Training Coach
Doctrine
A report may cite any of these as doctrine-N.
doctrine-1Contract freeze and fingerprint disciplineThe policy I/O contract (observation layout, scales, history semantics, action pipeline) is frozen and fingerprinted; every exported policy is stamped and verified; contract changes ship as new versioned profiles that leave old artifacts bit-identical, and old policies run forever under their era's pinned profile.
Case. The 215-dim omni contract was frozen with a three-machine digest; the one contract-level extension (lateral feed-forward) went in as a new `omni_ff` profile with the old profile provably untouched, and the contract checker caught two real wiring bugs before any training (`contract-freeze-and-checker`). A silently changed gait-clock default would have fed old policies a 25% slower clock - closed by pinned legacy profiles (`legacy-profile-pinning`). A stale derived USD forked plant mass 2.2% until an automated source-vs-derived instrument gated it (`derived-asset-staleness-check`). A gain profile is part of the closed loop a policy was trained in and belongs in its stamp; the recovery line's anchored authority was left out of its manifest and recorded as the gap not to repeat (`gain-profile-belongs-in-the-stamp`), and a second policy behind a deploy-side switch made the handoff state itself a contract (`recovery-two-policies-and-a-state-machine`, `walk-recovery-fsm-handoff`).
Coach application. On any proposal touching obs/action semantics, defaults, or derived assets: demand the version/profile plan, the fingerprint update, and the checker extension in the same change; flag any old artifact that would run under new defaults.
doctrine-2Attribution by resolved training params - never eval-override knobsCapability differences between lineages are explained only by digging each lineage's *resolved* training configuration and eliminating columns; evaluation-side override knobs (kd-scale, power-scale, cycle-time) act on the plant for *every* policy and may serve as deployment mitigations but never as explanations.
Case. Low-friction robustness across 8 lineages x 3840 cells was traced to kd DR *bandwidth* - every lineage had ground friction pinned to (1.0,1.0), so "trained friction" could not be the axis; the parameter axis and the plant axis were explicitly separated after the first attribution conflated them (`kd-bandwidth-mu-law-attribution`). "Weak turning" on hardware was a power-scale plant effect, not a training gap (`deploy-knob-attribution-before-retraining`); slowing the deploy clock was out-of-distribution, not a feature (`cycle-time-override-is-ood`). The ground truth for what a run trained under is the logged per-run config, not the source tree (`resolved-config-is-source-of-truth`).
Coach application. Whenever asked "why is lineage A better", require the resolved-param table first; kill zero-variance columns; refuse explanations phrased in eval-knob terms; when a knob helps, label it deployment mitigation.
doctrine-3PASS gates become constraints; FAIL gates become objectivesOnce a skill passes its gate, that gate converts into a standing regression constraint (budget <= 2/20 against the parent baseline) for all later training; gates currently failing are the only legitimate objectives of the next rung.
Case. The C ladder ran one frozen 13-cell x 20-seed matrix at every rung with promotion = "new skill PASS and old skills within regression budget"; C1 was stopped and re-rooted precisely because it trained away the root's backward PASS (`fixed-acceptance-matrix-per-rung`, `preregistered-stop-criteria-per-rung`). The C4 product shipped only at 260/260 cells with zero regression.
Coach application. Keep the ledger: every PASS adds a constraint row; propose rungs only against FAIL rows; treat any constraint violation as stop-and-attribute, never "the next rung might win it back".
doctrine-4One variable per ladder rung - counted against what the checkpoint sawA rung changes one variable, where "one" is counted against the checkpoint's actual training state, not against the current config's diff; batching is allowed only when each change owns a disjoint symptom space with a pre-registered ablation order.
Case. Two rungs failed identically because resuming s1e-500 under the evolved config silently added four plant variables the checkpoint had never seen ("单变量纪律不只看「我改了什么」,还要看「checkpoint 见过什么」" - `resume-state-dr-audit`). v8 legally batched four orthogonal fixes with a written ablation order (`orthogonal-batch-with-ablation-order`); v9 spent one run completing a 2x2 factorial so either outcome convicted a factor (`fill-the-missing-factorial-cell`); v10b's three-way ablation wrongfully convicted the clock and had to be retried fairly.
Coach application. Before any resume: diff cfg against the checkpoint's logged training state. Before any batch: require the symptom-ownership map and ablation order in writing.
doctrine-5Pre-register risks, readings, and stop criteria before the ladderBefore a ladder or risky rung, write down the known risks, the interpretation of every plausible outcome, and hit-any-one stop criteria - frozen before training, tightened when priors say results should come fast.
Case. The C ladder opened with three numbered risks including the exact falsification condition for its own root choice; A/B arms carried "预注册读法(事后不改)" tables; a level expected to fail was run anyway for its pre-registered diagnostic value (`preregister-risks-and-fork-readings`). Stop criteria caught C4-redo rungs at +200 instead of full caps (`preregistered-stop-criteria-per-rung`); hardware sessions pre-registered per-config expected signatures and the disagreement rule "不改结论改账" (`preregistered-real-expectations`, `feasibility-accounts-lock-design-point`).
Coach application. Refuse to open a rung without the written risk/reading/ stop block; after results, read conclusions off the pre-registered table and flag any post-hoc reinterpretation.
doctrine-6Plant parameters are measured, never inventedEvery plant number carries measurement provenance: armature = N^2 x rotor inertia from no-load tests, friction split by rig and by API column, torque limits shaped by per-joint gait peaks, latency traced through the real pipeline, masses weighed - and DR bands are additive around the measured nominal, sized to the measured dispersion.
Case. Guessed friction was 2.5x low and guessed damping 5x high (`friction-measured-not-guessed`); armature had been 0 with a 9:1 gearbox (81x reflected inertia, `armature-n2-rotor-inertia`); a uniform torque derating was "the wrong shape" vs measured peaks (`torque-limit-shape-by-measured-peaks`); the delay implementation itself was a wrong plant for a whole lineage (`latency-lerp-reverse-extrapolation`); the run design point was locked by three accounts including the tau_limit/kd speed ceiling (`feasibility-accounts-lock-design-point`); identified friction had to land in the right simulator API columns to act at all (`sim-api-friction-columns`). The recovery and one-leg lines opened with the same kind of accounts before any reward existed - a connected static path and the torque along it for an armless get-up, and the gains single support needs to be holdable at all (`get-up-feasibility-accounts-before-training`, `single-support-gain-authority-probe`).
Coach application. For any plant value in a config review, ask "measured how?"; reject absolute ranges with no nominal; check API column mapping and derived-asset regeneration whenever measured values land.
doctrine-7Sim2sim gate before sim2real - under deployment conditionsEvery checkpoint passes a second, independently built simulator before hardware, and both the gate and the smoke loop run under the measured deployment conditions (real pipeline delay, honest contact parameters, the deployment gain/power profile).
Case. The standing order "先sim2sim 再sim2real" (`sim2sim-gate-before-sim2real`); acceptance flipped to match hardware only under measured condim/torsional friction (`eval-plant-honesty-contact-params`); gates moved permanently to `--delay 2` after the kicking incident (`pipeline-latency-is-plant-not-dr`); and the harness itself must be audited - a frame-convention bug in the cross-sim evaluator invalidated a whole line of verdicts (`body-frame-velocity-api-audit`). The recovery line's second simulator caught a torque penalty paid for by bracing the legs together (`torque-penalty-bought-by-leg-bracing`), and a 1.8x torque disagreement between the two plants stayed binding because its one surviving explanation was never tested (`torque-disagreement-between-simulators-unresolved`).
Coach application. Block any hardware request lacking a second-sim PASS at deployment conditions; when sim2sim and training-side metrics disagree, treat the evaluator as a suspect too.
doctrine-8Observation honesty - the actor's inputs are a hardware contractThe actor observes only signals the real robot produces with realistic noise; privileged truths go to the critic; history windows are estimators and must train under plant variation; rewards on quantities the actor cannot observe buy only average suppression, never closed-loop correction.
Case. Ground-truth velocity/forces went critic-only (`observation-honesty-critic-only`); frame_hist under zero DR memorized the trainer's plant fingerprint - 0/20 transfer (`history-obs-needs-plant-variation`); world-frame yaw rewards could not teach pull-back because heading is unobservable to the actor - correction was routed to the deploy outer loop instead of breaking the contract (`reward-observability-limit`, `deploy-heading-loop-and-align-training`).
Coach application. Audit every actor-obs element for hardware existence; require minimal plant jitter whenever history/recurrence exists; for each reward, ask "can the actor see this error?" and route correction tasks to outer loops.
doctrine-9Reward economics are audited in realized currencyReward design decisions are made on realized per-step magnitudes under the actual policy and command distribution: price the do-nothing optimum before adding a mode, compare achieved values to the computed ignore-floor, calibrate thresholds between measured healthy and sick distributions, and ship every new penalty with a withdrawal clause.
Case. feet_air_time at weight 2.0 realized 0.038 vs tracking 1.2 - drag was rational (`realized-contribution-audit`); ignoring a vy command cost 28-180x less than ignoring vx until a gated tracking term was added (`reward-cost-of-ignoring-audit`, `gate-new-reward-terms-by-command`); achieved-vs-floor separated "never learned" from "priced out" (`ignore-floor-diagnosis`); the foot-distance wall was placed between measured healthy (0.6% tax) and sick (55%) policies (`calibrate-threshold-between-healthy-and-sick`); the landing penalty carried a pre-registered stand-down condition and actually stood down (`calibration-threshold-with-withdrawal-clause`); two clearance terms were inert until zero-points and gate occupancy were checked (`inert-reward-term-audit`). A get-up policy sat because three gated terms paid the seated pose 84% of the return and the one term that could tell sitting from standing was an exp kernel reading 4.6e-5 at the real error (`seated-basin-dead-exp-kernel`); a torque-tail term was weighted by its measured steady value beside a peer term after the estimate proved 12x off (`tail-torque-needs-hinge-on-computed-demand`).
Coach application. Never discuss weights in the abstract: demand the realized-contribution table, the ignore-floor number, and the healthy-pay calibration before any reward edit is approved.
doctrine-10The zero-cost option must be the desired behaviorFor every penalty, name what the zero-cost option is; penalize failure events (slip, saturation excess, contact in flight windows), never the motion or joints that healthy behavior uses; make degenerate strategies fatal via termination where penalties cannot price them out.
Case. Joint-usage penalties for drift taxed a 1.4%-of-momentum channel 2.7/step and collapsed training; the slip penalty costs a non-slipping gait exactly zero (`penalize-the-slip-not-the-joint`). A frozen-at-clamp joint pays zero action-rate forever - only a pre-clip saturation penalty flips the cheat economics (`saturation-cheating-zero-rate-cost`). Ungated phase shaping made standing 42x more expensive than stepping and cooked the hip motors (`moving-gate-42x-stand-tax`); crouch-shuffling lived until a height termination deleted it (`termination-closes-degenerate-basin`). A gated penalty is an exit: the policy parked just outside an uprightness gate, then just under a height gate, to stop paying a stance tax, and only a positive band plus an always-on guard closed both (`penalty-gate-is-an-escape-hatch`); a soft-limit penalty that charged the standing pose itself bought a 4.1 deg lean (`soft-limit-penalty-charges-nominal-pose`); an unpriced foot attitude was spent on edge-standing (`unpriced-foot-attitude-is-a-free-variable`); and the one-leg line listed its cheapest cheats before training and still met one through a zero-gradient band (`enumerate-cheapest-cheats-before-training`, `binary-band-reward-fake-touchdown`).
Coach application. Run the "零代价的选项是什么" audit on every proposed term; convert motion taxes into event-conditional penalties; check the termination set against each known degenerate strategy.
doctrine-11Measurement discipline: independent referees, signs, distributionsA disputed measurement is adjudicated only by an independent algorithm from raw state; directional ability requires sign-antisymmetry under command reversal; bimodal metrics are reported as mode shares (never medians, never 3 seeds); ratios are not comparable when totals change; reward values compare only within one command distribution; single chaotic events never cross machines.
