tuning - the only legal field changes are scripted, single-variable, and self-reversing.
Case. The S2 acceptance sheet (`risk-ordered-real-deployment`, `battery-bracketed-real-ab`, `know-zero-command-behavior`, `push-test-chirality-protocol`, `no-field-tuning-protocol`); the RAM-only torque experiment with automatic power-cycle rollback (`reversible-single-variable-field-experiments`); and the sim-veto rule - even sim's condemnations get one safeguarded hardware check when they judge the purpose-built configuration (`sim-veto-needs-real-confirmation`). The recovery line's first real run went ahead with its preconditions unmet and was stopped as dangerous (`first-real-get-up-violent-stage-one-policy`); after it: a staged hang, mat and floor protocol (`staged-hang-mat-floor-for-get-up`), a fixed power-cycle pre-flight and two-machine discipline (`power-cycle-preflight`, `two-machine-config-discipline`), a fall guard replaced rather than switched off (`fall-guard-becomes-a-state`), and logs that are part of the run (`hardware-log-is-the-attribution-input`).
Coach application. Turn every hardware request into a runbook with order, gates, brackets, briefing, and anomaly plays; refuse improvised parameter changes on the floor.
doctrine-20Close questions in writing; restart when the debt is structuralAudited questions get frozen verdicts with citable wording and an explicit reopening bar; hardware verdicts are dated by deployment-stack and calibration state and expire when those change; and when successive rungs shuffle symptoms without net progress, freeze the lineage as regression baselines, pay the structural debts, and retrain minimal - carrying laws and instruments, not weights.
Case. The chirality and COM questions were closed with frozen wording and "no reopening without new hard evidence" (`frozen-verdicts-semantic-boundaries`); v5/v6's condemnations expired with the deploy stack (`stale-verdicts-under-old-stack`); a 2-degree calibration fix moved the whole runnable envelope (`zero-offset-calibration-shifts-envelope`); plant upgrades are era boundaries with paired re-baselining (`plant-swap-invariants-vs-shifts`); and the 2026-08-05 reset froze v5-v11, fixed the latency FIFO / manifest / sampling / reward-table debts, and restarted - producing the lineage that reached hardware SOTA (`freeze-lineage-fix-structure-restart`, `minimal-reward-table-with-provenance`). The recovery line's real-robot verdicts ended up in three places that disagree, one of them an undated note in a command file (`write-hardware-verdicts-back`).
Coach application. Maintain the closed-questions ledger and quote it when symptoms recur; stamp verdicts with stack/calibration versions; when a team is three rungs into symptom-shuffling, raise the restart question explicitly with the freeze-fix-restart pattern.
doctrine-21Name the quantity in the space it lives inA goal, reward term or acceptance criterion about the feet, the base or the contact state is computed from the quantity itself - world poses, forces, per-category outcomes - never through a joint-angle, single-signal or pooled stand-in that assumes everything else sits at nominal; and every detector is validated on a behaviour known not to contain the event before it becomes a gate.
Case. The recovery line was caught three times: |ankle roll| as "flat feet" sold stance width and the real robot slid into the splits, a hip-roll criterion was confounded by 50 deg of yaw, and the joint table said 0.271 m where the feet were 0.159 m apart; task-space terms produced the first flat, wide stance (`joint-space-proxy-for-task-space-quantity`). Flight detection lied in both directions across two lines - foot height flagged 40% false flight on a walking gait, contact force alone flagged slip chatter as hops (`contact-detector-single-signal-lies`). A pooled height average described a robot that did not exist - six in ten standing, four in ten sitting (`zero-partial-credit-is-not-an-iteration-problem`) - and the walking line had learned the same lesson on yaw rate (`heading-integral-not-body-rate`).
Coach application. For every reward term and gate row, ask what physical quantity it stands for and whether it is measured directly; flag joint-space or single-signal stand-ins for task-space goals, ask for a detector validated on a negative control, and split pooled metrics by category before reading them.
doctrine-22Continuation needs a live gradient; a release is chosen by a scanContinue a converged policy only on a change that creates a live gradient, on a short budget, with every checkpoint scanned on the transfer axis; choose a release by running the full battery over a band of checkpoints and stop on signals, never by taking the last one; and when edits to the terminal phase cannot move a behaviour, roll back and retrain with the constraint present from the start, keeping the order in which the lineage acquired its mechanisms as explicit curriculum phases.
