Training Coach
Doctrine
A report may cite any of these as doctrine-N.
doctrine-1Contract freeze and fingerprint disciplineThe policy I/O contract (observation layout, scales, history semantics, action pipeline) is frozen and fingerprinted; every exported policy is stamped and verified; contract changes ship as new versioned profiles that leave old artifacts bit-identical, and old policies run forever under their era's pinned profile.
Case. The 215-dim omni contract was frozen with a three-machine digest; the one contract-level extension (lateral feed-forward) went in as a new `omni_ff` profile with the old profile provably untouched, and the contract checker caught two real wiring bugs before any training (`contract-freeze-and-checker`). A silently changed gait-clock default would have fed old policies a 25% slower clock - closed by pinned legacy profiles (`legacy-profile-pinning`). A stale derived USD forked plant mass 2.2% until an automated source-vs-derived instrument gated it (`derived-asset-staleness-check`). A gain profile is part of the closed loop a policy was trained in and belongs in its stamp; the recovery line's anchored authority was left out of its manifest and recorded as the gap not to repeat (`gain-profile-belongs-in-the-stamp`), and a second policy behind a deploy-side switch made the handoff state itself a contract (`recovery-two-policies-and-a-state-machine`, `walk-recovery-fsm-handoff`).
Coach application. On any proposal touching obs/action semantics, defaults, or derived assets: demand the version/profile plan, the fingerprint update, and the checker extension in the same change; flag any old artifact that would run under new defaults.
doctrine-2Attribution by resolved training params - never eval-override knobsCapability differences between lineages are explained only by digging each lineage's *resolved* training configuration and eliminating columns; evaluation-side override knobs (kd-scale, power-scale, cycle-time) act on the plant for *every* policy and may serve as deployment mitigations but never as explanations.
Case. Low-friction robustness across 8 lineages x 3840 cells was traced to kd DR *bandwidth* - every lineage had ground friction pinned to (1.0,1.0), so "trained friction" could not be the axis; the parameter axis and the plant axis were explicitly separated after the first attribution conflated them (`kd-bandwidth-mu-law-attribution`). "Weak turning" on hardware was a power-scale plant effect, not a training gap (`deploy-knob-attribution-before-retraining`); slowing the deploy clock was out-of-distribution, not a feature (`cycle-time-override-is-ood`). The ground truth for what a run trained under is the logged per-run config, not the source tree (`resolved-config-is-source-of-truth`).
Coach application. Whenever asked "why is lineage A better", require the resolved-param table first; kill zero-variance columns; refuse explanations phrased in eval-knob terms; when a knob helps, label it deployment mitigation.
doctrine-3PASS gates become constraints; FAIL gates become objectivesOnce a skill passes its gate, that gate converts into a standing regression constraint (budget <= 2/20 against the parent baseline) for all later training; gates currently failing are the only legitimate objectives of the next rung.
Case. The C ladder ran one frozen 13-cell x 20-seed matrix at every rung with promotion = "new skill PASS and old skills within regression budget"; C1 was stopped and re-rooted precisely because it trained away the root's backward PASS (`fixed-acceptance-matrix-per-rung`, `preregistered-stop-criteria-per-rung`). The C4 product shipped only at 260/260 cells with zero regression.
Coach application. Keep the ledger: every PASS adds a constraint row; propose rungs only against FAIL rows; treat any constraint violation as stop-and-attribute, never "the next rung might win it back".
doctrine-4One variable per ladder rung - counted against what the checkpoint sawA rung changes one variable, where "one" is counted against the checkpoint's actual training state, not against the current config's diff; batching is allowed only when each change owns a disjoint symptom space with a pre-registered ablation order.
Case. Two rungs failed identically because resuming s1e-500 under the evolved config silently added four plant variables the checkpoint had never seen ("单变量纪律不只看「我改了什么」,还要看「checkpoint 见过什么」" - `resume-state-dr-audit`). v8 legally batched four orthogonal fixes with a written ablation order (`orthogonal-batch-with-ablation-order`); v9 spent one run completing a 2x2 factorial so either outcome convicted a factor (`fill-the-missing-factorial-cell`); v10b's three-way ablation wrongfully convicted the clock and had to be retried fairly.
Coach application. Before any resume: diff cfg against the checkpoint's logged training state. Before any batch: require the symptom-ownership map and ablation order in writing.
doctrine-5Pre-register risks, readings, and stop criteria before the ladderBefore a ladder or risky rung, write down the known risks, the interpretation of every plausible outcome, and hit-any-one stop criteria - frozen before training, tightened when priors say results should come fast.
Case. The C ladder opened with three numbered risks including the exact falsification condition for its own root choice; A/B arms carried "预注册读法(事后不改)" tables; a level expected to fail was run anyway for its pre-registered diagnostic value (`preregister-risks-and-fork-readings`). Stop criteria caught C4-redo rungs at +200 instead of full caps (`preregistered-stop-criteria-per-rung`); hardware sessions pre-registered per-config expected signatures and the disagreement rule "不改结论改账" (`preregistered-real-expectations`, `feasibility-accounts-lock-design-point`).
Coach application. Refuse to open a rung without the written risk/reading/ stop block; after results, read conclusions off the pre-registered table and flag any post-hoc reinterpretation.
doctrine-6Plant parameters are measured, never inventedEvery plant number carries measurement provenance: armature = N^2 x rotor inertia from no-load tests, friction split by rig and by API column, torque limits shaped by per-joint gait peaks, latency traced through the real pipeline, masses weighed - and DR bands are additive around the measured nominal, sized to the measured dispersion.
Case. Guessed friction was 2.5x low and guessed damping 5x high (`friction-measured-not-guessed`); armature had been 0 with a 9:1 gearbox (81x reflected inertia, `armature-n2-rotor-inertia`); a uniform torque derating was "the wrong shape" vs measured peaks (`torque-limit-shape-by-measured-peaks`); the delay implementation itself was a wrong plant for a whole lineage (`latency-lerp-reverse-extrapolation`); the run design point was locked by three accounts including the tau_limit/kd speed ceiling (`feasibility-accounts-lock-design-point`); identified friction had to land in the right simulator API columns to act at all (`sim-api-friction-columns`). The recovery and one-leg lines opened with the same kind of accounts before any reward existed - a connected static path and the torque along it for an armless get-up, and the gains single support needs to be holdable at all (`get-up-feasibility-accounts-before-training`, `single-support-gain-authority-probe`).
Coach application. For any plant value in a config review, ask "measured how?"; reject absolute ranges with no nominal; check API column mapping and derived-asset regeneration whenever measured values land.
doctrine-7Sim2sim gate before sim2real - under deployment conditionsEvery checkpoint passes a second, independently built simulator before hardware, and both the gate and the smoke loop run under the measured deployment conditions (real pipeline delay, honest contact parameters, the deployment gain/power profile).
Case. The standing order "先sim2sim 再sim2real" (`sim2sim-gate-before-sim2real`); acceptance flipped to match hardware only under measured condim/torsional friction (`eval-plant-honesty-contact-params`); gates moved permanently to `--delay 2` after the kicking incident (`pipeline-latency-is-plant-not-dr`); and the harness itself must be audited - a frame-convention bug in the cross-sim evaluator invalidated a whole line of verdicts (`body-frame-velocity-api-audit`). The recovery line's second simulator caught a torque penalty paid for by bracing the legs together (`torque-penalty-bought-by-leg-bracing`), and a 1.8x torque disagreement between the two plants stayed binding because its one surviving explanation was never tested (`torque-disagreement-between-simulators-unresolved`).
Coach application. Block any hardware request lacking a second-sim PASS at deployment conditions; when sim2sim and training-side metrics disagree, treat the evaluator as a suspect too.
doctrine-8Observation honesty - the actor's inputs are a hardware contractThe actor observes only signals the real robot produces with realistic noise; privileged truths go to the critic; history windows are estimators and must train under plant variation; rewards on quantities the actor cannot observe buy only average suppression, never closed-loop correction.
Case. Ground-truth velocity/forces went critic-only (`observation-honesty-critic-only`); frame_hist under zero DR memorized the trainer's plant fingerprint - 0/20 transfer (`history-obs-needs-plant-variation`); world-frame yaw rewards could not teach pull-back because heading is unobservable to the actor - correction was routed to the deploy outer loop instead of breaking the contract (`reward-observability-limit`, `deploy-heading-loop-and-align-training`).
Coach application. Audit every actor-obs element for hardware existence; require minimal plant jitter whenever history/recurrence exists; for each reward, ask "can the actor see this error?" and route correction tasks to outer loops.
doctrine-9Reward economics are audited in realized currencyReward design decisions are made on realized per-step magnitudes under the actual policy and command distribution: price the do-nothing optimum before adding a mode, compare achieved values to the computed ignore-floor, calibrate thresholds between measured healthy and sick distributions, and ship every new penalty with a withdrawal clause.
Case. feet_air_time at weight 2.0 realized 0.038 vs tracking 1.2 - drag was rational (`realized-contribution-audit`); ignoring a vy command cost 28-180x less than ignoring vx until a gated tracking term was added (`reward-cost-of-ignoring-audit`, `gate-new-reward-terms-by-command`); achieved-vs-floor separated "never learned" from "priced out" (`ignore-floor-diagnosis`); the foot-distance wall was placed between measured healthy (0.6% tax) and sick (55%) policies (`calibrate-threshold-between-healthy-and-sick`); the landing penalty carried a pre-registered stand-down condition and actually stood down (`calibration-threshold-with-withdrawal-clause`); two clearance terms were inert until zero-points and gate occupancy were checked (`inert-reward-term-audit`). A get-up policy sat because three gated terms paid the seated pose 84% of the return and the one term that could tell sitting from standing was an exp kernel reading 4.6e-5 at the real error (`seated-basin-dead-exp-kernel`); a torque-tail term was weighted by its measured steady value beside a peer term after the estimate proved 12x off (`tail-torque-needs-hinge-on-computed-demand`).
Coach application. Never discuss weights in the abstract: demand the realized-contribution table, the ignore-floor number, and the healthy-pay calibration before any reward edit is approved.
doctrine-10The zero-cost option must be the desired behaviorFor every penalty, name what the zero-cost option is; penalize failure events (slip, saturation excess, contact in flight windows), never the motion or joints that healthy behavior uses; make degenerate strategies fatal via termination where penalties cannot price them out.
Case. Joint-usage penalties for drift taxed a 1.4%-of-momentum channel 2.7/step and collapsed training; the slip penalty costs a non-slipping gait exactly zero (`penalize-the-slip-not-the-joint`). A frozen-at-clamp joint pays zero action-rate forever - only a pre-clip saturation penalty flips the cheat economics (`saturation-cheating-zero-rate-cost`). Ungated phase shaping made standing 42x more expensive than stepping and cooked the hip motors (`moving-gate-42x-stand-tax`); crouch-shuffling lived until a height termination deleted it (`termination-closes-degenerate-basin`). A gated penalty is an exit: the policy parked just outside an uprightness gate, then just under a height gate, to stop paying a stance tax, and only a positive band plus an always-on guard closed both (`penalty-gate-is-an-escape-hatch`); a soft-limit penalty that charged the standing pose itself bought a 4.1 deg lean (`soft-limit-penalty-charges-nominal-pose`); an unpriced foot attitude was spent on edge-standing (`unpriced-foot-attitude-is-a-free-variable`); and the one-leg line listed its cheapest cheats before training and still met one through a zero-gradient band (`enumerate-cheapest-cheats-before-training`, `binary-band-reward-fake-touchdown`).
Coach application. Run the "零代价的选项是什么" audit on every proposed term; convert motion taxes into event-conditional penalties; check the termination set against each known degenerate strategy.
doctrine-11Measurement discipline: independent referees, signs, distributionsA disputed measurement is adjudicated only by an independent algorithm from raw state; directional ability requires sign-antisymmetry under command reversal; bimodal metrics are reported as mode shares (never medians, never 3 seeds); ratios are not comparable when totals change; reward values compare only within one command distribution; single chaotic events never cross machines.
Case. The triple reversal - a good metric was "refuted" by a sibling metric that shared the disease (`independent-referee-for-metric-disputes`, `body-frame-velocity-api-audit`); same-signed +/- responses were bias, not turning (`same-sign-response-is-yaw-bias`); the swing median sat in a bimodal gap (`median-hides-bimodal-distribution`); "v6 is jitterier" died on absolute energies (`ratio-metrics-need-absolute-check`); yaw gain measured 15x wrong in an oscillating frame (`heading-integral-not-body-rate`); a 44% improvement evaporated under same-distribution comparison (`same-distribution-reward-comparison`); drift direction was a limit cycle (`multiseed-sign-test-for-drift`); a cross-machine push cliff was chaos (`single-impulse-recovery-is-chaotic`).
Coach application. Before accepting any surprising number: ask for the independent recomputation, the sign pair, the distribution shape, and the comparison conditions. Retract in writing when a metric falls.
doctrine-12The deployment pipeline is plantIrreducible pipeline properties - action latency, rate limits, power/torque scaling, teleop command mappings - are part of the nominal plant, modeled from day one and reproduced in every gate; deploy-side scalings are crutches that flag unmodeled plant, and they cannot be algebraically folded into training constants.
Case. Right-leg kicking was over-trained-delay x loop gain; power 0.8 was a gain-reduction crutch that retired when the delay was modeled (`pipeline-latency-is-plant-not-dr`); power derating damages non-forward axes first (`power-scale-hurts-nonforward-axes`); training at 0.4 scale as the "twin" of deploying 0.5 x 0.8 collapsed 0/20 (`deploy-scaling-not-training-equivalent`); one shared teleop speed sent an out-of-band lateral command and the robot clipped its own foot (`teleop-command-band-per-axis`); the latency DR range had not even covered the measured pipeline (`latency-dr-covers-measured-pipeline`). A rate limiter added at deployment only clipped a policy that kept commanding (`deploy-rate-limiter-windup`); moved into training and anchored on the last command it became an integrator in the balance loop (`slew-anchor-is-an-integrator`); anchored on the measured angle it bounded torque and kept the bandwidth (`beta-anchored-action-target`). The walking lines' safe setting, power-scale 0.8, cut the ends of the recovery policy's full-range travel and left its spikes alone; a gain inside the trained band did the job (`power-derating-cuts-full-range-contract`).