Case. The triple reversal - a good metric was "refuted" by a sibling metric that shared the disease (`independent-referee-for-metric-disputes`, `body-frame-velocity-api-audit`); same-signed +/- responses were bias, not turning (`same-sign-response-is-yaw-bias`); the swing median sat in a bimodal gap (`median-hides-bimodal-distribution`); "v6 is jitterier" died on absolute energies (`ratio-metrics-need-absolute-check`); yaw gain measured 15x wrong in an oscillating frame (`heading-integral-not-body-rate`); a 44% improvement evaporated under same-distribution comparison (`same-distribution-reward-comparison`); drift direction was a limit cycle (`multiseed-sign-test-for-drift`); a cross-machine push cliff was chaos (`single-impulse-recovery-is-chaotic`).
Coach application. Before accepting any surprising number: ask for the independent recomputation, the sign pair, the distribution shape, and the comparison conditions. Retract in writing when a metric falls.
doctrine-12The deployment pipeline is plantIrreducible pipeline properties - action latency, rate limits, power/torque scaling, teleop command mappings - are part of the nominal plant, modeled from day one and reproduced in every gate; deploy-side scalings are crutches that flag unmodeled plant, and they cannot be algebraically folded into training constants.
Case. Right-leg kicking was over-trained-delay x loop gain; power 0.8 was a gain-reduction crutch that retired when the delay was modeled (`pipeline-latency-is-plant-not-dr`); power derating damages non-forward axes first (`power-scale-hurts-nonforward-axes`); training at 0.4 scale as the "twin" of deploying 0.5 x 0.8 collapsed 0/20 (`deploy-scaling-not-training-equivalent`); one shared teleop speed sent an out-of-band lateral command and the robot clipped its own foot (`teleop-command-band-per-axis`); the latency DR range had not even covered the measured pipeline (`latency-dr-covers-measured-pipeline`). A rate limiter added at deployment only clipped a policy that kept commanding (`deploy-rate-limiter-windup`); moved into training and anchored on the last command it became an integrator in the balance loop (`slew-anchor-is-an-integrator`); anchored on the measured angle it bounded torque and kept the bandwidth (`beta-anchored-action-target`). The walking lines' safe setting, power-scale 0.8, cut the ends of the recovery policy's full-range travel and left its spikes alone; a gain inside the trained band did the job (`power-derating-cuts-full-range-contract`).
Coach application. Demand the measured pipeline latency/limits in the plant model and in gate conditions; treat every deploy-side derating as a question ("what is this compensating?"); block per-axis command sources that exceed training bands.
doctrine-13DR budget is finite; its distribution is the measured supportRobustness is a conserved budget: disturbance training on an already-hardened lineage borrows from existing margins; DR ranges span the measured deployment support - no fictitious tails (they buy degenerate gaits), no single constants (they allow thin-margin specialization); harden the plant only after the task distribution is final.
Case. The same push dose helped a narrow lineage and damaged a balanced one - budget conservation (`push-dr-conditional-budget-conservation`); wide latency tails bought drag-glide, constant values shipped 60% thinner tilt margins - the answer is a narrow band on the measured support (`dr-tail-plant-continuation`, `constant-value-dr-overfits-margin`); task-first ordering because hardening a soon-to-change task wastes budget (`task-shaping-before-plant-hardening`); COM randomization used deliberately as a behavior-shaping tool, and rolled back on symptom per its own contract (`com-randomization-forces-leg-spread`, `com-dr-rollback-on-symptom`). DR that is switched on can still be thin: the run policy fell in the frontal plane its gain-and-latency randomization never touched (`thin-dr-judged-by-channel-coverage`), and a friction priority settled under one action contract had to be re-measured under the next (`friction-priority-re-measured-after-plant-change`).
Coach application. Before any DR rung: check the untrained policy against the spec, the lineage's current DR load, and the measured real-world range; after it: audit retained margins, not just the new tolerance.
doctrine-14Gates measure what hardware feels: posture, margins, stripped assistsAcceptance batteries carry posture-class rows (tilt max median, per-joint L/R asymmetry, temperature) beside task rows, graded margin columns beside binary gates, chirality scored per side, at least one condition that removes the environment's free stabilization, and validated predictive scalars promoted into the gate.
Case. Three same-shaped judging errors - survival, displacement, wz-difference - all missed what the operator felt; posture metrics had the predictive power (`task-metrics-vs-posture-metrics`, `stand-gate-posture-not-survival`); binary survival saturated and hid a 60% margin gap (`constant-value-dr-overfits-margin`); v5 passed everything on the ground and failed suspended (`suspension-probe-removes-free-stabilizer`); the hip_roll (l+r) scalar predicted real drift direction and ordering and entered the battery (`hip-roll-sum-predicts-lateral-drift`); averages hide chirality (`chirality-scored-separately`); gait-quality gates are judged at speeds that demand a gait (`low-speed-commands-reward-dragging`). The recovery line added the rest of the kit: where failed episodes end, not only where they started (`end-state-confusion-matrix`); a frozen acceptance distribution with a pinned seed (`frozen-acceptance-distribution-and-pinned-seed`); video of the metric rollout itself (`video-as-acceptance-record`); and the admission that a 10 s episode cannot see a stance that fails after a minute (`episode-length-bounds-what-a-gate-sees`). The one-leg line removed a foot-spacing wall that no gate measured, and the feet met on hardware (`removed-wall-returns-on-hardware`).
Coach application. Review every battery for posture rows, margin columns, per-side scoring, and an assist-stripped condition; when operator feel and gates disagree, suspect the metric class first.
doctrine-15Fork and root selection: recoverability, maturity, frozen rewardsChoose fork roots by which candidate's deficits the coming training can pay back (precision is recoverable; lost plasticity, symmetry, and margins are not); prefer mature checkpoints as roots even when younger ones score better as products; never fine-tune through a reward change - continuation is legal only with the reward frozen and plant/DR widening one rung at a time.
Case. s1e-500 beat higher-precision candidates because its exclusive strengths were unrecoverable (`fork-root-recoverable-shortfall`); the b300 arm proved maturity is capital against adaptation shock (`root-maturity-vs-product-quality`); the B-arm scatter/half-recover/collapse signature falsified reward-change fine-tuning and drew the legal boundary for S2 continuation (`fine-tune-reward-change-falsified`).
Coach application. For root debates, build the exclusive-strengths table and ask "which side can be trained back?"; require dual-arm evidence for maturity claims; classify any proposed continuation as reward-frozen or not before approving.
doctrine-16Curricula: verified engagement, lineage counters, disease-phase gatingAutomatic curricula must prove they engage (a saturated ratchet is constant DR wearing a curriculum's name); every ramp counts lineage-cumulative progress, not per-process steps; penalties aimed at late-stage pathologies ramp in after exploration noise decays; difficulty rises on measured per-stratum success, never on schedule.
Case. The s1f ratchet capped at iter 248 and never engaged (`auto-curriculum-engagement-check`); the saturation ramp re-fired at +600 after every resume and no shipped product ever saw the penalty (`curriculum-counter-lineage-steps`); the same penalty worked once gated to the disease phase and became an untouchable mechanism (`gate-penalties-to-the-disease-phase`); record-high aggregate reward hid a fully-failing delay stratum (`aggregate-metrics-mask-subgroup-failure`); bucket share is not a gradient lever (`bucket-share-is-not-a-gradient-lever`). An assist curriculum keyed to a pooled success share was withdrawn on the strength of the categories that already worked (`curriculum-criterion-conditioned-on-lagging-category`); a pace set by per-step income moved only when that income was time-gated (`per-step-income-drives-speed-time-gate`), and the same gate had to be retired in a lineage without the disease (`time-gate-vs-wide-stance-retire-the-fix`).
Coach application. Ask every curriculum three questions: does it engage (show the internal state)? what does it count (process or lineage)? when is it present (against the pathology's phase)? Check where shipped checkpoints sit relative to every ramp.
doctrine-17Probe before training: feasibility first, hypotheses in tablesAfter two failed training attempts at a skill, stop training: demonstrate the behavior open-loop, enumerate hypotheses in a written table audited against actual configs cheapest-first, race one probe per side of the sim2real boundary for hardware-only pathologies, and use suspended tests to acquit or convict actuators before blaming authority.
Case. "在黑暗里试钥匙" - four sidewalk rungs failed until an open-loop probe separated exploration/waveform/authority in one experiment (`open-loop-probe-before-reward-tuning`); the foot-drag mystery fell to a seven-hypothesis config audit (`hypothesis-table-code-audit`); the period-doubling was resolved by racing a reward-side and a plant-side evidence line - and both paid off, one per sub-case (`period-doubling-evidence-race`); the suspended test acquitted the roll actuator in one measurement (`suspended-test-isolates-actuator-authority`). A read-only configuration probe told a wall from a slope in the recovery line's seated basin (`configuration-probe-wall-not-slope`), and the fix it pointed to - where the feet are - took prone from 0/159 to 158/159 (`prone-dead-end-is-foot-placement`); a knob that did not move its variable was recorded as no test of the idea (`dof-vel-penalty-is-not-a-pacing-knob`).
Coach application. When a skill resists training, prescribe the probe before any further reward edits; require verified target trajectories before imitation terms; keep a falsified-fixes list so closed roads stay closed (`amplitude-cut-falsified-yaw-fix`).
doctrine-18External advice is recomputed locally; values transfer as ratiosEvery external suggestion is classified adopt / already-have / modify / trap by recomputing its claim on the local reward table and probe data; numeric values transfer only as dimensionless ratios (to tracking weight, leg length, sqrt(gL), control rate); citations are verified to exist.
Case. "Start vy very small" would have destroyed sidewalk learning on this reward table - the gradient scales quadratically (`external-advice-audit-against-own-arithmetic`); swing-height targets and weights transferred correctly only through leg-length and tracking-ratio scaling (`transfer-ratios-not-absolutes`); the "6-step delay" was refused for lacking a control rate (`latency-dr-covers-measured-pipeline`); a borrowed reference's structure was FK-verified and its amplitude re-derived from the division of labor (`reference-structure-fk-amplitude-division`); retrieval agents fabricated verbatim arXiv quotes - only source-verifiable material was used; and one dismissed suggestion later proved right for a different mechanism, and was credited (`cycle-average-tracking-for-gait-quantities`). An advisor's staged state machine turned out to exist in none of the three papers it cited, and reading them changed the plan (`advisor-paraphrase-vs-paper`).
Coach application. Intercept every "paper X does Y" with the local recomputation; convert absolutes to ratios before comparison; verify quotes; revisit dismissed advice when new mechanisms appear.
doctrine-19Hardware sessions are scripted experiments, not tuning sessionsReal-robot time executes a pre-registered matrix: risk-ordered (baseline first, fragile last with a spotter), stage-gated (suspended smoke before ground), A/B sessions bracketed by a repeated reference run, operators briefed on measured zero-command and untrained-axis behavior, chirality-aware disturbance protocols, no field tuning - the only legal field changes are scripted, single-variable, and self-reversing.
Case. The S2 acceptance sheet (`risk-ordered-real-deployment`, `battery-bracketed-real-ab`, `know-zero-command-behavior`, `push-test-chirality-protocol`, `no-field-tuning-protocol`); the RAM-only torque experiment with automatic power-cycle rollback (`reversible-single-variable-field-experiments`); and the sim-veto rule - even sim's condemnations get one safeguarded hardware check when they judge the purpose-built configuration (`sim-veto-needs-real-confirmation`). The recovery line's first real run went ahead with its preconditions unmet and was stopped as dangerous (`first-real-get-up-violent-stage-one-policy`); after it: a staged hang, mat and floor protocol (`staged-hang-mat-floor-for-get-up`), a fixed power-cycle pre-flight and two-machine discipline (`power-cycle-preflight`, `two-machine-config-discipline`), a fall guard replaced rather than switched off (`fall-guard-becomes-a-state`), and logs that are part of the run (`hardware-log-is-the-attribution-input`).
