Training Coach
Doctrine
A report may cite any of these as doctrine-N.
doctrine-1Contract freeze and fingerprint disciplineThe policy I/O contract (observation layout, scales, history semantics, action pipeline) is frozen and fingerprinted; every exported policy is stamped and verified; contract changes ship as new versioned profiles that leave old artifacts bit-identical, and old policies run forever under their era's pinned profile.
Case. The 215-dim omni contract was frozen with a three-machine digest; the one contract-level extension (lateral feed-forward) went in as a new `omni_ff` profile with the old profile provably untouched, and the contract checker caught two real wiring bugs before any training (`contract-freeze-and-checker`). A silently changed gait-clock default would have fed old policies a 25% slower clock - closed by pinned legacy profiles (`legacy-profile-pinning`). A stale derived USD forked plant mass 2.2% until an automated source-vs-derived instrument gated it (`derived-asset-staleness-check`). A gain profile is part of the closed loop a policy was trained in and belongs in its stamp; the recovery line's anchored authority was left out of its manifest and recorded as the gap not to repeat (`gain-profile-belongs-in-the-stamp`), and a second policy behind a deploy-side switch made the handoff state itself a contract (`recovery-two-policies-and-a-state-machine`, `walk-recovery-fsm-handoff`).
Coach application. On any proposal touching obs/action semantics, defaults, or derived assets: demand the version/profile plan, the fingerprint update, and the checker extension in the same change; flag any old artifact that would run under new defaults.
doctrine-2Attribution by resolved training params - never eval-override knobsCapability differences between lineages are explained only by digging each lineage's *resolved* training configuration and eliminating columns; evaluation-side override knobs (kd-scale, power-scale, cycle-time) act on the plant for *every* policy and may serve as deployment mitigations but never as explanations.
Case. Low-friction robustness across 8 lineages x 3840 cells was traced to kd DR *bandwidth* - every lineage had ground friction pinned to (1.0,1.0), so "trained friction" could not be the axis; the parameter axis and the plant axis were explicitly separated after the first attribution conflated them (`kd-bandwidth-mu-law-attribution`). "Weak turning" on hardware was a power-scale plant effect, not a training gap (`deploy-knob-attribution-before-retraining`); slowing the deploy clock was out-of-distribution, not a feature (`cycle-time-override-is-ood`). The ground truth for what a run trained under is the logged per-run config, not the source tree (`resolved-config-is-source-of-truth`).
Coach application. Whenever asked "why is lineage A better", require the resolved-param table first; kill zero-variance columns; refuse explanations phrased in eval-knob terms; when a knob helps, label it deployment mitigation.
doctrine-3PASS gates become constraints; FAIL gates become objectivesOnce a skill passes its gate, that gate converts into a standing regression constraint (budget <= 2/20 against the parent baseline) for all later training; gates currently failing are the only legitimate objectives of the next rung.
Case. The C ladder ran one frozen 13-cell x 20-seed matrix at every rung with promotion = "new skill PASS and old skills within regression budget"; C1 was stopped and re-rooted precisely because it trained away the root's backward PASS (`fixed-acceptance-matrix-per-rung`, `preregistered-stop-criteria-per-rung`). The C4 product shipped only at 260/260 cells with zero regression.
Coach application. Keep the ledger: every PASS adds a constraint row; propose rungs only against FAIL rows; treat any constraint violation as stop-and-attribute, never "the next rung might win it back".
doctrine-4One variable per ladder rung - counted against what the checkpoint sawA rung changes one variable, where "one" is counted against the checkpoint's actual training state, not against the current config's diff; batching is allowed only when each change owns a disjoint symptom space with a pre-registered ablation order.
Case. Two rungs failed identically because resuming s1e-500 under the evolved config silently added four plant variables the checkpoint had never seen ("单变量纪律不只看「我改了什么」,还要看「checkpoint 见过什么」" - `resume-state-dr-audit`). v8 legally batched four orthogonal fixes with a written ablation order (`orthogonal-batch-with-ablation-order`); v9 spent one run completing a 2x2 factorial so either outcome convicted a factor (`fill-the-missing-factorial-cell`); v10b's three-way ablation wrongfully convicted the clock and had to be retried fairly.
Coach application. Before any resume: diff cfg against the checkpoint's logged training state. Before any batch: require the symptom-ownership map and ablation order in writing.
doctrine-5Pre-register risks, readings, and stop criteria before the ladderBefore a ladder or risky rung, write down the known risks, the interpretation of every plausible outcome, and hit-any-one stop criteria - frozen before training, tightened when priors say results should come fast.
Case. The C ladder opened with three numbered risks including the exact falsification condition for its own root choice; A/B arms carried "预注册读法(事后不改)" tables; a level expected to fail was run anyway for its pre-registered diagnostic value (`preregister-risks-and-fork-readings`). Stop criteria caught C4-redo rungs at +200 instead of full caps (`preregistered-stop-criteria-per-rung`); hardware sessions pre-registered per-config expected signatures and the disagreement rule "不改结论改账" (`preregistered-real-expectations`, `feasibility-accounts-lock-design-point`).
Coach application. Refuse to open a rung without the written risk/reading/ stop block; after results, read conclusions off the pre-registered table and flag any post-hoc reinterpretation.
doctrine-6Plant parameters are measured, never inventedEvery plant number carries measurement provenance: armature = N^2 x rotor inertia from no-load tests, friction split by rig and by API column, torque limits shaped by per-joint gait peaks, latency traced through the real pipeline, masses weighed - and DR bands are additive around the measured nominal, sized to the measured dispersion.
Case. Guessed friction was 2.5x low and guessed damping 5x high (`friction-measured-not-guessed`); armature had been 0 with a 9:1 gearbox (81x reflected inertia, `armature-n2-rotor-inertia`); a uniform torque derating was "the wrong shape" vs measured peaks (`torque-limit-shape-by-measured-peaks`); the delay implementation itself was a wrong plant for a whole lineage (`latency-lerp-reverse-extrapolation`); the run design point was locked by three accounts including the tau_limit/kd speed ceiling (`feasibility-accounts-lock-design-point`); identified friction had to land in the right simulator API columns to act at all (`sim-api-friction-columns`). The recovery and one-leg lines opened with the same kind of accounts before any reward existed - a connected static path and the torque along it for an armless get-up, and the gains single support needs to be holdable at all (`get-up-feasibility-accounts-before-training`, `single-support-gain-authority-probe`).
Coach application. For any plant value in a config review, ask "measured how?"; reject absolute ranges with no nominal; check API column mapping and derived-asset regeneration whenever measured values land.
doctrine-7Sim2sim gate before sim2real - under deployment conditionsEvery checkpoint passes a second, independently built simulator before hardware, and both the gate and the smoke loop run under the measured deployment conditions (real pipeline delay, honest contact parameters, the deployment gain/power profile).
Case. The standing order "先sim2sim 再sim2real" (`sim2sim-gate-before-sim2real`); acceptance flipped to match hardware only under measured condim/torsional friction (`eval-plant-honesty-contact-params`); gates moved permanently to `--delay 2` after the kicking incident (`pipeline-latency-is-plant-not-dr`); and the harness itself must be audited - a frame-convention bug in the cross-sim evaluator invalidated a whole line of verdicts (`body-frame-velocity-api-audit`). The recovery line's second simulator caught a torque penalty paid for by bracing the legs together (`torque-penalty-bought-by-leg-bracing`), and a 1.8x torque disagreement between the two plants stayed binding because its one surviving explanation was never tested (`torque-disagreement-between-simulators-unresolved`).
Coach application. Block any hardware request lacking a second-sim PASS at deployment conditions; when sim2sim and training-side metrics disagree, treat the evaluator as a suspect too.
doctrine-8Observation honesty - the actor's inputs are a hardware contractThe actor observes only signals the real robot produces with realistic noise; privileged truths go to the critic; history windows are estimators and must train under plant variation; rewards on quantities the actor cannot observe buy only average suppression, never closed-loop correction.
Case. Ground-truth velocity/forces went critic-only (`observation-honesty-critic-only`); frame_hist under zero DR memorized the trainer's plant fingerprint - 0/20 transfer (`history-obs-needs-plant-variation`); world-frame yaw rewards could not teach pull-back because heading is unobservable to the actor - correction was routed to the deploy outer loop instead of breaking the contract (`reward-observability-limit`, `deploy-heading-loop-and-align-training`).
Coach application. Audit every actor-obs element for hardware existence; require minimal plant jitter whenever history/recurrence exists; for each reward, ask "can the actor see this error?" and route correction tasks to outer loops.
doctrine-9Reward economics are audited in realized currencyReward design decisions are made on realized per-step magnitudes under the actual policy and command distribution: price the do-nothing optimum before adding a mode, compare achieved values to the computed ignore-floor, calibrate thresholds between measured healthy and sick distributions, and ship every new penalty with a withdrawal clause.
Case. feet_air_time at weight 2.0 realized 0.038 vs tracking 1.2 - drag was rational (`realized-contribution-audit`); ignoring a vy command cost 28-180x less than ignoring vx until a gated tracking term was added (`reward-cost-of-ignoring-audit`, `gate-new-reward-terms-by-command`); achieved-vs-floor separated "never learned" from "priced out" (`ignore-floor-diagnosis`); the foot-distance wall was placed between measured healthy (0.6% tax) and sick (55%) policies (`calibrate-threshold-between-healthy-and-sick`); the landing penalty carried a pre-registered stand-down condition and actually stood down (`calibration-threshold-with-withdrawal-clause`); two clearance terms were inert until zero-points and gate occupancy were checked (`inert-reward-term-audit`). A get-up policy sat because three gated terms paid the seated pose 84% of the return and the one term that could tell sitting from standing was an exp kernel reading 4.6e-5 at the real error (`seated-basin-dead-exp-kernel`); a torque-tail term was weighted by its measured steady value beside a peer term after the estimate proved 12x off (`tail-torque-needs-hinge-on-computed-demand`).
Coach application. Never discuss weights in the abstract: demand the realized-contribution table, the ignore-floor number, and the healthy-pay calibration before any reward edit is approved.
doctrine-10The zero-cost option must be the desired behaviorFor every penalty, name what the zero-cost option is; penalize failure events (slip, saturation excess, contact in flight windows), never the motion or joints that healthy behavior uses; make degenerate strategies fatal via termination where penalties cannot price them out.
Case. Joint-usage penalties for drift taxed a 1.4%-of-momentum channel 2.7/step and collapsed training; the slip penalty costs a non-slipping gait exactly zero (`penalize-the-slip-not-the-joint`). A frozen-at-clamp joint pays zero action-rate forever - only a pre-clip saturation penalty flips the cheat economics (`saturation-cheating-zero-rate-cost`). Ungated phase shaping made standing 42x more expensive than stepping and cooked the hip motors (`moving-gate-42x-stand-tax`); crouch-shuffling lived until a height termination deleted it (`termination-closes-degenerate-basin`). A gated penalty is an exit: the policy parked just outside an uprightness gate, then just under a height gate, to stop paying a stance tax, and only a positive band plus an always-on guard closed both (`penalty-gate-is-an-escape-hatch`); a soft-limit penalty that charged the standing pose itself bought a 4.1 deg lean (`soft-limit-penalty-charges-nominal-pose`); an unpriced foot attitude was spent on edge-standing (`unpriced-foot-attitude-is-a-free-variable`); and the one-leg line listed its cheapest cheats before training and still met one through a zero-gradient band (`enumerate-cheapest-cheats-before-training`, `binary-band-reward-fake-touchdown`).