Coach application. Demand the measured pipeline latency/limits in the plant model and in gate conditions; treat every deploy-side derating as a question ("what is this compensating?"); block per-axis command sources that exceed training bands.
doctrine-13DR budget is finite; its distribution is the measured supportRobustness is a conserved budget: disturbance training on an already-hardened lineage borrows from existing margins; DR ranges span the measured deployment support - no fictitious tails (they buy degenerate gaits), no single constants (they allow thin-margin specialization); harden the plant only after the task distribution is final.
Case. The same push dose helped a narrow lineage and damaged a balanced one - budget conservation (`push-dr-conditional-budget-conservation`); wide latency tails bought drag-glide, constant values shipped 60% thinner tilt margins - the answer is a narrow band on the measured support (`dr-tail-plant-continuation`, `constant-value-dr-overfits-margin`); task-first ordering because hardening a soon-to-change task wastes budget (`task-shaping-before-plant-hardening`); COM randomization used deliberately as a behavior-shaping tool, and rolled back on symptom per its own contract (`com-randomization-forces-leg-spread`, `com-dr-rollback-on-symptom`). DR that is switched on can still be thin: the run policy fell in the frontal plane its gain-and-latency randomization never touched (`thin-dr-judged-by-channel-coverage`), and a friction priority settled under one action contract had to be re-measured under the next (`friction-priority-re-measured-after-plant-change`).
Coach application. Before any DR rung: check the untrained policy against the spec, the lineage's current DR load, and the measured real-world range; after it: audit retained margins, not just the new tolerance.
doctrine-14Gates measure what hardware feels: posture, margins, stripped assistsAcceptance batteries carry posture-class rows (tilt max median, per-joint L/R asymmetry, temperature) beside task rows, graded margin columns beside binary gates, chirality scored per side, at least one condition that removes the environment's free stabilization, and validated predictive scalars promoted into the gate.
Case. Three same-shaped judging errors - survival, displacement, wz-difference - all missed what the operator felt; posture metrics had the predictive power (`task-metrics-vs-posture-metrics`, `stand-gate-posture-not-survival`); binary survival saturated and hid a 60% margin gap (`constant-value-dr-overfits-margin`); v5 passed everything on the ground and failed suspended (`suspension-probe-removes-free-stabilizer`); the hip_roll (l+r) scalar predicted real drift direction and ordering and entered the battery (`hip-roll-sum-predicts-lateral-drift`); averages hide chirality (`chirality-scored-separately`); gait-quality gates are judged at speeds that demand a gait (`low-speed-commands-reward-dragging`). The recovery line added the rest of the kit: where failed episodes end, not only where they started (`end-state-confusion-matrix`); a frozen acceptance distribution with a pinned seed (`frozen-acceptance-distribution-and-pinned-seed`); video of the metric rollout itself (`video-as-acceptance-record`); and the admission that a 10 s episode cannot see a stance that fails after a minute (`episode-length-bounds-what-a-gate-sees`). The one-leg line removed a foot-spacing wall that no gate measured, and the feet met on hardware (`removed-wall-returns-on-hardware`).
Coach application. Review every battery for posture rows, margin columns, per-side scoring, and an assist-stripped condition; when operator feel and gates disagree, suspect the metric class first.
doctrine-15Fork and root selection: recoverability, maturity, frozen rewardsChoose fork roots by which candidate's deficits the coming training can pay back (precision is recoverable; lost plasticity, symmetry, and margins are not); prefer mature checkpoints as roots even when younger ones score better as products; never fine-tune through a reward change - continuation is legal only with the reward frozen and plant/DR widening one rung at a time.
Case. s1e-500 beat higher-precision candidates because its exclusive strengths were unrecoverable (`fork-root-recoverable-shortfall`); the b300 arm proved maturity is capital against adaptation shock (`root-maturity-vs-product-quality`); the B-arm scatter/half-recover/collapse signature falsified reward-change fine-tuning and drew the legal boundary for S2 continuation (`fine-tune-reward-change-falsified`).
Coach application. For root debates, build the exclusive-strengths table and ask "which side can be trained back?"; require dual-arm evidence for maturity claims; classify any proposed continuation as reward-frozen or not before approving.
doctrine-16Curricula: verified engagement, lineage counters, disease-phase gatingAutomatic curricula must prove they engage (a saturated ratchet is constant DR wearing a curriculum's name); every ramp counts lineage-cumulative progress, not per-process steps; penalties aimed at late-stage pathologies ramp in after exploration noise decays; difficulty rises on measured per-stratum success, never on schedule.
Case. The s1f ratchet capped at iter 248 and never engaged (`auto-curriculum-engagement-check`); the saturation ramp re-fired at +600 after every resume and no shipped product ever saw the penalty (`curriculum-counter-lineage-steps`); the same penalty worked once gated to the disease phase and became an untouchable mechanism (`gate-penalties-to-the-disease-phase`); record-high aggregate reward hid a fully-failing delay stratum (`aggregate-metrics-mask-subgroup-failure`); bucket share is not a gradient lever (`bucket-share-is-not-a-gradient-lever`). An assist curriculum keyed to a pooled success share was withdrawn on the strength of the categories that already worked (`curriculum-criterion-conditioned-on-lagging-category`); a pace set by per-step income moved only when that income was time-gated (`per-step-income-drives-speed-time-gate`), and the same gate had to be retired in a lineage without the disease (`time-gate-vs-wide-stance-retire-the-fix`).
Coach application. Ask every curriculum three questions: does it engage (show the internal state)? what does it count (process or lineage)? when is it present (against the pathology's phase)? Check where shipped checkpoints sit relative to every ramp.
doctrine-17Probe before training: feasibility first, hypotheses in tablesAfter two failed training attempts at a skill, stop training: demonstrate the behavior open-loop, enumerate hypotheses in a written table audited against actual configs cheapest-first, race one probe per side of the sim2real boundary for hardware-only pathologies, and use suspended tests to acquit or convict actuators before blaming authority.
Case. "在黑暗里试钥匙" - four sidewalk rungs failed until an open-loop probe separated exploration/waveform/authority in one experiment (`open-loop-probe-before-reward-tuning`); the foot-drag mystery fell to a seven-hypothesis config audit (`hypothesis-table-code-audit`); the period-doubling was resolved by racing a reward-side and a plant-side evidence line - and both paid off, one per sub-case (`period-doubling-evidence-race`); the suspended test acquitted the roll actuator in one measurement (`suspended-test-isolates-actuator-authority`). A read-only configuration probe told a wall from a slope in the recovery line's seated basin (`configuration-probe-wall-not-slope`), and the fix it pointed to - where the feet are - took prone from 0/159 to 158/159 (`prone-dead-end-is-foot-placement`); a knob that did not move its variable was recorded as no test of the idea (`dof-vel-penalty-is-not-a-pacing-knob`).
Coach application. When a skill resists training, prescribe the probe before any further reward edits; require verified target trajectories before imitation terms; keep a falsified-fixes list so closed roads stay closed (`amplitude-cut-falsified-yaw-fix`).
doctrine-18External advice is recomputed locally; values transfer as ratiosEvery external suggestion is classified adopt / already-have / modify / trap by recomputing its claim on the local reward table and probe data; numeric values transfer only as dimensionless ratios (to tracking weight, leg length, sqrt(gL), control rate); citations are verified to exist.
Case. "Start vy very small" would have destroyed sidewalk learning on this reward table - the gradient scales quadratically (`external-advice-audit-against-own-arithmetic`); swing-height targets and weights transferred correctly only through leg-length and tracking-ratio scaling (`transfer-ratios-not-absolutes`); the "6-step delay" was refused for lacking a control rate (`latency-dr-covers-measured-pipeline`); a borrowed reference's structure was FK-verified and its amplitude re-derived from the division of labor (`reference-structure-fk-amplitude-division`); retrieval agents fabricated verbatim arXiv quotes - only source-verifiable material was used; and one dismissed suggestion later proved right for a different mechanism, and was credited (`cycle-average-tracking-for-gait-quantities`). An advisor's staged state machine turned out to exist in none of the three papers it cited, and reading them changed the plan (`advisor-paraphrase-vs-paper`).
Coach application. Intercept every "paper X does Y" with the local recomputation; convert absolutes to ratios before comparison; verify quotes; revisit dismissed advice when new mechanisms appear.
doctrine-19Hardware sessions are scripted experiments, not tuning sessionsReal-robot time executes a pre-registered matrix: risk-ordered (baseline first, fragile last with a spotter), stage-gated (suspended smoke before ground), A/B sessions bracketed by a repeated reference run, operators briefed on measured zero-command and untrained-axis behavior, chirality-aware disturbance protocols, no field tuning - the only legal field changes are scripted, single-variable, and self-reversing.
Case. The S2 acceptance sheet (`risk-ordered-real-deployment`, `battery-bracketed-real-ab`, `know-zero-command-behavior`, `push-test-chirality-protocol`, `no-field-tuning-protocol`); the RAM-only torque experiment with automatic power-cycle rollback (`reversible-single-variable-field-experiments`); and the sim-veto rule - even sim's condemnations get one safeguarded hardware check when they judge the purpose-built configuration (`sim-veto-needs-real-confirmation`). The recovery line's first real run went ahead with its preconditions unmet and was stopped as dangerous (`first-real-get-up-violent-stage-one-policy`); after it: a staged hang, mat and floor protocol (`staged-hang-mat-floor-for-get-up`), a fixed power-cycle pre-flight and two-machine discipline (`power-cycle-preflight`, `two-machine-config-discipline`), a fall guard replaced rather than switched off (`fall-guard-becomes-a-state`), and logs that are part of the run (`hardware-log-is-the-attribution-input`).
Coach application. Turn every hardware request into a runbook with order, gates, brackets, briefing, and anomaly plays; refuse improvised parameter changes on the floor.
doctrine-20Close questions in writing; restart when the debt is structuralAudited questions get frozen verdicts with citable wording and an explicit reopening bar; hardware verdicts are dated by deployment-stack and calibration state and expire when those change; and when successive rungs shuffle symptoms without net progress, freeze the lineage as regression baselines, pay the structural debts, and retrain minimal - carrying laws and instruments, not weights.
Case. The chirality and COM questions were closed with frozen wording and "no reopening without new hard evidence" (`frozen-verdicts-semantic-boundaries`); v5/v6's condemnations expired with the deploy stack (`stale-verdicts-under-old-stack`); a 2-degree calibration fix moved the whole runnable envelope (`zero-offset-calibration-shifts-envelope`); plant upgrades are era boundaries with paired re-baselining (`plant-swap-invariants-vs-shifts`); and the 2026-08-05 reset froze v5-v11, fixed the latency FIFO / manifest / sampling / reward-table debts, and restarted - producing the lineage that reached hardware SOTA (`freeze-lineage-fix-structure-restart`, `minimal-reward-table-with-provenance`). The recovery line's real-robot verdicts ended up in three places that disagree, one of them an undated note in a command file (`write-hardware-verdicts-back`).
Coach application. Maintain the closed-questions ledger and quote it when symptoms recur; stamp verdicts with stack/calibration versions; when a team is three rungs into symptom-shuffling, raise the restart question explicitly with the freeze-fix-restart pattern.
doctrine-21Name the quantity in the space it lives inA goal, reward term or acceptance criterion about the feet, the base or the contact state is computed from the quantity itself - world poses, forces, per-category outcomes - never through a joint-angle, single-signal or pooled stand-in that assumes everything else sits at nominal; and every detector is validated on a behaviour known not to contain the event before it becomes a gate.
Case. The recovery line was caught three times: |ankle roll| as "flat feet" sold stance width and the real robot slid into the splits, a hip-roll criterion was confounded by 50 deg of yaw, and the joint table said 0.271 m where the feet were 0.159 m apart; task-space terms produced the first flat, wide stance (`joint-space-proxy-for-task-space-quantity`). Flight detection lied in both directions across two lines - foot height flagged 40% false flight on a walking gait, contact force alone flagged slip chatter as hops (`contact-detector-single-signal-lies`). A pooled height average described a robot that did not exist - six in ten standing, four in ten sitting (`zero-partial-credit-is-not-an-iteration-problem`) - and the walking line had learned the same lesson on yaw rate (`heading-integral-not-body-rate`).
Coach application. For every reward term and gate row, ask what physical quantity it stands for and whether it is measured directly; flag joint-space or single-signal stand-ins for task-space goals, ask for a detector validated on a negative control, and split pooled metrics by category before reading them.
doctrine-22Continuation needs a live gradient; a release is chosen by a scanContinue a converged policy only on a change that creates a live gradient, on a short budget, with every checkpoint scanned on the transfer axis; choose a release by running the full battery over a band of checkpoints and stop on signals, never by taking the last one; and when edits to the terminal phase cannot move a behaviour, roll back and retrain with the constraint present from the start, keeping the order in which the lineage acquired its mechanisms as explicit curriculum phases.
Case. A continuation with no new gradient drifted MuJoCo transfer from 100/98% to 80/28% while every Isaac gate stayed perfect, and a live-gradient continuation at the same depth kept it (`converged-continuation-is-poison`). One-leg checkpoints 100 iterations apart failed 1 and 38 of 40 cells, and late ones degraded (`checkpoint-choice-is-a-full-gate-scan`). Four in-lineage stance fixes failed because the stance was the end of the get-up path, and from scratch it grew right (`stance-decided-by-get-up-path`); fixes stacked on degraded states were rolled back by the user (`stop-stacking-roll-back-and-audit`); and the lineage's final recipe, trained from scratch in one run, sat at 0% because the order of its curriculum was part of the product (`curriculum-history-is-part-of-the-product`). The omni line's short adaptation budgets and mature roots are the same law seen from the other side (`continuation-budget-not-from-zero`, `root-maturity-vs-product-quality`).
Coach application. Before approving a continuation, ask for the new gradient, the budget and the transfer axis in the scan; before approving a release, ask for the scan; after three rungs without progress on the target, propose rolling back to the last good checkpoint and a from-scratch phase plan instead of a fourth patch.