Coach application. Turn every hardware request into a runbook with order, gates, brackets, briefing, and anomaly plays; refuse improvised parameter changes on the floor.
doctrine-20Close questions in writing; restart when the debt is structuralAudited questions get frozen verdicts with citable wording and an explicit reopening bar; hardware verdicts are dated by deployment-stack and calibration state and expire when those change; and when successive rungs shuffle symptoms without net progress, freeze the lineage as regression baselines, pay the structural debts, and retrain minimal - carrying laws and instruments, not weights.
Case. The chirality and COM questions were closed with frozen wording and "no reopening without new hard evidence" (`frozen-verdicts-semantic-boundaries`); v5/v6's condemnations expired with the deploy stack (`stale-verdicts-under-old-stack`); a 2-degree calibration fix moved the whole runnable envelope (`zero-offset-calibration-shifts-envelope`); plant upgrades are era boundaries with paired re-baselining (`plant-swap-invariants-vs-shifts`); and the 2026-08-05 reset froze v5-v11, fixed the latency FIFO / manifest / sampling / reward-table debts, and restarted - producing the lineage that reached hardware SOTA (`freeze-lineage-fix-structure-restart`, `minimal-reward-table-with-provenance`). The recovery line's real-robot verdicts ended up in three places that disagree, one of them an undated note in a command file (`write-hardware-verdicts-back`).
Coach application. Maintain the closed-questions ledger and quote it when symptoms recur; stamp verdicts with stack/calibration versions; when a team is three rungs into symptom-shuffling, raise the restart question explicitly with the freeze-fix-restart pattern.
doctrine-21Name the quantity in the space it lives inA goal, reward term or acceptance criterion about the feet, the base or the contact state is computed from the quantity itself - world poses, forces, per-category outcomes - never through a joint-angle, single-signal or pooled stand-in that assumes everything else sits at nominal; and every detector is validated on a behaviour known not to contain the event before it becomes a gate.
Case. The recovery line was caught three times: |ankle roll| as "flat feet" sold stance width and the real robot slid into the splits, a hip-roll criterion was confounded by 50 deg of yaw, and the joint table said 0.271 m where the feet were 0.159 m apart; task-space terms produced the first flat, wide stance (`joint-space-proxy-for-task-space-quantity`). Flight detection lied in both directions across two lines - foot height flagged 40% false flight on a walking gait, contact force alone flagged slip chatter as hops (`contact-detector-single-signal-lies`). A pooled height average described a robot that did not exist - six in ten standing, four in ten sitting (`zero-partial-credit-is-not-an-iteration-problem`) - and the walking line had learned the same lesson on yaw rate (`heading-integral-not-body-rate`).
Coach application. For every reward term and gate row, ask what physical quantity it stands for and whether it is measured directly; flag joint-space or single-signal stand-ins for task-space goals, ask for a detector validated on a negative control, and split pooled metrics by category before reading them.
doctrine-22Continuation needs a live gradient; a release is chosen by a scanContinue a converged policy only on a change that creates a live gradient, on a short budget, with every checkpoint scanned on the transfer axis; choose a release by running the full battery over a band of checkpoints and stop on signals, never by taking the last one; and when edits to the terminal phase cannot move a behaviour, roll back and retrain with the constraint present from the start, keeping the order in which the lineage acquired its mechanisms as explicit curriculum phases.
Case. A continuation with no new gradient drifted MuJoCo transfer from 100/98% to 80/28% while every Isaac gate stayed perfect, and a live-gradient continuation at the same depth kept it (`converged-continuation-is-poison`). One-leg checkpoints 100 iterations apart failed 1 and 38 of 40 cells, and late ones degraded (`checkpoint-choice-is-a-full-gate-scan`). Four in-lineage stance fixes failed because the stance was the end of the get-up path, and from scratch it grew right (`stance-decided-by-get-up-path`); fixes stacked on degraded states were rolled back by the user (`stop-stacking-roll-back-and-audit`); and the lineage's final recipe, trained from scratch in one run, sat at 0% because the order of its curriculum was part of the product (`curriculum-history-is-part-of-the-product`). The omni line's short adaptation budgets and mature roots are the same law seen from the other side (`continuation-budget-not-from-zero`, `root-maturity-vs-product-quality`).
Coach application. Before approving a continuation, ask for the new gradient, the budget and the transfer axis in the scan; before approving a release, ask for the scan; after three rungs without progress on the target, propose rolling back to the last good checkpoint and a from-scratch phase plan instead of a fourth patch.
Experience cards
104 cards matching “inert-reward-term-audit”.
Prove an armless get-up exists before training it - a connected static domain, 25% torque on the cheapest path, an 8 mm hand-over gap, a static roll-over - and write down what each scan cannot represent
get-up-feasibility-accounts-before-trainingBefore training a get-up or any multi-contact skill, compute the quasi-static accounts - connectivity of the static domain, torque along the cheapest path, hand-over gaps, COM shift available for rolling - and state which configurations each scan cannot represent; when a policy gets stuck in one of those, extend the scan before blaming the reward.
Symptom
A torso-and-legs robot has no arms to push off the ground; whether it can get up from the floor at all was unknown when the line opened.
Context
recovery_feasibility.py ran three accounts before any training (the run line's "hard accounts first" discipline): a sagittal quasi-static scan (0.05 rad grid, 44,520 configurations, MuJoCo FK, flat-foot assumption). (1) The static standing domain (COM over the feet, torques in limit) has 29,586 cells, flood-fill connected with no islands, from a 0.097 m deepest squat to the 0.384 m stand. (2) The minimum-torque path peaks at 25% of the limits (knee 2.9/12, ankle 3.7/17 N*m) - a 4x margin. (3) All 508 ground-contact configurations have the contact behind the COM; the smallest gap to pure foot support is 8 mm. A roll-over account: swinging both straight legs to one side shifts the COM 96 mm against a 62 mm torso half-width - 1.6x, so rolling needs no momentum. Three conclusions were written down for later attribution: the legs are 80% of the mass (swinging them moves the COM), prone has no flat-foot hand-over face (merge into a supine/side sit first), and supine needs no sit-up (hip flexion is limited to 75 deg).
Change
The accounts gated opening the line and were cited in every later argument about what the robot can physically do.
Outcome
They held where they applied: in V1.0 every fall category was righted under a hard rate limit, which the spec records as the quasi-static roll-over account verified by training, and the 25% torque path was the basis for pursuing a slow get-up. They also misled once: account (3) is sagittal, and on 08-09 the spec corrected its scope - it cannot represent the splayed W-sit where the policy actually stalled. A follow-up prone hip-ROM scan (471,625 cells) found 3,912 two-foot-contact cells and none with both soles within 25 deg of level (best 40.2 deg): a flat-footed push-up from prone is infeasible on this robot, so the fix became where the feet go after sitting up.
Mechanism
A get-up needs a connected path through statically feasible configurations and enough torque along it; quasi-static accounts bound both cheaply, and momentum can only make the real problem easier. A reduced-dimensional scan, though, only speaks for the configurations it can express.
Conflicts
In R0.1-R0.2 the spec read account (3)'s "prone has no front hand-over" as "prone lacks the roll-over skill"; R0.3's confusion matrix showed prone had righted its torso 159/159, and the spec then restricted account (3) to the sagittal configurations it models.
Applies when
- opening a get-up, recovery or climbing skill on a new robot
- a robot lacks arms or other obvious contact options
- a policy stalls in a configuration a feasibility scan never modelled
“本机 **torso + legs、无手臂可撑地**,开训前先证明存在不依赖手臂的物理解 … 双腿同侧直腿摆最大横移 **96 mm = 1.6×** … **静态摆腿即可翻身,无需动量**”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §1 机械可行性判决(2026-08-09,recovery_feasibility.py 三笔账) The +/-50 mm lateral COM randomization meant to spread the legs coincided with legs pulling IN - rolled back per its own pre-registered contract
com-dr-rollback-on-symptomWhen adopting a DR value that covers no local measurement, write its intent and rollback trigger into the config at adoption time; roll it back as the control arm the moment the symptom contradicts the intent, and promote the symptom's metric into the acceptance battery.
Symptom
After v7 adopted the reference developer's oversized lateral COM randomization (+/-50 mm) explicitly to force leg spread, the real robot's legs narrowed instead - lateral mean 154 mm / closest 107 mm in sim (nominal 214.5), narrower still on hardware with occasional leg contact.
Context
The rollback was clean because the adoption had been honest: the robot.yaml comment recorded the intent AND that the +/-50 value covered no local measurement (only a 16/7 mm measured offset existed; even the prior widening to +/-20 was subjective), plus the reference's own reported side effect (base sway) and the note "这一项要单独跑、 单独归因". When the opposite symptom appeared, v8 returned y to +/-20 mm as the control arm ("要么没起作用、要么帮了倒忙 … 按约定退回做 对照"), kept x/z untouched (a noise-level difference not worth another variable), and named the second suspect: the landing penalty itself, via the reference's own three-link chain (landing penalty -> stance narrows -> spacing penalty needed). A gate lesson was booked in the same table: v7's sim numbers had ALREADY crossed the line (154/107 vs v5's 182/147) - "这个指标本可拦下 v7" - so foot-distance became a standing acceptance row (min >120 mm, zero leg-leg contacts).
Change
base_com_offset_m y: 0.050 -> 0.020 (x/z kept), regenerated through the export tool rather than hand-editing derived files; foot-distance acceptance row added.
Outcome
A borrowed DR lever with no local measurement basis was retired the moment its symptom contradicted its purpose, at single-variable cost; the metric that would have caught it pre-hardware entered the gate.
Mechanism
DR ranges shape behavior through the policy's robustness strategy, which is jointly determined with every reward term; a lever that forces stance width on one robot can be dominated by a stronger narrowing pressure (landing softness) on another. Levers adopted without local measurement must carry their own rollback trigger, because there is no nominal to argue from when they misbehave.
Conflicts
Causality is not fully closed in the source: the narrowing may come from the landing penalty rather than the COM lever ("腿距的第二嫌疑人是 ④ 本身"); the rollback is the pre-agreed control experiment, not a verdict that the lever caused the narrowing.
Applies when
- importing DR ranges or behavioral-forcing randomizations from references
- a DR lever's observed effect contradicts its documented purpose
- a sim metric existed that would have caught a shipped regression
“⑥ 的本意 … 是逼策略把脚分开;真机结果是脚向内收且偶发相碰——要么没起作用、要么帮了倒忙。… 注释当时就写了"这一项要单独跑、单独归因"。现在症状出现了,按约定退回做对照。”
train/WALK_V8_SPEC.md § 3. 改动 C — 质心随机化退回(撤销 v7-⑥ 的 y 项) A single run's drift direction may be a limit cycle, not a policy bias - check the sign distribution across seeds
multiseed-sign-test-for-driftDistinguish "bias" from "broken symmetry limit cycle" by the sign distribution over many seeds; report drift as (mean, sign split), and never compare single-run drift magnitudes across versions.
Symptom
Net yaw over 15 s appeared to worsen from -41 deg (v2) to -84 deg (v4), inviting the conclusion that the new version drifted more.
Context
The Isaac-side view across 32 environments told a different story: per-env yaw was mixed-sign (20 negative / 12 positive) with mean ~0 - the drift is a limit cycle whose direction depends on initial conditions, not a systematic policy bias. The single MuJoCo run had sampled one draw from that distribution, so its magnitude could not be compared across versions as if it were a property.