Case. A continuation with no new gradient drifted MuJoCo transfer from 100/98% to 80/28% while every Isaac gate stayed perfect, and a live-gradient continuation at the same depth kept it (`converged-continuation-is-poison`). One-leg checkpoints 100 iterations apart failed 1 and 38 of 40 cells, and late ones degraded (`checkpoint-choice-is-a-full-gate-scan`). Four in-lineage stance fixes failed because the stance was the end of the get-up path, and from scratch it grew right (`stance-decided-by-get-up-path`); fixes stacked on degraded states were rolled back by the user (`stop-stacking-roll-back-and-audit`); and the lineage's final recipe, trained from scratch in one run, sat at 0% because the order of its curriculum was part of the product (`curriculum-history-is-part-of-the-product`). The omni line's short adaptation budgets and mature roots are the same law seen from the other side (`continuation-budget-not-from-zero`, `root-maturity-vs-product-quality`).
Coach application. Before approving a continuation, ask for the new gradient, the budget and the transfer axis in the scan; before approving a release, ask for the scan; after three rungs without progress on the target, propose rolling back to the last good checkpoint and a from-scratch phase plan instead of a fourth patch.
Experience cards
132 cards matching “thin-dr-judged-by-channel-coverage”.
Changing the gait clock silently flipped a hardwired threshold's meaning - write derived constants as expressions
derived-constants-must-track-their-baseBefore changing any base parameter (clock, control rate, scale), enumerate every constant derived from it and every constant that must NOT change; convert derived literals into expressions of the base so the next change cannot silently flip a term's meaning.
Symptom
Slowing the clock 0.40 -> 0.50 s would have silently inverted the feet_air_time threshold's semantics: the 0.25 s threshold was hardwired, so at ct 0.40 the swing window (~0.20 s) sat below it (constant pressure to lengthen strides), while at ct 0.50 the window (~0.25 s) equals it - the term's meaning flips from "push longer" to "neutral" with no code error anywhere.
Context
The clock change audit walked every dependent quantity: most followed automatically (joint_pos_ref / clearance / contact_number cycle_time params, gait_phase observation, deploy/sim2sim/policy_io, export) - wiring confirmed, zero hand edits; the air_time threshold was the one hardwired constant, fixed by preserving the RATIO: 0.25 -> 0.3125 = 0.625 x ct, with the recommendation to commit it as the expression 0.625*ct "一劳永逸" (solved once and forever). The same audit also listed what must NOT follow the clock (50 Hz control rate, physics dt/decimation, 47-dim contract, action_latency absolute seconds, PD/torque limits) - the change's blast radius stated in both directions.
Change
feet_air_time threshold re-expressed as a fraction of cycle_time; auto-following vs must-not-change lists written into the spec for the clock migration.
Outcome
The clock migration (v10, repeated in v11) carried no silent semantic flips; the expression form removed the trap for every future clock change.
Mechanism
Constants derived from a base parameter encode a ratio at their birth; storing the evaluated number severs the dependency, so changing the base leaves stale semantics with no failing test. Expressions preserve the intent; and an explicit both-directions dependency list (follows / must-not-follow) is what makes a base-parameter change reviewable.
Applies when
- changing gait clock, control frequency, or units
- a reward threshold interacts with a phase/window duration
- config audit finds literals that encode ratios
“feet_air_time 阈值 0.25 是写死的,不跟 ct 走——0.40 时摆动窗 ~0.20s<0.25(恒拉长压力),0.50 时摆动窗 ~0.25s≈阈值(语义翻转)。按比例保原压力:0.25 → 0.3125(=0.625×ct;建议直接写成 0.625 * ct 表达式,一劳永逸)。”
train/WALK_V10_SPEC.md § 3. T —— 慢时钟 (训练侧必做一件) The fallen-state reset was designed, not sampled from SO(3) - fixed category shares with jitter, a low drop that settles physically, equal left/right shares for mirror augmentation, and a numeric check before training
fallen-pose-reset-distributionBuild a fallen-start distribution from named, physically plausible categories with jitter and a settle phase, keep mirrored categories at equal probability, and check the realized shares and penetration numerically before spending a training run on it.
