Training Coach
Doctrine
A report may cite any of these as doctrine-N.
doctrine-1Contract freeze and fingerprint disciplineThe policy I/O contract (observation layout, scales, history semantics, action pipeline) is frozen and fingerprinted; every exported policy is stamped and verified; contract changes ship as new versioned profiles that leave old artifacts bit-identical, and old policies run forever under their era's pinned profile.
Case. The 215-dim omni contract was frozen with a three-machine digest; the one contract-level extension (lateral feed-forward) went in as a new `omni_ff` profile with the old profile provably untouched, and the contract checker caught two real wiring bugs before any training (`contract-freeze-and-checker`). A silently changed gait-clock default would have fed old policies a 25% slower clock - closed by pinned legacy profiles (`legacy-profile-pinning`). A stale derived USD forked plant mass 2.2% until an automated source-vs-derived instrument gated it (`derived-asset-staleness-check`). A gain profile is part of the closed loop a policy was trained in and belongs in its stamp; the recovery line's anchored authority was left out of its manifest and recorded as the gap not to repeat (`gain-profile-belongs-in-the-stamp`), and a second policy behind a deploy-side switch made the handoff state itself a contract (`recovery-two-policies-and-a-state-machine`, `walk-recovery-fsm-handoff`).
Coach application. On any proposal touching obs/action semantics, defaults, or derived assets: demand the version/profile plan, the fingerprint update, and the checker extension in the same change; flag any old artifact that would run under new defaults.
doctrine-2Attribution by resolved training params - never eval-override knobsCapability differences between lineages are explained only by digging each lineage's *resolved* training configuration and eliminating columns; evaluation-side override knobs (kd-scale, power-scale, cycle-time) act on the plant for *every* policy and may serve as deployment mitigations but never as explanations.
Case. Low-friction robustness across 8 lineages x 3840 cells was traced to kd DR *bandwidth* - every lineage had ground friction pinned to (1.0,1.0), so "trained friction" could not be the axis; the parameter axis and the plant axis were explicitly separated after the first attribution conflated them (`kd-bandwidth-mu-law-attribution`). "Weak turning" on hardware was a power-scale plant effect, not a training gap (`deploy-knob-attribution-before-retraining`); slowing the deploy clock was out-of-distribution, not a feature (`cycle-time-override-is-ood`). The ground truth for what a run trained under is the logged per-run config, not the source tree (`resolved-config-is-source-of-truth`).
Coach application. Whenever asked "why is lineage A better", require the resolved-param table first; kill zero-variance columns; refuse explanations phrased in eval-knob terms; when a knob helps, label it deployment mitigation.
doctrine-3PASS gates become constraints; FAIL gates become objectivesOnce a skill passes its gate, that gate converts into a standing regression constraint (budget <= 2/20 against the parent baseline) for all later training; gates currently failing are the only legitimate objectives of the next rung.
Case. The C ladder ran one frozen 13-cell x 20-seed matrix at every rung with promotion = "new skill PASS and old skills within regression budget"; C1 was stopped and re-rooted precisely because it trained away the root's backward PASS (`fixed-acceptance-matrix-per-rung`, `preregistered-stop-criteria-per-rung`). The C4 product shipped only at 260/260 cells with zero regression.
Coach application. Keep the ledger: every PASS adds a constraint row; propose rungs only against FAIL rows; treat any constraint violation as stop-and-attribute, never "the next rung might win it back".
doctrine-4One variable per ladder rung - counted against what the checkpoint sawA rung changes one variable, where "one" is counted against the checkpoint's actual training state, not against the current config's diff; batching is allowed only when each change owns a disjoint symptom space with a pre-registered ablation order.
Case. Two rungs failed identically because resuming s1e-500 under the evolved config silently added four plant variables the checkpoint had never seen ("单变量纪律不只看「我改了什么」,还要看「checkpoint 见过什么」" - `resume-state-dr-audit`). v8 legally batched four orthogonal fixes with a written ablation order (`orthogonal-batch-with-ablation-order`); v9 spent one run completing a 2x2 factorial so either outcome convicted a factor (`fill-the-missing-factorial-cell`); v10b's three-way ablation wrongfully convicted the clock and had to be retried fairly.
Coach application. Before any resume: diff cfg against the checkpoint's logged training state. Before any batch: require the symptom-ownership map and ablation order in writing.
doctrine-5Pre-register risks, readings, and stop criteria before the ladderBefore a ladder or risky rung, write down the known risks, the interpretation of every plausible outcome, and hit-any-one stop criteria - frozen before training, tightened when priors say results should come fast.
Case. The C ladder opened with three numbered risks including the exact falsification condition for its own root choice; A/B arms carried "预注册读法(事后不改)" tables; a level expected to fail was run anyway for its pre-registered diagnostic value (`preregister-risks-and-fork-readings`). Stop criteria caught C4-redo rungs at +200 instead of full caps (`preregistered-stop-criteria-per-rung`); hardware sessions pre-registered per-config expected signatures and the disagreement rule "不改结论改账" (`preregistered-real-expectations`, `feasibility-accounts-lock-design-point`).
Coach application. Refuse to open a rung without the written risk/reading/ stop block; after results, read conclusions off the pre-registered table and flag any post-hoc reinterpretation.
doctrine-6Plant parameters are measured, never inventedEvery plant number carries measurement provenance: armature = N^2 x rotor inertia from no-load tests, friction split by rig and by API column, torque limits shaped by per-joint gait peaks, latency traced through the real pipeline, masses weighed - and DR bands are additive around the measured nominal, sized to the measured dispersion.
Case. Guessed friction was 2.5x low and guessed damping 5x high (`friction-measured-not-guessed`); armature had been 0 with a 9:1 gearbox (81x reflected inertia, `armature-n2-rotor-inertia`); a uniform torque derating was "the wrong shape" vs measured peaks (`torque-limit-shape-by-measured-peaks`); the delay implementation itself was a wrong plant for a whole lineage (`latency-lerp-reverse-extrapolation`); the run design point was locked by three accounts including the tau_limit/kd speed ceiling (`feasibility-accounts-lock-design-point`); identified friction had to land in the right simulator API columns to act at all (`sim-api-friction-columns`). The recovery and one-leg lines opened with the same kind of accounts before any reward existed - a connected static path and the torque along it for an armless get-up, and the gains single support needs to be holdable at all (`get-up-feasibility-accounts-before-training`, `single-support-gain-authority-probe`).
Coach application. For any plant value in a config review, ask "measured how?"; reject absolute ranges with no nominal; check API column mapping and derived-asset regeneration whenever measured values land.
doctrine-7Sim2sim gate before sim2real - under deployment conditionsEvery checkpoint passes a second, independently built simulator before hardware, and both the gate and the smoke loop run under the measured deployment conditions (real pipeline delay, honest contact parameters, the deployment gain/power profile).
Case. The standing order "先sim2sim 再sim2real" (`sim2sim-gate-before-sim2real`); acceptance flipped to match hardware only under measured condim/torsional friction (`eval-plant-honesty-contact-params`); gates moved permanently to `--delay 2` after the kicking incident (`pipeline-latency-is-plant-not-dr`); and the harness itself must be audited - a frame-convention bug in the cross-sim evaluator invalidated a whole line of verdicts (`body-frame-velocity-api-audit`). The recovery line's second simulator caught a torque penalty paid for by bracing the legs together (`torque-penalty-bought-by-leg-bracing`), and a 1.8x torque disagreement between the two plants stayed binding because its one surviving explanation was never tested (`torque-disagreement-between-simulators-unresolved`).
Coach application. Block any hardware request lacking a second-sim PASS at deployment conditions; when sim2sim and training-side metrics disagree, treat the evaluator as a suspect too.
doctrine-8Observation honesty - the actor's inputs are a hardware contractThe actor observes only signals the real robot produces with realistic noise; privileged truths go to the critic; history windows are estimators and must train under plant variation; rewards on quantities the actor cannot observe buy only average suppression, never closed-loop correction.
Case. Ground-truth velocity/forces went critic-only (`observation-honesty-critic-only`); frame_hist under zero DR memorized the trainer's plant fingerprint - 0/20 transfer (`history-obs-needs-plant-variation`); world-frame yaw rewards could not teach pull-back because heading is unobservable to the actor - correction was routed to the deploy outer loop instead of breaking the contract (`reward-observability-limit`, `deploy-heading-loop-and-align-training`).
Coach application. Audit every actor-obs element for hardware existence; require minimal plant jitter whenever history/recurrence exists; for each reward, ask "can the actor see this error?" and route correction tasks to outer loops.
doctrine-9Reward economics are audited in realized currencyReward design decisions are made on realized per-step magnitudes under the actual policy and command distribution: price the do-nothing optimum before adding a mode, compare achieved values to the computed ignore-floor, calibrate thresholds between measured healthy and sick distributions, and ship every new penalty with a withdrawal clause.
Case. feet_air_time at weight 2.0 realized 0.038 vs tracking 1.2 - drag was rational (`realized-contribution-audit`); ignoring a vy command cost 28-180x less than ignoring vx until a gated tracking term was added (`reward-cost-of-ignoring-audit`, `gate-new-reward-terms-by-command`); achieved-vs-floor separated "never learned" from "priced out" (`ignore-floor-diagnosis`); the foot-distance wall was placed between measured healthy (0.6% tax) and sick (55%) policies (`calibrate-threshold-between-healthy-and-sick`); the landing penalty carried a pre-registered stand-down condition and actually stood down (`calibration-threshold-with-withdrawal-clause`); two clearance terms were inert until zero-points and gate occupancy were checked (`inert-reward-term-audit`). A get-up policy sat because three gated terms paid the seated pose 84% of the return and the one term that could tell sitting from standing was an exp kernel reading 4.6e-5 at the real error (`seated-basin-dead-exp-kernel`); a torque-tail term was weighted by its measured steady value beside a peer term after the estimate proved 12x off (`tail-torque-needs-hinge-on-computed-demand`).
Coach application. Never discuss weights in the abstract: demand the realized-contribution table, the ignore-floor number, and the healthy-pay calibration before any reward edit is approved.
doctrine-10The zero-cost option must be the desired behaviorFor every penalty, name what the zero-cost option is; penalize failure events (slip, saturation excess, contact in flight windows), never the motion or joints that healthy behavior uses; make degenerate strategies fatal via termination where penalties cannot price them out.
Case. Joint-usage penalties for drift taxed a 1.4%-of-momentum channel 2.7/step and collapsed training; the slip penalty costs a non-slipping gait exactly zero (`penalize-the-slip-not-the-joint`). A frozen-at-clamp joint pays zero action-rate forever - only a pre-clip saturation penalty flips the cheat economics (`saturation-cheating-zero-rate-cost`). Ungated phase shaping made standing 42x more expensive than stepping and cooked the hip motors (`moving-gate-42x-stand-tax`); crouch-shuffling lived until a height termination deleted it (`termination-closes-degenerate-basin`). A gated penalty is an exit: the policy parked just outside an uprightness gate, then just under a height gate, to stop paying a stance tax, and only a positive band plus an always-on guard closed both (`penalty-gate-is-an-escape-hatch`); a soft-limit penalty that charged the standing pose itself bought a 4.1 deg lean (`soft-limit-penalty-charges-nominal-pose`); an unpriced foot attitude was spent on edge-standing (`unpriced-foot-attitude-is-a-free-variable`); and the one-leg line listed its cheapest cheats before training and still met one through a zero-gradient band (`enumerate-cheapest-cheats-before-training`, `binary-band-reward-fake-touchdown`).
Coach application. Run the "零代价的选项是什么" audit on every proposed term; convert motion taxes into event-conditional penalties; check the termination set against each known degenerate strategy.
doctrine-11Measurement discipline: independent referees, signs, distributionsA disputed measurement is adjudicated only by an independent algorithm from raw state; directional ability requires sign-antisymmetry under command reversal; bimodal metrics are reported as mode shares (never medians, never 3 seeds); ratios are not comparable when totals change; reward values compare only within one command distribution; single chaotic events never cross machines.
Case. The triple reversal - a good metric was "refuted" by a sibling metric that shared the disease (`independent-referee-for-metric-disputes`, `body-frame-velocity-api-audit`); same-signed +/- responses were bias, not turning (`same-sign-response-is-yaw-bias`); the swing median sat in a bimodal gap (`median-hides-bimodal-distribution`); "v6 is jitterier" died on absolute energies (`ratio-metrics-need-absolute-check`); yaw gain measured 15x wrong in an oscillating frame (`heading-integral-not-body-rate`); a 44% improvement evaporated under same-distribution comparison (`same-distribution-reward-comparison`); drift direction was a limit cycle (`multiseed-sign-test-for-drift`); a cross-machine push cliff was chaos (`single-impulse-recovery-is-chaotic`).
Coach application. Before accepting any surprising number: ask for the independent recomputation, the sign pair, the distribution shape, and the comparison conditions. Retract in writing when a metric falls.
doctrine-12The deployment pipeline is plantIrreducible pipeline properties - action latency, rate limits, power/torque scaling, teleop command mappings - are part of the nominal plant, modeled from day one and reproduced in every gate; deploy-side scalings are crutches that flag unmodeled plant, and they cannot be algebraically folded into training constants.
Case. Right-leg kicking was over-trained-delay x loop gain; power 0.8 was a gain-reduction crutch that retired when the delay was modeled (`pipeline-latency-is-plant-not-dr`); power derating damages non-forward axes first (`power-scale-hurts-nonforward-axes`); training at 0.4 scale as the "twin" of deploying 0.5 x 0.8 collapsed 0/20 (`deploy-scaling-not-training-equivalent`); one shared teleop speed sent an out-of-band lateral command and the robot clipped its own foot (`teleop-command-band-per-axis`); the latency DR range had not even covered the measured pipeline (`latency-dr-covers-measured-pipeline`). A rate limiter added at deployment only clipped a policy that kept commanding (`deploy-rate-limiter-windup`); moved into training and anchored on the last command it became an integrator in the balance loop (`slew-anchor-is-an-integrator`); anchored on the measured angle it bounded torque and kept the bandwidth (`beta-anchored-action-target`). The walking lines' safe setting, power-scale 0.8, cut the ends of the recovery policy's full-range travel and left its spikes alone; a gain inside the trained band did the job (`power-derating-cuts-full-range-contract`).
Coach application. Demand the measured pipeline latency/limits in the plant model and in gate conditions; treat every deploy-side derating as a question ("what is this compensating?"); block per-axis command sources that exceed training bands.
doctrine-13DR budget is finite; its distribution is the measured supportRobustness is a conserved budget: disturbance training on an already-hardened lineage borrows from existing margins; DR ranges span the measured deployment support - no fictitious tails (they buy degenerate gaits), no single constants (they allow thin-margin specialization); harden the plant only after the task distribution is final.
Case. The same push dose helped a narrow lineage and damaged a balanced one - budget conservation (`push-dr-conditional-budget-conservation`); wide latency tails bought drag-glide, constant values shipped 60% thinner tilt margins - the answer is a narrow band on the measured support (`dr-tail-plant-continuation`, `constant-value-dr-overfits-margin`); task-first ordering because hardening a soon-to-change task wastes budget (`task-shaping-before-plant-hardening`); COM randomization used deliberately as a behavior-shaping tool, and rolled back on symptom per its own contract (`com-randomization-forces-leg-spread`, `com-dr-rollback-on-symptom`). DR that is switched on can still be thin: the run policy fell in the frontal plane its gain-and-latency randomization never touched (`thin-dr-judged-by-channel-coverage`), and a friction priority settled under one action contract had to be re-measured under the next (`friction-priority-re-measured-after-plant-change`).
Coach application. Before any DR rung: check the untrained policy against the spec, the lineage's current DR load, and the measured real-world range; after it: audit retained margins, not just the new tolerance.
doctrine-14Gates measure what hardware feels: posture, margins, stripped assistsAcceptance batteries carry posture-class rows (tilt max median, per-joint L/R asymmetry, temperature) beside task rows, graded margin columns beside binary gates, chirality scored per side, at least one condition that removes the environment's free stabilization, and validated predictive scalars promoted into the gate.