Experience cards
112 cards matching “same-distribution-reward-comparison”.
With no term on foot attitude the robot stood on the edges of its feet (ankle roll -26 deg) from R0.5 to V2.5b; pricing it fixed that and turned stance width into the next free variable - the user saw both on video before any metric flagged them
unpriced-foot-attitude-is-a-free-variableList every posture quantity the hardware cares about (foot attitude, stance width, yaw, knee flexion) and make sure each is priced by a term with real gradient at the observed error; pricing one exposes the next, so re-inspect the feet-level video after every change.
Symptom
Watching the v2_5 video the user said the ankle roll after standing looked very strange - the feet were not flat. The feet view showed the right foot standing on its outer edge; median ankle roll at t = 8 s was -/+26 deg (limit +/-35), mirrored. This was the physical form of the ankle_roll saturation criterion that had failed since R0.5.
Context
No term priced foot attitude: feet_contact_upright counts an edge contact as contact, and stand_pose's wide exp kernel (sigma^2 = 9) gives almost no gradient at 0.45 rad. HoST carries an "ankle parallel" term (+20); this table never had one. Edge standing was made a blocking precondition for hardware (continuous ankle load, unstable contact, wear).
Change
V2.6 (single variable): flat_feet = (|q_l_ankle_roll| + |q_r_ankle_roll|) x upright gate x height gate, a linear hinge with a 5 deg margin, weight -2, continued from V2.5b.
Outcome
Ankle roll -/+26 -> 5.3/5.2 deg, ankle_roll saturation 6.6% (< 10%), feet flat on the feet-view video; success 99.6%, re-falls 0-1%. Then the user watched v2_6: hip yaw constantly tense and the legs very close together. The numbers: hip roll -/+4.9/4.8 deg against a nominal 25 - feet flat and hips open 25 deg cannot coexist without ankle compensation, the new term taxed that compensation, and nothing priced stance width. "Foot attitude as a free variable" was fixed and "stance width became the new free variable" - which the real robot then exposed as splits.
Mechanism
An optimizer spends every posture degree of freedom no term prices; closing one reallocates the slack to the next unpriced one.
Applies when
- a standing or landing posture looks wrong on video while gates pass
- a saturation criterion keeps failing on one joint
- a new posture term was just added
“用户看 v2_5 视频:"起身之后 ankle_roll 非常奇怪,脚根本不是平着站立"。 … 机理:奖励表**无任何脚掌姿态项** —— feet_contact_upright 边缘接触也算触地, stand_pose 的 exp 核(σ²=9)对 26°=0.45 rad 梯度≈0。脚掌姿态是自由变量。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §41 预注册 V2.6:flat_feet —— ⑥ 老账的物理形态被用户目视锁定 A curriculum ramp keyed to the process step counter re-fires on every resume - and shipped policies never saw the penalty
curriculum-counter-lineage-stepsKey every curriculum/ramp schedule to lineage-cumulative progress, not per-process counters; and audit where your shipped checkpoints sit relative to every ramp - a penalty that no product ever experienced is not part of your training.
Symptom
vx+0.30 died at a fixed relative time in every resumed run: resume at 500 -> slide at 1100, zero at 1300; resume at 700 -> slide at 1300, zero at 1500 - absolute depths offset by exactly the resume offset, relative timetable identical.
Context
ramp_reward_weight (the saturation penalty ramp) read env.common_step_counter, which restarts at 0 for every run including --resume. So start_step=600 meant "600 iters after THIS resume", not "lineage iteration 600". The A/B arm pair was the clean proof: their env.yaml differed only in log_dir, only resume point distinguished them, and the omni CurriculumManager had exactly one active term - nothing else could produce that timetable. Second consequence: every shipped checkpoint (s1e-500 at +500, C2-700 at +200, A800 at +100) was selected before its run's +600, so the saturation penalty weight was 0.000 for every product ever shipped - explaining saturation 33% and raw |action| 1.9 against clip 1.0 (hip_roll in bang-bang), i.e. half the heat budget.
Change
Two independent recommendations recorded: (1) make the ramp count lineage steps (add the checkpoint's iteration offset on resume) or pin terminal weights in downstream rungs instead of ramping; (2) give the saturation penalty its own rung - never mixed into a skill-learning rung (that would be two variables again).
Outcome
Explained the recurring +600 death of the highest-amplitude command and the persistent actuator saturation of all shipped products with one root cause; honest caveat booked (at +800 the weight is only -0.086, small, but vx+0.30 is the command demanding the largest action amplitude, so it is squeezed first).
Mechanism
Resumable training splits "the lineage" from "the process"; any schedule keyed to process-local counters silently re-applies its transient to every descendant run, and any product-selection habit that picks checkpoints early systematically samples the pre-ramp regime - the curriculum exists in the config but never in any shipped policy.
Applies when
- resumed/forked training with any scheduled reward or DR ramp
- a metric dies at a fixed offset after each resume
- shipped policies show behavior a late-schedule penalty should prevent
“ramp_reward_weight 读的是 env.common_step_counter,它每个 run 从 0 开始,--resume 也不例外。… 原始 run / 臂B | 500 | 1100 = +600 | 1300 = +800;臂A | 700 | 1300 = +600 | 1500 = +800 … 所有出品其实从没见过饱和罚。… 这解释了 sat_max_pct 33%、raw |a| 最大 1.9(clip 是 1.0)—— hip_roll 一直在 bang-bang,而罚它的那一项权重恒 0。热账的一半在这里。”
train/C_LADDER_RUN.md § 3g. 系统性问题:saturation_ramp 每次 resume 归零 Close a question with an audit, then freeze the wording - later symptoms may not reopen it without new hard evidence
frozen-verdicts-semantic-boundariesWhen an audit closes a hardware-vs-policy question, record the closing evidence, freeze a citable wording for future recurrences, and set the reopening bar explicitly; separate robustness perturbations from plant-truth questions so a DR rung's failure can never silently reopen a closed measurement.
Symptom
Recurring directional bias on the robot kept re-suggesting "maybe the hardware/COM/mechanics are asymmetric", threatening to re-litigate questions that audits had already closed - burning attention each time a descendant policy leaned or drifted.
Context
Two boundary decisions were written as permanent: (1) semantic separation - "S2④ COM ±20mm = 纯鲁棒性扰动,不再承担「解释真机后仰」任务" - if the COM-DR rung degrades, the ONLY allowed conclusion is "policy insufficiently robust to COM uncertainty"; reopening "is the CAD COM wrong" is forbidden because the mass audit was completed and closed (@63f9212). (2) a frozen wording for chirality, to be quoted verbatim whenever left/right bias appears in later rungs: observed directional bias = policy-level spontaneous symmetry breaking; plant asymmetry = no supporting evidence after the mass + model symmetry audit; mitigation candidate pi_sym queued, not blocking. The evidential basis was quantitative: the root policy was perfectly symmetric under +/-6 N*s pushes (40/40) while descendants broke (17/40, 13/40) - "手性是 S2 训练中获得的, 根没有; 机械侧已双 PASS 关案, 不重开".
Change
Closed questions carry (a) the audit commit that closed them, (b) a frozen citable wording for recurrences, and (c) an explicit evidence bar for reopening ("无新硬证据不得重开").
Outcome
Later chirality observations (C2's 15 pp turn gap, hip_roll drift bias) were handled as policy-lineage properties with policy-side mitigations, without a single hardware re-audit cycle.
Mechanism
Symptom classes recur under different guises; without a frozen verdict each recurrence re-runs the same expensive investigation and risks a different (worse-informed) conclusion. Freezing verdict plus wording converts recurring symptoms into citations, while the evidence bar keeps the closure honest rather than dogmatic - the root/descendant symmetry comparison is what makes "it's the training, not the machine" checkable at any time.
Applies when
- a recurring symptom keeps suggesting an already-audited hardware cause
- writing conclusions for a completed calibration/audit
- a DR rung's degradation invites re-measuring the plant
“若 S2④ 退化,结论只能是「当前 policy 对 COM 不确定性不够鲁棒」,不得重开「CAD COM 是不是错了」… 手性冻结表述 … Plant asymmetry: no supporting evidence after mass + model symmetry audit … 无新硬证据不得重开机械不对称”
train/OMNI_V0_SPEC.md § 4. 语义分界与手性冻结表述(2026-08-07 用户定,永久) A ratio metric flipped the verdict - spectral share rose while absolute high-frequency energy fell 16%
ratio-metrics-need-absolute-checkNever compare share/percentage/centroid metrics across conditions whose totals differ; pair every ratio with its absolute numerator before issuing a verdict, and log retracted judgments so they are not re-derived.
Symptom
walk_v6 was provisionally judged "more jittery" than v5 because the joint-velocity spectral centroid rose 2.91 -> 3.62 Hz and the >4 Hz energy share rose 12.6% -> 17.8%.
Context
Absolute measures said the opposite: first differences of actions fell 1.54 -> 1.31, second differences 2.55 -> 2.19, and absolute high-frequency energy fell 16% (0.490 -> 0.413). The shares and centroid rose only because low-frequency content fell even more - the denominator shrank. The interim judgment was retracted in writing so it would not be reused.
Change
Metric discipline noted: "占比类指标在总量变化时不能直接比较" - share/ratio metrics are not comparable across conditions when the total changes; verdicts about smoothness must cite absolute energies or difference norms.
Outcome
v6 correctly classified as smoother, not jitterier; the retracted judgment logged under "被推翻的一个中间判断(记下来免得复用)".
Mechanism
A ratio confounds numerator and denominator; any intervention that removes low-frequency content raises every high-frequency share without adding a single joule of jitter. Only absolute quantities support cross-condition comparison when totals move.
Applies when
- comparing smoothness/jitter/spectral metrics across versions
- any percentage-based metric moves after an intervention
- writing an eval report that includes normalized quantities
“我一度说"v6 动作更抖" … 错了: 动作一阶差 1.54→1.31、二阶差 2.55→2.19 都在降 … 谱质心升高只是因为低频成分掉得更多, 绝对高频能量实际下降 16%(0.490→0.413)。占比类指标在总量变化时不能直接比较。”
train/WALK_DIAGNOSIS.md § 过程中被推翻的一个中间判断(记下来免得复用) Symmetrizing the config made the gait MORE asymmetric - the asymmetry lived in the policy weights
asymmetry-in-weights-not-configLocalize a persistent asymmetry by intervening at the config layer first: if the symptom survives (or worsens), it is in the weights - fix it with symmetry-constrained training, not with trims or offsets.
Symptom
walk_v1 on hardware: straight-line command curved 149 deg in 15 s (9.9 deg/s) with 3.06 m lateral runout; turn gain +31% one way vs +129% the other (75% difference); knee asymmetry 4.4 deg in sim, 9.6 deg on the robot.
Context
The obvious suspect was the asymmetric default pose in the config. The decisive test: symmetrize standing_pose and run the SAME policy in sim - the asymmetry got LARGER (hip_pitch 6.8 -> 9.3 deg). Root cause therefore not in the config but baked into the policy weights: PPO without a symmetry constraint commonly converges one-sided, because splitting the work 50/50 and loading one side yield the same return, and the gradient falls randomly into one of the equivalent optima.
Change
Fix redirected from config trimming to retraining with mirror data augmentation (walk_v2 spec) - a weights-level fix for a weights-level disease.
Outcome
With augmentation (and the symmetric-default precondition), stand_v1 reached 0.0 deg asymmetry on all six joint pairs (from 4.4-7.7 deg), height fluctuation 7 mm -> 1 mm, mean |action| down 33%.
Mechanism
Reward-equivalent solution families (who carries the load) leave the symmetric solution unpreferred; SGD picks an arbitrary member and entrenches it. Config changes move the coordinate frame around the entrenched asymmetric function - they cannot move the function. The counterfactual test (change config, watch symptom) localizes the layer the disease lives in.
Applies when
- a robot veers or loads one side despite a symmetric-looking config
- deciding between config trims and retraining for an asymmetry
- mirrored-turn gains differ by tens of percent
“根因不在配置里:把 standing_pose 对称化后在 sim 里跑同一策略,不对称反而变大(hip_pitch 6.8°→9.3°)—— 说明不对称烙在策略权重里。这是无对称约束的 PPO 的常见收敛结果(左右各担一半与一边多担的回报相同,梯度会随机落进其中一个)。”
train/RETRAIN_v2.md § 1. 为什么是对称增强(证据) Prove an armless get-up exists before training it - a connected static domain, 25% torque on the cheapest path, an 8 mm hand-over gap, a static roll-over - and write down what each scan cannot represent
get-up-feasibility-accounts-before-trainingBefore training a get-up or any multi-contact skill, compute the quasi-static accounts - connectivity of the static domain, torque along the cheapest path, hand-over gaps, COM shift available for rolling - and state which configurations each scan cannot represent; when a policy gets stuck in one of those, extend the scan before blaming the reward.
Symptom
A torso-and-legs robot has no arms to push off the ground; whether it can get up from the floor at all was unknown when the line opened.
Context
recovery_feasibility.py ran three accounts before any training (the run line's "hard accounts first" discipline): a sagittal quasi-static scan (0.05 rad grid, 44,520 configurations, MuJoCo FK, flat-foot assumption). (1) The static standing domain (COM over the feet, torques in limit) has 29,586 cells, flood-fill connected with no islands, from a 0.097 m deepest squat to the 0.384 m stand. (2) The minimum-torque path peaks at 25% of the limits (knee 2.9/12, ankle 3.7/17 N*m) - a 4x margin. (3) All 508 ground-contact configurations have the contact behind the COM; the smallest gap to pure foot support is 8 mm. A roll-over account: swinging both straight legs to one side shifts the COM 96 mm against a 62 mm torso half-width - 1.6x, so rolling needs no momentum. Three conclusions were written down for later attribution: the legs are 80% of the mass (swinging them moves the COM), prone has no flat-foot hand-over face (merge into a supine/side sit first), and supine needs no sit-up (hip flexion is limited to 75 deg).
Change
The accounts gated opening the line and were cited in every later argument about what the robot can physically do.