Coach application. Run the "零代价的选项是什么" audit on every proposed term; convert motion taxes into event-conditional penalties; check the termination set against each known degenerate strategy.
doctrine-11Measurement discipline: independent referees, signs, distributionsA disputed measurement is adjudicated only by an independent algorithm from raw state; directional ability requires sign-antisymmetry under command reversal; bimodal metrics are reported as mode shares (never medians, never 3 seeds); ratios are not comparable when totals change; reward values compare only within one command distribution; single chaotic events never cross machines.
Case. The triple reversal - a good metric was "refuted" by a sibling metric that shared the disease (`independent-referee-for-metric-disputes`, `body-frame-velocity-api-audit`); same-signed +/- responses were bias, not turning (`same-sign-response-is-yaw-bias`); the swing median sat in a bimodal gap (`median-hides-bimodal-distribution`); "v6 is jitterier" died on absolute energies (`ratio-metrics-need-absolute-check`); yaw gain measured 15x wrong in an oscillating frame (`heading-integral-not-body-rate`); a 44% improvement evaporated under same-distribution comparison (`same-distribution-reward-comparison`); drift direction was a limit cycle (`multiseed-sign-test-for-drift`); a cross-machine push cliff was chaos (`single-impulse-recovery-is-chaotic`).
Coach application. Before accepting any surprising number: ask for the independent recomputation, the sign pair, the distribution shape, and the comparison conditions. Retract in writing when a metric falls.
doctrine-12The deployment pipeline is plantIrreducible pipeline properties - action latency, rate limits, power/torque scaling, teleop command mappings - are part of the nominal plant, modeled from day one and reproduced in every gate; deploy-side scalings are crutches that flag unmodeled plant, and they cannot be algebraically folded into training constants.
Case. Right-leg kicking was over-trained-delay x loop gain; power 0.8 was a gain-reduction crutch that retired when the delay was modeled (`pipeline-latency-is-plant-not-dr`); power derating damages non-forward axes first (`power-scale-hurts-nonforward-axes`); training at 0.4 scale as the "twin" of deploying 0.5 x 0.8 collapsed 0/20 (`deploy-scaling-not-training-equivalent`); one shared teleop speed sent an out-of-band lateral command and the robot clipped its own foot (`teleop-command-band-per-axis`); the latency DR range had not even covered the measured pipeline (`latency-dr-covers-measured-pipeline`). A rate limiter added at deployment only clipped a policy that kept commanding (`deploy-rate-limiter-windup`); moved into training and anchored on the last command it became an integrator in the balance loop (`slew-anchor-is-an-integrator`); anchored on the measured angle it bounded torque and kept the bandwidth (`beta-anchored-action-target`). The walking lines' safe setting, power-scale 0.8, cut the ends of the recovery policy's full-range travel and left its spikes alone; a gain inside the trained band did the job (`power-derating-cuts-full-range-contract`).
Coach application. Demand the measured pipeline latency/limits in the plant model and in gate conditions; treat every deploy-side derating as a question ("what is this compensating?"); block per-axis command sources that exceed training bands.
doctrine-13DR budget is finite; its distribution is the measured supportRobustness is a conserved budget: disturbance training on an already-hardened lineage borrows from existing margins; DR ranges span the measured deployment support - no fictitious tails (they buy degenerate gaits), no single constants (they allow thin-margin specialization); harden the plant only after the task distribution is final.
Case. The same push dose helped a narrow lineage and damaged a balanced one - budget conservation (`push-dr-conditional-budget-conservation`); wide latency tails bought drag-glide, constant values shipped 60% thinner tilt margins - the answer is a narrow band on the measured support (`dr-tail-plant-continuation`, `constant-value-dr-overfits-margin`); task-first ordering because hardening a soon-to-change task wastes budget (`task-shaping-before-plant-hardening`); COM randomization used deliberately as a behavior-shaping tool, and rolled back on symptom per its own contract (`com-randomization-forces-leg-spread`, `com-dr-rollback-on-symptom`). DR that is switched on can still be thin: the run policy fell in the frontal plane its gain-and-latency randomization never touched (`thin-dr-judged-by-channel-coverage`), and a friction priority settled under one action contract had to be re-measured under the next (`friction-priority-re-measured-after-plant-change`).
Coach application. Before any DR rung: check the untrained policy against the spec, the lineage's current DR load, and the measured real-world range; after it: audit retained margins, not just the new tolerance.
doctrine-14Gates measure what hardware feels: posture, margins, stripped assistsAcceptance batteries carry posture-class rows (tilt max median, per-joint L/R asymmetry, temperature) beside task rows, graded margin columns beside binary gates, chirality scored per side, at least one condition that removes the environment's free stabilization, and validated predictive scalars promoted into the gate.
Case. Three same-shaped judging errors - survival, displacement, wz-difference - all missed what the operator felt; posture metrics had the predictive power (`task-metrics-vs-posture-metrics`, `stand-gate-posture-not-survival`); binary survival saturated and hid a 60% margin gap (`constant-value-dr-overfits-margin`); v5 passed everything on the ground and failed suspended (`suspension-probe-removes-free-stabilizer`); the hip_roll (l+r) scalar predicted real drift direction and ordering and entered the battery (`hip-roll-sum-predicts-lateral-drift`); averages hide chirality (`chirality-scored-separately`); gait-quality gates are judged at speeds that demand a gait (`low-speed-commands-reward-dragging`). The recovery line added the rest of the kit: where failed episodes end, not only where they started (`end-state-confusion-matrix`); a frozen acceptance distribution with a pinned seed (`frozen-acceptance-distribution-and-pinned-seed`); video of the metric rollout itself (`video-as-acceptance-record`); and the admission that a 10 s episode cannot see a stance that fails after a minute (`episode-length-bounds-what-a-gate-sees`). The one-leg line removed a foot-spacing wall that no gate measured, and the feet met on hardware (`removed-wall-returns-on-hardware`).
Coach application. Review every battery for posture rows, margin columns, per-side scoring, and an assist-stripped condition; when operator feel and gates disagree, suspect the metric class first.
doctrine-15Fork and root selection: recoverability, maturity, frozen rewardsChoose fork roots by which candidate's deficits the coming training can pay back (precision is recoverable; lost plasticity, symmetry, and margins are not); prefer mature checkpoints as roots even when younger ones score better as products; never fine-tune through a reward change - continuation is legal only with the reward frozen and plant/DR widening one rung at a time.
Case. s1e-500 beat higher-precision candidates because its exclusive strengths were unrecoverable (`fork-root-recoverable-shortfall`); the b300 arm proved maturity is capital against adaptation shock (`root-maturity-vs-product-quality`); the B-arm scatter/half-recover/collapse signature falsified reward-change fine-tuning and drew the legal boundary for S2 continuation (`fine-tune-reward-change-falsified`).
Coach application. For root debates, build the exclusive-strengths table and ask "which side can be trained back?"; require dual-arm evidence for maturity claims; classify any proposed continuation as reward-frozen or not before approving.
doctrine-16Curricula: verified engagement, lineage counters, disease-phase gatingAutomatic curricula must prove they engage (a saturated ratchet is constant DR wearing a curriculum's name); every ramp counts lineage-cumulative progress, not per-process steps; penalties aimed at late-stage pathologies ramp in after exploration noise decays; difficulty rises on measured per-stratum success, never on schedule.
Case. The s1f ratchet capped at iter 248 and never engaged (`auto-curriculum-engagement-check`); the saturation ramp re-fired at +600 after every resume and no shipped product ever saw the penalty (`curriculum-counter-lineage-steps`); the same penalty worked once gated to the disease phase and became an untouchable mechanism (`gate-penalties-to-the-disease-phase`); record-high aggregate reward hid a fully-failing delay stratum (`aggregate-metrics-mask-subgroup-failure`); bucket share is not a gradient lever (`bucket-share-is-not-a-gradient-lever`). An assist curriculum keyed to a pooled success share was withdrawn on the strength of the categories that already worked (`curriculum-criterion-conditioned-on-lagging-category`); a pace set by per-step income moved only when that income was time-gated (`per-step-income-drives-speed-time-gate`), and the same gate had to be retired in a lineage without the disease (`time-gate-vs-wide-stance-retire-the-fix`).
Coach application. Ask every curriculum three questions: does it engage (show the internal state)? what does it count (process or lineage)? when is it present (against the pathology's phase)? Check where shipped checkpoints sit relative to every ramp.
doctrine-17Probe before training: feasibility first, hypotheses in tablesAfter two failed training attempts at a skill, stop training: demonstrate the behavior open-loop, enumerate hypotheses in a written table audited against actual configs cheapest-first, race one probe per side of the sim2real boundary for hardware-only pathologies, and use suspended tests to acquit or convict actuators before blaming authority.
Case. "在黑暗里试钥匙" - four sidewalk rungs failed until an open-loop probe separated exploration/waveform/authority in one experiment (`open-loop-probe-before-reward-tuning`); the foot-drag mystery fell to a seven-hypothesis config audit (`hypothesis-table-code-audit`); the period-doubling was resolved by racing a reward-side and a plant-side evidence line - and both paid off, one per sub-case (`period-doubling-evidence-race`); the suspended test acquitted the roll actuator in one measurement (`suspended-test-isolates-actuator-authority`). A read-only configuration probe told a wall from a slope in the recovery line's seated basin (`configuration-probe-wall-not-slope`), and the fix it pointed to - where the feet are - took prone from 0/159 to 158/159 (`prone-dead-end-is-foot-placement`); a knob that did not move its variable was recorded as no test of the idea (`dof-vel-penalty-is-not-a-pacing-knob`).
Coach application. When a skill resists training, prescribe the probe before any further reward edits; require verified target trajectories before imitation terms; keep a falsified-fixes list so closed roads stay closed (`amplitude-cut-falsified-yaw-fix`).
doctrine-18External advice is recomputed locally; values transfer as ratiosEvery external suggestion is classified adopt / already-have / modify / trap by recomputing its claim on the local reward table and probe data; numeric values transfer only as dimensionless ratios (to tracking weight, leg length, sqrt(gL), control rate); citations are verified to exist.
Case. "Start vy very small" would have destroyed sidewalk learning on this reward table - the gradient scales quadratically (`external-advice-audit-against-own-arithmetic`); swing-height targets and weights transferred correctly only through leg-length and tracking-ratio scaling (`transfer-ratios-not-absolutes`); the "6-step delay" was refused for lacking a control rate (`latency-dr-covers-measured-pipeline`); a borrowed reference's structure was FK-verified and its amplitude re-derived from the division of labor (`reference-structure-fk-amplitude-division`); retrieval agents fabricated verbatim arXiv quotes - only source-verifiable material was used; and one dismissed suggestion later proved right for a different mechanism, and was credited (`cycle-average-tracking-for-gait-quantities`). An advisor's staged state machine turned out to exist in none of the three papers it cited, and reading them changed the plan (`advisor-paraphrase-vs-paper`).
Coach application. Intercept every "paper X does Y" with the local recomputation; convert absolutes to ratios before comparison; verify quotes; revisit dismissed advice when new mechanisms appear.
doctrine-19Hardware sessions are scripted experiments, not tuning sessionsReal-robot time executes a pre-registered matrix: risk-ordered (baseline first, fragile last with a spotter), stage-gated (suspended smoke before ground), A/B sessions bracketed by a repeated reference run, operators briefed on measured zero-command and untrained-axis behavior, chirality-aware disturbance protocols, no field tuning - the only legal field changes are scripted, single-variable, and self-reversing.