Case. Three same-shaped judging errors - survival, displacement, wz-difference - all missed what the operator felt; posture metrics had the predictive power (`task-metrics-vs-posture-metrics`, `stand-gate-posture-not-survival`); binary survival saturated and hid a 60% margin gap (`constant-value-dr-overfits-margin`); v5 passed everything on the ground and failed suspended (`suspension-probe-removes-free-stabilizer`); the hip_roll (l+r) scalar predicted real drift direction and ordering and entered the battery (`hip-roll-sum-predicts-lateral-drift`); averages hide chirality (`chirality-scored-separately`); gait-quality gates are judged at speeds that demand a gait (`low-speed-commands-reward-dragging`). The recovery line added the rest of the kit: where failed episodes end, not only where they started (`end-state-confusion-matrix`); a frozen acceptance distribution with a pinned seed (`frozen-acceptance-distribution-and-pinned-seed`); video of the metric rollout itself (`video-as-acceptance-record`); and the admission that a 10 s episode cannot see a stance that fails after a minute (`episode-length-bounds-what-a-gate-sees`). The one-leg line removed a foot-spacing wall that no gate measured, and the feet met on hardware (`removed-wall-returns-on-hardware`).
Coach application. Review every battery for posture rows, margin columns, per-side scoring, and an assist-stripped condition; when operator feel and gates disagree, suspect the metric class first.
doctrine-15Fork and root selection: recoverability, maturity, frozen rewardsChoose fork roots by which candidate's deficits the coming training can pay back (precision is recoverable; lost plasticity, symmetry, and margins are not); prefer mature checkpoints as roots even when younger ones score better as products; never fine-tune through a reward change - continuation is legal only with the reward frozen and plant/DR widening one rung at a time.
Case. s1e-500 beat higher-precision candidates because its exclusive strengths were unrecoverable (`fork-root-recoverable-shortfall`); the b300 arm proved maturity is capital against adaptation shock (`root-maturity-vs-product-quality`); the B-arm scatter/half-recover/collapse signature falsified reward-change fine-tuning and drew the legal boundary for S2 continuation (`fine-tune-reward-change-falsified`).
Coach application. For root debates, build the exclusive-strengths table and ask "which side can be trained back?"; require dual-arm evidence for maturity claims; classify any proposed continuation as reward-frozen or not before approving.
doctrine-16Curricula: verified engagement, lineage counters, disease-phase gatingAutomatic curricula must prove they engage (a saturated ratchet is constant DR wearing a curriculum's name); every ramp counts lineage-cumulative progress, not per-process steps; penalties aimed at late-stage pathologies ramp in after exploration noise decays; difficulty rises on measured per-stratum success, never on schedule.
Case. The s1f ratchet capped at iter 248 and never engaged (`auto-curriculum-engagement-check`); the saturation ramp re-fired at +600 after every resume and no shipped product ever saw the penalty (`curriculum-counter-lineage-steps`); the same penalty worked once gated to the disease phase and became an untouchable mechanism (`gate-penalties-to-the-disease-phase`); record-high aggregate reward hid a fully-failing delay stratum (`aggregate-metrics-mask-subgroup-failure`); bucket share is not a gradient lever (`bucket-share-is-not-a-gradient-lever`). An assist curriculum keyed to a pooled success share was withdrawn on the strength of the categories that already worked (`curriculum-criterion-conditioned-on-lagging-category`); a pace set by per-step income moved only when that income was time-gated (`per-step-income-drives-speed-time-gate`), and the same gate had to be retired in a lineage without the disease (`time-gate-vs-wide-stance-retire-the-fix`).
Coach application. Ask every curriculum three questions: does it engage (show the internal state)? what does it count (process or lineage)? when is it present (against the pathology's phase)? Check where shipped checkpoints sit relative to every ramp.
doctrine-17Probe before training: feasibility first, hypotheses in tablesAfter two failed training attempts at a skill, stop training: demonstrate the behavior open-loop, enumerate hypotheses in a written table audited against actual configs cheapest-first, race one probe per side of the sim2real boundary for hardware-only pathologies, and use suspended tests to acquit or convict actuators before blaming authority.
Case. "在黑暗里试钥匙" - four sidewalk rungs failed until an open-loop probe separated exploration/waveform/authority in one experiment (`open-loop-probe-before-reward-tuning`); the foot-drag mystery fell to a seven-hypothesis config audit (`hypothesis-table-code-audit`); the period-doubling was resolved by racing a reward-side and a plant-side evidence line - and both paid off, one per sub-case (`period-doubling-evidence-race`); the suspended test acquitted the roll actuator in one measurement (`suspended-test-isolates-actuator-authority`). A read-only configuration probe told a wall from a slope in the recovery line's seated basin (`configuration-probe-wall-not-slope`), and the fix it pointed to - where the feet are - took prone from 0/159 to 158/159 (`prone-dead-end-is-foot-placement`); a knob that did not move its variable was recorded as no test of the idea (`dof-vel-penalty-is-not-a-pacing-knob`).
Coach application. When a skill resists training, prescribe the probe before any further reward edits; require verified target trajectories before imitation terms; keep a falsified-fixes list so closed roads stay closed (`amplitude-cut-falsified-yaw-fix`).
doctrine-18External advice is recomputed locally; values transfer as ratiosEvery external suggestion is classified adopt / already-have / modify / trap by recomputing its claim on the local reward table and probe data; numeric values transfer only as dimensionless ratios (to tracking weight, leg length, sqrt(gL), control rate); citations are verified to exist.
Case. "Start vy very small" would have destroyed sidewalk learning on this reward table - the gradient scales quadratically (`external-advice-audit-against-own-arithmetic`); swing-height targets and weights transferred correctly only through leg-length and tracking-ratio scaling (`transfer-ratios-not-absolutes`); the "6-step delay" was refused for lacking a control rate (`latency-dr-covers-measured-pipeline`); a borrowed reference's structure was FK-verified and its amplitude re-derived from the division of labor (`reference-structure-fk-amplitude-division`); retrieval agents fabricated verbatim arXiv quotes - only source-verifiable material was used; and one dismissed suggestion later proved right for a different mechanism, and was credited (`cycle-average-tracking-for-gait-quantities`). An advisor's staged state machine turned out to exist in none of the three papers it cited, and reading them changed the plan (`advisor-paraphrase-vs-paper`).
Coach application. Intercept every "paper X does Y" with the local recomputation; convert absolutes to ratios before comparison; verify quotes; revisit dismissed advice when new mechanisms appear.
doctrine-19Hardware sessions are scripted experiments, not tuning sessionsReal-robot time executes a pre-registered matrix: risk-ordered (baseline first, fragile last with a spotter), stage-gated (suspended smoke before ground), A/B sessions bracketed by a repeated reference run, operators briefed on measured zero-command and untrained-axis behavior, chirality-aware disturbance protocols, no field tuning - the only legal field changes are scripted, single-variable, and self-reversing.
Case. The S2 acceptance sheet (`risk-ordered-real-deployment`, `battery-bracketed-real-ab`, `know-zero-command-behavior`, `push-test-chirality-protocol`, `no-field-tuning-protocol`); the RAM-only torque experiment with automatic power-cycle rollback (`reversible-single-variable-field-experiments`); and the sim-veto rule - even sim's condemnations get one safeguarded hardware check when they judge the purpose-built configuration (`sim-veto-needs-real-confirmation`). The recovery line's first real run went ahead with its preconditions unmet and was stopped as dangerous (`first-real-get-up-violent-stage-one-policy`); after it: a staged hang, mat and floor protocol (`staged-hang-mat-floor-for-get-up`), a fixed power-cycle pre-flight and two-machine discipline (`power-cycle-preflight`, `two-machine-config-discipline`), a fall guard replaced rather than switched off (`fall-guard-becomes-a-state`), and logs that are part of the run (`hardware-log-is-the-attribution-input`).
Coach application. Turn every hardware request into a runbook with order, gates, brackets, briefing, and anomaly plays; refuse improvised parameter changes on the floor.
doctrine-20Close questions in writing; restart when the debt is structuralAudited questions get frozen verdicts with citable wording and an explicit reopening bar; hardware verdicts are dated by deployment-stack and calibration state and expire when those change; and when successive rungs shuffle symptoms without net progress, freeze the lineage as regression baselines, pay the structural debts, and retrain minimal - carrying laws and instruments, not weights.
Case. The chirality and COM questions were closed with frozen wording and "no reopening without new hard evidence" (`frozen-verdicts-semantic-boundaries`); v5/v6's condemnations expired with the deploy stack (`stale-verdicts-under-old-stack`); a 2-degree calibration fix moved the whole runnable envelope (`zero-offset-calibration-shifts-envelope`); plant upgrades are era boundaries with paired re-baselining (`plant-swap-invariants-vs-shifts`); and the 2026-08-05 reset froze v5-v11, fixed the latency FIFO / manifest / sampling / reward-table debts, and restarted - producing the lineage that reached hardware SOTA (`freeze-lineage-fix-structure-restart`, `minimal-reward-table-with-provenance`). The recovery line's real-robot verdicts ended up in three places that disagree, one of them an undated note in a command file (`write-hardware-verdicts-back`).
Coach application. Maintain the closed-questions ledger and quote it when symptoms recur; stamp verdicts with stack/calibration versions; when a team is three rungs into symptom-shuffling, raise the restart question explicitly with the freeze-fix-restart pattern.
doctrine-21Name the quantity in the space it lives inA goal, reward term or acceptance criterion about the feet, the base or the contact state is computed from the quantity itself - world poses, forces, per-category outcomes - never through a joint-angle, single-signal or pooled stand-in that assumes everything else sits at nominal; and every detector is validated on a behaviour known not to contain the event before it becomes a gate.
Case. The recovery line was caught three times: |ankle roll| as "flat feet" sold stance width and the real robot slid into the splits, a hip-roll criterion was confounded by 50 deg of yaw, and the joint table said 0.271 m where the feet were 0.159 m apart; task-space terms produced the first flat, wide stance (`joint-space-proxy-for-task-space-quantity`). Flight detection lied in both directions across two lines - foot height flagged 40% false flight on a walking gait, contact force alone flagged slip chatter as hops (`contact-detector-single-signal-lies`). A pooled height average described a robot that did not exist - six in ten standing, four in ten sitting (`zero-partial-credit-is-not-an-iteration-problem`) - and the walking line had learned the same lesson on yaw rate (`heading-integral-not-body-rate`).
Coach application. For every reward term and gate row, ask what physical quantity it stands for and whether it is measured directly; flag joint-space or single-signal stand-ins for task-space goals, ask for a detector validated on a negative control, and split pooled metrics by category before reading them.
doctrine-22Continuation needs a live gradient; a release is chosen by a scanContinue a converged policy only on a change that creates a live gradient, on a short budget, with every checkpoint scanned on the transfer axis; choose a release by running the full battery over a band of checkpoints and stop on signals, never by taking the last one; and when edits to the terminal phase cannot move a behaviour, roll back and retrain with the constraint present from the start, keeping the order in which the lineage acquired its mechanisms as explicit curriculum phases.
Case. A continuation with no new gradient drifted MuJoCo transfer from 100/98% to 80/28% while every Isaac gate stayed perfect, and a live-gradient continuation at the same depth kept it (`converged-continuation-is-poison`). One-leg checkpoints 100 iterations apart failed 1 and 38 of 40 cells, and late ones degraded (`checkpoint-choice-is-a-full-gate-scan`). Four in-lineage stance fixes failed because the stance was the end of the get-up path, and from scratch it grew right (`stance-decided-by-get-up-path`); fixes stacked on degraded states were rolled back by the user (`stop-stacking-roll-back-and-audit`); and the lineage's final recipe, trained from scratch in one run, sat at 0% because the order of its curriculum was part of the product (`curriculum-history-is-part-of-the-product`). The omni line's short adaptation budgets and mature roots are the same law seen from the other side (`continuation-budget-not-from-zero`, `root-maturity-vs-product-quality`).
Coach application. Before approving a continuation, ask for the new gradient, the budget and the transfer axis in the scan; before approving a release, ask for the scan; after three rungs without progress on the target, propose rolling back to the last good checkpoint and a from-scratch phase plan instead of a fourth patch.
Experience cards
44 cards tagged real-acceptance.
Bracket a real-robot A/B with a repeated reference run - battery drain is the confound
battery-bracketed-real-abOrder hardware A/B sessions as A-B-A: repeat the first condition at the end, and void the comparison if the bracket runs disagree - never let battery or venue drift ride on the second condition.
Symptom
In a two-policy teleop A/B on hardware, the second policy is measured on a lower battery voltage than the first - a systematic bias that would be read as a policy difference.
Context
C2 real A/B (checkpoint 700 vs A800, same floor, same day) was scripted as 700 -> A800 -> 700-rerun, with the explicit note that a teleop session drains the pack and the trailing policy "naturally suffers".
Change
Protocol: run the reference policy first AND last; if the two reference runs differ noticeably, declare the whole session battery/floor-polluted and void the A/B ("结论作废重来"). Also log electricity per run.
Outcome
Called out as the round's only systematic confound, closed by one extra command ("这是本轮唯一的系统性混淆源,一条命令就能堵掉").
Mechanism
Battery voltage scales available torque, and torque loss hits behavior asymmetrically (see power-scale-hurts-nonforward-axes), so drain masquerades as policy regression; a head/tail reference pair converts the unobserved drift into a measured control.
Applies when
- comparing two policies or settings on hardware in one session
- any sequential hardware evaluation where the plant drifts (battery, temperature, floor wear)
“为什么要 700 复跑:一次遥控 session 下来电池会掉压,第二枚天然吃亏。头尾各跑一次 700,若两次 700 明显不同,说明这轮 A/B 被电量污染,结论作废重来。这是本轮唯一的系统性混淆源,一条命令就能堵掉。”
train/C_LADDER_RUN.md § 3c. A-3 真机 A/B(同一段地板、同一天、电量记账) Score left and right separately - averages hide chirality breaking that mirror augmentation does not prevent
chirality-scored-separatelyReport every mirrored skill as two numbers with an explicit gap budget; never accept an average, and never assume augmentation guarantees symmetry - measure it per lineage and treat breakage as hard to reverse.
Symptom
Policies developed quantified left/right asymmetry (e.g. C2-700 turned right at 82% but left at 67% - a 15 pp gap; push tolerance 40/40 symmetric on the root vs 17/40 on a deep-trained descendant), and averaged metrics would have reported healthy midpoints.
Context
The repo had policy-level symmetry-breaking evidence strong enough to make separate scoring a battery rule: "左右必须分开打分 … 平均 vy 跟踪会把它掩盖". Notably, chirality broke and never recovered even though mirror augmentation (command-level mirror_prob 0.5) was on the whole time - augmentation reduced but did not prevent asymmetry, and once broken it stayed broken through subsequent rungs. PASS conditions therefore carried explicit symmetry budgets (left/right tracking gap <=10 pp), and sim's predicted asymmetry (700: right faster than left) was flagged for direct real-robot timing confirmation.
Change
Battery rule: every directional skill reports left and right (CW/CCW) as separate rows with a max-gap budget; mirror augmentation treated as mitigation, not proof of symmetry.
Outcome
The 700-vs-A800 asymmetry gap (15 pp vs 7 pp) became a first-class selection criterion; C4 product shipped with a measured 5 pp gap.
Mechanism
Averaging over mirrored conditions cancels antisymmetric error exactly where it matters; and symmetry lost during training is a lineage injury (like plasticity loss) that later rungs do not spontaneously heal, so it must be gated, not assumed.