Outcome
They held where they applied: in V1.0 every fall category was righted under a hard rate limit, which the spec records as the quasi-static roll-over account verified by training, and the 25% torque path was the basis for pursuing a slow get-up. They also misled once: account (3) is sagittal, and on 08-09 the spec corrected its scope - it cannot represent the splayed W-sit where the policy actually stalled. A follow-up prone hip-ROM scan (471,625 cells) found 3,912 two-foot-contact cells and none with both soles within 25 deg of level (best 40.2 deg): a flat-footed push-up from prone is infeasible on this robot, so the fix became where the feet go after sitting up.
Mechanism
A get-up needs a connected path through statically feasible configurations and enough torque along it; quasi-static accounts bound both cheaply, and momentum can only make the real problem easier. A reduced-dimensional scan, though, only speaks for the configurations it can express.
Conflicts
In R0.1-R0.2 the spec read account (3)'s "prone has no front hand-over" as "prone lacks the roll-over skill"; R0.3's confusion matrix showed prone had righted its torso 159/159, and the spec then restricted account (3) to the sagittal configurations it models.
Applies when
- opening a get-up, recovery or climbing skill on a new robot
- a robot lacks arms or other obvious contact options
- a policy stalls in a configuration a feasibility scan never modelled
“本机 **torso + legs、无手臂可撑地**,开训前先证明存在不依赖手臂的物理解 … 双腿同侧直腿摆最大横移 **96 mm = 1.6×** … **静态摆腿即可翻身,无需动量**”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §1 机械可行性判决(2026-08-09,recovery_feasibility.py 三笔账) Diagnose a behavior failure by enumerating hypotheses and auditing each against the actual config, cheapest first
hypothesis-table-code-auditBefore changing anything, write the full hypothesis list for the symptom and audit each against the resolved config and measured magnitudes, cheapest check first; train only on the survivors.
Symptom
Real robot leaned forward "wanting to walk" but dragged its feet instead of lifting them - a symptom with many plausible causes and no obvious single fix.
Context
Seven hypotheses were listed and each checked against the actual training config files (velocity_env_cfg.py, isaac_values.py), ordered by check cost: missing foot clearance term (CONFIRMED, primary - feet_air_time existed but no swing-height term at all); energy penalties dominating (REJECTED - energy terms total -0.19 vs tracking +1.2, 16%); command range too narrow (CONFIRMED - (0.15,0.35)); nominal pose too crouched / action scale too small (HALF - knee 0.5 rad = 28.6 deg deep, scale fine); mixed PD across motor types (REJECTED - already grouped); missing base-height reward (REJECTED - present at -5.0); height-drop termination (REJECTED - none exists, which itself became finding #4 of the fix list).
Change
The audit produced a ranked fix list (add clearance penalty; widen speed range; reduce nominal crouch) with each rejected hypothesis documented so it would not be re-litigated.
Outcome
Three confirmed causes fixed over v5/v6: swing height went 22-23 mm -> 34 mm, tracking 81% -> 87%; the rejected hypotheses stayed rejected (no wasted rungs on energy weights or PD grouping).
Mechanism
Multi-cause symptoms invite guess-and-train loops; a written hypothesis table forces each candidate to be confirmed or rejected against actual values (not impressions), and cost-ordering the checks means most hypotheses die for the price of reading a config.
Applies when
- a real or sim behavior failure has multiple plausible causes
- the team is about to "try a fix" without an audit
- post-mortems keep re-proposing already-rejected causes
“真机现象:躯干前倾像要走,脚抬不起来(拖着蹭)。按成本从低到高逐条核查 … | 1 | 缺 foot clearance | ✅ 成立,首要 | 有 feet_air_time,无任何摆动足高度项 | | 2 | 能量惩罚压过跟踪 | ❌ 不成立 | 能量类合计 −0.19,跟踪 +1.2,只占 16% |”
train/WALK_DIAGNOSIS.md § walk 拖地问题 — 七条假设的代码核查结果 A hardware run without its log is an anecdote - the first real get-up's policy, gain profile and log were never recorded, two CSVs stayed "to be reported", and runbook commands wrote different policies' logs under one copied filename
hardware-log-is-the-attribution-inputMake the log part of the run: name it from the policy and conditions automatically (never by hand-copied filenames), record the policy digest and gain profile inside it, include what the open questions need (torque, joint positions and targets), and treat a session without a collected log as incomplete.
Symptom
The recovery line's oldest open question - whether Isaac or MuJoCo reads torque demand correctly - was waiting on real-robot logs that never arrived, and the verdicts that did arrive could not be tied to files.
Context
deploy_policy writes a CSV per run (--log); the runbook's own analysis snippet reads its joint-position, target and action columns (q_, tgt_, act_), and the recovery hanging checklist asks for torque and joint logs for the whole run, to be compared with simulation. The first real get-up (08-09): policy, gain profile and log "to be recorded later". The first real A/B (08-11): v2_5b's result and both policies' CSVs "to be reported". In the runbook's walking commands, three runs of two different c4 policies log to real_s1e_pw08_teleop_0808.csv, and s1e and s2e_fric runs log to real_c2_700_pw08_teleop_0808.csv - filenames copied from other commands.
Change
None recorded; the spec kept listing the open-loop comparison as waiting for real logs.
Outcome
No real-robot log appears in the recovery spec through §50, so the simulator disagreement stayed unresolved and hardware verdicts stayed unattached to data.
Mechanism
Attribution needs the run's identity (policy digest, profile, conditions) and its signals in one artifact; a filename copied from another command mislabels the file, and a log not collected at the session is rarely collected later.
Applies when
- planning a hardware session whose result should settle a sim question
- log filenames are typed or pasted by hand
- hardware feedback arrives as prose without files
“python tools/deploy_policy.py --policy train/policies/omni_c4_ff800_pj.onnx … --log train/real_logs/real_s1e_pw08_teleop_0808.csv … q,t,a=d[:,c("q_")],d[:,c("tgt_")],d[:,c("act_")]”
RL系统/FOLLOW THIS copy 2.md § Walk 遥控 / S2 / csv 分析片段 (operator runbook, undated) Adapting a lineage to one plant increment needs hundreds of iterations, not thousands - long runs only buy specialization
continuation-budget-not-from-zeroBudget continuation rungs by increment class (hundreds of iterations for plant pins and smooth shifts, ~1000-1500 only for behavior-demanding changes like push), enforce a hard cap with frequent evaluation, and treat remaining budget as a reason to stop, not to continue.
Symptom
The default "6000 iterations per rung" (a from-zero-scale budget) was about to be applied to continuation rungs whose only change is one plant/DR increment - overspending compute and, worse, giving each rung thousands of iterations to specialize away retained skills.
Context
The 2026-08-07 budget table replaced the default with "最低适应窗口 + 每 100 iter 验收 + hard cap" scaled to the increment's difficulty: fixed-latency levels 300-500 (cap 500-800; the base has already seen in-band values, this only pins the plant); PD full-band 700 (cap 1000; kp+/-20%/kd+/-30% clearly widens the actuator family); COM +/-20 mm 500 (cap 800; a smooth dynamics shift); friction DR 700 (cap 1000; contact and actuator friction change the gait/contact solution together); push 1000 (cap 1500; a non-static plant change requiring recovery behavior - hardest). Rationale: "续训适应一个 plant 增量不需要从零量级的预算,跑长了只是给特化时间". The C ladder reused the scheme (per-rung caps 500-2000 by increment type), and the deep-training hazard got its own name when long runs sold quality ("深适应卖质量" - deep adaptation sells quality).
Change
Per-rung iteration budgets set by increment class with hard caps and 100-iter watch loops; checkpoint selection inside the window by the smoke curve, never "run to cap because budget remains".
Outcome
S2/C rungs completed in 300-1500 iterations each; the recurring late-run degradations (collapse valleys at 1500+, vx+0.30 decay) fell outside most rungs' caps instead of inside their runs.
Mechanism
A continuation rung's learning problem is local robustification around an existing optimum - low sample complexity; iterations past adaptation are spent sharpening onto the current distribution, which is exactly how retained skills and margins erode. Budgets sized to the increment bound both compute and the specialization damage window.
Applies when
- planning iteration budgets for a robustification or command ladder
- a continuation run keeps improving its training metric late
- retained skills decay in the back half of long continuation runs
“「最低适应窗口 + 每 100 iter 验收(watch_ckpt --every 100)+ hard cap」—— 续训适应一个 plant 增量不需要从零量级的预算,跑长了只是给特化时间 … ⑥ push | 1000 | 1500 | 非静态 plant 变化,要学 recovery 行为,最难”
train/OMNI_V0_SPEC.md § 4. 每级 iter 预算(2026-08-07 用户定) A policy's gain profile is part of its contract - the one-leg policy needs per-joint gains the default profile lacks, and the manifest refused an evaluation under the default once; the recovery contract's beta was never stamped, a known gap not to repeat
gain-profile-belongs-in-the-stampStamp everything that defines the closed loop a policy was trained in - gains included - into its manifest, and make every consumer refuse a mismatch; a profile field that is not in the stamp is a silent misconfiguration waiting for an operator to forget a flag.
Symptom
A policy trained with hip_roll kp 80 and ankle_roll kp 60 behaves differently, or falls, under the default kp 20/12 profile - and the gain profile is a command-line flag an operator can forget.
Context
The one-leg line added a gain_profile field to the contract so the stamped manifest carries it; the spec's deployment note says the manifest guard blocks rl_default and that it had already bitten once in simulation (an evaluation run without the one-leg profile). The same spec states the general rule - any new profile field must be synced into the manifest builder - and names the counter-example: the recovery line's beta was never put into the manifest. The recovery line itself had decided that its anchored authority is computed from the base rl gains and written into the contract so it cannot drift with the gain flag, and that the older kp x 0.9 profile chosen in the V0 era does not match the beta contract and must not be used.
Change
Gain profile as a contract field checked at load; per-contract gain choices written into the run sheets.
Outcome
Evaluations and hardware runs of the one-leg policy run under rl_oneleg or are refused; the recovery beta gap stayed recorded as known.
Mechanism
A policy is trained against a closed loop whose gains are part of the plant; running it under other gains is an out-of-distribution plant, exactly like a wrong observation scale.
Applies when
- a skill introduces per-joint or skill-specific gains
- deployment gains are chosen by a command-line flag
- adding any new field to a policy profile
“增益档 `--profile rl_oneleg` 必须给 —— manifest 防线会拦 `rl_default`(sim 已咬合一次) … (recovery 的 β 未进 manifest 是已知缺口,不再复制)”
git:Lucen V2@origin/oneleg-line:train/ONELEG_V0_SPEC.md § §9b AGX 真机手顺 要点 / §3 契约 The latency DR range must cover the measured deployment pipeline - 0-20 ms could not even reach the real 1-2 control steps
latency-dr-covers-measured-pipelineMeasure end-to-end action latency in control steps on your own stack (including cross-process queue boundaries), set the DR range to cover it with margin, and never import a delay count without its control frequency.
Symptom
Action latency was randomized over 0-20 ms (0-1 control step at 50 Hz), but the measured deployment path is 1-2 steps: the deploy process writes the target, an independently running BusWorker picks it up on its NEXT cycle, plus CAN round-trip - the training range could not cover the robot's actual latency at all.
Context
Fix: widen action_latency_s to 0-0.06 (0-3 steps). The external reference's "uniform 6 steps" was explicitly NOT copied - that number depends on his unknown control frequency; locally, a sweep at 0/1/2/3 steps showed walk_v5 survives all with insensitive metrics, so 6 steps "在我们这里没有依据" (has no local basis). The range was set from the measured pipeline with margin, not from a foreign constant.
Change
action_latency_s (0, 0.02) -> (0, 0.06), justified by pipeline analysis (writer/worker cycle boundary + bus time) and bounded by the local latency sweep.
Outcome
The DR band now brackets the true deployment latency; the policy trains against the delay it will actually face instead of a fictional sub-step world.
Mechanism
Latency DR only immunizes against delays inside its support; a range below the physical pipeline guarantees an untrained distribution shift at deployment. The correct range comes from tracing the pipeline's worst case (queueing boundaries + transport), and foreign step-counts are meaningless without the control rate they were measured at.
Applies when
- setting or auditing action-delay randomization
- deployment uses a separate bus/worker process from the policy loop
- importing delay-modeling numbers from other projects
“现行 0~20 ms = 0~1 个 50Hz 控制步, 而实测部署链路是 1~2 步(deploy 写 STATE.target 后, 独立跑的 BusWorker 下一轮才取走下发, 再加 CAN 往返)——现在的区间覆盖不到真机的实际延迟。… 不照抄参考来源的"统一 6 步": 那取决于他的控制频率(未知), 而我们扫过 0/1/2/3 步 … 6 步在我们这里没有依据。”
train/WALK_V7_SPEC.md § ⑤ action_latency_s 0~0.02 → 0~0.06 Privileged signals (true velocity, foot force, foot height) go to the critic only
observation-honesty-critic-onlyTreat the actor observation vector as a hardware contract: every element must exist on the real robot with realistic noise; privileged simulator truths belong in the critic only.
Symptom
Policies trained on ground-truth base linear velocity work in sim and fail on hardware, where only a drifting IMU and encoders exist - the policy has learned to depend on a signal that does not survive deployment.
Context
Many open-source locomotion stacks feed simulator ground-truth linear velocity to the actor. The reference team refused: the real robot has no ground-truth velocity. Asymmetric actor-critic keeps the training benefit of privileged information without deploying the dependency.
Change
Route ground-truth velocity, foot contact forces, and foot heights to the critic only; the actor observes exclusively signals that exist on hardware (IMU-derived quantities, encoders, commands, previous actions).
Outcome
Recorded as adopted doctrine in Lucen's experience log; the trained actor's input contract matches what the real robot can actually produce.
Mechanism
The critic is discarded at deployment, so it may consume any privileged state to reduce value-estimation variance; the actor's observation set is a deployment contract - anything in it that hardware cannot supply (or supplies with different noise/drift) becomes a train/deploy distribution shift the policy was never trained to handle.