Case. The S2 acceptance sheet (`risk-ordered-real-deployment`, `battery-bracketed-real-ab`, `know-zero-command-behavior`, `push-test-chirality-protocol`, `no-field-tuning-protocol`); the RAM-only torque experiment with automatic power-cycle rollback (`reversible-single-variable-field-experiments`); and the sim-veto rule - even sim's condemnations get one safeguarded hardware check when they judge the purpose-built configuration (`sim-veto-needs-real-confirmation`). The recovery line's first real run went ahead with its preconditions unmet and was stopped as dangerous (`first-real-get-up-violent-stage-one-policy`); after it: a staged hang, mat and floor protocol (`staged-hang-mat-floor-for-get-up`), a fixed power-cycle pre-flight and two-machine discipline (`power-cycle-preflight`, `two-machine-config-discipline`), a fall guard replaced rather than switched off (`fall-guard-becomes-a-state`), and logs that are part of the run (`hardware-log-is-the-attribution-input`).
Coach application. Turn every hardware request into a runbook with order, gates, brackets, briefing, and anomaly plays; refuse improvised parameter changes on the floor.
doctrine-20Close questions in writing; restart when the debt is structuralAudited questions get frozen verdicts with citable wording and an explicit reopening bar; hardware verdicts are dated by deployment-stack and calibration state and expire when those change; and when successive rungs shuffle symptoms without net progress, freeze the lineage as regression baselines, pay the structural debts, and retrain minimal - carrying laws and instruments, not weights.
Case. The chirality and COM questions were closed with frozen wording and "no reopening without new hard evidence" (`frozen-verdicts-semantic-boundaries`); v5/v6's condemnations expired with the deploy stack (`stale-verdicts-under-old-stack`); a 2-degree calibration fix moved the whole runnable envelope (`zero-offset-calibration-shifts-envelope`); plant upgrades are era boundaries with paired re-baselining (`plant-swap-invariants-vs-shifts`); and the 2026-08-05 reset froze v5-v11, fixed the latency FIFO / manifest / sampling / reward-table debts, and restarted - producing the lineage that reached hardware SOTA (`freeze-lineage-fix-structure-restart`, `minimal-reward-table-with-provenance`). The recovery line's real-robot verdicts ended up in three places that disagree, one of them an undated note in a command file (`write-hardware-verdicts-back`).
Coach application. Maintain the closed-questions ledger and quote it when symptoms recur; stamp verdicts with stack/calibration versions; when a team is three rungs into symptom-shuffling, raise the restart question explicitly with the freeze-fix-restart pattern.
doctrine-21Name the quantity in the space it lives inA goal, reward term or acceptance criterion about the feet, the base or the contact state is computed from the quantity itself - world poses, forces, per-category outcomes - never through a joint-angle, single-signal or pooled stand-in that assumes everything else sits at nominal; and every detector is validated on a behaviour known not to contain the event before it becomes a gate.
Case. The recovery line was caught three times: |ankle roll| as "flat feet" sold stance width and the real robot slid into the splits, a hip-roll criterion was confounded by 50 deg of yaw, and the joint table said 0.271 m where the feet were 0.159 m apart; task-space terms produced the first flat, wide stance (`joint-space-proxy-for-task-space-quantity`). Flight detection lied in both directions across two lines - foot height flagged 40% false flight on a walking gait, contact force alone flagged slip chatter as hops (`contact-detector-single-signal-lies`). A pooled height average described a robot that did not exist - six in ten standing, four in ten sitting (`zero-partial-credit-is-not-an-iteration-problem`) - and the walking line had learned the same lesson on yaw rate (`heading-integral-not-body-rate`).
Coach application. For every reward term and gate row, ask what physical quantity it stands for and whether it is measured directly; flag joint-space or single-signal stand-ins for task-space goals, ask for a detector validated on a negative control, and split pooled metrics by category before reading them.
doctrine-22Continuation needs a live gradient; a release is chosen by a scanContinue a converged policy only on a change that creates a live gradient, on a short budget, with every checkpoint scanned on the transfer axis; choose a release by running the full battery over a band of checkpoints and stop on signals, never by taking the last one; and when edits to the terminal phase cannot move a behaviour, roll back and retrain with the constraint present from the start, keeping the order in which the lineage acquired its mechanisms as explicit curriculum phases.
Case. A continuation with no new gradient drifted MuJoCo transfer from 100/98% to 80/28% while every Isaac gate stayed perfect, and a live-gradient continuation at the same depth kept it (`converged-continuation-is-poison`). One-leg checkpoints 100 iterations apart failed 1 and 38 of 40 cells, and late ones degraded (`checkpoint-choice-is-a-full-gate-scan`). Four in-lineage stance fixes failed because the stance was the end of the get-up path, and from scratch it grew right (`stance-decided-by-get-up-path`); fixes stacked on degraded states were rolled back by the user (`stop-stacking-roll-back-and-audit`); and the lineage's final recipe, trained from scratch in one run, sat at 0% because the order of its curriculum was part of the product (`curriculum-history-is-part-of-the-product`). The omni line's short adaptation budgets and mature roots are the same law seen from the other side (`continuation-budget-not-from-zero`, `root-maturity-vs-product-quality`).
Coach application. Before approving a continuation, ask for the new gradient, the budget and the transfer axis in the scan; before approving a release, ask for the scan; after three rungs without progress on the target, propose rolling back to the last good checkpoint and a from-scratch phase plan instead of a fourth patch.
Experience cards
64 cards matching “multiseed-sign-test-for-drift”.
Every power cycle starts with the same read-only pre-flight - read the buses, check the torque limits against 12/17/11, verify the IMU axes, check the ports after any new USB device - and any reassembly re-measures the joint zeros
power-cycle-preflightStart every powered session with a fixed, read-only pre-flight - bus responses, torque limits equal to the simulated ones, IMU axes, device identities - and re-measure joint zeros after any mechanical reassembly before running a policy.
Symptom
Hardware state drifts between sessions in ways no policy can see: a motor that stops answering after a power cycle, a torque limit that differs from the one simulated, an IMU axis flipped, two USB devices swapping identities, a joint zero moved by reassembly.
Context
The runbook's session order before any policy runs: read every motor on both CAN buses without enabling them (the first command after every power cycle); set_torque --check, all twelve motors must read 12/17/11 N*m, and any difference is written back; imu_reader --verify-axes, where the operator tilts the robot forward and to the right and every check must pass before continuing; check_ports after plugging in any new USB device (the IMU and a CAN adapter once collided on USB identity). After re-mounting motors: read the buses, then re-measure the calibration offsets (three repeats, written back) - "skipping it means running everything on the wrong zero". Hanging checklists repeat the torque-limit check (the deploy script also self-checks at start).
Change
A fixed, read-only pre-flight run in the same order every session.
Outcome
The runbook records one earlier hardware check in the same spirit: all 12 motors' implied kp fell within 18.4-22.0 for a commanded 20, inside the kp randomization range used in training.
Mechanism
A policy transfers only if the plant matches the one it was evaluated on; the pre-flight turns silent hardware drift into a failed check before the robot moves.
Applies when
- the first command after powering a robot on
- after swapping adapters, cables or motors
- a policy that worked last session suddenly behaves differently
“python tools/set_torque.py --check # 12 颗应全对 12/17/11, 有 diff 就 --write … 插任何新 USB 设备后都先跑一次 check_ports.py(IMU 和 CANable 的 USB 身份撞过车) … python tools/calib_stance.py --repeat 3 --write # 重标 offset —— 8/9/10 重新装, 机械零位变了”
RL系统/FOLLOW THIS copy 2.md § WALK / STAND 每次开始前 / 换CAN / 装回后必做两件 Freeze the deployment contract, stamp every export, and let an automated checker catch wiring bugs
contract-freeze-and-checkerFreeze and fingerprint the policy I/O contract; ship contract changes as new versioned profiles that leave old artifacts bit-identical; and extend the automated contract checker with every pipeline change, forcing the new path to execute in the check.
Symptom
Contract-level changes (observation layout, action pipeline) are where silent sim/real divergence is born; two real wiring bugs appeared the one time the action pipeline was extended.
Context
The 215-dim observation contract was frozen ("纪元 3,三机 digest" - an era number plus a digest agreed across three machines); proposals that would break it (e.g. a GRU memory) were rejected on contract grounds. Every exported ONNX is stamped and verified with a manifest (onnx_manifest --stamp / --verify), and deployment refuses mismatched combinations. When C4 added the lateral feed-forward, it went in as a NEW profile (omni_ff) leaving the existing omni profile's behavior bit-identical; the checker (check_contract) was extended to force the feed-forward path to actually execute (cmd_vy=0.13) and promptly caught two genuine bugs: (1) re-clamping with soft_joint_pos_limits after the feed-forward (0.23 rad deviation) instead of reusing the parent's clip; (2) indexing processed actions by asset.joint_names instead of the action term's own contract-ordered _joint_names, which landed the feed-forward on the wrong joints (l_hip_yaw / r_ankle_pitch).
Change
Contract discipline as implemented: frozen dims + digest; manifest stamping and refusal; contract changes only via new versioned profiles; checker updated in the same commit as any pipeline change, with inputs chosen so new code paths are exercised.
Outcome
Both wiring bugs caught before any training or deployment ("两个都是 check_contract 当场抓出来的 —— 这次它值回票价"); old deployments provably unaffected by the new profile.
Mechanism
The contract is the only interface the policy and robot share; freezing plus fingerprinting makes divergence detectable, and an executable checker turns "the contract holds" from a belief into a test - but only if its inputs actually drive the new code path.
Applies when
- modifying the action or observation pipeline of a deployed policy
- exporting policies for hardware
- proposals that would change observation dims or history structure
“契约校验抓到的两个真错误(记账,别再犯):1. 前馈后误用 soft_joint_pos_limits(URDF 限位 ×0.9)重钳 → 0.23 rad 偏差 … 2. 用 asset.joint_names 索引 _processed_actions → 前馈落到 l_hip_yaw/r_ankle_pitch 上 … 两个都是 check_contract 当场抓出来的 —— 这次它值回票价。”
train/C_LADDER_RUN.md § 3j. 契约级改动 / 契约校验抓到的两个真错误 Changing the gait clock silently flipped a hardwired threshold's meaning - write derived constants as expressions
derived-constants-must-track-their-baseBefore changing any base parameter (clock, control rate, scale), enumerate every constant derived from it and every constant that must NOT change; convert derived literals into expressions of the base so the next change cannot silently flip a term's meaning.
Symptom
Slowing the clock 0.40 -> 0.50 s would have silently inverted the feet_air_time threshold's semantics: the 0.25 s threshold was hardwired, so at ct 0.40 the swing window (~0.20 s) sat below it (constant pressure to lengthen strides), while at ct 0.50 the window (~0.25 s) equals it - the term's meaning flips from "push longer" to "neutral" with no code error anywhere.
Context
The clock change audit walked every dependent quantity: most followed automatically (joint_pos_ref / clearance / contact_number cycle_time params, gait_phase observation, deploy/sim2sim/policy_io, export) - wiring confirmed, zero hand edits; the air_time threshold was the one hardwired constant, fixed by preserving the RATIO: 0.25 -> 0.3125 = 0.625 x ct, with the recommendation to commit it as the expression 0.625*ct "一劳永逸" (solved once and forever). The same audit also listed what must NOT follow the clock (50 Hz control rate, physics dt/decimation, 47-dim contract, action_latency absolute seconds, PD/torque limits) - the change's blast radius stated in both directions.