Applies when
- evaluating turn/sidewalk/push-recovery or any mirrored skill
- relying on mirror/symmetry augmentation
- selecting between checkpoints with similar average scores
“左右必须分开打分(left/right lateral、CW/CCW turn 各自一行)—— 本仓已有 policy-level symmetry breaking 的量化证据,平均 vy 跟踪会把它掩盖。”
train/C_LADDER_RUN.md § 5. 固定验收矩阵 (左右分开打分) A constant-value plant rung passed every binary gate with record scores - and shipped 60% thinner posture margins that hardware exposed
constant-value-dr-overfits-marginRandomize deployment-critical axes over a narrow band spanning the measured real support - never a single value, never a fictitious tail - and report graded margin quantities (tilt margin) next to binary gates, because saturated gates rank thin-margin and thick-margin policies identically.
Symptom
s2_lag1 (trained at constant 1-frame latency) posted the strongest sim gate sheet in history (20/20 everywhere) yet was unstable on hardware, while s1e (trained across the full 0-3 frame band) was the every-run-stable SOTA at the same power.
Context
The sim autopsy (new --delay-jitter harness modeling the BusWorker's time-varying phase drift): 18 runs across constant and time-varying delays ALL survived - time variation alone does not kill - but the tilt-margin ordering reproduced hardware exactly: s1e 7.7-9.1 deg (thickest) < s2_lag1 10.7-15.0 < s1c 16.2-18.2. Attribution: constant-value training permits precise specialization to that one value; s1e's band diversity forced cross-value robustness - "恒定 1 帧训练 vs s1e 的 0~3 帧全带——分布多样性逼出跨值鲁棒,恒定值允许精确 特化" - so the constant-rung policy's margins were ~60% thinner, fine in sim's clean world, pushed over the line by real-world disturbances. Tool lesson booked: "存活门二值饱和后掩盖裕度差" - binary survival gates saturate and hide margin differences; graded margin columns (tilt-max) belong in the report. The synthesis with the opposite failure (wide tails cause drag-glide): the proposed resolution was a NARROW uniform band (0.02, 0.04) covering exactly the real 1-2 ticks - diversity inside the measured support, no tail, no single point. s1e's root selection later leaned on the same property: its full-band latency training "预装" the delay rungs and delivered "全工况稳定裕度" that survived power derating.
Change
DR-on-an-axis design refined to a three-way distinction: no wide fictitious tails (drag), no single constant values (thin margins), but a narrow band spanning the measured real support; acceptance reports gained graded margin columns alongside binary gates.
Outcome
The tilt-margin column entered the standard report; the s1e root (band-trained) carried the C ladder while the constant-value branch was archived with its three contributions credited.
Mechanism
Robustness margins are shaped by the diversity of the training distribution, not just its support: a point-mass distribution lets the optimizer trade margin for on-point performance, while a band forces solutions that keep margin across the band - and binary survival metrics cannot see the difference until the margin is spent on hardware.
Conflicts
The narrow-band (0.02,0.04) resolution was a pending recommendation ("裁决建议(待用户)") at the time of writing; the lineage instead moved root to s1e whose full-band training predated the staged ladder - the deterministic-staging card and this card record the two failure modes the final design must avoid simultaneously.
Applies when
- a rung trained at a fixed plant value aces sim but wobbles on hardware
- binary acceptance gates are all saturated across candidates
- choosing between constant, banded, and wide DR on one axis
“18 跑全活,时变性单独不足以击杀;但 tilt_max 裕度排序完整复现真机:s1e 7.7~9.1°(最厚)< s2_lag1 10.7~15.0 … 恒定 1 帧训练 vs s1e 的 0~3 帧全带——分布多样性逼出跨值鲁棒,恒定值允许精确特化 … 存活门二值饱和后掩盖裕度差(s2_lag1 sim 门 20/20 史上最强却真机不稳)”
train/README.md § s2_lag1 真机不稳 × s1e 稳的 sim 对拍(2026-08-07,时变延迟实验) Slowing the gait clock at deployment is out-of-distribution and backfires - lower the commanded speed instead, or train the knob
cycle-time-override-is-oodAny deployment override must correspond to a dimension the policy was trained to handle; to make a parameter field-adjustable, randomize it in training and observe it - otherwise use the levers inside the trained envelope (commands) and leave the knob alone.
Symptom
Real-robot feedback "walks very fast and unstable" suggested slowing the gait; a deploy-side --cycle-time override existed, making "just slow the clock" a one-flag temptation.
Context
A sim sweep of the override on walk_v6 @cmd 0.3 showed monotone degradation away from the trained 0.40 s cycle: at 0.50 s tilt jumped 7.9 -> 13.2 deg and landing force 1.52x -> 2.24x; at 0.80 s (half speed) clearance collapsed to 3 mm - dragging again - with 20 deg tilt. Meanwhile the legitimate lever, lowering the commanded speed with the clock untouched, improved everything monotonically: cmd 0.1 gave 104% tracking, 6.7 deg tilt, minimum slip - the most stable operating point. The file distinguishes the two "slows" explicitly: lower command = smaller steps at the same 2.5 Hz rhythm; a slower rhythm itself requires retraining - randomize cycle_time (e.g. 0.40-0.65 s) during training and expose it as an observation, and only then does --cycle-time become a field-adjustable knob.
Change
Deployment guidance: never ship a cycle-time override the policy was not trained under; respond to "too fast/unstable" with lower commands; schedule clock variability as a training-time (contract-level) change if a field knob is wanted.
Outcome
The sweep quantified the trap before hardware paid for it (dragging and 2.2x landing force at slowed clocks); cmd 0.1 documented as the stable demo point.
Mechanism
The policy is a function fitted around the training distribution; a deploy-side override moves an input (phase rate) to values never seen, so behavior degrades unpredictably - the knob LOOKS like a capability because it exists in the code, but capability lives in the training distribution, not the interface.
Applies when
- a deploy tool exposes overrides (clock, scale, gains) beyond the training distribution
- hardware feels "too fast/aggressive" and a quick knob exists
- deciding between a deploy-side tweak and a retrain
“0.80s | 1.25Hz | 0.165 | 3mm(拖地) | 20.0° … 慢一半直接崩 … 策略按 0.40 训练, 别的周期属分布外。… 降指令速度才是有效杠杆 … cmd 0.1 是最稳的工作点。… 要节奏本身变慢必须重训 —— 训练期把 cycle_time 随机化(如 0.40~0.65s)并作为观测的一维, 部署时 --cycle-time 就成了现场可调的旋钮。”
train/WALK_DIAGNOSIS.md § 2026-08-01 追加: 调慢步态时钟(--cycle-time)在仿真里是反效果 An outer heading P-loop at deploy cut drift 10x because its output stays inside the trained command band - then training was aligned to it
deploy-heading-loop-and-align-trainingFix drift-class problems first with an outer loop whose output provably stays inside the trained command band; when adopting it permanently, align the training command generator to the deployment's actual command mixture (feedback-driven AND constant), matching law, gain, and clip exactly.
Symptom
Persistent heading drift on straight-line walking (v6 net yaw 60.3 deg over 15 s) that reward-side fixes had only partially tamed.
Context
The deploy stack added --heading: an external P loop wz = clip(0.5 * wrap_to_pi(theta0 - theta), +/-0.6), recomputed each frame and fed into the policy's ordinary wz command slot. Measured: net yaw walk_v6 60.3 -> 5.8 deg, walk_v5 17.4 -> 4.2 deg. A run-level audit later corrected the mechanism story: training had heading_command=False since v1 - the policy had NEVER seen heading-error feedback, so the loop works purely because its output lands inside the trained command distribution wz ~ U(+/-0.6): "收益真实,当时的机理解释写错了" (the benefit is real; the mechanism explanation had been wrong). v8 then closed the loop properly: training-side heading command enabled with rel_heading_envs=0.5 - half the envs get heading-error-driven wz, half get explicit constant wz, because deployment feeds wz BOTH ways (straight-line = heading feedback, turning = constant command) and rel=1.0 would have made constant-wz turning out-of-distribution. The law, gain, and clip were aligned item-by-item between trainer and deploy tool.
Change
Deploy-side outer loop first (no retrain needed); then v8-D enabled the matching training-side heading command at rel=0.5 with identical gain (0.5) and clip (+/-0.6), contract unchanged (wz slot carries the computed value).
Outcome
Drift handled at deploy (5.8 deg) generations before training caught up; the alignment removed the residual train/deploy distribution mismatch, with the accepted cost booked (open-loop straight walking becomes more OOD for heading-envs - irrelevant since acceptance and deployment always run the loop).
Mechanism
A learned velocity-tracking policy is a valid inner loop for any outer controller whose commands stay within the trained command distribution - the policy needs no knowledge of the outer objective. Full alignment then requires training on the same mixture of command sources the deployment actually uses, in the observed proportions.
Applies when
- heading/position drift on a velocity-tracking policy
- designing outer loops over learned locomotion controllers
- training command distribution differs from how deployment feeds commands
“审计更正(2026-08-02,run 级 env.yaml):训练侧自 v1 复盘起就是 heading_command=False … 策略从未见过航向误差反馈。--heading 是评估/部署侧外加的航向 P 环(wz=clip(0.5·err,±0.6), 落在训练分布 wz~U(±0.6) 内)。实测净偏航 walk_v6 60.3° → 5.8° … 收益真实,当时的机理解释写错了”
train/WALK_V7_SPEC.md § 0. 本轮之前已经改掉 (航向闭环, 含审计更正) When hardware underperforms, audit deployment knobs before prescribing retraining
deploy-knob-attribution-before-retrainingBefore any "retrain it" decision, reproduce the symptom in sim under the exact deployment configuration; if the symptom follows the deployment knob rather than the checkpoint, fix the knob or randomize it in training - never top-up-train the skill.
Symptom
Real-robot feedback after the C4 deployment - "turning is weak" - with two retraining options on the table: top up turn training, or restart from the s1e root.
Context
The sim account showed the policy turned well (75-81% at pw1.0); the robot was deployed at power-scale 0.8. The 3-6 pp difference between C2 and C4 policies at the same power was noise; the 40-50 pp difference between power levels was the entire effect. Both proposed retraining paths would have burned budget on a non-existent training gap, and restarting from s1e would additionally have discarded the sidewalk skill that took four rungs and a coordinate-bug hunt to obtain.
Change
Decision: retrain nothing. (1) Try pw1.0 on hardware first - sim says net gain; (2) only if 1.0 is unacceptable (heat/feel), the correct training fix is power/torque randomization in the S2 plant line (one variable, fixes turn and backward together) - not skill top-up; (3) restart-from-root explicitly ranked worst.
Outcome
The "weakness" was fully explained by the deployment knob; the sim/real signatures matched the earlier power-derating law verbatim ("与 C2 时代 power 衰减主要伤非前进轴 逐字吻合").
Mechanism
The policy's competence is defined under its training plant; deployment knobs (power scale, teleop mapping, command bands) silently define a different plant. Attributing a deploy-plant effect to a training gap produces exactly the wrong fix - more training on the wrong variable.
Applies when
- real robot underperforms a skill that sim says is fine
- proposals on the table include retraining or re-rooting
- deployment uses any override the trainer never saw (power scale, remapped commands, different control rate)
“正确的训练修法不是补训转向,而是训练时加 power/力矩随机化让策略在 0.8 下自己补偿 —— 单变量,属 S2 plant 线,一次同时修好转向与后退;从 s1e 重训是最差选项:丢掉四轮 + 一个指标 bug 才换来的侧走,而 C2 的转向本来就没问题。”
train/C_LADDER_RUN.md § 3p. 三 处置顺序(回答「补训转向 还是 回 s1e 重训」:都不该) Tightening the bridge's rate limiter under an unchanged policy cut torque peaks 30-50% and made other things worse - the policy cannot see the limiter, keeps commanding and winds up; a deploy-side limiter is a safety net, not a cure
deploy-rate-limiter-windupA rate or torque limiter added at deployment lowers peaks but the policy still commands as if unconstrained (saturation, windup, new contacts); use it as a safety net mirrored in evaluation, and put the constraint where the policy can learn around it.
Symptom
After the violent first real-robot get-up, the cheapest candidate fix was to tighten the bridge's slew (rate) limit for the recovery policy without retraining.
Context
Probe on R3.1 in MuJoCo (5 categories x 3 seeds, mu 1.0), monkeypatching the limiter with no repository change: TIGHT = RS06 4.0 / RS02 3.0 / RS00 2.0 rad/s (about 0.08/0.06/0.04 rad per policy step) against the current vel_limit setting.
Change
The probe decided the role of the limiter rather than a deployment.
Outcome
Success 14/15 -> 12/15; get-up median 2.35 -> 3.53 s (max 9.30); torque demand peak median hip_pitch 164% -> 111%, knee 166% -> 86%; action saturation still 100%; leg-leg contact 558 -> 860 frames. The limiter was kept only as a real-robot safety net (mirrored into sim2sim evaluation); the cure moved into training - where the next lesson was that a limiter anchored on the last command is itself an integrator (slew-anchor-is-an-integrator).
Mechanism
A policy that never trained with the limiter keeps issuing the targets it learned; the limiter clips them, the target window runs ahead (windup), and the robot follows a trajectory the policy never evaluated.
Applies when
- a trained policy is too violent on hardware and a quick deploy-side fix is tempting
- adding slew, torque or velocity limits in a bridge or firmware
- evaluation and deployment use different limiter settings
“判读:**链路侧收紧立等可取地把 τ 峰值砍 30~50%,但成功率掉、饱和率仍 100%、 腿-腿接触反升** —— 策略感知不到限速器,目标窗口继续狂奔。⇒ 收紧 slew 只配当 **真机侧安全网**(必须同步进 sim2sim 口径,基础设施现成),**不配当治法; 治法必须进训练**。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §26 探针:收紧桥层 slew,r3_1 不重训直接测 A 10 s acceptance episode left 6-7 s of standing to observe - a narrow stance held for that window and split on hardware; a gate cannot see instability slower than its own horizon
episode-length-bounds-what-a-gate-seesSize the standing phase of an acceptance episode, and its disturbances and floor friction, to what deployment will impose; a pass on a short static window certifies only that window.
Symptom
v2_6 passed every simulation gate (success 99.6%, re-falls 0-1%) and then, on the real robot, stood up and slid into the splits several times; prone starts stood and then fell backwards.
Context
Acceptance ran 10 s episodes; a ~1-2 s get-up left roughly 6-7 s of static standing on a nominal floor with no disturbance. The narrow stance's lateral margin and the straight-knee stance's lack of any flex buffer are both failure modes that need time, disturbance or lower friction to show.
Change
The gap was booked as a known blind spot of the gate ("long-duration standing stability") alongside the task-space stance criterion; later rungs added MuJoCo friction sweeps at mu 0.4 to every checkpoint scan.
Outcome
The spec through §50 records the blind spot but no longer standing window or disturbance row in the recovery acceptance itself.
Mechanism
An acceptance episode observes only the dynamics that unfold within its horizon under its conditions; slow drifts and disturbance-triggered failures are outside it by construction.
Applies when
- a policy passes sim gates and fails on hardware after a delay
- acceptance episodes are short relative to deployment use
- stability is judged without pushes or friction variation
“**sim 门为什么没逮住**:10 s episode 起身后只站 ~6-7 s,静态窗口内窄站距 撑得住;真机站立时长/扰动谱在门口径之外 —— 长时站立稳定性记为口径缺口。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §43 判读:sim 门为什么没逮住 A walking policy's tilt cutoff is a legal state for a recovery policy - the default 45 deg fall guard had to be raised for recovery tests and is disabled once the switch owns falls, so the abort chain becomes the recovery timeout, the operator's cut, and the firmware torque limits
fall-guard-becomes-a-stateWhen a new skill makes a safety cutoff's trigger a legal state, replace the cutoff with a bound of the skill's own (a timeout ending in a safe stop) instead of just switching it off; keep the operator's cut and the firmware limits as independent layers, and write every flag change into the run sheet.
Symptom
deploy_policy's default protection stops the robot beyond 45 deg of tilt. A recovery policy starts lying at roughly 90-97 deg, so under the default it is refused on the spot - a flag the first hanging checklist forgot.