Applies when
- designing actor/critic observation spaces
- reviewing a config where the actor sees base_lin_vel or contact forces
- sim policy is strong but real robot drifts, oscillates, or falls without obvious actuator cause
“很多开源代码库把真值线速度喂给策略,Asimov 团队没有,因为真机上没有真值速度,只有会漂的 IMU 和编码器;用完美速度训练出来的策略会依赖它,然后在硬件上失效。真值速度、足底力、足高统统只给 critic”
Experience.md § 观测空间的诚实性 (line 7) The walking lines' safety setting, power-scale 0.8, broke the recovery policy's full-range contract - it cut the ends of the joint travel (4/50 could not get up) and left the torque spikes untouched; a kp x 0.9 gain profile inside the trained kp band did the job
power-derating-cuts-full-range-contractA deployment derating knob means something only relative to the action contract: before reusing a line's "safe setting" on a new skill, check what it does to that skill's reachable range and to the term that makes the spikes, prefer a gain change inside the band the policy was randomized over, verify it in simulation, and re-decide when the contract changes.
Symptom
After the violent first real get-up (2026-08-09), the recovery policy needed a gentler setting for its next hardware test, and the walking and omni lines' standard derating - deploying at power-scale 0.8 - was the obvious candidate.
Context
The V0 recovery contract maps actions to absolute targets over the full joint range: a = +/-1 lands exactly on the URDF limits, and standing puts the knee at the clip. Candidates were compared on R3.1 in MuJoCo (5 categories x 10 seeds) on 2026-08-10 before any hardware time was spent.
Change
A new gain profile, rl_kp090 (kp x 0.9, kd unchanged), recorded in robot.yaml as the recovery hardware-test setting, with power-scale 0.8 explicitly banned for recovery.
Outcome
kp x 0.9: 48/50 got up; median torque demand on hip_pitch/knee fell from 120-125% to 100-104% of the deployment limit; leg-leg contact frames 2,152 -> 1,095; the change sits inside the +/-10% kp randomization the policy trained with. power-scale 0.8: 4/50 could not get up, because under the full-range contract it removes the ends of the travel (the deep squat's tucked legs, the straight standing knee), and the torque spikes (kp x error) did not fall at all. When the line moved to the beta-anchored contract, rl_kp090 was declared a V0-era choice that does not fit (beta is calibrated at kp 30) and deployment returned to rl_default; the deploy switch applies power scaling to the walking side only.
Mechanism
A power scale multiplies the action, which under an absolute full-range mapping shrinks the reachable workspace instead of softening the actuator; the spikes come from the proportional term on large errors, which only a gain change reduces - and a gain change inside the trained randomization band stays in distribution.
Conflicts
The undated operator runbook still carries an R3.1 "B comparison" command at power-scale 0.8 beside the rl_default baseline; the sources do not say whether it was written before the ban or was ever run.
Applies when
- reusing a power, torque or action scale from one skill on another
- a policy whose actions map to absolute targets over the full joint range
- choosing a gentler setting for a first or second hardware trial
“kp×0.9 / kd 不动 —— recovery_r3_1 成功 48/50, τ 需求中位 hip_pitch/knee 120~125% -> 100~104% 部署限, 腿-腿接触 2152 -> 1095 帧; ±10% 在训练 kp DR 带内. ⚠️ power-scale 0.8 对 recovery **禁用**: 全 ROM 契约下 0.8 砍的是行程 端点 (深蹲收腿/站直够不到), 实测 4/50 起不来, 且尖峰 (kp·err) 一点不降 —— 它是 walk/omni 的安全档, 不是 recovery 的.”
git:Lucen-recovery@origin/recovery:robot.yaml § gain_profiles 注释: recovery 真机测试安全档 (2026-08-10) / rl_kp090 Push DR helped one lineage and hurt another at the same dose - robustness budget is conserved and gets borrowed, not created
push-dr-conditional-budget-conservationBefore opening a disturbance-DR rung, measure whether the untrained policy already meets the spec; if training it anyway, expect the benefit to be conditional on the lineage's existing DR load, grade the intensity, and audit retained margins - budget spent elsewhere will be borrowed back.
Symptom
The push rung's outcome flipped with the lineage: direct +/-0.6 m/s push failed outright on first attempt (base walking collapsed - kd1.2 scan 0/3 from iter 3300, sim2sim self-falls with pushes OFF - no PASS point existed); staged +/-0.3 then gave the narrow-kd single-working-point lineage real gains (push survival 1/5 -> 4/5) while the SAME dose made the dual-working-point balanced-band lineage WORSE (20-seed survival 18 -> 12/20 plus across-the-board push regression).
Context
The four-ladder verdict ("四梯定案", s2e/s2f at both intensities) named the pattern: "push DR 收益条件性" - the benefit is conditional on how much robustness budget the lineage has already spent. The law candidate: "DR 总预算守恒, 平衡带鲁棒性从抗扰余量借" - total DR budget is conserved; a lineage already covering a wide plant band pays for push tolerance out of its disturbance margin. Both S2 ladders therefore closed at the friction rung, with the decisive numerator: untrained push tolerance already met the 4-6 N*s requirement, so the rung was not needed at all ("⑥ push 不训(收益条件性,免训 ±0.6 已达 标)"). The same accounting later justified the C-before-S2 ordering ("push/μ 两轮已实证 DR 预算有限且会被重分配") and trimmed the second S2 pass to three rungs.
Change
Push removed from the standing ladder; graded intensity retained as the method IF a lineage ever needs push training; "does the untrained policy already meet the disturbance spec" instituted as the first check before opening any disturbance rung.
Outcome
Two rungs (push, ground mu) deleted from the second S2 pass on measured grounds; the ladder's real yield was re-stated honestly as precision, not robustness (speed gate 0 -> 20/20, zero-command drift 0.98 -> 0.06 m, but push 159 -> 125/160).
Mechanism
A fixed-capacity policy allocates representation and margin across the training distribution; adding a disturbance axis to a lineage that already spans a wide plant family forces reallocation - the new tolerance is bought with existing margins. Lineages with narrow plant coverage have free budget, so the identical DR dose lands as gain. Benefit is a property of (dose x lineage state), never of the dose alone.
Applies when
- proposing push/perturbation training on a hardened lineage
- the same DR rung helped one lineage and hurt another
- accounting where a ladder's robustness gains actually came from
“push DR 收益条件性 —— s2e⑥a (单工作点血统 kd 窄带) ±0.3 得抗推 1/5→4/5; s2f⑥ (双工作点平衡带血统) 同档反而 20-seed 存活 18→12/20 且抗推全面倒退。规律候选: DR 总预算守恒, 平衡带鲁棒性从抗扰余量借。两阶梯均以 ⑤ 摩擦级收官 … 抗推 4~6 N·s 免训已达标。”
train/OMNI_V0_SPEC.md § 4. ⑥ push 四梯定案 (2026-08-07) Teleop fed the sidewalk axis a command beyond its training band - feet clipped; give each axis its own speed setting
teleop-command-band-per-axisGive every command axis its own teleop scale, clamped to that axis's training band, and reproduce any hardware incident in sim with the exact deployed command values before touching training.
Symptom
Robot stepped on its own foot when sidewalking left under teleop - and only when going left.
Context
The teleop tool used one speed setting for all axes: --teleop-speed 0.20 applied to A/D sent cmd_vy = 0.20, above the training band's top (0.08-0.18) where foot-spacing margin is thinnest. Sim reproduction of the incident (product policy, pw0.8, 5 seeds x 20 s, true collision threshold = single foot width 104 mm): at vy 0.20 the minimum foot distance was 111-115 mm - 7-11 mm from self-collision - vs 147 mm at vy 0.10. Left was 4x more dangerous than right (25% vs 6% of time inside the 160 mm soft wall at vy 0.10), matching the left-only symptom; the margin did not degrade over time (pressing more just lengthened exposure).
Change
deploy_policy gained --teleop-side (default 0.10), separating the lateral speed from the forward speed so each axis's teleop command sits inside its own trained band.
Outcome
Command now inside the band with 43 mm margin at default; the incident became a quantified, reproduced, closed account rather than a mystery.
Mechanism
The policy's competence envelope is the training command distribution per axis; teleop mappings that share one scalar across axes silently command out-of-band inputs on the weakest axis. Asymmetric risk (left vs right) came from the policy's own chirality bias, so a symmetric command produced an asymmetric hazard.
Applies when
- wiring a joystick/teleop layer over a learned policy
- a hardware incident occurs on one command direction only
- training bands differ across command axes
“A/D 一直与 W/S 共用速度档,所以按 A 下发的是 vy = 0.20 —— 既超训练带(0.08~0.18)上沿 … 0.20(遥控实际值)| 111~115 mm | 7~11 mm … 且左比右危险 4 倍 … 处置:deploy_policy 新增 --teleop-side(默认 0.10),侧移与前进档分开。”
train/C_LADDER_RUN.md § 3p. 一 向左走踩到自己 → --teleop-speed 0.20 同时喂给了 vy Drop the frozen policy into chosen configurations - a squat 2.7 cm lower than the stuck pose stood 52% of the time, the stuck W-sit 0%, and the interpolation between them showed a wall, not a slope
configuration-probe-wall-not-slopeWhen a policy is stuck, probe the frozen policy from a grid of hand-placed start configurations, including interpolations between the stuck state and a nearby state it escapes from; one read-only experiment separates height, torque, sampling and configuration and tells you whether to prevent entry or train the exit.
Symptom
After R0.3 the policy stood from 62% of starts and never from the W-sit it fell into; height, torque, missing samples and reward were all plausible suspects.
Context
A read-only probe placed the R0.3 policy directly into specified configurations. Squats (hip, knee, ankle) = (-.65,-1.3,-.65) stood 100%, (-1.0,-2.0,-1.0) 89.8%, (-1.2,-2.4,-1.2) at 0.176 m 52.3%; the measured W-sit at 0.203 m 0.0%; the account-(3) hand-over state (146 deg tilt) 34.4%; linear interpolations from the W-sit toward the squat at 25/50/75% stood 0.0/0.0/3.1%. The squat family's quasi-static torque is 16% of the limits, and the W-sit was visited ~9 s per episode in training. FK showed the squat family (-a,-2a,-a) keeps the torso vertical, the feet flat and the COM over the feet all the way from 0.146 m to 0.384 m.
Change
Height, torque and sampling were eliminated in one experiment; the next rungs targeted entering the W-sit (foot placement) instead of escaping it, and seeding the dead point itself was ruled out because it was already visited every episode.
Outcome
Pure configuration: the W-sit (hips externally rotated +/-47 deg, knees folded 110 deg, shins flat, feet beside the body) is a different place from the sagittal squat (feet flat under the COM). The policy's standing skill was bound to a narrow sagittal family, and the wall was confirmed by the interpolation. The foot-placement rungs that followed took prone from 0/159 to 158/159.
Mechanism
A learned skill covers the neighbourhood of the states it succeeded from; a start state outside that neighbourhood fails regardless of height or torque, and an interpolation that stays at zero until close to a working state shows the boundary is sharp.
Applies when
- a policy stalls in a specific posture and several causes are plausible
- deciding between reverse-curriculum seeding and entry-prevention shaping
- a feasibility account says a path exists but the policy does not take it
“**决定性对比:比死点矮 2.7 cm 的蹲姿站立 52.3%,死点 0.0%。** 所以不是高度、 不是力矩(蹲姿族准静态力矩膝 1.96/12、踝 1.24/17,只占 16%)、也不是训练采样 (死点每局被访问 ~9 s)。**是纯位形问题** … 插值实验进一步显示这**不是坡是墙** —— 走到 75% 仍只有 3.1%”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §15 死点位形实验(只读探针,同一个 R0.3 策略放进指定位形) Training at scale 0.4 is NOT the twin of deploying 0.5 at power 0.8 - the algebra matches, the learned policy does not
deploy-scaling-not-training-equivalentNever assume deploy-side scalings can be folded into training-time constants ("burning the crutch into training"): the learned optimum depends on the training-time authority, so treat such conversions as full experiments with pre-registered expectations and a sim2sim gate before any hardware.
Symptom
s1g (S1.6) trained from zero at action_scale 0.4 - meant as the "training twin" of the hardware-proven s1c-at-power-0.8 (0.8 x 0.5 = 0.4) - was all green in Isaac (zero falls, reward 117) yet scored 0/3 across all eight checkpoints and 0/20 at 20 seeds in the MuJoCo gate, falling forward at median 1.57 s with a 2.9x speed overshoot.
Context
The pre-registered expectation (survival gate should pass, since the conviction matrix showed s1c@0.8+delay2 all-survive) was cleanly falsified, and the harness was acquitted by controls: --delay 0 fell identically (not a delay fragility), check_contract all green, and s1c through the same harness survived 2/3. The verdict: "「s1c@0.8 = 0.4 训练孪生」的代数等价不成立" - a policy deployed with a derated output still LIVES in the 0.5 internal model it trained under (its value function, its expectations of its own authority), while a policy that starts training with reduced authority learns a different, clip-hugging gait with zero margin for plant differences ("部署端打折的策略活在 0.5 的内模里,训练起点收权限学出的是贴 clip 的 另一套步态,对 plant 差异零余量"). Result: the policy was withdrawn before hardware ("撤回——不上真机"), the lineage root moved back to the 0.5-contract s1c-5500, and this became the C ladder's cited fact-check ("s1g 是 0/20 证伪出局的那一代").
Change
The amplitude-surgery route abandoned; contract kept at scale 0.5; the deploy-side 0.8 crutch later retired on its own merits when the delay-complete s1e generation ran at full power.
Outcome
One training run bought a clean falsification of a plausible algebraic identity; no hardware time was spent on it because the sim2sim gate caught it.
Mechanism
Output scaling commutes with the network arithmetic but not with learning: the training-time scale shapes which gait solutions are reachable and how much clip headroom the optimum keeps. A derated mature policy retains the wide-authority solution executed softly; a from-zero narrow-authority policy finds a different optimum that saturates its smaller envelope - the two are not the same controller in different units.