Change
Evaluation rule: before classifying drift as systematic, run multiple seeds and examine the sign distribution; single-trajectory drift magnitudes are samples, not properties.
Outcome
The v2-vs-v4 drift "regression" was reclassified as not-established; later drift work (hip_roll l+r bias) used cross-policy, cross-seed evidence instead.
Mechanism
Symmetric dynamical systems can settle into either of two mirrored limit cycles; the selected cycle is decided by noise and initial state. A statistic whose sign is initial-condition-dependent has no meaning as a single sample - only its distribution does.
Applies when
- comparing heading drift or lateral drift across policy versions
- a symmetric-looking behavior shows a consistent direction in one run
- deciding whether to fix "drift" in reward or calibration
“偏航反而变差(−41° → −84°):注意 Isaac 侧 32 env 的逐 env 偏航是正负混合(20/12)、均值 ≈0,说明这是极限环性质(方向随初值)而非策略偏置 —— MuJoCo 单次跑测到的是分布里的一个样本,不能当作系统性偏差。要判断需多种子统计。”
train/WALK_DIAGNOSIS.md § walk_v4 独立验收 读法 (偏航) Cutting swing amplitude 40% raised yaw-momentum demand 53% - the falsified fix is recorded so nobody walks that road again
amplitude-cut-falsified-yaw-fixTest gait fixes against the quantity the ground must actually supply (torque/force rates vs friction ceilings), not against kinematic proxies; record falsified fixes with their mechanism so the search space shrinks permanently.
Symptom
Support-foot yaw slip stayed at ~223 deg (vs 225 deg) after walk_v6 cut joint swing amplitudes by ~40% (hip_pitch 20.6->10.4 deg, knee 31.3->18.8 deg) - the change built on the theory "smaller swing = less yaw momentum to dump into the ground".
Context
Direct measurement inverted the theory: yaw-momentum amplitude ROSE 16% (+/-0.1000 -> +/-0.1159) and its rate of change rose 53% (1.86 -> 2.84 N*m demanded from the ground), pinned exactly at the foot's supply ceiling (2.8-3.3 N*m at mu 0.6-0.7) - so slip could not drop. The extra demand lives in higher harmonics: v6's crisper foot placement (better clearance 34 mm, lower landing force) shortens the momentum- exchange window, concentrating the same exchange into less time. The verdict was written as a closed road: "下一轮不要再走这个方向". An honest residue was also booked: WHY amplitude down but momentum up 16% remained unresolved, with the named next step (per-rigid-body decomposition of H_z, since per-joint RMS sensitivity ignores phase correlations).
Change
The "reduce amplitude to reduce yaw momentum" lever was removed from the planning space; future yaw-slip work redirected toward the supply side (friction) and momentum-rate mechanics.
Outcome
Slip unchanged (225 -> 223 deg); the falsification and its mechanism became a permanent constraint on the fix search space.
Mechanism
Ground yaw torque demand scales with the rate of change of angular momentum, not its amplitude; kinematic amplitude cuts that also sharpen contact timing can raise dH/dt while lowering range. When demand exceeds the friction-limited supply ceiling, slip is set by the ceiling, so demand-side changes below the ceiling do nothing visible.
Applies when
- attacking foot slip or yaw drift via gait shape changes
- a fix targets an amplitude while the constraint is a rate
- documenting a failed intervention after a version comparison
“walk_v6 | ±0.1159 (+16%) | 2.50 Hz | 2.84 N·m (+53%) … 脚的供给上限 2.8~3.3 N·m(μ 0.6~0.7)—— v6 正好顶在天花板上, 所以滑移一点没降。… 结论: "减小摆动幅度以降低偏航动量"这条被 v6 证伪 —— 砍 39% 幅度, 需求反升 53%。下一轮不要再走这个方向。”
train/WALK_DIAGNOSIS.md § ② 未生效的机理: 减小摆动幅度反而让偏航需求上升 Drop the frozen policy into chosen configurations - a squat 2.7 cm lower than the stuck pose stood 52% of the time, the stuck W-sit 0%, and the interpolation between them showed a wall, not a slope
configuration-probe-wall-not-slopeWhen a policy is stuck, probe the frozen policy from a grid of hand-placed start configurations, including interpolations between the stuck state and a nearby state it escapes from; one read-only experiment separates height, torque, sampling and configuration and tells you whether to prevent entry or train the exit.
Symptom
After R0.3 the policy stood from 62% of starts and never from the W-sit it fell into; height, torque, missing samples and reward were all plausible suspects.
Context
A read-only probe placed the R0.3 policy directly into specified configurations. Squats (hip, knee, ankle) = (-.65,-1.3,-.65) stood 100%, (-1.0,-2.0,-1.0) 89.8%, (-1.2,-2.4,-1.2) at 0.176 m 52.3%; the measured W-sit at 0.203 m 0.0%; the account-(3) hand-over state (146 deg tilt) 34.4%; linear interpolations from the W-sit toward the squat at 25/50/75% stood 0.0/0.0/3.1%. The squat family's quasi-static torque is 16% of the limits, and the W-sit was visited ~9 s per episode in training. FK showed the squat family (-a,-2a,-a) keeps the torso vertical, the feet flat and the COM over the feet all the way from 0.146 m to 0.384 m.
Change
Height, torque and sampling were eliminated in one experiment; the next rungs targeted entering the W-sit (foot placement) instead of escaping it, and seeding the dead point itself was ruled out because it was already visited every episode.
Outcome
Pure configuration: the W-sit (hips externally rotated +/-47 deg, knees folded 110 deg, shins flat, feet beside the body) is a different place from the sagittal squat (feet flat under the COM). The policy's standing skill was bound to a narrow sagittal family, and the wall was confirmed by the interpolation. The foot-placement rungs that followed took prone from 0/159 to 158/159.
Mechanism
A learned skill covers the neighbourhood of the states it succeeded from; a start state outside that neighbourhood fails regardless of height or torque, and an interpolation that stays at zero until close to a working state shows the boundary is sharp.
Applies when
- a policy stalls in a specific posture and several causes are plausible
- deciding between reverse-curriculum seeding and entry-prevention shaping
- a feasibility account says a path exists but the policy does not take it
“**决定性对比:比死点矮 2.7 cm 的蹲姿站立 52.3%,死点 0.0%。** 所以不是高度、 不是力矩(蹲姿族准静态力矩膝 1.96/12、踝 1.24/17,只占 16%)、也不是训练采样 (死点每局被访问 ~9 s)。**是纯位形问题** … 插值实验进一步显示这**不是坡是墙** —— 走到 75% 仍只有 3.1%”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §15 死点位形实验(只读探针,同一个 R0.3 策略放进指定位形) Training at scale 0.4 is NOT the twin of deploying 0.5 at power 0.8 - the algebra matches, the learned policy does not
deploy-scaling-not-training-equivalentNever assume deploy-side scalings can be folded into training-time constants ("burning the crutch into training"): the learned optimum depends on the training-time authority, so treat such conversions as full experiments with pre-registered expectations and a sim2sim gate before any hardware.
Symptom
s1g (S1.6) trained from zero at action_scale 0.4 - meant as the "training twin" of the hardware-proven s1c-at-power-0.8 (0.8 x 0.5 = 0.4) - was all green in Isaac (zero falls, reward 117) yet scored 0/3 across all eight checkpoints and 0/20 at 20 seeds in the MuJoCo gate, falling forward at median 1.57 s with a 2.9x speed overshoot.
Context
The pre-registered expectation (survival gate should pass, since the conviction matrix showed s1c@0.8+delay2 all-survive) was cleanly falsified, and the harness was acquitted by controls: --delay 0 fell identically (not a delay fragility), check_contract all green, and s1c through the same harness survived 2/3. The verdict: "「s1c@0.8 = 0.4 训练孪生」的代数等价不成立" - a policy deployed with a derated output still LIVES in the 0.5 internal model it trained under (its value function, its expectations of its own authority), while a policy that starts training with reduced authority learns a different, clip-hugging gait with zero margin for plant differences ("部署端打折的策略活在 0.5 的内模里,训练起点收权限学出的是贴 clip 的 另一套步态,对 plant 差异零余量"). Result: the policy was withdrawn before hardware ("撤回——不上真机"), the lineage root moved back to the 0.5-contract s1c-5500, and this became the C ladder's cited fact-check ("s1g 是 0/20 证伪出局的那一代").
Change
The amplitude-surgery route abandoned; contract kept at scale 0.5; the deploy-side 0.8 crutch later retired on its own merits when the delay-complete s1e generation ran at full power.
Outcome
One training run bought a clean falsification of a plausible algebraic identity; no hardware time was spent on it because the sim2sim gate caught it.
Mechanism
Output scaling commutes with the network arithmetic but not with learning: the training-time scale shapes which gait solutions are reachable and how much clip headroom the optimum keeps. A derated mature policy retains the wide-authority solution executed softly; a from-zero narrow-authority policy finds a different optimum that saturates its smaller envelope - the two are not the same controller in different units.
Applies when
- proposing to move a deployment derating into a training constant
- a scaled-down contract policy hugs the action clip
- Isaac-green / cross-sim-zero results on a re-scaled lineage
“预注册 a) 证伪——Isaac 全绿(零摔/reward 117)但 MuJoCo --delay 2 八档 checkpoint 扫描全数 0/3、iter6500 20-seed 0/20 … 「s1c@0.8 = 0.4 训练孪生」的代数等价不成立: 部署端打折的策略活在 0.5 的内模里,训练起点收权限学出的是贴 clip 的另一套步态,对 plant 差异零余量。”
train/OMNI_V0_SPEC.md § 3. S1.6 判决(2026-08-07 验收) Design the next run to complete the 2x2 - either outcome then convicts or acquits a factor cleanly
fill-the-missing-factorial-cellWhen two config factors are jointly suspected, lay out the factorial of existing evidence, spend one run on the missing cell with both interpretations and an early-abort tripwire written in advance - and treat either outcome as a verdict, not a disappointment.
Symptom
Hip joints froze at the action clamp in v7, but the history could not say whether the culprit was the raised action_rate (-0.2) or the halved reference amplitude (scale 0.15): existing versions covered only three corners of the (rate x scale) space - v5 (-0.03, 0.30) healthy, v6 (-0.03, 0.15) healthy, v7 (-0.2, 0.15) frozen.
Context
v9 was designed explicitly as the missing cell (-0.2, 0.30), with the readings pre-registered: v9 not frozen -> the real anti-freeze force was always the reference amplitude and -0.2 may stay; v9 frozen -> -0.2 is convicted beyond appeal (freezes at both amplitudes) and the next version goes straight to a structural fix. "两个结局都是干净的信息" - both endings are clean information.
Change
One training run allocated purely to complete the factorial, with freeze tripwires (joint_pos_ref telemetry <0.1 at iter 1000-1500 -> abort, do not run to 6000) so a conviction costs the minimum compute.
Outcome
v9 froze - the rate weight was convicted at both amplitudes ("−0.2 铁案定罪"), and v10 moved to the structural saturation fix with the weight question closed instead of re-litigated.
Mechanism
Three corners of a 2x2 leave the two factors confounded in the failure corner; the fourth observation makes each factor's marginal effect identifiable. Pre-registering both readings turns the run into a guaranteed-informative experiment regardless of outcome.
Applies when
- two config changes are confounded in a failure
- version history already covers some corners of a factor grid
- deciding what single experiment buys the most attribution
“这恰好补齐一个 2×2 实验矩阵的缺格 … v9 不冻 → 真正的抗冻结主力一直是参考摆幅,−0.2 可以留;v9 仍冻 → −0.2 铁案定罪(两种摆幅下都冻),v10 直接上结构修复 … 两个结局都是干净的信息。”
train/WALK_V9_SPEC.md § 0. 设计原则 (2×2 实验矩阵) Before training a one-leg stand, the accounts and a probe showed the default gains could not hold it at all - kp 20 needs 0.39 rad of error to carry the static roll moment, more than the whole adduction range - so per-joint gains came first, and thermal limits set the session length
single-support-gain-authority-probeBefore training a posture that loads one joint statically, compute the steady tracking error load/kp and the series stiffness against m*g*h, and prove with a simple hand-written controller that the posture can be held under the deployment gains - change the gains first if it cannot; then size session length from the thermal account.