Symptom
A get-up policy can only learn from the fallen states its resets produce; uniformly random orientations produce ground-penetrating and limit-jammed states the robot can never be in.
Context
R0 reset_root_fallen: supine 30%, prone 30%, side_l 15%, side_r 15%, mid (random axis 50-125 deg) 10%, +/-15 deg jitter, full yaw, dropped from 0.28-0.40 m and left to settle under physics, joints uniform inside the soft limits with a 5% margin plus small random velocities. Random SO(3) was rejected (the advisor agreed). side_l and side_r must have equal probability because mirror augmentation turns a left fall into a right fall. The advisor had proposed supine and prone only for R0; the spec included side and mid because the feasibility accounts showed physical solutions for all of them, and wrote "narrow back to supine+prone" down as the first fallback. With no display on the training box the reset was checked numerically instead of by eye.
Change
Category mix as above; realized shares, settle height and penetration measured over 512 envs before the first run. A fallen-state bank (real falls, settled and stored) was pre-registered for R2.
Outcome
Realized shares 29.3/31.6/16.4/17.8% against the config, settle +0.262 m, final penetration 0/512 (a 0.10 m peak at the write instant, ankle links only, pushed out within 80 ms because the 0.28 m drop floor is shorter than a fully extended leg). R0's failure was a reward basin, not a reset artifact. The fallen-state bank stayed unbuilt through V3.1 (checklist item open); R0.3 later re-sliced the prone share into roll_l/roll_r bands, which is what forced the acceptance distribution to be frozen separately.
Mechanism
A category-structured, physically settled start distribution keeps training on states the robot can actually occupy, and equal mirrored shares keep mirror augmentation a pure doubling of data rather than a bias.
Applies when
- designing reset distributions for get-up, recovery or multi-contact skills
- mirror/symmetry augmentation is on and the task has chiral start states
- no viewport is available to inspect resets on the training machine
“角度 jitter ±15°、yaw 全域、0.28~0.40 m 低空放下由物理沉降,关节软限位内 均匀(留 5% 余量)+ 小随机速度。**不用 random SO(3)**(会采出穿地/极限卡死 等现实不可能状态,顾问同判) … side_l/side_r **概率必须相等**(镜像增强的样本同分布前提)”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §3 R0 任务定义 / §9 核查单 The 1.5 Hz step-frequency gate was retracted - the author had misread his own actuator data, and the limit fought pendulum dynamics
gate-threshold-retracted-frequencyEvery gate threshold must cite its measurement and survive a first-principles sanity check; when a gate keeps failing otherwise healthy behavior, re-derive the threshold from the raw data before enforcing it again - and retract wrong gates in writing.
Symptom
An acceptance criterion "step frequency <= 1.5 Hz" kept failing healthy policies (walk_v4 at 2.33 Hz), and an earlier attempt to force slower stepping (v3) had killed stepping altogether.
Context
The threshold had been derived from the author's own actuator frequency-response measurements - but re-reading the raw table showed the misread: amplitude ratio at 2.0 Hz is 0.88 (knee) / 0.83 (ankle), acceptable; the genuinely bad point was walk_v2's 3.8 Hz at 0.58. Mechanism check agreed: the leg as a compound pendulum (L ~ 0.30 m) has a natural frequency ~1.1 Hz, swing half-period 0.45 s - the observed 2.1-2.4 Hz sits near where the leg wants to swing, and forcing 1.5 Hz "是跟摆动动力学对着干" (fights the swing dynamics). The frequency definition itself was pinned by two independent methods (contact-event counting 2.39 Hz vs FFT 2.33 Hz, agreeing): reported numbers are cycle frequency = steps per leg per second.
Change
Gate retracted in writing: "步频 ≤1.5 Hz 应删除或放宽到 ≤2.5 Hz"; frequency definition standardized before entering any config.
Outcome
walk_v4/v6's 2.1-2.4 Hz reclassified from disease to normal; the v3 failure got its probable explanation (suppressing stepping to meet a wrong gate).
Mechanism
A gate is only as good as the measurement and the reading behind it; thresholds inherited from a misread plot become invisible design constraints that later training obeys at real cost. Cross-checking a threshold against first-principles dynamics (pendulum frequency) is a cheap way to catch such misreads.