Change
feet_air_time threshold re-expressed as a fraction of cycle_time; auto-following vs must-not-change lists written into the spec for the clock migration.
Outcome
The clock migration (v10, repeated in v11) carried no silent semantic flips; the expression form removed the trap for every future clock change.
Mechanism
Constants derived from a base parameter encode a ratio at their birth; storing the evaluated number severs the dependency, so changing the base leaves stale semantics with no failing test. Expressions preserve the intent; and an explicit both-directions dependency list (follows / must-not-follow) is what makes a base-parameter change reviewable.
Applies when
- changing gait clock, control frequency, or units
- a reward threshold interacts with a phase/window duration
- config audit finds literals that encode ratios
“feet_air_time 阈值 0.25 是写死的,不跟 ct 走——0.40 时摆动窗 ~0.20s<0.25(恒拉长压力),0.50 时摆动窗 ~0.25s≈阈值(语义翻转)。按比例保原压力:0.25 → 0.3125(=0.625×ct;建议直接写成 0.625 * ct 表达式,一劳永逸)。”
train/WALK_V10_SPEC.md § 3. T —— 慢时钟 (训练侧必做一件) Sort external training advice into adopt / already-have / modify / would-trap by recomputing it on your own config
external-advice-audit-against-own-arithmeticNever apply external tuning advice directly: recompute each claim on your own reward table and probe data, classify it adopt / have / modify / trap, and record why - and verify external citations actually exist.
Symptom
External AI/literature advice for the omni ladder arrived plausible-sounding but was written without knowledge of this robot's actual reward table, contract, and history; following it blindly would have broken single-variable discipline and, in one case, made sidewalk unlearnable.
Context
Before the C ladder, every external suggestion was audited: 3 adopted (ellipsoid command sampling; staged wz bands; command-switch acceptance), 3 already present (unified reward; frame history - the frozen 168-dim 5-frame window; per-100-iter acceptance), 2 modified (stand share kept at 20% to avoid a second variable; back share NOT raised because the probe showed backward works untrained 20/20@67%, so oversampling would only crowd out forward), and 1 flagged as a trap: "start vy very small (0.06-0.15)" - on THIS reward table vy was only an L2 tax, so ignoring a vy=0.06 command costs 0.4% of the vx tracking scale, 28-180x cheaper than ignoring forward, with quadratic shrinkage making small commands weaker still. A separate retrieval-reliability note: two search agents returned fabricated verbatim quotes from arXiv PDFs (2 papers, verified fake and discarded); only HTML/abstract/source-verifiable material was used.
Change
Advice classified only after recomputing each claim with local numbers; the "start small" trap was replaced by adding a gated lateral tracking term (the ladder's only true reward surgery) instead of shrinking the command.
Outcome
The adopted items (ellipsoid modes, staged wz, transition acceptance) entered the ladder; the trap was avoided; one external factual error (calling s1g the mainline start - it was falsified 0/20) was caught. Later, one initially-dismissed item (sigma=0.15 too narrow) turned out right for a different reason than claimed - see cycle-average-tracking-for-gait-quantities.
Mechanism
External advice encodes the advisor's reward table and robot, not yours; the transfer-validity test is whether the claim survives recomputation under your own arithmetic (reward margins, probe baselines, contract freeze). Items that survive become experiments; items that don't become documented traps.
Applies when
- incorporating LLM or literature advice into a training plan
- advice conflicts with locally measured baselines
- an external claim depends on reward-table details the advisor cannot know
“其建议 C4「先很小,vy = ±0.06~0.15」—— 在我们这张奖励表下会让侧走学不起来 … 忽略侧走比忽略前进便宜 28~180 倍,且指令越小激励越弱(平方缩放)—— "先很小"在稳定性上对、在梯度上正好把信号缩没了。”
train/C_LADDER_RUN.md § 1. 外部 AI 训练建议的评估(采纳 / 已有 / 要改 / 会踩坑) Removing a hand trim re-exposed the plant offset it had been silently compensating - and a slope scan told bias from sensitivity
hand-trims-hide-plant-offsetsTreat hand-tuned trims as undocumented plant measurements: before deleting one, find what it compensates and re-house that knowledge in the model or the reward budget; diagnose posture errors with a sensitivity sweep to distinguish constant bias from gain problems.
Symptom
After switching from the old hand-trimmed default to the clean geometric zero, the retrained stand policy's only regression was torso lean: 1.8 deg -> 4.1 deg backward.
Context
The old default's ankle-pitch trim (-0.0489/+0.0628) had been pre-compensating a fore-aft COM mismatch; removing the trim removed the hidden compensation, and the posture reward alone was too weak to win it back. A COM sensitivity scan settled what kind of problem this was: sweeping base COM offset -50 to +50 mm gave nearly identical slopes for old and new policies (~0.026 deg/mm) - "不是质心敏感度问题, 是恒定偏置" (not a sensitivity problem, a constant bias). Fix landed in stand_v1b: posture corrected to +0.24 deg while keeping symmetry (<=0.1 deg) and low effort (0.259), disturbance rejection better than both predecessors. Model credibility was checked the honest way: v0's sim prediction at the real COM position (-22 mm) was -2.31 deg lean vs real measured 2.2-3.1 deg - "预测精准命中" - which is what licensed trusting v1b's -0.52 deg prediction. (Side flag from the same file: a sign convention had been documented wrongly in early comments - gravity_base[0] > 0 is forward lean.)
Change
Trims retired in favor of explicit modeling: symmetric geometric default plus a posture-reward budget sized to carry the real COM offset; the offset itself known (real COM ~22 mm behind model).
Outcome
stand_v1b passed acceptance as the standing lineage's final version; the walk-line requirement "加大躯干姿态惩罚权重" was upgraded from suggestion to mandatory, since walking amplifies what standing tolerates (real walk_v1 hit 26 deg lean vs sim 7.4).
Mechanism
Hand trims are plant knowledge stored in the wrong place - invisible, asymmetric, and stale after recalibration; removing them re-exposes the raw plant error. A sensitivity sweep separates the two possible diagnoses (slope change = control problem; parallel offset = constant plant bias), each with a different fix.
Applies when
- cleaning up hand-tuned offsets/trims in defaults or calibration
- a posture bias appears after a default or calibration change
- deciding whether a lean is a COM-sensitivity or constant-offset issue
“两者斜率几乎相同(≈0.026°/mm),v1 只是整体多后仰约 2.4° —— 不是质心敏感度问题,是恒定偏置。成因:旧 default 的踝俯仰 trim(−0.0489/+0.0628)本就预补偿了前后质心偏差,换成零位 default 后这份补偿没了 … v0 在真机质心处(−22 mm)的 sim 预测为 −2.31° 后仰,真机实测 2.2~3.1° 后仰 —— 预测精准命中。”
train/RETRAIN_v2.md § 4b. stand_v1 独立验证结果 / 4c. stand_v1b 验收结果 Compare the achieved reward to the computed ignore-floor to tell "never learned" from "learned but unprofitable"
ignore-floor-diagnosisFor any skill that trains flat, compute the reward the null policy would earn on that term; achieved==floor means the behavior never paid out (find why: exploration, reward observability, or feasibility) - do not tune weights first.
Symptom
C4 sidewalk failed on both arms; the question was whether the policy had found sidewalk and rejected it as unprofitable, or never found it at all - two diagnoses with opposite fixes.
Context
The theoretical value of the sidewalk tracking term for a policy that completely ignores the command was computable from the command distribution: 0.189. Trained final values landed at 0.187 (arm A) and 0.204 (arm B) - sitting exactly on the ignore-floor - while the honest balance at the optimum actually favored sidewalking (net +0.88/step inside the side bucket). Later the same arithmetic closed the whole saga: for the true reward landscape, doing real sidewalk scored 0.153 vs 0.944 for ignoring - the policy's refusal "是理性最优,不是探索失败" (rational optimum, not exploration failure) under one hypothesis, and under the final measurement-corrected account the policy had "每一次都在 做理性选择" (made the rational choice every time).
Change
Diagnostic rule adopted: compute the ignore-floor for the new term; if the achieved value sits on it, the behavior was never expressed in useful volume (or the reward cannot distinguish it - check both); if the achieved value is above floor but the behavior is absent at deployment, the policy sampled it and priced it out - then the reward balance, not exploration, is the lever.
Outcome
Correctly identified that PPO had not merely under-valued sidewalk; each subsequent hypothesis (waveform sign, regularization cage, exploration form, reward kernel) was tested against this floor arithmetic, which kept the search honest through three reversals.
Mechanism
Every reward term has a computable value under the null behavior; the achieved-vs-floor gap is a one-number audit of whether the optimizer ever monetized the target behavior. It converts "training failed" into one of two mechanistically distinct states with different fixes.
Applies when
- a new skill's tracking reward plateaus early
- deciding between exploration fixes and reward-weight fixes
- post-mortem of a failed curriculum rung
“track_lin_vel_y_exp 训练终值恰好坐在「完全无视指令」的底分上(A 0.187 / B 0.204,理论值 0.189),而终点 balance 明明有利(side 桶内净 +0.88/步)。不是学会了不划算,是根本没学到。”
train/C_LADDER_RUN.md § 3e. 为什么首战 FAIL Before resuming a checkpoint, diff the current cfg against what the checkpoint was trained with
resume-state-dr-audit"One variable per rung" counts variables against what the checkpoint actually experienced: audit the checkpoint's logged training config and align every unintended difference before resuming.
Symptom
Two consecutive rungs (C1 back-mode, C2' forward-turn) failed from the same root with the same full-regression signature despite adding different new modes - so the mode was not the cause.
Context
Both runs resumed s1e-500 with the then-current cfg, which carried PD band (0.8,1.2) plus three DR events (base_com, joint_friction, push_robot) accumulated by later lineages. Verified on the training machine from the source of truth (the run's logged params/env.yaml): s1e-500's actual training state was PD +/-10% (0.9,1.1) and all three DR events None. Resuming it under the new cfg meant eating 4 new plant variables plus a new mode at once - the intended "1 variable" was actually 5. A worse variant (c1_redo from s2e_pd-1400) added push +/-0.3 to a root that had never seen it: near-total collapse within +100 iters.
Change
C2 aligned the cfg to the checkpoint's training state before resuming (PD back to (0.9,1.1), three DR events off) - making the new mode the only true variable. Permanent rule recorded: compare the checkpoint's training-time DR with the current cfg before any resume.
Outcome
C2 trained successfully from the same root that had "failed" twice (wz 20/20 with genuine sign-antisymmetric response by iter 700-800); the A/B falsification ("两个不同模式同签名崩") plus the env.yaml verification closed the attribution.
Mechanism
A resumed policy is instantly evaluated (and its value function trained) under whatever plant distribution the cfg specifies; every DR term the checkpoint never adapted to is a distribution shift applied on day one, compounding with the intended change. Single-variable discipline is therefore a property of (cfg diff) x (checkpoint history), not of the cfg diff alone.