Context
The layers in the sources: deploy_policy's tilt cutoff (default 45 deg, a line in the safety chain); for standalone recovery tests the cutoff was raised (110 deg in the spec's A/B sheet; 181 deg, effectively off, in some runbook commands); with --recovery-policy the cutoff is disabled because a fall is now a state, not an exception, and RECOVERY lasting over 15 s ends in a safe stop (the runbook calls it the line where the spotter steps in). Independent of the policy: firmware torque limits checked at start (12/17/11 N*m, set_torque --check), the operator cutting enable at any kicking or oscillation, and in the one-leg teleop a space-bar stop that puts the foot down.
Change
The flag was added to the run sheets, and the FSM replaced the removed cutoff with its own bound (the timeout).
Outcome
The spec records the flag omission and its fix; it does not record the FSM's timeout being exercised on hardware.
Mechanism
A safety cutoff encodes one policy's notion of "abnormal"; a new skill whose normal operation lies beyond it either cannot run or runs with the cutoff off, and only a replacement bound keeps the chain closed.
Applies when
- deploying recovery, fall-damage or acrobatic skills behind existing safety checks
- a run sheet disables a protection flag
- listing the abort chain for a hardware session
“--max-tilt-deg(默认 45°,安全链第 13 行写的那个)。recovery 的合法状态覆盖整个倾角域,把它抬到 181 = 实效关闭 … RECOVERY 超时 15s 会自动安全停(看护介入线)”
RL系统/FOLLOW THIS copy 2.md § FSM 吊挂首测 ② 落地测 / #### Recovery Policy (operator runbook, undated) The first real-robot get-up was "very violent, kicking on the floor, dangerous" - a sim-perfect policy with no reason to be slow, unbounded absolute targets, no domain randomization and a rate limiter that filtered nothing; the task was restated as "safe, slow, transferable"
first-real-get-up-violent-stage-one-policyDo not put a get-up policy on hardware until its action is bounded (hard bound or state-anchored targets), smoothed, randomized and tested at the real pipeline's latency, and say explicitly that the task is "safe, slow and transferable" - a simulation-perfect policy optimizes only "gets up".
Symptom
On 2026-08-09 the user ran a V0-lineage recovery policy on the real robot and stopped it: very violent, kicking on the floor, dangerous. The planned next rung (a heavier torque_headroom) was never started.
Context
The spec had pre-registered that R0/R1 products stay in simulation and that the real-robot precondition was the R3 smoothing rungs plus a bridge-slew check plus a hanging protocol; the robustness (DR) rungs had not run. In simulation the policy passed 100% with a get-up of about a second. Which ONNX, which gain profile and whether a torque/joint log existed were left "to be recorded later" and never were.
Change
The V0 ladder was stopped at its best product (R3.1, sim only) and a re-rooting proposal was put to the user. The spec's four-layer account: style (the reward pays for standing early and nothing pays for slowness - HumanUP's "Stage I" get-up, "fast but unsafe ... infeasible for real-world deployment"); impact (full-range absolute targets with no hard bound, raw |a| up to 4.77, action saturation 100%, a single-step change of 0.306 saturating hip_pitch); transfer (zero DR, friction pinned at 1.0, the learned leg bracing); link (the bridge's RL slew equals vel_limit, 0.2-0.66 rad per step, while the real pipeline has 1-2 steps of time-varying latency and acceptance ran at delay 0).
Outcome
The line was re-rooted twice (training-side rate limit, then the beta-anchored action space) and gained a hang protocol before the next real attempt; on 08-11 a beta-anchored policy produced the line's first real get-up.
Mechanism
A task reward that pays for standing early selects the fastest feasible get-up; with absolute full-range targets every large target jump is a torque impulse bounded only by the clip; zero DR and braced-leg solutions do not transfer; and a limiter set at the velocity limit does nothing at 50 Hz.
Conflicts
The four layers are the spec's reconstruction from simulation probes and the literature; the real run's policy file, gain profile and log were never recorded, so no layer was confirmed against hardware data.
Applies when
- a first hardware trial of a high-effort skill is being scheduled
- sim success is high but the policy saturates actions or torques
- pre-registered hardware preconditions are not all met
“用户真机反馈:**非常猛、地上乱踢、危险**,叫停(R3.3 torque_headroom 加档已选型 weight −0.5→−1.5,未启动)。真机细节(哪个 onnx、什么档、有无 τ/q log)**待补记** … 任务从"能起来"变成 **"安全、慢、可迁移"** … **链路层**:桥层 slew RL 档 = vel_limit(10/20/33 rad/s ≈ 每拍 0.2~0.66 rad), 对 recovery 形同虚设;真机 1~2 拍时变延迟,验收默认 delay 0。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §26 真机叫停与换根判决(2026-08-09) Removing a hand trim re-exposed the plant offset it had been silently compensating - and a slope scan told bias from sensitivity
hand-trims-hide-plant-offsetsTreat hand-tuned trims as undocumented plant measurements: before deleting one, find what it compensates and re-house that knowledge in the model or the reward budget; diagnose posture errors with a sensitivity sweep to distinguish constant bias from gain problems.
Symptom
After switching from the old hand-trimmed default to the clean geometric zero, the retrained stand policy's only regression was torso lean: 1.8 deg -> 4.1 deg backward.
Context
The old default's ankle-pitch trim (-0.0489/+0.0628) had been pre-compensating a fore-aft COM mismatch; removing the trim removed the hidden compensation, and the posture reward alone was too weak to win it back. A COM sensitivity scan settled what kind of problem this was: sweeping base COM offset -50 to +50 mm gave nearly identical slopes for old and new policies (~0.026 deg/mm) - "不是质心敏感度问题, 是恒定偏置" (not a sensitivity problem, a constant bias). Fix landed in stand_v1b: posture corrected to +0.24 deg while keeping symmetry (<=0.1 deg) and low effort (0.259), disturbance rejection better than both predecessors. Model credibility was checked the honest way: v0's sim prediction at the real COM position (-22 mm) was -2.31 deg lean vs real measured 2.2-3.1 deg - "预测精准命中" - which is what licensed trusting v1b's -0.52 deg prediction. (Side flag from the same file: a sign convention had been documented wrongly in early comments - gravity_base[0] > 0 is forward lean.)
Change
Trims retired in favor of explicit modeling: symmetric geometric default plus a posture-reward budget sized to carry the real COM offset; the offset itself known (real COM ~22 mm behind model).
Outcome
stand_v1b passed acceptance as the standing lineage's final version; the walk-line requirement "加大躯干姿态惩罚权重" was upgraded from suggestion to mandatory, since walking amplifies what standing tolerates (real walk_v1 hit 26 deg lean vs sim 7.4).
Mechanism
Hand trims are plant knowledge stored in the wrong place - invisible, asymmetric, and stale after recalibration; removing them re-exposes the raw plant error. A sensitivity sweep separates the two possible diagnoses (slope change = control problem; parallel offset = constant plant bias), each with a different fix.
Applies when
- cleaning up hand-tuned offsets/trims in defaults or calibration
- a posture bias appears after a default or calibration change
- deciding whether a lean is a COM-sensitivity or constant-offset issue
“两者斜率几乎相同(≈0.026°/mm),v1 只是整体多后仰约 2.4° —— 不是质心敏感度问题,是恒定偏置。成因:旧 default 的踝俯仰 trim(−0.0489/+0.0628)本就预补偿了前后质心偏差,换成零位 default 后这份补偿没了 … v0 在真机质心处(−22 mm)的 sim 预测为 −2.31° 后仰,真机实测 2.2~3.1° 后仰 —— 预测精准命中。”
train/RETRAIN_v2.md § 4b. stand_v1 独立验证结果 / 4c. stand_v1b 验收结果 A hardware run without its log is an anecdote - the first real get-up's policy, gain profile and log were never recorded, two CSVs stayed "to be reported", and runbook commands wrote different policies' logs under one copied filename
hardware-log-is-the-attribution-inputMake the log part of the run: name it from the policy and conditions automatically (never by hand-copied filenames), record the policy digest and gain profile inside it, include what the open questions need (torque, joint positions and targets), and treat a session without a collected log as incomplete.
Symptom
The recovery line's oldest open question - whether Isaac or MuJoCo reads torque demand correctly - was waiting on real-robot logs that never arrived, and the verdicts that did arrive could not be tied to files.
Context
deploy_policy writes a CSV per run (--log); the runbook's own analysis snippet reads its joint-position, target and action columns (q_, tgt_, act_), and the recovery hanging checklist asks for torque and joint logs for the whole run, to be compared with simulation. The first real get-up (08-09): policy, gain profile and log "to be recorded later". The first real A/B (08-11): v2_5b's result and both policies' CSVs "to be reported". In the runbook's walking commands, three runs of two different c4 policies log to real_s1e_pw08_teleop_0808.csv, and s1e and s2e_fric runs log to real_c2_700_pw08_teleop_0808.csv - filenames copied from other commands.
Change
None recorded; the spec kept listing the open-loop comparison as waiting for real logs.
Outcome
No real-robot log appears in the recovery spec through §50, so the simulator disagreement stayed unresolved and hardware verdicts stayed unattached to data.
Mechanism
Attribution needs the run's identity (policy digest, profile, conditions) and its signals in one artifact; a filename copied from another command mislabels the file, and a log not collected at the session is rarely collected later.
Applies when
- planning a hardware session whose result should settle a sim question
- log filenames are typed or pasted by hand
- hardware feedback arrives as prose without files
“python tools/deploy_policy.py --policy train/policies/omni_c4_ff800_pj.onnx … --log train/real_logs/real_s1e_pw08_teleop_0808.csv … q,t,a=d[:,c("q_")],d[:,c("tgt_")],d[:,c("act_")]”
RL系统/FOLLOW THIS copy 2.md § Walk 遥控 / S2 / csv 分析片段 (operator runbook, undated) The hip_roll (l+r) asymmetry scalar predicted real-robot lateral drift - promote validated sim scalars into the gate
hip-roll-sum-predicts-lateral-driftHunt for cheap sim scalars that predict real-robot behaviors, validate them on direction AND ordering across multiple policies, then promote them into the acceptance battery; treat later violations as debt to justify in writing, not noise to ignore.
Symptom
A persistent hip_roll left/right asymmetry row in the sim2sim symmetry table had been dismissed as "calibration or mechanical asymmetry" noise; meanwhile real deployments drifted sideways by policy-dependent amounts.
Context
Forward-kinematics analysis reframed the scalar: both hip_rolls move the feet in +y for positive angle, so a same-signed (l+r) sum IS a lateral translation mode - the scalar is a direct lateral-drift bias estimate. Checked against real deployments: s1e (l+r = -0.0178, smallest magnitude) was the steadiest with least drift; 700 (+0.0253) drifted mildly left; A800 (+0.0267) drifted clearly left with the largest tilt 12.9 deg. Direction correct 3/3, ordering correct 3/3 (the log's heading calls it "四枚四中", four-for-four).
Change
The scalar was promoted into the acceptance battery as a posture-class criterion alongside tilt-max median: "hip_roll 左右不对称 |l+r| 不得比父代大" - doubling as a heat proxy (error ~ torque ~ heating).
Outcome
Used at every later gate; when the C4 product exceeded it by +0.005 rad (~+0.3 deg vs parent), the criterion was not silently waived - it was booked as explicit debt with a mechanism argument (the increment is task-required, far smaller than the sidewalk amplitude +/-2.2 deg) plus a related account (stand saturation 32.4% -> 37.2%).
Mechanism
A policy's static joint-angle bias in a translation-producing mode integrates into real-world drift; sim can measure that bias precisely and cheaply. A sim scalar earns gate status exactly when its predictions are validated against hardware in both direction and ordering - and a validated gate may only be exceeded with a written mechanism-level justification, never silently.
Conflicts
The log's heading says "四枚四中" (4/4) but the evidence table lists three policies and the text says "方向 3/3、排序 3/3"; the fourth instance is not shown in this file.
Applies when
- a real robot drifts or leans in a policy-dependent way
- deciding which sim measurements deserve gate status
- a validated gate criterion is marginally exceeded by a new product
“s1e | −0.0178(绝对值最小)| 微右、最不飘 | 三者中最稳、飘最小 ✓ … A800 | +0.0267 | 左、最飘 | 明显左飘、倾角最大 12.9° ✓ 方向 3/3、排序 3/3。 → 正式纳入验收表(与「倾角 max 中位」并列为姿态类判据)。”
train/C_LADDER_RUN.md § 3e. 顺带:hip_roll 左右不对称 (l+r) 就是横移偏置 —— 四枚四中 IMU observation age cut 52-68 ms to ~4 ms by moving AHRS onto the MCU - as a single variable
imu-age-move-fusion-downstreamAudit observation age end-to-end and move time-critical fusion as close to the sensor as possible - and when you fix a latency, change only that one variable so the gain is attributable.
Symptom
IMU-derived observations reaching the policy were 52-68 ms old because attitude fusion ran in Python on the loaded host computer - stale attitude is a direct feedback-loop delay the policy was not trained with.
Context
The fix was scoped deliberately narrowly: move the AHRS computation from Python to the STM32 H7 (MC02). CAN topology explicitly unchanged, so the change is a clean single variable.
Change
AHRS fusion relocated Python -> H7. Before/after - IMU age: 52-68 ms -> ~4 ms; CAN timing: unchanged; Python load: high -> ~0.
Outcome
IMU age reduced by an order of magnitude with no confound; host CPU headroom recovered ("把计算单元搬在stm32上, 这样imu有剩余").
Mechanism
Sensor age is pipeline latency, not sensor quality: fusing on the MCU next to the sensor removes host scheduling jitter and interpreter overhead from the critical path. Keeping the bus topology fixed makes the improvement attributable to the relocation alone.
Applies when
- measured sensor-to-policy age far exceeds sensor sample period
- attitude fusion or filtering runs on a loaded host CPU in an interpreted runtime
- planning infrastructure changes during a sim2real campaign
“AHRS 搬到 H7——这个不改 CAN 拓扑,只是把一段计算从 Python 挪到 MC02,单变量:IMU age 52–68 ms → ~4 ms / CAN 时序 不变 / Python 负载 高 → ≈0”
Experience.md § AHRS 搬到 H7 (lines 28-35) Three times a joint-angle stand-in for a foot-level quantity was gamed or lied - the absolute ankle roll sold stance width to buy flat feet, a hip-roll criterion was confounded by 50 deg of yaw, and the joint table said 0.271 m where the feet were 0.159 m apart
joint-space-proxy-for-task-space-quantityExpress foot-level (task-space) goals and acceptance criteria in task space - link attitude and lateral spacing from world poses - never through joint angles that assume other joints are at zero, and measure the task-space value before trusting a joint-space estimate of it.
Symptom
The line's first real-robot get-up (v2_6, 2026-08-11) was "fairly stable", but after standing the feet were too close and the robot slid into the splits and fell several times; later reports added that it also got up through a split posture.
Context
(1) flat_feet penalized sum |q_ankle_roll|, but a flat foot is ankle roll compensating hip roll; the proxy taxed the compensated wide solution, and the untaxed combination was hips straight plus ankles at zero - flat and narrow. On hardware the lateral support shrank to hip width plus centimetres, lateral balance rested on 11 N*m ankle motors, and the feet slid apart. (2) The next rung's acceptance criterion "hip roll >= 20 deg" assumed zero hip yaw; at 50 deg of yaw the lateral contribution is x cos 50 ~ 0.64 - the same substitution again, inside a criterion. (3) A new task-space diagnostic reading the foot links' world poses measured v2_6c's stance at 0.159 m where the kinematic audit from joint angles had said 0.271 m (0.271 x cos 47 ~ 0.17).
Change
Rule written into the spec: task-space quantities are never expressed through joint-space proxies. V3.1's stance terms were all task-space: flat_feet_task from the foot links' world orientation, lateral foot spacing in metres, stand_pose stripped of both roll joints.