Symptom
The one-leg line (standing on one foot, the other folded back, no hopping) had to decide whether the existing gain profile could hold single support before any reward was designed.
Context
Hardware accounts (9.792 kg, COM 0.234 m high, 170 x 80 mm feet, legs 80% of the mass): moving the COM over one foot needs 107 mm of shift and the 20 deg hip-roll adduction range gives 131 mm - geometrically enough. The static frontal moment is 7.8-9 N*m, within RS02's 17 N*m - torque is enough. But at kp 20 carrying 7.8 N*m needs 0.39 rad of tracking error, more than the entire adduction range, and the real robot had already shown it: commanded +0.17, actual -0.04 (0.21 rad droop) under load, 0.0008 rad hanging - load, not the motor. A probe (probe_oneleg.py) then showed open-loop PD cannot hold single support on physics grounds, so the criterion became "an equilibrium exists and a hand-written 4-gain COM feedback can hold it": single-support roll stiffness is hip and ankle in series and must exceed m*g*h_com = 22.5 N*m/rad; ankle kp 12 in series with hip kp 80 gives only 10.4 (open loop 16/16 fell), ankle 60 with hip 80 gives 34.3 (52% margin).
Change
A per-joint gain profile (rl_oneleg: hip_roll kp 80, ankle_roll kp 60, the rest as rl_default) - which needed per-joint gain support in robot.yaml, the bridge, deploy and the trainer's actuator groups - decided before training. Thermal account: single support makes hip_roll the dominant heat load (about 7.8 N*m against a 7 N*m continuous rating), so acceptance and demos run in segments of at most 60 s with a temperature check.
Outcome
Under rl_oneleg the hand-written feedback held six cells cleanly for 6 s (hip_roll steady torque 2.1-3.4 N*m, half the thermal budget); under rl_default the same feedback on the same cells fell 0/4. The trained V0 policy then passed its 40-cell acceptance.
Mechanism
With PD position control, the steady error needed to carry a static load is load/kp; when that error exceeds the joint's range the posture is unreachable whatever the policy does, and series compliance between joints lowers the effective stiffness below the gravity stiffness that single support demands.
Applies when
- single-support, crouched or one-arm-load postures on PD actuators
- a joint "droops" under load on hardware but tracks well when hanging
- deciding whether a new skill needs its own gain profile
“但 kp=20 时撑住 7.8 N·m 需要 **0.39 rad 跟踪误差 > 整个内收行程**。真机已实测: 命令 +0.17 实际 −0.04(droop 0.21 rad),悬挂时 0.0008 rad——是负载不是电机。 … 单支撑滚转是 hip/ankle **串联**刚度,必须 > m·g·h_com = 22.5 N·m/rad;ankle kp12 串 hip80 只有 10.4(开环 16/16 全摔),60 串 80 = 34.3(裕 52%) … **rl_default 同反馈同格 0/4 全摔**(增益档必要性对照)”
git:Lucen V2@origin/oneleg-line:train/ONELEG_V0_SPEC.md § §1-1 单脚站: 几何可行,卡点是 hip_roll 增益权限 / §2 A 线增益 / §5 probe 定谳 The first real-robot get-up was "very violent, kicking on the floor, dangerous" - a sim-perfect policy with no reason to be slow, unbounded absolute targets, no domain randomization and a rate limiter that filtered nothing; the task was restated as "safe, slow, transferable"
first-real-get-up-violent-stage-one-policyDo not put a get-up policy on hardware until its action is bounded (hard bound or state-anchored targets), smoothed, randomized and tested at the real pipeline's latency, and say explicitly that the task is "safe, slow and transferable" - a simulation-perfect policy optimizes only "gets up".
Symptom
On 2026-08-09 the user ran a V0-lineage recovery policy on the real robot and stopped it: very violent, kicking on the floor, dangerous. The planned next rung (a heavier torque_headroom) was never started.
Context
The spec had pre-registered that R0/R1 products stay in simulation and that the real-robot precondition was the R3 smoothing rungs plus a bridge-slew check plus a hanging protocol; the robustness (DR) rungs had not run. In simulation the policy passed 100% with a get-up of about a second. Which ONNX, which gain profile and whether a torque/joint log existed were left "to be recorded later" and never were.
Change
The V0 ladder was stopped at its best product (R3.1, sim only) and a re-rooting proposal was put to the user. The spec's four-layer account: style (the reward pays for standing early and nothing pays for slowness - HumanUP's "Stage I" get-up, "fast but unsafe ... infeasible for real-world deployment"); impact (full-range absolute targets with no hard bound, raw |a| up to 4.77, action saturation 100%, a single-step change of 0.306 saturating hip_pitch); transfer (zero DR, friction pinned at 1.0, the learned leg bracing); link (the bridge's RL slew equals vel_limit, 0.2-0.66 rad per step, while the real pipeline has 1-2 steps of time-varying latency and acceptance ran at delay 0).
Outcome
The line was re-rooted twice (training-side rate limit, then the beta-anchored action space) and gained a hang protocol before the next real attempt; on 08-11 a beta-anchored policy produced the line's first real get-up.
Mechanism
A task reward that pays for standing early selects the fastest feasible get-up; with absolute full-range targets every large target jump is a torque impulse bounded only by the clip; zero DR and braced-leg solutions do not transfer; and a limiter set at the velocity limit does nothing at 50 Hz.
Conflicts
The four layers are the spec's reconstruction from simulation probes and the literature; the real run's policy file, gain profile and log were never recorded, so no layer was confirmed against hardware data.
Applies when
- a first hardware trial of a high-effort skill is being scheduled
- sim success is high but the policy saturates actions or torques
- pre-registered hardware preconditions are not all met
“用户真机反馈:**非常猛、地上乱踢、危险**,叫停(R3.3 torque_headroom 加档已选型 weight −0.5→−1.5,未启动)。真机细节(哪个 onnx、什么档、有无 τ/q log)**待补记** … 任务从"能起来"变成 **"安全、慢、可迁移"** … **链路层**:桥层 slew RL 档 = vel_limit(10/20/33 rad/s ≈ 每拍 0.2~0.66 rad), 对 recovery 形同虚设;真机 1~2 拍时变延迟,验收默认 delay 0。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §26 真机叫停与换根判决(2026-08-09) Never referee a suspect metric with another metric from the same code - they can share the disease
independent-referee-for-metric-disputesTo adjudicate a disputed measurement, compute the quantity by an independent method from raw state; never accept a sibling column from the same pipeline as the tiebreaker.
Symptom
A triple reversal on one question: sidewalk sign diagnosis (correct) was retracted using a second metric from the same script, then the retraction itself had to be retracted when that second metric turned out to be the buggy one - two opposite-direction errors on the same problem in one day, both written into the execution sheet.
Context
The probe's net-displacement metric suggested the sidewalk reference sign was inverted. Worried about yaw-drift pollution of net displacement, the author checked the same table's body-frame vy_mean column (~0.003 everywhere, 20-50x smaller) and retracted the sign diagnosis. But vy_mean came from mj_objectVelocity, which was silently reporting vertical velocity due to a frame bug - the "referee" was the diseased measurement. Re-measured with a truly independent computation (xmat.T @ qvel, world trajectory), the original diagnosis was confirmed: saw -0.5 gave vy +0.058/-0.130 (76%/106%), consistent with the net-displacement values all along (yaw pollution was real but only 10-21 deg, nowhere near reversal-sized).
Change
Lesson written twice, verbatim, as a hard rule: when questioning a measurement, the referee must be an independent algorithm (different code path, different physical derivation), e.g. rotate qvel by the body matrix directly, or inspect the raw world trajectory.
Outcome
With the independent referee in place the frame bug was confirmed, fixed, and the whole C4 line re-scored - revealing sidewalk had been working (see body-frame-velocity-api-audit).
Mechanism
Metrics sharing a code path (or an upstream API) share failure modes; agreement between them is evidence about the code, not the world. Only a measurement with an independent derivation can break the tie, because its errors are uncorrelated with the suspect's.
Applies when
- two metrics of the same quantity disagree
- about to retract a conclusion based on a second readout
- auditing evaluation code after a surprising result
“我用一个坏指标去质疑一个好指标,并把撤回写进了执行单。教训(写死):质疑一个测量时,不能用同一份代码里的另一个测量当裁判 —— 它们可能同源同病。裁判必须是独立算法(这次的裁判应该一开始就是 xmat.T · qvel[:3],或直接看世界轨迹)。”
train/C_LADDER_RUN.md § 3m. 二 我今天犯了两个方向相反的错 / 3n. 五 元教训 The median of a bimodal metric lands in the empty gap - check the distribution, and never judge swing on 3 seeds
median-hides-bimodal-distributionBefore quoting a median or mean, look at the distribution; report suspected-bimodal metrics as mode share plus per-mode ranges, use small-seed smoke runs only to screen trends, and size the seed count for decisions by the share resolution you need (here: 20).
Symptom
Years of "high swing variance" and undecidable 3-seed swing readings turned out to be one fact: the metric was bimodal all along - "历代 swing 高方差与 3-seed 不可判由此定性:一直在测双稳态系统" - and every median reported from it (e.g. 12.1 mm) described a value no seed ever produced.
Context
Concrete instances: s2e_pd-1400's 20 seeds split 2.6-4.9 mm vs 19.3-24.0 mm with zero seeds between; s1e-500 read 3.9 mm on seeds 0-2 but 23.1 mm median over 20 seeds; a 3-seed reading of 19.3 was logged as "double-peak optimism, lesson recurrence #4". The selection re-audit codified the sampling rule: "3-seed 的 swing 读数不可判点, 只能筛带,选点必须 20-seed" - 3 seeds may screen a band, only 20 seeds may pick a point.
Change
Swing (and any suspected multi-modal metric) reported as mode shares plus per-mode ranges instead of a bare median; 3-seed smoke numbers demoted to band-screening; all shipping/selection decisions moved to 20-seed batteries.
Outcome
The "swing debt" bookkeeping was reinterpreted as basin probability (see swing-bistability-damping-switch), and checkpoint selection stopped being whipsawed by which basin the first three seeds happened to fall into.
Mechanism
Central-tendency statistics presuppose unimodality; on a bimodal distribution the median tracks the mode SHARE, not any achievable behavior, and small samples alias the share entirely. Mode-aware reporting (share + per-mode stats) is the only faithful summary, and the needed sample size is set by the share resolution required.
Applies when
- a quality metric shows chronic high variance across seeds
- 3-seed smoke readings contradict 20-seed batteries
- reporting swing height, clearance, or any basin-prone metric
“中位数落在空档里,「swing 债 −11mm」实为「50% 概率掉进拖地吸引子」。历代 swing 高方差与 3-seed 不可判由此定性:一直在测双稳态系统。… swing 跨 seed 双峰 (500 在 seed0~2 只读 3.9mm, 20-seed 中位 23.1) —— 3-seed 的 swing 读数不可判点, 只能筛带, 选点必须 20-seed。”
train/README.md § swing 双稳态定性 / s1e 选点重审 The advisor's "runtime five-stage state machine + per-stage reference poses + RL residual" appeared in none of the three papers it cited - reading the originals changed the plan and downgraded two widely repeated industry claims
advisor-paraphrase-vs-paperRead the primary source behind any piece of advice before adopting its architecture; record where the paraphrase and the original differ, downgrade claims the originals do not support to speculation, and adopt what the verified sources actually share.