Applies when
- proposing to move a deployment derating into a training constant
- a scaled-down contract policy hugs the action clip
- Isaac-green / cross-sim-zero results on a re-scaled lineage
“预注册 a) 证伪——Isaac 全绿(零摔/reward 117)但 MuJoCo --delay 2 八档 checkpoint 扫描全数 0/3、iter6500 20-seed 0/20 … 「s1c@0.8 = 0.4 训练孪生」的代数等价不成立: 部署端打折的策略活在 0.5 的内模里,训练起点收权限学出的是贴 clip 的另一套步态,对 plant 差异零余量。”
train/OMNI_V0_SPEC.md § 3. S1.6 判决(2026-08-07 验收) Design the next run to complete the 2x2 - either outcome then convicts or acquits a factor cleanly
fill-the-missing-factorial-cellWhen two config factors are jointly suspected, lay out the factorial of existing evidence, spend one run on the missing cell with both interpretations and an early-abort tripwire written in advance - and treat either outcome as a verdict, not a disappointment.
Symptom
Hip joints froze at the action clamp in v7, but the history could not say whether the culprit was the raised action_rate (-0.2) or the halved reference amplitude (scale 0.15): existing versions covered only three corners of the (rate x scale) space - v5 (-0.03, 0.30) healthy, v6 (-0.03, 0.15) healthy, v7 (-0.2, 0.15) frozen.
Context
v9 was designed explicitly as the missing cell (-0.2, 0.30), with the readings pre-registered: v9 not frozen -> the real anti-freeze force was always the reference amplitude and -0.2 may stay; v9 frozen -> -0.2 is convicted beyond appeal (freezes at both amplitudes) and the next version goes straight to a structural fix. "两个结局都是干净的信息" - both endings are clean information.
Change
One training run allocated purely to complete the factorial, with freeze tripwires (joint_pos_ref telemetry <0.1 at iter 1000-1500 -> abort, do not run to 6000) so a conviction costs the minimum compute.
Outcome
v9 froze - the rate weight was convicted at both amplitudes ("−0.2 铁案定罪"), and v10 moved to the structural saturation fix with the weight question closed instead of re-litigated.
Mechanism
Three corners of a 2x2 leave the two factors confounded in the failure corner; the fourth observation makes each factor's marginal effect identifiable. Pre-registering both readings turns the run into a guaranteed-informative experiment regardless of outcome.
Applies when
- two config changes are confounded in a failure
- version history already covers some corners of a factor grid
- deciding what single experiment buys the most attribution
“这恰好补齐一个 2×2 实验矩阵的缺格 … v9 不冻 → 真正的抗冻结主力一直是参考摆幅,−0.2 可以留;v9 仍冻 → −0.2 铁案定罪(两种摆幅下都冻),v10 直接上结构修复 … 两个结局都是干净的信息。”
train/WALK_V9_SPEC.md § 0. 设计原则 (2×2 实验矩阵) Curriculum-gate a penalty to the phase where its disease occurs - early on it only taxes exploration
gate-penalties-to-the-disease-phaseFor penalties aimed at late-stage pathologies (freezing, saturation, degenerate attractors), ramp the weight in only after exploration noise has decayed; anchor the terminal weight to measured healthy-vs-sick raw values, and shift all related tripwires to after the ramp completes.
Symptom
The action_saturation penalty, applied from iteration 0 in v8a, taxed exploration itself: with init_noise_std 1.2 the sampled actions paid ~-2.45/step before any policy had formed - while the disease it targets (clamp freezing) is a LATE pathology (v9 froze at iteration ~2624).
Context
v10 re-introduced the same penalty behind a curriculum gate: weight 0 until iter 1000, ramping linearly to -1.0 by iter 2000 - present only when the disease can occur, absent while exploration noise dominates. The trust argument was evidence, not hope: in v8a the term, while active, had pulled joint_pos_ref from 0.041 up to 0.155 and climbing - proof it can extract a policy from the frozen pit. Weight magnitudes were anchored to measured raw values (healthy v5 0.310 / v6 0.106 vs frozen v7 1.145 / v9 1.22 per step: at -1.0 healthy pays 6-18% of tracking, frozen pays 60%+, standing ~0). v10c then isolated the gated term as THE anti-freeze mechanism by single variable, upgraded to untouchable status in v11: "S 的门控机制(v10c 单变量铁案:任何情况下 不许撤,只许调终值)" - and v11 dared to relax other penalties only because S stood guard.
Change
action_saturation gated 0 -> -1.0 over iters 1000-2000 (later terminal value tuned -1.0 -> -0.5 with the gate mechanism itself frozen); tripwires adjusted to respect the gate's timing (freeze check moved to iter 2500-3000 to give the ramped term its effect window).
Outcome
Freezing stopped recurring while early training kept full exploration; the mechanism graduated from experiment to invariant within two versions.
Mechanism
A penalty's incidence depends on who occupies its support: early in training that is exploration noise (whose suppression starves learning), late it is the converged pathology. Time-gating aligns the penalty's presence with its target's presence, buying the constraint without the exploration tax - and tripwire timing must then be computed from the gate schedule, not from ungated precedents.
Applies when
- a structural penalty punishes exploration in early training
- a late-onset pathology (freeze/saturation) needs a standing guard
- deciding when a curriculum ramp should engage
“v8a 实锤它的病根是"罚在采样动作上"——init_noise_std 1.2 的早期等于罚探索(~−2.45/步);而冻结是晚期病(v9 速率 2624 才死平)… 门控让它只在病发期在场。… v8a 里它在场时 joint_pos_ref 从 0.041 爬到 0.155 且仍在升——有从低谷爬出的实证。”
train/WALK_V10_SPEC.md § 2. S 保险 —— action_saturation 课程门控 Before training a one-leg stand, the accounts and a probe showed the default gains could not hold it at all - kp 20 needs 0.39 rad of error to carry the static roll moment, more than the whole adduction range - so per-joint gains came first, and thermal limits set the session length
single-support-gain-authority-probeBefore training a posture that loads one joint statically, compute the steady tracking error load/kp and the series stiffness against m*g*h, and prove with a simple hand-written controller that the posture can be held under the deployment gains - change the gains first if it cannot; then size session length from the thermal account.
Symptom
The one-leg line (standing on one foot, the other folded back, no hopping) had to decide whether the existing gain profile could hold single support before any reward was designed.
Context
Hardware accounts (9.792 kg, COM 0.234 m high, 170 x 80 mm feet, legs 80% of the mass): moving the COM over one foot needs 107 mm of shift and the 20 deg hip-roll adduction range gives 131 mm - geometrically enough. The static frontal moment is 7.8-9 N*m, within RS02's 17 N*m - torque is enough. But at kp 20 carrying 7.8 N*m needs 0.39 rad of tracking error, more than the entire adduction range, and the real robot had already shown it: commanded +0.17, actual -0.04 (0.21 rad droop) under load, 0.0008 rad hanging - load, not the motor. A probe (probe_oneleg.py) then showed open-loop PD cannot hold single support on physics grounds, so the criterion became "an equilibrium exists and a hand-written 4-gain COM feedback can hold it": single-support roll stiffness is hip and ankle in series and must exceed m*g*h_com = 22.5 N*m/rad; ankle kp 12 in series with hip kp 80 gives only 10.4 (open loop 16/16 fell), ankle 60 with hip 80 gives 34.3 (52% margin).
Change
A per-joint gain profile (rl_oneleg: hip_roll kp 80, ankle_roll kp 60, the rest as rl_default) - which needed per-joint gain support in robot.yaml, the bridge, deploy and the trainer's actuator groups - decided before training. Thermal account: single support makes hip_roll the dominant heat load (about 7.8 N*m against a 7 N*m continuous rating), so acceptance and demos run in segments of at most 60 s with a temperature check.
Outcome
Under rl_oneleg the hand-written feedback held six cells cleanly for 6 s (hip_roll steady torque 2.1-3.4 N*m, half the thermal budget); under rl_default the same feedback on the same cells fell 0/4. The trained V0 policy then passed its 40-cell acceptance.
Mechanism
With PD position control, the steady error needed to carry a static load is load/kp; when that error exceeds the joint's range the posture is unreachable whatever the policy does, and series compliance between joints lowers the effective stiffness below the gravity stiffness that single support demands.
Applies when
- single-support, crouched or one-arm-load postures on PD actuators
- a joint "droops" under load on hardware but tracks well when hanging
- deciding whether a new skill needs its own gain profile
“但 kp=20 时撑住 7.8 N·m 需要 **0.39 rad 跟踪误差 > 整个内收行程**。真机已实测: 命令 +0.17 实际 −0.04(droop 0.21 rad),悬挂时 0.0008 rad——是负载不是电机。 … 单支撑滚转是 hip/ankle **串联**刚度,必须 > m·g·h_com = 22.5 N·m/rad;ankle kp12 串 hip80 只有 10.4(开环 16/16 全摔),60 串 80 = 34.3(裕 52%) … **rl_default 同反馈同格 0/4 全摔**(增益档必要性对照)”
git:Lucen V2@origin/oneleg-line:train/ONELEG_V0_SPEC.md § §1-1 单脚站: 几何可行,卡点是 hip_roll 增益权限 / §2 A 线增益 / §5 probe 定谳 A torque-tail penalty was paid for by bracing the legs against each other - the second simulator's leg-contact count caught it, and the first explanation ("the trainer can't see self-collision") was retracted from the run's own config
torque-penalty-bought-by-leg-bracingWhen a penalty lowers a demand metric, look for what the policy traded to get there - keep self-contact frames and foot spacing as standing sim2sim readouts - and check any "the trainer cannot see X" explanation against the run's resolved config before it enters the record.
Symptom
After R3.1's torque_headroom term collapsed the demand tail, MuJoCo success fell 100 -> 98% and leg-leg contact frames at mu 1.0 rose 750 -> 2,190 (worst rollout 177 -> 450). The one failure (prone seed 2) had the legs crossed, one foot on the other leg, trapped at 0.067 m - visible on video.
Context
Across the ten prone seeds, foot spacing and leg-leg contact frames were monotonically anti-correlated, and the failure was the extreme of the series. Pulling the legs toward the midline shortens the hip_roll lever arm and lowers torque demand. At the time the spec explained it as Isaac training without self-collisions ("a free lunch in a simulator without self-collision").
Change
Leg-leg contact frames and foot spacing were tracked in every MuJoCo gate; R3.2's candidates were "train with self-collision on" or "a minimum leg spacing term" - not stacked.
Outcome
The next rung's joint-velocity penalty incidentally erased the dependency (2,190 -> 86 frames). On 08-10 the runs' logged env.yaml showed enabled_self_collisions true in both r3_1 and v2_2 (inherited from walk v10): the tangle was physically learned bracing, visible to both simulators, and the Isaac/MuJoCo contact-count gap was mesh and contact fidelity. The "self-collision debt" narrative was withdrawn for the whole line.
Mechanism
A penalty on demand rewards any configuration that lowers demand; legs pressed together act as a mutual support that fails when contact geometry shifts slightly.
Conflicts
§24 attributes the dependency to self-collisions being disabled in training; §36 retracts that from the runs' env.yaml ("§24's mechanism explanation was wrong") and keeps the older sections unedited as history.
Applies when
- a torque, impact or energy penalty improves its metric and cross-sim success drops
- legs or links approach each other after a regularization change
- an explanation relies on a simulator setting nobody checked in the run config
“prone 十个 seed 逐条看,脚距与腿-腿接触帧数单调反相关, 而唯一失败的那条正是最极端的一条 … 机制上说得通:把腿收到身体中线附近能缩短 `hip_roll` 力臂、降低力矩需求”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §24 代价:MuJoCo 成功率 100% → 98%,病因是两腿卡住 The deploy-side walk/recovery switch - into recovery at tilt > 65 deg held 0.3 s, back at tilt < 15 deg with angular rate < 1 rad/s and straight knees held 1 s, a 15 s timeout, last action cleared both ways - and the handoff steps the design required are only partly implemented
walk-recovery-fsm-handoffSpecify a deploy-time controller switch as hysteretic, time-filtered predicates the robot can measure (proxy what it cannot, e.g. straight knees for height), a timeout that ends in a safe stop, and a complete handoff (history, clock, last action, command ramp) - then test that the code performs every handoff step, because the design document is not the implementation.
Symptom
With a recovery policy and a locomotion policy as separate networks, the robot needs a switch: when is it "fallen", when is it "up", and what state must be reset so the next policy does not act on the previous one's history.
Context
The 08-09 design: enter recovery when fallen (tilt > 55 deg or height < 0.60 x 0.384 m) for 150 ms, leave for a stand-hold when upright (tilt < 12 deg, height > 0.85 x 0.384 m, feet steady, |omega| < 0.8) for 400 ms - wide entry, strict exit, hysteresis - then a mandatory handoff trio before walking resumes (reset the walking policy's observation history, restart its phase clock at 0, clear its previous action and latency buffer) and a command ramp instead of a jump. The 08-14 implementation in deploy_policy (--recovery-policy): each policy under its own manifest contract (walk: nominal + scale; recovery: beta-anchored), the same rl_default gains, the tilt cutoff disabled; RECOVERY at tilt > 65 deg for 0.3 s; LOCO again at tilt < 15 deg and |omega| < 1 and knees straight (< 0.35 rad) for 1 s - the robot's computer has no height estimate, and straight knees stand in for height so a V3.0-style upright kneel cannot pass as standing; RECOVERY longer than 15 s ends in a safe stop; last_action cleared on both switches; command forced to 0 during RECOVERY; power scaling applies to LOCO only.
Change
An open account was written down with it: the recovery end state (0.355 m stance, hip yaw -/+27 deg) is outside the walking policy's training start distribution, so the first test must use stand / zero command as LOCO, and the long-term fix is to widen the walking policy's initial states rather than bend recovery's stance to suit walking.
Outcome
The spec records only a successful compile (py_compile); the hang test was left to be done on site. The operator runbook carries the three-step procedure (hang with stand as LOCO, mat and push, then omni walk as LOCO) but no outcome.
Mechanism
Two policies trained separately each assume their own history, clock and last action; a switch that carries any of them across feeds the next policy a state it never saw - the design called this "the walking policy seeing a ghost history".
Conflicts
The 08-09 design requires resetting history, clock and previous action plus a command ramp; the 08-14 implementation records last_action clearing and a zero command during recovery; the one-leg spec of 2026-09-14 lists the handoff hygiene as specified but not implemented - reset_history() is called by nothing (a 215-dim policy would carry four frames of pre-fall history), the phase clock is not zeroed, and there is no command ramp back to LOCO. No hardware run of the FSM is recorded in either source.