Applies when
- an acceptance threshold repeatedly fails policies that look healthy
- thresholds were set from a single person's reading of raw data
- a forced compliance with a gate degrades the behavior it guards
“我当初依据自己测的执行器频响定的,但看错了区间。… 2.0~2.4 Hz 的幅值比 0.83~0.88 是可接受的;真正不行的是 walk_v2 的 3.8 Hz。… 腿按复摆算(L≈0.30 m)自然频率约 1.1 Hz … 把它压到 1.5 Hz 是跟摆动动力学对着干(walk_v3 把迈步压没了,可能正是这个原因)。”
train/WALK_DIAGNOSIS.md § ② 撤回"步频 ≤1.5 Hz"这条验收标准 —— 是我定错了 Prove an armless get-up exists before training it - a connected static domain, 25% torque on the cheapest path, an 8 mm hand-over gap, a static roll-over - and write down what each scan cannot represent
get-up-feasibility-accounts-before-trainingBefore training a get-up or any multi-contact skill, compute the quasi-static accounts - connectivity of the static domain, torque along the cheapest path, hand-over gaps, COM shift available for rolling - and state which configurations each scan cannot represent; when a policy gets stuck in one of those, extend the scan before blaming the reward.
Symptom
A torso-and-legs robot has no arms to push off the ground; whether it can get up from the floor at all was unknown when the line opened.
Context
recovery_feasibility.py ran three accounts before any training (the run line's "hard accounts first" discipline): a sagittal quasi-static scan (0.05 rad grid, 44,520 configurations, MuJoCo FK, flat-foot assumption). (1) The static standing domain (COM over the feet, torques in limit) has 29,586 cells, flood-fill connected with no islands, from a 0.097 m deepest squat to the 0.384 m stand. (2) The minimum-torque path peaks at 25% of the limits (knee 2.9/12, ankle 3.7/17 N*m) - a 4x margin. (3) All 508 ground-contact configurations have the contact behind the COM; the smallest gap to pure foot support is 8 mm. A roll-over account: swinging both straight legs to one side shifts the COM 96 mm against a 62 mm torso half-width - 1.6x, so rolling needs no momentum. Three conclusions were written down for later attribution: the legs are 80% of the mass (swinging them moves the COM), prone has no flat-foot hand-over face (merge into a supine/side sit first), and supine needs no sit-up (hip flexion is limited to 75 deg).
Change
The accounts gated opening the line and were cited in every later argument about what the robot can physically do.
Outcome
They held where they applied: in V1.0 every fall category was righted under a hard rate limit, which the spec records as the quasi-static roll-over account verified by training, and the 25% torque path was the basis for pursuing a slow get-up. They also misled once: account (3) is sagittal, and on 08-09 the spec corrected its scope - it cannot represent the splayed W-sit where the policy actually stalled. A follow-up prone hip-ROM scan (471,625 cells) found 3,912 two-foot-contact cells and none with both soles within 25 deg of level (best 40.2 deg): a flat-footed push-up from prone is infeasible on this robot, so the fix became where the feet go after sitting up.
Mechanism
A get-up needs a connected path through statically feasible configurations and enough torque along it; quasi-static accounts bound both cheaply, and momentum can only make the real problem easier. A reduced-dimensional scan, though, only speaks for the configurations it can express.
Conflicts
In R0.1-R0.2 the spec read account (3)'s "prone has no front hand-over" as "prone lacks the roll-over skill"; R0.3's confusion matrix showed prone had righted its torso 159/159, and the spec then restricted account (3) to the sagittal configurations it models.
Applies when
- opening a get-up, recovery or climbing skill on a new robot
- a robot lacks arms or other obvious contact options
- a policy stalls in a configuration a feasibility scan never modelled
“本机 **torso + legs、无手臂可撑地**,开训前先证明存在不依赖手臂的物理解 … 双腿同侧直腿摆最大横移 **96 mm = 1.6×** … **静态摆腿即可翻身,无需动量**”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §1 机械可行性判决(2026-08-09,recovery_feasibility.py 三笔账) Brief the operator on the lineage's measured zero-command and untrained-axis behavior before handing over the joystick
know-zero-command-behaviorBefore any teleop/demo, measure and write down the policy's zero-command behavior and per-axis competence, label untrained axes explicitly as not-bugs, and set the floor/procedure to accommodate the known drift.