Symptom
After the violent first real run, an advisor proposed re-architecting recovery as a runtime staged state machine with reference poses and an RL residual, citing HoST, HumanUP and StableMimic.
Context
The three papers were read in full on 2026-08-09 and tabulated (deployment form, what the "stages" really are, hard constraints, references). HoST: one end-to-end policy, height-gated rewards in training, action anchored as q + beta*a with a beta curriculum. HumanUP: two training stages with the same observation/action; the vendor's three-stage state machine is the baseline it beats (41.7% vs 78.3%); Stage II tracks an 8x slowed Stage I trajectory (4x too violent, 10x does not converge). StableMimic: a learned soft gate. On 08-10 more sources were checked the same way: the Agility page does not say Digit's self-righting was learned in simulation (only step recovery is stated as RL), so the claim was downgraded to speculation; HoST's support for the 12-DoF armless Mini Pi exists in its code repository, not in the paper text.
Change
Adopted only what the originals share: a hard action bound or anchored action space, strong smoothing including a second-difference term, a slowed hidden reference, heavy DR and real fallen states. The staged runtime state machine was not adopted.
Outcome
The next re-rooting candidates came straight from the verified material, and the beta-anchored action space (HoST, with the Mini Pi configuration as the nearest real-robot precedent) became V2, the lineage that later stood up on hardware.
Mechanism
A paraphrase compresses a paper into the advisor's own architecture; only the original shows what was actually deployed, what was a baseline, and which numbers came with which ablation.
Applies when
- an advisor, agent or summary proposes an architecture with citations
- an industry claim ("X learned it in sim") is about to justify a design
- several papers are cited for one combined recipe
“⇒ **顾问的核心形态"runtime 五阶段状态机 + 每阶段参考姿态 + RL residual"在三篇引文 里均不存在**,其中 HumanUP 还点名 state machine 是局限。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §26 三篇引文精读判决(2026-08-09 全文核对;顾问转述与原文有出入) Anchoring the action on the measured joint angle (target = q + beta*a), with a beta curriculum down to tau_limit/kp, bounded torque by construction, removed the re-falls and later stood the robot up on hardware
beta-anchored-action-targetFor large-motion skills on position-controlled actuators, bound the action relative to the measured joint angle with a per-joint authority of tau_limit/kp, curriculum the authority down from full range, keep the curriculum state out of the observation and pin acceptance at the deployed authority - and make the deployment code refuse to run the anchored contract without a measured q.
Symptom
The V0 full-range absolute action produced violent targets; the V1 command-anchored rate limit made standing oscillate. Both failure modes came from how the action becomes a target.
Context
V2.0 (user approved, from scratch): BetaAnchorJointPositionAction, target = q_measured + beta_j(m)*a, memoryless per step. beta_j(m) = floor + m*(beta0 - floor), beta0 = the contract half-range (m = 1 reproduces V0 authority), floor = min(tau_limit/kp, beta0): hip_pitch 1.309 -> 0.40, knee 1.047 -> 0.40, hip_yaw -> 0.917, the other joints unchanged - the tightening lands exactly on the joints the V0 torque account convicted. m drops 0.1 per step when a standing-share EMA exceeds 0.35. beta is NOT in the observation, so the 45-dim contract is untouched; acceptance is pinned at m = 0 because the Python curriculum state is not saved in the checkpoint. The deployment chain got a new profile (recovery_v2: action_anchor current_q, explicit per-joint beta written into the contract, independent of the gain profile), and policy_io raises if q is missing rather than silently falling back to the absolute contract; the old profile's check reproduced its pre-change deviation bit for bit.
Change
New action term and beta curriculum; later the RS06 floor was lowered 0.40 -> 0.30 -> 0.25 (kp*beta 7.5 N*m) and the stamped deployment profile was synced to 0.25.
Outcome
First acceptance at m = 0 (v2_0b): re-falls 0% in every category, the torque gate passed for the first time on the line (worst 69.9%), knee jitter 0.004; supine 98.8 / side 88.8% with prone and mid still failing (fixed by the conditional pull curriculum). MuJoCo showed demand at or under the limits (hip_pitch 11.7/12 against V0's 26.8). Lowering beta cut impact (hip_pitch demand 9.7 -> 8.5 N*m) but barely slowed the get-up - it had become coordination-limited. Enabling the policy moves the target only +/-beta around the current pose, so there is no homing fling; the 08-11 real get-up and the later v3_1p1c both run on this contract.
Mechanism
kp*beta caps the proportional torque in a single step with no build-up delay and no memory, giving both a hard impact bound and full balance bandwidth.
Applies when
- a skill needs full joint range but hardware torque limits are low
- absolute position targets cause impacts or saturation
- changing the action semantics of a contract that deployed policies share
“**动作项** `BetaAnchorJointPositionAction`:`target = q_实测 + β_j(m)·a`, 逐步无记忆 … **Play/验收钉 m=0(= floor = 部署档)**:python 课程状态不进 checkpoint, Play cfg 显式 `beta_m_start=0` … 判读:**结构赌注兑现** —— 站姿零再摔 + 力矩账首过(kp·β 封顶按构造)”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §33 V2.0 预注册(2026-08-10,用户点头开工):β 锚定动作空间,从零训 The deploy-side walk/recovery switch - into recovery at tilt > 65 deg held 0.3 s, back at tilt < 15 deg with angular rate < 1 rad/s and straight knees held 1 s, a 15 s timeout, last action cleared both ways - and the handoff steps the design required are only partly implemented
walk-recovery-fsm-handoffSpecify a deploy-time controller switch as hysteretic, time-filtered predicates the robot can measure (proxy what it cannot, e.g. straight knees for height), a timeout that ends in a safe stop, and a complete handoff (history, clock, last action, command ramp) - then test that the code performs every handoff step, because the design document is not the implementation.
Symptom
With a recovery policy and a locomotion policy as separate networks, the robot needs a switch: when is it "fallen", when is it "up", and what state must be reset so the next policy does not act on the previous one's history.
Context
The 08-09 design: enter recovery when fallen (tilt > 55 deg or height < 0.60 x 0.384 m) for 150 ms, leave for a stand-hold when upright (tilt < 12 deg, height > 0.85 x 0.384 m, feet steady, |omega| < 0.8) for 400 ms - wide entry, strict exit, hysteresis - then a mandatory handoff trio before walking resumes (reset the walking policy's observation history, restart its phase clock at 0, clear its previous action and latency buffer) and a command ramp instead of a jump. The 08-14 implementation in deploy_policy (--recovery-policy): each policy under its own manifest contract (walk: nominal + scale; recovery: beta-anchored), the same rl_default gains, the tilt cutoff disabled; RECOVERY at tilt > 65 deg for 0.3 s; LOCO again at tilt < 15 deg and |omega| < 1 and knees straight (< 0.35 rad) for 1 s - the robot's computer has no height estimate, and straight knees stand in for height so a V3.0-style upright kneel cannot pass as standing; RECOVERY longer than 15 s ends in a safe stop; last_action cleared on both switches; command forced to 0 during RECOVERY; power scaling applies to LOCO only.
Change
An open account was written down with it: the recovery end state (0.355 m stance, hip yaw -/+27 deg) is outside the walking policy's training start distribution, so the first test must use stand / zero command as LOCO, and the long-term fix is to widen the walking policy's initial states rather than bend recovery's stance to suit walking.
Outcome
The spec records only a successful compile (py_compile); the hang test was left to be done on site. The operator runbook carries the three-step procedure (hang with stand as LOCO, mat and push, then omni walk as LOCO) but no outcome.
Mechanism
Two policies trained separately each assume their own history, clock and last action; a switch that carries any of them across feeds the next policy a state it never saw - the design called this "the walking policy seeing a ghost history".
Conflicts
The 08-09 design requires resetting history, clock and previous action plus a command ramp; the 08-14 implementation records last_action clearing and a zero command during recovery; the one-leg spec of 2026-09-14 lists the handoff hygiene as specified but not implemented - reset_history() is called by nothing (a 215-dim policy would carry four frames of pre-fall history), the phase clock is not zeroed, and there is no command ramp back to LOCO. No hardware run of the FSM is recorded in either source.
Applies when
- switching between separately trained policies on hardware
- a policy with history or phase observations is re-enabled mid-run
- the robot lacks a sensor the switching criterion was designed around
“**判据**:进 RECOVERY = 倾角 >65°(`--fall-tilt-deg`)持续 0.3 s;回 LOCO = §5 真机可测子集:倾角 <15° ∧ |ω|<1 ∧ **膝直 <0.35 rad(NX 无高度观测, 高度门用膝直代理 —— 防 V3.0 型"跪坐但直立"误判)** 持续 1 s (`--recover-hold`);RECOVERY 单次 >15 s(`--recovery-max-time`)安全停。 … **切换卫生**:两向切换 last_action 清零;RECOVERY 态 cmd 强制 0”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §50 FSM 双策略调度(2026-08-14,用户令):deploy_policy --recovery-policy Freeze the deployment contract, stamp every export, and let an automated checker catch wiring bugs
contract-freeze-and-checkerFreeze and fingerprint the policy I/O contract; ship contract changes as new versioned profiles that leave old artifacts bit-identical; and extend the automated contract checker with every pipeline change, forcing the new path to execute in the check.
Symptom
Contract-level changes (observation layout, action pipeline) are where silent sim/real divergence is born; two real wiring bugs appeared the one time the action pipeline was extended.
Context
The 215-dim observation contract was frozen ("纪元 3,三机 digest" - an era number plus a digest agreed across three machines); proposals that would break it (e.g. a GRU memory) were rejected on contract grounds. Every exported ONNX is stamped and verified with a manifest (onnx_manifest --stamp / --verify), and deployment refuses mismatched combinations. When C4 added the lateral feed-forward, it went in as a NEW profile (omni_ff) leaving the existing omni profile's behavior bit-identical; the checker (check_contract) was extended to force the feed-forward path to actually execute (cmd_vy=0.13) and promptly caught two genuine bugs: (1) re-clamping with soft_joint_pos_limits after the feed-forward (0.23 rad deviation) instead of reusing the parent's clip; (2) indexing processed actions by asset.joint_names instead of the action term's own contract-ordered _joint_names, which landed the feed-forward on the wrong joints (l_hip_yaw / r_ankle_pitch).
Change
Contract discipline as implemented: frozen dims + digest; manifest stamping and refusal; contract changes only via new versioned profiles; checker updated in the same commit as any pipeline change, with inputs chosen so new code paths are exercised.
Outcome
Both wiring bugs caught before any training or deployment ("两个都是 check_contract 当场抓出来的 —— 这次它值回票价"); old deployments provably unaffected by the new profile.
Mechanism
The contract is the only interface the policy and robot share; freezing plus fingerprinting makes divergence detectable, and an executable checker turns "the contract holds" from a belief into a test - but only if its inputs actually drive the new code path.
Applies when
- modifying the action or observation pipeline of a deployed policy
- exporting policies for hardware
- proposals that would change observation dims or history structure
“契约校验抓到的两个真错误(记账,别再犯):1. 前馈后误用 soft_joint_pos_limits(URDF 限位 ×0.9)重钳 → 0.23 rad 偏差 … 2. 用 asset.joint_names 索引 _processed_actions → 前馈落到 l_hip_yaw/r_ankle_pitch 上 … 两个都是 check_contract 当场抓出来的 —— 这次它值回票价。”
train/C_LADDER_RUN.md § 3j. 契约级改动 / 契约校验抓到的两个真错误 Run acceptance under measured contact parameters - honest condim/torsional-friction flipped a false PASS into a real-matching FAIL
eval-plant-honesty-contact-paramsPin the evaluation plant's contact model to measured values (contact dimension, torsional/rolling friction, mu) before trusting any gate that involves slip, impact, or drift - a gate can only fail a policy for physics its simulator contains.