Applies when
- switching between separately trained policies on hardware
- a policy with history or phase observations is re-enabled mid-run
- the robot lacks a sensor the switching criterion was designed around
“**判据**:进 RECOVERY = 倾角 >65°(`--fall-tilt-deg`)持续 0.3 s;回 LOCO = §5 真机可测子集:倾角 <15° ∧ |ω|<1 ∧ **膝直 <0.35 rad(NX 无高度观测, 高度门用膝直代理 —— 防 V3.0 型"跪坐但直立"误判)** 持续 1 s (`--recover-hold`);RECOVERY 单次 >15 s(`--recovery-max-time`)安全停。 … **切换卫生**:两向切换 last_action 清零;RECOVERY 态 cmd 强制 0”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §50 FSM 双策略调度(2026-08-14,用户令):deploy_policy --recovery-policy Order hardware runs by sim risk, gate each stage on the last, and put the fragile cell last with a spotter
risk-ordered-real-deploymentScript hardware sessions as a risk ladder: baseline first, sim-riskiest last with a spotter, suspended smoke before ground, each stage gated on the previous, environment (floor mu) recorded as a selection input - and stop at the stage that misbehaves.
Symptom
Five policy-x-gain combinations had to go on hardware in one session, with sim survival ranging from 20/20 down to 17/20 (and zero-command survival down to 2/20) - an unordered session risks breaking the robot on an avoidable run.
Context
The execution sheet fixed the order as sim-risk low to high, control baseline first (current SOTA establishes the floor reference), the fragile cell (fric-2400@kd1.0) last with a person spotting throughout. Stage gating: suspended smoke (feet off ground, 10 s each, all five pass before anything touches down) -> suspended with IMU and forward command (gait forms in the air) -> grounded runs -> speed raise only for combos that survived the previous stage -> zero-command tests only with a spotter, ordered by sim zero-cmd survival, with the 2/20 cell skipped by default. Preconditions include recording the floor material and estimating mu (if mu <~0.6, sim says pick the kd1.2 gain as main), port/CAN self-check, calibration frozen. Any stage failing stops the session at that stage: "任一段出问题就停在那一段, 不要跳到下一段".
Change
Session structured as a risk ladder with per-stage gates instead of a flat checklist; per-combo sim survival numbers written into the run table as the ordering key.
Outcome
The session design localized any failure to the cheapest stage that could reveal it, kept the robot safe for the informative fragile run, and made the control baseline available before any comparison run.
Mechanism
Hardware sessions consume a shared budget (robot integrity, battery, floor time); ordering by predicted risk means information is bought cheapest-first, and stage gates convert an expensive failure into a cheap earlier one. Baselines run first because every later reading is relative to them.
Applies when
- taking multiple policies/configs to hardware in one session
- a candidate is known-fragile in sim but must be measured
- writing a deployment runbook for a new robot
“跑序 = sim 风险从低到高, 最险的放最后 (依据 = 存活门/零指令存活) … ⑤ 是 sim 里最脆的一格 … 放最后跑, 全程留人扶, 起步即给 cmd, 零指令不做。… 任一段出问题就停在那一段, 不要跳到下一段。”
train/REAL_RUN_S2.md § 上机名单 / 全部命令 A real-robot verdict is (policy x deployment stack) - when the stack changes materially, old verdicts expire
stale-verdicts-under-old-stackDate every hardware verdict with the deployment-stack version it was measured under; after any material stack change, re-test before trusting old condemnations or old praises - with the interpretation of each possible result written down first.
Symptom
walk_v5 stood condemned as "kicks wildly" and walk_v6 as "cannot walk unassisted" - but those verdicts were issued under an earlier deployment stack (--heading did not exist yet, several fixes had just landed); only v7 had ever run under the current unified stack.
Context
New sim evidence sharpened the doubt: a same-harness four-version sweep showed v6 was the HEALTHIEST archive at the real operating point (cmd 0.15: dominant frequency locked at 2.50, steps 35:35 perfectly symmetric, foot distance 203/190 mm best of four, mean tilt 4.2 deg, saturation 15%). A full re-test under the unified stack was scheduled with per-version questions and a pre-filled interpretation table ("判读表(预填假设,回来对号)"): e.g. v6 walks + frequency ~2.5 -> old verdict was the stack's fault, v6 becomes the comparison champion; v6 walks but at ~1.25 -> period-doubling on hardware = confirmed plant gap, actuator fitting promoted to mainline; v5 no longer kicks -> the kicking was an old-stack artifact.
Change
All four versions re-queued on hardware under one stack (same torque limits, slew profile, heading loop, logging), with the version-specific legacy profile pinned; verdicts held provisional until re-issued.
Outcome
The re-test design separated policy properties from stack artifacts before any policy was permanently written off - and turned each outcome into a specific conclusion via the pre-filled table.
Mechanism
A deployed behavior is produced by the policy plus everything between it and the motors (heading loop, slew limits, torque caps, clock); verdicts implicitly condition on that whole stack. Fixing the stack invalidates the conditioning, so old failures may be stack artifacts and old successes may not survive either.
Applies when
- deployment tooling (limits, filters, loops) changed since a policy was last judged
- deciding which historical policy is the rightful baseline
- a sim sweep contradicts an old hardware verdict
“只有 v7 在完整的今日部署栈下上过真机 … v5"左右乱踢"、v6"未能自主"的判决全部来自更早的栈(--heading 尚不存在, 部分修复刚落地)——判决已过期。且 2026-08-02 四代同机仿真横测翻出了新证据:v6 在真机工况(cmd 0.15)下是四代里最健康的仿真档案”
train/REAL_SWEEP_V5_V8.md § 0. 为什么重测 Two simulators disagreed 1.8x on one policy's torque demand - four explanations were eliminated with numbers, the surviving suspect was never tested, and neither reading was allowed to cancel the other
torque-disagreement-between-simulators-unresolvedWhen two simulators disagree on a safety-relevant quantity, eliminate the measurement explanations one at a time with numbers, name the survivor as a hypothesis, keep the pessimistic reading binding, and run the direct test (replay one action sequence open-loop through both plants) before the quantity is used to pass a gate for hardware.
Symptom
For R3.0, Isaac read hip_pitch torque demand at 75-80% of the limit (PASS); MuJoCo read the same policy at 148-152% (1.5x over the limit).
Context
Candidates were eliminated one by one: PD gains (identical, RS06 kp 30 / kd 1.5), the settle window (both skip the first 0.5 s), the statistic (worse-of-two-legs vs per-joint - explains ~15%), self-collision (the no-contact subset still read 152%), sampling (500 Hz peak vs 50 Hz sample - ~9%). About 1.8x remained. The prime suspect - Isaac's implicit actuator (PD solved inside the PhysX integration, chosen to mimic kHz firmware PD) against MuJoCo's 500 Hz explicit PD - was named but untested.
Change
The Isaac PASS was recorded as valid for the Isaac plant only; the prescribed decider was an open-loop replay of one action sequence through both plants, compared step by step, needing no training. It was upgraded to a precondition of R3.1.
Outcome
R3.1 ran in parallel with, not after, the replay, and the replay never appears as done. By §40 it was "the oldest open account" on the line, to be fed by real-robot logs - which the spec also never records. Meanwhile the 50 Hz sample under-read the peak by 34% as smoothing narrowed the spikes, so Isaac-side readings grew more optimistic exactly when the comparison mattered more.
Mechanism
Each measurement artifact explained a slice of the gap; what remained is a plant difference, and an untested plant hypothesis cannot license discarding the pessimistic simulator on a safety-relevant quantity.
Conflicts
The spec prescribes the open-loop replay (§23), upgrades it to an R3.1 precondition, then records that R3.1 ran in parallel without it (§24), and lists it as the oldest open account before hardware (§40); nothing through §50 (2026-08-14) records a result. Every later "torque gate PASS" on this line is an Isaac-plant reading plus a MuJoCo check, never a reconciled one.
Applies when
- Isaac and MuJoCo (or sim and hardware) report different torques, contacts or slips
- implicit vs explicit actuator models are in play
- a gate passes on one simulator only
“**同一个策略,一侧判 PASS 一侧判超限 1.5 倍。** … 口径项全部扣掉后仍剩 **~1.8×** 没有解释。 … 但**这条没有验证,不能拿它当结论去抵消 MuJoCo 的读数**。 … (做法:拿同一条 动作序列在两边开环回放,逐拍比 τ —— 不需要重训)”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §23 MuJoCo 复核门:成功率更稳,但 τ 与 Isaac 差 ~1.8× 没收敛 The first real-robot get-up was "very violent, kicking on the floor, dangerous" - a sim-perfect policy with no reason to be slow, unbounded absolute targets, no domain randomization and a rate limiter that filtered nothing; the task was restated as "safe, slow, transferable"
first-real-get-up-violent-stage-one-policyDo not put a get-up policy on hardware until its action is bounded (hard bound or state-anchored targets), smoothed, randomized and tested at the real pipeline's latency, and say explicitly that the task is "safe, slow and transferable" - a simulation-perfect policy optimizes only "gets up".
Symptom
On 2026-08-09 the user ran a V0-lineage recovery policy on the real robot and stopped it: very violent, kicking on the floor, dangerous. The planned next rung (a heavier torque_headroom) was never started.
Context
The spec had pre-registered that R0/R1 products stay in simulation and that the real-robot precondition was the R3 smoothing rungs plus a bridge-slew check plus a hanging protocol; the robustness (DR) rungs had not run. In simulation the policy passed 100% with a get-up of about a second. Which ONNX, which gain profile and whether a torque/joint log existed were left "to be recorded later" and never were.
Change
The V0 ladder was stopped at its best product (R3.1, sim only) and a re-rooting proposal was put to the user. The spec's four-layer account: style (the reward pays for standing early and nothing pays for slowness - HumanUP's "Stage I" get-up, "fast but unsafe ... infeasible for real-world deployment"); impact (full-range absolute targets with no hard bound, raw |a| up to 4.77, action saturation 100%, a single-step change of 0.306 saturating hip_pitch); transfer (zero DR, friction pinned at 1.0, the learned leg bracing); link (the bridge's RL slew equals vel_limit, 0.2-0.66 rad per step, while the real pipeline has 1-2 steps of time-varying latency and acceptance ran at delay 0).
Outcome
The line was re-rooted twice (training-side rate limit, then the beta-anchored action space) and gained a hang protocol before the next real attempt; on 08-11 a beta-anchored policy produced the line's first real get-up.
Mechanism
A task reward that pays for standing early selects the fastest feasible get-up; with absolute full-range targets every large target jump is a torque impulse bounded only by the clip; zero DR and braced-leg solutions do not transfer; and a limiter set at the velocity limit does nothing at 50 Hz.
Conflicts
The four layers are the spec's reconstruction from simulation probes and the literature; the real run's policy file, gain profile and log were never recorded, so no layer was confirmed against hardware data.
Applies when
- a first hardware trial of a high-effort skill is being scheduled
- sim success is high but the policy saturates actions or torques
- pre-registered hardware preconditions are not all met
“用户真机反馈:**非常猛、地上乱踢、危险**,叫停(R3.3 torque_headroom 加档已选型 weight −0.5→−1.5,未启动)。真机细节(哪个 onnx、什么档、有无 τ/q log)**待补记** … 任务从"能起来"变成 **"安全、慢、可迁移"** … **链路层**:桥层 slew RL 档 = vel_limit(10/20/33 rad/s ≈ 每拍 0.2~0.66 rad), 对 recovery 形同虚设;真机 1~2 拍时变延迟,验收默认 delay 0。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §26 真机叫停与换根判决(2026-08-09) A frame-history observation under zero DR memorizes the trainer's plant fingerprint - the estimator must see variation to learn estimation
history-obs-needs-plant-variationIf the observation carries history (stacked frames, RNN), keep at least minimal plant variation (gain/latency jitter) on from the first iteration - "nominal first, robust later" is structurally invalid for estimator-bearing contracts.
Symptom
omni_s1 (fresh 215-dim contract with a 5-frame history window, trained with DR fully off): training all green, yet the MuJoCo gate scored 0/20 on all eight doors - falls within 2 s, seven checkpoints, not one transferred.
Context
The history window exists precisely to let the actor implicitly estimate line velocity and actuator dynamics (the actor is denied base_lin_vel by observation honesty). Under a constant plant that implicit estimator has nothing to estimate - it learns the trainer's exact response fingerprint instead, and any other simulator's micro-differences are out-of-distribution: "5 帧窗按设计就是隐式估计器, plant 恒定时它学到 Isaac 精确响应的指纹". The planned "nominal-first-robust-later" staging was declared STRUCTURALLY incompatible with history observations: "估计器要见过变化才学估计, 否则学背诵" (an estimator must see variation to learn estimation, otherwise it learns recitation). Honest confound note kept: this is mixed with "zero DR does not transfer, period" - but both attributions prescribe the same fix, so no control was run.
Change
S1.1: minimum actuator jitter turned on from day one - kp/kd +/-10%, latency 0-1 frame (friction/COM/mass still nominal, no push - those stay for the S2 ladder).
Outcome
Transfer restored: survival 0/20 -> 20/20, speed 19/20, foot distance 20/20 (remaining failures moved to gait quality, a different disease); the staging doctrine was amended - history-carrying contracts never train under a frozen plant.
Mechanism
A recurrent/history channel fits whatever temporal structure minimizes loss; with a deterministic plant the cheapest structure is the plant's own impulse-response signature, yielding features that are simulator-specific rather than physics-general. Plant variation forces the channel to carry state-estimation features that transfer.
Conflicts
Attribution is explicitly confounded with the simpler "zero DR never transfers" reading ("与「零 DR 本身就不迁移」混杂 … 两种归因处方相同, 不做对照") - the source chose not to spend a control run separating them.