Symptom
A teleop session was about to start on a policy that does not stand still at zero command and has never been trained on lateral commands - behaviors an unbriefed operator would report as bugs or emergencies.
Context
Three measured facts were written into the teleop instructions ("都有 实测依据, 不是猜"): (1) A/D (lateral) keys will get essentially no response - probe-measured sidewalk tracking ~3%, an untrained axis: "这正是 C4 要解决的事, 不是 bug"; (2) no keypress = cmd 0, and this lineage does not stand still at zero command - a three-generation lineage property: paces in place, drifts right ~5 cm/s, net rotation -30 deg/20 s; sim survival is 20/20 (it will not fall) but it walks away slowly, so leave floor margin especially on the right; (3) S (backward) WILL respond - probe-measured 20/20 survival, 67% tracking untrained, which is also why this root was chosen for the C ladder. Plus a keybinding dry-run while suspended before touching down.
Change
Operator briefing became part of the deployment artifact: expected response per key, expected idle behavior with magnitudes and directions, and the distinction between untrained (expected, not a bug) and abnormal.
Outcome
The session proceeded with correct interpretations available in advance; the known zero-command wander was handled by floor margin and start-with-command procedure rather than misdiagnosed on the spot.
Mechanism
A learned policy's off-nominal behaviors (idle drift, untrained axes) are lineage properties, stable and measurable in sim beforehand; operator surprise converts known properties into false incident reports and unsafe reactions. A briefing transfers the measured behavior model to the person holding the controller.
Applies when
- handing a learned policy to an operator or demo audience
- the policy idles in a non-stationary way at zero command
- some command axes are untrained in the current lineage
“A/D 基本不会有反应 —— s1e 从未训过非零 vy, 选根探针实测侧走跟踪率 ~3% … 这正是 C4 要解决的事, 不是 bug。… 不按键 = cmd 0, 而 s1e 在零指令下不站定 —— 血统属性, 三代实录: 原地踏步 + 右漂 ~5 cm/s + 净旋 −30°/20s。”
train/REAL_RUN_S2.md § 附: WSAD 遥控 上机前必须知道的三条 When a contract default changes, old policies must run under a pinned legacy profile - a silent clock swap is out-of-distribution on hardware
legacy-profile-pinningTreat every trained policy as bound to the contract values of its training era: version the deployment profiles, pin old policies to their era's profile in every command, and never let a changed default silently apply to an old artifact.
Symptom
The walk profile's gait clock moved from 0.40 s to 0.50 s for new training, but versions v5-v9 were all trained at 0.40 s - running them under the updated default would silently feed a 25% slower phase clock to policies that never saw one.
Context
The re-test runbook hard-codes --policy-profile legacy_walk_040 into every command for the old versions, with the warning not to omit the flag: the mismatch is invisible (no error, no crash) but puts the policy out of distribution on hardware, where the same file had already documented that off-clock operation collapses gait quality.
Change
Deployment profiles versioned per training era; historical policies permanently associated with their era's profile; runbooks write the profile flag explicitly rather than relying on defaults.
Outcome
Old policies stayed runnable and comparable after the contract moved on; the silent-mismatch failure mode was closed by convention.
Mechanism
Changing a shared default rebinds every old artifact to a contract it was not trained under; unlike a schema break, a value change produces no error - only degraded, unexplainable behavior. Version-pinned profiles make the binding explicit and permanent.
Applies when
- changing any default in the deployment contract (clock, scales, gains) while old policies remain in use
- writing runbooks that mix policy generations
- a re-tested old policy behaves worse than its era's records
“2026-08-02 起 walk profile 的时钟改为 0.50(WALK_V10_SPEC §3)。v5~v9 全是 0.40 训的,本文件所有命令已改带 --policy-profile legacy_walk_040 ——不要省掉这个 flag,否则是拿慢 25% 的相位时钟静默喂旧策略(分布外,真机危险)。”
train/REAL_SWEEP_V5_V8.md § 1. 预检 ⚠️ 时钟改为 0.50 Multiple changes may share one rung only if their symptom spaces are orthogonal - with the ablation order written in advance
orthogonal-batch-with-ablation-orderBatch changes into one rung only when you can name each change's private symptom space in writing; pre-register the ablation order (numeric before structural) and per-change escalation plans, so a mixed outcome decomposes without new decisions.