Outcome
From scratch with task-space terms (V3.1 P1c): lateral stance 0.355 m, foot residual tilt median 0 deg / P75 2.0 deg, all six criteria passing, mu 1.0-0.4 all 100%.
Mechanism
A joint proxy bundles the goal with everything else those joints do; the optimizer finds the combination the proxy does not tax, and a joint-based criterion silently assumes the other joints sit at their nominal.
Applies when
- rewarding flat feet, stance width, foot placement or end-effector pose
- an acceptance criterion is written in joint angles for a geometric goal
- joints with large yaw or coupled axes are involved
“**病根 = 关节空间代理**:`flat_feet` 罚 Σ|q_ankle_roll|(§41 取的简易口径)。 "脚掌平"的运动学正解是 **踝滚补偿髋滚**(q_ankle_roll ≈ −q_hip_roll) … 代理把"脚平"和"站距"绑死在一起卖了。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §43 真机首试入账(2026-08-11)判读:flat_feet 的代理口径错误 Brief the operator on the lineage's measured zero-command and untrained-axis behavior before handing over the joystick
know-zero-command-behaviorBefore any teleop/demo, measure and write down the policy's zero-command behavior and per-axis competence, label untrained axes explicitly as not-bugs, and set the floor/procedure to accommodate the known drift.
Symptom
A teleop session was about to start on a policy that does not stand still at zero command and has never been trained on lateral commands - behaviors an unbriefed operator would report as bugs or emergencies.
Context
Three measured facts were written into the teleop instructions ("都有 实测依据, 不是猜"): (1) A/D (lateral) keys will get essentially no response - probe-measured sidewalk tracking ~3%, an untrained axis: "这正是 C4 要解决的事, 不是 bug"; (2) no keypress = cmd 0, and this lineage does not stand still at zero command - a three-generation lineage property: paces in place, drifts right ~5 cm/s, net rotation -30 deg/20 s; sim survival is 20/20 (it will not fall) but it walks away slowly, so leave floor margin especially on the right; (3) S (backward) WILL respond - probe-measured 20/20 survival, 67% tracking untrained, which is also why this root was chosen for the C ladder. Plus a keybinding dry-run while suspended before touching down.
Change
Operator briefing became part of the deployment artifact: expected response per key, expected idle behavior with magnitudes and directions, and the distinction between untrained (expected, not a bug) and abnormal.
Outcome
The session proceeded with correct interpretations available in advance; the known zero-command wander was handled by floor margin and start-with-command procedure rather than misdiagnosed on the spot.
Mechanism
A learned policy's off-nominal behaviors (idle drift, untrained axes) are lineage properties, stable and measurable in sim beforehand; operator surprise converts known properties into false incident reports and unsafe reactions. A briefing transfers the measured behavior model to the person holding the controller.
Applies when
- handing a learned policy to an operator or demo audience
- the policy idles in a non-stationary way at zero command
- some command axes are untrained in the current lineage
“A/D 基本不会有反应 —— s1e 从未训过非零 vy, 选根探针实测侧走跟踪率 ~3% … 这正是 C4 要解决的事, 不是 bug。… 不按键 = cmd 0, 而 s1e 在零指令下不站定 —— 血统属性, 三代实录: 原地踏步 + 右漂 ~5 cm/s + 净旋 −30°/20s。”
train/REAL_RUN_S2.md § 附: WSAD 遥控 上机前必须知道的三条 When a contract default changes, old policies must run under a pinned legacy profile - a silent clock swap is out-of-distribution on hardware
legacy-profile-pinningTreat every trained policy as bound to the contract values of its training era: version the deployment profiles, pin old policies to their era's profile in every command, and never let a changed default silently apply to an old artifact.
Symptom
The walk profile's gait clock moved from 0.40 s to 0.50 s for new training, but versions v5-v9 were all trained at 0.40 s - running them under the updated default would silently feed a 25% slower phase clock to policies that never saw one.
Context
The re-test runbook hard-codes --policy-profile legacy_walk_040 into every command for the old versions, with the warning not to omit the flag: the mismatch is invisible (no error, no crash) but puts the policy out of distribution on hardware, where the same file had already documented that off-clock operation collapses gait quality.
Change
Deployment profiles versioned per training era; historical policies permanently associated with their era's profile; runbooks write the profile flag explicitly rather than relying on defaults.
Outcome
Old policies stayed runnable and comparable after the contract moved on; the silent-mismatch failure mode was closed by convention.
Mechanism
Changing a shared default rebinds every old artifact to a contract it was not trained under; unlike a schema break, a value change produces no error - only degraded, unexplainable behavior. Version-pinned profiles make the binding explicit and permanent.
Applies when
- changing any default in the deployment contract (clock, scales, gains) while old policies remain in use
- writing runbooks that mix policy generations
- a re-tested old policy behaves worse than its era's records
“2026-08-02 起 walk profile 的时钟改为 0.50(WALK_V10_SPEC §3)。v5~v9 全是 0.40 训的,本文件所有命令已改带 --policy-profile legacy_walk_040 ——不要省掉这个 flag,否则是拿慢 25% 的相位时钟静默喂旧策略(分布外,真机危险)。”
train/REAL_SWEEP_V5_V8.md § 1. 预检 ⚠️ 时钟改为 0.50 Ungated phase shaping made standing 42x more expensive than stepping - and the stepping was cooking the hip motors
moving-gate-42x-stand-taxGate every phase/clock-driven shaping term on the command that justifies motion, price the cmd=0 case explicitly during design - and when a reward flaw is sim-only, book it with trigger conditions instead of operating immediately on a working lineage.
Symptom
At cmd = 0 the sim policy never stood still - it stepped in place and crept 0.98 m per 20 s; on the real robot the same lineage's stepping made hip_roll motors run 20 degC hotter than every other joint (43-48 degC vs 25-28).
Context
The arithmetic closed it: the three phase-shaping terms (joint_pos_ref 1.6, feet_contact_number 1.2, feet_clearance_swing 1.6) are driven by the gait clock with NO command gating, so standing at cmd=0 forfeits 3.32/step of shaping while honest standing earns only 0.078 of tracking - stepping wins 42x. The heat chain: perpetual stepping = perpetual single support = one hip_roll stalled at ~4.3 N*m (25% of torque limit) carrying the torso's frontal-plane moment - two hip_rolls = 90% of whole-machine steady-state I2R; measured stand-vs-step comparison: total heat -71% when actually standing. The suspended test acquitted the actuator (0.21 rad sag -> 0.0008 rad in air) and mechanics vetoed the easy fix ("降 kp 救不了热" - equilibrium torque equals the external load regardless of kp). The fix (moving_gate: hard-gate the three shaping terms on |cmd| > eps) was designed - then DEFERRED by the user because the real robot at the time stood fine: "真机不表现该问题, 为真机不存在的病改奖励表不划算", with written trigger conditions (C-ladder stand row persistently failing, or real robot starting to step/drift at cmd=0) and the known hazard tag (this is exactly the reward-change class that triggers the B-arm signature). When the real robot later DID step and cook, the booked trigger fired and moving_gate moved from debt to to-do with its benefit re-priced: "停止空烧 hip_roll,稳态发热降 ~71%".
Change
moving_gate designed with the gate_by_cmd convention; deferral, triggers, and expected heat recovery all pre-registered instead of patching the reward for a then-sim-only symptom.
Outcome
The cmd=0 stepping went from mystery to closed arithmetic; the thermal measurement (hip_roll +20 degC) quantitatively confirmed the 90%-of-heat prediction; the reward change waited for real-world justification instead of spending a risky revision early.
Mechanism
Clock-driven shaping terms define a perpetual-motion bounty unless gated by command; the resulting idle gait is not a training bug but the table's optimum. Its cost surfaces on hardware as stall-torque heating set by statics (mass x lateral offset), which no gain change can remove - only removing the motion (gating) or widening the stance can.
Applies when
- the policy steps in place or creeps at zero command
- specific joints run hot in idle behaviors
- deciding when a known reward flaw justifies a risky mid-lineage fix
“塑形合计 −3.32/步 … 净: 站定亏 42 倍 … 两颗 hip_roll 4.29 / 4.09 N·m(各占限扭 25%),占全机稳态 I²R 的 90% … 吊挂实测 hip_roll 跟踪误差 0.21 rad → 0.0008 rad … 降 kp 救不了热 … 真机不表现该问题, 为真机不存在的病改奖励表不划算”
train/README.md § C1 FAIL 节 (cmd=0 的 sim/真机分歧记账) / C2 真机 A/B 三b 发热定性 No parameter tuning on the floor - a failing config retries once, then it is out; anomalies go back to sim
no-field-tuning-protocolHardware time is for executing and measuring the pre-registered matrix, never for tuning: failing configs get one retry then elimination, anomalies get recorded and reproduced in sim, and contract-check bypass flags stay unused.
Symptom
Hardware sessions create pressure to fix problems live - nudge a gain, tweak a scale - which destroys attribution and risks the robot.
Context
The anomaly-handling section of the acceptance sheet is three fixed plays: (1) falls at start -> retry once at the same settings; falls again -> that configuration is eliminated, "不现场调参" (no on-site parameter tuning); (2) limit cycle or motor screech -> stop immediately, record the gain level and the joint, reproduce in sim before any discussion; (3) systematic disagreement with sim -> record it as a finding (hardware outranks sim) rather than adjusting anything to force agreement. Related guardrails elsewhere in the sheet: never pass --allow-unstamped / --allow-plant-drift to bypass manifest checks - if it errors, something real is wrong, stop and look.
Change
Field sessions restricted to executing the pre-written matrix; every fix path routed through sim reproduction and the normal config/rung process.
Outcome
Sessions stayed interpretable (each run matched a documented config) and safety overrides never became habit; anomalies arrived back in sim as reproducible cases instead of half-remembered floor stories.
Mechanism
Field-tuned values are measured under adrenaline on one floor with no logging or baselines - they contaminate the config lineage and are unattributable afterwards; and every bypass flag that skips a contract check converts a designed safety property into an operator promise.
Applies when
- a config fails or oscillates during a hardware session
- someone reaches for a live gain tweak or a bypass flag
- writing the anomaly-handling section of a deployment runbook
“起步即摔 → 换档重试一次, 仍摔则该档出局, 不现场调参。出现极限环/啸叫 → 立刻停, 记录档位与关节, 回 sim 复现再议。… 不要给 --allow-unstamped / --allow-plant-drift —— 三枚 ONNX 都已盖章 … 真要报错说明有别的问题, 停下来看。”
train/REAL_RUN_S2.md § 4. 异常处置 The real robot's right-leg kicking was over-trained-delay times loop gain - irreducible pipeline latency is plant, model it fully from day one
pipeline-latency-is-plant-not-drMeasure the end-to-end action pipeline delay and build it into the nominal plant and every acceptance gate from day one; treat power/scale deratings that "fix" oscillation as gain-reduction crutches flagging an unmodeled delay, and expect higher-feedback-gain policies to be MORE delay-fragile.
Symptom
On hardware, s1c/s1d at action scale 1.0 always kicked wildly with the right leg (s1c only ran as SOTA at power 0.8; s1d only at 0.7) - while sim showed nothing under default evaluation.
Context
Sim reproduced the incident item by item once the real pipeline delay was injected: s1d@1.0 with --delay 1 fell at 10.2 s, --delay 2 at 5.2 s; s1c@1.0 stressed (r_hip_roll saturation 5 -> 16%; "右脚" = the policy's chirality makes the right leg its high-gain leg); and the combos that worked on hardware (s1c@0.8+delay2, s1d@0.7+delay2) all survived in sim. Mechanism: the real pipeline is ~1-2 ticks (BusWorker next-cycle pickup + CAN round trip) but S1.1 trained only to 1 tick - "超训延迟 × 全环路增益 = 振荡;衰减 = 压环路增益换稳定" (delay beyond training x full loop gain = oscillation; the power derating had been buying stability by compressing loop gain). s1d was MORE fragile than s1c because its yaw 3-layer stack had learned higher feedback gain - higher gain, lower delay tolerance. Three changes: latency DR widened to cover reality; acceptance gates and smoke runs moved permanently to --delay 2 ("门必须在真机条件下预测 真机"); and the doctrine written twice-paid: "不可约的管线属性(延迟、 限速)不是'随机化选项',是 plant 本体,第一天就该全额建模" - S1's nominal-then-robust staging falsified by hardware for the second time. The later s1e hardware run at power 1.0 (no kicking, normal force) closed the loop: "0.8 = 旧代拐杖" - the derating had been a crutch for the under-modeled delay, not a real requirement.
Change
Latency modeled as plant from day one of any lineage (measured 1-2 ticks covered, bridge-layer rate limits likewise modeled by default); every gate and smoke evaluation issued under --delay 2.
Outcome
Kicking reproduced, explained, and eliminated in the s1e generation at full scale and full power; the deploy-side crutches (0.7/0.8) retired for the new lineage.
Mechanism
Feedback oscillation onset is a product of loop gain and phase lag; a policy trained below the real delay learns gains that sit past the real stability margin, and any output derating masks it by scaling gain down. Since pipeline delay is deterministic hardware property - not an uncertainty - it belongs in the nominal plant, and every evaluation must include it or the gate predicts a robot that does not exist.
Applies when
- hardware oscillation/kicking that sim only reproduces with added delay
- a policy only runs on hardware at reduced power/scale
- defining what belongs in the nominal plant vs the DR list
“真实链路延迟 ~1~2 拍 … S1.1 只训到 1 拍——超训延迟 × 全环路增益 = 振荡;衰减 = 压环路增益换稳定。s1d 比 s1c 更脆 = yaw 三层栈学出更高反馈增益,增益越高延迟容忍越低。… 教训入账:S1「先标称后鲁棒」第二次被真机证伪——不可约的管线属性(延迟、限速)不是"随机化选项",是 plant 本体,第一天就该全额建模。”
train/OMNI_V0_SPEC.md § 3. S1.4(真机右脚乱踢事故强制) Every power cycle starts with the same read-only pre-flight - read the buses, check the torque limits against 12/17/11, verify the IMU axes, check the ports after any new USB device - and any reassembly re-measures the joint zeros
power-cycle-preflightStart every powered session with a fixed, read-only pre-flight - bus responses, torque limits equal to the simulated ones, IMU axes, device identities - and re-measure joint zeros after any mechanical reassembly before running a policy.
Symptom
Hardware state drifts between sessions in ways no policy can see: a motor that stops answering after a power cycle, a torque limit that differs from the one simulated, an IMU axis flipped, two USB devices swapping identities, a joint zero moved by reassembly.
Context
The runbook's session order before any policy runs: read every motor on both CAN buses without enabling them (the first command after every power cycle); set_torque --check, all twelve motors must read 12/17/11 N*m, and any difference is written back; imu_reader --verify-axes, where the operator tilts the robot forward and to the right and every check must pass before continuing; check_ports after plugging in any new USB device (the IMU and a CAN adapter once collided on USB identity). After re-mounting motors: read the buses, then re-measure the calibration offsets (three repeats, written back) - "skipping it means running everything on the wrong zero". Hanging checklists repeat the torque-limit check (the deploy script also self-checks at start).
Change
A fixed, read-only pre-flight run in the same order every session.
Outcome
The runbook records one earlier hardware check in the same spirit: all 12 motors' implied kp fell within 18.4-22.0 for a commanded 20, inside the kp randomization range used in training.
Mechanism
A policy transfers only if the plant matches the one it was evaluated on; the pre-flight turns silent hardware drift into a failed check before the robot moves.