Applies when
- adding frame stacking or recurrence to an actor observation
- a nominal-plant policy fails a cross-simulator gate within seconds
- planning DR staging for a new contract
“frame_hist × 零 DR = plant 指纹过拟合——5 帧窗按设计就是隐式估计器, plant 恒定时它学到 Isaac 精确响应的指纹, MuJoCo 的微小差异即 OOD, 2 s 内摔, 七个 checkpoint 无一迁移。「先标称后鲁棒」的分段与历史观测结构性冲突:估计器要见过变化才学估计,否则学背诵。”
train/OMNI_V0_SPEC.md § 3. S1.1 修订记录 ① The +/-50 mm lateral COM randomization meant to spread the legs coincided with legs pulling IN - rolled back per its own pre-registered contract
com-dr-rollback-on-symptomWhen adopting a DR value that covers no local measurement, write its intent and rollback trigger into the config at adoption time; roll it back as the control arm the moment the symptom contradicts the intent, and promote the symptom's metric into the acceptance battery.
Symptom
After v7 adopted the reference developer's oversized lateral COM randomization (+/-50 mm) explicitly to force leg spread, the real robot's legs narrowed instead - lateral mean 154 mm / closest 107 mm in sim (nominal 214.5), narrower still on hardware with occasional leg contact.
Context
The rollback was clean because the adoption had been honest: the robot.yaml comment recorded the intent AND that the +/-50 value covered no local measurement (only a 16/7 mm measured offset existed; even the prior widening to +/-20 was subjective), plus the reference's own reported side effect (base sway) and the note "这一项要单独跑、 单独归因". When the opposite symptom appeared, v8 returned y to +/-20 mm as the control arm ("要么没起作用、要么帮了倒忙 … 按约定退回做 对照"), kept x/z untouched (a noise-level difference not worth another variable), and named the second suspect: the landing penalty itself, via the reference's own three-link chain (landing penalty -> stance narrows -> spacing penalty needed). A gate lesson was booked in the same table: v7's sim numbers had ALREADY crossed the line (154/107 vs v5's 182/147) - "这个指标本可拦下 v7" - so foot-distance became a standing acceptance row (min >120 mm, zero leg-leg contacts).
Change
base_com_offset_m y: 0.050 -> 0.020 (x/z kept), regenerated through the export tool rather than hand-editing derived files; foot-distance acceptance row added.
Outcome
A borrowed DR lever with no local measurement basis was retired the moment its symptom contradicted its purpose, at single-variable cost; the metric that would have caught it pre-hardware entered the gate.
Mechanism
DR ranges shape behavior through the policy's robustness strategy, which is jointly determined with every reward term; a lever that forces stance width on one robot can be dominated by a stronger narrowing pressure (landing softness) on another. Levers adopted without local measurement must carry their own rollback trigger, because there is no nominal to argue from when they misbehave.
Conflicts
Causality is not fully closed in the source: the narrowing may come from the landing penalty rather than the COM lever ("腿距的第二嫌疑人是 ④ 本身"); the rollback is the pre-agreed control experiment, not a verdict that the lever caused the narrowing.
Applies when
- importing DR ranges or behavioral-forcing randomizations from references
- a DR lever's observed effect contradicts its documented purpose
- a sim metric existed that would have caught a shipped regression
“⑥ 的本意 … 是逼策略把脚分开;真机结果是脚向内收且偶发相碰——要么没起作用、要么帮了倒忙。… 注释当时就写了"这一项要单独跑、单独归因"。现在症状出现了,按约定退回做对照。”
train/WALK_V8_SPEC.md § 3. 改动 C — 质心随机化退回(撤销 v7-⑥ 的 y 项) Deployment power derating damages non-forward axes far more than forward - sweep it in sim before deploying
power-scale-hurts-nonforward-axesTreat deployment power/torque scaling as a plant parameter: evaluate the policy in sim at the exact deployment scale, expect non-dominant axes to degrade first under derating, and either deploy at the training power or train with power randomization.
Symptom
Policies deployed at power-scale 0.8 (a safety derating of commanded torque) looked fine walking forward but were weak at backward and turning, inviting the wrong diagnosis "the skill was not trained well".
Context
Measured repeatedly: on s1e, going 1.0 -> 0.8 cost forward 18% but backward 58%; on C4-ff800, turn tracking was +25%/+40% at pw0.8 vs +75%/+58% at pw1.0, backward 51-52% vs 97-103%, while forward stayed 96-98% at both. Sim evaluation numbers in the plan were all pw1.0, but the robot was being run at 0.8.
Change
Pre-deploy protocol added: sweep the exported policy across power in sim (for PW in 0.8 0.9 1.0: eval_c_matrix --power $PW --seeds 20) and deploy at the first level where both turn directions reach >=50%. For C4 the recommendation was raise the robot to pw1.0 - the sweep showed it nearly free (saturation 47%->33%, left foot-clipping danger zone 25%->6%, cost only tilt 6.7->8.3 deg).
Outcome
Turning "weakness" resolved without any retraining; the sim sweep correctly predicted the real-robot signature at both power levels.
Mechanism
Forward walking is the reward-dominant, torque-cheapest skill with the most margin; backward/turn/sidewalk live closer to the torque envelope, so a uniform torque derating consumes their margin first. Training ran at power 1.0 (the trainer does no power scaling), so deploying at 0.8 is a systematic underactuation the policy never experienced.
Applies when
- deploying with any torque/power derating or safety scale
- secondary skills (backward, turn, lateral) underperform on hardware while forward walking looks fine
- choosing the deployment power level for a new policy
“power 衰减对非前进轴的伤害远大于前进轴(s1e:前进 1.0→0.8 掉 18%,后退掉 58%)。转向是非前进轴,0.8 下很可能明显跟不动。”
train/C_LADDER_RUN.md § 3c. A-2 上机前先定部署力度档 / 3p. 二 Fall recovery was defined as the whole chain - any fallen pose, a stable stand, a clean hand-back to walking - and built as a second policy behind a deploy-side switch, not folded into the walking PPO
recovery-two-policies-and-a-state-machineDefine a recovery skill by the whole chain it must complete, including the hand-back to the next controller; if it is built as a separate policy, make the switching logic and its handoff contract a deliverable of their own, and keep the recovery observation contract a subset of the locomotion one so a unified policy stays possible later.
Symptom
A walking robot that falls needs a human to stand it back up. The design question on 2026-08-09 was whether to teach getting up inside the existing omni walking policy or beside it.
Context
The user set the goal as "any fallen pose -> stand up alone -> stand stably", and the spec named the real difficulty as the full chain fall -> recovery -> stable stand -> correctly initialised walking history and clock -> walking, making the deploy state machine a first-class deliverable. A unified single policy had a real-robot precedent (arXiv:2605.18611, a state-dependent gate near 37 deg tilt) but was deferred until a recovery policy and an omni policy were each reliable. The line ran on its own branch and worktree with every walk/stand/omni/run config path untouched. The development path copied the G1 learned get-up logic (arXiv:2502.12152): first find any feasible get-up (ugly accepted), then add smoothing, torque and real-robot constraints. The recovery contract kept the base 45-dim observation (command slice held at 0, no gait phase, no frame history - their reasons do not apply to a skill without a clock or a velocity task), so it stays a prefix of the 215-dim omni contract and a later merge is not foreclosed.
Change
Two policies and a deploy-side switch instead of one retrained walking policy; recovery got its own minimal contract (45 dims, full-range action, later the beta-anchored profile) and its own acceptance battery.
Outcome
The split held for the whole line: on 08-14 deploy_policy gained a second (PolicyIO, ONNX) pair behind --recovery-policy, each loaded under its own manifest contract, and the runbook runs stand_v1b or omni_c4_ff800 as the locomotion side with recovery_v3_1p1c. The literature scan of 08-10 found that every verified get-up implementation deploys one end-to-end policy (or softly gated experts) and stages only on the training side - so the runtime state machine here is the walk/recovery switch, not a staged get-up.
Mechanism
A separate policy keeps each reward table single-purpose and lets a proven walking lineage stay byte-frozen; the cost moves to the handoff, where every piece of state one policy leaves behind (history, clock, last action, command) must be reset for the other.
Applies when
- adding fall recovery or get-up to a robot that already walks
- choosing between one unified policy and a switched pair of policies
- designing the observation/action contract of a secondary skill
“先做 recovery policy + omni policy 两个策略,部署侧状态机切换;不把 recovery 硬塞进现有 omni PPO。 … 任务定义:**任意跌倒姿态 → 自己站起来 → 稳定站立**。真正的难点不只是"起身", … omni walk**(§6 部署状态机是本 spec 的一等公民,不是附录)”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §0 目标口径与架构判决(用户 2026-08-09 定) A single-signal contact detector lied in both directions - foot height flagged 40% false flight on a walking gait, contact force alone flagged false flight during low-friction slip - so flight became force < 5 N AND sole height > 5 mm
contact-detector-single-signal-liesDefine contact and flight events from two independent signals (force and geometry) in conjunction, validate the detector on a behaviour known not to contain the event before using it as a gate, and match the trainer's threshold when comparing across simulators.
Symptom
The run line needed a flight-fraction gate. The first MuJoCo version, "sole higher than 2 mm", measured 40% flight on a walking policy that never flies. Five weeks later the one-leg gate, using contact force alone, reported support-foot "flight" segments at mu 0.4 for a policy that was not hopping.
Context
During a walking step the toe lifts or the heel strikes with the foot pitched, so the ankle-roll origin rises a few mm while part of the sole still touches - height alone calls that flight. Switching to contact force < 5 N (the same threshold Isaac's contact reward uses) zeroed the false flight on walking. In the one-leg re-test every force-only "flight" segment had a measured sole height of 0.0 mm: the normal force chattered while slip corrections played out on low friction.
Change
Run line: flight = contact force < 5 N ("lift-off must be judged by contact force"). One-leg line (2026-09-16): flight = force < 5 N AND sole height > 5 mm, recorded as the same measurement lesson in the opposite direction; the gate's behavioural meaning was unchanged.
Outcome
With force-based detection the walking policy read 0.0 flight and the run policy's zero flight was confirmed by two plants; with the conjunctive definition the one-leg support-foot gate stopped reporting false hops.
Mechanism
Each signal has its own failure: geometry moves without leaving the ground (foot pitch), and forces drop without leaving the ground (slip chatter); requiring both removes both families of false positives.
Applies when
- writing a flight, lift-off, hop or slip detector for a gate
- a gate reports an event the video does not show
- reusing a detector on a different gait or floor friction
“首版用**足底高度>2mm** 判离地, 在 omni_s1e 走路策略上测出 40% 假腾空 … 改用**接触力 <5N**(与 Isaac feet_contact_number 同源阈值)后 空检归零 (walk 策略 flight_frac 0.0)。**课文: 离地判定必须用接触力, 高度判 会把脚的俯仰当腾空**”
train/README.md § run R1 立项 (2026-08-09): Mac 侧新工具 + 一次空检抓获 The run policy never left the ground and fell in the second simulator from the frontal plane - its DR (gains and latency only) covered the actuator axis, not the frontal-plane contact and inertia disturbances the doubled stride amplified; "is DR on" is the wrong question
thin-dr-judged-by-channel-coverageJudge a DR recipe by whether its randomized terms cover the channel where the skill can lose stability, not by whether DR is enabled; when a new skill lengthens single support or enlarges motion in one plane, add disturbances in the plane it destabilizes before training.
Symptom
run R1 (6,000 iterations, 78 min): no flight phase ever appeared, and every one of 13 checkpoints failed the eight-gate MuJoCo smoke. In Isaac: zero terminations in 6,000 iterations, 4.2 deg tilt. In MuJoCo at delay 2: 1/6 survived, falls within 1.9-6.2 s at 50.8-58.7 deg, the most saturated joints all roll joints.
Context
The run contract doubled sagittal travel (knee action scale 0.9, knee swing peak 1.14 rad) with a 0.60 s period and 0.40 duty - long single support - while roll/yaw scales were deliberately left at 0.5. DR copied the s1e recipe: kp/kd (0.9, 1.1) and latency on; mass, COM, joint friction and push all off; ground friction pinned at (1.0, 1.0). Flight was read two independent ways: Isaac's per-foot contact reward stayed 0.845-0.857, never above 0.87 - the arithmetic ceiling of a gait with zero flight - and 30 of 36 MuJoCo seeds had flight fraction exactly 0 (the nonzero six were all tumbling falls). Foot lift itself worked (46-59 mm against a 50 mm design point): the walk-era "not enough travel" failure did not recur.
Change
Verdict FAIL, with the pre-registered first knob (exploration noise 1.0 -> 1.2) explicitly rejected as aimed at a different axis. The lesson was generalized and applied at the next line's design review: the one-leg spec made push, body mass, base COM and friction DR mandatory for its permanent single support and banned the thin recipe.
Outcome
The run line did not continue past R1 in the sources. The one-leg V0 with the wider DR passed its friction-variant gate (mu 0.4 and 1.2) inside a 40/40 acceptance.
Mechanism
Randomizing gains and latency covers the actuator's axis; a skill whose failure lives in frontal-plane contact and inertia needs randomization on that channel (push, mass, COM, friction), or the trainer's exact plant becomes the only one the policy can stand on - the omni_s1 transfer trap a second time, this time with DR switched on.
Applies when
- a policy is flawless in the trainer and falls immediately in a second simulator
- reusing a DR recipe from a skill with a different support pattern
- failures concentrate on one axis (roll, yaw) the DR does not touch
“**机理**: 矢状面行程翻倍 (膝摆动峰 1.14 rad) + T 0.60 + duty 0.40 的长单支撑, 把额状面扰动放大了一个量级; 而 roll/yaw 通道按 §3 **刻意没有放大** (仍 0.5), DR 又是 s1e 复刻的薄配方 (mass/COM/关节摩擦/push **四关全关**, 地面摩擦钉死 (1.0, 1.0))。 … 说明**薄 DR 的判据不能只看"有没有开 DR"**, 要看**开的那几项 是否覆盖失稳所在的通道** —— kp/kd 与延迟是执行器轴向的, 对额状面接触/惯性 扰动零覆盖。 … 0.87 正是「零腾空的走路步态」的天花板算术”
git:Lucen V2@origin/run-line:train/README.md § run R1 FAIL (2026-08-09, run 21-30-30_run_r1): 腾空零, 但病根在额状面不在探索