Symptom
v8 needed four repairs at once (saturation cheating, landing impact, leg narrowing, heading alignment) - strict one-variable laddering would have cost four training cycles for wounds that were all already diagnosed.
Context
The batch was allowed because each change owns a disjoint symptom space, stated explicitly: "A→形态/饱和, B→落地/步态高度, C→腿距/roll 摇摆, D→偏航/转向" - so a single run can attribute each outcome to its change by which symptom moved. For the failure case, the ablation order was pre-registered (A2 -> A1 -> B -> D -> C, "先撤数 值改动" - retract numeric tweaks before structural ones), and every change carried its own escalation/rollback plan (e.g. A insufficient: joint_pos_ref 1.6->2.0 or widen the exp kernel; B overdone - robot afraid to land: v_ok 0.30->0.45; D unstable: rel 0.5->0.25, not back to 0).
Change
Four-change rung executed as one run with per-change symptom ownership, per-change contingency plans, and a pre-registered global ablation order for unattributable regressions.
Outcome
The rung retained single-run attributability without paying 4x training cost; the contingency table meant no failure mode would require improvising an ablation under pressure.
Mechanism
The one-variable rule exists to keep attribution possible, not as an end in itself; attribution survives batching exactly when the changes' observable effects are separable. Orthogonality is a claim that must be argued per pair in advance - and the pre-registered ablation order is the escape hatch for the case the claim fails.
Applies when
- several diagnosed fixes are queued and ladder time is scarce
- deciding between strict laddering and a combined rung
- a combined rung shows a regression no single change explains
“四个改动症状空间基本正交,可单 run 归因:A→形态/饱和,B→落地/步态高度,C→腿距/roll 摇摆,D→偏航/转向。出现无法归因的整体退化时消融顺序 A2→A1→B→D→C(先撤数值改动)。”
train/WALK_V8_SPEC.md § 8. 风险与归因 Push-test protocol - positive side first, fragile side spotted, axes aligned in the log, and cross-machine push counts stay qualitative
push-test-chirality-protocolOrder disturbance tests from the robust side to the fragile side with protection scaled to sim-measured asymmetry, align and log frame conventions before testing, and treat cross-domain disturbance counts as qualitative evidence only.
Symptom
Hand-push testing on hardware risked falls on a side sim had already flagged as fragile, and push counts invited apples-to-oranges comparison with sim numbers.
Context
Sim chirality was explicit: descendants were far more fragile in -y (fric-3000@kd1.2: +6 N*s survived 15/20 vs -6 N*s only 3-9/20) while the s1e control was perfectly symmetric (40/40). The protocol therefore: push the positive direction first, keep a spotter for the negative side; before any push, record which real-robot side corresponds to sim's +y in the log ("上机前对一次坐标"); and - citing the chaos lesson ("混沌课文") - real push results are used only as qualitative corroboration, never compared numerically with sim survival counts across machines.
Change
Push testing became a scripted, chirality-aware protocol with frame alignment as a logged precondition and an explicit epistemic limit on cross-domain count comparison.
Outcome
The fragile side was tested with protection informed by sim's quantified asymmetry; logs stayed interpretable because the frame correspondence was recorded before the first push.
Mechanism
Disturbance-response chirality is a real, quantifiable lineage property, so test order should follow measured fragility; and perturbation outcomes are chaotic in the details (divergent trajectories from tiny differences), so counts do not transfer across domains even when qualitative rankings do.
Applies when
- planning push/disturbance tests on hardware
- sim shows directional asymmetry in disturbance survival
- someone proposes comparing real push counts to sim counts
“先正向后负向, 负向留人扶 —— sim 手性明确: 后代在负 y 向显著更脆 (fric-3000 @kd1.2: +6 N·s 15/20 vs −6 N·s 3~9/20), 而 s1e@0.8 两向 40/40 完全对称。上机前对一次坐标 … 跨机不做二值结论 (混沌课文): 真机推力只作定性对照, 不与 sim 计数对比。”
train/REAL_RUN_S2.md § 3. 抗推 (可选, 人手推; 做则按此协议) A field experiment is allowed when it is pre-scripted, single-variable, and self-reversing (RAM-only writes)
reversible-single-variable-field-experimentsPermit hardware-side experiments only when scripted in advance with one variable, a log, and automatic reversion (volatile writes, git restore); keep every config mirror (yaml vs firmware) changed and restored as a unit.