Symptom
walk_v5 passed the old acceptance battery yet failed on the real robot (footfall force, drift, kicking) - the evaluation plant was flattering the policy.
Context
The battery was re-run under "honest contact parameters" - condim 4 (adding torsional contact) with measured torsional friction 0.035 - and v5 then FAILED exactly the rows corresponding to its real problems: heading 185 deg (limit 30), support-foot yaw slip 284 deg (limit 80), landing force 1.72x (limit 1.5x), suspended tilt 45.9 deg (limit 10). The slip physics depends on torsional friction, which the default contact model (condim 3) does not even simulate - a slip problem is invisible to an evaluator that cannot represent yaw friction at the foot. Term-sizing measurements for the new rewards were likewise taken under the same honest parameters (cmd 0.45, skipping the 5 s start transient).
Change
Acceptance harness pinned to condim 4 / torsion 0.035 (measured); verdicts issued under defaults declared non-citable for these rows.
Outcome
Sim acceptance verdicts began agreeing with hardware ("现在失败, 与真机一致"); the v6 fixes could be developed and validated against an evaluator that could actually see the disease.
Mechanism
An evaluator is a plant model too: contact dimensionality and friction values decide which failure modes exist in the simulation at all. Evaluating under default contact parameters tests the policy in a world where its real failure is physically impossible, producing structurally false PASSes.
Applies when
- sim acceptance passes policies that fail on hardware
- slip/drift/impact gates run under default simulator contact settings
- setting up a cross-simulator evaluation harness
“accept_v2.py 已加三条判据, walk_v5 在诚实的接触参数下(--condim 4 --torsion 0.035)现在失败, 与真机一致:直行 15s 航向累计 <30° | 185° ✗ … 落脚力峰值 <1.5× 体重 | 1.72× ✗”
train/WALK_V6_MINIMAL.md § 5. 验收 Three hardware accounts locked the run design point - and the knee's real speed ceiling is tau_limit/kd, not the firmware limit
feasibility-accounts-lock-design-pointBefore opening a dynamic-gait training line, compute the full account set - tau_limit/kd effective speed ceilings, joint ROM under the intended reference geometry, and thermal RMS at the duty cycle - and let the accounts lock the design point; move only to pre-registered in-table alternates, re-running the accounts first.
Symptom
The run line was believed to require a firmware raise of the RS06 speed limit (10 rad/s) as a hard precondition, and the feasibility script's motor-envelope scan had marked 80/100 mm foot-lift cells "physically feasible".
Context
Three added accounts re-decided everything. (1) Damping tax: in MIT mode tau = kp*(q_des-q) - kd*qd, so sustained rotation is capped at tau_limit/kd = 12/1.5 = 8 rad/s - below the firmware's 10; at peak speeds 6.7-7.9 rad/s the damping term alone eats 10.1-11.9 N*m (84-99% of the torque limit). "提固件 limit_spd 越不过这道税 —— 它是 kd 与限扭的比,不是固件旋钮." (2) Joint ROM: the feasibility script had checked motor envelopes but NOT joint range - the ankle-pitch ROM caps 1:2:1 leg-shortening lift at 62 mm (soft) / 77 mm (hard), so the 80/100 mm "feasible" cells were voided; also firmware-independent. (3) Ankle thermal: duty 0.40 puts ankle RMS at 87% of continuous rating (0.35 -> 93%); long-period big-stride cells hit both ankle torque peak and heat. Verdict: firmware raise DEQUEUED (50 mm design point needs knee 6.7-7.3 < the 8 rad/s effective ceiling < firmware 10); vel_limit stays 10 so sim == robot. The three accounts uniquely lock the design point - 50 mm lift / T 0.60 s / duty 0.40 - "三笔账 唯一锁定,不是调参空间", with pre-registered alternates allowed only inside the table and only after re-running the accounts.
Change
Design point frozen from accounts; hardware precondition reversed by arithmetic rather than by test; reference amplitude (0.84 rad = FK inverse of 50 mm) derived, per-joint action scales sized to the required travel (knee 0.9, hip_pitch 0.6, ankle deliberately NOT amplified - hard limit is adjacent).
Outcome
A firmware work item left the critical path; an infeasible region of the design space was closed before any training; the remaining risk (knee tracking lag from the damping tax) was pre-registered with its own criterion and in-table fallback (duty 0.35) - "这不是'奖励没调好', 是 plant 账".
Mechanism
PD actuators in MIT mode pay kd*velocity out of the same torque budget that tracks position, so the effective speed ceiling is a ratio of configuration constants, invisible to firmware settings; and feasibility is the intersection of ALL constraint families (torque envelope, joint ROM, thermal RMS) - a scan that omits one family certifies impossible cells.
Applies when
- planning running/jumping or any high-rate gait on PD actuators
- a firmware or hardware upgrade is assumed as a training precondition
- a feasibility scan covers motor limits but not ROM or heat
“膝的有效速度顶 = τ_limit/kd = 12/1.5 = 8 rad/s,不是固件的 10。… 提固件 limit_spd 越不过这道税 —— 它是 kd 与限扭的比,不是固件旋钮。… 可行性脚本只查了电机包络没查关节 ROM —— 其 80/100mm 的"物理可行"格作废。… 判决:RS06 提固件对 run v0 不是前置,出队”
train/RUN_V0_SPEC.md § 1. 硬件账判决 / 2. 步态设计点 Deployment power derating damages non-forward axes far more than forward - sweep it in sim before deploying
power-scale-hurts-nonforward-axesTreat deployment power/torque scaling as a plant parameter: evaluate the policy in sim at the exact deployment scale, expect non-dominant axes to degrade first under derating, and either deploy at the training power or train with power randomization.
Symptom
Policies deployed at power-scale 0.8 (a safety derating of commanded torque) looked fine walking forward but were weak at backward and turning, inviting the wrong diagnosis "the skill was not trained well".
Context
Measured repeatedly: on s1e, going 1.0 -> 0.8 cost forward 18% but backward 58%; on C4-ff800, turn tracking was +25%/+40% at pw0.8 vs +75%/+58% at pw1.0, backward 51-52% vs 97-103%, while forward stayed 96-98% at both. Sim evaluation numbers in the plan were all pw1.0, but the robot was being run at 0.8.
Change
Pre-deploy protocol added: sweep the exported policy across power in sim (for PW in 0.8 0.9 1.0: eval_c_matrix --power $PW --seeds 20) and deploy at the first level where both turn directions reach >=50%. For C4 the recommendation was raise the robot to pw1.0 - the sweep showed it nearly free (saturation 47%->33%, left foot-clipping danger zone 25%->6%, cost only tilt 6.7->8.3 deg).
Outcome
Turning "weakness" resolved without any retraining; the sim sweep correctly predicted the real-robot signature at both power levels.
Mechanism
Forward walking is the reward-dominant, torque-cheapest skill with the most margin; backward/turn/sidewalk live closer to the torque envelope, so a uniform torque derating consumes their margin first. Training ran at power 1.0 (the trainer does no power scaling), so deploying at 0.8 is a systematic underactuation the policy never experienced.
Applies when
- deploying with any torque/power derating or safety scale
- secondary skills (backward, turn, lateral) underperform on hardware while forward walking looks fine
- choosing the deployment power level for a new policy
“power 衰减对非前进轴的伤害远大于前进轴(s1e:前进 1.0→0.8 掉 18%,后退掉 58%)。转向是非前进轴,0.8 下很可能明显跟不动。”
train/C_LADDER_RUN.md § 3c. A-2 上机前先定部署力度档 / 3p. 二 Fall recovery was defined as the whole chain - any fallen pose, a stable stand, a clean hand-back to walking - and built as a second policy behind a deploy-side switch, not folded into the walking PPO
recovery-two-policies-and-a-state-machineDefine a recovery skill by the whole chain it must complete, including the hand-back to the next controller; if it is built as a separate policy, make the switching logic and its handoff contract a deliverable of their own, and keep the recovery observation contract a subset of the locomotion one so a unified policy stays possible later.
Symptom
A walking robot that falls needs a human to stand it back up. The design question on 2026-08-09 was whether to teach getting up inside the existing omni walking policy or beside it.
Context
The user set the goal as "any fallen pose -> stand up alone -> stand stably", and the spec named the real difficulty as the full chain fall -> recovery -> stable stand -> correctly initialised walking history and clock -> walking, making the deploy state machine a first-class deliverable. A unified single policy had a real-robot precedent (arXiv:2605.18611, a state-dependent gate near 37 deg tilt) but was deferred until a recovery policy and an omni policy were each reliable. The line ran on its own branch and worktree with every walk/stand/omni/run config path untouched. The development path copied the G1 learned get-up logic (arXiv:2502.12152): first find any feasible get-up (ugly accepted), then add smoothing, torque and real-robot constraints. The recovery contract kept the base 45-dim observation (command slice held at 0, no gait phase, no frame history - their reasons do not apply to a skill without a clock or a velocity task), so it stays a prefix of the 215-dim omni contract and a later merge is not foreclosed.
Change
Two policies and a deploy-side switch instead of one retrained walking policy; recovery got its own minimal contract (45 dims, full-range action, later the beta-anchored profile) and its own acceptance battery.
Outcome
The split held for the whole line: on 08-14 deploy_policy gained a second (PolicyIO, ONNX) pair behind --recovery-policy, each loaded under its own manifest contract, and the runbook runs stand_v1b or omni_c4_ff800 as the locomotion side with recovery_v3_1p1c. The literature scan of 08-10 found that every verified get-up implementation deploys one end-to-end policy (or softly gated experts) and stages only on the training side - so the runtime state machine here is the walk/recovery switch, not a staged get-up.
Mechanism
A separate policy keeps each reward table single-purpose and lets a proven walking lineage stay byte-frozen; the cost moves to the handoff, where every piece of state one policy leaves behind (history, clock, last action, command) must be reset for the other.
Applies when
- adding fall recovery or get-up to a robot that already walks
- choosing between one unified policy and a switched pair of policies
- designing the observation/action contract of a secondary skill
“先做 recovery policy + omni policy 两个策略,部署侧状态机切换;不把 recovery 硬塞进现有 omni PPO。 … 任务定义:**任意跌倒姿态 → 自己站起来 → 稳定站立**。真正的难点不只是"起身", … omni walk**(§6 部署状态机是本 spec 的一等公民,不是附录)”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §0 目标口径与架构判决(用户 2026-08-09 定) Choose the fork root by which candidate's shortfalls are recoverable, not by headline score
fork-root-recoverable-shortfallWhen picking a checkpoint to fork from, rank candidates by whether their weaknesses are trainable-back, not by current headline metrics; prefer the candidate whose deficits the upcoming training directly pays for.
Symptom
Multiple candidate checkpoints for the omni-command ladder root, each best at something different: fric-3000 had the best tracking precision (vx 88-91%) and hardened plant robustness; s1e-500 had lower precision (vx 82%) but was the only candidate that could still walk backward.
Context
Root selection ran as a data probe, not a preference vote: 6 candidates x 8 out-of-distribution omni commands x 20 seeds = 960 cells (probe_omni_0808.json). s1e-500 @pw1.0 survived 20/20 in all eight conditions including backward at 67% tracking; the deep-trained fric lineage scored backward 0-3/20 despite better forward precision.
Change
Decision criterion made explicit: list what each candidate exclusively wins at, then ask which of those wins the loser could train back. fric-3000's exclusive wins (precision, plant robustness) are both retrainable - precision is directly optimized by the reward, plant hardening is a planned later pass. s1e-500's exclusive wins (backward plasticity 20/20 vs 2/20, disturbance margin 159/160 vs 125/160, push chirality symmetry 40/40 vs 17/40) had all been shown unrecoverable - push-level rungs failed twice, chirality never recovered even with mirror augmentation on. Root = s1e-500.