Applies when
- the first command after powering a robot on
- after swapping adapters, cables or motors
- a policy that worked last session suddenly behaves differently
“python tools/set_torque.py --check # 12 颗应全对 12/17/11, 有 diff 就 --write … 插任何新 USB 设备后都先跑一次 check_ports.py(IMU 和 CANable 的 USB 身份撞过车) … python tools/calib_stance.py --repeat 3 --write # 重标 offset —— 8/9/10 重新装, 机械零位变了”
RL系统/FOLLOW THIS copy 2.md § WALK / STAND 每次开始前 / 换CAN / 装回后必做两件 The walking lines' safety setting, power-scale 0.8, broke the recovery policy's full-range contract - it cut the ends of the joint travel (4/50 could not get up) and left the torque spikes untouched; a kp x 0.9 gain profile inside the trained kp band did the job
power-derating-cuts-full-range-contractA deployment derating knob means something only relative to the action contract: before reusing a line's "safe setting" on a new skill, check what it does to that skill's reachable range and to the term that makes the spikes, prefer a gain change inside the band the policy was randomized over, verify it in simulation, and re-decide when the contract changes.
Symptom
After the violent first real get-up (2026-08-09), the recovery policy needed a gentler setting for its next hardware test, and the walking and omni lines' standard derating - deploying at power-scale 0.8 - was the obvious candidate.
Context
The V0 recovery contract maps actions to absolute targets over the full joint range: a = +/-1 lands exactly on the URDF limits, and standing puts the knee at the clip. Candidates were compared on R3.1 in MuJoCo (5 categories x 10 seeds) on 2026-08-10 before any hardware time was spent.
Change
A new gain profile, rl_kp090 (kp x 0.9, kd unchanged), recorded in robot.yaml as the recovery hardware-test setting, with power-scale 0.8 explicitly banned for recovery.
Outcome
kp x 0.9: 48/50 got up; median torque demand on hip_pitch/knee fell from 120-125% to 100-104% of the deployment limit; leg-leg contact frames 2,152 -> 1,095; the change sits inside the +/-10% kp randomization the policy trained with. power-scale 0.8: 4/50 could not get up, because under the full-range contract it removes the ends of the travel (the deep squat's tucked legs, the straight standing knee), and the torque spikes (kp x error) did not fall at all. When the line moved to the beta-anchored contract, rl_kp090 was declared a V0-era choice that does not fit (beta is calibrated at kp 30) and deployment returned to rl_default; the deploy switch applies power scaling to the walking side only.
Mechanism
A power scale multiplies the action, which under an absolute full-range mapping shrinks the reachable workspace instead of softening the actuator; the spikes come from the proportional term on large errors, which only a gain change reduces - and a gain change inside the trained randomization band stays in distribution.
Conflicts
The undated operator runbook still carries an R3.1 "B comparison" command at power-scale 0.8 beside the rl_default baseline; the sources do not say whether it was written before the ban or was ever run.
Applies when
- reusing a power, torque or action scale from one skill on another
- a policy whose actions map to absolute targets over the full joint range
- choosing a gentler setting for a first or second hardware trial
“kp×0.9 / kd 不动 —— recovery_r3_1 成功 48/50, τ 需求中位 hip_pitch/knee 120~125% -> 100~104% 部署限, 腿-腿接触 2152 -> 1095 帧; ±10% 在训练 kp DR 带内. ⚠️ power-scale 0.8 对 recovery **禁用**: 全 ROM 契约下 0.8 砍的是行程 端点 (深蹲收腿/站直够不到), 实测 4/50 起不来, 且尖峰 (kp·err) 一点不降 —— 它是 walk/omni 的安全档, 不是 recovery 的.”
git:Lucen-recovery@origin/recovery:robot.yaml § gain_profiles 注释: recovery 真机测试安全档 (2026-08-10) / rl_kp090 Deployment power derating damages non-forward axes far more than forward - sweep it in sim before deploying
power-scale-hurts-nonforward-axesTreat deployment power/torque scaling as a plant parameter: evaluate the policy in sim at the exact deployment scale, expect non-dominant axes to degrade first under derating, and either deploy at the training power or train with power randomization.
Symptom
Policies deployed at power-scale 0.8 (a safety derating of commanded torque) looked fine walking forward but were weak at backward and turning, inviting the wrong diagnosis "the skill was not trained well".
Context
Measured repeatedly: on s1e, going 1.0 -> 0.8 cost forward 18% but backward 58%; on C4-ff800, turn tracking was +25%/+40% at pw0.8 vs +75%/+58% at pw1.0, backward 51-52% vs 97-103%, while forward stayed 96-98% at both. Sim evaluation numbers in the plan were all pw1.0, but the robot was being run at 0.8.
Change
Pre-deploy protocol added: sweep the exported policy across power in sim (for PW in 0.8 0.9 1.0: eval_c_matrix --power $PW --seeds 20) and deploy at the first level where both turn directions reach >=50%. For C4 the recommendation was raise the robot to pw1.0 - the sweep showed it nearly free (saturation 47%->33%, left foot-clipping danger zone 25%->6%, cost only tilt 6.7->8.3 deg).
Outcome
Turning "weakness" resolved without any retraining; the sim sweep correctly predicted the real-robot signature at both power levels.
Mechanism
Forward walking is the reward-dominant, torque-cheapest skill with the most margin; backward/turn/sidewalk live closer to the torque envelope, so a uniform torque derating consumes their margin first. Training ran at power 1.0 (the trainer does no power scaling), so deploying at 0.8 is a systematic underactuation the policy never experienced.
Applies when
- deploying with any torque/power derating or safety scale
- secondary skills (backward, turn, lateral) underperform on hardware while forward walking looks fine
- choosing the deployment power level for a new policy
“power 衰减对非前进轴的伤害远大于前进轴(s1e:前进 1.0→0.8 掉 18%,后退掉 58%)。转向是非前进轴,0.8 下很可能明显跟不动。”
train/C_LADDER_RUN.md § 3c. A-2 上机前先定部署力度档 / 3p. 二 Write each config's expected hardware signature before the session - and if reality disagrees, change the books, not the conclusion
preregistered-real-expectationsBefore hardware runs, write per-config expected signatures and the disagreement rule (hardware outranks sim; discrepancies get recorded, not reconciled); validate the harness by checking it reproduces at least one known real behavior.
Symptom
Hardware impressions are easily narrated after the fact; without written expectations, any real-robot outcome can be made to "match" the sim story.
Context
The S2 acceptance sheet carried a section titled "sim 侧预注册预期 (事后核对, 不许事后改)" - per-configuration behavioral signatures written before the session: s1e@0.8 the disturbance king (push 159/160, zero chirality, all-mu 20/20) at the cost of speed gates 0/20 and zero-command wander ~0.98 m with -29.5 deg/20 s rotation; fric-3000 "walks accurately but is easier to push over"; fric-2400 neither. Credibility check included: the sim harness had reproduced the already-recorded real behavior (pace in place + right drift + net rotation -30 deg/20 s), which "提高本单全部预期的可信度". The anomaly clause fixed the epistemics in advance: if results systematically disagree with sim, "不改结论改账" - don't massage the conclusion, write the discrepancy into the books, and per the earlier zero-warning lesson, hardware wins.
Change
Every hardware session ships with a pre-registered expectation table (signature per config), a baseline-match credibility check, and a written precedence rule for disagreement.
Outcome
The A/B session became falsifiable: agreement confirms the proxy, disagreement is booked as a proxy-bias finding rather than argued away.
Mechanism
Pre-registration converts qualitative hardware sessions into tests of the sim-to-real mapping itself; a reproduced known behavior calibrates trust in the remaining predictions; and fixing "who wins on disagreement" beforehand prevents authority from drifting to whichever source flatters the plan.
Applies when
- planning any hardware acceptance or A/B session
- the sim harness's credibility in this regime is unestablished
- post-session write-ups tempt narrative fitting
“⚠️ sim 复现了真机已记录的「原地踏步 + 右漂 + 净旋 −30°/20s」—— harness 与真机行为对得上, 提高本单全部预期的可信度。… 结果与 sim 系统性不符 → 不改结论改账: 写进 README 该节, 按 「Isaac 指标三次零预警」的教训, 以真机为准。”
train/REAL_RUN_S2.md § 2. sim 侧预注册预期 (事后核对, 不许事后改) / 4. 异常处置 Push-test protocol - positive side first, fragile side spotted, axes aligned in the log, and cross-machine push counts stay qualitative
push-test-chirality-protocolOrder disturbance tests from the robust side to the fragile side with protection scaled to sim-measured asymmetry, align and log frame conventions before testing, and treat cross-domain disturbance counts as qualitative evidence only.
Symptom
Hand-push testing on hardware risked falls on a side sim had already flagged as fragile, and push counts invited apples-to-oranges comparison with sim numbers.
Context
Sim chirality was explicit: descendants were far more fragile in -y (fric-3000@kd1.2: +6 N*s survived 15/20 vs -6 N*s only 3-9/20) while the s1e control was perfectly symmetric (40/40). The protocol therefore: push the positive direction first, keep a spotter for the negative side; before any push, record which real-robot side corresponds to sim's +y in the log ("上机前对一次坐标"); and - citing the chaos lesson ("混沌课文") - real push results are used only as qualitative corroboration, never compared numerically with sim survival counts across machines.
Change
Push testing became a scripted, chirality-aware protocol with frame alignment as a logged precondition and an explicit epistemic limit on cross-domain count comparison.
Outcome
The fragile side was tested with protection informed by sim's quantified asymmetry; logs stayed interpretable because the frame correspondence was recorded before the first push.
Mechanism
Disturbance-response chirality is a real, quantifiable lineage property, so test order should follow measured fragility; and perturbation outcomes are chaotic in the details (divergent trajectories from tiny differences), so counts do not transfer across domains even when qualitative rankings do.
Applies when
- planning push/disturbance tests on hardware
- sim shows directional asymmetry in disturbance survival
- someone proposes comparing real push counts to sim counts
“先正向后负向, 负向留人扶 —— sim 手性明确: 后代在负 y 向显著更脆 (fric-3000 @kd1.2: +6 N·s 15/20 vs −6 N·s 3~9/20), 而 s1e@0.8 两向 40/40 完全对称。上机前对一次坐标 … 跨机不做二值结论 (混沌课文): 真机推力只作定性对照, 不与 sim 计数对比。”
train/REAL_RUN_S2.md § 3. 抗推 (可选, 人手推; 做则按此协议) Fall recovery was defined as the whole chain - any fallen pose, a stable stand, a clean hand-back to walking - and built as a second policy behind a deploy-side switch, not folded into the walking PPO
recovery-two-policies-and-a-state-machineDefine a recovery skill by the whole chain it must complete, including the hand-back to the next controller; if it is built as a separate policy, make the switching logic and its handoff contract a deliverable of their own, and keep the recovery observation contract a subset of the locomotion one so a unified policy stays possible later.
Symptom
A walking robot that falls needs a human to stand it back up. The design question on 2026-08-09 was whether to teach getting up inside the existing omni walking policy or beside it.
Context
The user set the goal as "any fallen pose -> stand up alone -> stand stably", and the spec named the real difficulty as the full chain fall -> recovery -> stable stand -> correctly initialised walking history and clock -> walking, making the deploy state machine a first-class deliverable. A unified single policy had a real-robot precedent (arXiv:2605.18611, a state-dependent gate near 37 deg tilt) but was deferred until a recovery policy and an omni policy were each reliable. The line ran on its own branch and worktree with every walk/stand/omni/run config path untouched. The development path copied the G1 learned get-up logic (arXiv:2502.12152): first find any feasible get-up (ugly accepted), then add smoothing, torque and real-robot constraints. The recovery contract kept the base 45-dim observation (command slice held at 0, no gait phase, no frame history - their reasons do not apply to a skill without a clock or a velocity task), so it stays a prefix of the 215-dim omni contract and a later merge is not foreclosed.
Change
Two policies and a deploy-side switch instead of one retrained walking policy; recovery got its own minimal contract (45 dims, full-range action, later the beta-anchored profile) and its own acceptance battery.
Outcome
The split held for the whole line: on 08-14 deploy_policy gained a second (PolicyIO, ONNX) pair behind --recovery-policy, each loaded under its own manifest contract, and the runbook runs stand_v1b or omni_c4_ff800 as the locomotion side with recovery_v3_1p1c. The literature scan of 08-10 found that every verified get-up implementation deploys one end-to-end policy (or softly gated experts) and stages only on the training side - so the runtime state machine here is the walk/recovery switch, not a staged get-up.
Mechanism
A separate policy keeps each reward table single-purpose and lets a proven walking lineage stay byte-frozen; the cost moves to the handoff, where every piece of state one policy leaves behind (history, clock, last action, command) must be reset for the other.
Applies when
- adding fall recovery or get-up to a robot that already walks
- choosing between one unified policy and a switched pair of policies
- designing the observation/action contract of a secondary skill
“先做 recovery policy + omni policy 两个策略,部署侧状态机切换;不把 recovery 硬塞进现有 omni PPO。 … 任务定义:**任意跌倒姿态 → 自己站起来 → 稳定站立**。真正的难点不只是"起身", … omni walk**(§6 部署状态机是本 spec 的一等公民,不是附录)”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §0 目标口径与架构判决(用户 2026-08-09 定) Removing a foot-spacing wall passed every simulated gate and made the feet collide on the real robot - nothing priced stance width in the two-foot phase, the policy narrowed to the simulator's self-collision floor, and real calibration offsets closed the last millimetres; the wall came back with a gate
removed-wall-returns-on-hardwareWhen a constraint is removed, name what will govern that quantity instead and add a gate for it; never let a simulator's collision floor be the margin, and when a gate is exceeded by a hair, record the exact numbers and hand the release decision to a person instead of quietly passing it.
Symptom
On the first real-robot try of oneleg_v0 (2026-09-16) the two feet collided; the user also judged the folded foot not high enough.
Context
The V0 reward table had dropped the feet_lateral_distance wall because it seemed to conflict with the hip adduction single support needs. In the two-foot command bucket no remaining term governed stance width, so the policy drifted narrower until the simulator's self-collision stopped it; the sim acceptance had no foot-spacing gate, so 40/40 said nothing about it. On the robot, calibration offsets consumed the margin.
Change
V0.1: the wall restored (-10, minimum 0.16 m), re-checked against measured numbers (a swing-phase lateral spacing of ~148 mm costs 0.12 per step, acceptable); fold weight 0.8 -> 2.0; a ninth gate: minimum foot spacing >= 100 mm and zero leg-contact frames. The removal was kept on record.
Outcome
oneleg_v0_1 (V0r2 model_2200) passed 39/40 with the spacing gate 40/40. The single miss (a 15.4 deg tilt transient against a < 15 deg limit during a side switch, steady 6.9 deg, everything else green) was recorded with its numbers and released for the user to overrule.
Mechanism
An unpriced degree of freedom drifts to wherever the simulator stops it; if that stop is the simulator's own collision model, the policy's margin on hardware is whatever the calibration error leaves.
Applies when
- dropping a reward term that looked redundant or conflicting
- hardware shows a failure no simulated gate measures
- a release candidate misses one gate row by a small amount
“V0 撤墙被真机证伪(2026-09-16):双脚桶没有任何项管站宽,策略贴 sim 自碰撞底线收窄,真机标定偏差一吃**双脚相碰**。 … min ≥ 100 mm 且腿碰 0 帧(eval_straight 同判据)—— … V0 真机双脚相碰暴露 sim 门未看脚距的缺口 … L s2 标称 tilt 瞬态 15.4°(门限 <15, 超 0.4°, 稳态 6.9°, 该跑其余全绿)——换侧瞬态蹭线, 判定放行留档, 用户可否决。”
git:Lucen V2@origin/oneleg-line:train/ONELEG_V0_SPEC.md § §4 feet_lateral_distance 行 / §6 验收门 ⑨ / §8 核查单 7 A field experiment is allowed when it is pre-scripted, single-variable, and self-reversing (RAM-only writes)
reversible-single-variable-field-experimentsPermit hardware-side experiments only when scripted in advance with one variable, a log, and automatic reversion (volatile writes, git restore); keep every config mirror (yaml vs firmware) changed and restored as a unit.