Symptom
A hypothesis needed a hardware test - v5's "wild kicking" might trace to the RS00 torque cap being deployed at 11 N*m vs its trained 14 (-21%), on exactly the ankle-roll/hip-yaw joints doing lateral-yaw work - but changing limits in the field is the classic way to lose track of robot state.
Context
The experiment was written to be safe by construction: change exactly one number (robot.yaml RS00 tau_limit 11.0 -> 14.0), write to firmware RAM only (--write without --save, so a power cycle automatically rolls back to the saved 12/17/11), run the single logged trial, then restore both yaml (git checkout) and RAM immediately. The consistency requirement is explicit: the deploy tool's torque self-check compares against robot.yaml, so yaml and firmware must change and restore together; and the hypothesis scoping is itself single-variable - RS06's 67% cut was measured irrelevant (gait uses only 16% of rated) and hip torque was left alone for safety.
Change
Field experimentation policy refined: not "never touch hardware settings" but "only pre-scripted, one-variable, logged, auto-reverting changes with config/firmware kept consistent".
Outcome
The sub-experiment could answer the torque-cap hypothesis without any risk of the robot persisting in an undocumented state - forgetting to restore costs nothing but a git checkout.
Mechanism
The danger of field changes is state divergence (robot config drifting from the repo's record), not the change itself; volatile (RAM-only) writes bound the divergence lifetime to one power cycle, and single-variable scoping preserves attributability even in a field setting.
Applies when
- a hypothesis requires changing firmware limits or gains on the robot
- field debugging tempts persistent config writes
- designing safe escape hatches for deployment tooling
“程序(--write 不带 --save = 只写 RAM,断电自动回滚)… deploy 的限扭自检是对 robot.yaml 比对的,所以 yaml 和固件必须同改同还原;忘了还原也没事,断电重启即回 12/17/11(上次 --save 的值),但 yaml 要 git checkout。”
train/REAL_SWEEP_V5_V8.md § 4. 限扭子实验(可选二期,只对 v5,单变量) Four consecutive fixes were each continued from the previous fix's degraded state until the user stopped the ladder - "change parameters, don't stack errors" - rolled back to the last good checkpoint and audited the target geometry first
stop-stacking-roll-back-and-auditWhen successive rungs each start from the previous rung's output and the target symptom does not move, stop, roll back to the last good checkpoint and re-derive the next change from an audit; keep the measurements, discard the stacked remedies.
Symptom
After the real-robot splits, the V2.7 ladder tried to widen the stance: a term swap (A), a new stance knife (b), more iterations (甲), a doubled weight (乙). Stance barely moved while hip yaw ratcheted 46.7 -> 49.9 -> 52.5 deg toward its 60 deg limit.
Context
Each rung started from the previous rung's output. The user ruled on 2026-08-11 that things had gone wrong from V2.7-A: go back to v2_6 and rethink which parameters to change instead of stacking errors.
Change
乙 was killed at start and not counted; the product baseline rolled back to v2_6c model_29399; every measurement and law learned on the ladder was kept ("the data is real; what stacked was the treatment"). Before any new training, a zero-training kinematic audit of the stance targets was run.
Outcome
The audit found the stand_pose target itself rewarding the narrow stance (pose-target-geometric-audit) and showed geometrically why the yawed stance could not be widened with flat feet - so 乙 was proven unnecessary without running it. The next in-lineage attempts still failed, which is what established that the stance is set by the get-up path.
Mechanism
A rung continued from a degraded state inherits its compensations, so each new fix answers the previous fix's side effects; the yaw ratchet was the visible trace of that stacking.
Applies when
- three or more corrective rungs in a row without progress on the target metric
- a side-effect metric ratchets in one direction across rungs
- a new rung is being planned from the latest (not the best) checkpoint
“用户裁:"从 V2.7-A 开始就出问题了,应该回到 2.6 再思考如何改变参数而不是 错误叠加。"认账:A 的补丁 → b 的新刀 → 甲的加时 → 乙的加权,每级都从上级 的**退化状态**续(yaw 46.7→52.5° 的棘轮就是叠加痕迹)。 … 数据是真的,叠加的是处置。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §44 方法论裁定(2026-08-11,用户):V2.7 全阶梯叫停,回滚 v2_6 A suspended (no-load) test acquits or convicts the actuator before you blame authority
suspended-test-isolates-actuator-authorityBefore attributing a failure to actuator authority, measure no-load tracking error and steady-state torque fraction; blame authority only if the task fails while the error grows with demanded force - and then fix gains or targets, not training.