Applies when
- resuming or forking any checkpoint under an evolved config
- a resumed run degrades broadly within the first few hundred iterations
- two different changes from the same root fail with the same signature
“A/B 定谳:两个不同模式同签名崩 → 病因不是模式,是「从 s1e-500 续训」。… s1e-500 训练态 = kp/kd ±10% (0.9,1.1),base_com / joint_friction / push_robot 全 None;而 cfg 里带着 (0.8,1.2) + … 三个 DR —— 从它续训等于一次吃 4 个新 plant 变量 + 新模式 … 永久教训:续训前必须比对 checkpoint 的训练态 DR 与现行 cfg。单变量纪律不只看「我改了什么」,还要看「checkpoint 见过什么」。”
train/C_LADDER_RUN.md § 3b. 这不是重复实验 —— 前两次的病根已定位并修掉 Two machines, one configuration - every gain, offset and torque limit changes only in robot.yaml, whoever edits pushes at once, both checkouts show the same commit before the robot moves, and a pulled policy file is size-checked and synced before power-off
two-machine-config-disciplineTreat the robot's configuration as a versioned artifact with one source of truth, push every change immediately, verify identical commits on every machine before a hardware session, keep hardware limits in the repo and the firmware in sync in both directions, and verify transferred model files (size, digest) before running them.
Symptom
The robot's onboard computer runs the bridge and deploy scripts from its own checkout while training and analysis happen on other machines; a hot fix left on one side, or a half-written file, silently makes the robot run something other than what was evaluated.
Context
The operator runbook's "wall version" of the two-machine discipline: configuration changes only in robot.yaml (calibration offset/sign, gains, torque limits), committed and pushed from the Mac, pulled on the robot, bridge restarted; code is not edited on the robot, and if it is, it is committed and pushed on the spot - nothing unpushed overnight; 30 seconds before every real-robot session both checkouts must show a clean status and the same last commit hash; changing tau_max requires writing the motor's limit_torque too (and the reverse); re-zeroed motors require re-measuring offsets. The recovery line added: after pulling on the robot, check the ONNX is not zero bytes (a lesson from a corruption incident on 08-12) and sync before cutting power; the recovery and main lines are separate worktrees, each pulled with --ff-only.
Change
Operating rules, pinned on the wall and repeated in the hanging checklists ("git pull, both machines on the same commit").
Outcome
The sources record the rules and the incident that produced the size check; they do not record a count of sessions the rules caught.
Mechanism
A policy is evaluated against one configuration; any divergence between the machines, or a truncated file, turns a hardware result into a result about an unknown configuration.
Applies when
- a robot's onboard computer and a workstation both hold the configuration
- someone hot-fixes code or gains on the robot
- model files are copied or pulled to the robot before a session
“改配置只改 robot.yaml(标定 offset/sign、增益、限扭全在里面)→ Mac git commit + push → NX git pull → 重启桥。 … 谁改完谁立刻推,永远不留未推送的改动过夜。 … 每次上真机前 30 秒检查:两边 git status 干净、git log -1 哈希一致。 … 铁律不变:改 tau_max 必须同步写电机 limit_torque(反之亦然);电机重新标零后 offset 必须重测回填 yaml。”
RL系统/FOLLOW THIS copy 2.md § ② 双机维护纪律(贴墙版) Three hardware accounts locked the run design point - and the knee's real speed ceiling is tau_limit/kd, not the firmware limit
feasibility-accounts-lock-design-pointBefore opening a dynamic-gait training line, compute the full account set - tau_limit/kd effective speed ceilings, joint ROM under the intended reference geometry, and thermal RMS at the duty cycle - and let the accounts lock the design point; move only to pre-registered in-table alternates, re-running the accounts first.
Symptom
The run line was believed to require a firmware raise of the RS06 speed limit (10 rad/s) as a hard precondition, and the feasibility script's motor-envelope scan had marked 80/100 mm foot-lift cells "physically feasible".
Context
Three added accounts re-decided everything. (1) Damping tax: in MIT mode tau = kp*(q_des-q) - kd*qd, so sustained rotation is capped at tau_limit/kd = 12/1.5 = 8 rad/s - below the firmware's 10; at peak speeds 6.7-7.9 rad/s the damping term alone eats 10.1-11.9 N*m (84-99% of the torque limit). "提固件 limit_spd 越不过这道税 —— 它是 kd 与限扭的比,不是固件旋钮." (2) Joint ROM: the feasibility script had checked motor envelopes but NOT joint range - the ankle-pitch ROM caps 1:2:1 leg-shortening lift at 62 mm (soft) / 77 mm (hard), so the 80/100 mm "feasible" cells were voided; also firmware-independent. (3) Ankle thermal: duty 0.40 puts ankle RMS at 87% of continuous rating (0.35 -> 93%); long-period big-stride cells hit both ankle torque peak and heat. Verdict: firmware raise DEQUEUED (50 mm design point needs knee 6.7-7.3 < the 8 rad/s effective ceiling < firmware 10); vel_limit stays 10 so sim == robot. The three accounts uniquely lock the design point - 50 mm lift / T 0.60 s / duty 0.40 - "三笔账 唯一锁定,不是调参空间", with pre-registered alternates allowed only inside the table and only after re-running the accounts.
Change
Design point frozen from accounts; hardware precondition reversed by arithmetic rather than by test; reference amplitude (0.84 rad = FK inverse of 50 mm) derived, per-joint action scales sized to the required travel (knee 0.9, hip_pitch 0.6, ankle deliberately NOT amplified - hard limit is adjacent).
Outcome
A firmware work item left the critical path; an infeasible region of the design space was closed before any training; the remaining risk (knee tracking lag from the damping tax) was pre-registered with its own criterion and in-table fallback (duty 0.35) - "这不是'奖励没调好', 是 plant 账".
Mechanism
PD actuators in MIT mode pay kd*velocity out of the same torque budget that tracks position, so the effective speed ceiling is a ratio of configuration constants, invisible to firmware settings; and feasibility is the intersection of ALL constraint families (torque envelope, joint ROM, thermal RMS) - a scan that omits one family certifies impossible cells.
Applies when
- planning running/jumping or any high-rate gait on PD actuators
- a firmware or hardware upgrade is assumed as a training precondition
- a feasibility scan covers motor limits but not ROM or heat
“膝的有效速度顶 = τ_limit/kd = 12/1.5 = 8 rad/s,不是固件的 10。… 提固件 limit_spd 越不过这道税 —— 它是 kd 与限扭的比,不是固件旋钮。… 可行性脚本只查了电机包络没查关节 ROM —— 其 80/100mm 的"物理可行"格作废。… 判决:RS06 提固件对 run v0 不是前置,出队”
train/RUN_V0_SPEC.md § 1. 硬件账判决 / 2. 步态设计点 A constant-value plant rung passed every binary gate with record scores - and shipped 60% thinner posture margins that hardware exposed
constant-value-dr-overfits-marginRandomize deployment-critical axes over a narrow band spanning the measured real support - never a single value, never a fictitious tail - and report graded margin quantities (tilt margin) next to binary gates, because saturated gates rank thin-margin and thick-margin policies identically.
Symptom
s2_lag1 (trained at constant 1-frame latency) posted the strongest sim gate sheet in history (20/20 everywhere) yet was unstable on hardware, while s1e (trained across the full 0-3 frame band) was the every-run-stable SOTA at the same power.
Context
The sim autopsy (new --delay-jitter harness modeling the BusWorker's time-varying phase drift): 18 runs across constant and time-varying delays ALL survived - time variation alone does not kill - but the tilt-margin ordering reproduced hardware exactly: s1e 7.7-9.1 deg (thickest) < s2_lag1 10.7-15.0 < s1c 16.2-18.2. Attribution: constant-value training permits precise specialization to that one value; s1e's band diversity forced cross-value robustness - "恒定 1 帧训练 vs s1e 的 0~3 帧全带——分布多样性逼出跨值鲁棒,恒定值允许精确 特化" - so the constant-rung policy's margins were ~60% thinner, fine in sim's clean world, pushed over the line by real-world disturbances. Tool lesson booked: "存活门二值饱和后掩盖裕度差" - binary survival gates saturate and hide margin differences; graded margin columns (tilt-max) belong in the report. The synthesis with the opposite failure (wide tails cause drag-glide): the proposed resolution was a NARROW uniform band (0.02, 0.04) covering exactly the real 1-2 ticks - diversity inside the measured support, no tail, no single point. s1e's root selection later leaned on the same property: its full-band latency training "预装" the delay rungs and delivered "全工况稳定裕度" that survived power derating.
Change
DR-on-an-axis design refined to a three-way distinction: no wide fictitious tails (drag), no single constant values (thin margins), but a narrow band spanning the measured real support; acceptance reports gained graded margin columns alongside binary gates.
Outcome
The tilt-margin column entered the standard report; the s1e root (band-trained) carried the C ladder while the constant-value branch was archived with its three contributions credited.
Mechanism
Robustness margins are shaped by the diversity of the training distribution, not just its support: a point-mass distribution lets the optimizer trade margin for on-point performance, while a band forces solutions that keep margin across the band - and binary survival metrics cannot see the difference until the margin is spent on hardware.
Conflicts
The narrow-band (0.02,0.04) resolution was a pending recommendation ("裁决建议(待用户)") at the time of writing; the lineage instead moved root to s1e whose full-band training predated the staged ladder - the deterministic-staging card and this card record the two failure modes the final design must avoid simultaneously.
Applies when
- a rung trained at a fixed plant value aces sim but wobbles on hardware
- binary acceptance gates are all saturated across candidates
- choosing between constant, banded, and wide DR on one axis
“18 跑全活,时变性单独不足以击杀;但 tilt_max 裕度排序完整复现真机:s1e 7.7~9.1°(最厚)< s2_lag1 10.7~15.0 … 恒定 1 帧训练 vs s1e 的 0~3 帧全带——分布多样性逼出跨值鲁棒,恒定值允许精确特化 … 存活门二值饱和后掩盖裕度差(s2_lag1 sim 门 20/20 史上最强却真机不稳)”
train/README.md § s2_lag1 真机不稳 × s1e 稳的 sim 对拍(2026-08-07,时变延迟实验) Continuing a converged policy on a change that carried no new gradient drifted its transfer from 100/98% to 80/28% over 3,000 iterations while every Isaac gate stayed perfect - scan every checkpoint on the second simulator's friction axis
converged-continuation-is-poisonBefore continuing a converged policy, check that the change creates a live gradient; if it does not, cap the budget at a few hundred iterations, and in every continuation scan each checkpoint on the second simulator's transfer axis (for example low friction) - trainer-side gates can stay perfect while transfer decays.
Symptom
V2.7-A (swap the flat_feet term for a compensated version, continue from v2_6c) finished with the line's best Isaac score (100%) and a MuJoCo transfer collapse: mu 1.0 98 -> 80%, mu 0.4 98 -> 28%; the stance it was meant to widen had not moved.
Context
The new term's calibration run showed a near-zero tax from the start: the policy already satisfied it, so the reward landscape offered nothing new. A checkpoint scan on MuJoCo mu {1.0, 0.4} located the damage: +100 iterations 100/98% (better than the baseline), then 86/54, 60/38, 80/28 - monotonic decay with training length, while entropy and action noise rose (7.77 -> 8.18, 0.588 -> 0.612): drift, not sharpening.
Change
Rule written in: with no new gradient, a continuation budget is short (at most a few hundred iterations) and the MuJoCo transfer axis enters every checkpoint scan. The next rung (V2.7b, a live stance-width gradient) was budgeted at 1,000 iterations with mu {1.0, 0.4} scans every 100 and a stop-on-signal rule.
Outcome
V2.7b kept transfer at the same depth (mu 1.0 98% / mu 0.4 92% at +1,000, where A had already rotted to 86/54) and at +3,000 (100/96%): a live gradient preserved transfer. V2.8 then broke that pattern (mu 0.4 2%): the gradient must also be compatible with the policy's existing form.