Outcome
s1e-500 carried the whole C ladder; its backward skill was preserved through C2/C4 gates (regress budget <=2/20 enforced), and the final C4 product passed a 260-cell battery at 20/20 everywhere.
Mechanism
Training can re-earn anything the objective directly pays for, but capabilities that earlier training destroyed and never restored (plasticity, symmetry, robustness margins) are empirically one-way doors. The information-bearing comparison is therefore recoverability of each candidate's deficit, which the team stated as "独占项的可恢复性正好相反 —— 这就是判据" (the exclusive items' recoverability is exactly opposite - that is the criterion).
Applies when
- selecting a resume/fork root among several checkpoints
- one candidate is more precise but another retains a skill the rest lost
- planning a task-extension ladder from an existing lineage
“fric-3000 赢在精度(vx 88~91%…)与 plant 鲁棒性 → 两样都训得回来…;s1e-500 赢在可塑性(C1 20/20 vs 2/20)、抗扰余量(159/160 vs 125/160)、手性对称(推 ±6 N·s 40/40 vs 17/40)→ 三样都训不回来 … 独占项的可恢复性正好相反 —— 这就是判据。”
train/C_LADDER_RUN.md § 0. 为什么根是 s1e-500(数据,不是偏好) A single-signal contact detector lied in both directions - foot height flagged 40% false flight on a walking gait, contact force alone flagged false flight during low-friction slip - so flight became force < 5 N AND sole height > 5 mm
contact-detector-single-signal-liesDefine contact and flight events from two independent signals (force and geometry) in conjunction, validate the detector on a behaviour known not to contain the event before using it as a gate, and match the trainer's threshold when comparing across simulators.
Symptom
The run line needed a flight-fraction gate. The first MuJoCo version, "sole higher than 2 mm", measured 40% flight on a walking policy that never flies. Five weeks later the one-leg gate, using contact force alone, reported support-foot "flight" segments at mu 0.4 for a policy that was not hopping.
Context
During a walking step the toe lifts or the heel strikes with the foot pitched, so the ankle-roll origin rises a few mm while part of the sole still touches - height alone calls that flight. Switching to contact force < 5 N (the same threshold Isaac's contact reward uses) zeroed the false flight on walking. In the one-leg re-test every force-only "flight" segment had a measured sole height of 0.0 mm: the normal force chattered while slip corrections played out on low friction.
Change
Run line: flight = contact force < 5 N ("lift-off must be judged by contact force"). One-leg line (2026-09-16): flight = force < 5 N AND sole height > 5 mm, recorded as the same measurement lesson in the opposite direction; the gate's behavioural meaning was unchanged.
Outcome
With force-based detection the walking policy read 0.0 flight and the run policy's zero flight was confirmed by two plants; with the conjunctive definition the one-leg support-foot gate stopped reporting false hops.
Mechanism
Each signal has its own failure: geometry moves without leaving the ground (foot pitch), and forces drop without leaving the ground (slip chatter); requiring both removes both families of false positives.
Applies when
- writing a flight, lift-off, hop or slip detector for a gate
- a gate reports an event the video does not show
- reusing a detector on a different gait or floor friction
“首版用**足底高度>2mm** 判离地, 在 omni_s1e 走路策略上测出 40% 假腾空 … 改用**接触力 <5N**(与 Isaac feet_contact_number 同源阈值)后 空检归零 (walk 策略 flight_frac 0.0)。**课文: 离地判定必须用接触力, 高度判 会把脚的俯仰当腾空**”
train/README.md § run R1 立项 (2026-08-09): Mac 侧新工具 + 一次空检抓获 The fallen-state reset was designed, not sampled from SO(3) - fixed category shares with jitter, a low drop that settles physically, equal left/right shares for mirror augmentation, and a numeric check before training
fallen-pose-reset-distributionBuild a fallen-start distribution from named, physically plausible categories with jitter and a settle phase, keep mirrored categories at equal probability, and check the realized shares and penetration numerically before spending a training run on it.
Symptom
A get-up policy can only learn from the fallen states its resets produce; uniformly random orientations produce ground-penetrating and limit-jammed states the robot can never be in.
Context
R0 reset_root_fallen: supine 30%, prone 30%, side_l 15%, side_r 15%, mid (random axis 50-125 deg) 10%, +/-15 deg jitter, full yaw, dropped from 0.28-0.40 m and left to settle under physics, joints uniform inside the soft limits with a 5% margin plus small random velocities. Random SO(3) was rejected (the advisor agreed). side_l and side_r must have equal probability because mirror augmentation turns a left fall into a right fall. The advisor had proposed supine and prone only for R0; the spec included side and mid because the feasibility accounts showed physical solutions for all of them, and wrote "narrow back to supine+prone" down as the first fallback. With no display on the training box the reset was checked numerically instead of by eye.
Change
Category mix as above; realized shares, settle height and penetration measured over 512 envs before the first run. A fallen-state bank (real falls, settled and stored) was pre-registered for R2.
Outcome
Realized shares 29.3/31.6/16.4/17.8% against the config, settle +0.262 m, final penetration 0/512 (a 0.10 m peak at the write instant, ankle links only, pushed out within 80 ms because the 0.28 m drop floor is shorter than a fully extended leg). R0's failure was a reward basin, not a reset artifact. The fallen-state bank stayed unbuilt through V3.1 (checklist item open); R0.3 later re-sliced the prone share into roll_l/roll_r bands, which is what forced the acceptance distribution to be frozen separately.
Mechanism
A category-structured, physically settled start distribution keeps training on states the robot can actually occupy, and equal mirrored shares keep mirror augmentation a pure doubling of data rather than a bias.
Applies when
- designing reset distributions for get-up, recovery or multi-contact skills
- mirror/symmetry augmentation is on and the task has chiral start states
- no viewport is available to inspect resets on the training machine
“角度 jitter ±15°、yaw 全域、0.28~0.40 m 低空放下由物理沉降,关节软限位内 均匀(留 5% 余量)+ 小随机速度。**不用 random SO(3)**(会采出穿地/极限卡死 等现实不可能状态,顾问同判) … side_l/side_r **概率必须相等**(镜像增强的样本同分布前提)”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §3 R0 任务定义 / §9 核查单 A suspended (no-load) test acquits or convicts the actuator before you blame authority
suspended-test-isolates-actuator-authorityBefore attributing a failure to actuator authority, measure no-load tracking error and steady-state torque fraction; blame authority only if the task fails while the error grows with demanded force - and then fix gains or targets, not training.
Symptom
hip_roll sagged 0.21 rad on the ground and saturation questions loomed over the sidewalk plan - was the roll axis physically too weak (authority), or was something else limiting it?
Context
Before C4, the roll-authority question was settled by measurement triage: suspended test (--suspend, feet off ground) showed hip_roll tracking error 0.0008 rad - actuator acquitted; the entire 0.21 rad ground sag is load-induced. Steady-state torque was 25% of limit - 75% margin remains. Since sidewalk needs lateral force, not exact angles, authority was ruled "not a hard limit", with a pre-registered criterion for when it WOULD become one: sidewalk fails to track AND roll error keeps growing - then the fix is raising hip_roll kp or lowering the vy target, not more training.
Change
Hypothesis "roll authority insufficient" demoted from blocker to a monitored branch with an explicit trigger condition; C4 proceeded.
Outcome
Later open-loop probes confirmed the actuator could produce the behavior (sidewalk feed-forward ran at full amplitude, 5/5 survival), and the eventual C4 failure causes were measurement and reward, never authority.
Mechanism
Suspended vs loaded comparison separates the actuator's closed-loop competence from the load path: tiny no-load tracking error means the motor/controller is fine and any loaded deviation is statics (gravity / stiffness budget, kp trading error for force). Torque-fraction measurement then bounds how much force headroom actually remains.
Applies when
- suspecting an axis is "too weak" for a new skill
- large position sag on a loaded joint
- deciding between hardware fix, gain change, and more training
“吊挂(--suspend)实测 hip_roll 跟踪误差 0.0008 rad → 执行器无罪,地面下垂 0.21 rad 全是负载所致;稳态占限扭 25% → 仍有 75% 扭矩余量。… 判据:若 C4 出现「侧走跟不动且 roll 误差继续变大」,那才是权限账 … 解法是提 hip_roll 的 kp 或降 vy 目标,不是硬训。”
train/C_LADDER_RUN.md § 3d. roll 权限:已部分澄清,不是硬上限 The run policy never left the ground and fell in the second simulator from the frontal plane - its DR (gains and latency only) covered the actuator axis, not the frontal-plane contact and inertia disturbances the doubled stride amplified; "is DR on" is the wrong question
thin-dr-judged-by-channel-coverageJudge a DR recipe by whether its randomized terms cover the channel where the skill can lose stability, not by whether DR is enabled; when a new skill lengthens single support or enlarges motion in one plane, add disturbances in the plane it destabilizes before training.
Symptom
run R1 (6,000 iterations, 78 min): no flight phase ever appeared, and every one of 13 checkpoints failed the eight-gate MuJoCo smoke. In Isaac: zero terminations in 6,000 iterations, 4.2 deg tilt. In MuJoCo at delay 2: 1/6 survived, falls within 1.9-6.2 s at 50.8-58.7 deg, the most saturated joints all roll joints.
Context
The run contract doubled sagittal travel (knee action scale 0.9, knee swing peak 1.14 rad) with a 0.60 s period and 0.40 duty - long single support - while roll/yaw scales were deliberately left at 0.5. DR copied the s1e recipe: kp/kd (0.9, 1.1) and latency on; mass, COM, joint friction and push all off; ground friction pinned at (1.0, 1.0). Flight was read two independent ways: Isaac's per-foot contact reward stayed 0.845-0.857, never above 0.87 - the arithmetic ceiling of a gait with zero flight - and 30 of 36 MuJoCo seeds had flight fraction exactly 0 (the nonzero six were all tumbling falls). Foot lift itself worked (46-59 mm against a 50 mm design point): the walk-era "not enough travel" failure did not recur.
Change
Verdict FAIL, with the pre-registered first knob (exploration noise 1.0 -> 1.2) explicitly rejected as aimed at a different axis. The lesson was generalized and applied at the next line's design review: the one-leg spec made push, body mass, base COM and friction DR mandatory for its permanent single support and banned the thin recipe.
Outcome
The run line did not continue past R1 in the sources. The one-leg V0 with the wider DR passed its friction-variant gate (mu 0.4 and 1.2) inside a 40/40 acceptance.
Mechanism
Randomizing gains and latency covers the actuator's axis; a skill whose failure lives in frontal-plane contact and inertia needs randomization on that channel (push, mass, COM, friction), or the trainer's exact plant becomes the only one the policy can stand on - the omni_s1 transfer trap a second time, this time with DR switched on.
Applies when
- a policy is flawless in the trainer and falls immediately in a second simulator
- reusing a DR recipe from a skill with a different support pattern
- failures concentrate on one axis (roll, yaw) the DR does not touch
“**机理**: 矢状面行程翻倍 (膝摆动峰 1.14 rad) + T 0.60 + duty 0.40 的长单支撑, 把额状面扰动放大了一个量级; 而 roll/yaw 通道按 §3 **刻意没有放大** (仍 0.5), DR 又是 s1e 复刻的薄配方 (mass/COM/关节摩擦/push **四关全关**, 地面摩擦钉死 (1.0, 1.0))。 … 说明**薄 DR 的判据不能只看"有没有开 DR"**, 要看**开的那几项 是否覆盖失稳所在的通道** —— kp/kd 与延迟是执行器轴向的, 对额状面接触/惯性 扰动零覆盖。 … 0.87 正是「零腾空的走路步态」的天花板算术”
git:Lucen V2@origin/run-line:train/README.md § run R1 FAIL (2026-08-09, run 21-30-30_run_r1): 腾空零, 但病根在额状面不在探索