Symptom
hip_roll sagged 0.21 rad on the ground and saturation questions loomed over the sidewalk plan - was the roll axis physically too weak (authority), or was something else limiting it?
Context
Before C4, the roll-authority question was settled by measurement triage: suspended test (--suspend, feet off ground) showed hip_roll tracking error 0.0008 rad - actuator acquitted; the entire 0.21 rad ground sag is load-induced. Steady-state torque was 25% of limit - 75% margin remains. Since sidewalk needs lateral force, not exact angles, authority was ruled "not a hard limit", with a pre-registered criterion for when it WOULD become one: sidewalk fails to track AND roll error keeps growing - then the fix is raising hip_roll kp or lowering the vy target, not more training.
Change
Hypothesis "roll authority insufficient" demoted from blocker to a monitored branch with an explicit trigger condition; C4 proceeded.
Outcome
Later open-loop probes confirmed the actuator could produce the behavior (sidewalk feed-forward ran at full amplitude, 5/5 survival), and the eventual C4 failure causes were measurement and reward, never authority.
Mechanism
Suspended vs loaded comparison separates the actuator's closed-loop competence from the load path: tiny no-load tracking error means the motor/controller is fine and any loaded deviation is statics (gravity / stiffness budget, kp trading error for force). Torque-fraction measurement then bounds how much force headroom actually remains.
Applies when
- suspecting an axis is "too weak" for a new skill
- large position sag on a loaded joint
- deciding between hardware fix, gain change, and more training
“吊挂(--suspend)实测 hip_roll 跟踪误差 0.0008 rad → 执行器无罪,地面下垂 0.21 rad 全是负载所致;稳态占限扭 25% → 仍有 75% 扭矩余量。… 判据:若 C4 出现「侧走跟不动且 roll 误差继续变大」,那才是权限账 … 解法是提 hip_roll 的 kp 或降 vy 目标,不是硬训。”
train/C_LADDER_RUN.md § 3d. roll 权限:已部分澄清,不是硬上限 Add a termination that makes the degenerate strategy fatal - no height cut-off meant crouch-shuffling could live forever
termination-closes-degenerate-basinFor each known degenerate strategy, check whether the termination set makes it fatal; if the robot can live indefinitely inside the degenerate posture, add a termination just past the intended operating envelope rather than escalating penalties.
Symptom
Crouched foot-dragging survived indefinitely because the termination set contained only bad_orientation (40 deg) and base contact - there was no height termination at all, so a deep squat was a viable long-term strategy.
Context
The hypothesis audit found the missing termination (hypothesis 7); the cross-check against published configs found the field practice: Booster terminates at 0.45 m (38% of body height) and the research warning is that the termination height must not be so low that crouching survives it. The proposed value: 0.32 m, just below the walk crouch base height 0.3739 - a deep squat terminates immediately, "断掉蹲着蹭的活路" (cutting off the crouch-shuffle's livelihood).
Change
Add height termination at 0.32 m as a second-priority item of the walk fix package, alongside restoring base_height_l2 to -10.
Outcome
Entered the v5/v6 fix package under which the crouch-shuffle optimum disappeared (34 mm clearance, 87% tracking by v6).
Mechanism
Termination conditions define which strategies exist at all: a reward penalty prices a behavior, but a termination deletes its future returns entirely. Degenerate basins that are merely penalized can remain optimal under enough tracking pressure; a termination placed between the degenerate posture and the intended one makes the basin unreachable as a steady state.
Applies when
- a degenerate but stable behavior persists across reward tunings
- auditing termination conditions for a locomotion task
- a policy exploits the gap between penalized and terminated states
“加终止高度:研究第 6 条"终止高度不能低到让蹲着也能活"。我们完全没有高度终止。建议 0.32 m(略低于 walk 蹲姿基座高 0.3739,深蹲即终止)。… 加终止高度 0.32 m(深蹲即终止,断掉蹲着蹭的活路)”
train/WALK_DIAGNOSIS.md § 修正 ④ / 最终改动清单 第二优先