Symptom
A hypothesis needed a hardware test - v5's "wild kicking" might trace to the RS00 torque cap being deployed at 11 N*m vs its trained 14 (-21%), on exactly the ankle-roll/hip-yaw joints doing lateral-yaw work - but changing limits in the field is the classic way to lose track of robot state.
Context
The experiment was written to be safe by construction: change exactly one number (robot.yaml RS00 tau_limit 11.0 -> 14.0), write to firmware RAM only (--write without --save, so a power cycle automatically rolls back to the saved 12/17/11), run the single logged trial, then restore both yaml (git checkout) and RAM immediately. The consistency requirement is explicit: the deploy tool's torque self-check compares against robot.yaml, so yaml and firmware must change and restore together; and the hypothesis scoping is itself single-variable - RS06's 67% cut was measured irrelevant (gait uses only 16% of rated) and hip torque was left alone for safety.
Change
Field experimentation policy refined: not "never touch hardware settings" but "only pre-scripted, one-variable, logged, auto-reverting changes with config/firmware kept consistent".
Outcome
The sub-experiment could answer the torque-cap hypothesis without any risk of the robot persisting in an undocumented state - forgetting to restore costs nothing but a git checkout.
Mechanism
The danger of field changes is state divergence (robot config drifting from the repo's record), not the change itself; volatile (RAM-only) writes bound the divergence lifetime to one power cycle, and single-variable scoping preserves attributability even in a field setting.
Applies when
- a hypothesis requires changing firmware limits or gains on the robot
- field debugging tempts persistent config writes
- designing safe escape hatches for deployment tooling
“程序(--write 不带 --save = 只写 RAM,断电自动回滚)… deploy 的限扭自检是对 robot.yaml 比对的,所以 yaml 和固件必须同改同还原;忘了还原也没事,断电重启即回 12/17/11(上次 --save 的值),但 yaml 要 git checkout。”
train/REAL_SWEEP_V5_V8.md § 4. 限扭子实验(可选二期,只对 v5,单变量) Order hardware runs by sim risk, gate each stage on the last, and put the fragile cell last with a spotter
risk-ordered-real-deploymentScript hardware sessions as a risk ladder: baseline first, sim-riskiest last with a spotter, suspended smoke before ground, each stage gated on the previous, environment (floor mu) recorded as a selection input - and stop at the stage that misbehaves.
Symptom
Five policy-x-gain combinations had to go on hardware in one session, with sim survival ranging from 20/20 down to 17/20 (and zero-command survival down to 2/20) - an unordered session risks breaking the robot on an avoidable run.
Context
The execution sheet fixed the order as sim-risk low to high, control baseline first (current SOTA establishes the floor reference), the fragile cell (fric-2400@kd1.0) last with a person spotting throughout. Stage gating: suspended smoke (feet off ground, 10 s each, all five pass before anything touches down) -> suspended with IMU and forward command (gait forms in the air) -> grounded runs -> speed raise only for combos that survived the previous stage -> zero-command tests only with a spotter, ordered by sim zero-cmd survival, with the 2/20 cell skipped by default. Preconditions include recording the floor material and estimating mu (if mu <~0.6, sim says pick the kd1.2 gain as main), port/CAN self-check, calibration frozen. Any stage failing stops the session at that stage: "任一段出问题就停在那一段, 不要跳到下一段".
Change
Session structured as a risk ladder with per-stage gates instead of a flat checklist; per-combo sim survival numbers written into the run table as the ordering key.
Outcome
The session design localized any failure to the cheapest stage that could reveal it, kept the robot safe for the informative fragile run, and made the control baseline available before any comparison run.
Mechanism
Hardware sessions consume a shared budget (robot integrity, battery, floor time); ordering by predicted risk means information is bought cheapest-first, and stage gates convert an expensive failure into a cheap earlier one. Baselines run first because every later reading is relative to them.
Applies when
- taking multiple policies/configs to hardware in one session
- a candidate is known-fragile in sim but must be measured
- writing a deployment runbook for a new robot
“跑序 = sim 风险从低到高, 最险的放最后 (依据 = 存活门/零指令存活) … ⑤ 是 sim 里最脆的一格 … 放最后跑, 全程留人扶, 起步即给 cmd, 零指令不做。… 任一段出问题就停在那一段, 不要跳到下一段。”
train/REAL_RUN_S2.md § 上机名单 / 全部命令 A proposal in the runbook - torque and action limits as versioned safety tiers (classroom / research / expert) written to motor RAM and read back, separate from the reward's effort penalty - recorded as a proposal, its implementation unrecorded
safety-limits-are-a-layer-not-a-rewardKeep hardware limits as an explicit, versioned safety layer (tiers written and read back at start, the persisted default the safest one) and the effort penalty as a behaviour layer; when a skill needs more torque, change tier deliberately rather than trading one layer against the other.
Symptom
Running and jumping need more torque than the deployed limits allow, and the temptation is to trade the training-side effort penalty against the hardware limit, or to hand a new user a robot "tuned however the last person left it".
Context
A message pasted into the operator runbook (undated, citing Berkeley's practice of storing the full motor configuration as JSON with write and read-back scripts) proposes: configuration is a versioned artifact, not a verbal agreement; three safety tiers in robot.yaml beside the gain and policy profiles - classroom (RS06 limited to 10 N*m, lateral joints clamped: "however bad the policy, it only moves awkwardly"), research (14 N*m, clamps at twice the measured need, the default) and expert (the 36 N*m rating, joint limits only, requiring an explicit flag); deploy writes the tier to motor RAM at start and reads it back, while the stored copy stays classroom so a power cut returns to the safest state. It frames limits as the safety layer and the effort penalty as the behaviour layer - more torque for running means switching tier, not weakening the penalty.
Change
None recorded: the message ends by asking which to do first, a rollback or the tiers.
Outcome
The sources do not record the tiers being implemented; the deployed limits stayed at 12/17/11 N*m through the recovery and one-leg lines (the one-leg spec treats raising the RS06 limit as a separate, unapproved hardware decision). Related and recorded elsewhere: torque limits were written to RAM only in a scripted, self-reversing field experiment.
Mechanism
Hardware limits bound the damage any policy can do; reward terms shape what a policy prefers. Mixing them either weakens safety to buy behaviour or distorts behaviour to buy safety.
Applies when
- a new skill needs more torque than the deployed limits
- robots are handed to students or new users
- motor configuration lives in people's heads or in the firmware only
“配置是版本化的产物,不是口头约定。 … deploy_policy 启动时按档写进电机 RAM 并读回校验(落盘的那份永远保持 classroom,断电自动回到最安全状态)。 … 限幅是安全层,dof_torques_l2 是行为塑造层,它们在不同的层,不冲突。跑步要更大力矩就换档,而不是去动训练里的省力惩罚。”
RL系统/FOLLOW THIS copy 2.md § 面向 developer / 教育机构该怎么做 (pasted proposal, undated) A sim veto needs real confirmation too - the worst sim cell was scheduled as the most informative hardware run
sim-veto-needs-real-confirmationNever let sim alone both condemn a purpose-built configuration and escape audit: spend one cheap, safeguarded hardware run on the condemned cell, pre-registering what agreement and disagreement would each imply about the proxy.
Symptom
The fric-2400@kd1.0 combination was sim's worst cell across the board (survival 17/20 - the only miss, mu0.4 1/20, push 103/160, zero-cmd 2/20), yet it was the only product specifically trained for the kd1.0 deployment gain - discarding it on sim evidence alone would leave the sim's own validity untested exactly where it mattered.
Context
The team had been burned in the other direction before ("Isaac 指标三次 零预警" - training-side metrics gave zero warning three times), so the symmetric rule was written: sim's rejection also needs hardware confirmation ("sim 判被支配 ≠ 真机被支配 … sim 的否决也要真机确认"). The run was pre-registered with a dual reading: real matches sim -> the S2f ladder closes and the fork root is settled; real clearly better than sim -> the MuJoCo proxy has a systematic bias in the kd1.0/low-margin region, "那比选型本身重要得多" - and every S2f sim acceptance would need re-scoring.
Change
The condemned configuration was kept on the hardware roster (last, spotted, minimal exposure) explicitly as a proxy-validation probe, not as a deployment candidate.
Outcome
Session design captured either result as progress: selection confirmed, or a proxy bias discovered that would re-price the whole ladder's verdicts.
Mechanism
Every sim verdict is a joint statement about the policy AND the proxy; cells where a policy was purpose-trained for the exact condition sim condemns are where proxy error is most likely and most costly. Testing the veto converts a selection decision into a calibration measurement of the evaluator itself.
Applies when
- sim rejects the configuration that targets the actual deployment condition
- the eval proxy's calibration has never been checked in that regime
- deciding which hardware runs are worth their risk
“但它也是唯一为 kd1.0 部署档专门训的产物 —— sim 判被支配 ≠ 真机被支配, 「Isaac 指标三次零预警」的教训反过来同样成立: sim 的否决也要真机确认。… 若真机明显好于 sim → MuJoCo 代理在 kd1.0/低裕度区有系统性偏差, 那比选型本身重要得多。”
train/REAL_RUN_S2.md § 上机名单 note / 2. sim 侧预注册预期 ⑤ Real-robot trials of a new skill were staged by risk - a hanging dry run with the robot posed by hand, then one short try per category on a mat with the hardest last, then the composed behaviour (switch + walking) last - with the user present and a log every time
staged-hang-mat-floor-for-get-upStage a new skill's hardware trials by risk - hanging dry run posed by hand, one short try on a mat per start category with the hardest last, the composed behaviour last - with an operator ready to cut enable and a log for every try; relax a safety ban only for short, attended runs and say so in writing.
Symptom
A get-up policy acts violently near the ground by design, and the first unstaged real run of the line was stopped as dangerous.
Context
The hanging checklist written with the first stamped recovery product (v2_5, 2026-08-11), to be ticked item by item with the user present: both machines on the same commit and firmware torque limits checked; the robot hung from a single point about 0.1 m off the ground; a dry run with the robot posed by hand into supine and prone to watch that the target stream is gentle (the beta contract keeps targets within +/-0.25 rad of the measured pose, so enabling causes no homing fling); the first floor try is supine only, on a mat, once, with torque and joint logs; categories are added one at a time, prone last; any kicking or oscillation cuts enable immediately. For the switch (08-14) the runbook orders: hang with the standing policy as the locomotion side, then on a mat push the robot over and let it recover, and only last swap in the walking policy. An exemption was also written: edge-standing policies stay banned from long or unattended runs, but a short single A/B with the user present, hung or on a mat, is allowed. The one-leg line reused the same order (hang, then floor with a spotter, 60 s segments with a temperature check).
Change
Real trials as a checklist of stages, each gated on the previous one, with the composed behaviour last.
Outcome
The line's first real get-up (v2_6, 08-11) came through this protocol and was reported "fairly stable"; no further hardware outcomes of the switch are recorded in the spec.
Mechanism
Each stage exposes one new risk (commanded targets without contact, a single category with contact, harder categories, then the interaction of two policies), so a failure is attributable and cheap.
Applies when
- first hardware trial of a recovery, jumping or other high-impact skill
- switching between two policies on hardware for the first time
- a policy with a known posture defect needs a comparison run
“吊挂空跑: 手动摆到 supine/prone 姿态, 看目标流是否温和 (β 帽 7.5 N·m, 目标永远贴着当前 q ±0.25 rad —— 使能瞬间无归位甩动, 这是 β 契约附带保证) … 落地首试: supine 一类, 垫子, 单次; τ/q --log 全程记录 … 逐类别扩展 (prone 最后), 每类先单次”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §40 吊挂执行单(真机首试;需用户在场,逐项打勾) A real-robot verdict is (policy x deployment stack) - when the stack changes materially, old verdicts expire
stale-verdicts-under-old-stackDate every hardware verdict with the deployment-stack version it was measured under; after any material stack change, re-test before trusting old condemnations or old praises - with the interpretation of each possible result written down first.
Symptom
walk_v5 stood condemned as "kicks wildly" and walk_v6 as "cannot walk unassisted" - but those verdicts were issued under an earlier deployment stack (--heading did not exist yet, several fixes had just landed); only v7 had ever run under the current unified stack.
Context
New sim evidence sharpened the doubt: a same-harness four-version sweep showed v6 was the HEALTHIEST archive at the real operating point (cmd 0.15: dominant frequency locked at 2.50, steps 35:35 perfectly symmetric, foot distance 203/190 mm best of four, mean tilt 4.2 deg, saturation 15%). A full re-test under the unified stack was scheduled with per-version questions and a pre-filled interpretation table ("判读表(预填假设,回来对号)"): e.g. v6 walks + frequency ~2.5 -> old verdict was the stack's fault, v6 becomes the comparison champion; v6 walks but at ~1.25 -> period-doubling on hardware = confirmed plant gap, actuator fitting promoted to mainline; v5 no longer kicks -> the kicking was an old-stack artifact.
Change
All four versions re-queued on hardware under one stack (same torque limits, slew profile, heading loop, logging), with the version-specific legacy profile pinned; verdicts held provisional until re-issued.
Outcome
The re-test design separated policy properties from stack artifacts before any policy was permanently written off - and turned each outcome into a specific conclusion via the pre-filled table.
Mechanism
A deployed behavior is produced by the policy plus everything between it and the motors (heading loop, slew limits, torque caps, clock); verdicts implicitly condition on that whole stack. Fixing the stack invalidates the conditioning, so old failures may be stack artifacts and old successes may not survive either.
Applies when
- deployment tooling (limits, filters, loops) changed since a policy was last judged
- deciding which historical policy is the rightful baseline
- a sim sweep contradicts an old hardware verdict
“只有 v7 在完整的今日部署栈下上过真机 … v5"左右乱踢"、v6"未能自主"的判决全部来自更早的栈(--heading 尚不存在, 部分修复刚落地)——判决已过期。且 2026-08-02 四代同机仿真横测翻出了新证据:v6 在真机工况(cmd 0.15)下是四代里最健康的仿真档案”
train/REAL_SWEEP_V5_V8.md § 0. 为什么重测 A stand gate judged by survival passes a robot that wanders a meter - judge posture instead
stand-gate-posture-not-survivalFor every gate, ask what behavior the metric is a proxy for and validate its ordering against real observations; replace metrics whose ordering disagrees with reality, and demote them explicitly rather than silently.
Symptom
Real robot "standing" drifted 0.5-1.4 m across the floor while the sim stand gate scored a clean 20/20 - because the gate's metric was episode survival, which wandering does not violate.
Context
C2's stand condition was originally written as "survival regression <=2/20". A real-robot counter-example on 2026-08-08 forced the re-judgment: wandering robots survive. Cross-checking candidate sim metrics against real-robot feel showed max-tilt median ordering agreed with hands-on ranking, while displacement ordering was actually OPPOSITE to real impressions - so displacement was demoted to a reference quantity, not a gate.
Change
Stand PASS criterion rewritten from survival to posture: "stand tilt max median <= root baseline +1.5 deg"; displacement kept only as reference. Applied to all subsequent rungs (C4 and redo levels inherit it).
Outcome
Later rungs gated stand on tilt (e.g. C4 product: 7.7 deg vs parent 7.1 deg, +0.6 deg PASS); the wandering failure mode became visible to the battery instead of hidden by survival.
Mechanism
A gate metric is a proxy for an intended behavior; survival is a proxy for "did not fall", not "stood still". Metric choice must be validated against ground truth (real-robot feel/measurement), and a proxy whose ordering disagrees with reality on real data is worse than no metric - it steers selection backwards.