Mechanism
On a converged reward landscape PPO keeps updating without a signal to follow, and the random walk is pulled toward whatever the training plant rewards idiosyncratically - invisible in the trainer's own gates.
Conflicts
The drift mechanism is the spec's reading of one decay series plus one contrasting run; V2.8 is recorded as an exception to "live gradient keeps transfer".
Applies when
- fine-tuning a converged policy with a small reward change
- a continuation run's trainer-side metrics improve while real or cross-sim results worsen
- choosing which checkpoint of a continuation to ship
“**checkpoint 扫定死因**(μ1.0/μ0.4):**29500(+100 iter)= 100/98%** (优于基线!)→ 30400 = 86/54 → 31400 = 60/38 → 32398 = 80/28 —— **迁移随续训长度单调衰减**。 … **教训入库:收敛均衡上的长续训是毒药 —— 无新梯度时 续训预算须短(≲数百 iter),且 MuJoCo 迁移轴必须进 checkpoint 扫描。**”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §43 结果:V2.7-A 判 FAIL —— 换刀本身无罪,毒在续训预算 Close a question with an audit, then freeze the wording - later symptoms may not reopen it without new hard evidence
frozen-verdicts-semantic-boundariesWhen an audit closes a hardware-vs-policy question, record the closing evidence, freeze a citable wording for future recurrences, and set the reopening bar explicitly; separate robustness perturbations from plant-truth questions so a DR rung's failure can never silently reopen a closed measurement.
Symptom
Recurring directional bias on the robot kept re-suggesting "maybe the hardware/COM/mechanics are asymmetric", threatening to re-litigate questions that audits had already closed - burning attention each time a descendant policy leaned or drifted.
Context
Two boundary decisions were written as permanent: (1) semantic separation - "S2④ COM ±20mm = 纯鲁棒性扰动,不再承担「解释真机后仰」任务" - if the COM-DR rung degrades, the ONLY allowed conclusion is "policy insufficiently robust to COM uncertainty"; reopening "is the CAD COM wrong" is forbidden because the mass audit was completed and closed (@63f9212). (2) a frozen wording for chirality, to be quoted verbatim whenever left/right bias appears in later rungs: observed directional bias = policy-level spontaneous symmetry breaking; plant asymmetry = no supporting evidence after the mass + model symmetry audit; mitigation candidate pi_sym queued, not blocking. The evidential basis was quantitative: the root policy was perfectly symmetric under +/-6 N*s pushes (40/40) while descendants broke (17/40, 13/40) - "手性是 S2 训练中获得的, 根没有; 机械侧已双 PASS 关案, 不重开".
Change
Closed questions carry (a) the audit commit that closed them, (b) a frozen citable wording for recurrences, and (c) an explicit evidence bar for reopening ("无新硬证据不得重开").
Outcome
Later chirality observations (C2's 15 pp turn gap, hip_roll drift bias) were handled as policy-lineage properties with policy-side mitigations, without a single hardware re-audit cycle.
Mechanism
Symptom classes recur under different guises; without a frozen verdict each recurrence re-runs the same expensive investigation and risks a different (worse-informed) conclusion. Freezing verdict plus wording converts recurring symptoms into citations, while the evidence bar keeps the closure honest rather than dogmatic - the root/descendant symmetry comparison is what makes "it's the training, not the machine" checkable at any time.
Applies when
- a recurring symptom keeps suggesting an already-audited hardware cause
- writing conclusions for a completed calibration/audit
- a DR rung's degradation invites re-measuring the plant
“若 S2④ 退化,结论只能是「当前 policy 对 COM 不确定性不够鲁棒」,不得重开「CAD COM 是不是错了」… 手性冻结表述 … Plant asymmetry: no supporting evidence after mass + model symmetry audit … 无新硬证据不得重开机械不对称”
train/OMNI_V0_SPEC.md § 4. 语义分界与手性冻结表述(2026-08-07 用户定,永久) A policy's gain profile is part of its contract - the one-leg policy needs per-joint gains the default profile lacks, and the manifest refused an evaluation under the default once; the recovery contract's beta was never stamped, a known gap not to repeat
gain-profile-belongs-in-the-stampStamp everything that defines the closed loop a policy was trained in - gains included - into its manifest, and make every consumer refuse a mismatch; a profile field that is not in the stamp is a silent misconfiguration waiting for an operator to forget a flag.
Symptom
A policy trained with hip_roll kp 80 and ankle_roll kp 60 behaves differently, or falls, under the default kp 20/12 profile - and the gain profile is a command-line flag an operator can forget.
Context
The one-leg line added a gain_profile field to the contract so the stamped manifest carries it; the spec's deployment note says the manifest guard blocks rl_default and that it had already bitten once in simulation (an evaluation run without the one-leg profile). The same spec states the general rule - any new profile field must be synced into the manifest builder - and names the counter-example: the recovery line's beta was never put into the manifest. The recovery line itself had decided that its anchored authority is computed from the base rl gains and written into the contract so it cannot drift with the gain flag, and that the older kp x 0.9 profile chosen in the V0 era does not match the beta contract and must not be used.
Change
Gain profile as a contract field checked at load; per-contract gain choices written into the run sheets.
Outcome
Evaluations and hardware runs of the one-leg policy run under rl_oneleg or are refused; the recovery beta gap stayed recorded as known.
Mechanism
A policy is trained against a closed loop whose gains are part of the plant; running it under other gains is an out-of-distribution plant, exactly like a wrong observation scale.
Applies when
- a skill introduces per-joint or skill-specific gains
- deployment gains are chosen by a command-line flag
- adding any new field to a policy profile
“增益档 `--profile rl_oneleg` 必须给 —— manifest 防线会拦 `rl_default`(sim 已咬合一次) … (recovery 的 β 未进 manifest 是已知缺口,不再复制)”
git:Lucen V2@origin/oneleg-line:train/ONELEG_V0_SPEC.md § §9b AGX 真机手顺 要点 / §3 契约 No parameter tuning on the floor - a failing config retries once, then it is out; anomalies go back to sim
no-field-tuning-protocolHardware time is for executing and measuring the pre-registered matrix, never for tuning: failing configs get one retry then elimination, anomalies get recorded and reproduced in sim, and contract-check bypass flags stay unused.
Symptom
Hardware sessions create pressure to fix problems live - nudge a gain, tweak a scale - which destroys attribution and risks the robot.
Context
The anomaly-handling section of the acceptance sheet is three fixed plays: (1) falls at start -> retry once at the same settings; falls again -> that configuration is eliminated, "不现场调参" (no on-site parameter tuning); (2) limit cycle or motor screech -> stop immediately, record the gain level and the joint, reproduce in sim before any discussion; (3) systematic disagreement with sim -> record it as a finding (hardware outranks sim) rather than adjusting anything to force agreement. Related guardrails elsewhere in the sheet: never pass --allow-unstamped / --allow-plant-drift to bypass manifest checks - if it errors, something real is wrong, stop and look.
Change
Field sessions restricted to executing the pre-written matrix; every fix path routed through sim reproduction and the normal config/rung process.
Outcome
Sessions stayed interpretable (each run matched a documented config) and safety overrides never became habit; anomalies arrived back in sim as reproducible cases instead of half-remembered floor stories.
Mechanism
Field-tuned values are measured under adrenaline on one floor with no logging or baselines - they contaminate the config lineage and are unattributable afterwards; and every bypass flag that skips a contract check converts a designed safety property into an operator promise.
Applies when
- a config fails or oscillates during a hardware session
- someone reaches for a live gain tweak or a bypass flag
- writing the anomaly-handling section of a deployment runbook
“起步即摔 → 换档重试一次, 仍摔则该档出局, 不现场调参。出现极限环/啸叫 → 立刻停, 记录档位与关节, 回 sim 复现再议。… 不要给 --allow-unstamped / --allow-plant-drift —— 三枚 ONNX 都已盖章 … 真要报错说明有别的问题, 停下来看。”
train/REAL_RUN_S2.md § 4. 异常处置 Late training leaned on sampling noise as a stability crutch - deterministic play collapsed while training metrics stayed green
noise-crutch-deterministic-collapseEvaluate the deterministic policy in an external harness on a fixed cadence during training (not just at the end), select checkpoints on that curve, and treat a collapsing noise_std with rising training reward as a warning that noise is load-bearing.
Symptom
omni_s1's final checkpoint (model_5999) fell at 4 s even in Isaac's OWN deterministic play, while checkpoints from iter 1700-4000 were fine - and no training metric flagged anything. Policy noise_std had collapsed to 0.045 by iter ~990 (final 0.033).
Context
Diagnosis: the policy had learned to use its exploration noise as a dither/stabilizer - "策略把采样噪声当稳定拐杆,训练指标看不见" (the training metrics cannot see it, because training always runs with noise on). Countermeasures: entropy_coef 0.005 -> 0.01 to slow the std collapse, and - the structural fix - an in-training smoke loop (watch_ckpt.py): every 500 iters, export ONNX directly, run 3-seed MuJoCo evaluation, log CSV/TensorBoard curves plus three-view videos. The doctrine line was written in bold: "训练指标全绿不再是发育健康的 证据,冒烟曲线才是" - green training metrics are no longer evidence of healthy development; the smoke curve is. The follow-up run s1b showed the drift metric follow a U-shape (73 -> 8.6 at iter 3500 -> 76), making checkpoint selection BY the smoke curve (early stop at 3500) the shipping mechanism, with terminal re-degradation booked as known and unresolved.
Change
entropy floor raised; watch_ckpt smoke loop instituted as standing infrastructure; checkpoint selection moved from "last iteration" to "best point on the deterministic smoke curve".
Outcome
s1b shipped from iter 3500 (the U-bottom) instead of a degraded terminus; every later lineage (s1c/s1e, the C ladder's --every 100 loops) inherited the watcher as the standard guardrail.
Mechanism
PPO evaluates and improves the stochastic policy; if noise itself stabilizes the gait (dither smoothing a marginal limit cycle), the deterministic mean policy is a different, worse controller that training never measures. External deterministic evaluation on an independent simulator is the only readout of what will actually be deployed.
Applies when
- final checkpoints underperform mid-training ones
- noise_std collapses early while training reward climbs
- deciding which checkpoint to export and ship
“训练后期确定性脆化——noise_std iter~990 收到 0.045(终 0.033),model_5999 连 Isaac 确定性 play 都 4 s 摔(1700~4000 正常):策略把采样噪声当稳定拐杖,训练指标看不见。对策:entropy_coef 0.005→0.01 + train/watch_ckpt.py 训练中冒烟曲线 … 训练指标全绿不再是发育健康的证据,冒烟曲线才是。”
train/OMNI_V0_SPEC.md § 3. S1.1 修订记录 ② Write each config's expected hardware signature before the session - and if reality disagrees, change the books, not the conclusion
preregistered-real-expectationsBefore hardware runs, write per-config expected signatures and the disagreement rule (hardware outranks sim; discrepancies get recorded, not reconciled); validate the harness by checking it reproduces at least one known real behavior.
Symptom
Hardware impressions are easily narrated after the fact; without written expectations, any real-robot outcome can be made to "match" the sim story.