Applies when
- writing PASS conditions for stand/idle/hold behaviors
- a gate passes policies that visibly misbehave on hardware
- choosing between candidate metrics for an acceptance battery
“stand 必须用位姿判,不能用存活判(2026-08-08 真机反证改判):站着乱走 0.5~1.4 m 时存活照样 20/20 —— C2 的 stand 条件原写「存活退化 ≤2/20」,选错了指标。改为: stand 倾角 max 中位 ≤ 根基线 +1.5°(倾角与真机手感排序一致;位移排序与真机相反,降为参考量)”
train/C_LADDER_RUN.md § 3b. PASS 条件 ⚠️ stand 必须用位姿判 A suspended (no-load) test acquits or convicts the actuator before you blame authority
suspended-test-isolates-actuator-authorityBefore attributing a failure to actuator authority, measure no-load tracking error and steady-state torque fraction; blame authority only if the task fails while the error grows with demanded force - and then fix gains or targets, not training.
Symptom
hip_roll sagged 0.21 rad on the ground and saturation questions loomed over the sidewalk plan - was the roll axis physically too weak (authority), or was something else limiting it?
Context
Before C4, the roll-authority question was settled by measurement triage: suspended test (--suspend, feet off ground) showed hip_roll tracking error 0.0008 rad - actuator acquitted; the entire 0.21 rad ground sag is load-induced. Steady-state torque was 25% of limit - 75% margin remains. Since sidewalk needs lateral force, not exact angles, authority was ruled "not a hard limit", with a pre-registered criterion for when it WOULD become one: sidewalk fails to track AND roll error keeps growing - then the fix is raising hip_roll kp or lowering the vy target, not more training.
Change
Hypothesis "roll authority insufficient" demoted from blocker to a monitored branch with an explicit trigger condition; C4 proceeded.
Outcome
Later open-loop probes confirmed the actuator could produce the behavior (sidewalk feed-forward ran at full amplitude, 5/5 survival), and the eventual C4 failure causes were measurement and reward, never authority.
Mechanism
Suspended vs loaded comparison separates the actuator's closed-loop competence from the load path: tiny no-load tracking error means the motor/controller is fine and any loaded deviation is statics (gravity / stiffness budget, kp trading error for force). Torque-fraction measurement then bounds how much force headroom actually remains.
Applies when
- suspecting an axis is "too weak" for a new skill
- large position sag on a loaded joint
- deciding between hardware fix, gain change, and more training
“吊挂(--suspend)实测 hip_roll 跟踪误差 0.0008 rad → 执行器无罪,地面下垂 0.21 rad 全是负载所致;稳态占限扭 25% → 仍有 75% 扭矩余量。… 判据:若 C4 出现「侧走跟不动且 roll 误差继续变大」,那才是权限账 … 解法是提 hip_roll 的 kp 或降 vy 目标,不是硬训。”
train/C_LADDER_RUN.md § 3d. roll 权限:已部分澄清,不是硬上限 Add a single-point-suspension test to acceptance - the ground is a free stabilizer that hides divergence
suspension-probe-removes-free-stabilizerInclude at least one acceptance condition that strips the environment's free stabilization (suspension, or equivalent) - the sim-passing policy that fails on hardware is often failing a condition the battery never posed.
Symptom
walk_v5 looked healthy in every on-ground sim test yet diverged on the real robot - the acceptance battery had never measured a condition that would have revealed it.
Context
The battery gained a single-point-suspension probe (robot hung, feet free): measure torso tilt while the policy runs without ground contact. v5 scored 45.9 deg mean tilt suspended - wildly unstable - which the file calls "最灵敏的失稳探针(拿掉地面这个免费稳定器)": ground reaction forces passively stabilize a marginal policy, so on-ground metrics saturate long before the policy's internal balance is actually sound. v6 halved it (23.0 deg, target <10 deg) - progress visible on a scale where on-ground numbers showed nothing.
Change
Suspended-tilt added as a standing acceptance row; run under the honest contact parameters battery (accept_v2 with measured condim 4 / torsional friction 0.035), under which v5 correctly FAILS in agreement with the real robot.
Outcome
The sim battery's verdict on v5 flipped from pass to fail, matching hardware; suspended tilt became the discriminating metric between v5 and v6 (45.9 vs 23.0 deg) when ground metrics differed little.
Mechanism
Contact with the ground closes a stabilizing feedback loop the policy gets for free; removing it exposes the policy's own attitude control authority. A metric measured only in the assisted condition cannot rank policies by the unassisted quantity that hardware will actually demand during perturbations and flight phases.
Applies when
- sim acceptance passes but hardware diverges
- designing an acceptance battery for a legged robot
- two candidates tie on ground metrics
“单点吊那条是最灵敏的失稳探针(拿掉地面这个"免费稳定器"), v5 在地上一切正常却在真机发散, 就是因为验收从没测过这个工况。”
train/WALK_V6_MINIMAL.md § 5. 验收 Foot dragging is an attractor, not a low amplitude - and joint damping is the mode switch, adjustable at deploy time
swing-bistability-damping-switchWhen a quality metric is bimodal, stop treating it as an amplitude to be trained up: map the modes against initial conditions and plant parameters, find the parameter that switches basins, apply it first as a deployment lever, and only then bake it into the training distribution (as a plant-family shift, never as an execution-mapping change).
Symptom
s2e_pd-1400's swing height "median 12.1 mm" hid a perfect bimodal distribution: 20 seeds split into a drag mode (2.6-4.9 mm) and a step mode (19.3-24.0 mm) with NOT ONE seed in between - the median sat in the empty gap, and "swing debt -11 mm" really meant "50% probability of falling into the drag attractor".
Context
Two designed experiments closed the mechanism. Test A (nominal plant, 40 seeds): step 42% / drag 58% / middle 0 - at nominal gains, initial conditions alone pick the mode, both modes 100% survivable. Test B (fixed init, kp x kd grid): kd is the mode SWITCH - at kd 1.3 all surviving cells step (13-22 mm), at kd 0.7 nearly all drag (2.7-4.3), only at kd 1.0 does init get a vote; kp >= 1.2 is dangerous (5/6 falls). Global verification at kd x1.3 (20-seed, delay 2): survival 20/20 at ZERO cost, step share 42 -> 80%, swing median 12.1 -> 18.4 mm, slip record low 334, thicker tilt margin - costs: vx 85 -> 78%, saturation +5 pp. A Pareto sweep then priced the knob: step share 42/72/75/88/82/90 across kd 1.00-1.30 with a linear vx tax of -2.3 pp per 0.1 kd - the basin gain is fully collected at kd 1.20 ("1.30 是 over-damping 纯多付税"). Mechanism: low damping leaves a landing micro-oscillation / ground-slide channel the policy can exploit to drag; damping plugs the channel.
Change
Deployment lever adopted: kd-scale 1.20 (conservative 1.15) as the legitimate successor to the power-0.8 crutch ("前者削幅度保稳,后者堵 拖地通道换步态,且不牺牲存活"); training-side prescription: move the DR band to nominal-1.2 x (0.9,1.1) = [1.08,1.32], deleting the [0.7,1.0) drag-teaching zone - a contract-level change requiring digest re-baselining, gated on measuring the real robot's actual kd dispersion first.
Outcome
The kd surgery rung (s2e_kd) delivered basin 8 -> 11/20, slip 405 -> 331, vx 81 -> 85% with no out-of-band fragility (below-band check 20/20) - "拐杖烧进分布的正确姿势", explicitly contrasted with the failed s1g amplitude version: this one changes the plant family the policy has seen, that one changed the execution mapping the policy would have to relearn.
Mechanism
The gait's swing behavior is a bistable dynamical system whose basin boundaries are set by plant parameters; a policy trained across a kd band that includes the drag basin has learned to inhabit it. Shifting the deployed (and then trained) damping moves the system into the step basin without touching the policy - a plant-side fix for what looked like a training deficiency.
Applies when
- a gait quality metric splits into distinct modes across seeds
- deciding between more training and a gain/damping change
- converting a deployment crutch into a training-distribution change
“20-seed 里拖地模式 2.6~4.9mm 与迈步模式 19.3~24.0mm 各半,中间一个不落 … kd 是模式开关——kd1.3 下 6/6 存活格全迈步 … kd0.7 下几乎全拖地 … swing 债的解(至少大半)在部署端阻尼档,不在训练端 … 机理:低阻尼下落脚微振荡/贴地滑给了策略顺势拖行的通道,加阻尼堵之。”
train/README.md § swing 双稳态定性 + kd 部署杠杆 (2026-08-07, 用户设计 Test A/B) Three same-shaped judging errors - task metrics (survival, tracking, displacement) cannot stand in for posture metrics
task-metrics-vs-posture-metricsKeep validated posture-class rows (tilt, per-joint L/R asymmetry, temperature) in every acceptance battery alongside task rows; when operator feel contradicts the gates, suspect the metric class before the operator - and never build a new skill on what is actually an asymmetry defect.
Symptom
The C2 product judged "full pass" on task metrics (A800: turn-gap 7 pp, vx+0.30 19/20) felt WORSE in the operator's hands than the half-pass 700: A800 tilted up to 12.90 deg (700: 6.64), drifted left while standing, showed larger per-joint asymmetries, and ran its hip_rolls 5 degC hotter.
Context
The re-judgment catalogued three same-type metric errors in one campaign: (1) stand judged by SURVIVAL - missed 0.5-1.4 m wandering; (2) stand ranked by DISPLACEMENT - ordering was opposite to real feel (tilt ordering matched); (3) chirality judged by wz-tracking GAP - measured turning symmetry while the robot's actual disease was postural left/right asymmetry, "两个不同的东西,且结论相反". Common pattern named: "我一直用「任务指标」当判据,而真机手感对应的是「姿态 指标」… 任务类指标不能替代它". The fix was already in the data: the per-joint left/right asymmetry table (printed identically by sim2sim and deploy) agreed with hardware in direction on every row - "判据可用、有预测力,我只是没把它写进 PASS 条件". Shipping decision followed the posture read: product reverted to 700 ("又一次「买到 精度、卖掉别的」"), and the C4 root moved to 700 as well, with the sharpest line of the episode: A800's left-drift "like sidewalking" is probably its frontal-plane asymmetry defect, not a capability - "在缺陷上建能力是危险的".
Change
Two posture quantities with demonstrated real-robot predictive power promoted into every PASS battery: tilt-max median and per-joint left/right asymmetry (both sim-computable, deploy-homologous); motor-temperature readout added to session close-out.
Outcome
Deployment flipped to the posture-better checkpoint; the hip_roll temperature table (43-48 degC vs 25-28) confirmed the earlier 90%-of-heat account; the run-line acceptance battery inherited the posture rows from birth ("任务类替代不了姿态类").
Mechanism
Task metrics measure goal attainment under the evaluator's episode definition; posture metrics measure the body state trajectory that operators, motors, and downstream skills actually experience. The two can rank candidates oppositely because task success tolerates postural pathology - so a battery without posture rows is blind to exactly what hardware feel reports first.
Applies when
- hardware feel disagrees with a green acceptance table
- choosing between checkpoints that split task vs posture metrics
- selecting the root for a skill that resembles an existing defect
“共同模式:我一直用「任务指标」(存活 / 跟踪率 / 位移)当判据,而真机手感对应的是「姿态指标」(倾角、逐关节左右不对称)。→ 验收判据里必须有姿态类指标,任务类指标不能替代它。… A800 的「左飘像 side walk」很可能 … 是它更大的额平面不对称的表现 —— 在缺陷上建能力是危险的。”
train/README.md § C2 选点改判 (2026-08-09): 手性判据第三次选错指标 Teleop fed the sidewalk axis a command beyond its training band - feet clipped; give each axis its own speed setting
teleop-command-band-per-axisGive every command axis its own teleop scale, clamped to that axis's training band, and reproduce any hardware incident in sim with the exact deployed command values before touching training.
Symptom
Robot stepped on its own foot when sidewalking left under teleop - and only when going left.
Context
The teleop tool used one speed setting for all axes: --teleop-speed 0.20 applied to A/D sent cmd_vy = 0.20, above the training band's top (0.08-0.18) where foot-spacing margin is thinnest. Sim reproduction of the incident (product policy, pw0.8, 5 seeds x 20 s, true collision threshold = single foot width 104 mm): at vy 0.20 the minimum foot distance was 111-115 mm - 7-11 mm from self-collision - vs 147 mm at vy 0.10. Left was 4x more dangerous than right (25% vs 6% of time inside the 160 mm soft wall at vy 0.10), matching the left-only symptom; the margin did not degrade over time (pressing more just lengthened exposure).
Change
deploy_policy gained --teleop-side (default 0.10), separating the lateral speed from the forward speed so each axis's teleop command sits inside its own trained band.
Outcome
Command now inside the band with 43 mm margin at default; the incident became a quantified, reproduced, closed account rather than a mystery.
Mechanism
The policy's competence envelope is the training command distribution per axis; teleop mappings that share one scalar across axes silently command out-of-band inputs on the weakest axis. Asymmetric risk (left vs right) came from the policy's own chirality bias, so a symmetric command produced an asymmetric hazard.
Applies when
- wiring a joystick/teleop layer over a learned policy
- a hardware incident occurs on one command direction only
- training bands differ across command axes
“A/D 一直与 W/S 共用速度档,所以按 A 下发的是 vy = 0.20 —— 既超训练带(0.08~0.18)上沿 … 0.20(遥控实际值)| 111~115 mm | 7~11 mm … 且左比右危险 4 倍 … 处置:deploy_policy 新增 --teleop-side(默认 0.10),侧移与前进档分开。”
train/C_LADDER_RUN.md § 3p. 一 向左走踩到自己 → --teleop-speed 0.20 同时喂给了 vy With no term on foot attitude the robot stood on the edges of its feet (ankle roll -26 deg) from R0.5 to V2.5b; pricing it fixed that and turned stance width into the next free variable - the user saw both on video before any metric flagged them
unpriced-foot-attitude-is-a-free-variableList every posture quantity the hardware cares about (foot attitude, stance width, yaw, knee flexion) and make sure each is priced by a term with real gradient at the observed error; pricing one exposes the next, so re-inspect the feet-level video after every change.
Symptom
Watching the v2_5 video the user said the ankle roll after standing looked very strange - the feet were not flat. The feet view showed the right foot standing on its outer edge; median ankle roll at t = 8 s was -/+26 deg (limit +/-35), mirrored. This was the physical form of the ankle_roll saturation criterion that had failed since R0.5.
Context
No term priced foot attitude: feet_contact_upright counts an edge contact as contact, and stand_pose's wide exp kernel (sigma^2 = 9) gives almost no gradient at 0.45 rad. HoST carries an "ankle parallel" term (+20); this table never had one. Edge standing was made a blocking precondition for hardware (continuous ankle load, unstable contact, wear).
Change
V2.6 (single variable): flat_feet = (|q_l_ankle_roll| + |q_r_ankle_roll|) x upright gate x height gate, a linear hinge with a 5 deg margin, weight -2, continued from V2.5b.
Outcome
Ankle roll -/+26 -> 5.3/5.2 deg, ankle_roll saturation 6.6% (< 10%), feet flat on the feet-view video; success 99.6%, re-falls 0-1%. Then the user watched v2_6: hip yaw constantly tense and the legs very close together. The numbers: hip roll -/+4.9/4.8 deg against a nominal 25 - feet flat and hips open 25 deg cannot coexist without ankle compensation, the new term taxed that compensation, and nothing priced stance width. "Foot attitude as a free variable" was fixed and "stance width became the new free variable" - which the real robot then exposed as splits.
Mechanism
An optimizer spends every posture degree of freedom no term prices; closing one reallocates the slack to the next unpriced one.
Applies when
- a standing or landing posture looks wrong on video while gates pass
- a saturation criterion keeps failing on one joint
- a new posture term was just added
“用户看 v2_5 视频:"起身之后 ankle_roll 非常奇怪,脚根本不是平着站立"。 … 机理:奖励表**无任何脚掌姿态项** —— feet_contact_upright 边缘接触也算触地, stand_pose 的 exp 核(σ²=9)对 26°=0.45 rad 梯度≈0。脚掌姿态是自由变量。”
git:Lucen-recovery@origin/recovery:train/RECOVERY_V0_SPEC.md § §41 预注册 V2.6:flat_feet —— ⑥ 老账的物理形态被用户目视锁定