Context
The S2 acceptance sheet carried a section titled "sim 侧预注册预期 (事后核对, 不许事后改)" - per-configuration behavioral signatures written before the session: s1e@0.8 the disturbance king (push 159/160, zero chirality, all-mu 20/20) at the cost of speed gates 0/20 and zero-command wander ~0.98 m with -29.5 deg/20 s rotation; fric-3000 "walks accurately but is easier to push over"; fric-2400 neither. Credibility check included: the sim harness had reproduced the already-recorded real behavior (pace in place + right drift + net rotation -30 deg/20 s), which "提高本单全部预期的可信度". The anomaly clause fixed the epistemics in advance: if results systematically disagree with sim, "不改结论改账" - don't massage the conclusion, write the discrepancy into the books, and per the earlier zero-warning lesson, hardware wins.
Change
Every hardware session ships with a pre-registered expectation table (signature per config), a baseline-match credibility check, and a written precedence rule for disagreement.
Outcome
The A/B session became falsifiable: agreement confirms the proxy, disagreement is booked as a proxy-bias finding rather than argued away.
Mechanism
Pre-registration converts qualitative hardware sessions into tests of the sim-to-real mapping itself; a reproduced known behavior calibrates trust in the remaining predictions; and fixing "who wins on disagreement" beforehand prevents authority from drifting to whichever source flatters the plan.
Applies when
- planning any hardware acceptance or A/B session
- the sim harness's credibility in this regime is unestablished
- post-session write-ups tempt narrative fitting
“⚠️ sim 复现了真机已记录的「原地踏步 + 右漂 + 净旋 −30°/20s」—— harness 与真机行为对得上, 提高本单全部预期的可信度。… 结果与 sim 系统性不符 → 不改结论改账: 写进 README 该节, 按 「Isaac 指标三次零预警」的教训, 以真机为准。”
train/REAL_RUN_S2.md § 2. sim 侧预注册预期 (事后核对, 不许事后改) / 4. 异常处置 Push DR helped one lineage and hurt another at the same dose - robustness budget is conserved and gets borrowed, not created
push-dr-conditional-budget-conservationBefore opening a disturbance-DR rung, measure whether the untrained policy already meets the spec; if training it anyway, expect the benefit to be conditional on the lineage's existing DR load, grade the intensity, and audit retained margins - budget spent elsewhere will be borrowed back.
Symptom
The push rung's outcome flipped with the lineage: direct +/-0.6 m/s push failed outright on first attempt (base walking collapsed - kd1.2 scan 0/3 from iter 3300, sim2sim self-falls with pushes OFF - no PASS point existed); staged +/-0.3 then gave the narrow-kd single-working-point lineage real gains (push survival 1/5 -> 4/5) while the SAME dose made the dual-working-point balanced-band lineage WORSE (20-seed survival 18 -> 12/20 plus across-the-board push regression).
Context
The four-ladder verdict ("四梯定案", s2e/s2f at both intensities) named the pattern: "push DR 收益条件性" - the benefit is conditional on how much robustness budget the lineage has already spent. The law candidate: "DR 总预算守恒, 平衡带鲁棒性从抗扰余量借" - total DR budget is conserved; a lineage already covering a wide plant band pays for push tolerance out of its disturbance margin. Both S2 ladders therefore closed at the friction rung, with the decisive numerator: untrained push tolerance already met the 4-6 N*s requirement, so the rung was not needed at all ("⑥ push 不训(收益条件性,免训 ±0.6 已达 标)"). The same accounting later justified the C-before-S2 ordering ("push/μ 两轮已实证 DR 预算有限且会被重分配") and trimmed the second S2 pass to three rungs.
Change
Push removed from the standing ladder; graded intensity retained as the method IF a lineage ever needs push training; "does the untrained policy already meet the disturbance spec" instituted as the first check before opening any disturbance rung.
Outcome
Two rungs (push, ground mu) deleted from the second S2 pass on measured grounds; the ladder's real yield was re-stated honestly as precision, not robustness (speed gate 0 -> 20/20, zero-command drift 0.98 -> 0.06 m, but push 159 -> 125/160).
Mechanism
A fixed-capacity policy allocates representation and margin across the training distribution; adding a disturbance axis to a lineage that already spans a wide plant family forces reallocation - the new tolerance is bought with existing margins. Lineages with narrow plant coverage have free budget, so the identical DR dose lands as gain. Benefit is a property of (dose x lineage state), never of the dose alone.
Applies when
- proposing push/perturbation training on a hardened lineage
- the same DR rung helped one lineage and hurt another
- accounting where a ladder's robustness gains actually came from
“push DR 收益条件性 —— s2e⑥a (单工作点血统 kd 窄带) ±0.3 得抗推 1/5→4/5; s2f⑥ (双工作点平衡带血统) 同档反而 20-seed 存活 18→12/20 且抗推全面倒退。规律候选: DR 总预算守恒, 平衡带鲁棒性从抗扰余量借。两阶梯均以 ⑤ 摩擦级收官 … 抗推 4~6 N·s 免训已达标。”
train/OMNI_V0_SPEC.md § 4. ⑥ push 四梯定案 (2026-08-07) Three same-shaped judging errors - task metrics (survival, tracking, displacement) cannot stand in for posture metrics
task-metrics-vs-posture-metricsKeep validated posture-class rows (tilt, per-joint L/R asymmetry, temperature) in every acceptance battery alongside task rows; when operator feel contradicts the gates, suspect the metric class before the operator - and never build a new skill on what is actually an asymmetry defect.
Symptom
The C2 product judged "full pass" on task metrics (A800: turn-gap 7 pp, vx+0.30 19/20) felt WORSE in the operator's hands than the half-pass 700: A800 tilted up to 12.90 deg (700: 6.64), drifted left while standing, showed larger per-joint asymmetries, and ran its hip_rolls 5 degC hotter.
Context
The re-judgment catalogued three same-type metric errors in one campaign: (1) stand judged by SURVIVAL - missed 0.5-1.4 m wandering; (2) stand ranked by DISPLACEMENT - ordering was opposite to real feel (tilt ordering matched); (3) chirality judged by wz-tracking GAP - measured turning symmetry while the robot's actual disease was postural left/right asymmetry, "两个不同的东西,且结论相反". Common pattern named: "我一直用「任务指标」当判据,而真机手感对应的是「姿态 指标」… 任务类指标不能替代它". The fix was already in the data: the per-joint left/right asymmetry table (printed identically by sim2sim and deploy) agreed with hardware in direction on every row - "判据可用、有预测力,我只是没把它写进 PASS 条件". Shipping decision followed the posture read: product reverted to 700 ("又一次「买到 精度、卖掉别的」"), and the C4 root moved to 700 as well, with the sharpest line of the episode: A800's left-drift "like sidewalking" is probably its frontal-plane asymmetry defect, not a capability - "在缺陷上建能力是危险的".
Change
Two posture quantities with demonstrated real-robot predictive power promoted into every PASS battery: tilt-max median and per-joint left/right asymmetry (both sim-computable, deploy-homologous); motor-temperature readout added to session close-out.
Outcome
Deployment flipped to the posture-better checkpoint; the hip_roll temperature table (43-48 degC vs 25-28) confirmed the earlier 90%-of-heat account; the run-line acceptance battery inherited the posture rows from birth ("任务类替代不了姿态类").
Mechanism
Task metrics measure goal attainment under the evaluator's episode definition; posture metrics measure the body state trajectory that operators, motors, and downstream skills actually experience. The two can rank candidates oppositely because task success tolerates postural pathology - so a battery without posture rows is blind to exactly what hardware feel reports first.
Applies when
- hardware feel disagrees with a green acceptance table
- choosing between checkpoints that split task vs posture metrics
- selecting the root for a skill that resembles an existing defect
“共同模式:我一直用「任务指标」(存活 / 跟踪率 / 位移)当判据,而真机手感对应的是「姿态指标」(倾角、逐关节左右不对称)。→ 验收判据里必须有姿态类指标,任务类指标不能替代它。… A800 的「左飘像 side walk」很可能 … 是它更大的额平面不对称的表现 —— 在缺陷上建能力是危险的。”
train/README.md § C2 选点改判 (2026-08-09): 手性判据第三次选错指标 Under continuous 3-axis uniform sampling, pure straight-line walking is a zero-measure event the policy never trained
zero-measure-commands-need-mode-samplingEnumerate the exact command points users will actually issue (straight, stop, in-place turn) and give each explicit probability mass via mode sampling with off-axes pinned to zero - never assume a continuous sampler covers its measure-zero subsets.
Symptom
"The robot drifts even in sim when told to walk straight" persisted across reward tunings - because with commands drawn as vx in [0.15,0.5] x vy ~ U(+/-0.2) x wz ~ U(+/-0.6), the event vy=0 AND wz=0 has probability zero: pure straight-line walking was never sampled even once.
Context
Restart evidence item #3: "纯直行是零测度点 … 'sim 里直行就漂'是分布的 必然,不是 reward 没调好" - the drift metric was legitimately drowned by commanded turning (v11's own comment self-documented this). The structural fix is discrete mode sampling: a custom ModeVelocityCommand that first draws a mode by share (stand/forward/back/turn/side/mixed), then draws values only on that mode's axes with all others pinned to exact zero - which is also what preserves single-variable discipline in the C ladder (native 3-axis uniform "采不出'离散模式桶' … 把 C1~C4 的单变量纪律直接毁掉"). The mixed mode later got an ellipsoid constraint rather than a cube for the same reason in reverse - corner combinations of a cube are unrepresentative extremes.
Change
Command generation moved from independent per-axis uniforms to mode-bucket sampling with pinned-zero off-axes (plus 20% rel_standing); acceptance likewise evaluates per mode.
Outcome
Straight-line behavior became a trained, testable mode instead of a measure-zero hope; the C ladder could add one mode per rung with provable isolation.
Mechanism
A policy optimizes expected reward under the command distribution; events of probability zero contribute nothing to the objective, so exact-zero-command behaviors (straight walk, stand, in-place turn) are only learned if the sampler gives them mass. Product-of-uniforms distributions concentrate mass on mixtures and give none to the pure behaviors users actually command.
Applies when
- a "simple" command (straight, stop) underperforms mixtures in sim
- designing command distributions for velocity-tracking tasks
- a ladder needs per-mode isolation for attribution
“纯直行是零测度点:最终 command 为 vx∈[0.15,0.5] × vy∈U(±0.2) × wz∈U(±0.6) 连续均匀,vy=0∧wz=0 从未被专门采样 —— "sim 里直行就漂"是分布的必然,不是 reward 没调好 … Isaac 原生 UniformVelocityCommand 是三轴各自 uniform,采不出"离散模式桶"”
train/OMNI_V0_SPEC.md § 0. 为什么从零 (3) / 三件前置 (1) A single-signal contact detector lied in both directions - foot height flagged 40% false flight on a walking gait, contact force alone flagged false flight during low-friction slip - so flight became force < 5 N AND sole height > 5 mm
contact-detector-single-signal-liesDefine contact and flight events from two independent signals (force and geometry) in conjunction, validate the detector on a behaviour known not to contain the event before using it as a gate, and match the trainer's threshold when comparing across simulators.
Symptom
The run line needed a flight-fraction gate. The first MuJoCo version, "sole higher than 2 mm", measured 40% flight on a walking policy that never flies. Five weeks later the one-leg gate, using contact force alone, reported support-foot "flight" segments at mu 0.4 for a policy that was not hopping.
Context
During a walking step the toe lifts or the heel strikes with the foot pitched, so the ankle-roll origin rises a few mm while part of the sole still touches - height alone calls that flight. Switching to contact force < 5 N (the same threshold Isaac's contact reward uses) zeroed the false flight on walking. In the one-leg re-test every force-only "flight" segment had a measured sole height of 0.0 mm: the normal force chattered while slip corrections played out on low friction.
Change
Run line: flight = contact force < 5 N ("lift-off must be judged by contact force"). One-leg line (2026-09-16): flight = force < 5 N AND sole height > 5 mm, recorded as the same measurement lesson in the opposite direction; the gate's behavioural meaning was unchanged.
Outcome
With force-based detection the walking policy read 0.0 flight and the run policy's zero flight was confirmed by two plants; with the conjunctive definition the one-leg support-foot gate stopped reporting false hops.
Mechanism
Each signal has its own failure: geometry moves without leaving the ground (foot pitch), and forces drop without leaving the ground (slip chatter); requiring both removes both families of false positives.
Applies when
- writing a flight, lift-off, hop or slip detector for a gate
- a gate reports an event the video does not show
- reusing a detector on a different gait or floor friction
“首版用**足底高度>2mm** 判离地, 在 omni_s1e 走路策略上测出 40% 假腾空 … 改用**接触力 <5N**(与 Isaac feet_contact_number 同源阈值)后 空检归零 (walk 策略 flight_frac 0.0)。**课文: 离地判定必须用接触力, 高度判 会把脚的俯仰当腾空**”
train/README.md § run R1 立项 (2026-08-09): Mac 侧新工具 + 一次空检抓获 After seven patch-generations, freeze the lineage as a regression baseline, fix the structural debts, and retrain from zero
freeze-lineage-fix-structure-restartWhen successive rungs keep trading one symptom for another, ask whether the remaining problems are structural (contracts, latency, sampling, reward-table architecture); if so, freeze the lineage as regression baselines, pay the structural debts, and restart minimal - carrying forward laws and instruments, not weights and weights' patches.
Symptom
The v5-v11 walk lineage had accumulated interacting patches (reward terms, gates, clamps, per-joint scales) faster than it converged on the user's goal; v12's spec itself was superseded before training by an external review's verdict that the remaining problems were structural, not parametric.
Context
The 2026-08-05 status banner records the pivot: the walk profile was rolled back wholesale to v10b parameters, the v5-v11 lineage frozen "只作回归对照" (kept only as regression baselines), and four structural debts were named as prerequisites for a from-zero straight-walk baseline: the action-latency FIFO (fixed with its own test), the ONNX manifest contract, discrete command sampling, and a minimal reward table. The v12 spec - fully designed, partially implemented - was suspended: "本规格挂起,不再按此开训".
Change
Strategy switched from "one more patch generation" to freeze-fix-restart: lineage checkpoints retained as comparison anchors, infrastructure hardened first, then a clean retrain with a minimal reward table (this restart produced the s* generation that later became the real-robot SOTA line).
Outcome
A designed-and-ready training generation was deliberately not run - the review's structural findings outranked sunk design cost; the restart line inherited seven generations of laws (calibrations, gate batteries, falsified fixes) without inheriting their entangled reward table.
Mechanism
Patch lineages accumulate coupled terms whose interactions eventually cost more to reason about than a restart costs to train; the knowledge worth keeping is the laws and instruments (measured plant values, calibrated gates, falsified directions), not the entangled weights. A restart on hardened structure converts the lineage's lessons into a clean initial design instead of another delta.
Applies when
- repeated rungs shuffle symptoms without net progress
- an external review flags infrastructure/contract debts
- deciding between another patch generation and a clean retrain
“同日外部评审定调换路线:冻结 v5~v11 血统(只作回归对照),修结构性问题(latency FIFO 已修 tests/test_action_latency.py、ONNX manifest 契约、离散命令采样、最小奖励表)后从零训直行基线。本规格挂起,不再按此开训。”
train/WALK_V12_SPEC.md § ⚠️ 状态 (2026-08-05) When a contract default changes, old policies must run under a pinned legacy profile - a silent clock swap is out-of-distribution on hardware
legacy-profile-pinningTreat every trained policy as bound to the contract values of its training era: version the deployment profiles, pin old policies to their era's profile in every command, and never let a changed default silently apply to an old artifact.
Symptom
The walk profile's gait clock moved from 0.40 s to 0.50 s for new training, but versions v5-v9 were all trained at 0.40 s - running them under the updated default would silently feed a 25% slower phase clock to policies that never saw one.
Context
The re-test runbook hard-codes --policy-profile legacy_walk_040 into every command for the old versions, with the warning not to omit the flag: the mismatch is invisible (no error, no crash) but puts the policy out of distribution on hardware, where the same file had already documented that off-clock operation collapses gait quality.
Change
Deployment profiles versioned per training era; historical policies permanently associated with their era's profile; runbooks write the profile flag explicitly rather than relying on defaults.
Outcome
Old policies stayed runnable and comparable after the contract moved on; the silent-mismatch failure mode was closed by convention.
Mechanism
Changing a shared default rebinds every old artifact to a contract it was not trained under; unlike a schema break, a value change produces no error - only degraded, unexplainable behavior. Version-pinned profiles make the binding explicit and permanent.
Applies when
- changing any default in the deployment contract (clock, scales, gains) while old policies remain in use
- writing runbooks that mix policy generations
- a re-tested old policy behaves worse than its era's records
“2026-08-02 起 walk profile 的时钟改为 0.50(WALK_V10_SPEC §3)。v5~v9 全是 0.40 训的,本文件所有命令已改带 --policy-profile legacy_walk_040 ——不要省掉这个 flag,否则是拿慢 25% 的相位时钟静默喂旧策略(分布外,真机危险)。”
train/REAL_SWEEP_V5_V8.md § 1. 预检 ⚠️ 时钟改为 0.50 After installing the measured plant, re-run all generations paired on old and new plant - identity metrics carry verdicts, physics metrics re-baseline
plant-swap-invariants-vs-shiftsTreat every plant upgrade as an era boundary: re-run the retained policy set paired (same seeds/flags) on both plants, carry forward only verdicts whose metrics proved plant-invariant, re-baseline the rest - and mine the systematic shifts as measurements of the old plant's biases.
Symptom
With the plant finally fully measured (weighed masses 9.792 kg, bench-identified armature, in-situ friction), no historical sim number was comparable to new runs - "历史 sim 数字跨纪元不可比" - and it was unknown which historical verdicts still held.
Context
The era-2c cross-test ran all seven walk generations on the complete plant under one harness (14/14 survived), then re-ran the same 14 configurations on the OLD plant retrieved from git, same flags and seeds, with a self-check (one historical record reproduced digit-for-digit). The split was clean. Policy-identity metrics moved essentially zero across the plant swap - dominant frequency (v7's period-doubling 1.20 -> 1.20), knee amplitude (9.9 -> 10.0), foot distance (+/-2 mm), saturation (100 -> 100, 0 -> 0) - so all seven cross-generation verdicts (freeze signature, saturation-line closure, knee-collapse location, slip-penalty accounting, N2 lineage, v6's balance, v11's triad) were re-confirmed on the honest plant. Plant-physics metrics shifted systematically with ordering preserved: slip down 10-25% (measured friction makes ground-twisting costlier), landing vertical velocity down 15-50% ("旧 plant 高估落地 凶度"第二次独立证实), landing force mixed (mass up 2.2% vs friction braking the swing - two effects fighting). Exactly ONE behavior-level change: v8's low-speed period-doubling vanished (1.30 -> 2.50, lift normalizing) - confirming it had been machine-dependent bifurcation-edge behavior that armature+friction push off the knife edge, while v7's period-doubling stood untouched: saturation-freeze-driven, a policy property, not a numerical accident.
Change
Era re-baselining protocol: after any plant upgrade, one paired same-seed sweep of all retained generations on old and new plant; verdicts keyed to identity metrics carry over, thresholds re-read against the new-plant table, and the differences themselves become plant-physics findings.
Outcome
Seven verdicts survived with evidence rather than assumption; two causes of the period-doubling family were separated with plant-side proof; and the sim's landing-violence overestimate was independently confirmed a second time.
Mechanism
A policy's structural properties (frequencies, amplitudes, frozen joints) are functions of its weights and survive plant changes; contact-mediated quantities are joint properties of policy and plant and shift when the plant becomes honest. Pairing seeds across plants isolates the plant's contribution exactly, so the sweep both validates history and measures what the old plant had been lying about.
Applies when
- installing measured masses/armature/friction into the sim
- historical thresholds are cited across a plant change
- a hardware-only behavior might be bifurcation-edge sensitivity
“策略身份指标逐位不动:主频(v7 1.20→1.20)、膝摆 … 这些是策略属性,plant 换代携带无损,历史定论因此全部成立。… 唯一行为级变化:v8@0.15 的倍周期消失(主频 1.30→2.50…)——印证当时"分岔边缘、机器相关"的判定:armature+摩擦把 v8 推离刀锋;v7 的倍周期纹丝不动(1.20→1.20),它是饱和冻结驱动的深层属性,不是数值巧合。”
train/README.md § 纪元 2c 全代同机横测 (2026-08-04): 完全体 plant 上历史结论全部存活 Every rung gets written stop criteria - hit any one, stop; tightened when priors say results should come fast
preregistered-stop-criteria-per-rungFreeze per-rung stop criteria (old-skill floors, new-skill deadline, oscillation signature, known pathology signatures) before training, stop on first hit - and shorten the deadline in proportion to how fast your mechanism says results should appear.
Symptom
Continued training past the point of degradation had previously destroyed capabilities (C1 trained away the root's backward skill); without hard stop rules, sunk-cost reasoning keeps runs alive too long.
Context
Standard rung protocol - eval_c_matrix every 100 iters at 5 seeds with a fixed criteria list, frozen before training ("开训前写死,事后不许改"): (1) stand or vx+0.15 at <=3/5 for two consecutive points; (2) vx+0.15 tracking <70% for two consecutive points (vs recorded root baseline); (3) oscillation signature - survival repeatedly crossing zero between adjacent checkpoints, stop on first occurrence, do not wait for confirmation; (4) new-skill-no-progress deadline (e.g. wz tracking <30% or still same-signed after iter 400); (5) a known lineage pathology signature (s1c arm-B: scatter -> half-recover -> collapse).
Change
Stop budgets scale with prior knowledge: when C4-redo4's feed-forward was already proven open-loop, the no-progress deadline was tightened from +500 to +100 iters ("前馈是开环就给 71~96% 的 … 若 +100 还没有 … 不值得再烧").
Outcome
Multiple rungs were stopped exactly on criterion (C4-redo criterion 4 at iter 1200; redo2/redo3 at absolute 900), converting each into a clean hypothesis test instead of a drifting run; no rung burned its full cap on a dead hypothesis.
Mechanism
Degradation of retained skills is a lineage-level injury that later training often cannot undo, so detection latency is capital loss; and a stop rule written before the run cannot be bent by hope. Tightening deadlines when priors predict immediate results converts "no result yet" into evidence against the mechanism.
Applies when
- starting any resumed/curriculum training rung
- deciding whether to keep training a run that shows early regression
- a mechanism-backed change should produce results immediately
“每 100 iter eval_c_matrix.py --seeds 5,命中任一即停 … 存活在相邻 checkpoint 间反复跨越 0(出现即停)… 收紧版:绝对 iter 900(= +200)时 vy±0.10 跟踪仍 <30% 即停”
train/C_LADDER_RUN.md § 3h. 预注册停梯判据(开训前写死,事后不许改)